SERIES 7 PERFORMANCE WHITEPAPER




Adaptec Series 7 SAS/SATA RAID Adapters
PCIe Gen3 family of high port count 6Gb/s solutions
with game-changing performance
Introduction
Business and consumer demand for fast and reliable access to       A select group of storage adapters that claim to be designed for
data and content continues to grow. Data centers are faced with    PCIe Gen3 has appeared the market, but most of them max out
the challenge of meeting that demand even as tight budgets         at 8 ports and cannot take full advantage of PCIe Gen3’s superior
force them to reduce the cost of service (COS) per user as well    performance.
as hardware-related Capital Expenses (CapEx) and Operating
Expenses (OpEx).                                                   As we will see, only Adaptec Series 7 SAS/SATA RAID adapters,
                                                                   available with 16 or 24 native SAS/SATA ports, are designed to
Compounding the challenge is the shrinking availability of         fully exploit the high-performance characteristics of PCIe Gen3
physical space — many data centers are unwilling to take on the    (Figure 1).
expense of more real estate and the associated costs that come
from powering and cooling larger spaces.                              8 x 6Gb/s SAS ports     4.8 GB/s
                                                                                                          Bottleneck      16 x 6Gb/s SAS ports    9.6 GB/s

Clearly, the days of simply adding more servers to accommo-
date more traffic are over. As a result, server vendors have
introduced smaller, denser, server chassis sizes that help data
centers add more storage I/O capability while maintaining the
same or a smaller footprint.
Accordingly, storage vendors are focusing on small form-factor                  8 lane PCI Gen3    8 GB/s                       8 lane PCI Gen3   8 GB/s
solutions that will fit into the smaller chassis while providing
the high performance that data centers require. Storage
components, such as hard disk drives, are getting physically                                             Figure 1. PCIe Gen3
smaller (though increasing in capacity). Low-profile storage
adapters are becoming more common as well, but only a select
few are able to deliver top I/O performance and low latency in
                                                                   Significance of high native port count
such a compact form factor. This is an important consideration     In recent years, the storage industry has been transitioning from
for data centers because finding the right combination of form,    3.5-inch storage drives to 2.5-inch Small Form Factor (SSF)
fit and function, allows them to deploy one SKU for almost         drives as advancements in technology allow storage vendors to
any configuration and simplify everything from the purchase        address the aforementioned physical space challenges faced by
decision to installation to maintenance.                           data centers. Not only do SFF drives offer the obvious advantage
                                                                   of allowing more drives to fit into the same server rack space, but
Adaptec Series 7 SAS/SATA RAID adapters address the                2.5-inch drives hold more capacity per space occupied than the
needs of space-challenged modern data centers by doubling          3.5-inch drives they are replacing. Indeed, SFF HDDs now boast
storage performance compared to previous-generation RAID           storage capacities of 1TB or more.
adapters while featuring high port counts and low-profile form
factors that reduce latency, real estate requirements and power    Additionally, the cost of 2.5-inch flash-based solid state drives
consumption.                                                       (SSDs) is finally coming more in line with HDDs in terms of
                                                                   the traditional “cost per GB of capacity” metric. That, combined
The new generation of PCIe                                         with a higher read bandwidth, higher input/output operations
                                                                   per second (IOPs), better mechanical reliability, and higher
PCI Express (PCIe) is a motherboard-mounted expansion              resistance to shock and vibrations compared to HDDs, is driving
bus that, through a connected device such as a RAID adapter,       an industry-wide transition to SSDs.
connects the host system processor to add-on peripherals, such
as storage systems. Introduced into servers and workstations       As the quantity of drives in a server chassis increases, the storage
in 2012, the third generation of PCIe (PCIe Gen3) doubles          adapter card’s port count requirements also increase.
bandwidth to the host compared to its PCIe Gen2 predecessor,
increasing per-lane throughput from 250 MB/s to 500 MB/s.          The traditional method for increasing the storage adapter’s
                                                                   port count has been through the use of an expander — a board
With PCIe Gen2, 8 6Gb/s SAS/SATA ports are sufficient to           that enables the connection of additional attached SAS or
achieve maximum performance. However, PCIe Gen3 requires           SATA devices when the adapter does not have enough ports
a minimum of 16 native 6Gb/s SAS/SATA ports to double the          to accommodate them. However, expanders have a number
bandwidth through the storage connections.
7,000
                                                                                                                                                               7,000
                                                                                                                                  6,000
                                                                                                                                                               6,000                              SERIES 7 PERFORMANCEASRWHITEPAPER
                                                                                                                                                                                                                  24-port 72405
                                                                                                                                                                                                                                    RAID adapter
                                                                                                                                                                                                                                              24-port ASR 72405
                                                                                                                                  5,000                                                                                             (direct connection)
                                                                                                                                                                                                                                              RAID adapter
                                                                                                                                                               5,000                                                                          (direct connection)
                                                                                                                                                                                                                                    8-port Competing RAID adapter
                                                                                                                                  4,000                                                                                             + I/O acceleration software RAID adapter
                                                                                                                                                                                                                                              8-port Competing
                                                                                                                                                               4,000                                                                (using 1 expander)
                       Adaptec Series 7 SAS/SATA RAID Adapters                                                                    3,000
                                                                                                                                                                                                                                              + I/O acceleration software
                                                                                                                                                                                                                                              (using 1 expander)           2
                                                                                                                                                               3,000
                                                                                                                                  2,000
                                                                                                                                                               2,000
                                                                                                                                  1,000
                       of limitations: not only do they add complexity, they also                                                             This problem can be partially overcome if SAS devices are used,
                                                                                                                                                1,000
                       occasionally face compatibility issues with other components                                                          0since they are dual-ported and allow all 8 SAS port connections
                                                                                                                                                      0
                                                                                                                                                  1MB Sequential Reads     1MB Sequential Writes
                       in the storage solution.                                                                                               to be leveraged through the1MB Sequential Writes
                                                                                                                                                        (MB/sec)                    expander. However, as illustrated
                                                                                                                                                          1MB Sequential Reads (MB/sec)
                                                                                                                                                                (MB/sec)                 (MB/sec)
                                                                                                                                              in Figures 4 and 5 below, performance of the 8 6Gb/s SAS
                       On top of that, expanders are notorious for causing latency                                                            ports flattens out at the peak data rate and competing products
                       and limiting data transfer bandwidth. Both of these issues have                                                  Fig 4                  RAID 5 performance (24 SAS SSDs)
                                                                                                                                              cannot match Adaptec 5 performance (24 SAS SSDs)
                                                                                                                                                 Fig 4                 RAID Series 7 speeds.
                       long been tolerated by data centers using HDDs, as they did
                       not cause a huge impact on the already slow read and write
                                                                                                                               600,000
                       speeds of HDDs. But as higher-performance SSDs gain traction                                                  600,000
                       in storage solutions, the latency and bandwidth issues of                                               500,000




                                                                                                             I/Os per second
                                                                                                                                     500,000
                       expanders have become more noticeable, and therefore less




                                                                                                                                 I/Os per second
                                                                                                                               400,000                                                                                                    24-port ASR 72405
                       acceptable.                                                                                                   400,000                                                                                              RAID adapter
                                                                                                                                                                                                                                                    24-port ASR 72405
                                                                                                                                                                                                                                          (direct connection)
                                                                                                                                                                                                                                                    RAID adapter
                                                                                                                               300,000                                                                                                              (direct connection)
                       In a RAID 5 configuration using 24 SATA SSDs (Figure 2),                                                      300,000
                                                                                                                                                                                                                                          8-port Competing RAID
                                                                                                                                                                                                                                          adapter + 8-port Competing RAID
                                                                                                                                                                                                                                                     I/O acceleration
                       the use of expanders causes a roughly 60% performance drop                                              200,000                                                                                                    software (using 1 expander)
                                                                                                                                                                                                                                                    adapter + I/O acceleration
                                                                                                                                                                                                                                                    software (using 1 expander)
                                                                                                                                     200,000
                       on random read IOPs, and a roughly 20% performance drop
                                                                                                                               100,000
                       on OLTP read/write IOPs, compared to a direct connection                                                      100,000
                       through native RAID 5 Random Performance
                                 Fig 2
                                       ports.                                                                                        0
                                                                                                                                       4K Random Reads 4K Random Writes
                                                                                                                                           0                                                                    8K OLTP
                                                                                                                                                                                 (IOPs)Random Reads 4K Random Writes
                                                                                                                                                                                    4K            (IOPs)         (IOPs) 8K OLTP
                                                                                                                                                                                         (IOPs)          (IOPs)          (IOPs)
                  600,000

                  500,000                                                                                                                                                             Figure 4. RAID 5 Performance (24 SAS SSDs)
                                                                                       24-port ASR 72405                                                                                  Fig 5   RAID 5 Sequential Performance
                                                                                       RAID adapter                                                                                                Fig 5 (24 SAS Sequential Performance
                                                                                                                                                                                                          RAID 5 SSDs)
                  400,000                                                              (direct connection)                                                                                                        (24 SAS SSDs)
                                    Fig 2   RAID 5 Random Performance
                                                                                       8-port Competing RAID adapter
                  300,000                                                              + I/O acceleration software
                                                                                       (using 1 expander)                                                      7,000
                                                                                                                                                                                  7,000
                  600,000
                  200,000                                                                                                                                      6,000
                                                                                                                                               MB per second




                                                                                                                                                                                  6,000                                                        24-port ASR 72405
                  500,000
                                                                                                                                                                 MB per second




                  100,000                                                                                                                                      5,000                                                                           RAID adapter
                                                                                                                                                                                                                                                         24-port ASR 72405
                                                                                       24-port ASR 72405                                                                          5,000
                                                                                       RAID adapter                                                                                                                                            (direct connection)
                                                                                                                                                                                                                                                         RAID adapter
                  400,000                                                              (direct connection)                                                     4,000                                                                                     (direct connection)
                                                                                                                                                                                                                                               8-port Competing RAID
                        0                                                                                                                                                         4,000
                          4K Random Reads      4K Random Writes      8K OLTP           8-port Competing RAID adapter                                                                                                                           adapter + 8-port Competing RAID
                                                                                                                                                                                                                                                          I/O acceleration
                               (IOPs)               (IOPs)            (IOPs)           + I/O acceleration software
                                                                                                                                                               3,000                                                                           software (using 1 expander)
                                                                                                                                                                                                                                                         adapter + I/O acceleration
                  300,000                                                                                                                                                         3,000                                                                  software (using 1 expander)
                                                                                       (using 1 expander)
                                                                                                                                                               2,000
                  200,000                                                                                                                                                         2,000
                              Figure Fig 3 RAID 5 Sequential Performance
                                      2. RAID 5 Random Performance (24 SATA SSDs)                                                                              1,000
                  100,000                                                                                                                                                         1,000
                                                                                                                                                                         0
                       Similarly,
                         0         in a RAID 5 configuration with SATA SSDs (Figure                                                                                                   0
                                                                                                                                                                                    1MB Sequential Reads
                                                                                                                                                                                         (MB/sec)
                                                                                                                                                                                                            1MB Sequential Writes
                                                                                                                                                                                           1MB Sequential Reads (MB/sec)
                                                                                                                                                                                                                   1MB Sequential Writes
                    7,000
                       3), theRandom Reads 4K Random Writes a roughly 70% performance drop
                            4K use of expanders cause
                                (IOPs)              (IOPs)
                                                                      8K OLTP
                                                                       (IOPs)
                                                                                                                                                                                                  (MB/sec)                (MB/sec)
                    6,000 sequential read MB/s, and a roughly 40% performance drop
                       on                                                     24-port ASR 72405
                                                                                                                                                                         Figure 5. RAID 5 Sequential Performance (24 SAS SSDs)
                    5,000 sequential write MB/s, compared to a direct connection
                       on                                                     RAID adapter
                                                                              (direct connection)
                       through native ports.
                    4,000
                                       Fig 3 RAID 5 Sequential Performance
                                                                              8-port Competing RAID adapter
                                                                                 + I/O acceleration software
                                                                                 (using 1 expander)
                    3,000                                                                                                                                  Another drawback of expanders is the additional cost they
                    7,000
                    2,000                                                                                                                                  add to a storage solution — about $200 for the expander
                    6,000
                    1,000                                                         24-port ASR 72405                                                        itself plus the cost of cables plus installation, increased power
                    5,000
                                                                                  RAID adapter
                                                                                  (direct connection)
                                                                                                                                                           consumption, and maintenance costs.
                        0
                              1MB Sequential Reads    1MB Sequential Writes       8-port Competing RAID adapter
                    4,000
                                   (MB/sec)                (MB/sec)               + I/O acceleration software                                              An ideal solution for data centers would be a 6Gb/s storage
                                                                                  (using 1 expander)
                    3,000                                                                                                                                  controller with a high native port count that can take advantage
                    2,000                                                                                                                                  of PCIe Gen3’s performance.
                     Fig 4                  RAID 5 performance (24 SAS SSDs)
                    1,000                                                                                                                                  However, as mentioned, most 6Gb/s storage adapters max
                        0                                                                                                                                  out at only 8 ports.
                  600,000     1MB Sequential Reads     1MB Sequential Writes
                                   (MB/sec)                 (MB/sec)
                  500,000
I/Os per second




                             Figure 3. RAID 5 Sequential Performance (24 SATA SSDs)
                  400,000
                     Fig 4                                             24-port ASR 72405
                                            RAID 5 performance (24 SAS SSDs)
                                                                                    RAID adapter
                                                                                    (direct connection)
                  300,000
                                                                                    8-port Competing RAID
                                                                                    adapter + I/O acceleration
                  600,000
                  200,000                                                           software (using 1 expander)

                  500,000
                  100,000
 r second




                  400,000
                        0                                                           24-port ASR 72405
                                                                                    RAID adapter
                             4K Random Reads 4K Random Writes        8K OLTP
SERIES 7 PERFORMANCE WHITEPAPER



Adaptec Series 7 SAS/SATA RAID Adapters                                                                                                                        3


Adaptec Series 7                                                                  Performance comparison
The Adaptec Series 7 SAS/SATA RAID adapter family features                        The following data compares the 24-port PCIe Gen3 Adaptec
PMC’s 24 port PM8015 RAID-on-Chip (ROC), which                                    72405 SAS/SATA RAID adapter to a competing 8-port PCIe
combines an x8 PCIe Gen3 interface with 6Gb/s SAS ports to                        Gen3 RAID adapter.
enable a new generation of high performance, high native port
count RAID adapters that are unmatched by any other ROC in                        Adaptec 72405 performance summary:
the industry.                                                                       • Max Read IOPs observed: 534k IOPs
Traditionally, RAID adapter performance has centered around                           (RAID-0: 24x SSD: Random Read 4KB: Queue Depth = 64)
read and write throughput, measured in megabytes per second                         • Max Write IOPs recorded: 374k IOPs
(MB/s). Using this metric, Series 7 adapters perform up to                            (RAID-0: 24x SSD: Random Write 4KB: Queue Depth = 64)
83% better than competing RAID adapters — 6.6GB/s on
sequential reads and up to 2.6GB/s on sequential writes on                          • Max Read throughput observed: 6400 MB/s
parity RAID 5.                                                                        (RAID-0: 24x SSD: Sequential Read 1MB: Queue Depth = 64)

Moreover, with the popularity and growth of SSDs, input/                            • Max Write throughput observed: 5229 MB/s
output operations per second (IOPs) is emerging as the new                            (RAID-0: 24x SSD: Sequential Write 1MB: Queue Depth = 256)
“lead horse” in performance metrics, with the most common                           • Coalesce Read IOPs performance is observed at: 1.02M IOPs
configuration being the 4K random-read number. Using 4K
                                                                                      (RAID-0: 24x SATA Sequential Read 512B: QD=256)
I/O size in random scenarios is driven by the fact that most
operating systems use 4K cache sizes in the server DRAM                             • Coalesce Write IOPs performance is observed at: 1.07M IOPs
and, with that, 4K is typically the smallest I/O size for random                      (RAID-0: 24x SATA Sequential Write 512B: QD=256)
workloads. In a RAID 5 configuration with 16 direct-connected
SSDs, Series 7 adapters again lead the field with 450K IOPs
— nearly 10x the performance of previous-generation RAID                          Platform:         Intel CanoePass
                                                                                                    Qty. 1x Intel® Intel Xeon 2.9Ghz (8 Cores) (LGA2011)
adapters, and more than double that of the competition.
                                                                                                    2x 4GB (or 8GB total) DDR3-1333Mhz ECC
As noted earlier, RAID adapters with only 8 native ports                          HBA:
cannot pass PCIe Gen3’s performance gains through from                            Cache Mode:       SSD: Logical Read=OFF / Write=OFF / Physical Write=ON
the bus to the storage connections. Adaptec Series 7 RAID                                           SAS/SATA: Logical Read=ON / Write=ON / Physical Write=ON
adapters are the first on the market to take full advantage
                                                                                  ASR 72405         Fw B20104 / Drv B20100
of PCIe Gen3 performance gains by using HD mini-SAS
connectors to offer options with 16 or 24 native SAS/SATA                         Competing         Fw v23.7.0-0035 / Drv v5.2.127.64 / MSM 12.05.03.00
                                                                                  adapter*          * I/O acceleration software, costing additional ~ $150,
ports (Figure 6).
                                                                                                    enabled via Software Key module
                                                                                  Enclosure:        Supermicro SAS216A, 24-bay SAS 6.0Gb/s Passive Backplane
                                                                                                    Supermicro SAS2-216EL2, two independent 24-bay Dual SAS
                                        Expander                                                    6.0Gb/s Expander Backplanes
 16 x 6Gb/s SAS ports
                                        Card:                                                       (Dual SMC expander backplanes needed to avoid SATA
                                        $200+
                                                                                                    performance bottleneck)
                                                                                  Device: Qty 24x
                                                                                  SSD               OCZ Deneva “R” Series SLC: D2RSTK251S14-005 6Gb 50GB
                                                                                                    Fw3.00E
                                                                                  SAS               Seagate Savvio 15K.3: ST9146853SS 6Gb 146GB Fw0002
                  8 x 6Gb/s SAS ports                      16 x 6Gb/s SAS ports
                                                                                  SATA              Seagate Constellation.2: ST9500620NS 6Gb 500GB FwSN02
                                                                                  Software:
                                                                                  OS                Windows 2008 R2 SP1 64bit
                                                                                  IOMETER           Version: 2006.07.27
                                                                                                    Workers: 4
                                                                                                    Workload: SeqRead 512B/1MB, SeqWrite 512B/1MB
                                                                                                    Workload: RndRead 512B/4KB, RndWrite 512B/4KB
                Figure 6. Configuration Complexities and Costs                                       Workload: OLTP 4KB/8KB
                         Expanders vs. Direct Connect
                                                                                                    Ramp/Run: 10sec. / 30sec.
SERIES 7 PERFORMANCE WHITEPAPER



Adaptec Series 7 SAS/SATA RAID Adapters                                                                                                                           4

The following data compares the 24-port PCIe Gen3 Adaptec 72405 SAS/SATA RAID adapter to a competing 8-port PCIe Gen3
RAID adapter.


 RAID – 5 SSD                                                                         Based on Queue Depth = 256
                                                   24-port ASR 72405          Competing 8-port adapter                Competing 8-port adapter (with
                                                   (Direct connection)                                         %        I/O acceleration software)         %
                                                                            (No I/O acceleration software)
 512B Random Reads (IOPs)                               531,580                       163,283                225.6%              373,054                 42.5%
 512B Random Writes (IOPs)                               28,311                        16,771                68.8%                16,759                 68.9%
 4K Random Reads (IOPs)                                 529,731                       163,283                224.4%              377,448                 40.3%
 4K Random Writes (IOPs)                                 28,488                        16,655                71.1%                16,660                 71.0%
 1MB Sequential Reads (MB/s)                              6,192                        3,928                 57.6%                3,904                  58.6%
 1MB Sequential Writes (MB/s)                             2,237                        2,185                  2.4%                2,190                   2.2%

 Note: “%” references the comparison of ASR 72405 over competing product.



 RAID - 10 SSD                                                                        Based on Queue Depth = 256
                                                   24-port ASR 72405          Competing 8-port adapter                Competing 8-port adapter (with
                                                   (Direct connection)                                         %        I/O acceleration software)         %
                                                                            (No I/O acceleration software)
 512B Random Reads (IOPs)                               534,824                       170,338                214.0%              373,396                 43.2%
 512B Random Writes (IOPs)                              130,851                        43,901                198.1%               43,752                 199.1%
 4K Random Reads (IOPs)                                 535,546                       170,092                214.9%              364,165                 47.1%
 4K Random Writes (IOPs)                                192,051                        43,808                338.4%               43,508                 341.4%
 1MB Sequential Reads (MB/s)                              5,433                        3,911                 38.9%                3,888                  39.7%
 1MB Sequential Writes (MB/s)                             2,892                        1,418                 104.0%               1,404                  106.0%

 Note: “%” references the comparison of ASR 72405 over competing product.



 RAID – 0 SSD                                                                         Based on Queue Depth = 256
                                                   24-port ASR 72405          Competing 8-port adapter                   Competing 8-port adapter
                                                   (Direct connection)      (No I/O acceleration software)     %      (with I/O acceleration software)     %

 512B Random Reads (IOPs)                               531,852                       169,822                213.2%              375,676                 41.6%
 512B Random Writes (IOPs)                              238,681                       166,875                43.0%               352,385                 -32.3%
 4K Random Reads (IOPs)                                 527,425                       170,024                210.2%              377,964                 39.5%
 4K Random Writes (IOPs)                                245,327                       166,803                47.1%               295,252                 -16.9%
 1MB Sequential Reads (MB/s)                              6,182                        3,467                 78.3%                3,435                  80.0%
 1MB Sequential Writes (MB/s)                             5,229                        2,790                 87.5%                2,751                  90.1%

 Note: “%” references the comparison of ASR 72405 over competing product.
SERIES 7 PERFORMANCE WHITEPAPER



Adaptec Series 7 SAS/SATA RAID Adapters                                                                                                                                                 5


Conclusion
In order to continue meeting customer demand for fast and
reliable access to data and content, data centers must employ
efficient storage solutions that maximize I/O capability while
fitting within budgetary and physical space requirements.

A new generation of PCIe Gen3 storage adapters seek to
enhance storage I/O performance, but only Adaptec Series 7
SAS/SATA RAID adapters fully address the needs of space-
challenged modern data centers by offering 16 ports required
to maximize PCIe Gen3 performance.

Series 7 adapters perform up to 83% better than competing
RAID adapters in read and write throughput — 6.6 GB/s on
sequential reads and up to 2.6 GB/s on sequential writes on
parity RAID 5 — and lead the field with 450K IOPs — nearly
10x the performance of previous-generation RAID adapters,
and more than double that of the competition.




PMC-Sierra, Inc.
1380 Bordeaux Dr.                      World Wide Web: www.adaptec.com
Sunnyvale, CA 94089 USA	               Pre-Sales Support:	 US and Canada: 1 (800) 442-7274 or (408) 957-7274 or adaptecsales@pmc-sierra.com
Tel: +1 (408) 239-8000                 	                   UK: +44 1276 854 528 or uk_sales@pmc-sierra.com
                                       	                   Australia: +61-2- 90116787
                                       	                   Singapore: +65-92351044
© Copyright PMC-Sierra, Inc. 2012. All rights reserved. PMC, PMC-SIERRA and Adaptec are registered trademarks of PMC-Sierra, Inc. “Adaptec by PMC” is a trademark of PMC-Sierra, Inc.
Other product and company names mentioned herein may be trademarks of their respective owners. For a complete list of PMC-Sierra trademarks, see www.pmc-sierra.com/legal.
WP_SERIES7PERF_100212_US         Information subject to change without notice.

Contenu connexe

En vedette

Tues exploration pre quiz + columbus
Tues exploration pre quiz + columbusTues exploration pre quiz + columbus
Tues exploration pre quiz + columbusTravis Klein
 
Risk Intelligence: Harnessing Risk, Exploiting Opportunity
Risk Intelligence: Harnessing Risk, Exploiting OpportunityRisk Intelligence: Harnessing Risk, Exploiting Opportunity
Risk Intelligence: Harnessing Risk, Exploiting OpportunityEMC
 
Data Protection Priorities and Challenges
Data Protection Priorities and ChallengesData Protection Priorities and Challenges
Data Protection Priorities and ChallengesEMC
 
Informe consulta devoluciones
Informe consulta devolucionesInforme consulta devoluciones
Informe consulta devolucionesNathalia Sanchez
 
Dubravka Granulic tm_regional2
Dubravka Granulic tm_regional2Dubravka Granulic tm_regional2
Dubravka Granulic tm_regional2Dubravka Granulić
 
Get hydrated
Get hydratedGet hydrated
Get hydratedsloeb
 
SME Estudio Marcas que Marcan 2012
SME Estudio Marcas que Marcan 2012SME Estudio Marcas que Marcan 2012
SME Estudio Marcas que Marcan 2012SME Puerto Rico
 
Insaat kursu-beykoz
Insaat kursu-beykozInsaat kursu-beykoz
Insaat kursu-beykozsersld54
 
Supply demand issues
Supply demand issuesSupply demand issues
Supply demand issuesTravis Klein
 
MIFARE ClassicのAccess Conditions
MIFARE ClassicのAccess ConditionsMIFARE ClassicのAccess Conditions
MIFARE ClassicのAccess ConditionsHirokuma Ueno
 
Flash-Specific Data Protection
Flash-Specific Data ProtectionFlash-Specific Data Protection
Flash-Specific Data ProtectionEMC
 
Formulario agenda telefonica
Formulario agenda telefonicaFormulario agenda telefonica
Formulario agenda telefonicaNathalia Sanchez
 
Zipcar For Business Meet Your New Company Car
Zipcar For Business   Meet Your New Company CarZipcar For Business   Meet Your New Company Car
Zipcar For Business Meet Your New Company CarCharlotte Gatehouse
 

En vedette (20)

Tues exploration pre quiz + columbus
Tues exploration pre quiz + columbusTues exploration pre quiz + columbus
Tues exploration pre quiz + columbus
 
Risk Intelligence: Harnessing Risk, Exploiting Opportunity
Risk Intelligence: Harnessing Risk, Exploiting OpportunityRisk Intelligence: Harnessing Risk, Exploiting Opportunity
Risk Intelligence: Harnessing Risk, Exploiting Opportunity
 
Data Protection Priorities and Challenges
Data Protection Priorities and ChallengesData Protection Priorities and Challenges
Data Protection Priorities and Challenges
 
Informe consulta devoluciones
Informe consulta devolucionesInforme consulta devoluciones
Informe consulta devoluciones
 
Dubravka Granulic tm_regional2
Dubravka Granulic tm_regional2Dubravka Granulic tm_regional2
Dubravka Granulic tm_regional2
 
Get hydrated
Get hydratedGet hydrated
Get hydrated
 
SME Estudio Marcas que Marcan 2012
SME Estudio Marcas que Marcan 2012SME Estudio Marcas que Marcan 2012
SME Estudio Marcas que Marcan 2012
 
Batatgal
BatatgalBatatgal
Batatgal
 
Insaat kursu-beykoz
Insaat kursu-beykozInsaat kursu-beykoz
Insaat kursu-beykoz
 
Finance
FinanceFinance
Finance
 
Drop the Pressure on your Production Server
Drop the Pressure on your Production ServerDrop the Pressure on your Production Server
Drop the Pressure on your Production Server
 
Supply demand issues
Supply demand issuesSupply demand issues
Supply demand issues
 
Externalities
ExternalitiesExternalities
Externalities
 
Mon build factory
Mon build factoryMon build factory
Mon build factory
 
Cvpw
CvpwCvpw
Cvpw
 
MIFARE ClassicのAccess Conditions
MIFARE ClassicのAccess ConditionsMIFARE ClassicのAccess Conditions
MIFARE ClassicのAccess Conditions
 
Flash-Specific Data Protection
Flash-Specific Data ProtectionFlash-Specific Data Protection
Flash-Specific Data Protection
 
Formulario agenda telefonica
Formulario agenda telefonicaFormulario agenda telefonica
Formulario agenda telefonica
 
Beautiful
BeautifulBeautiful
Beautiful
 
Zipcar For Business Meet Your New Company Car
Zipcar For Business   Meet Your New Company CarZipcar For Business   Meet Your New Company Car
Zipcar For Business Meet Your New Company Car
 

Similaire à Series7 Performance Whitepaper

Adaptec by PMC Series 7 Adapters
Adaptec by PMC Series 7 AdaptersAdaptec by PMC Series 7 Adapters
Adaptec by PMC Series 7 AdaptersAdaptec by PMC
 
Adaptec 12Gb/s SAS Expander Card
Adaptec 12Gb/s SAS Expander CardAdaptec 12Gb/s SAS Expander Card
Adaptec 12Gb/s SAS Expander CardAdaptec by PMC
 
Series 8 RAID Datasheet
Series 8 RAID DatasheetSeries 8 RAID Datasheet
Series 8 RAID DatasheetAdaptec by PMC
 
Adaptec RAID 81605ZQ vs. LSI MegaRAID 9361-8i Performance Whitepaper
Adaptec RAID 81605ZQ vs. LSI MegaRAID 9361-8i Performance WhitepaperAdaptec RAID 81605ZQ vs. LSI MegaRAID 9361-8i Performance Whitepaper
Adaptec RAID 81605ZQ vs. LSI MegaRAID 9361-8i Performance WhitepaperAdaptec by PMC
 
Sun storage tek 2500 series disk array technical presentation
Sun storage tek 2500 series disk array technical presentationSun storage tek 2500 series disk array technical presentation
Sun storage tek 2500 series disk array technical presentationxKinAnx
 
Adaptec’s maxCache™ 3.0 Read and Write SSD Caching Solution
Adaptec’s maxCache™ 3.0 Read and Write SSD Caching SolutionAdaptec’s maxCache™ 3.0 Read and Write SSD Caching Solution
Adaptec’s maxCache™ 3.0 Read and Write SSD Caching SolutionAdaptec by PMC
 
Adaptec Series 7He Host Bus Adapters Datasheet
Adaptec Series 7He Host Bus Adapters DatasheetAdaptec Series 7He Host Bus Adapters Datasheet
Adaptec Series 7He Host Bus Adapters DatasheetAdaptec by PMC
 
Adaptec by PMC Series 6H Host Bus Adapters Datasheet
Adaptec by PMC Series 6H Host Bus Adapters DatasheetAdaptec by PMC Series 6H Host Bus Adapters Datasheet
Adaptec by PMC Series 6H Host Bus Adapters DatasheetAdaptec by PMC
 
PM8056 Chip SAS Expander from PMC Sierra
PM8056 Chip SAS Expander from PMC Sierra PM8056 Chip SAS Expander from PMC Sierra
PM8056 Chip SAS Expander from PMC Sierra Devanshu Shrivastava
 
NVMe Takes It All, SCSI Has To Fall
NVMe Takes It All, SCSI Has To FallNVMe Takes It All, SCSI Has To Fall
NVMe Takes It All, SCSI Has To Fallinside-BigData.com
 
Storage Performance Takes Off
Storage Performance Takes OffStorage Performance Takes Off
Storage Performance Takes OffIT Brand Pulse
 
Optimizing Hadoop Deployments with AMD/SeaMicro SM15000 Fabric Servers
Optimizing Hadoop Deployments with AMD/SeaMicro SM15000 Fabric ServersOptimizing Hadoop Deployments with AMD/SeaMicro SM15000 Fabric Servers
Optimizing Hadoop Deployments with AMD/SeaMicro SM15000 Fabric ServersSatheesh Nanniyur
 
CC-4009, "Optimizing Hadoop Deployments with SeaMicro SM15000" by Satheesh Na...
CC-4009, "Optimizing Hadoop Deployments with SeaMicro SM15000" by Satheesh Na...CC-4009, "Optimizing Hadoop Deployments with SeaMicro SM15000" by Satheesh Na...
CC-4009, "Optimizing Hadoop Deployments with SeaMicro SM15000" by Satheesh Na...AMD Developer Central
 
JetStor 8 series 16G FC 12G SAS units
JetStor 8 series 16G FC 12G SAS unitsJetStor 8 series 16G FC 12G SAS units
JetStor 8 series 16G FC 12G SAS unitsGene Leyzarovich
 
Achieve more storage performance with Dell PowerEdge R750 servers equipped wi...
Achieve more storage performance with Dell PowerEdge R750 servers equipped wi...Achieve more storage performance with Dell PowerEdge R750 servers equipped wi...
Achieve more storage performance with Dell PowerEdge R750 servers equipped wi...Principled Technologies
 
PLX Technology Company Overview
PLX Technology Company OverviewPLX Technology Company Overview
PLX Technology Company OverviewPLX Technology
 
Unlock more mixed storage performance on Dell PowerEdge R750 servers with Bro...
Unlock more mixed storage performance on Dell PowerEdge R750 servers with Bro...Unlock more mixed storage performance on Dell PowerEdge R750 servers with Bro...
Unlock more mixed storage performance on Dell PowerEdge R750 servers with Bro...Principled Technologies
 

Similaire à Series7 Performance Whitepaper (20)

Adaptec by PMC Series 7 Adapters
Adaptec by PMC Series 7 AdaptersAdaptec by PMC Series 7 Adapters
Adaptec by PMC Series 7 Adapters
 
Adaptec 12Gb/s SAS Expander Card
Adaptec 12Gb/s SAS Expander CardAdaptec 12Gb/s SAS Expander Card
Adaptec 12Gb/s SAS Expander Card
 
Series 8 RAID Datasheet
Series 8 RAID DatasheetSeries 8 RAID Datasheet
Series 8 RAID Datasheet
 
Adaptec RAID 81605ZQ vs. LSI MegaRAID 9361-8i Performance Whitepaper
Adaptec RAID 81605ZQ vs. LSI MegaRAID 9361-8i Performance WhitepaperAdaptec RAID 81605ZQ vs. LSI MegaRAID 9361-8i Performance Whitepaper
Adaptec RAID 81605ZQ vs. LSI MegaRAID 9361-8i Performance Whitepaper
 
Sun storage tek 2500 series disk array technical presentation
Sun storage tek 2500 series disk array technical presentationSun storage tek 2500 series disk array technical presentation
Sun storage tek 2500 series disk array technical presentation
 
Adaptec’s maxCache™ 3.0 Read and Write SSD Caching Solution
Adaptec’s maxCache™ 3.0 Read and Write SSD Caching SolutionAdaptec’s maxCache™ 3.0 Read and Write SSD Caching Solution
Adaptec’s maxCache™ 3.0 Read and Write SSD Caching Solution
 
Adaptec Series 7He Host Bus Adapters Datasheet
Adaptec Series 7He Host Bus Adapters DatasheetAdaptec Series 7He Host Bus Adapters Datasheet
Adaptec Series 7He Host Bus Adapters Datasheet
 
Adaptec by PMC Series 6H Host Bus Adapters Datasheet
Adaptec by PMC Series 6H Host Bus Adapters DatasheetAdaptec by PMC Series 6H Host Bus Adapters Datasheet
Adaptec by PMC Series 6H Host Bus Adapters Datasheet
 
PM8056 Chip SAS Expander from PMC Sierra
PM8056 Chip SAS Expander from PMC Sierra PM8056 Chip SAS Expander from PMC Sierra
PM8056 Chip SAS Expander from PMC Sierra
 
HP StorageWorks
HP StorageWorksHP StorageWorks
HP StorageWorks
 
Adaptec maxCache 3.0
Adaptec maxCache 3.0Adaptec maxCache 3.0
Adaptec maxCache 3.0
 
NVMe Takes It All, SCSI Has To Fall
NVMe Takes It All, SCSI Has To FallNVMe Takes It All, SCSI Has To Fall
NVMe Takes It All, SCSI Has To Fall
 
Storage Performance Takes Off
Storage Performance Takes OffStorage Performance Takes Off
Storage Performance Takes Off
 
Optimizing Hadoop Deployments with AMD/SeaMicro SM15000 Fabric Servers
Optimizing Hadoop Deployments with AMD/SeaMicro SM15000 Fabric ServersOptimizing Hadoop Deployments with AMD/SeaMicro SM15000 Fabric Servers
Optimizing Hadoop Deployments with AMD/SeaMicro SM15000 Fabric Servers
 
CC-4009, "Optimizing Hadoop Deployments with SeaMicro SM15000" by Satheesh Na...
CC-4009, "Optimizing Hadoop Deployments with SeaMicro SM15000" by Satheesh Na...CC-4009, "Optimizing Hadoop Deployments with SeaMicro SM15000" by Satheesh Na...
CC-4009, "Optimizing Hadoop Deployments with SeaMicro SM15000" by Satheesh Na...
 
JetStor 8 series 16G FC 12G SAS units
JetStor 8 series 16G FC 12G SAS unitsJetStor 8 series 16G FC 12G SAS units
JetStor 8 series 16G FC 12G SAS units
 
Achieve more storage performance with Dell PowerEdge R750 servers equipped wi...
Achieve more storage performance with Dell PowerEdge R750 servers equipped wi...Achieve more storage performance with Dell PowerEdge R750 servers equipped wi...
Achieve more storage performance with Dell PowerEdge R750 servers equipped wi...
 
PLX Technology Company Overview
PLX Technology Company OverviewPLX Technology Company Overview
PLX Technology Company Overview
 
Unlock more mixed storage performance on Dell PowerEdge R750 servers with Bro...
Unlock more mixed storage performance on Dell PowerEdge R750 servers with Bro...Unlock more mixed storage performance on Dell PowerEdge R750 servers with Bro...
Unlock more mixed storage performance on Dell PowerEdge R750 servers with Bro...
 
San Presentation
San PresentationSan Presentation
San Presentation
 

Plus de Adaptec by PMC

Data Center Blueprints: Open Compute
Data Center Blueprints: Open ComputeData Center Blueprints: Open Compute
Data Center Blueprints: Open ComputeAdaptec by PMC
 
Adaptec by PMC Zero-Maintenance Cache Protection (ZMCP)
Adaptec by PMC Zero-Maintenance Cache Protection (ZMCP)Adaptec by PMC Zero-Maintenance Cache Protection (ZMCP)
Adaptec by PMC Zero-Maintenance Cache Protection (ZMCP)Adaptec by PMC
 
Introduction to Zero-Maintenance Cache Protection
Introduction to Zero-Maintenance Cache ProtectionIntroduction to Zero-Maintenance Cache Protection
Introduction to Zero-Maintenance Cache ProtectionAdaptec by PMC
 
Adaptec Hybrid RAID Whitepaper
Adaptec Hybrid RAID WhitepaperAdaptec Hybrid RAID Whitepaper
Adaptec Hybrid RAID WhitepaperAdaptec by PMC
 
Adaptec Flash Module 600 Datasheet
Adaptec Flash Module 600 DatasheetAdaptec Flash Module 600 Datasheet
Adaptec Flash Module 600 DatasheetAdaptec by PMC
 
Introduction to Intelligent Power Management
Introduction to Intelligent Power ManagementIntroduction to Intelligent Power Management
Introduction to Intelligent Power ManagementAdaptec by PMC
 

Plus de Adaptec by PMC (9)

Data Center Blueprints: Open Compute
Data Center Blueprints: Open ComputeData Center Blueprints: Open Compute
Data Center Blueprints: Open Compute
 
Adaptec Hybrid RAID
Adaptec Hybrid RAIDAdaptec Hybrid RAID
Adaptec Hybrid RAID
 
Adaptec by PMC Zero-Maintenance Cache Protection (ZMCP)
Adaptec by PMC Zero-Maintenance Cache Protection (ZMCP)Adaptec by PMC Zero-Maintenance Cache Protection (ZMCP)
Adaptec by PMC Zero-Maintenance Cache Protection (ZMCP)
 
AFM-700 Datasheet
AFM-700 DatasheetAFM-700 Datasheet
AFM-700 Datasheet
 
Introduction to RAID
Introduction to RAIDIntroduction to RAID
Introduction to RAID
 
Introduction to Zero-Maintenance Cache Protection
Introduction to Zero-Maintenance Cache ProtectionIntroduction to Zero-Maintenance Cache Protection
Introduction to Zero-Maintenance Cache Protection
 
Adaptec Hybrid RAID Whitepaper
Adaptec Hybrid RAID WhitepaperAdaptec Hybrid RAID Whitepaper
Adaptec Hybrid RAID Whitepaper
 
Adaptec Flash Module 600 Datasheet
Adaptec Flash Module 600 DatasheetAdaptec Flash Module 600 Datasheet
Adaptec Flash Module 600 Datasheet
 
Introduction to Intelligent Power Management
Introduction to Intelligent Power ManagementIntroduction to Intelligent Power Management
Introduction to Intelligent Power Management
 

Dernier

08448380779 Call Girls In Civil Lines Women Seeking Men
08448380779 Call Girls In Civil Lines Women Seeking Men08448380779 Call Girls In Civil Lines Women Seeking Men
08448380779 Call Girls In Civil Lines Women Seeking MenDelhi Call girls
 
Exploring the Future Potential of AI-Enabled Smartphone Processors
Exploring the Future Potential of AI-Enabled Smartphone ProcessorsExploring the Future Potential of AI-Enabled Smartphone Processors
Exploring the Future Potential of AI-Enabled Smartphone Processorsdebabhi2
 
Tata AIG General Insurance Company - Insurer Innovation Award 2024
Tata AIG General Insurance Company - Insurer Innovation Award 2024Tata AIG General Insurance Company - Insurer Innovation Award 2024
Tata AIG General Insurance Company - Insurer Innovation Award 2024The Digital Insurer
 
Histor y of HAM Radio presentation slide
Histor y of HAM Radio presentation slideHistor y of HAM Radio presentation slide
Histor y of HAM Radio presentation slidevu2urc
 
Developing An App To Navigate The Roads of Brazil
Developing An App To Navigate The Roads of BrazilDeveloping An App To Navigate The Roads of Brazil
Developing An App To Navigate The Roads of BrazilV3cube
 
Kalyanpur ) Call Girls in Lucknow Finest Escorts Service 🍸 8923113531 🎰 Avail...
Kalyanpur ) Call Girls in Lucknow Finest Escorts Service 🍸 8923113531 🎰 Avail...Kalyanpur ) Call Girls in Lucknow Finest Escorts Service 🍸 8923113531 🎰 Avail...
Kalyanpur ) Call Girls in Lucknow Finest Escorts Service 🍸 8923113531 🎰 Avail...gurkirankumar98700
 
Partners Life - Insurer Innovation Award 2024
Partners Life - Insurer Innovation Award 2024Partners Life - Insurer Innovation Award 2024
Partners Life - Insurer Innovation Award 2024The Digital Insurer
 
Neo4j - How KGs are shaping the future of Generative AI at AWS Summit London ...
Neo4j - How KGs are shaping the future of Generative AI at AWS Summit London ...Neo4j - How KGs are shaping the future of Generative AI at AWS Summit London ...
Neo4j - How KGs are shaping the future of Generative AI at AWS Summit London ...Neo4j
 
Handwritten Text Recognition for manuscripts and early printed texts
Handwritten Text Recognition for manuscripts and early printed textsHandwritten Text Recognition for manuscripts and early printed texts
Handwritten Text Recognition for manuscripts and early printed textsMaria Levchenko
 
Injustice - Developers Among Us (SciFiDevCon 2024)
Injustice - Developers Among Us (SciFiDevCon 2024)Injustice - Developers Among Us (SciFiDevCon 2024)
Injustice - Developers Among Us (SciFiDevCon 2024)Allon Mureinik
 
Finology Group – Insurtech Innovation Award 2024
Finology Group – Insurtech Innovation Award 2024Finology Group – Insurtech Innovation Award 2024
Finology Group – Insurtech Innovation Award 2024The Digital Insurer
 
From Event to Action: Accelerate Your Decision Making with Real-Time Automation
From Event to Action: Accelerate Your Decision Making with Real-Time AutomationFrom Event to Action: Accelerate Your Decision Making with Real-Time Automation
From Event to Action: Accelerate Your Decision Making with Real-Time AutomationSafe Software
 
[2024]Digital Global Overview Report 2024 Meltwater.pdf
[2024]Digital Global Overview Report 2024 Meltwater.pdf[2024]Digital Global Overview Report 2024 Meltwater.pdf
[2024]Digital Global Overview Report 2024 Meltwater.pdfhans926745
 
The Role of Taxonomy and Ontology in Semantic Layers - Heather Hedden.pdf
The Role of Taxonomy and Ontology in Semantic Layers - Heather Hedden.pdfThe Role of Taxonomy and Ontology in Semantic Layers - Heather Hedden.pdf
The Role of Taxonomy and Ontology in Semantic Layers - Heather Hedden.pdfEnterprise Knowledge
 
CNv6 Instructor Chapter 6 Quality of Service
CNv6 Instructor Chapter 6 Quality of ServiceCNv6 Instructor Chapter 6 Quality of Service
CNv6 Instructor Chapter 6 Quality of Servicegiselly40
 
Driving Behavioral Change for Information Management through Data-Driven Gree...
Driving Behavioral Change for Information Management through Data-Driven Gree...Driving Behavioral Change for Information Management through Data-Driven Gree...
Driving Behavioral Change for Information Management through Data-Driven Gree...Enterprise Knowledge
 
Mastering MySQL Database Architecture: Deep Dive into MySQL Shell and MySQL R...
Mastering MySQL Database Architecture: Deep Dive into MySQL Shell and MySQL R...Mastering MySQL Database Architecture: Deep Dive into MySQL Shell and MySQL R...
Mastering MySQL Database Architecture: Deep Dive into MySQL Shell and MySQL R...Miguel Araújo
 
Axa Assurance Maroc - Insurer Innovation Award 2024
Axa Assurance Maroc - Insurer Innovation Award 2024Axa Assurance Maroc - Insurer Innovation Award 2024
Axa Assurance Maroc - Insurer Innovation Award 2024The Digital Insurer
 
2024: Domino Containers - The Next Step. News from the Domino Container commu...
2024: Domino Containers - The Next Step. News from the Domino Container commu...2024: Domino Containers - The Next Step. News from the Domino Container commu...
2024: Domino Containers - The Next Step. News from the Domino Container commu...Martijn de Jong
 
A Domino Admins Adventures (Engage 2024)
A Domino Admins Adventures (Engage 2024)A Domino Admins Adventures (Engage 2024)
A Domino Admins Adventures (Engage 2024)Gabriella Davis
 

Dernier (20)

08448380779 Call Girls In Civil Lines Women Seeking Men
08448380779 Call Girls In Civil Lines Women Seeking Men08448380779 Call Girls In Civil Lines Women Seeking Men
08448380779 Call Girls In Civil Lines Women Seeking Men
 
Exploring the Future Potential of AI-Enabled Smartphone Processors
Exploring the Future Potential of AI-Enabled Smartphone ProcessorsExploring the Future Potential of AI-Enabled Smartphone Processors
Exploring the Future Potential of AI-Enabled Smartphone Processors
 
Tata AIG General Insurance Company - Insurer Innovation Award 2024
Tata AIG General Insurance Company - Insurer Innovation Award 2024Tata AIG General Insurance Company - Insurer Innovation Award 2024
Tata AIG General Insurance Company - Insurer Innovation Award 2024
 
Histor y of HAM Radio presentation slide
Histor y of HAM Radio presentation slideHistor y of HAM Radio presentation slide
Histor y of HAM Radio presentation slide
 
Developing An App To Navigate The Roads of Brazil
Developing An App To Navigate The Roads of BrazilDeveloping An App To Navigate The Roads of Brazil
Developing An App To Navigate The Roads of Brazil
 
Kalyanpur ) Call Girls in Lucknow Finest Escorts Service 🍸 8923113531 🎰 Avail...
Kalyanpur ) Call Girls in Lucknow Finest Escorts Service 🍸 8923113531 🎰 Avail...Kalyanpur ) Call Girls in Lucknow Finest Escorts Service 🍸 8923113531 🎰 Avail...
Kalyanpur ) Call Girls in Lucknow Finest Escorts Service 🍸 8923113531 🎰 Avail...
 
Partners Life - Insurer Innovation Award 2024
Partners Life - Insurer Innovation Award 2024Partners Life - Insurer Innovation Award 2024
Partners Life - Insurer Innovation Award 2024
 
Neo4j - How KGs are shaping the future of Generative AI at AWS Summit London ...
Neo4j - How KGs are shaping the future of Generative AI at AWS Summit London ...Neo4j - How KGs are shaping the future of Generative AI at AWS Summit London ...
Neo4j - How KGs are shaping the future of Generative AI at AWS Summit London ...
 
Handwritten Text Recognition for manuscripts and early printed texts
Handwritten Text Recognition for manuscripts and early printed textsHandwritten Text Recognition for manuscripts and early printed texts
Handwritten Text Recognition for manuscripts and early printed texts
 
Injustice - Developers Among Us (SciFiDevCon 2024)
Injustice - Developers Among Us (SciFiDevCon 2024)Injustice - Developers Among Us (SciFiDevCon 2024)
Injustice - Developers Among Us (SciFiDevCon 2024)
 
Finology Group – Insurtech Innovation Award 2024
Finology Group – Insurtech Innovation Award 2024Finology Group – Insurtech Innovation Award 2024
Finology Group – Insurtech Innovation Award 2024
 
From Event to Action: Accelerate Your Decision Making with Real-Time Automation
From Event to Action: Accelerate Your Decision Making with Real-Time AutomationFrom Event to Action: Accelerate Your Decision Making with Real-Time Automation
From Event to Action: Accelerate Your Decision Making with Real-Time Automation
 
[2024]Digital Global Overview Report 2024 Meltwater.pdf
[2024]Digital Global Overview Report 2024 Meltwater.pdf[2024]Digital Global Overview Report 2024 Meltwater.pdf
[2024]Digital Global Overview Report 2024 Meltwater.pdf
 
The Role of Taxonomy and Ontology in Semantic Layers - Heather Hedden.pdf
The Role of Taxonomy and Ontology in Semantic Layers - Heather Hedden.pdfThe Role of Taxonomy and Ontology in Semantic Layers - Heather Hedden.pdf
The Role of Taxonomy and Ontology in Semantic Layers - Heather Hedden.pdf
 
CNv6 Instructor Chapter 6 Quality of Service
CNv6 Instructor Chapter 6 Quality of ServiceCNv6 Instructor Chapter 6 Quality of Service
CNv6 Instructor Chapter 6 Quality of Service
 
Driving Behavioral Change for Information Management through Data-Driven Gree...
Driving Behavioral Change for Information Management through Data-Driven Gree...Driving Behavioral Change for Information Management through Data-Driven Gree...
Driving Behavioral Change for Information Management through Data-Driven Gree...
 
Mastering MySQL Database Architecture: Deep Dive into MySQL Shell and MySQL R...
Mastering MySQL Database Architecture: Deep Dive into MySQL Shell and MySQL R...Mastering MySQL Database Architecture: Deep Dive into MySQL Shell and MySQL R...
Mastering MySQL Database Architecture: Deep Dive into MySQL Shell and MySQL R...
 
Axa Assurance Maroc - Insurer Innovation Award 2024
Axa Assurance Maroc - Insurer Innovation Award 2024Axa Assurance Maroc - Insurer Innovation Award 2024
Axa Assurance Maroc - Insurer Innovation Award 2024
 
2024: Domino Containers - The Next Step. News from the Domino Container commu...
2024: Domino Containers - The Next Step. News from the Domino Container commu...2024: Domino Containers - The Next Step. News from the Domino Container commu...
2024: Domino Containers - The Next Step. News from the Domino Container commu...
 
A Domino Admins Adventures (Engage 2024)
A Domino Admins Adventures (Engage 2024)A Domino Admins Adventures (Engage 2024)
A Domino Admins Adventures (Engage 2024)
 

Series7 Performance Whitepaper

  • 1. SERIES 7 PERFORMANCE WHITEPAPER Adaptec Series 7 SAS/SATA RAID Adapters PCIe Gen3 family of high port count 6Gb/s solutions with game-changing performance Introduction Business and consumer demand for fast and reliable access to A select group of storage adapters that claim to be designed for data and content continues to grow. Data centers are faced with PCIe Gen3 has appeared the market, but most of them max out the challenge of meeting that demand even as tight budgets at 8 ports and cannot take full advantage of PCIe Gen3’s superior force them to reduce the cost of service (COS) per user as well performance. as hardware-related Capital Expenses (CapEx) and Operating Expenses (OpEx). As we will see, only Adaptec Series 7 SAS/SATA RAID adapters, available with 16 or 24 native SAS/SATA ports, are designed to Compounding the challenge is the shrinking availability of fully exploit the high-performance characteristics of PCIe Gen3 physical space — many data centers are unwilling to take on the (Figure 1). expense of more real estate and the associated costs that come from powering and cooling larger spaces. 8 x 6Gb/s SAS ports 4.8 GB/s Bottleneck 16 x 6Gb/s SAS ports 9.6 GB/s Clearly, the days of simply adding more servers to accommo- date more traffic are over. As a result, server vendors have introduced smaller, denser, server chassis sizes that help data centers add more storage I/O capability while maintaining the same or a smaller footprint. Accordingly, storage vendors are focusing on small form-factor 8 lane PCI Gen3 8 GB/s 8 lane PCI Gen3 8 GB/s solutions that will fit into the smaller chassis while providing the high performance that data centers require. Storage components, such as hard disk drives, are getting physically Figure 1. PCIe Gen3 smaller (though increasing in capacity). Low-profile storage adapters are becoming more common as well, but only a select few are able to deliver top I/O performance and low latency in Significance of high native port count such a compact form factor. This is an important consideration In recent years, the storage industry has been transitioning from for data centers because finding the right combination of form, 3.5-inch storage drives to 2.5-inch Small Form Factor (SSF) fit and function, allows them to deploy one SKU for almost drives as advancements in technology allow storage vendors to any configuration and simplify everything from the purchase address the aforementioned physical space challenges faced by decision to installation to maintenance. data centers. Not only do SFF drives offer the obvious advantage of allowing more drives to fit into the same server rack space, but Adaptec Series 7 SAS/SATA RAID adapters address the 2.5-inch drives hold more capacity per space occupied than the needs of space-challenged modern data centers by doubling 3.5-inch drives they are replacing. Indeed, SFF HDDs now boast storage performance compared to previous-generation RAID storage capacities of 1TB or more. adapters while featuring high port counts and low-profile form factors that reduce latency, real estate requirements and power Additionally, the cost of 2.5-inch flash-based solid state drives consumption. (SSDs) is finally coming more in line with HDDs in terms of the traditional “cost per GB of capacity” metric. That, combined The new generation of PCIe with a higher read bandwidth, higher input/output operations per second (IOPs), better mechanical reliability, and higher PCI Express (PCIe) is a motherboard-mounted expansion resistance to shock and vibrations compared to HDDs, is driving bus that, through a connected device such as a RAID adapter, an industry-wide transition to SSDs. connects the host system processor to add-on peripherals, such as storage systems. Introduced into servers and workstations As the quantity of drives in a server chassis increases, the storage in 2012, the third generation of PCIe (PCIe Gen3) doubles adapter card’s port count requirements also increase. bandwidth to the host compared to its PCIe Gen2 predecessor, increasing per-lane throughput from 250 MB/s to 500 MB/s. The traditional method for increasing the storage adapter’s port count has been through the use of an expander — a board With PCIe Gen2, 8 6Gb/s SAS/SATA ports are sufficient to that enables the connection of additional attached SAS or achieve maximum performance. However, PCIe Gen3 requires SATA devices when the adapter does not have enough ports a minimum of 16 native 6Gb/s SAS/SATA ports to double the to accommodate them. However, expanders have a number bandwidth through the storage connections.
  • 2. 7,000 7,000 6,000 6,000 SERIES 7 PERFORMANCEASRWHITEPAPER 24-port 72405 RAID adapter 24-port ASR 72405 5,000 (direct connection) RAID adapter 5,000 (direct connection) 8-port Competing RAID adapter 4,000 + I/O acceleration software RAID adapter 8-port Competing 4,000 (using 1 expander) Adaptec Series 7 SAS/SATA RAID Adapters 3,000 + I/O acceleration software (using 1 expander) 2 3,000 2,000 2,000 1,000 of limitations: not only do they add complexity, they also This problem can be partially overcome if SAS devices are used, 1,000 occasionally face compatibility issues with other components 0since they are dual-ported and allow all 8 SAS port connections 0 1MB Sequential Reads 1MB Sequential Writes in the storage solution. to be leveraged through the1MB Sequential Writes (MB/sec) expander. However, as illustrated 1MB Sequential Reads (MB/sec) (MB/sec) (MB/sec) in Figures 4 and 5 below, performance of the 8 6Gb/s SAS On top of that, expanders are notorious for causing latency ports flattens out at the peak data rate and competing products and limiting data transfer bandwidth. Both of these issues have Fig 4 RAID 5 performance (24 SAS SSDs) cannot match Adaptec 5 performance (24 SAS SSDs) Fig 4 RAID Series 7 speeds. long been tolerated by data centers using HDDs, as they did not cause a huge impact on the already slow read and write 600,000 speeds of HDDs. But as higher-performance SSDs gain traction 600,000 in storage solutions, the latency and bandwidth issues of 500,000 I/Os per second 500,000 expanders have become more noticeable, and therefore less I/Os per second 400,000 24-port ASR 72405 acceptable. 400,000 RAID adapter 24-port ASR 72405 (direct connection) RAID adapter 300,000 (direct connection) In a RAID 5 configuration using 24 SATA SSDs (Figure 2), 300,000 8-port Competing RAID adapter + 8-port Competing RAID I/O acceleration the use of expanders causes a roughly 60% performance drop 200,000 software (using 1 expander) adapter + I/O acceleration software (using 1 expander) 200,000 on random read IOPs, and a roughly 20% performance drop 100,000 on OLTP read/write IOPs, compared to a direct connection 100,000 through native RAID 5 Random Performance Fig 2 ports. 0 4K Random Reads 4K Random Writes 0 8K OLTP (IOPs)Random Reads 4K Random Writes 4K (IOPs) (IOPs) 8K OLTP (IOPs) (IOPs) (IOPs) 600,000 500,000 Figure 4. RAID 5 Performance (24 SAS SSDs) 24-port ASR 72405 Fig 5 RAID 5 Sequential Performance RAID adapter Fig 5 (24 SAS Sequential Performance RAID 5 SSDs) 400,000 (direct connection) (24 SAS SSDs) Fig 2 RAID 5 Random Performance 8-port Competing RAID adapter 300,000 + I/O acceleration software (using 1 expander) 7,000 7,000 600,000 200,000 6,000 MB per second 6,000 24-port ASR 72405 500,000 MB per second 100,000 5,000 RAID adapter 24-port ASR 72405 24-port ASR 72405 5,000 RAID adapter (direct connection) RAID adapter 400,000 (direct connection) 4,000 (direct connection) 8-port Competing RAID 0 4,000 4K Random Reads 4K Random Writes 8K OLTP 8-port Competing RAID adapter adapter + 8-port Competing RAID I/O acceleration (IOPs) (IOPs) (IOPs) + I/O acceleration software 3,000 software (using 1 expander) adapter + I/O acceleration 300,000 3,000 software (using 1 expander) (using 1 expander) 2,000 200,000 2,000 Figure Fig 3 RAID 5 Sequential Performance 2. RAID 5 Random Performance (24 SATA SSDs) 1,000 100,000 1,000 0 Similarly, 0 in a RAID 5 configuration with SATA SSDs (Figure 0 1MB Sequential Reads (MB/sec) 1MB Sequential Writes 1MB Sequential Reads (MB/sec) 1MB Sequential Writes 7,000 3), theRandom Reads 4K Random Writes a roughly 70% performance drop 4K use of expanders cause (IOPs) (IOPs) 8K OLTP (IOPs) (MB/sec) (MB/sec) 6,000 sequential read MB/s, and a roughly 40% performance drop on 24-port ASR 72405 Figure 5. RAID 5 Sequential Performance (24 SAS SSDs) 5,000 sequential write MB/s, compared to a direct connection on RAID adapter (direct connection) through native ports. 4,000 Fig 3 RAID 5 Sequential Performance 8-port Competing RAID adapter + I/O acceleration software (using 1 expander) 3,000 Another drawback of expanders is the additional cost they 7,000 2,000 add to a storage solution — about $200 for the expander 6,000 1,000 24-port ASR 72405 itself plus the cost of cables plus installation, increased power 5,000 RAID adapter (direct connection) consumption, and maintenance costs. 0 1MB Sequential Reads 1MB Sequential Writes 8-port Competing RAID adapter 4,000 (MB/sec) (MB/sec) + I/O acceleration software An ideal solution for data centers would be a 6Gb/s storage (using 1 expander) 3,000 controller with a high native port count that can take advantage 2,000 of PCIe Gen3’s performance. Fig 4 RAID 5 performance (24 SAS SSDs) 1,000 However, as mentioned, most 6Gb/s storage adapters max 0 out at only 8 ports. 600,000 1MB Sequential Reads 1MB Sequential Writes (MB/sec) (MB/sec) 500,000 I/Os per second Figure 3. RAID 5 Sequential Performance (24 SATA SSDs) 400,000 Fig 4 24-port ASR 72405 RAID 5 performance (24 SAS SSDs) RAID adapter (direct connection) 300,000 8-port Competing RAID adapter + I/O acceleration 600,000 200,000 software (using 1 expander) 500,000 100,000 r second 400,000 0 24-port ASR 72405 RAID adapter 4K Random Reads 4K Random Writes 8K OLTP
  • 3. SERIES 7 PERFORMANCE WHITEPAPER Adaptec Series 7 SAS/SATA RAID Adapters 3 Adaptec Series 7 Performance comparison The Adaptec Series 7 SAS/SATA RAID adapter family features The following data compares the 24-port PCIe Gen3 Adaptec PMC’s 24 port PM8015 RAID-on-Chip (ROC), which 72405 SAS/SATA RAID adapter to a competing 8-port PCIe combines an x8 PCIe Gen3 interface with 6Gb/s SAS ports to Gen3 RAID adapter. enable a new generation of high performance, high native port count RAID adapters that are unmatched by any other ROC in Adaptec 72405 performance summary: the industry. • Max Read IOPs observed: 534k IOPs Traditionally, RAID adapter performance has centered around (RAID-0: 24x SSD: Random Read 4KB: Queue Depth = 64) read and write throughput, measured in megabytes per second • Max Write IOPs recorded: 374k IOPs (MB/s). Using this metric, Series 7 adapters perform up to (RAID-0: 24x SSD: Random Write 4KB: Queue Depth = 64) 83% better than competing RAID adapters — 6.6GB/s on sequential reads and up to 2.6GB/s on sequential writes on • Max Read throughput observed: 6400 MB/s parity RAID 5. (RAID-0: 24x SSD: Sequential Read 1MB: Queue Depth = 64) Moreover, with the popularity and growth of SSDs, input/ • Max Write throughput observed: 5229 MB/s output operations per second (IOPs) is emerging as the new (RAID-0: 24x SSD: Sequential Write 1MB: Queue Depth = 256) “lead horse” in performance metrics, with the most common • Coalesce Read IOPs performance is observed at: 1.02M IOPs configuration being the 4K random-read number. Using 4K (RAID-0: 24x SATA Sequential Read 512B: QD=256) I/O size in random scenarios is driven by the fact that most operating systems use 4K cache sizes in the server DRAM • Coalesce Write IOPs performance is observed at: 1.07M IOPs and, with that, 4K is typically the smallest I/O size for random (RAID-0: 24x SATA Sequential Write 512B: QD=256) workloads. In a RAID 5 configuration with 16 direct-connected SSDs, Series 7 adapters again lead the field with 450K IOPs — nearly 10x the performance of previous-generation RAID Platform: Intel CanoePass Qty. 1x Intel® Intel Xeon 2.9Ghz (8 Cores) (LGA2011) adapters, and more than double that of the competition. 2x 4GB (or 8GB total) DDR3-1333Mhz ECC As noted earlier, RAID adapters with only 8 native ports HBA: cannot pass PCIe Gen3’s performance gains through from Cache Mode: SSD: Logical Read=OFF / Write=OFF / Physical Write=ON the bus to the storage connections. Adaptec Series 7 RAID SAS/SATA: Logical Read=ON / Write=ON / Physical Write=ON adapters are the first on the market to take full advantage ASR 72405 Fw B20104 / Drv B20100 of PCIe Gen3 performance gains by using HD mini-SAS connectors to offer options with 16 or 24 native SAS/SATA Competing Fw v23.7.0-0035 / Drv v5.2.127.64 / MSM 12.05.03.00 adapter* * I/O acceleration software, costing additional ~ $150, ports (Figure 6). enabled via Software Key module Enclosure: Supermicro SAS216A, 24-bay SAS 6.0Gb/s Passive Backplane Supermicro SAS2-216EL2, two independent 24-bay Dual SAS Expander 6.0Gb/s Expander Backplanes 16 x 6Gb/s SAS ports Card: (Dual SMC expander backplanes needed to avoid SATA $200+ performance bottleneck) Device: Qty 24x SSD OCZ Deneva “R” Series SLC: D2RSTK251S14-005 6Gb 50GB Fw3.00E SAS Seagate Savvio 15K.3: ST9146853SS 6Gb 146GB Fw0002 8 x 6Gb/s SAS ports 16 x 6Gb/s SAS ports SATA Seagate Constellation.2: ST9500620NS 6Gb 500GB FwSN02 Software: OS Windows 2008 R2 SP1 64bit IOMETER Version: 2006.07.27 Workers: 4 Workload: SeqRead 512B/1MB, SeqWrite 512B/1MB Workload: RndRead 512B/4KB, RndWrite 512B/4KB Figure 6. Configuration Complexities and Costs Workload: OLTP 4KB/8KB Expanders vs. Direct Connect Ramp/Run: 10sec. / 30sec.
  • 4. SERIES 7 PERFORMANCE WHITEPAPER Adaptec Series 7 SAS/SATA RAID Adapters 4 The following data compares the 24-port PCIe Gen3 Adaptec 72405 SAS/SATA RAID adapter to a competing 8-port PCIe Gen3 RAID adapter. RAID – 5 SSD Based on Queue Depth = 256 24-port ASR 72405 Competing 8-port adapter Competing 8-port adapter (with (Direct connection) % I/O acceleration software) % (No I/O acceleration software) 512B Random Reads (IOPs) 531,580 163,283 225.6% 373,054 42.5% 512B Random Writes (IOPs) 28,311 16,771 68.8% 16,759 68.9% 4K Random Reads (IOPs) 529,731 163,283 224.4% 377,448 40.3% 4K Random Writes (IOPs) 28,488 16,655 71.1% 16,660 71.0% 1MB Sequential Reads (MB/s) 6,192 3,928 57.6% 3,904 58.6% 1MB Sequential Writes (MB/s) 2,237 2,185 2.4% 2,190 2.2% Note: “%” references the comparison of ASR 72405 over competing product. RAID - 10 SSD Based on Queue Depth = 256 24-port ASR 72405 Competing 8-port adapter Competing 8-port adapter (with (Direct connection) % I/O acceleration software) % (No I/O acceleration software) 512B Random Reads (IOPs) 534,824 170,338 214.0% 373,396 43.2% 512B Random Writes (IOPs) 130,851 43,901 198.1% 43,752 199.1% 4K Random Reads (IOPs) 535,546 170,092 214.9% 364,165 47.1% 4K Random Writes (IOPs) 192,051 43,808 338.4% 43,508 341.4% 1MB Sequential Reads (MB/s) 5,433 3,911 38.9% 3,888 39.7% 1MB Sequential Writes (MB/s) 2,892 1,418 104.0% 1,404 106.0% Note: “%” references the comparison of ASR 72405 over competing product. RAID – 0 SSD Based on Queue Depth = 256 24-port ASR 72405 Competing 8-port adapter Competing 8-port adapter (Direct connection) (No I/O acceleration software) % (with I/O acceleration software) % 512B Random Reads (IOPs) 531,852 169,822 213.2% 375,676 41.6% 512B Random Writes (IOPs) 238,681 166,875 43.0% 352,385 -32.3% 4K Random Reads (IOPs) 527,425 170,024 210.2% 377,964 39.5% 4K Random Writes (IOPs) 245,327 166,803 47.1% 295,252 -16.9% 1MB Sequential Reads (MB/s) 6,182 3,467 78.3% 3,435 80.0% 1MB Sequential Writes (MB/s) 5,229 2,790 87.5% 2,751 90.1% Note: “%” references the comparison of ASR 72405 over competing product.
  • 5. SERIES 7 PERFORMANCE WHITEPAPER Adaptec Series 7 SAS/SATA RAID Adapters 5 Conclusion In order to continue meeting customer demand for fast and reliable access to data and content, data centers must employ efficient storage solutions that maximize I/O capability while fitting within budgetary and physical space requirements. A new generation of PCIe Gen3 storage adapters seek to enhance storage I/O performance, but only Adaptec Series 7 SAS/SATA RAID adapters fully address the needs of space- challenged modern data centers by offering 16 ports required to maximize PCIe Gen3 performance. Series 7 adapters perform up to 83% better than competing RAID adapters in read and write throughput — 6.6 GB/s on sequential reads and up to 2.6 GB/s on sequential writes on parity RAID 5 — and lead the field with 450K IOPs — nearly 10x the performance of previous-generation RAID adapters, and more than double that of the competition. PMC-Sierra, Inc. 1380 Bordeaux Dr. World Wide Web: www.adaptec.com Sunnyvale, CA 94089 USA Pre-Sales Support: US and Canada: 1 (800) 442-7274 or (408) 957-7274 or adaptecsales@pmc-sierra.com Tel: +1 (408) 239-8000 UK: +44 1276 854 528 or uk_sales@pmc-sierra.com Australia: +61-2- 90116787 Singapore: +65-92351044 © Copyright PMC-Sierra, Inc. 2012. All rights reserved. PMC, PMC-SIERRA and Adaptec are registered trademarks of PMC-Sierra, Inc. “Adaptec by PMC” is a trademark of PMC-Sierra, Inc. Other product and company names mentioned herein may be trademarks of their respective owners. For a complete list of PMC-Sierra trademarks, see www.pmc-sierra.com/legal. WP_SERIES7PERF_100212_US Information subject to change without notice.