3. Office Building
• Average HVAC technician service call: $400
• Absenteeism
• Decreased employee performance
• Cost of over heating and over cooling
• Extreme cases of losing employees: cost of re-hiring,
re-training, loss of productivity
5. • Seating capacity: 300
• Open 360 nights / year
• Average 1 dinner / seat / night
• Total 108,000 customers / year
• Some feel air distribution-related discomfort
• 2% of customers would've stayed a bit longer if
slightly more comfortable, just enough to buy
one last drink or dessert
• Average gross profit per drink or dessert: $3
6. • Seating capacity: 300
• Open 360 nights / year
• Average 1 dinner / seat / night
• Total 108,000 customers / year
• Some feel air distribution-related discomfort
• 2% of customers would've stayed a bit longer if slightly more
comfortable, just enough to buy one last drink or dessert
• Average gross profit per drink or dessert: $3
Consequence:
$6,840 profit / year
8. A well designed HVAC System
Performs really well in theoretical
or average conditions
9. Cold air supplied at low velocity
... Will drop from standard diffusers
10. While at higher velocity...
Air jets collide and are deflected
11. How can we improve performance in
VAV applications?
Using a diffuser providing higher
tolerance to velocity and temperature
variations.
12. NEX Concave
Elements
• Won a new products contest as
the Best Heating Component
• Also ideal for cooling and VAV
applications
• Innovative architectural look
13. NEX Concave
Elements
• Swirl pattern
• Air diffused in multiple jets of
various velocities
• High induction ratio, mixes more
air, faster and more evenly
• Higher tolerance to temperature
and velocity variations
14.
15.
16. Another very common issue
causing discomfort
• Flex duct with kink or angle
• Up to 80% of airflow could be
diffused in one direction
• Same issue with rigid duct
and 90 degree elbows
17. In theory, ASHRAE recommends
• Rarely happens in real world
• Most of the time, not enough
space in the ceiling
• Sometimes installer just lazy,
poorly trained or trying to
save on time and material
18. NEX + PERFAIR
• 2 layers of air equalizing
• First layer: damper + equalizer
integrated in plenum's neck
• Second layer: the Concave
Elements. No direct exit, air is
forced to swirl inside the plenum
19. Energy Efficiency
• Stratification & uneven mixing of supplied air with
room air causing inaccurate or varying
measurements of thermostat and humidistat
• Can result in over-heating / over-cooling
• Equipment on/off and modulation = more energy
used to achieve same result as steady conditioning
20. Return on Investment
An HVAC system is a chain of components
A chain is only as strong as its weakest link
Cost adds up... Not Performance!
21. What about unpredictable factors?
• At design time, impossible to know and plan for
everything
• Added furniture and decorative objects might
obstruct and deflect air jets
• Cubicle layout modified
• Each individual's tolerance to hot and cold
22. Solutions available so far
• Blocking air in one or more directions
• Air volume control damper
• Adjustable diffusers, from horizontal to vertical
airflow
• VAV diffusers, expansive to purchase and to
install
24. PLAY Adjustable Sectors
• Only diffuser allowing for full horizontal
adjustment
• Easy to adjust, from the face and without
tools
• 1, 2, 3, 4 way and swirl with easy sectors
positioning
• Can also be adjusted by as many
degrees as required to avoid people and
objects
• Innovative architectural look
25. Example 1 - Cubicle Layout
7/8 comfort ratio
1 person complains about the cold
26. Solution 1 : adjust damper to reduce
the volume of cold air supplied
5/8 comfort ratio
32. From Above
Solved the comfort
issue...
In the most energy
efficient way
33. PLAY Adjustable Sectors
• Gives flexibility to quickly solve air distribution issues
• Fewer and cheaper service calls
• Increased general level of comfort
• Can help optimizing energy
Just PLAY with it!
37. NEX - Reliability
• High tolerance to velocity and temperature variations
• Not affected by angle of air entering diffuser
• High Induction Rate
• Great for limited space in the ceiling
• Choice of 5 Concave Element colors
38. PLAY - Flexibility
• High tolerance to velocity and temperature variations
• Not affected by angle of air entering diffuser
• High Induction Rate
• Great for limited space in the ceiling
• Choice of 5 Concave Element colors
• Optimize Comfort and Energy
• Only diffuser allowing for full
horizontal adjustment
• Easy to install, easy to use
• New design possibilities
• Save money on first service call
NEX - Reliability
39. PLAY - Flexibility
NEX - Reliability
• High tolerance to velocity and temperature variations
• Not affected by angle of air entering diffuser
Both can easily replace diffusers in existing buildings
PERFAIR plenums with Top or Side connexions
• High Induction Rate
• Great for limited space in the ceiling
• Choice of 5 Concave Element colors
• Optimize Comfort and Energy
• Only diffuser allowing for full horizontal adjustment
• Easy to install, easy to use
• New design possibilities
• Save money on first service call
Suitable for all types of ceilings (Lay-in, Drywall, Open)
40. You now have the option!
NEX and PLAY Innovative Solutions
effectiv-hvac.com