Nell’iperspazio con Rocket: il Framework Web di Rust!
InduSoft Database Redundancy Webinar
1.
2.
3. Easy-to-configure interface to Interface via standard
any SQL Relational Database: technologies: ADO.NET, ADO,
SQL Server, Oracle, MySQL, OLE-DB, and ODBC
Sybase, OSI PI, MS Access,
Excel, and others…
Redundancy and Alarm history, Event history,
Store-and-forward built-in Trend history, Process data,
features OEE dashboards, and more.
4. “HMI software is being increasingly used as a digital dashboard to show key
performance indicators (KPIs) such as overall equipment effectiveness (OEE)
for the entire enterprise, and to generate reports of actual performance versus targets.”
ARC Advisory Group
5. Local Viewer (Viewer.exe) and Thin Client Stations
(Web Thin Client, Secure Viewer Thin Client)
TCP/IP (TCP Port 1234, by default)
TCP/IP Server
InduSoft Web Studio / EmbeddedView / CEView
TCP/IP (TCP Port 3997, by default)
Studio Database Gateway
(StADOSvr.exe, StADOSvr.ini)
Must be on the
same
computer
Database Provider
(ODBC Driver, OLE-DB Provider, ADO Provider, ADO.Net Provider)
6. Thin Client Stations
TCP/IP
InduSoft Web Studio / EmbeddedView / CEView
+
Studio Database Gateway
+
Database Provider
+
SQL Relational Database
7. Thin Client Stations
TCP/IP
InduSoft Web Studio / EmbeddedView / CEView SQL Relational Database
+
Studio Database Gateway
+
Database Provider
8. Thin Client Stations
TCP/IP
InduSoft Web Studio / EmbeddedView / CEView Studio Database Gateway
+
Database Provider
+
SQL Relational Database
9. Database Connection Alarm Task
(Project > Options > Default DB)
Alarm Control
Event Task
Event Control
Trend Task
Trend Control
Grid Control
10. Redundant: In this mode, IWS saves data in InduSoft Web Studio
both Primary and Secondary Databases. If EmbeddedView
one of these databases is unavailable, IWS CEView
keeps saving data only in the database that
is available. When the database that was
unavailable becomes available again, IWS
synchronizes both databases automatically.
Store and Forward: In this mode, IWS saves
data in the Primary Database only. If the
Primary Database becomes unavailable, IWS
saves the data in the Secondary Database.
When the Primary Database becomes
available again, IWS moves the data from
the Secondary Database into the Primary Primary Secondary
Database. Database Database
11.
12. Email
(US) info@indusoft.com
(Brazil) info@indusoft.com.br
(Germany) info@indusoft-germany.de
USA
Support support@indusoft.com
Web site
(English) www.indusoft.com
(Portuguese) www.indusoft.com.br
(German) www.indusoft-germany.de Brazil
Phone (512) 349-0334 (US)
+55-11-3293-9139 (Brazil)
+49 (0) 6227-732510 (Germany) Germany
Toll-Free 877-INDUSOFT (877-463-8763)
Fax (512) 349-0375