PERME® OX2/230 Oxygen Transmission Rate Test
Yarina Gao           System
Trade5@labthink.cn
Professional, High Efficiency and Intelligent OTR System

Professional

This instrument can be used to measure oxygen transmission rate test of
film and package specimens. It has three test modes and is applicable to
various materials with high, medium and low oxygen permeability. It is
also embedded with high precision oxygen sensor, which provides a huge
test range of 0.01 ~ 65000cm3/m2•d and durable service life.
 Wide range and high precision of temperature and humidity control, adding humidity to two sides of the
      specimen, to support various combinations of non-standard test conditions
 World leading pressure compensation technology ensures accurate and repeatable test results
 Standard, proportional and continuous testing modes facilitate to minimize errors caused by human factors
      during the testing process
 Equipped with catalyst deaerator to purify carrier gas and reduce system errors
 2 types of carrier gases are available: High purity nitrogen gas or hydrogen-mixed nitrogen gas
 Convenient fast-access calibration port for temperature and humidity
 Reference film for accurate calibration


High Efficiency

This instrument can be used to measure oxygen transmission rate test of film and package specimens. It has three
test modes and is applicable to various materials with high, medium and low oxygen permeability. It is also
embedded with high precision oxygen sensor, which provides a huge test range of 0.01 ~ 65000cm3/m2•d and
durable service life.
 3 diffusion cells integrated in one instrument with lower space occupancy rate and higher test efficiency
 3 distinct or equivalent specimens can be tested individually with independent test results at one operation
 The system can be easily connected with a maximum of 10 instruments to accomplish up to 30 tests at the
     same time
 Oxygen transmission rate and water vapor transmission rate can be obtained at one operation by working
     with Labthink’s water vapor transmission rate test system together under the control of one computer


Intelligent

The instrument utilizes Labthink’s latest operating software with user-friendly operating interface and intelligent
data management. It also supports LystemTM Lab Data Sharing System, which ensures uniform management of
test results and test reports.
 Based on the user-friendly Windows operating interface for easy operation
 Save test data in different formats for convenient data transfer
 Intelligent historical data searching, comparison, analysis and printing functions
 Support Lystem™ Lab Data Sharing System for uniform management of test results and test reports


Test Principle
     Labthink Instruments Co., Ltd.144 Wuyingshan Road, Jinan, P.R.China (250031) Phone: +86 -531-85068566 FAX: +86-531-85812140
                                                                             w w w.labthinkinter n atio n al.co m.cn
The pre-conditioned specimen is mounted between the upper and lower chambers at ambient atmospheric pressure.
One chamber contains oxygen or air and the other chamber is slowly purged by a stream of nitrogen. Due to the
concentration difference between the two chambers, oxygen molecules permeate through the specimen into the
nitrogen side and are taken to the coulometric sensor where it produces corresponding amount of electrical signals.
The oxygen transmission rate is then obtained by analyzing and calculating the signals. For package samples, high
purity nitrogen flows inside the package, and oxygen or air flows outside.
This test instrument conforms to the following standards:
ISO 15105-2, GB/T 19789, ASTM D3985,ASTM F2622,ASTM F1307,ASTM F1927, JIS K7126-2,
YBB00082003


Applications

This instrument is applicable to the determination of oxygen transmission rate of:
                                           Including plastic films, plastic composite films, paper-plastic composite
                           Films           films, geomembranes, coextruded films, aluminized films, aluminum foil,
                                           aluminum composite films, and many others
                                           Including various sorts of engineering plastics, rubber, and building
    Basic                 Sheeting
                                           materials, e.g. PP, PVC and PVDC
  Applications
                                           Including plastics, rubber, paper, paper-plastic composite, glass, and metal
                                           packages, e.g. Coke bottles, peanut oil packages,           Tetra Pak materials,
                         Packages
                                           vacuum bags, metal three-piece cans, plastic packages for cosmetic, soft tube
                                           for toothpaste, jelly and yogurt cups
                      Package Caps         Test seal performance of different package caps
                           Solar
                                           Including solar back-sheets
                        Back-Sheets
                        Plastic Pipes      Including various sorts of pipes, e.g. PPR
                     Tablet Packages       Test oxygen transmission rate of the whole tablet package
                                           Plastic fuel tanks are widely used in cars for its light weight, buffering
   Extended            Fuel Tanks of       vibration and easy molding characters. But its fuel permeability is the most
  Applications              Cars           essential factor, this instrument can be used to test permeability of plastic fuel
                                           tanks
                                           Battery electrolyte is protected by the plastic shell from outside environment.
                      Battery Plastic      Battery service life is directly dependent on its water vapor permeability. This
                           Shell           instrument can be used to test water vapor transmission rate of battery plastic
                                           shell
                    Red Wine Bottles       Test oxygen transmission rate of red wine bottles


Technical Specifications


       Specifications                         Film Test                      Package Test(customization available)
                                                   3   2
                                     0.01 ~6500 cm /m ·
                                                      d(standard)
        Test Range                                                                      0.0001 ~60 cm3/pkg·
                                                                                                          d
                                   0.07 ~65000 cm3/m2· (optional)
                                                     d

  Number of Specimens                                        1~3 with independent test results

        Resolution                         0.001cm³ 2·
                                                  /m 24h                                  0.00001 cm³
                                                                                                    /pkg·
                                                                                                        d

     Labthink Instruments Co., Ltd.144 Wuyingshan Road, Jinan, P.R.China (250031) Phone: +86 -531-85068566 FAX: +86-531-85812140
                                                                             w w w.labthinkinter n atio n al.co m.cn
Temperature Range                                              15°C~55°C(standard)

 Temperature Accuracy                                               ± C (standard)
                                                                     0.1°

    Humidity Range                                        0%RH, 35%RH~90%RH,100%RH

  Humidity Accuracy                                                      ±1%RH

        Test Gas                                          Oxygen and air (not in supply scope)

  Specimen Thickness                           ≤3mm                                             ——

        Test Area                              50cm2                                            ——

                                                                       One package for temperature control device:

                                                                       specimen should be smaller than Ф150mm and
                                                                       lower than 380mm

                                                                       Three packages for temperature control device:
     Specimen Size                       108mm×108mm
                                                                       specimens should be smaller than Ф100mm,and

                                                                       lower than 380mm

                                                                       No size limitation for tests without     temperature

                                                                       control device

      Carrier Gas                             99.999% high purity nitrogen or nitrogen with 2% hydrogen

  Carrier Gas Pressure                                                  ≥0.28MPa

        Port Size                                                 1/8 inch copper tubing

    Instrument Size                                       690mm(L)×350mm(W)×360mm(H)

          Power                                               AC (85~264)V (47~63)Hz

       Net Weight                                                          70kg


Configurations

       Standard              Including Mainbody, Professional Software, Communication Cable, Vacuum Grease,
    Configuration            Round Sample Cutter, and Valve Sets
                             Including Satellite Base, Accessories for Package Test, Temperature Control Device,
    Optional Parts
                             Reference Film, Sample Cutter, and Vacuum Grease




    Labthink Instruments Co., Ltd.144 Wuyingshan Road, Jinan, P.R.China (250031) Phone: +86 -531-85068566 FAX: +86-531-85812140
                                                                            w w w.labthinkinter n atio n al.co m.cn

Contenu connexe

En vedette

ScholarOne e os Critérios SciELO (II Curso de Atualização SciELO-ScholarOne)
ScholarOne e os Critérios SciELO (II Curso de Atualização SciELO-ScholarOne)ScholarOne e os Critérios SciELO (II Curso de Atualização SciELO-ScholarOne)
ScholarOne e os Critérios SciELO (II Curso de Atualização SciELO-ScholarOne)
SciELO - Scientific Electronic Library Online
 
Panorama geral do ScholarOne na Coleção SciELO Brasil e retrospectiva 2015 (I...
Panorama geral do ScholarOne na Coleção SciELO Brasil e retrospectiva 2015 (I...Panorama geral do ScholarOne na Coleção SciELO Brasil e retrospectiva 2015 (I...
Panorama geral do ScholarOne na Coleção SciELO Brasil e retrospectiva 2015 (I...
SciELO - Scientific Electronic Library Online
 
Balangkas ng populasyon ayon sa kasarian at gulang
Balangkas ng populasyon ayon sa kasarian at gulangBalangkas ng populasyon ayon sa kasarian at gulang
Balangkas ng populasyon ayon sa kasarian at gulang
Janette Diego
 
Masters Thesis Defense Presentation
Masters Thesis Defense PresentationMasters Thesis Defense Presentation
Masters Thesis Defense Presentation
prajon
 

En vedette (12)

Unidad 2
Unidad 2Unidad 2
Unidad 2
 
Principles and essentials of partial denture design
Principles and essentials of  partial  denture designPrinciples and essentials of  partial  denture design
Principles and essentials of partial denture design
 
ScholarOne e os Critérios SciELO (II Curso de Atualização SciELO-ScholarOne)
ScholarOne e os Critérios SciELO (II Curso de Atualização SciELO-ScholarOne)ScholarOne e os Critérios SciELO (II Curso de Atualização SciELO-ScholarOne)
ScholarOne e os Critérios SciELO (II Curso de Atualização SciELO-ScholarOne)
 
Panorama geral do ScholarOne na Coleção SciELO Brasil e retrospectiva 2015 (I...
Panorama geral do ScholarOne na Coleção SciELO Brasil e retrospectiva 2015 (I...Panorama geral do ScholarOne na Coleção SciELO Brasil e retrospectiva 2015 (I...
Panorama geral do ScholarOne na Coleção SciELO Brasil e retrospectiva 2015 (I...
 
Hekasi: TOPOGRAPIYA NG PILIPINAS
Hekasi: TOPOGRAPIYA NG PILIPINASHekasi: TOPOGRAPIYA NG PILIPINAS
Hekasi: TOPOGRAPIYA NG PILIPINAS
 
Investment Strategy Case Analysis (MGT 3050)
Investment Strategy Case Analysis (MGT 3050)Investment Strategy Case Analysis (MGT 3050)
Investment Strategy Case Analysis (MGT 3050)
 
Balangkas ng populasyon ayon sa kasarian at gulang
Balangkas ng populasyon ayon sa kasarian at gulangBalangkas ng populasyon ayon sa kasarian at gulang
Balangkas ng populasyon ayon sa kasarian at gulang
 
Kabihasnang Maya
Kabihasnang MayaKabihasnang Maya
Kabihasnang Maya
 
NEUROPSYCHOLOGICAL TESTS PART - 2
NEUROPSYCHOLOGICAL TESTS PART - 2NEUROPSYCHOLOGICAL TESTS PART - 2
NEUROPSYCHOLOGICAL TESTS PART - 2
 
Aralin 4 yamang tao
Aralin 4 yamang taoAralin 4 yamang tao
Aralin 4 yamang tao
 
Masters Thesis Defense Presentation
Masters Thesis Defense PresentationMasters Thesis Defense Presentation
Masters Thesis Defense Presentation
 
5 Key Takeaways For Brand Marketers - Mobile World Congress - Day 2
5 Key Takeaways For Brand Marketers - Mobile World Congress - Day 25 Key Takeaways For Brand Marketers - Mobile World Congress - Day 2
5 Key Takeaways For Brand Marketers - Mobile World Congress - Day 2
 

Plus de Labthink Instruments Co., Ltd

Plus de Labthink Instruments Co., Ltd (20)

1 oxygen permeability test method of pudding cups
1   oxygen permeability test method of pudding cups1   oxygen permeability test method of pudding cups
1 oxygen permeability test method of pudding cups
 
1 oxygen permeability test method of pudding cups
1   oxygen permeability test method of pudding cups1   oxygen permeability test method of pudding cups
1 oxygen permeability test method of pudding cups
 
1 oxygen permeability test method of pudding cups
1   oxygen permeability test method of pudding cups1   oxygen permeability test method of pudding cups
1 oxygen permeability test method of pudding cups
 
90 Degree Adhesive Peel Strength Test on a Tensile Testing Machine
90 Degree Adhesive Peel Strength Test on a Tensile Testing Machine90 Degree Adhesive Peel Strength Test on a Tensile Testing Machine
90 Degree Adhesive Peel Strength Test on a Tensile Testing Machine
 
Plastic film hot tack test
Plastic film hot tack testPlastic film hot tack test
Plastic film hot tack test
 
Plastic film hot tack test
Plastic film hot tack testPlastic film hot tack test
Plastic film hot tack test
 
Medical blister leak and seal strength test
Medical blister leak and seal strength testMedical blister leak and seal strength test
Medical blister leak and seal strength test
 
Medical blister leak and seal strength test
Medical blister leak and seal strength testMedical blister leak and seal strength test
Medical blister leak and seal strength test
 
Break force test of ampoule bottle
Break force test of ampoule bottleBreak force test of ampoule bottle
Break force test of ampoule bottle
 
Xlw (g6) auto tensile tester
Xlw (g6) auto tensile testerXlw (g6) auto tensile tester
Xlw (g6) auto tensile tester
 
Ft f1 fogging tester
Ft f1 fogging testerFt f1 fogging tester
Ft f1 fogging tester
 
Box Compression Tester
Box Compression TesterBox Compression Tester
Box Compression Tester
 
Xyd 15 k
Xyd 15 kXyd 15 k
Xyd 15 k
 
Tensile strength at break tester
Tensile strength at break testerTensile strength at break tester
Tensile strength at break tester
 
Tension and Elongation rate tester
Tension and Elongation rate testerTension and Elongation rate tester
Tension and Elongation rate tester
 
Material universal testing machine
Material universal testing machine Material universal testing machine
Material universal testing machine
 
Puncture strength tester for packaging
Puncture strength tester for packaging Puncture strength tester for packaging
Puncture strength tester for packaging
 
Tensile Tester
Tensile TesterTensile Tester
Tensile Tester
 
Tensile strength testing machine for flexible materials
Tensile strength testing machine for flexible materials Tensile strength testing machine for flexible materials
Tensile strength testing machine for flexible materials
 
Water Vapor Transmission Rate Tester
Water Vapor Transmission Rate TesterWater Vapor Transmission Rate Tester
Water Vapor Transmission Rate Tester
 

Oxygen Transmission Rate Tester

  • 1. PERME® OX2/230 Oxygen Transmission Rate Test Yarina Gao System Trade5@labthink.cn Professional, High Efficiency and Intelligent OTR System Professional This instrument can be used to measure oxygen transmission rate test of film and package specimens. It has three test modes and is applicable to various materials with high, medium and low oxygen permeability. It is also embedded with high precision oxygen sensor, which provides a huge test range of 0.01 ~ 65000cm3/m2•d and durable service life.  Wide range and high precision of temperature and humidity control, adding humidity to two sides of the specimen, to support various combinations of non-standard test conditions  World leading pressure compensation technology ensures accurate and repeatable test results  Standard, proportional and continuous testing modes facilitate to minimize errors caused by human factors during the testing process  Equipped with catalyst deaerator to purify carrier gas and reduce system errors  2 types of carrier gases are available: High purity nitrogen gas or hydrogen-mixed nitrogen gas  Convenient fast-access calibration port for temperature and humidity  Reference film for accurate calibration High Efficiency This instrument can be used to measure oxygen transmission rate test of film and package specimens. It has three test modes and is applicable to various materials with high, medium and low oxygen permeability. It is also embedded with high precision oxygen sensor, which provides a huge test range of 0.01 ~ 65000cm3/m2•d and durable service life.  3 diffusion cells integrated in one instrument with lower space occupancy rate and higher test efficiency  3 distinct or equivalent specimens can be tested individually with independent test results at one operation  The system can be easily connected with a maximum of 10 instruments to accomplish up to 30 tests at the same time  Oxygen transmission rate and water vapor transmission rate can be obtained at one operation by working with Labthink’s water vapor transmission rate test system together under the control of one computer Intelligent The instrument utilizes Labthink’s latest operating software with user-friendly operating interface and intelligent data management. It also supports LystemTM Lab Data Sharing System, which ensures uniform management of test results and test reports.  Based on the user-friendly Windows operating interface for easy operation  Save test data in different formats for convenient data transfer  Intelligent historical data searching, comparison, analysis and printing functions  Support Lystem™ Lab Data Sharing System for uniform management of test results and test reports Test Principle Labthink Instruments Co., Ltd.144 Wuyingshan Road, Jinan, P.R.China (250031) Phone: +86 -531-85068566 FAX: +86-531-85812140 w w w.labthinkinter n atio n al.co m.cn
  • 2. The pre-conditioned specimen is mounted between the upper and lower chambers at ambient atmospheric pressure. One chamber contains oxygen or air and the other chamber is slowly purged by a stream of nitrogen. Due to the concentration difference between the two chambers, oxygen molecules permeate through the specimen into the nitrogen side and are taken to the coulometric sensor where it produces corresponding amount of electrical signals. The oxygen transmission rate is then obtained by analyzing and calculating the signals. For package samples, high purity nitrogen flows inside the package, and oxygen or air flows outside. This test instrument conforms to the following standards: ISO 15105-2, GB/T 19789, ASTM D3985,ASTM F2622,ASTM F1307,ASTM F1927, JIS K7126-2, YBB00082003 Applications This instrument is applicable to the determination of oxygen transmission rate of: Including plastic films, plastic composite films, paper-plastic composite Films films, geomembranes, coextruded films, aluminized films, aluminum foil, aluminum composite films, and many others Including various sorts of engineering plastics, rubber, and building Basic Sheeting materials, e.g. PP, PVC and PVDC Applications Including plastics, rubber, paper, paper-plastic composite, glass, and metal packages, e.g. Coke bottles, peanut oil packages, Tetra Pak materials, Packages vacuum bags, metal three-piece cans, plastic packages for cosmetic, soft tube for toothpaste, jelly and yogurt cups Package Caps Test seal performance of different package caps Solar Including solar back-sheets Back-Sheets Plastic Pipes Including various sorts of pipes, e.g. PPR Tablet Packages Test oxygen transmission rate of the whole tablet package Plastic fuel tanks are widely used in cars for its light weight, buffering Extended Fuel Tanks of vibration and easy molding characters. But its fuel permeability is the most Applications Cars essential factor, this instrument can be used to test permeability of plastic fuel tanks Battery electrolyte is protected by the plastic shell from outside environment. Battery Plastic Battery service life is directly dependent on its water vapor permeability. This Shell instrument can be used to test water vapor transmission rate of battery plastic shell Red Wine Bottles Test oxygen transmission rate of red wine bottles Technical Specifications Specifications Film Test Package Test(customization available) 3 2 0.01 ~6500 cm /m · d(standard) Test Range 0.0001 ~60 cm3/pkg· d 0.07 ~65000 cm3/m2· (optional) d Number of Specimens 1~3 with independent test results Resolution 0.001cm³ 2· /m 24h 0.00001 cm³ /pkg· d Labthink Instruments Co., Ltd.144 Wuyingshan Road, Jinan, P.R.China (250031) Phone: +86 -531-85068566 FAX: +86-531-85812140 w w w.labthinkinter n atio n al.co m.cn
  • 3. Temperature Range 15°C~55°C(standard) Temperature Accuracy ± C (standard) 0.1° Humidity Range 0%RH, 35%RH~90%RH,100%RH Humidity Accuracy ±1%RH Test Gas Oxygen and air (not in supply scope) Specimen Thickness ≤3mm —— Test Area 50cm2 —— One package for temperature control device: specimen should be smaller than Ф150mm and lower than 380mm Three packages for temperature control device: Specimen Size 108mm×108mm specimens should be smaller than Ф100mm,and lower than 380mm No size limitation for tests without temperature control device Carrier Gas 99.999% high purity nitrogen or nitrogen with 2% hydrogen Carrier Gas Pressure ≥0.28MPa Port Size 1/8 inch copper tubing Instrument Size 690mm(L)×350mm(W)×360mm(H) Power AC (85~264)V (47~63)Hz Net Weight 70kg Configurations Standard Including Mainbody, Professional Software, Communication Cable, Vacuum Grease, Configuration Round Sample Cutter, and Valve Sets Including Satellite Base, Accessories for Package Test, Temperature Control Device, Optional Parts Reference Film, Sample Cutter, and Vacuum Grease Labthink Instruments Co., Ltd.144 Wuyingshan Road, Jinan, P.R.China (250031) Phone: +86 -531-85068566 FAX: +86-531-85812140 w w w.labthinkinter n atio n al.co m.cn