SlideShare une entreprise Scribd logo
1  sur  8
Télécharger pour lire hors ligne
Warmline XPS
Extruded Poly Bonded to Plasterboard
The Warmline insulating laminates are designed as a simple
effective way to improve the thermal efficiency in both walls
and roof applications. They are fully applicable with Part L
of the building regulations.
Insulation and
Drywall Products
Fixing instructions for Dot and dab
For bonding Warmline range to a wall use a proprietary
gypsum based adhesive.
Please follow the manufacturers instructions. As per
manufacturers recommendations apply a continuous
ribbon of adhesive around any openings.
Apply 3 vertical rows of adhesive dabs to the walls at
300mm centres. Also insure that there is a continuous
bead at the bottom and top.
After the adhesive has set fix a minimum of 2 insulation
anchors through the board into the wall. They must go
into the masonry by a minimum of 30mm.
Fixing instructions for mechanical fixing
Fix to the wall treated batons 50mm x 25mm at a
maximum of 600mm centres. Also fit horizontal batons at
both floor and ceiling level.
Then fit the Warmline board using drywall screws at
150mm centres. Always insure that they penetrate the
batons by 25mm.
When installing boards to rafters fix them at right angles
to the timbers. To ensure a solid finish bridging pieces are
to used in-between the rafters.
Insulation Manufacturers & Distributors
For more details you can contact our technical team
Unit 6, Coopers Point, Coopers Lane, Knowsley Industrial Park, Liverpool L33 7UB
Sales: 07872 989689 Main Depot: 01515 463260 Fax: 0151 5484543
Product Description Overall Foam Plasterboard Sheets m2
per Thermal U-value U-value
Code & Size Thickness Thickness Thickness per Pallet Board Resistance Fixed Batons Dot & Dab
R-value (W/m2
K) (W/m2
K)
27mm 17.5mm 9.5mm 78 2.88 0.560 0.838 0.884
30mm 17.5mm 12.5mm 70 2.88 0.575 0.827 0.873
35mm 25.5mm 9.5mm 60 2.88 0.795 0.700 0.732
38mm 25.5mm 12.5mm 55 2.88 0.810 0.693 0.724
40mm 30.5mm 9.5mm 53 2.88 0.942 0.635 0.661
43mm 30.5mm 12.5mm 50 2.88 0.957 0.629 0.654
45mm 35.5mm 9.5mm 47 2.88 1.089 0.580 0.602
48mm 35.5mm 12.5mm 44 2.88 1.104 0.575 0.597
55mm 45.5mm 9.5mm 38 2.88 1.383 0.496 0.512
Warmline
XPS
1.2 x 2.4
Extruded
Poly
Bonded to
Plasterboard
Calculations are based on a 215mm thick solid brickwork wall and includes a 2mm plaster skim coat. Timber battens are 25x50mm at 600mm Centres
Extruded Poly Bonded to Plasterboard Benefits
G All thicknesses readily available
G Simple solution to upgrading walls and roofs
G Quick and easy to install
G Can be used for both newbuild and refurb
G A simple way to meet building regulations
G Cost effective return
Technical Specifications
WWarmline EPS
Polystyrene Bonded to Plasterboard
The Warmline insulating laminates are designed as a simple
effective way to improve the thermal efficiency in both walls
and roof applications. They are fully applicable with Part L
of the building regulations.
Insulation and
Drywall Products
Fixing instructions for Dot and dab
For bonding Warmline range to a wall use a proprietary
gypsum based adhesive.
Please follow the manufacturers instructions. As per
manufacturers recommendations apply a continuous
ribbon of adhesive around any openings.
Apply 3 vertical rows of adhesive dabs to the walls at
300mm centres. Also insure that there is a continuous
bead at the bottom and top.
After the adhesive has set fix a minimum of 2 insulation
anchors through the board into the wall. They must go
into the masonry by a minimum of 30mm.
Fixing instructions for mechanical fixing
Fix to the wall treated batons 50mm x 25mm at a
maximum of 600mm centres. Also fit horizontal batons at
both floor and ceiling level.
Then fit the Warmline board using drywall screws at
150mm centres. Always insure that they penetrate the
batons by 25mm.
When installing boards to rafters fix them at right angles
to the timbers. To ensure a solid finish bridging pieces are
to used in-between the rafters.
Insulation Manufacturers & Distributors
For more details you can contact our technical team
Unit 6, Coopers Point, Coopers Lane, Knowsley Industrial Park, Liverpool L33 7UB
Sales: 07872 989689 Main Depot: 01515 463260 Fax: 0151 5484543
Calculations are based on a 215mm thick solid brickwork wall and includes a 2mm plaster skim coat. Timber battens are 25x50mm at 600mm Centres
Expanded Poly Bonded to Plasterboard Benefits
G All thicknesses readily available
G Simple solution to upgrading walls and roofs
G Quick and easy to install
G Can be used for both newbuild and refurb
G A simple way to meet building regulations
G Cost effective return
Technical Specifications
Product Description Overall Foam Plasterboard Sheets m2
per Thermal U-value U-value
Code & Size Thickness Thickness Thickness per Pallet Board Resistance Fixed Batons Dot & Dab
R-value (W/m2
K) (W/m2
K)
22mm 12.5mm 9.5mm 95 2.88 0.374 0.992 1.059
30mm 20.5mm 9.5mm 70 2.88 0.584 0.821 0.866
40mm 30.5mm 9.5mm 53 2.88 0.720 0.739 0.775
50mm 40.5mm 9.5mm 42 2.88 1.111 0.573 0.594
60mm 50.5mm 9.5mm 35 2.88 1.374 0.498 0.514
Warmline
EPS
1.2 x 2.4
Expanded
Poly
Bonded to
Plasterboard
Warmline PIR
PIR Bonded to Plasterboard
The Warmline insulating laminates are designed as a simple
effective way to improve the thermal efficiency in both walls
and roof applications. They are fully applicable with Part L
of the building regulations.
Insulation and
Drywall Products
Fixing instructions for Dot and dab
For bonding Warmline range to a wall use a proprietary
gypsum based adhesive.
Please follow the manufacturers instructions. As per
manufacturers recommendations apply a continuous
ribbon of adhesive around any openings.
Apply 3 vertical rows of adhesive dabs to the walls at
300mm centres. Also insure that there is a continuous
bead at the bottom and top.
After the adhesive has set fix a minimum of 2 insulation
anchors through the board into the wall. They must go
into the masonry by a minimum of 30mm.
Fixing instructions for mechanical fixing
Fix to the wall treated batons 50mm x 25mm at a
maximum of 600mm centres. Also fit horizontal batons at
both floor and ceiling level.
Then fit the warmline board using drywall screws at
150mm centres. Always insure that they penetrate the
batons by 25mm.
When installing boards to rafters fix them at right angles
to the timbers. To ensure a solid finish bridging pieces are
to used in-between the rafters.
Insulation Manufacturers & Distributors
For more details you can contact our technical team
Unit 6, Coopers Point, Coopers Lane, Knowsley Industrial Park, Liverpool L33 7UB
Sales: 07872 989689 Main Depot: 01515 463260 Fax: 0151 5484543
Calculations are based on a 215mm thick solid brickwork wall and includes a 2mm plaster skim coat. Timber battens are 25x50mm at 600mm Centres
Polyisocyanurate Foam Bonded to Plasterboard
Benefits
G All thicknesses readily available
G Simple solution to upgrading walls and roofs
G Quick and easy to install
G Can be used for both newbuild and refurb
G A simple way to meet building regulations
G Cost effective return
Technical Specifications
Product Description Overall Foam Plasterboard Sheets m2
per Thermal U-value U-value
Code & Size Thickness Thickness Thickness per Pallet Board Resistance Fixed Batons Dot & Dab
R-value (W/m2
K) (W/m2
K)
27mm 17mm 9.5mm 78 2.88 0.840 0.679 0.709
29mm 17mm 12.5mm 74 2.88 0.855 0.672 0.701
35mm 25mm 9.5mm 60 2.88 1.181 0.551 0.571
38mm 25mm 12.5mm 55 2.88 1.196 0.547 0.566
48mm 38mm 9.5mm 44 2.88 1.772 0.416 0.427
50mm 38mm 12.5mm 42 2.88 1.787 0.413 0.424
60mm 50mm 9.5mm 35 2.88 2.318 0.339 0.346
62.5mm 50mm 12.5mm 34 2.88 2.333 0.337 0.344
70mm 60mm 9.5mm 30 2.88 2.772 0.294 0.299
72.5mm 60mm 12.5mm 29 2.88 2.787 0.292 0.298
80mm 70mm 9.5mm 26 2.88 3.227 0.259 0.263
82.5mm 70mm 12.5mm 25 2.88 3.242 0.258 0.262
90mm 80mm 9.5mm 23 2.88 3.681 0.232 0.235
92.5mm 80mm 12.5mm 22 2.88 3.696 0.231 0.234
102mm 90mm 12.5mm 21 2.88 4.152 0.209 0.212
Warmline
PIR
1.2 x 2.4
PIR
Bonded to
Plasterboard
Warmline PHE
Phenolic Bonded to Plasterboard
The Warmline insulating laminates are designed as a simple
effective way to improve the thermal efficiency in both walls
and roof applications. They are fully applicable with Part L
of the building regulations.
Insulation and
Drywall Products
Fixing instructions for Dot and dab
For bonding Warmline range to a wall use a proprietary
gypsum based adhesive.
Please follow the manufacturers instructions. As per
manufacturers recommendations apply a continuous
ribbon of adhesive around any openings.
Apply 3 vertical rows of adhesive dabs to the walls at
300mm centres. Also insure that there is a continuous
bead at the bottom and top.
After the adhesive has set fix a minimum of 2 insulation
anchors through the board into the wall. They must go
into the masonry by a minimum of 30mm.
Fixing instructions for mechanical fixing
Fix to the wall treated batons 50mm x 25mm at a
maximum of 600mm centres. Also fit horizontal batons at
both floor and ceiling level.
Then fit the Warmline board using drywall screws at
150mm centres. Always insure that they penetrate the
batons by 25mm.
When installing boards to rafters fix them at right angles
to the timbers. To ensure a solid finish bridging pieces are
to used in-between the rafters.
Insulation Manufacturers & Distributors
For more details you can contact our technical team
Unit 6, Coopers Point, Coopers Lane, Knowsley Industrial Park, Liverpool L33 7UB
Sales: 07872 989689 Main Depot: 01515 463260 Fax: 0151 5484543
Calculations are based on a 215mm thick solid brickwork wall and includes a 2mm plaster skim coat. Timber battens are 25x50mm at 600mm Centres
Phenolic Foam Bonded to Plasterboard Benefits
G All thicknesses readily available
G Simple solution to upgrading walls and roofs
G Quick and easy to install
G Can be used for both newbuild and refurb
G A simple way to meet building regulations
G Cost effective return
Technical Specifications
Product Description Overall Foam Plasterboard Sheets m2
per Thermal U-value U-value
Code & Size Thickness Thickness Thickness per Pallet Board Resistance Fixed Batons Dot & Dab
R-value (W/m2
K) (W/m2
K)
30mm 20mm 9.5mm 74 2.88 0.997 0.613 0.638
35mm 25mm 9.5mm 66 2.88 1.235 0.535 0.554
37.5mm 25mm 12.5mm 58 2.88 1.250 0.531 0.549
40mm 30mm 9.5mm 55 2.88 1.474 0.474 0.489
42.5mm 30mm 12.5mm 52 2.88 1.489 0.471 0.485
50mm 40mm 9.5mm 44 2.88 1.950 0.387 0.397
52.5mm 40mm 12.5mm 42 2.88 1.965 0.385 0.394
60mm 50mm 9.5mm 36 2.88 2.426 0.327 0.334
62.5mm 50mm 12.5mm 35 2.88 2.441 0.325 0.332
70mm 60mm 9.5mm 32 2.88 2.902 0.283 0.288
72.5mm 70mm 12.5mm 30 2.88 3.393 0.248 0.252
80mm 70mm 9.5mm 28 2.88 3.378 0.249 0.253
90mm 80mm 9.5mm 24 2.88 3.855 0.223 0.224
Warmline
PHE
1.2 x 2.4
Phenolic
Bonded to
Plasterboard
Insulation facing can either be foil or paper, please specify when ordering.

Contenu connexe

Tendances

Tendances (17)

Z-Board (EIFS) 60mm and 100mm
Z-Board (EIFS) 60mm and 100mmZ-Board (EIFS) 60mm and 100mm
Z-Board (EIFS) 60mm and 100mm
 
3M Fire Barrier Intumescent Sealant - 3M CP25WB+
3M Fire Barrier Intumescent Sealant - 3M CP25WB+3M Fire Barrier Intumescent Sealant - 3M CP25WB+
3M Fire Barrier Intumescent Sealant - 3M CP25WB+
 
Pisa brochure
Pisa brochurePisa brochure
Pisa brochure
 
3M Fire Barrier Intumescent Moldable Putty
3M Fire Barrier Intumescent Moldable Putty3M Fire Barrier Intumescent Moldable Putty
3M Fire Barrier Intumescent Moldable Putty
 
Car park bq
Car park bqCar park bq
Car park bq
 
British Gypsum Innovation Seminar - Newman Street
British Gypsum Innovation Seminar - Newman StreetBritish Gypsum Innovation Seminar - Newman Street
British Gypsum Innovation Seminar - Newman Street
 
Bolderstone brochure
Bolderstone brochureBolderstone brochure
Bolderstone brochure
 
Ripl profile
Ripl profileRipl profile
Ripl profile
 
Ultra Universal Pipe Wrap & Universal Pipe Sleeve Brochure
Ultra Universal Pipe Wrap & Universal Pipe Sleeve BrochureUltra Universal Pipe Wrap & Universal Pipe Sleeve Brochure
Ultra Universal Pipe Wrap & Universal Pipe Sleeve Brochure
 
Boq sample
Boq sampleBoq sample
Boq sample
 
Stone cladding
Stone claddingStone cladding
Stone cladding
 
Bill Of Quantities
Bill Of QuantitiesBill Of Quantities
Bill Of Quantities
 
Brochure prospectus folder v2
Brochure prospectus folder v2Brochure prospectus folder v2
Brochure prospectus folder v2
 
Porta Cabin Presentation
Porta Cabin PresentationPorta Cabin Presentation
Porta Cabin Presentation
 
12777 coastal single pages part108
12777  coastal single pages part10812777  coastal single pages part108
12777 coastal single pages part108
 
Inflateaspace Brochure
Inflateaspace BrochureInflateaspace Brochure
Inflateaspace Brochure
 
How to build a retaining wall
How to build a retaining wallHow to build a retaining wall
How to build a retaining wall
 

En vedette

Want to Earn Extra Income
Want to Earn Extra IncomeWant to Earn Extra Income
Want to Earn Extra IncomeJagtar Dhindsa
 
Remove Ads by Jabuticaba Easily
Remove Ads by Jabuticaba EasilyRemove Ads by Jabuticaba Easily
Remove Ads by Jabuticaba Easilyjacobprime
 
Konsep ideologi dan pancasila
Konsep ideologi dan pancasilaKonsep ideologi dan pancasila
Konsep ideologi dan pancasilaSMA Unggul Del
 
Foreverlivingproducts Enjoy Healthy Life
Foreverlivingproducts Enjoy Healthy LifeForeverlivingproducts Enjoy Healthy Life
Foreverlivingproducts Enjoy Healthy LifeJagtar Dhindsa
 
Rtm baltic pr_2015
Rtm baltic pr_2015Rtm baltic pr_2015
Rtm baltic pr_2015Eremenko Ann
 
Hays digital people 2015 the last one and only!
Hays digital people 2015 the last one and only!Hays digital people 2015 the last one and only!
Hays digital people 2015 the last one and only!Eremenko Ann
 
Earn A lot more without disturbing Your Present Profession jagtar singh 98888...
Earn A lot more without disturbing Your Present Profession jagtar singh 98888...Earn A lot more without disturbing Your Present Profession jagtar singh 98888...
Earn A lot more without disturbing Your Present Profession jagtar singh 98888...Jagtar Dhindsa
 
Bonduelle - Rapport Financier 2008/2009
Bonduelle - Rapport Financier 2008/2009Bonduelle - Rapport Financier 2008/2009
Bonduelle - Rapport Financier 2008/2009Bonduelle
 
Bonduelle - Rapport d'activité et de développement durable 2010 - 2011
Bonduelle - Rapport d'activité et de développement durable 2010 - 2011Bonduelle - Rapport d'activité et de développement durable 2010 - 2011
Bonduelle - Rapport d'activité et de développement durable 2010 - 2011Bonduelle
 

En vedette (14)

Want to Earn Extra Income
Want to Earn Extra IncomeWant to Earn Extra Income
Want to Earn Extra Income
 
Shravan 3+
Shravan 3+Shravan 3+
Shravan 3+
 
Remove Ads by Jabuticaba Easily
Remove Ads by Jabuticaba EasilyRemove Ads by Jabuticaba Easily
Remove Ads by Jabuticaba Easily
 
NOF Ebrochure - 2015 (1)
NOF Ebrochure - 2015 (1)NOF Ebrochure - 2015 (1)
NOF Ebrochure - 2015 (1)
 
Konsep ideologi dan pancasila
Konsep ideologi dan pancasilaKonsep ideologi dan pancasila
Konsep ideologi dan pancasila
 
Paludisme
PaludismePaludisme
Paludisme
 
Foreverlivingproducts Enjoy Healthy Life
Foreverlivingproducts Enjoy Healthy LifeForeverlivingproducts Enjoy Healthy Life
Foreverlivingproducts Enjoy Healthy Life
 
DIABETES MELLITUS
DIABETES MELLITUSDIABETES MELLITUS
DIABETES MELLITUS
 
Rtm baltic pr_2015
Rtm baltic pr_2015Rtm baltic pr_2015
Rtm baltic pr_2015
 
Hays digital people 2015 the last one and only!
Hays digital people 2015 the last one and only!Hays digital people 2015 the last one and only!
Hays digital people 2015 the last one and only!
 
Earn A lot more without disturbing Your Present Profession jagtar singh 98888...
Earn A lot more without disturbing Your Present Profession jagtar singh 98888...Earn A lot more without disturbing Your Present Profession jagtar singh 98888...
Earn A lot more without disturbing Your Present Profession jagtar singh 98888...
 
Efficient recruitment
Efficient recruitmentEfficient recruitment
Efficient recruitment
 
Bonduelle - Rapport Financier 2008/2009
Bonduelle - Rapport Financier 2008/2009Bonduelle - Rapport Financier 2008/2009
Bonduelle - Rapport Financier 2008/2009
 
Bonduelle - Rapport d'activité et de développement durable 2010 - 2011
Bonduelle - Rapport d'activité et de développement durable 2010 - 2011Bonduelle - Rapport d'activité et de développement durable 2010 - 2011
Bonduelle - Rapport d'activité et de développement durable 2010 - 2011
 

Similaire à Warmline range Data Sheets

Tukang pasang plafon gypsum 081381278719.pdf
Tukang pasang plafon gypsum 081381278719.pdfTukang pasang plafon gypsum 081381278719.pdf
Tukang pasang plafon gypsum 081381278719.pdftukang_gypsum
 
Gyptone edge d1 installation manual
Gyptone edge d1 installation manualGyptone edge d1 installation manual
Gyptone edge d1 installation manualDan Palmer
 
011 - Proposed Ground Floor plan
011 - Proposed Ground Floor plan011 - Proposed Ground Floor plan
011 - Proposed Ground Floor planDanny Chiverton
 
Freelance project management case studies - residential
Freelance project management case studies - residentialFreelance project management case studies - residential
Freelance project management case studies - residentialgrahamelanders
 
Freelance project management residential
Freelance project management residentialFreelance project management residential
Freelance project management residentialgrahamelanders
 
Freelance project management residential
Freelance project management residentialFreelance project management residential
Freelance project management residentialgrahamelanders
 
Polyform's new products in provisional patent
Polyform's new products in provisional patentPolyform's new products in provisional patent
Polyform's new products in provisional patentpolyformbinder
 
9.0 Installation of Wall Batts.pdf
9.0 Installation of Wall Batts.pdf9.0 Installation of Wall Batts.pdf
9.0 Installation of Wall Batts.pdfInsulation2
 
20130901_jumbogrid_WEB
20130901_jumbogrid_WEB20130901_jumbogrid_WEB
20130901_jumbogrid_WEBJanine Course
 
Flinders park apc_pisabrochure
Flinders park apc_pisabrochureFlinders park apc_pisabrochure
Flinders park apc_pisabrochurekristenjames
 
RIW Cementjoint Datasheet
RIW Cementjoint DatasheetRIW Cementjoint Datasheet
RIW Cementjoint DatasheetRIW Ltd
 
Magnum Firechest installation instructions
Magnum Firechest installation instructionsMagnum Firechest installation instructions
Magnum Firechest installation instructionsSchiedel UK
 
Zego 60mm fire form
Zego 60mm fire formZego 60mm fire form
Zego 60mm fire formsimonjohn2
 
Laminate Decorative Panels and Exterior Wall Cladding By UFC International
Laminate Decorative Panels and Exterior Wall Cladding By UFC InternationalLaminate Decorative Panels and Exterior Wall Cladding By UFC International
Laminate Decorative Panels and Exterior Wall Cladding By UFC InternationalIndiaMART InterMESH Limited
 
Guidelines for construction of masonry with siporex
Guidelines for construction of masonry with siporexGuidelines for construction of masonry with siporex
Guidelines for construction of masonry with siporexPriya Raj
 
Timber Panels Installation
Timber Panels InstallationTimber Panels Installation
Timber Panels InstallationDeziner Panels
 
Reznoclad Brochure final_2016
Reznoclad Brochure final_2016Reznoclad Brochure final_2016
Reznoclad Brochure final_2016Reznoclad HPL
 
Isokern Celsius stove system installation instructions
Isokern Celsius stove system installation instructionsIsokern Celsius stove system installation instructions
Isokern Celsius stove system installation instructionsSchiedel UK
 

Similaire à Warmline range Data Sheets (20)

Tukang pasang plafon gypsum 081381278719.pdf
Tukang pasang plafon gypsum 081381278719.pdfTukang pasang plafon gypsum 081381278719.pdf
Tukang pasang plafon gypsum 081381278719.pdf
 
Gyptone edge d1 installation manual
Gyptone edge d1 installation manualGyptone edge d1 installation manual
Gyptone edge d1 installation manual
 
011 - Proposed Ground Floor plan
011 - Proposed Ground Floor plan011 - Proposed Ground Floor plan
011 - Proposed Ground Floor plan
 
Gypsum Board
Gypsum BoardGypsum Board
Gypsum Board
 
Freelance project management case studies - residential
Freelance project management case studies - residentialFreelance project management case studies - residential
Freelance project management case studies - residential
 
Freelance project management residential
Freelance project management residentialFreelance project management residential
Freelance project management residential
 
Freelance project management residential
Freelance project management residentialFreelance project management residential
Freelance project management residential
 
Polyform's new products in provisional patent
Polyform's new products in provisional patentPolyform's new products in provisional patent
Polyform's new products in provisional patent
 
9.0 Installation of Wall Batts.pdf
9.0 Installation of Wall Batts.pdf9.0 Installation of Wall Batts.pdf
9.0 Installation of Wall Batts.pdf
 
Build a carport
Build a carportBuild a carport
Build a carport
 
20130901_jumbogrid_WEB
20130901_jumbogrid_WEB20130901_jumbogrid_WEB
20130901_jumbogrid_WEB
 
Flinders park apc_pisabrochure
Flinders park apc_pisabrochureFlinders park apc_pisabrochure
Flinders park apc_pisabrochure
 
RIW Cementjoint Datasheet
RIW Cementjoint DatasheetRIW Cementjoint Datasheet
RIW Cementjoint Datasheet
 
Magnum Firechest installation instructions
Magnum Firechest installation instructionsMagnum Firechest installation instructions
Magnum Firechest installation instructions
 
Zego 60mm fire form
Zego 60mm fire formZego 60mm fire form
Zego 60mm fire form
 
Laminate Decorative Panels and Exterior Wall Cladding By UFC International
Laminate Decorative Panels and Exterior Wall Cladding By UFC InternationalLaminate Decorative Panels and Exterior Wall Cladding By UFC International
Laminate Decorative Panels and Exterior Wall Cladding By UFC International
 
Guidelines for construction of masonry with siporex
Guidelines for construction of masonry with siporexGuidelines for construction of masonry with siporex
Guidelines for construction of masonry with siporex
 
Timber Panels Installation
Timber Panels InstallationTimber Panels Installation
Timber Panels Installation
 
Reznoclad Brochure final_2016
Reznoclad Brochure final_2016Reznoclad Brochure final_2016
Reznoclad Brochure final_2016
 
Isokern Celsius stove system installation instructions
Isokern Celsius stove system installation instructionsIsokern Celsius stove system installation instructions
Isokern Celsius stove system installation instructions
 

Warmline range Data Sheets

  • 1. Warmline XPS Extruded Poly Bonded to Plasterboard The Warmline insulating laminates are designed as a simple effective way to improve the thermal efficiency in both walls and roof applications. They are fully applicable with Part L of the building regulations. Insulation and Drywall Products
  • 2. Fixing instructions for Dot and dab For bonding Warmline range to a wall use a proprietary gypsum based adhesive. Please follow the manufacturers instructions. As per manufacturers recommendations apply a continuous ribbon of adhesive around any openings. Apply 3 vertical rows of adhesive dabs to the walls at 300mm centres. Also insure that there is a continuous bead at the bottom and top. After the adhesive has set fix a minimum of 2 insulation anchors through the board into the wall. They must go into the masonry by a minimum of 30mm. Fixing instructions for mechanical fixing Fix to the wall treated batons 50mm x 25mm at a maximum of 600mm centres. Also fit horizontal batons at both floor and ceiling level. Then fit the Warmline board using drywall screws at 150mm centres. Always insure that they penetrate the batons by 25mm. When installing boards to rafters fix them at right angles to the timbers. To ensure a solid finish bridging pieces are to used in-between the rafters. Insulation Manufacturers & Distributors For more details you can contact our technical team Unit 6, Coopers Point, Coopers Lane, Knowsley Industrial Park, Liverpool L33 7UB Sales: 07872 989689 Main Depot: 01515 463260 Fax: 0151 5484543 Product Description Overall Foam Plasterboard Sheets m2 per Thermal U-value U-value Code & Size Thickness Thickness Thickness per Pallet Board Resistance Fixed Batons Dot & Dab R-value (W/m2 K) (W/m2 K) 27mm 17.5mm 9.5mm 78 2.88 0.560 0.838 0.884 30mm 17.5mm 12.5mm 70 2.88 0.575 0.827 0.873 35mm 25.5mm 9.5mm 60 2.88 0.795 0.700 0.732 38mm 25.5mm 12.5mm 55 2.88 0.810 0.693 0.724 40mm 30.5mm 9.5mm 53 2.88 0.942 0.635 0.661 43mm 30.5mm 12.5mm 50 2.88 0.957 0.629 0.654 45mm 35.5mm 9.5mm 47 2.88 1.089 0.580 0.602 48mm 35.5mm 12.5mm 44 2.88 1.104 0.575 0.597 55mm 45.5mm 9.5mm 38 2.88 1.383 0.496 0.512 Warmline XPS 1.2 x 2.4 Extruded Poly Bonded to Plasterboard Calculations are based on a 215mm thick solid brickwork wall and includes a 2mm plaster skim coat. Timber battens are 25x50mm at 600mm Centres Extruded Poly Bonded to Plasterboard Benefits G All thicknesses readily available G Simple solution to upgrading walls and roofs G Quick and easy to install G Can be used for both newbuild and refurb G A simple way to meet building regulations G Cost effective return Technical Specifications
  • 3. WWarmline EPS Polystyrene Bonded to Plasterboard The Warmline insulating laminates are designed as a simple effective way to improve the thermal efficiency in both walls and roof applications. They are fully applicable with Part L of the building regulations. Insulation and Drywall Products
  • 4. Fixing instructions for Dot and dab For bonding Warmline range to a wall use a proprietary gypsum based adhesive. Please follow the manufacturers instructions. As per manufacturers recommendations apply a continuous ribbon of adhesive around any openings. Apply 3 vertical rows of adhesive dabs to the walls at 300mm centres. Also insure that there is a continuous bead at the bottom and top. After the adhesive has set fix a minimum of 2 insulation anchors through the board into the wall. They must go into the masonry by a minimum of 30mm. Fixing instructions for mechanical fixing Fix to the wall treated batons 50mm x 25mm at a maximum of 600mm centres. Also fit horizontal batons at both floor and ceiling level. Then fit the Warmline board using drywall screws at 150mm centres. Always insure that they penetrate the batons by 25mm. When installing boards to rafters fix them at right angles to the timbers. To ensure a solid finish bridging pieces are to used in-between the rafters. Insulation Manufacturers & Distributors For more details you can contact our technical team Unit 6, Coopers Point, Coopers Lane, Knowsley Industrial Park, Liverpool L33 7UB Sales: 07872 989689 Main Depot: 01515 463260 Fax: 0151 5484543 Calculations are based on a 215mm thick solid brickwork wall and includes a 2mm plaster skim coat. Timber battens are 25x50mm at 600mm Centres Expanded Poly Bonded to Plasterboard Benefits G All thicknesses readily available G Simple solution to upgrading walls and roofs G Quick and easy to install G Can be used for both newbuild and refurb G A simple way to meet building regulations G Cost effective return Technical Specifications Product Description Overall Foam Plasterboard Sheets m2 per Thermal U-value U-value Code & Size Thickness Thickness Thickness per Pallet Board Resistance Fixed Batons Dot & Dab R-value (W/m2 K) (W/m2 K) 22mm 12.5mm 9.5mm 95 2.88 0.374 0.992 1.059 30mm 20.5mm 9.5mm 70 2.88 0.584 0.821 0.866 40mm 30.5mm 9.5mm 53 2.88 0.720 0.739 0.775 50mm 40.5mm 9.5mm 42 2.88 1.111 0.573 0.594 60mm 50.5mm 9.5mm 35 2.88 1.374 0.498 0.514 Warmline EPS 1.2 x 2.4 Expanded Poly Bonded to Plasterboard
  • 5. Warmline PIR PIR Bonded to Plasterboard The Warmline insulating laminates are designed as a simple effective way to improve the thermal efficiency in both walls and roof applications. They are fully applicable with Part L of the building regulations. Insulation and Drywall Products
  • 6. Fixing instructions for Dot and dab For bonding Warmline range to a wall use a proprietary gypsum based adhesive. Please follow the manufacturers instructions. As per manufacturers recommendations apply a continuous ribbon of adhesive around any openings. Apply 3 vertical rows of adhesive dabs to the walls at 300mm centres. Also insure that there is a continuous bead at the bottom and top. After the adhesive has set fix a minimum of 2 insulation anchors through the board into the wall. They must go into the masonry by a minimum of 30mm. Fixing instructions for mechanical fixing Fix to the wall treated batons 50mm x 25mm at a maximum of 600mm centres. Also fit horizontal batons at both floor and ceiling level. Then fit the warmline board using drywall screws at 150mm centres. Always insure that they penetrate the batons by 25mm. When installing boards to rafters fix them at right angles to the timbers. To ensure a solid finish bridging pieces are to used in-between the rafters. Insulation Manufacturers & Distributors For more details you can contact our technical team Unit 6, Coopers Point, Coopers Lane, Knowsley Industrial Park, Liverpool L33 7UB Sales: 07872 989689 Main Depot: 01515 463260 Fax: 0151 5484543 Calculations are based on a 215mm thick solid brickwork wall and includes a 2mm plaster skim coat. Timber battens are 25x50mm at 600mm Centres Polyisocyanurate Foam Bonded to Plasterboard Benefits G All thicknesses readily available G Simple solution to upgrading walls and roofs G Quick and easy to install G Can be used for both newbuild and refurb G A simple way to meet building regulations G Cost effective return Technical Specifications Product Description Overall Foam Plasterboard Sheets m2 per Thermal U-value U-value Code & Size Thickness Thickness Thickness per Pallet Board Resistance Fixed Batons Dot & Dab R-value (W/m2 K) (W/m2 K) 27mm 17mm 9.5mm 78 2.88 0.840 0.679 0.709 29mm 17mm 12.5mm 74 2.88 0.855 0.672 0.701 35mm 25mm 9.5mm 60 2.88 1.181 0.551 0.571 38mm 25mm 12.5mm 55 2.88 1.196 0.547 0.566 48mm 38mm 9.5mm 44 2.88 1.772 0.416 0.427 50mm 38mm 12.5mm 42 2.88 1.787 0.413 0.424 60mm 50mm 9.5mm 35 2.88 2.318 0.339 0.346 62.5mm 50mm 12.5mm 34 2.88 2.333 0.337 0.344 70mm 60mm 9.5mm 30 2.88 2.772 0.294 0.299 72.5mm 60mm 12.5mm 29 2.88 2.787 0.292 0.298 80mm 70mm 9.5mm 26 2.88 3.227 0.259 0.263 82.5mm 70mm 12.5mm 25 2.88 3.242 0.258 0.262 90mm 80mm 9.5mm 23 2.88 3.681 0.232 0.235 92.5mm 80mm 12.5mm 22 2.88 3.696 0.231 0.234 102mm 90mm 12.5mm 21 2.88 4.152 0.209 0.212 Warmline PIR 1.2 x 2.4 PIR Bonded to Plasterboard
  • 7. Warmline PHE Phenolic Bonded to Plasterboard The Warmline insulating laminates are designed as a simple effective way to improve the thermal efficiency in both walls and roof applications. They are fully applicable with Part L of the building regulations. Insulation and Drywall Products
  • 8. Fixing instructions for Dot and dab For bonding Warmline range to a wall use a proprietary gypsum based adhesive. Please follow the manufacturers instructions. As per manufacturers recommendations apply a continuous ribbon of adhesive around any openings. Apply 3 vertical rows of adhesive dabs to the walls at 300mm centres. Also insure that there is a continuous bead at the bottom and top. After the adhesive has set fix a minimum of 2 insulation anchors through the board into the wall. They must go into the masonry by a minimum of 30mm. Fixing instructions for mechanical fixing Fix to the wall treated batons 50mm x 25mm at a maximum of 600mm centres. Also fit horizontal batons at both floor and ceiling level. Then fit the Warmline board using drywall screws at 150mm centres. Always insure that they penetrate the batons by 25mm. When installing boards to rafters fix them at right angles to the timbers. To ensure a solid finish bridging pieces are to used in-between the rafters. Insulation Manufacturers & Distributors For more details you can contact our technical team Unit 6, Coopers Point, Coopers Lane, Knowsley Industrial Park, Liverpool L33 7UB Sales: 07872 989689 Main Depot: 01515 463260 Fax: 0151 5484543 Calculations are based on a 215mm thick solid brickwork wall and includes a 2mm plaster skim coat. Timber battens are 25x50mm at 600mm Centres Phenolic Foam Bonded to Plasterboard Benefits G All thicknesses readily available G Simple solution to upgrading walls and roofs G Quick and easy to install G Can be used for both newbuild and refurb G A simple way to meet building regulations G Cost effective return Technical Specifications Product Description Overall Foam Plasterboard Sheets m2 per Thermal U-value U-value Code & Size Thickness Thickness Thickness per Pallet Board Resistance Fixed Batons Dot & Dab R-value (W/m2 K) (W/m2 K) 30mm 20mm 9.5mm 74 2.88 0.997 0.613 0.638 35mm 25mm 9.5mm 66 2.88 1.235 0.535 0.554 37.5mm 25mm 12.5mm 58 2.88 1.250 0.531 0.549 40mm 30mm 9.5mm 55 2.88 1.474 0.474 0.489 42.5mm 30mm 12.5mm 52 2.88 1.489 0.471 0.485 50mm 40mm 9.5mm 44 2.88 1.950 0.387 0.397 52.5mm 40mm 12.5mm 42 2.88 1.965 0.385 0.394 60mm 50mm 9.5mm 36 2.88 2.426 0.327 0.334 62.5mm 50mm 12.5mm 35 2.88 2.441 0.325 0.332 70mm 60mm 9.5mm 32 2.88 2.902 0.283 0.288 72.5mm 70mm 12.5mm 30 2.88 3.393 0.248 0.252 80mm 70mm 9.5mm 28 2.88 3.378 0.249 0.253 90mm 80mm 9.5mm 24 2.88 3.855 0.223 0.224 Warmline PHE 1.2 x 2.4 Phenolic Bonded to Plasterboard Insulation facing can either be foil or paper, please specify when ordering.