The Panduit no battery, maintenance-free UPS lowers the risk of downtime, provides lower TCO and features easy integration and remote device management.
2. Uninterruptible Power Supply (UPS)
2
• No battery design eliminates the #1 cause of
UPS failures
• Maintenance-free lowers the risk of downtime
associated with lack of maintenance and
lowers cost of ownership
• Improved integration into control panels or
equipment cabinets
Remote management of multiple devices
User interface through standard web browser
FactoryTalk® network interface with EtherNet/IP™
Compact, single device saves space
–40 to +60 deg C (-40 to +140°F) operating
temperature range
FactoryTalk® is registered by Rockwell Automation in the Patent and Trademark Office of the United States.
EtherNet/IP trademark of ODVA.
3. 3
Why do you need a UPS?
• US manufacturing firms experience an
average 3.9 power interruption events per
year
• Most power interruptions are very short
duration (blips)
• Power “blips” result in long restart times, of
3 to 5 minutes, for microprocessor-based
devices such as managed switches and
Human Machine Interfaces (HMIs)
• These power interruptions cost US
manufacturing firms an average of $2107
per event, or $8,217 per year
• A UPS can pay for itself in 1 to 3 months
by preventing equipment restarts caused
by short power interruptions
Source: The Cost of Power Disturbances to Industrial & Digital Economy Companies
EPRI’s Consortium for Electric Infrastructure for a Digital Society (CEIDS)
Percent of establishments by number of outages in a typical year (Avg. # 3.9)
Average cost per outage by duration
4. “Batteries are a pain in the UPS”
4
• Battery failures are the #1 cause of
UPS failures
• Battery UPS units require frequent
maintenance such as
inspection, testing and replacement
• Frequent maintenance drives up
operating and overhead costs
• Batteries typically require Hazardous
Waste disposal methods
• Batteries can “outgas” Hydrogen
which can build up to dangerous
levels inside an enclosure
Source: Addressing the Leading Root Causes of Downtime, Emerson Network Power
Top root causes of downtime cited by data center professionals. Totals
exceed 100 percent because data center professionals cited multiple root-
causes over a period of two years.
5. A No Battery, Maintenance-Free UPS solution
5
• Modern ultracapacitors instead of
rechargeable batteries
• Maintenance-free, up to 20 year
life, with half the cost of ownership
compared to ordinary battery UPS
• No capacity loss at low temperatures
and less impact on life at high
temperatures (compared to batteries)
• Patent pending “stack balancing”
provides the most energy storage in
the least amount of space
• Patent pending “predictive
monitoring” monitors temperature to
measure capacity over time
6. Better UPS device management
6
• Ethernet communications provides
remote monitoring instead of serial
or USB cable and a laptop
• Standard web browser can be used
to manage all devices from the
office, plant floor or mobile device
• Plug-and-play interoperability with
Rockwell Automation FactoryTalk®
network devices
No “visiting” every device
No opening cabinets
No PPE gear required
No software to download
No software to configure
No host device limitations
FactoryTalk® View faceplates
EtherNet/IP CONFORMANCE
TESTED™
FactoryTalk® is registered by Rockwell Automation in the Patent and Trademark Office of the United States.
EtherNet/IP CONFORMANCE TESTED™ is a certification mark of ODVA.
7. Improved UPS Integration
7
• Single, compact 80mm wide unit saves DIN rail space
– Typical battery UPS is 2 pieces, 120-240mm wide combined
• Wide operating temperature range of -40 to +60° C (-40 to +140°F)
• No need to oversize the battery for low temperature operation
• No premium for long life, high temperature operation
• No chance of Hydrogen “outgassing” from battery charge
– No need to vent enclosure to avoid gas buildup
• Supports dual, redundant power supply configurations (with optional
accessory Load Sense Module)
8. Target Applications
8
Backup for devices with long restart times
after a power interruption
• Industrial Managed Switches
– Allen-Bradley® Stratix™ series
– Cisco IE3000 (IE3K) series
– Provides backup power for 2 base
switches or base switch plus expansion
modules
• Human Machine Interfaces
– Allen-Bradley® PanelView Plus™ models
400 and 600
• Other low power 24VDC devices
– Up to 35W Output Load capacity
Allen-Bradley® is registered by Rockwell Automation in the Patent and Trademark Office of the United States.
Stratix™ is a trademark of Rockwell Automation.
PanelView Plus™ is a trademark of Rockwell Automation.
14. Remote Management with
FactoryTalk® View Faceplate
14
• Panduit UPS is the only DC UPS with an
Ethernet interface
– Alternatives are expensive rack mount, AC
units intended for Data Center environments
– Allows remote monitoring Zone Network
“health” – Power Supplies and Temperature
• EtherNet/IP CONFORMANCE TESTED™ for
easy plug-and-play integration with Rockwell
Automation FactoryTalk® network devices
– EtherNet/IP™ and FactoryTalk® Network
support files downloadable
UPS Faceplate on A-B HMI
FactoryTalk® is registered by Rockwell Automation in the Patent and Trademark Office of the United States.
EtherNet/IP CONFORMANCE TESTED™ is a certification mark of ODVA.
EtherNET/IP trademark of ODVA.
16. Dual, redundant power supply configuration
16
Optional Load Sense Module (LSM) for IA UPS
• Senses load not powered by UPS
• Eliminates extra heat in pass-through mode
• Allows UPS to monitor Primary and Secondary power supplies, and load device
System Block Diagram