Beginners Guide to TikTok for Search - Rachel Pearson - We are Tilt __ Bright...
Benchmark Quick Guide
1. A
TuRning
pOinT
in
buiLDing
DESign
BEnChMarK SUpporT
TEChnICal SErvICES Kingspan Benchmark
Tel: +44 (0) 800 970 9036 (uK) greenfield business park 2
Tel: +353 (0) 42 969 8529 (ireland) greenfield
Email: technical@kingspanbenchmark.com Holywell
Flintshire
CH8 7gJ
MarKETInG SErvICES uK
(SaMplES anD lITEraTUrE)
Tel: +44 (0) 1352 716100
Tel: +44 (0) 1352 717251 (uK)
Fax: +44 (0) 1352 710161
Tel: +353 (0) 42 969 8540 (ireland)
info@kingspanbenchmark.com
Email: info@kingspanbenchmark.com
www.kingspanbenchmark.com
QUoTaTIon hoTlInE
Tel: +44 (0) 1352 716400 (uK)
Tel: +353 (0) 42 969 8555 (ireland)
Email: bestprice@kingspanbenchmark.com
SalES
Tel; +44 (0) 1352 716100 (uK)
Tel: +353 (0) 42 969 8500 (ireland)
Email: info@kingspanbenchmark.com
ROOF, WALL
& FAÇADE
SYSTEMS
QUICK GUIDE
This brochure is printed on paper made from 80% recycled post-consumer fibre
and 20% virgin pulp sourced from responsibly managed and sustainable forests
2. InTroDUCInG BEnChMarK ConTEnTS
A turning point in building design
introducing a turning point in roof, wall and façade and specifications. inspirational façades in exciting WallS & FaCaDES 5
systems. Welcome to benchmark, your reference colours, textures and finishes. Roof systems that
buiLD OpTiOnS 6-7
point for a complete insulated building envelope. raise the standard in performance. All backed
benchmark brings together all the elements to help with the Total benchmark guarantee and thorough METALLiCS 8-9
you create wall solutions to fit your building designs testing procedures.
gLASS 10 - 11
pOWERpAnEL pV 12 - 13
CERAMiC 14 - 17
CEMEnTiTiOuS bOARDS 18 - 19
WOOD 20 - 23
OpTiMO 24 - 25
CuRVEWALL 26 - 27
LOuVRE 28 - 29
REnDER 30 - 31
rooFS 33
pOWERpAnEL pV 34 - 35
gREEn ROOF’S 36 - 37
STAnDing SEAM 38 - 41
AnCiLLARiES 42
COLOuRS 43 - 56
bEnCHMARK SERViCES 58
bEnCHMARK benchmark offers free techincal
TEChnICal advice to all of it’s customers.
This service is available 5 days a week.
+44 (0) 800 970 9036 (uK) For our opening hours please see:
+353 (0) 42 969 8529 (ireland) www.kingspanbenchmark.com/contact-us
technical@kingspanbenchmark.com
3
3. WallS & FaÇaDES
Transform the face
of architecture
With a wide choice in colour and texture, there are no
limits to what you can create with benchmark façades.
From modern metallic, to traditional brick and warm
wood finishes. We’ve combined style and performance
to offer you the complete façade solution without
having to compromise.
The quick guide is designed to make it fast and easy to
select and create your complete wall solution. Simply
find a build option that best fits your project and then
choose your preferred façade from our wide selection.
5
4. BUIlD opTIonS
1. BEnChMarK KarrIEr panEl SYSTEM 2. InSUlaTED panEl SYSTEM
InTroDUCTIon InTroDUCTIon
The benchmark Karrier panel is a unique The benchmark insulated panel System includes
insulated panel that has been specifically a variety of premium insulated panels with
designed and tested to support benchmark’s different profiles, textures and colours.
ranges of façades. The benchmark insulated panel can be laid vertically and
it can be laid vertically and horizontally, with or without a tophat horizontally, for design flexibility. The system provides excellent
section to suite the benchmark façade. The benchmark façade weather resistance, thermal, acoustic, fire and structural
pages to follow will specify the recommended build options from performance. A lightweight solution, it can be rapidly installed on
Kingspan benchmark. buildings of any height and integrates easily with doors, windows,
glazing, louvers and traditional construction materials. The
The system provides excellent weather resistance, thermal, benchmark insulated panels are metal faced panels that make the
acoustic, fire and structural performance. The benchmark Karrier building watertight, removing the façade off the critical path and
panel is a metal faced insulated panel that makes the building enabling internal fit out to start sooner.
watertight, removing the façade off the critical path and enabling
internal fit out to start sooner.
SYSTEM ovErvIEW SYSTEM ovErvIEW
• A Benchmark façade is fixed to a Benchmark Karrier Panel • The Benchmark insulated panel is fixed to a braced
by a specified railing system BEnEFITS Kingspan Multibeam purlin and rail system, available from BEnEFITS
• The Benchmark Karrier Panel is fixed to a braced Kingspan Kingspan Structural products at www.kingspanstructural.com.
• A wide range of through fix and secret fix Benchmark façades • Available in a wide range of profiles, textures and colours
Multibeam purlin and rail system, available from Kingspan Alternatively, it can also be fixed to a lightweight steel framing
are available • Can be laid vertically or horizontally
Structural products at www.kingspanstructural.com. Alternatively, system, available from Kingspan profiles & Sections at
• Multiple size façade finishes, very low limitations • A long spanning insulated panel is also available
the benchmark Karrier panel can be fixed to a lightweight steel www.kingspanprofiles.com
• Suitable for buildings at any height • Suitable for buildings at any height
framing system, available from Kingspan profiles & Sections at • If an internal plasterboard lining is required, a proprietary stud-
• Simple and fast to construct • Simple and fast to construct
www.kingspanprofiles.com wall system may be installed internally
• Easily accommodates openings, penetrations and complex • Easily accommodates openings, penetrations and
• If an internal plasterboard lining is required, a proprietary • This system integrates with Build Option 1 for design flexibility
façades complex façades
stud-wall system may be installed internally and to provide interesting elevations.
• Simple integration with doors, windows, glazing, louvres and • Simple integration with doors, windows, glazing, louvres and
A comprehensive set of robust and thermally efficient details are traditional construction materials A comprehensive set of robust and thermally efficient details are traditional construction materials
available from the website, to allow easy design and detailing. • Lifetime insulation continuity, thermal performance and available from the website, to allow easy design and detailing. • Lifetime insulation continuity, thermal performance and
Our benchmark Technical Services Department are on hand to airtightness (less than 5m3/hr/m²) certainty. Our benchmark Technical Services Department are on hand to airtightness (less than 5m3/hr/m²) certainty.
help where other details are required. Contact one of our team • Independently tested system, including CWCT external building help where other details are required. Contact one of our team • Independently tested system, including CWCT external
on the details at the bottom of the page. envelope on the details at the bottom of the page. building envelope
• Available with the Total Benchmark Guarantee • Available with the Total Benchmark Guarantee
U-valUES • Manufactured and supplied under a quality system certified to U-valUES • Manufactured and supplied under a quality system certified to
bS En iSO 9001: 2000 bS En iSO 9001: 2000
panel Thickness (mm) 70 80 100 120 140 The u-values are product specific, please refer to the product
• Manufacturing plants are ISO 14001 (Environmentally) • Manufacturing plants are ISO 14001 (Environmentally)
u-value (W/m2K) 0.29 0.26 0.21 0.18 0.16
pages for their thermal performance and weight values.
accredited accredited
Weight kg/m2 ^ 11.9 12.3 13.1 13.9 14.6
All of the above u-values are calculated in compliance with building Regulations
bEnCHMARK
Approved Documents L2A & L2b (England & Wales), Technical Handbooks Domestic For more information www.kingspanbenchmark.com/products/build-options
and non-Domestic Sections 6 (Scotland), part F2 (northern ireland) and part L
(Republic of ireland - based on the Overall Heat Loss Method). +44 (0) 800 970 9036 (UK) +353 (0) 42 969 8529 (Ireland)
The u-values reflected above take the whole build into consideration. For the purpose
of these calculations, the Kingspan Multibeam purlin and rail system was used in conjunction
TEChnICal
with a standard 12.5mm gypsum wall board, with a lambda value of 0.19 W/mK).
^ Weight of the benchmark Karrier panel only. 7
5. STEEl, aCM, al & Zn
METallICS STEEl, aCM, al & Zn
InTroDUCTIon TEChnICal ovErvIEW
Steel, Aluminium Composite Material (ACM), Colours
Aluminium and Zinc metallics provide striking Aluminium is available in an anodized finish, pre-painted Steel is available in a stainless steel option (shown on page 44),
aluminium sheets, post painted aluminium sheets & post powder pre-coated & weathered option, including Corten A Alloy
finishes that give buildings a modern stylised coated. Colourful façades that can be produced in virtually any (see project image on opposite page). A selection of ACM
appearance. Metallic façades are truly bespoke. colour bS, nCS and RAL or matched to other colours on request colour options can be seen on page 45 and Zinc on page 46.
They can be tailored to your project and offer an endless range of subject to minimum production quantities. The complete range can be seen on the benchmark website.
colours. Combined with superior aesthetics the benchmark Karrier
panels provide excellent weather protection to the building envelope.
The table below shows what type of metal the cassette option is available in and what build option it is suitable for.
They are simple to integrate into other systems with matching
flashings and ancillaries available to create a complete finish. Metal Type Cassette option
hook-on- Interlocking recessed Fix
Shingle Tray
BEnEFITS Cassette plank Cassette
• Superior aesthetics Aluminium
• Provides excellent weather protection to the building envelope
0.9mm ppC only 3
• A wide range of material and cassette options, including
through fix and secret fix options 1.5mm 3
• Virtually maintenance free 2.0mm 3 3 3 3
• Individual cassettes can be removed and replaced as necessary
3.0mm 3 3 3
• Comprehensive design and technical support
• Flashings and ancillaries are available in the same material for a ACM
complete solution 4.0mm 3 3 3
• Long strip metal options are available in Zinc and Steel
6.0mm 3 3
• Independently tested system, including CWCT external building
envelope for the Tray cassette option Zinc
• Available with the Total Benchmark Guarantee 1.0mm 3 3
• Manufactured and supplied under a quality system certified to
Steel
bS En iSO 9001: 2000
• Manufacturing plants are ISO 14001 (Environmentally) Weathered Steel (Coreten A)
accredited 1.5mm 3 3 3
3.0mm 3 3
Cassette options
Stainless Steel
0.8mm 3 3
1.0mm 3 3
2.0mm 3 3 3
3.0mm 3 3
buiLD OpTiOn 1 1 1 1 1
1. Hook-On-Cassette 2. interlocking plank 3. Shingle 4. Recessed Fix Cassette 5. Tray
bEnCHMARK For more information
on this product
www.kingspanbenchmark.com/products/wall/metallic
+44 (0) 800 970 9036 (UK) +353 (0) 42 969 8529 (Ireland)
TEChnICal
METALLiCS STEEl, aCM, al & Zn | 9
6. ColoUrED & rEFlECTIvE
GlaSS ColoUrED & rEFlECTIvE
TEChnICal ovErvIEW
Material Description Dimensions
Coloured glass consists of two layers of 4mm toughened clear Standard module 1206mm length by 606mm height (inclusive of
pilkington glass and combinations of poly vinyl butyral (pVb) 8mm joint) and maximum module 1000mm length by 1000mm
interlayers to obtain the desired colour. height (coloured glass only).
Reflective glass also consists of two layers of glass; the front layer Face panel thickness of the coloured glass ranges from 8.38mm
is a 6mm Stopsol hard coat reflective glass and the rear is a 3mm to 9.5mm depending on colour and reflective glass ranges from
pilkington clear. 9.76mm-10.14mm.
product Tolerance Façade & rail Weight
Laminate slippage tolerance is in accordance with bS En iSO Module size and thickness are dependant on project design
12543-5: 1998 (glass in building. Laminated glass and laminated requirements. For accurate weights for your specific application,
safety glass. Dimensions and edge finishing). glass cutting contact the benchmark Technical Services Department.
tolerance is +/- 1mm.
aluminium Secondary rail System
The extruded aluminium secondary rail system conforms to
bS En 12020-1: 2008 (Aluminium and aluminium alloys).
Extruded precision profiles in alloys En AW-6060 and
En AW-6063. Technical conditions for inspection and delivery) -
powder-coated black.
attachment
Extruded aluminium straps, conforming to bS En 1220-1: 2008 in
6063/T6 grade alloy, are structurally bonded to the glass façade.
InTroDUCTIon
Straps are secured to the aluminium secondary rail system using
benchmark coloured and reflective façades interlays are made with heat and light stable pigments instead self-drilling/self-tapping stainless steel fasteners.
of dyes in order to resist fading. Advanced glazing performance
give architects and designers more freedom creates a glass façade that is strong, stable and reduces solar
Colours
with glass than ever before with thousands of The coloured façades are available in a range of colours
energy transmittance and heat build up.
shown on page 47 and the reflective façade is available in
colour options available. a mirrored effect.
Build options
BEnEFITS please refer to build option 1, shown on page 6.
• Thousands of colour possibilities • Flashings and ancillaries are available in similar colours
• Provides excellent weather protection to the building envelope for a complete solution
• Safely protects against accidental glass impact, breakage or • Independently tested system, including CWCT external
fall out building envelope
• Secret fix option available, with a through fix option • Available with the Total Benchmark Guarantee
being developed. • Manufactured and supplied under a quality system certified
• Virtually maintenance free to bS En iSO 9001: 2000
• Individual modules can be removed and replaced as necessary • Manufacturing plants are ISO 14001 (Environmentally)
• Comprehensive design and technical support accredited
bEnCHMARK For more information
on this product
www.kingspanbenchmark.com/products/wall/glass
+44 (0) 800 970 9036 (UK) +353 (0) 42 969 8529 (Ireland)
TEChnICal
gLASS ColoUrED anD rEFlECTIvE | 11
7. Wall GlaZE
(pv) Wall GlaZE
InTroDUCTIon TEChnICal ovErvIEW
powerpanel Wall glaze uses solar Material Description Dimensions
photovoltaics to generate clean energy Wall glaze comprises one layer of 4mm glass with a 2mm tedlar Maximum module 1206mm length by 606mm height (inclusive
backsheet, incorporating encapsulated solar cells. of 8mm joint) and maximum actual panel size 1198mm length
for buildings, even if the sky is overcast.
product Tolerance x 598mm height.
Once installed every kW produced by pV Face panel thickness: 5.5mm maximum.
Wall glaze cutting tolerance is +/- 1mm.
has zero carbon emissions, helping to reduce Façade & rail Weight
aluminium Secondary rail System
environmental impact as well as energy costs. nominally 16.6kg/m²
The extruded aluminium secondary rail system conforms to
Wall glaze is suitable for most wall applications on new build bS En 12020-1: 2008 (Aluminium and aluminium alloys).
or refurbishment projects and has 21 enhanced efficiency Extruded precision profiles in alloys En AW-6060 and
polycrystalline silicon cells in series, with 75 to 80 watts of En AW-6063. Technical conditions for inspection and delivery) -
nominal maximum power. powder-coated black.
attachment
Extruded aluminium straps, conforming to bS En 1220-1: 2008 in
6063/T6 grade alloy, are structurally bonded to the glass façade.
Straps are secured to the aluminium secondary rail system using
self-drilling/self-tapping stainless steel fasteners.
Colours
black & white background colour option.
Feed-In Tariffs
Refer to the web address below for information.
Build options
please refer to build option 1, shown on page 6.
BEnEFITS
• Integrated bypass diodes to minimise shading effects • Once installed every kW produced has zero carbon emissions,
• Structurally-bonded aluminium fixing straps for easy installation which significantly reduces the carbon footprint
onto façade structures • Not dependent on fossil or nuclear fuels
• Available in 75 Wp or 80 Wp • No harmful CO2 emissions
• Light aluminium frame for ease of installation, available in • Provides excellent weather protection to the building envelope
white or black • Secret fix option only, no visible fixing
• Single-source integrated wall, façade and solar PV provider • Individual modules can be removed and replaced as necessary
• Installed by MCS approved contractors • Comprehensive design and technical support
• Optimised, value-engineered systems for rapid installation • Flashings and ancillaries are available in similar colours
• Project analysis / viability, design, supply, installation, testing, for a complete solution
commissioning and handover service • Independently tested system, including CWCT external
• Virtually maintenance free building envelope
• Generates clean, inflation proof electricity – reduces • Available with the Total Benchmark Guarantee
energy costs • Manufactured and supplied under a quality system certified
• Can increase the saleable / rentable value of the building to bS En iSO 9001: 2000
• Manufacturing plants are ISO 14001 (Environmentally) accredited
bEnCHMARK For more information
on this product
www.kingspanbenchmark.com/products/wall/photovoltaic
+44 (0) 800 970 9036 (UK) +353 (0) 42 969 8529 (Ireland)
TEChnICal
pOWERpAnEL pV Wall GlaZE | 13
8. CEraMIC GranITE
CEraMIC CEraMIC GranITE
TEChnICal ovErvIEW
Material Description Dimensions
The ceramic granite is typically refined clays, quartz, feldspars and Maximum module 1206mm length x 606mm height (inclusive
metal oxides vitrified under high temperature and pressure, with of 8mm joint) and maximum actual panel size 1198mm length
mesh reinforcement to rear face. x 598mm height. Smaller bespoke sizes are available.
product Tolerance Face panel thickness: 12mm maximum.
Thickness, sides straightness, rectangularity and surface flatness are Façade & rail Weight
all in accordance with bS En 14411: 2003 (Ceramic tiles Annex g Module size is dependant on project design requirements.
(Dry-pressed ceramic tiles with low water absorption group bla)). For accurate weights for your specific application, contact the
aluminium Secondary rail System benchmark Technical Services Department.
The extruded aluminium secondary rail system conforms to
bS En 12020-1: 2008 (Aluminium and aluminium alloys.
Extruded precision profiles in alloys En AW-6060 and
En AW-6063.Technical conditions for inspection and delivery) -
powder coated black.
attachment
The extruded aluminium straps, conforming to bS En 12020-1:
2008 in 6063/T6 grade alloy, are secured to the ceramic granite
façade panel using undercut stainless steel expanding anchors.
Straps are secured to the aluminium secondary rail system using
self-drilling / self-tapping stainless steel fasteners. The secondary rail
system is securely fastened to the benchmark Karrier panel with
InTroDUCTIon expanding self-fixing aluminium and stainless steel fasteners.
Ceramic granite provides an attractive Finished in natural unpolished, satin pre-polished, mirror polished Fire
or metallic. Exceptionally hardwearing and cost effective, The ceramic granite façades have Class 1 fire rating to bS 476-7:
solution available in a wide choice of colours in protecting both your building and budget. 1997 (Surface spread of flame of products), and are Class 0 as
veined or grained variations that replicate the defined by building Regulations.
appearance of granite and marble. Colours
please refer to page 48 to see the metallic, polished and textured
BEnEFITS range.
• A patented manufacturing process achieves individual veining • Provides excellent weather protection to the building envelope Build options
on the tiles replicating that of quarried stone • Secret fix option only, no visible fixing please refer to build option 1, shown on page 6
• Benchmark will cut Ceramic Granite to your project • Individual modules can be removed and replaced as necessary
dimensions, openings and features • Comprehensive design and technical support
• Ceramic Granite is highly resistant to moisture and frost • Flashings and ancillaries are available in similar colours
• Loadings on the substrate and building exterior are reduced for a complete solution
in comparison with naturally quarried stone • Independently tested system, including CWCT external
• The Ceramic Granite is completely resistant to light and building envelope
uV radiation • Available with the Total Benchmark Guarantee
• The Ceramic Granite is highly resistant to algae growth • Manufactured and supplied under a quality system certified
and does not accumulate dust to bS En iSO 9001: 2000
• Virtually maintenance free • Manufacturing plants are ISO 14001 (Environmentally) accredited bEnCHMARK For more information
on this product
www.kingspanbenchmark.com/products/wall/ceramic
+44 (0) 800 970 9036 (UK) +353 (0) 42 969 8529 (Ireland)
TEChnICal
CERAMiC CEraMIC GranITE | 15
9. CEraMIC TIlE
CEraMIC CEraMIC TIlE
TEChnICal ovErvIEW
Material Description Dimensions
The Ceramic Tile is an extruded ceramic panel according to Din There are five different tile sizes available: 400x200mm,
En 14411: 2003 (Ceramic tiles Annex g (Dry-pressed ceramic 500x250mm, 500x280mm, 600x250mm and 600x280mm.
tiles with low water absorption group bla)), fired at 1250ºC. Face panel thickness: 15mm maximum.
product Tolerance Façade & rail Weight
Thickness, sides straightness, rectangularity and surface flatness Module size is dependant on project design requirements.
are all in accordance with Din En 14411: 2003. There is a natural For accurate weights for your specific application, contact the
material tolerance, hence colour can vary. benchmark Technical Services Department.
aluminium Secondary rail System
The extruded aluminium secondary rail system conforms to
bS En 12020-1: 2008 (Aluminium and aluminium alloys.
Extruded precision profiles in alloys En AW-6060 T66.
Technical conditions for inspection and delivery).
attachment
Ceramic Tiles are put into position using a mounting tool.
The secondary rail system is securely fastened to the benchmark
Karrier panel with expanding self-fixing aluminium and stainless
steel fasteners.
Fire
The Ceramic Tile façades have a Class A1 rating, and are
non-combustible as defined by building Regulations.
InTroDUCTIon
Colours
Ceramic Tile is the ideal choice for creating a in addition to its aesthetics, the system provides a cost-effective
Most popular colours are shown on page 49. glazed and unglazed
solution. The façade is fast to install, easy to integrate and
contemporary, stylish façade. Tiles are available fully guaranteed.
options are available. please see the web page below to see the
in a large range of surfaces and sizes to full range.
support endless design possibilities. Build options
please refer to build option 1, shown on page 6.
BEnEFITS
• Offers design flexibility • Comprehensive design and technical support
• Easily integrates with other façades • Flashings and ancillaries are available in the same material
• Fast and simple installation for a complete solution
• Secret fix only, individual tiles clip onto the railing system • Independently tested system, including CWCT external
• Has a hydrotect surface coating, ensuring an ageless building envelope
appearance, long term minimum maintenance and is able • Available with the Total Benchmark Guarantee
to remove harmful oxides from the atmosphere • Manufactured and supplied under a quality system certified
• Frost proof to bS En iSO 9001: 2000
• Light and colour-fast, resistant to UV light • Manufacturing plants are ISO 14001 (Environmentally)
• Low water absorption (3% < E > 6%) accredited
• Resistance to aggressive environmental effects
bEnCHMARK For more information
on this product
www.kingspanbenchmark.com/products/wall/ceramic
+44 (0) 800 970 9036 (UK) +353 (0) 42 969 8529 (Ireland)
TEChnICal
CERAMiC CEraMIC TIlE | 17
10. naTUra pro, TExTUra
& pICTUra CEMEnTITIoUS BoarDS naTUra pro, TExTUra & pICTUra
TEChnICal ovErvIEW
Material Description Dimensions
Cementitious boards are fibre-reinforced cement boards that Maximum module available after trimming by fabricator (including
satisfy the requirements of Category A, Class 2 to bS En 12467: 10mm joint) is 2500 x 1250, 3100 x 1250 and 3100 x 1500*.
2004 (Fibre-cement flat sheets). panels are manufactured by a Face panel thickness: 8 mm / 12mm.
batch-blending operation, followed by the Hatchek process and *Only avilable in the Textura board.
high-pressure steam autoclaving.
Façade & rail Weight
product Tolerance Module size, thickness and railing are dependant on project design
Boards have a thickness tolerance of +/- 10%. requirements. For accurate weights for your specific application,
contact the benchmark Technical Services Department.
aluminium Secondary rail System
Secret Fix - The extruded aluminium straps or hooks, in 6063/T6
conforming to bS En 12020-1: 2008 grade alloy, are secured to the
boards using undercut stainless-steel expanding anchors. These are
secured to the aluminium secondary rail system using self-drilling /
self-tapping stainless steel fasteners. The secondary rail system is
securely fastened to the benchmark Karrier panel with expanding
self-fixing aluminium and stainless steel fasteners.
Through Fix - The boards are secured to the aluminium rail
system using coloured aluminium rivets. The rail system is securely
fastened to the benchmark Karrier panel with expanding self-fixing
aluminium and stainless steel fasteners.
Fixings
InTroDUCTIon
Rivets and screws are available in the same colour as the panel,
Architectural cementitious boards offer the A uV cured top layer (excluding Textura) offers good to disguise the fixings.
protection against many types of staining, against mechanical
designer subtle shades of colour along with the damage during construction and against graffiti.
Fire
crisp, clean lines required to create dynamic The cementitious boards achieve a Class 0 to bS476 - 6: 1989
Where a smooth unbroken surface is required, a concealed (Fire propagation for products) and bS476 - 7: 1997 (Surface
and attractive elevations. fixing option and a through fixing detail are available. spread of flame of products) and have a European fire classification
Smooth, granular and matt finishes are available, which allow of A2-s1, d0.
natural variegation of the fibre cement finish.
Colours
please refer to pages 50 and 51 to see the natura pro, Textura &
BEnEFITS pictura colours.
• Smooth, granular or matt surfaces are available • Individual modules can be removed and replaced as necessary Build options
• A wide range of colour options are available • Comprehensive design and technical support
please refer to build option 1, shown on page 6.
• Choice of subtle pigmented surfaces • Flashings and ancillaries are available in similar colours
• Easy to install for a complete solution
• Excellent weather resistance • Independently tested system, including CWCT external
• Resistant to insects, mould growth and fungi building envelope
• Virtually maintenance free • Available with the Total Benchmark Guarantee
• Frost proof • Manufactured and supplied under a quality system certified
• Provides excellent weather protection to the building envelope to bS En iSO 9001: 2000
• Secret fix and through fix options are available. • Manufacturing plants are ISO 14001 (Environmentally) accredited bEnCHMARK For more information
on this product
www.kingspanbenchmark.com/products/wall/
cementitious-boards
• Cementitious boards are BBA certified. TEChnICal +44 (0) 800 970 9036 (UK) +353 (0) 42 969 8529 (Ireland)
CEMEnTiTiOuS bOARDS naTUra pro, TExTUra & pICTUra | 19
11. TIMBEr
WooD TIMBEr
TEChnICal ovErvIEW
Material Description Dimensions
Sustainable source natural timber, varying from hard to softwood, Lengths can range from 1.2m to 6.0m but can vary from specie to
cut to order. specie. please contact the benchmark Technical Department for
further information.
product Tolerance
Face panel thickness: 21mm (Siberian Larch, Sweet Chesnut
Timber machine cutting tolerances of +/- 0.5mm for the width and
& Accoya), 18mm (Western Red Cedar).
thickness, and a cross cutting to set length +/- 1mm.
Façade Weight
Fixings
Module size, thickness are dependant on project design
Stainless steel fixings ideally small round headed annular ring
requirements. For accurate weights for your specific application,
shank nails.
contact the benchmark Technical Services Department.
note: non ferrous metals should not be used with Western
Red Cedar.
Fire
Fire ratings can vary from specie to specie, please refer to the
website for guidance.
Colours
Siberian larch – pale honey to Reddish-brown. Relates to the
heartwood of the species. Most timbers vary in colour and will
change with use, the application of finishes and exposure to light.
Sweet Chestnut – pale golden brown to biscuit, some dark
brown stain can be present, ages to silver grey if left unprotected.
InTroDUCTIon accoya – pale cream with brownish tones, allowing light
translucent colours to be applied.
benchmark timber provides a natural Timber is available in Accoya, Siberian Larch, Sweet Chestnut
Western red Cedar – Reddish brown (Ages to silver grey if left
and Western Red Cedar. Lightweight and fast to install the
look to your building with warm colours façade is an ideal solution for fast-track building schemes.
unprotected).
and textures. Build options
please refer to build option 1, shown on page 6.
BEnEFITS
• Sourced from sustainable forests with PEFC (Programme • Secret fix and through fix options are available
for the Endorsement of Forest Certification) or FSC • Comprehensive design and technical support
(Forest Stewardship Council) certification • Ancillaries are available in the same material for a
• Available in transparent and opaque coatings on a wide variety complete solution
of timber substrates, including fire retardant treatments • Independently tested system, including CWCT external
• Virtually maintenance free building envelope
• Retains natural strength & beauty • Available with the Total Benchmark Guarantee
• Environmentally compatible, 100% recyclable and naturally • All manufacturing occurs under strict quality control guidelines,
renewable providing high performance materials
• Provides excellent weather protection to the building envelope
bEnCHMARK For more information
on this product
www.kingspanbenchmark.com/products/wall/wood
+44 (0) 800 970 9036 (UK) +353 (0) 42 969 8529 (Ireland)
TEChnICal
WOOD TIMBEr | 21
12. WooD CoMpoSITE
WooD WooD CoMpoSITE
TEChnICal ovErvIEW
Material Description Build options
Wood Composite façades have a thermosetting phenolic resin please refer to build option 1, shown on page 6.
bonded cellulose fibre core. This is faced with natural wood that
Dimensions
has been coated with a proprietary acrylic resin - pVDF uV
Maximum module 1206mm length x 606mm height (inclusive
protective finish.
of 8mm joint) and maximum actual panel size 1198mm length
natural Wood x 598mm height.
The natural wood is typically Ayous or Okume and comes from Face panel thickness: 10mm maximum.
a sustainable source.
Façade & rail Weight
anti Graffiti Railing system is dependant on project design requirements.
Specifically designed to resist chemical attack (anti graffiti), For accurate weights for your specific application, contact the
the Wood Composite façade is bM Trada Q Marked benchmark Technical Services Department.
(Cert CE/F04151).
product Tolerance
Thickness, length and width, edge straightness and squareness
are all in accordance with bS En 438 (High-pressure decorative
laminates (HpL) Sheets based on thermosetting resins (usually
called Laminates) part 2: Determination of properties).
aluminium Secondary rail System
The extruded aluminium secondary rail system is tested to
bS 1474: 1987 (Specification for wrought aluminium and aluminium
alloys for general engineering purposes) in 6063/T6 grade alloy.
InTroDUCTIon
attachment
The Wood Composite façade is a high The panels are coated with a proprietary coating, based in
The extruded aluminium straps tested to bS 1474 in 6063/T6
synthetic resins and pVDF, which protect the panel from the
pressure laminate cladding manufactured effects of sunlight, chemical attack (anti-graffiti) and the damage
grade alloy are secured to the Wood Composite façade panel using
with a real wood veneer which exhibits caused by atmospheric agents.
undercut stainless steel expanding anchors. Straps are secured to
the aluminium secondary rail system using self drilling / self tapping
all the natural variation, warmth and beauty A smooth concealed fixing system can be used, and a through fix stainless steel coated black screws.
of real wood. option also available to create the desired look.
Fire
The Wood Composite façade panels have a Class 3 fire rating to
BEnEFITS bS476 - 6: 1989 (Fire propagation for products) and bS476 - 7:
1997 (Surface spread of flame of products). Class 1 fire rating to
• The natural wood veneer is sourced from sustainably • Secret fix and through fix options are available
bS476 - 6:1989 and bS476 - 7: 1997 are available which are Class
managed forests • Individual modules can be removed and replaced as necessary
0 as defined by building Regulations and have a European fire
• Graffiti proof, specifically designed to resist chemical attacks • Comprehensive design and technical support
classification of b-s2, d0.
• 10 year colourfast guarantee to Class 3 according to • Flashings and ancillaries are available in similar colours
bS En 20105-A02: 1995 (Textiles. Tests for colour fastness. for a complete solution Colours
grey scale for assessing change in colour) • Independently tested system, including CWCT external please refer to page 52 to see the range.
• Independent durability and weathering tests completed by building envelope
Taylor Woodrow to recognised industry standards • Available with the Total Benchmark Guarantee
• Available in a range of colours • Manufactured and supplied under a quality system certified
• Virtually maintenance free
• Provides excellent weather protection to the building envelope
to bS En iSO 9001: 2000
• Manufacturing plants are ISO 14001 (Environmentally) accredited
bEnCHMARK For more information
on this product
www.kingspanbenchmark.com/products/wall/wood
+44 (0) 800 970 9036 (UK) +353 (0) 42 969 8529 (Ireland)