11. SPECIFICATIONS
3
(2)FR-E500
n 3-phase 200V power supply
Type FR-E520- K (C) (Note 8) 0.1K 0.2K 0.4K 0.75K 1.5K 2.2K 3.7K 5.5K 7.5K
Applicable motor capacity(kW) (Note 1) 0.1 0.2 0.4 0.75 1.5 2.2 3.7 5.5 7.5
Rated capacity (kVA) (Note 2) 0.3 0.6 1.2 2.0 3.2 4.4 7.0 9.5 13.1
Rated current (A) (Note 6)
0.8
(0.8)
1.5
(1.4)
3
(2.5)
5
(4.1)
8
(7)
11
(10)
17.5
(16.5)
24
(23)
33
(31)
Overload capacity (Note 3) 150% 60 seconds 200% 0.5 seconds (inverse-time characteristics)
Output
Voltage (Note 4) Three phase, 200V to 240V 50Hz/60Hz (280VDC, Note 7)
Rated input AC (DC) voltage, frequency Three phase, 200V to 240V 50Hz/60Hz (252 to 310VDC, Note 7)
Permissible AC (DC) voltage fluctuation 170 to 264V 50Hz/60Hz
Permissible frequency fluctuation ±5
Powersupply
Power supply system capacity (kVA)
(Note 5)
0.4 0.8 1.5 2.5 4.5 5.5 9 12 17
Protective structure (JEM1030) Enclosed type (IP20), IP40 for dirt-protection structure series
Cooling system Self-cooling Forced air cooling
Approximate weight (kg) 0.6 0.6 0.8 1.0 1.7 1.7 2.2 4.4 4.9
n Single-phase 200V power supply
Type FR-E520S- K 0.1K 0.2K 0.4K 0.75K
Applicable motor capacity(kW) (Note 1) 0.1 0.2 0.4 0.75
Rated capacity (kVA) (Note 2) 0.3 0.6 1.2 2.0
Rated output current (A) (Note 6) 0.8(0.8) 1.5(1.4) 3.0(2.5) 5.0(4.1)
Overload capacity (Note 3) 150% 60 seconds 200% 0.5 seconds (inverse-time characteristics)
Output
Rated output voltage (Note 4) Three phase, 200V to 240V 50Hz/60Hz
Rated input AC voltage, frequency Single phase, 200V to 240V 50Hz/60Hz
Permissible AC voltage fluctuation Single phase, 180 to 264V 50Hz/60Hz
Permissible frequency fluctuation Within ±5%
Power
supply
Power supply capacity (kVA) 0.5 0.9 1.5 2.5
Protective structure (JEM1030) Enclosed type (IP20)
Cooling system Self-cooling Forced air cooling
Approximate weight (kg) 0.6 0.6 1.0 1.7
Note:1. The applicable motor capacity indicated is the maximum capacity applicable when a Mitsubishi 4-pole standard motor is used.
Normally, the rated current (at 50Hz) of the motor applied should not exceed the rated current.
2. The rated output capacity indicated assumes that the output voltage is 230V for 200V class and single-phase 200V class.
3. The overload capacity indicated in % is the ratio of the overload current to the inverter's rated current. For repeated duty, allow
time for the inverter and motor to return to or below the temperatures under 100% load.
4. The maximum output voltage does not exceed the power supply voltage. The maximum output voltage may be set as desired
below the power supply voltage. Use the power supply capacity larger than the indicated.
5. The power supply capacity changes with the values of the power supply side inverter impedances (including those of the input
reactor and cables).
6. The rated output current in the parentheses applies when low acoustic noise operation is to be performed at the ambient
temperature higher than 40°C (30°C for the dirt-protection structure) with the Pr. 72 (PWM frequency selection) value set to
2kHz or higher.
7. When using a DC power supply
(1) The guideline for the power supply voltage fluctuation range is 280VDC ±10%, but usually use the power supply at or below
300VDC.
(2) When DC power is switched on, a larger inrush current flows than in AC power. The number of power-on times should be
minimized.
(3) 300VDC must be reserved to make the torque characteristic equal to when an AC power supply is used.
8. The type code of the dirt-protection structure series ends with C.
18. SPECIFICATIONS
10
FR-E500 FR-A024/A044 FR-U100
0.1K to 0.75K (4 models) 0.1K to 0.4K (3 models)
0.1K to 0.75K (4 models) 0.1K to 0.75K (4 models)
0.1K to 7.5K (9 models) 0.1K to 3.7K (7 models) 0.1K to 1.5K (5 models)
0.4K to 7.5K (7 models) 0.4K to 3.7K (5 models)
Soft-PWM control
High carrier frequency sine-wave PWM
High carrier frequency sine-wave PWM
Sine-wave PWM
High carrier frequency sine-wave PWM for
low acoustic noise series
General-purpose magnetic flux vector
control
V/F control selectable
General-purpose magnetic flux vector
control
V/F control selectable
V/F control
IPM (IGBT) IPM (IGBT) IGBT
Ultralow noise Ultralow noise
Non-low noise or ultralow noise
(low acoustic noise series)
0.7kHz to 14.5kHz with Soft-PWM
(Value set is an integer between 0 and 15)
(Factory setting 1kHz, Soft-PWM mode)
0.7kHz to 14.5kHz
(Value is set in 0.1kHz increments)
(Factory setting 1kHz)
Approx. 1kHz
(0.7kHz to 14.5kHz (factory setting 7kHz)
for low acoustic noise series)
20% (capacitor regenerated, 0.1K or
more)
20% (capacitor regenerated, 0.1K or
more)
20% (capacitor regenerated, 0.1K or
more)
20% (capacitor regenerated) 20% (capacitor regenerated)
10ms 10ms 10ms
Provided as standard Provided as standard ×
Max. 15 speeds (without compensation)
Speed can be varied during operation
Max. 15 speeds (without compensation)
Speed can be varied during operation
Max. 15 speeds (without compensation)
Speed can be varied during operation
× × ×
¡ ¡ ×
¡ × ×
¡ × ×
× × ×
× × ×
× × ×
× × ×
¡ × ×
¡ × ×
¡ ¡ ¡
Operation panel equipped as standard
FR-PU04 parameter unit available as
option (FR-PU04 has a backlit LCD)
Some models have the FR-PU03
parameter unit as standard.
No (key sheet equipped as standard)
PU operation type may only be
connected.
¡ × ×
× × ×
×
(Made available by using the FR-PU04
parameter unit)
×
(Made available by using the FR-ARW03
parameter copy unit)
×
Operation panel: No language display
FR-PU04: 8 languages (Japanese, English,
German, French, Spanish, Italian, Swedish,
Finnish)
FR-PU03: Japanese
FR-PU03E: English
Key sheet: Japanese
Cannot be used Cannot be used Cannot be used
Cannot be used May be used (with restrictions) Cannot be used
Cannot be used May be used May be used (PU operation type only)
May be used Cannot be used Cannot be used
Cannot be used Cannot be used Cannot be used
May be used Cannot be used Cannot be used
chapter1
20. SPECIFICATIONS
12
FR-E500 FR-A024(S)/A044 FR-U100
RS-485 provided as standard
CC-Link compatible model available for
three-phase 200V class.
FR-E5NC plug-in option available for use
with three-phase 400V class for
compatibility with CC-Link.
Made available by using the FR-CU03
external option
×
11 different functions selectable
Assignable to 4 terminals
10 different functions selectable
Assignable to 4 terminals
9 different functions selectable
Assignable to 3 terminals (multi-function
product only)
12 different functions selectable
Assignable to 2 terminals
5 different functions selectable
Assignable to 2 terminals
3 different functions selectable
Assignable to 1 terminal (multi-function
product only)
12 different functions selectable
Assignable to 1 terminal (A, B, C)
× ×
¡ ¡ ¡(multi-function product only)
¡
(PC terminal is used as power supply)
× ×
×
(¡ Enabled for 400V class)
× ×
× × ×
DC0 to 5V,0 to 10V
DC4 to 20mA
Built-in analog potentiometer
DC0 to 5V,0 to 10V
DC4 to 20mA
DC0 to 5V
Plug-in screw type terminals
Screw type terminals
(Solderless terminals usable)
Plug-in type terminals
Screw type terminals
(Solderless terminals usable)
Screw type terminals
(Solderless terminals usable)
Plug-in type terminals
× × ×
¡ × ×
×
(¡ One option may be fitted to 400V class)
× ×
¡
×
(However, communication software is
available)
×
¡ ¡ ¡
¡ × ×
¡ ¡ ×
There is mounting compatibility with U100
series
No compatibility with A024 series
22. SPECIFICATIONS
14
(2)FR-E500
• Single-phase 200V power input
R
S
NFB MC
Power
supply
(L1)
(L2)
• 3-phase 200V power input
U
V
W
(Note 1)
P PR
(Note 2) +
R
TR
(Note 4)
IM
R
S
T
POWER
STF
STR
RH
RM
RL
MRS
RES
(Note 3)
CPU
CON
+5V
SD
10
2
5
4
+5V
RUN
FU
SE
(Note 6)
4 to 20mA DC
NFB
A
B
C
FM
SD
(Note 4)
RA
PC
+24V
MODE SET REV •£
•¥STOP
RESET
FWD
Hz
A
PU
RUN
MON
EXIT
MAX
MIN
MC
N
C
P1
Power
supply
Forward rotation
Reverse rotation
Multi-speed
selection
(Note 5)
Output stop
(Note 5)
Reset
Frequency
setting
potentiometer
Analog common
Brake resistor (option)
Converter Inverter
Control
power
supply
Voltage
detection
Current
detection
Gate drive
circuit
Protection
circuit
Judgment
circuit
PWM
circuit
Option
connector
Gate
array
Operation panel
Motor
Ground
Ground
Alarm output
(Note 6)
Frequency meter
Calibration
resistor
Note: 1. The FR-E520-0.1K and 0.2K can not use a brake resistor and do not contain a transistor.
2. Provided for the FR-E520-2.2K to 7.5K
3. Not needed when the operation panel or parameter unit is used for calibration.
4. Always earth the inverter and motor.
5. Input terminal function selection allows terminal functions to be assigned individually.
6. Output terminal function selection allows terminal functions to be assigned individually.
(Note 1)
R
(L1)
(L2)
(L3)
(+) (−)
26. SPECIFICATIONS
18
Corresponding
Model
Terminal
Symbol
Terminal
Name
Rating, etc. Description
A500 E500
Refer to
Section
CS
Automatic
restart after
instantaneous
power failure
selection
terminal
Input resistance 4.7kΩ
Voltage 21 to 27VDC
when open
4 to 6mADC when
shorted
Photocoupler isolated
Controllable by open
collector output or
no-voltage contact
signal
Short CS-SD to enable automatic restart
control when power is restored from an
instantaneous power failure (no limit to
power failure period).
Keep terminals CS-SD open if automatic
restart operation after power restoration from
an instantaneous power failure causes
trouble for the machine.
¡
(Note 3)
1.4.13
SD
Contact
input
common
terminal
Common terminal for the contact input
signals and frequency meter.
Isolated from the common of the control
circuit in A500 .
Not isolated from terminal 5 in E500
(isolated in three-phase 400V class). Isolated
from terminal SE.
¡ ¡ 1.4.19
PC
External
transistor
common
terminal,
24VDC
power
supply
Power supply voltage
range
22 to 26VDC
Current consumption
100mA
When inputting the transistor output (open
collector) having an external power supply,
e.g. a programmable controller (PC), to the
inverter, connect the positive common of the
external power supply to prevent a
malfunction due to leakage current.
Terminals PC-SD can be used as a 24VDC,
0.1A power output.
When source logic is chosen for A500 ,
this terminal acts as a contact input common.
¡ ¡ 1.4.15
10
5V±0.2VDC
Permissible load
current 10mA
¡ ¡
10E
Frequency
setting
power
supply
terminals
10V±0.4VDC
Permissible load
current 10mA
Used as a power supply when a frequency
setting (speed setting) potentiometer is
connected externally.
(Terminal 5 is a common) ¡
When 5VDC is chosen for the input voltage
of terminal 2 in Pr. 73, entering 0 to 5VDC to
terminal 2 provides the maximum output
frequency at 5V, making I/O proportional.
(Even an input voltage over 5V is regarded as
5V.)
¡
2
Frequency
setting input
terminal
(Voltage
signal)
Input resistance
10kΩ±1kΩ
Maximum permissible
voltage 20VDC
When 10VDC is chosen for the input voltage
of terminal 2 in Pr. 73, entering 0 to 10VDC
to terminal 2 provides the maximum output
frequency at 10V, making I/O proportional.
(Even an input voltage over 10V is regarded as
10V.)
¡
¡
1.4.6
Controlcircuit(inputsignals)
5
Frequency
setting input
common
terminal
Common terminal for frequency setting
signals and 0V for the control circuit.
Do not earth this terminal to the ground.
¡ ¡