Our iSC™ range of intelligent sensors has been developed in house, by our control engineers to offer unique solutions in sensing technology which is not available from the major manufacturers. We are able to offer combined sensors with 0/10v outputs as traditional sensors, or with BACnet communications which give a modulating control signal to end devices such as our window actuator controller - thus saving cabling back to control panels.
Our room sensor range has been specifically designed for ease of use by the client with some model shaving push button overrides and LED indication of status with clear labelling - not complicated menu driven hard to use/ read liquid crystal displays as the major manufacturers units.
Purpose designed and manufactured in the UK, an all-in-one unit.
Should be specified for fan coil, zone control applications and natural ventilation control.
CO2 uses the latest dispersive infrared cell.
Anti-microbial™ front face touch membrane - helps eliminate bacteria.
Wiring costs reduced by having the intelligent sensor with outputs within the controlled space - saving at least 20% of installation costs on a typical 10 room scheme against hard wiring with conventional sensors.
Humidity, CO2, temperature, LED traffic lights, Extension times, Alarm Unit and push button controls options.
Available with BACnet communications or dedicated 0/10v outputs.
2 x 0/10v analogue outputs (10mA) which by using your favourite BACnet master controller you can write your own software logic to suit the application using the items selected from the BACnet object list.
Unique space saving surface mounted design with pre-wireable base and plug-on fascia plate assists in easy installation.
Energy saving power supply.
Back box with BESA fixing holes designed to be fitted and wired prior to decoration.
Designed with unique ventilation slots - increases air flow and sensing accuracy.
Intelligent Sensors
Intelligent BACnet Room Setpoint Unit (iTSP)
Intelligent Temperature and CO2 BACnet Sensor (iTC)
Intelligent Temperature and CO2 BACnet Sensor with CO2 Level Indicator (iTCl)
Intelligent Temperature and CO2 BACnet Sensor with manual override (iTCm)
Intelligent Temperature and CO2 BACnet Sensor with manual override and CO2 Level Indicator (iTCml)
Intelligent Temperature and RH BACnet Sensor (iTH)
Intelligent Temperature and RH BACnet Sensor with manual override (iTHm)
Intelligent Temperature BACnet Sensor (iT)
Intelligent Temperature BACnet Sensor with manual override (iTm)
Standalone Sensors
Room Temperature and CO2 Sensor (STC)
Room Temperature and RH Sensor (STH)
Room Temperature and RH Sensor with manual override (STHm)
Room Temperature Sensor (ST)
Temperature and CO2 Sensor with CO2 Level Indication (STCl)
Temperature and CO2 Sensor with manual override (STCm)
Temperature and CO2 Sensor with manual override and CO2 Level Indicati
1. K
U
e
th
in
e
d
a
M
Natural Ventilation
Control Solutions
Standalone Controller Range
2. Manual Positioning Unit
Low voltage 24V AC/DC operation, Wall/Control panel mountable.
0-10VDC signal Optional rain sensor to automatically
Louvres/Dampers can be manually close louvres/dampers where
positioned to one of six positions at necessary.
anytime, including fully open and fully Can operate multiple
closed. Louvres/Dampers depending on
Optional auto close energy saving power supply unit rating.
feature.
LED feedback display of
louvre/damper position selected.
Standard Power Supply Unit sizes
PSU8 up to 8 Actuators
PSU30 up to 30 Actuators
Other Sizes Available on Request
“ Our iSC™ range of intelligent
sensors has been developed in
house, by our control engineers
”
3. Standalone Controllers
C: Controller, T: Temperature, C: Carbon Dioxide,
m: Manual Push Buttons, I: CO2 Indication
CTCml:
Temperature and CO2 Sensor Controller with manual
override and CO2 Level Indicator
CT:
Temperature Room Controller
CTC:
Temperature and CO2 Room Controller
CTm:
Temperature Room Controller with Manual Override
CTCm:
Temperature Room and CO2 Controller with Manual
Override
CTCI:
Temperature and CO2 Controller with CO2 level
indication
4. Standalone Controllers
Our unique range of standalone controllers can control Ventilation Dampers or
Automated Windows together with localised Heating, via on board, Temperature or
Optional CO2 Sensors to suit the requirements of each specific application. These
Controllers can be linked to either a time clock or receive a time signal from a BMS to
activate the optional Night Cooling programme (Night Cooling only available with the
Manual Override options).
0/10 VDC Heating Signal
0/10 VDC Cooling/Ventilation
Signal
Frost Protection
Room Temp Set Point Adjustable
19°C to 26°C
Room CO2 Set Point Adjustable
900ppm to 1600ppm
Pre-wireable base and plug-on
fascia plate assists in easy, time
saving installation
“ Our room sensor range has been
specifically designed for ease of use
by the client
”
5. Standalone Controllers
Temperature Control:-
The room set point for the control of the Ventilation Dampers/Automated Windows can
be adjusted in 1°C increments between 21°C and 26°C with a seasonal change over
and a night cooling option if a time clock or BMS time signal is available. Localised
Heating can also be controlled and is set 2°C below the room set point.
Manual Override (optional):-
Each room device has manual override capabilities which give the end user control of
the ventilation strategy to suit the room application. The device consists of two push
buttons and three LED lights, the push buttons enable the end user to open or close
the ventilation as required, the LED’s give an indication that the system has either been
overridden or is in Auto mode. Once the system has been overridden it will stay in that
mode for 30 minutes, after this time the system will revert back to Auto mode.
CO2 Indication (optional):-
Each room device can also be fitted with a further 3 LED’s to identify the level of CO2
within the space; these are green, amber and red. With green being healthy and red
being high levels of CO2 ppm`s.
Night Cooling:-
To enable the Night Cooling pre-programmed software, the device needs to be in
(Night Mode) and the night cooling enabled, this then cools the building to just below
the room set point. When the Time Switch is in (Night Mode), by holding down the
open/close buttons this will enable this mode to be turned on/off. (Indicated by the
Auto LED ON or OFF).
Summer/Winter:
The Summer set point can be selected to be below the Winter set point, this is 2°C
below that set value on the dip switches. To select Summer mode, in (Day Mode) hold
both the open/close buttons down for 5 seconds, lights flash, push the open button for
summer mode, or close button for winter mode.
6. Four Zone Power Supply Unit (PSU)
+ Time Switch (TS) Interface Unit
230V Fused Spur
Ventilation
Damper/Window
ZONE 2 ZONE 3 ZONE 4
Heating Valve
(optional)
Room Controller ZONE 1
This interface unit comprises of a power supply, coded terminals, frost protection
feature, optional digital time switch and night cooling (operated by the time switch or
external VFC)
7. Window Control
The Window Control Module contains a 24v DC Power Supply and an iWAC module
per Window Actuator that controls via a 0/10 VDC positioning signal from a suitable
controller. The WCM features an intelligent ‘self stroking’ operation and controls the 24v
DC window actuator in steps to prevent noise disturbance to end users.
The Window Control Module allows only one window to operate at a time. This saves
the expense and space in only needing a DC power supply rated for the largest
actuator (maximum 3 Amp per controller) to be operated.
230V Fused Spur
Window
Actuator
ZONE 2 ZONE 3 ZONE 4
Heating Valve
(optional)
Room Controller
ZONE 1
8. The All New NV8 Natural Ventilation
Controls Package - As easy as ABC
SEE LIVE DEMO: http://217.41.89.69:5445
Username: Visitor
Password: Site123 (Case Sensitive)
A: ONE Control Panel
B: ONE Pair of Cables
C: ONE Combined Room Unit#
D: ONE Power Supply#
E: ONE Set of
Louvres/Window#
F: ONE Modular Wiring Install
G: ONE Web Browser
H: ONE Web Browser Page for
Settings
I: ONE Web Browser Page for
Time Programs
J: ONE Onboard Proven and
Tested Software Protocol
K: ONE Open Source BACnet
Communication Protocol
L: ONE BACnet over IP output
M: EIGHT Zones
# Per Zone
0844 809 2509
info@airtherm.co.uk | www.airtherm.co.uk