Honeywell’s VISTA-50P Control Panel provides the flexibility of up to eight independent partitions with the economy
of a single control.


FEATURES

Dependable features to meet your most                         End users will appreciate the easy-to-use
demanding installations:                                      convenience and control features of the VISTA-50P:

• Nine hardwired zones standard                               • Wireless remote controls
                                                               (featuring single button system operation):
• Expandable to 87 total zones
                                                               — 5804 - Four-Button Wireless Key
• Eight partitions standard                                    — 5804BD - Bidirectional
• 75 user codes work in all partitions                            Four-Button Wireless Key with
                                                                  system status feedback
• Seven authority levels
                                                              • Single or dual-button wireless
• 224 event memory log/printer option
                                                               personal panic:
• Four trigger outputs                                         — 5802MN
                                                               — 5802MN2
• 5800 Series wireless compatibility
                                                              • Home control features activate lights, appliances,
• Supports two-wire multiplex
                                                               garage doors and numerous other devices
• Scheduling of events (real time clock)
                                                              • The VISTA Interactive Phone Module (VIP) gives the
• Keypad macro features                                        end-user control of their system from any touchtone
• Master console option for viewing all                        phone. The 4286 VIP responds in English, with a
 partitions at a glance                                        vocabulary of over 100 words

• Common lobby logic                                          • Full English display keypads for clear understanding
                                                               of system status and zone locations
• Fast downloading
                                                              • Timed event applications:
• Supports up to 16 relays and/or X-10
                                                               — Opens garage doors and
• Quick start programming                                         turns on lights
                                                               — Provides“lived-in look” while
• False alarm features
                                                                  away from home
• UL Commercial Burglary listed                                — Ability to limit access to parts of the
 (VISTA-50PUL)                                                    home at certain times
VISTA-50P
CONTROL PANEL

SPECIFICATIONS

Electrical                                 • Programmable swinger suppression                     • Duct Detectors

• Aux power 12VDC, 750mA max               Communications                                         • Serial Printer

• 16.5 VAC/40 VA transformer               • Touchtone or pulse                                   • Polling Loop Devices

• Alarm output 12VDC,                      • Formats supported: ADEMCO                            • Key Switch Devices
 1.7 Amps max                                Contact ID, ADEMCO 4 + 2 Express,
                                                                                                  Wireless Receiver Systems
                                             ADEMCO low speed
• For UL installations, combined
                                                                                                  • 5800 Series
 Aux and alarm output cannot exceed        • 3+1, 4+1 and 4+2 reporting
                                                                                                    — 5881ENL up to 8 zones-50mA
 750mA
                                           • Reporting capabilities: Split,                         — 5881ENM up to 16 zones-50mA
Output Control                               Dual, Split/Dual                                       — 5881ENH up to 26 zones-50mA

• Supports up to four relay boards         • Low battery reports 11.2-11.6VDC                     • All Receivers Support:
 (Part No. 4204)                                                                                    — Diversity reception with
                                           • Expanded reporting
                                                                                                       two antennea
• Each board supports four relays
                                           • Up to four digit PABX                                  — Remote mounting for
 for a total of 16
                                             codes supported                                           best location
• Optional X-10 interface (Part No.                                                                 — Use of second receiver for
                                           • True dial tone detection
 4300) may be used to control                                                                          maximum coverage or
 X-10 receiving devices                    • Double pole line seizure                                  tough installations
• Each X-10 receiver address               • AC loss and restoral                                   — Unique supervision and low
 counts as one relay when computing          reporting supported                                       battery indications by point
 total relays                              Supported Devices                                      Transmitters
• Real time clock can be used for          Hardwired Expansion Devices                            • 5800 Series
 relay/X-10 control                        • 4208U Eight-Zone                                       — Three volt Duracell lithium batteries
Zones                                        Expansion Module                                       — One mile range
                                                                                                    — Tamper standard
• Nine hardwired zones                     • Keypads
                                           — 6139 Custom English (required for                    Agency Listings
• Selectable response on zone 9:
                                              programming) -100mA                                 • UL Residential Fire and Burglary
 10MSec or 500MSec
                                           — 6128 Fixed English LCD - 30mA                          and CSFM
• Assignable to any partition
                                           • Voice Module 4286 VIP-160mA                          • UL Commercial Burglary
• 14 zone types to choose from                                                                      (VISTA-50PUL)
                                           • Two-Wire Smoke Detectors


  ORDERING
  VISTA-50P                Control Panel

Automation and Control Solutions
Honeywell Security & Communications
2 Corporate Center Dr. Suite 100
P.O. Box 9040
Melville, NY 11747                                          L/VIS50P/D
                                                            September 2008
www.honeywell.com                                           © 2008 Honeywell International Inc.

Contenu connexe

Plus de Alarm Grid

Leviton vri10 1 lz product manual and setup guide
Leviton vri10 1 lz product manual and setup guideLeviton vri10 1 lz product manual and setup guide
Leviton vri10 1 lz product manual and setup guideAlarm Grid
 
Leviton vri06 1 lz product manual and setup guide
Leviton vri06 1 lz product manual and setup guideLeviton vri06 1 lz product manual and setup guide
Leviton vri06 1 lz product manual and setup guideAlarm Grid
 
Leviton vrf01 1 lz product manual and setup guide
Leviton vrf01 1 lz product manual and setup guideLeviton vrf01 1 lz product manual and setup guide
Leviton vrf01 1 lz product manual and setup guideAlarm Grid
 
Leviton vre06 1 lz
Leviton vre06 1 lzLeviton vre06 1 lz
Leviton vre06 1 lzAlarm Grid
 
Leviton vrcz4 mr, vrcs4-mr, and vrc52-mr product specifications
Leviton vrcz4 mr, vrcs4-mr, and vrc52-mr product specificationsLeviton vrcz4 mr, vrcs4-mr, and vrc52-mr product specifications
Leviton vrcz4 mr, vrcs4-mr, and vrc52-mr product specificationsAlarm Grid
 
Leviton vrcz4 1 l, vrcs4-1l, vrcz1-1l, vrcs1-1l and vrmr1-osg product specifi...
Leviton vrcz4 1 l, vrcs4-1l, vrcz1-1l, vrcs1-1l and vrmr1-osg product specifi...Leviton vrcz4 1 l, vrcs4-1l, vrcz1-1l, vrcs1-1l and vrmr1-osg product specifi...
Leviton vrcz4 1 l, vrcs4-1l, vrcz1-1l, vrcs1-1l and vrmr1-osg product specifi...Alarm Grid
 
Leviton vrcz1 installation manual and setup guide
Leviton vrcz1 installation manual and setup guideLeviton vrcz1 installation manual and setup guide
Leviton vrcz1 installation manual and setup guideAlarm Grid
 
Leviton vrcs1 1 l
Leviton vrcs1 1 lLeviton vrcs1 1 l
Leviton vrcs1 1 lAlarm Grid
 
Leviton vp00 r 10z, vp00r-1lz, vp0sr-10z, vp0sr-1lz installation manual and s...
Leviton vp00 r 10z, vp00r-1lz, vp0sr-10z, vp0sr-1lz installation manual and s...Leviton vp00 r 10z, vp00r-1lz, vp0sr-10z, vp0sr-1lz installation manual and s...
Leviton vp00 r 10z, vp00r-1lz, vp0sr-10z, vp0sr-1lz installation manual and s...Alarm Grid
 
Leviton dimmers, switches and fan speed controllers
Leviton dimmers, switches and fan speed controllersLeviton dimmers, switches and fan speed controllers
Leviton dimmers, switches and fan speed controllersAlarm Grid
 
Fluorescent dimmer for hi lume or eco-10 ballasts
Fluorescent dimmer for hi lume or eco-10 ballastsFluorescent dimmer for hi lume or eco-10 ballasts
Fluorescent dimmer for hi lume or eco-10 ballastsAlarm Grid
 
Controlling z wave door locks with the vrc0 p
Controlling z wave door locks with the vrc0 pControlling z wave door locks with the vrc0 p
Controlling z wave door locks with the vrc0 pAlarm Grid
 
Vizia rf+ collection
Vizia rf+ collectionVizia rf+ collection
Vizia rf+ collectionAlarm Grid
 
Honeywell vista-50p-user-guide
Honeywell vista-50p-user-guideHoneywell vista-50p-user-guide
Honeywell vista-50p-user-guideAlarm Grid
 
Honeywell vista-50p-connections-summary
Honeywell vista-50p-connections-summaryHoneywell vista-50p-connections-summary
Honeywell vista-50p-connections-summaryAlarm Grid
 
Honeywell vista-10p-programming-guide
Honeywell vista-10p-programming-guideHoneywell vista-10p-programming-guide
Honeywell vista-10p-programming-guideAlarm Grid
 
Honeywell total-connect-video-residential-brochure
Honeywell total-connect-video-residential-brochureHoneywell total-connect-video-residential-brochure
Honeywell total-connect-video-residential-brochureAlarm Grid
 
Honeywell lynxrchkit-sc-honeywell-lynxyrchkit-hc-honeywell-lynxrchkit-sha-ins...
Honeywell lynxrchkit-sc-honeywell-lynxyrchkit-hc-honeywell-lynxrchkit-sha-ins...Honeywell lynxrchkit-sc-honeywell-lynxyrchkit-hc-honeywell-lynxrchkit-sha-ins...
Honeywell lynxrchkit-sc-honeywell-lynxyrchkit-hc-honeywell-lynxrchkit-sha-ins...Alarm Grid
 
Honeywell l5100-programming-guide
Honeywell l5100-programming-guideHoneywell l5100-programming-guide
Honeywell l5100-programming-guideAlarm Grid
 
Honeywell wave2ex-data-sheet
Honeywell wave2ex-data-sheetHoneywell wave2ex-data-sheet
Honeywell wave2ex-data-sheetAlarm Grid
 

Plus de Alarm Grid (20)

Leviton vri10 1 lz product manual and setup guide
Leviton vri10 1 lz product manual and setup guideLeviton vri10 1 lz product manual and setup guide
Leviton vri10 1 lz product manual and setup guide
 
Leviton vri06 1 lz product manual and setup guide
Leviton vri06 1 lz product manual and setup guideLeviton vri06 1 lz product manual and setup guide
Leviton vri06 1 lz product manual and setup guide
 
Leviton vrf01 1 lz product manual and setup guide
Leviton vrf01 1 lz product manual and setup guideLeviton vrf01 1 lz product manual and setup guide
Leviton vrf01 1 lz product manual and setup guide
 
Leviton vre06 1 lz
Leviton vre06 1 lzLeviton vre06 1 lz
Leviton vre06 1 lz
 
Leviton vrcz4 mr, vrcs4-mr, and vrc52-mr product specifications
Leviton vrcz4 mr, vrcs4-mr, and vrc52-mr product specificationsLeviton vrcz4 mr, vrcs4-mr, and vrc52-mr product specifications
Leviton vrcz4 mr, vrcs4-mr, and vrc52-mr product specifications
 
Leviton vrcz4 1 l, vrcs4-1l, vrcz1-1l, vrcs1-1l and vrmr1-osg product specifi...
Leviton vrcz4 1 l, vrcs4-1l, vrcz1-1l, vrcs1-1l and vrmr1-osg product specifi...Leviton vrcz4 1 l, vrcs4-1l, vrcz1-1l, vrcs1-1l and vrmr1-osg product specifi...
Leviton vrcz4 1 l, vrcs4-1l, vrcz1-1l, vrcs1-1l and vrmr1-osg product specifi...
 
Leviton vrcz1 installation manual and setup guide
Leviton vrcz1 installation manual and setup guideLeviton vrcz1 installation manual and setup guide
Leviton vrcz1 installation manual and setup guide
 
Leviton vrcs1 1 l
Leviton vrcs1 1 lLeviton vrcs1 1 l
Leviton vrcs1 1 l
 
Leviton vp00 r 10z, vp00r-1lz, vp0sr-10z, vp0sr-1lz installation manual and s...
Leviton vp00 r 10z, vp00r-1lz, vp0sr-10z, vp0sr-1lz installation manual and s...Leviton vp00 r 10z, vp00r-1lz, vp0sr-10z, vp0sr-1lz installation manual and s...
Leviton vp00 r 10z, vp00r-1lz, vp0sr-10z, vp0sr-1lz installation manual and s...
 
Leviton dimmers, switches and fan speed controllers
Leviton dimmers, switches and fan speed controllersLeviton dimmers, switches and fan speed controllers
Leviton dimmers, switches and fan speed controllers
 
Fluorescent dimmer for hi lume or eco-10 ballasts
Fluorescent dimmer for hi lume or eco-10 ballastsFluorescent dimmer for hi lume or eco-10 ballasts
Fluorescent dimmer for hi lume or eco-10 ballasts
 
Controlling z wave door locks with the vrc0 p
Controlling z wave door locks with the vrc0 pControlling z wave door locks with the vrc0 p
Controlling z wave door locks with the vrc0 p
 
Vizia rf+ collection
Vizia rf+ collectionVizia rf+ collection
Vizia rf+ collection
 
Honeywell vista-50p-user-guide
Honeywell vista-50p-user-guideHoneywell vista-50p-user-guide
Honeywell vista-50p-user-guide
 
Honeywell vista-50p-connections-summary
Honeywell vista-50p-connections-summaryHoneywell vista-50p-connections-summary
Honeywell vista-50p-connections-summary
 
Honeywell vista-10p-programming-guide
Honeywell vista-10p-programming-guideHoneywell vista-10p-programming-guide
Honeywell vista-10p-programming-guide
 
Honeywell total-connect-video-residential-brochure
Honeywell total-connect-video-residential-brochureHoneywell total-connect-video-residential-brochure
Honeywell total-connect-video-residential-brochure
 
Honeywell lynxrchkit-sc-honeywell-lynxyrchkit-hc-honeywell-lynxrchkit-sha-ins...
Honeywell lynxrchkit-sc-honeywell-lynxyrchkit-hc-honeywell-lynxrchkit-sha-ins...Honeywell lynxrchkit-sc-honeywell-lynxyrchkit-hc-honeywell-lynxrchkit-sha-ins...
Honeywell lynxrchkit-sc-honeywell-lynxyrchkit-hc-honeywell-lynxrchkit-sha-ins...
 
Honeywell l5100-programming-guide
Honeywell l5100-programming-guideHoneywell l5100-programming-guide
Honeywell l5100-programming-guide
 
Honeywell wave2ex-data-sheet
Honeywell wave2ex-data-sheetHoneywell wave2ex-data-sheet
Honeywell wave2ex-data-sheet
 

Honeywell vista-50p-data-sheet

  • 1. VISTA-50P CONTROL PANEL Honeywell’s VISTA-50P Control Panel provides the flexibility of up to eight independent partitions with the economy of a single control. FEATURES Dependable features to meet your most End users will appreciate the easy-to-use demanding installations: convenience and control features of the VISTA-50P: • Nine hardwired zones standard • Wireless remote controls (featuring single button system operation): • Expandable to 87 total zones — 5804 - Four-Button Wireless Key • Eight partitions standard — 5804BD - Bidirectional • 75 user codes work in all partitions Four-Button Wireless Key with system status feedback • Seven authority levels • Single or dual-button wireless • 224 event memory log/printer option personal panic: • Four trigger outputs — 5802MN — 5802MN2 • 5800 Series wireless compatibility • Home control features activate lights, appliances, • Supports two-wire multiplex garage doors and numerous other devices • Scheduling of events (real time clock) • The VISTA Interactive Phone Module (VIP) gives the • Keypad macro features end-user control of their system from any touchtone • Master console option for viewing all phone. The 4286 VIP responds in English, with a partitions at a glance vocabulary of over 100 words • Common lobby logic • Full English display keypads for clear understanding of system status and zone locations • Fast downloading • Timed event applications: • Supports up to 16 relays and/or X-10 — Opens garage doors and • Quick start programming turns on lights — Provides“lived-in look” while • False alarm features away from home • UL Commercial Burglary listed — Ability to limit access to parts of the (VISTA-50PUL) home at certain times
  • 2. VISTA-50P CONTROL PANEL SPECIFICATIONS Electrical • Programmable swinger suppression • Duct Detectors • Aux power 12VDC, 750mA max Communications • Serial Printer • 16.5 VAC/40 VA transformer • Touchtone or pulse • Polling Loop Devices • Alarm output 12VDC, • Formats supported: ADEMCO • Key Switch Devices 1.7 Amps max Contact ID, ADEMCO 4 + 2 Express, Wireless Receiver Systems ADEMCO low speed • For UL installations, combined • 5800 Series Aux and alarm output cannot exceed • 3+1, 4+1 and 4+2 reporting — 5881ENL up to 8 zones-50mA 750mA • Reporting capabilities: Split, — 5881ENM up to 16 zones-50mA Output Control Dual, Split/Dual — 5881ENH up to 26 zones-50mA • Supports up to four relay boards • Low battery reports 11.2-11.6VDC • All Receivers Support: (Part No. 4204) — Diversity reception with • Expanded reporting two antennea • Each board supports four relays • Up to four digit PABX — Remote mounting for for a total of 16 codes supported best location • Optional X-10 interface (Part No. — Use of second receiver for • True dial tone detection 4300) may be used to control maximum coverage or X-10 receiving devices • Double pole line seizure tough installations • Each X-10 receiver address • AC loss and restoral — Unique supervision and low counts as one relay when computing reporting supported battery indications by point total relays Supported Devices Transmitters • Real time clock can be used for Hardwired Expansion Devices • 5800 Series relay/X-10 control • 4208U Eight-Zone — Three volt Duracell lithium batteries Zones Expansion Module — One mile range — Tamper standard • Nine hardwired zones • Keypads — 6139 Custom English (required for Agency Listings • Selectable response on zone 9: programming) -100mA • UL Residential Fire and Burglary 10MSec or 500MSec — 6128 Fixed English LCD - 30mA and CSFM • Assignable to any partition • Voice Module 4286 VIP-160mA • UL Commercial Burglary • 14 zone types to choose from (VISTA-50PUL) • Two-Wire Smoke Detectors ORDERING VISTA-50P Control Panel Automation and Control Solutions Honeywell Security & Communications 2 Corporate Center Dr. Suite 100 P.O. Box 9040 Melville, NY 11747 L/VIS50P/D September 2008 www.honeywell.com © 2008 Honeywell International Inc.