SlideShare une entreprise Scribd logo
1  sur  61
Télécharger pour lire hors ligne
Envirozone Technocraft Pvt. Ltd

            Presents

     Useful Information
         Help You To
         Understand



      OZONE
Developments in the Ozone
Technology

Ozone has been used for disinfections
of drinking water in the municipal
water industry in europe for over 100
years and is used by a large number of
water companies, where ozone
generator capacities in excess of 100
kg/h are common.
What is Ozone?
 Ozone is a molecule composed of three atoms of oxygen. Two atoms of
 oxygen form the basic oxygen molecule--the oxygen we breathe that is
 essential to life. The third oxygen atom can detach from the ozone
 molecule, and re-attach to molecules of other substances, thereby altering
 their chemical composition. It is this ability to react with other substances
 that forms the basis of manufacturers claims. Ozone (O3) is one of the
 strongest oxidizing agents that are readily available. It is used to reduce
 color, eliminate organic waste, reduce odor and reduce total organic
 carbon in water. Ozone is created in a number of different ways, including
 ultra violet (UV) light, corona discharge of electricity through an oxygen
 stream (including air), and several others. In treating small quantities of
 waste, the UV ozonators are the most common, while large-scale systems
 use either corona discharge or other bulk ozone-producing methods.
 Ozone is formed as oxygen (O2) is struck by a source of energy. The
 bonds that hold the O2 together are broken and three O2 molecules are
 combined to form two O3 molecules. The ozone begins to break down
 fairly quickly, and as it does so, it reverts back into O2. The bonds that
 hold the Ö atoms together are very weak, which is why ozone acts as a
 strong oxidant as readily as it does.
History of Ozone

1840 - Discovered by Schönbein
1893 - Used as a disinfectant in drinking
            water
1909 - Used as a food preservative for
       cold storage of meats
1939 - Was found to prevent the growth of
       yeast & mold during the storage of
           fruits
Ozone Properties

  Property                       Ozone                 Oxygen
Molecular Formula                   O3                    O2

Molecular Weight:                   48                    32

Color                            Light Blue            Colourless

Smell                 -clothes  after being outside    Odorless
                              on clothesline
                         - photocopy machines
                      - smell after lightning storms
Solubility in Water                0.64                  0.049
(@ O-deg C)
Density (g/l):                     2.144                 1.429

Electrochemical                    2.07                  1.23
Potential, V:
How Ozone works?
Ozone offers real advantages over chlorine bleach and other disinfectants
used in the dialysis field because of its strong oxidizing power that inactivates
pyrogenic lippopolysaccharides (endotoxin) and destroys total organic
carbon (TOC). Additionally, ozone has a higher lethality coefficient than
chlorine and other disinfectants against most organisms and readily destroys
viruses. The action of ozone is through the agency of free radicals produced
by the incorporation of ultraviolet radiation. The covalent bond connecting
two atoms consists of the mutual sharing by these atoms of two bonding
electrons. This valence may break in two ways: In one process, one of the
atoms may acquire both bonding electrons, leaving the other with none. This
type of bond cleavage gives rise to ions. The electron being the seat of
negative electricity, one atom possesses more than its original share of
negatively charged electrons, or an anion. The other atom is deprived of its
normal complement of electrons and becomes positively charged, or a
cation.
The covalent bond may also rupture, leaving each of the constituent atoms with one of

the bonding electrons. These atoms are now free radicals, which require combinations

with other free radicals to form stable molecules. Alternatively, a free radical may form a

linkage with a molecule and abstract an atom and a bonding electron. This action

stabilizes the free radical, but in the process forms a new free radical. A series of free

radical attacks upon molecules results in a free radical chain. Eventually the free radical

chain terminates. Free radicals have half-life durations whose length are inverse

expressions of their stabilities. Thus, the more unstable the free radical, the more avid its

need to bond, the shorter its half-life. Also, the more unstable the free radical, the

broader the spectrum is of molecules it can interact with. Hydrogen abstraction from

carbon atoms, as well as carbon-carbon bond cleavage to create free radical chains can

be initiated by the hydroxyl free radicals caused by the action of the ozone upon water:

O3 + H2O             O2 + 2OH

Hydroxyl free radicals are generated by ozone in water in a several step reaction. Carbon

dioxide is the final product of the oxidative free radical chain.
Ozone Generation
Nearly all commercial ozone generators employ the corona discharge principle.
Properly dried air, or oxygen itself, is passed between a high-voltage electrode
and a ground electrode separated by a dielectric material. Considerable
electrical energy is required for the ozone producing electrical discharge field to
be formed. In excess of 80% of the applied energy is converted to heat that, if
not rapidly removed, causes the ozone to decompose, particularly above 35° C
(95° F). Proper cooling of the ozone generator is crucial to maintaining ozone
yields. Some units include a composite mixing tank that mixes the fluid stream
with ozone via a venturi side-stream. The side-stream venturi injection method
is recognized by some as more efficient than the fine bubble diffuser type for
transferring ozone to water. Electrolytic generation of ozone results in the
formed ozone being rapidly dissolved in water. However, the small quantity of
ozone containing water involved must be dispersed throughout the water being
treated. The use of static mixers, storage tanks and distribution loops serve this
purpose.
Ozone Generators
The power of ozone generators is estimated in two ways ie - the production of

ozone per hour or yield (g/H or grams per hour) and quantity of ozone in weight

per unit of volume of the bearer gas (mg/L) or concentration. EnviroSafe

designs and manufactures OZONE GENERATORs caters to a range from 100

Mg/Hr to 5000 Gm/Hr. A swimming pool of Olympic size would hardly require 20

grams of ozone per hour from high concentration machines, but over 60 grams

from low concentration air fed generators. The reason is that the solubility of

Ozone in water is proportional to the concentration of ozone in the bearer gas.
Oxidizing Potential of Various Reagents

       Oxidizing Reagent       Oxidizing Potential
             Ozone                    2.07
        Hydrogen Peroxide             1.77
          Permanganate                1.67
         Chlorine Dioxide             1.57
        Hypochlorous acid             1.49
          Chlorine Gas                1.36
        Hypobromous acid              1.33
             Oxygen                   1.23
            Bromine                   1.09
         Hypoiodous acid              0.99
          Hypochlorite                0.94
             Chlorite                 0.76
             Iodine                   0.54
Ozone vs Chlorine
The US Government for 8 HOURS installation rates      Chlorine is not only toxic; it is also a poisonous
ozone as toxic at 100PPT level only.                  gas

Ozone is generated on the premises and not            Chlorine is stored in high pressure containers on
stored or transported.                                the premises and is hazardous.
Ozone degrades all organic substances to make         Chlorine, on the other hand, when mixed with
them into harmless ashes and does not leave any       body fluids and perspiration, will form chloramines
other by-products than Oxygen.
      by-                                             that will cause eye irritation and are carcinogenic
                                                      by nature.

Ozone has become less expensive due to an             The cost of chlorine is constantly increasing and it
increase in efficiency and lower energy               has become quite expensive
consumption
Ozone does not require pH control, but some other     Chlorine needs pH control ( 7.0 to 7.4 pH) for
chemicals use may require such control.               reliable results.
-Tests have proven that ozone is 600 to 3000          But to be killed by chlorine Ecoli required 15,000
times more active in the destruction of bacteria      seconds at a concentrations of 1 mg/l
and viruses than Chlorine in the same
concentrations. Ecoli is killed within 5 seconds by
ozone at a concentration of 1 mg/l. Even the cyst
and spores cant resist ozone.

-Ozone is an excellent deodorizing agent for many     Chlorine doesn't have such effect.
substances, such as hydrogen sulfide, ammonia,
smoke, cooking smells, paint, etc. Whereas,
Chlorine is not a deodorizing agent.
-Ozone is effective against decomposition of
wastes, mildew, and fungus and can be used to
eliminate locker room odor in dressing room.
Ozone is the strongest oxidant on the market !
    Ozone vs. Chlorine
                Action in Water                    Chlorine      Ozone

Oxidation Potential (Volts)-
                    (Volts)-                         1.36          2.07

Disinfection:                      Bacteria        Moderate      Excellent
                                    Viruses        Moderate      Excellent

Environmentally Friendly                              No           Yes

Color Removal                                        Good        Excellent

Carcinogen Formation                                Likely       Unlikely

Organics Oxidation                                 Moderate        High

Micro flocculation                                   None        Moderate

pH Effect                                          Variable      Lowers

Water Half-Life
      Half-                                        2-3 hours     20 min.

Operation Hazards:              Skin Toxicity        High        Moderate
                           Inhalation Toxicity       High          High

Complexity                                           Low           High

Capital Cost                                         Low           High

Monthly Use Cost                                 Moderate-High
                                                 Moderate-         Low
Industrial Applications of Ozone
Using ozone in industrial applications does not produce any by-product to contaminate the ecological system further. In
                                                            by-
the conventional methods, there would be by-products created in the process and this creates problems in one way or the
                                         by-
other. However, Ozone leaves only pure oxygen and inert oxides as by-products. There is a vast potential for applications
                                                               as by-
in sewage treatment industry, as there is a lot of opportunities for detoxifying, de-coloring and deodorizing. As OGs were
                                                                                  de-
capital intensive, it is not favourable in these industries and in the midst of recession. The support from the government
such as decreasing taxes, offering other encouragements, higher depreciation or other benefits is lacking.


However, Ozone has more potential applications in other industries such as hospitality industry, fish farms, cooling towers
                                                        industries
beverage manufacturers, and mineral water plants.


One of the important future applications is the replacement of Auto-Claves, an apparatus to sterilize surgical instruments,
                                                               Auto-
being developed for the first time in the world. In the conventional method, surgical instruments were boiled and
                                                        conventional
pressurized in Autoclaves. In addition to being a laborious process, it also consumed a lot of energy. This can be easily
                                                            process,
replaced by ozone-based disinfectors with high concentration of ozone circulating in a stream of water and dipping the
            ozone-
instruments to become sterilized almost instantaneously and using less energy.
                                                            using


Other important niches for Ozone are: the cooling waters, (Keeping the cooling water sparkling without any chemical
                                                          (Keeping
build-up and hence, no need of blow-down and zero-pollution,) fish ponds, (for the same reason) sewage water treatment
build-                         blow-         zero-                                                           treatment
plants and also to remove the stench, and generally a host of applications where the liquid fire of high concentration
                                                              applications
Ozone, will oxidise unwanted molecules which otherwise resist all other treatments, such as the pesticides, DDT, Deldrin,
                                                                                                                 Deldrin,
Arsenic, Aldrin, and other toxic or poisonous substances.
         Aldrin,
More About

OZONE
The Universal Disinfectant
 Disinfection by 3-atomic oxygen called OZONE takes place by rupture of the cell wall - a more
 efficient method than Chlorine that depends upon diffusion into the cell protoplasm and
 inactivation of the enzymes. Ozone level of 0.4 ppm for 4 minutes has been shown to kill any
 bacteria, virus, mold and fungus.


 When the effectiveness of Ozone as a disinfectant was measured, up to a certain dosage there
 was little or no disinfection. At higher levels the sanitizing effect increased greatly. For complete
 disinfection there has to be a surplus of residual Ozone in the solution to assure that every living
 microorganism has been contacted.


 In the area of viruses there is yet to be discovered an antibiotic that is truly effective. There are
 indications that DNA viruses such as Herpes are implicated in human cancers, since they
 organize the genetic material of the host cell to produce new viruses. Ozone will inactivate
 viruses on contact even at very low residual concentrations. In case of polio only 0.012 ppm
 removes all viruses in less than 10 seconds.


 Mold and mildew are easily controlled by Ozone in air and in water. Giardia and
 Cryptosporidium cysts are susceptible to Ozone but not effected by normal levels of Chlorine.
 Mold and mildew are easily controlled by Ozone in air and in water. Giardia and Cryptosporidium
 cysts are susceptible to Ozone but not effected by normal levels of Chlorine.
TASTE & ODOR CONTROL
 Most tastes and odors in water supplies come from naturally

 occurring or manmade organic material contamination.

 Bacterial decomposition of humic material imparts taste to

 surface water, also the action of algae and actinomycetes give

 rise to objectionable tastes. Chlorination of humic material

 leads to chlorophenols that are far stronger odor and taste

 antigonists than the original phenol and the Chlorine. Most of

 these odors are removed by treatment with Ozone. Even some

 sulfur compounds such as hydrogen sulfide, mercaptans or

 organic sulfides can be oxidized to Sulfates with Ozone.
REMOVAL OF HEAVY METALS

Ozone oxidizes the transition metals to their higher oxidation state in

which they usually form less soluble oxides, easy to separate by

filtration. e.g. iron is usually in the ferrous state when it is dissolved in

water. With ozone it yields ferric iron, further oxidized in water to Ferric

Hydroxide that is very insoluble and precipitates out for filtration.

Other metals: Arsenic (in presence of Iron), Cadmium, Chromium,

Cobalt, Copper, Lead, Manganese, Nickel, Zinc - can be treated in a

similar way. At Ozone levels above 4 ppm however, Manganese will

form soluble permanganate, showing up as a pink color.
COLOR REMOVAL
Surface waters are generally colored by natural organic materials

such as humic, fulvic and tannic acids. These compounds result from

the decay of vegetative materials and are generally related to

condensation products of phenol like compounds; they have

conjugated carbon/carbon double bonds. When the series of double

bonds extend upwards of twenty, the color absorption shows up in

the visible spectrum. Ozone is attracted to break organic double

bonds. As more of these double bonds are eliminated, the color

disappears. Surface water can usually be decolorized when treated

with 2 to 4 ppm of Ozone.
OZONE vs. CHLORINE
In comparing disinfection efficiency, Ozone is effective 25 x more than Hypochlorous acid (HOCI),
2,500 x more than Hypochlorite (OCI) and 5,000 x more than Chloramine (NH2CL). This is measured
by comparison of CT constants - the Concentration & Time needed to kill 99.9% of all microorganisms.
Chlorine reacts with organic materials to form Chlorine containing organics such as Chloroform,
Carbon Tetrachloride, Chloromethane and others, generally known as Trihalomethanes (THMs).



Ozone reacts with Organics to break them down into simpler compounds. These (e.g. Oxalic Acid) do
not readily break down all the way to Carbon Dioxide with just Ozone, but if subjected to bacterial
degradation on activated charcoal, they will be removed. This water can be later treated with a low
level of Chlorine say 0.2 - 0.3 ppm to maintain sanitation in the distribution system. This way no THMs
will be formed. The THMs have been implicated as carcinogens in the development of Kidney, Bladder
and Colon Cancer. The regulatory authorities are again decreasing the levels of THMs that can be in
Community water systems. At the present time the limit is 0.05 ppm. Based on the scientific research,
the level will be most likely soon lowered to 0.01 ppm.



Ozone does not react significantly with THMs as they are more resistant to oxidation - it takes a very
long time to achieve full oxidation. Some THMs are removed as a result of physical sparging by the
aeration action of the ozone/air mixture.
ALGAE REMOVAL
Ozonation of a water contaminated with Algae oxidizes and floats
the Algae to the top of the reservoir. The ozone will also oxidize the
metabolic by-products of the Algae and remove the undesirable
odor and taste.

IMPROVED COAGULATION & TURBIDITY
REMOVAL
Oxidation of dissolved organic materials by Ozone results in polar and
charged molecules that can react with Polyvalent Aluminum or Calcium to
form precipitates. Treatment of a surface water with up to 0.5 ppm of
Ozone results in a decrease in turbidity, improved settleability and a
reduction in the number of particles. Referred to as pre-ozonation this
treatment destabilizes the colloid with a resultant reduction of the amount
of coagulant needed to produce a clear filtrate.
OZONE REACTIONS TO ORGANICS
Ozone reacts rapidly with most simple aromatic compounds and unsaturated
aliphatic, such as Vinyl Chloride, 1,1-dichloroethylene, trichloroethylene, p-
dichlorobenzene, Benzene, etc. But it reacts slowly with complex aromatics and
saturated aliphatic. Ozone will degrade many organic compounds, such as
sugars, phenols, alcohols, and as it degrades these materials it returns to
Oxygen.



Coupling Ozone with Hydrogen Peroxide will cause the formation of very
active Hydroxyl ions which cause a nucleophilic attack on organic compounds.
This can cause displacement of Halogens and other functional groups such as
Amines and Sulfides. Coupling Ozone with Hydrogen Peroxide will cause the
formation of very active Hydroxyl ions which cause a nucleophilic attack on
organic compounds. This can cause displacement of Halogens and other
functional groups such as Amines and Sulfides.
OZONE SOLUBILITY
        The solubility of Ozone depends on the temperature of water and concentration of
                                    Ozone in the gas phase.




                   25

                                       22.18
                                                         19.5
                   20
                                                                    16.79

                                   14.79
                    15
                                                                                      12.86
                                                    13
                                                                                                                 O3 Gas
                                                                 11.19
                    10
                            11.9
                                                                                 8.57                                 1.5%
                                            9.75
                        5
                                                           8.4                                                        2.00%
                                                                                                 3.00%
                                                                          6.43                2.00%
                        0                                                                                             3.00%
                            5°C
                                                                                         1.5%
                                           10°C
                                                          15°C
                                                                         20°C


             5°C                             10°C                           15°C                         20°C

            11.9                             9.75                               8.4                      6.43
1.5%
            14.79                             13                            11.19                        8.57
2.00%
            22.18                            19.5                           16.79                        12.86
3.00%
If oxidizable chemicals are present in the water, even more Ozone will
dissolve to satisfy the demand. One limiting factor is the efficient of the
mass transfer device used. In case of a pump and Bubble Diffuser, the
water column should be at least 16ft. high. Higher concentrations of Ozone
in water cause more vigorous oxidation of even resistant organic
compounds.
AIR TREATMENT
Ozone reacts rapidly with most odors, oxidizing them to less harmful elements or all the
way to harmless Carbon Dioxide.



More and more of our furnishings and floor coverings are made from synthetic materials.
Under the stagnant air conditions which prevail because of the lack of ventilation,
decomposition products and solvents leach out of these synthetic materials and fill the
indoor space. Much has been said about the sick building syndrome and this usually
refers to institutional building. But they have basically the same problems as the private
home. When odors are inhaled, they increase the demand for oxygen in the human body
thus depleting the body of oxygen.



Ozone in natural settings is around 0.02 ppm, but it can be as high as 0.10 ppm. At this
level it is capable of keeping pathogens in check and yet at this level ozone is not
harmful to higher life forms such as fish, birds, animals or man. Ozone is not causing
harm to the nature. Only a prolonged exposure to very unnatural high levels of ozone
may lead to discomfort, later headache and coughing, telling you to leave the space and
seek better air.
ENERGY CONSUMPTION IN COMMERCIAL
           BUILDINGS


                        HVAC
40%

                        OTHER UTILITIES
              60%
                        AND LIGHTING
COOLING LOAD BREAK UP FOR HIGH
         OCCUPANCY APPLICATIONS -
      MALL,MULTIPLEX,IT AND SOFTWARE
               OFFICE ETC.
                             FRESH AIR
                  35%
                             COOLING LOAD
                             OTHER COOLING
65%
                             LOAD
WHY DO WE NEED FRESH AIR ?

 TO REDUCE THE VOLATILE ORGANIC
 COMPOUNDS (VOC)
 TO REMOVE ODOURS
 TO DILUTE CO2


IN SHORT FRESH AIR IS REQUIRED TO
 IMPROVE THE INDOOR AIR QUALITY
HOW DOES FRESH AIR IMPROVE
   INDOOR AIR QUALITY ?

  •THE OXYGEN IN THE FRESH AIR
   OXIDISES THE VOC AND ODOURS
  •THE OXYGEN IN THE FRESH AIR
   ALSO DILUTES THE CO2

IN SHORT , OXYGEN IN THE FRESH
      AIR DOES THE WORK
ASHRAE VENTILATION CODE
       NO 62-1999

 •MINIMUM 15 CFM PER PERSON


 •30 CFM PER PERSON IF SMOKING IS
  PERMITTED
ENERGY CONSUMED BY
         FRESH AIR
•150 CFM OF FRESH AIR IN MUMBAI WILL
  REQUIRE 1 TON OF COOLING LOAD
•THIS WILL CONSUME APPROX. 1 KW
 ENERGY FOR A WATERCOOLED
 SYSTEM OR 1.3 KW OF ENERGY FOR
 AN AIRCOOLED SYSTEM
HOW CAN WE MINIMISE THIS
    ENERGY WASTAGE ?
 •AIR QUALITY IMPROVES DRAMATICALLY.
   •OXYGEN IS THUS REQUIRED ONLY TO
DILUTE THE CO2 . THIS IS A MUCH SMALLER
             REQUIREMENT.
  •THUS FRESH AIR CAN BE MODULATED
RATIONALLY DOWN TO 5 CFM OR LESS PER
               PERSON.
HOW CAN WE MINIMISE THIS
  ENERGY WASTAGE ?


 •THIS WILL REDUCE THE
  OVERALL PLANT
  CAPACITY BY UP-TO 25 %
SAVING IN HVAC LOAD DUE TO
                              REDUCED
             OZONIZATION      FRESH AIR
                                COOLING LOAD
                                AFTER
                                OZONIZATION
                10%             SAVING IN
                                LOAD DUE TO
                      25%       OZONIZATION


65%                             OTHER
                                COOLING LOAD
SAVING IN OVERALL ENERGY CONSUMPTION (HIGH
                 OCCUPANCY APPLICATION)



                                      ENERGY CONSUMED
                                      BY LOAD OTHER THAN
                                      HVAC

                                      ENERGY CONSUMED
               15%
      6%                              BY HVAC NON FRESH
                                      AIR LOAD

                                      ENERGY CONSUMED
                            40%
                                      BY REDUCED FRESH
39%
                                      AIR AFTER
                                      OZONIZATION
                                      SAVING IN ENERGY
                                      DUE TO RATIONAL
                                      MODULATION OF
                                      FRESH AIR
PERMISSIBLE OZONE
           CONCENTRATION
If residual concentration exceeds, Ozone is a toxic gas.
maximum Permissible Concentration in Occupied space:

OSHA: 0.1 ppm ( 100 PPB)
            Exposure of 8 Hr /day, 5 days a week

ASHRAE:       0.05 ppm (50 ppb)

FDA:          0.05 ppm ( 50 ppb)
              Continuous exposure 24 hr/day
              365 Days a year
METHODS TO ENSURE
CONCENTRATION WITHIN
       LIMITS

Use Auto VOC Sensor and Controller
Based on the residual VOC
Regulate output of ozone Generator
Use Ozone Monitor to alarm / trip
Ozone Generator in the event of high
concentration
ANNULAR               CORONA                             GENERATOR

                                                             AHU

                            Supply Air Duct                        Return Air Duct



                                                                                                 VOC Sensor




                  Solid State Frequency
                  Converter
                                               Transformer


                                                                                     Ozone Injection Tube to HVAC Duct

                                   Applied Electricity
   Applied Line
                                   to Corona Tube
      Power




                           V, F




                  M
                                                     Annular
                                                   Corona Tube
                       M
                                       V, F
                        Air Flow
                        From Fan



M = MASS FLOW OF AIR OVER CORONA TUBE
V = APPLIED VOLTAGE ACROSS DIELECTRIC
F = APPLIED FREQUENCY ACROSS DIELECTRIC
Ł = QUANTITY OF OZONE PRODUCED
LM
LV
LF
ANNULAR             CORONA              GENERATOR
                                                                        FIG 2
                                                      ANNULAR TUBE
                                                      OZONE GENERATOR




                     AHU

  SUPPLY AIR DUCT                   RETURN AIR DUCT



                                                       VOC SENSOR




                           INDOOR AIR SPACE




                      RESIDUAL OZONE = 03

                      RESIDUAL VOC = V
CONCLUSION
         Benefit of OZONE SYSTEM
                 ACHIEVES

Dramatic reduction in build up of HC,Toxic
  Gases, and VOC
  Dramatic Reduction in Odor
  Near Total Elimination of Cigarette Smoke.
  Depletion of Microbial Colonies (Fungi) in
  Ducts and AHU cooling coils. Eliminates
  duct cleaning
  Depletion of Microbial (Fungi) Indoor
CONCLUSION (CONTD)
     ECONOMIC BENEFITS
   DIRECT ECONOMIC BENFITS OF
         OZONE SYSTEMS

       CAPITAL COST SAVINGS
Reduced size and capacity of HVAC
systems.
Cost of EnviroSafeTM Ozone System is
often lower than Savings in HVAC plant
reduction
  Net Result: REDUCED CAPITAL COST
CONCLUSION (CONTD)
   ENVIRONMENTAL BENEFITS

Reduced Fungi and Microbes in Ducts,
Cooling Coils and Indoor

Reduced Allergy Related Disorders

Cleaner Indoor, Cleaner Ducts
ECONOMIES
 Ozone is effective against a large variety of water treatment problems. In
 general, the more problems in the water to be treated with ozone, the less an
 ozonation system costs when compared to other more conventional treatment
 methods. When one is comparing the cost of an ozonation system to other
 treatment systems there are some key factors to consider; here are a few:

 There is no need to purchase, ship or store chemical oxidants or disinfectants

 There is no labor for handling.

 Many health and safety concerns are reduced or eliminated.

 Because ozone reacts so much more quickly there is opportunity for substantial
 savings in space requirements for the treatment system.

 Because ozone treatment design is flexible, one of the variety of installations
 can be adapted to any fit any design circumstance.

 It is likely that much of your existing treatment facilities are adaptable to an
 ozone based treatment system.

 The pay back of your investment can be surprisingly short.
Venturi Injector
 Venturi Injectors (Injectors) work by forcing water through a conical
 body which initiates a pressure differential between the inlet and
 outlet ports. This creates a vacuum inside the injector body, which
 initiates ozone suction through the suction port.




Characteristics
    •   Very high ozone mass transfer rate (up to 60 to 70%)
    •   Requires water pump to initiate suction
    •   Efficiency rarely decreases over time
    •   No moving parts
Bubble Diffusers
Bubble Diffusers work by emitting ozone through hundreds of bubbles beneath
the waters surface.

                      Characteristics:
                      Low ozone mass transfer rate (typically around 10-15%)
                      Efficiency increases with increased water depth
                      Requires air-pump to transfer oxygen below surface
                      Diffuser holes become fouled decreasing transfer efficiency
What happens inside a static
    mixer?

                                If you think a venturi injector is good enough,

                                think again. Venturi injectors do attain fairly good

                                mass transfer, but using a static mixer can greatly

                                improve your mass transfer efficiency up to 90 to

                                95%.


Notice how the bubbles are made into a fine mist as they move from left to right

resulting in significantly greater ozone mass transfer than using a venturi alone.

Pipe size is 1-1/2 diameter.
Pilot Ozonation for
Drinking Water
Applications:
  Destruction of bacteria and viruses
  Oxidation of iron and manganese
  Heavy metal precipitation
  Colour destruction
  Taste improvement
  Algae and protozoa destruction
  Hardness reduction
  Hydrogen sulphide and mercaptans
  elimination
Ozone chemical free treatments
& applications

Domestic/Municipal
                            Cooling towers treatment
Pulp & paper
                            Boiler water treatment
Mining (Cyanide,Arsenic)
                            Chilled water treatment
Pharmaceutical (Phenol )
                            Cutting fluids recycling
Textile
                            Barn disinfecting (air/water)
Leather
                            Hydroponics
Petroleum/Petrochemicals    Animal waste treatment
Electroplating              Water dripping treatment
Heavy metal precipitation   Animal drinking water
Landfill leacheates         Irrigation water disinfecting
Ozone chemical free treatments
& applications
Drinking & water bottling         Smoke & odour treatment
Food Grain disinfecting           Semiconductor wafers clean
Fruit & vegetable storage         Laundry water recycling
Meat storage                      Med. instrument sterilization
Slaughter house disinfecting      Hospital air sterilization
Fruits & vegetable wash           Aqua-culture
Food containers sterilizations    Paper pulp bleach
Wine/Beer SO2 replacement         Sour gas desulphurization
Chicken egg wash                  Zebra mussels treatment
Ozonated meat grinders            Rubber recycling

             Operation Theater For Disinfection
The measure of an oxidiser and its ability to oxidise organic and inorganic material is its oxidation potential
(measured in volts of electrical energy). Oxidation potential indicates the degree of chemical transformation to
be expected when using various oxidants. It gauges the ease with which a substance loses electrons and is
converted to a higher state of oxidation



Theoretically the substance with the lower oxidation potential will be oxidised by the substance with the higher
oxidation potential. A substance can only be oxidised by an oxidiser with a higher potential. The oxidation
potentials of common oxidants and disinfectants associated with water and wastewater treatment are all of a
lower oxidation potential than ozone. There is only one element with a higher oxidation potential than ozone
and that is fluorine.



Oxidation potential does not indicate the relative speed of oxidation nor how complete the oxidation reactions
will be. Complete oxidation converts a specific organic compound to carbon dioxide and water. Oxidation
reactions that take place during water treatment are rarely complete, due to the large quantity of contaminants
and relatively short durations of time in which to oxidise the water pollutants.



Although the relative position of an oxidant is indicative of its ability to oxidise other materials, it does not
indicate how fast one material will be oxidised by another, nor how far toward completion (to carbon dioxide
and water) the oxidation reaction will proceed.
Post-Ozonation Requirements
    The ozonation treatment step is usually followed by :


    1.       Clarification: to precipitate oxidised organic and inorganic matter.
    2.       Filtration (nano, sand, charcoal): to remove precipitants. The use of activated
             carbon filters has the added advantage of adsorbing the excess unreacted,
             unrecycled ozone and allows it to convert back to oxygen.


             This increased understanding of ozone oxidation has lead to the broadening of
             its applications making it the one of the fastest growing market segments
             within the drinking water and waste water treatment industry. Other industries
             employing ozone treatment include the agricultural, food, pharmaceutical, and
             electronic industries. Lower ozone production costs have allowed this material
             from the past to have modern applications.




Disclaimer: The articles about ozone are collected from several sources from the internet and does not necessarily reflect EnviroSafe applications
and experience
Comparative Analysis of Water Treatment Methods

Criteria               U.V. Radiation   Ozone   Chlorine
ESSENTIAL
Harmful By- Products
        By-                 NO           NO       YES
Enviro. Impact
Enviro.                    LOW          LOW      HIGH
Bacteria Removal           SOME         YES       YES
Virus Removal               NO          YES      SOME
Lead Removal                NO          YES       NO
Manganese Removal           NO          YES      SOME
Iron Removal                NO          YES       YES
Odour Removal               NO          YES       YES
Colour Removal              NO          YES      SOME
DESIRABLE
Op. Cost                   MED          LOW       MED
Capital Cost               MED          HIGH      MED
Maintenance                HIGH         MED       MED
Complexity                 MED          MED       MED
Chemical free Pool water
      treatment with Ozone
Ozone can replace partially or totally Chlorine in the pool. It is many times more effective in getting rid of
bacteria & viruses then Chlorine.


It will maintain a very clean water without the use of the many chemicals used to disinfect, to adjust the PH,
Alkalinity...


By comparison to the Chlorine , Ozone water treatment system for pool is virtually maintenance free. All
what you need is to install Ozonator , add the Ozone fix and enjoy.


No Chlorine EVER!!!!
Imagine your pool and spa with no chlorine.
Yes, imagine yourself sitting in your spa with sparkling clean water, no smell of chlorine irritating your nose.
Your bathing suit is not slowly disintegrating from the chlorine in the water.
Yes, imagine you and your children swimming in a pool filled with sparkling water. Enjoy all the pool fun
with out red burning eyes. The blond swimmers don't get green hair. Your skin is smooth and silky, no rash
or itchiness here.

The first concern of pool owners should be the safety of the water in your pool. OZONE is one of the
strongest oxidizers available. Only fluorine is stronger. Chlorine is a weaker oxidizer. Ozone water
treatment system has a quicker kill time of organisms and kills more types. OZONE is used to purify
Olympic pools. In fact the athletes in the LA Olympics refused to swim in a pool purified by chlorine.

We guarantee NO CHLORINE NEEDED EVER. Instead bromine is used. The bromide combines with the
OZONE to form bromine. The bromine then reacts with the algae. Bromide is then released as a byproduct.
The cycle begins again!! Bromides needs only to be added to replace that removed by water splashing out
of the pool or exiting on the bodies of swimmers.

An added advantage as you can see, is that there are no harmful byproducts. Ozone breaks down into
oxygen. Chlorine on the other hand breaks down into trihalomethanes, which have been shown to increase
the incidence of kidney, bladder and colon cancer. Another byproducts of chlorine plus urine and or
perspiration are chloramines, which cause eye and skin irritation.


                  THOUSANDS THAT TREAT THEIR POOLS THE BEST WAY DOES
            THIS SOUND TOO GOOD TO BE TRUE ??                THIS TIME THE TRUTH IS GOOD
Ozone was first used in swimming pool water treatment in the 1950's. Since then its
use has widely grown. There are over 30,000 swimming pools in Europe that are treated
with ozone. The swimming pools for the Olympics have been treated with Ozone at least
since 1986 for the Los Angeles Olympics. Most recently the Sydney Aquatic Center pool
water was treated with Ozone.
Well known water facilities using ozone to treat their water:



Disneyland and Disney World for all their water features

Mirage Resort, Las Vegas

San Diego Zoo, San Diego, CA for their marine and Aquatic habitats

Vancouver Aquarium, Vancouver, Canada -for their Sea mammal support systems

Universal Studios, Jurassic Park, The Ride“

Many YMCA's and hotels

Waterparks and aquatic centers
WHAT HAPPENS IN YOUR SWIMMING POOL ?

EACH swimmer brings into the pool:
300-400 million bacteria
300-
0.5 gr. of organic matter
30-50 cc of urine
30-

Ozone water treatment system can take care of it!

Ozone kills bacteria, viruses, spores, and mold and does it fast. Ozone pierces the cell wall of bacteria and
                                                            fast.
viruses killing them 3000 times faster than chlorine. Ozone was used to treat the water in the swimming pool
that the AIDS infected blood of Greg Louganis contaminated. No one else contracted AIDS from that incident.
                                                                   one

Ozone water treatment system advantages
       OZONE is produced on site-no storage or transport of dangerous chemicals
                            site-

       OZONE kills all bacteria, viruses, fungi and parasites

       OZONE prevents calcium carbonate scaling and removes existing
                                                            existing

       OZONE not used up slowly decomposes to oxygen up to the saturation point of oxygen in water this

       gives sparkling clean pool water

       OZONE use in the water does not cause discharge liabilities
                                                       liabilities

       OZONE is not affected by pH of water, nor does it affect the pH of water

      OZONE causes increased flocculation of organic wastes, thus increasing the effectiveness of the
                                                             thus

      sand filtration system of your pool.
ARE YOU SURE IT WON'T NEED CHLORINE EVER ?

  YES, we are sure except sometimes for chock treatment in cold climates at the begining of the
season. We use bromides instead of chlorine for residual disinfection and algae destruction. The
bromine reacts with algae and turns to bromide. The bromide recombines with the ozone to reform
    bromine. This starts the cycle over again. Bromide is added in the beginning and additional
       bromide is needed only as water leaves the pool by splashing or on a swimmer's body
                                                            as he/she exits

    There are several models you can choose from depending on the size & usage of your pool.
                                            The following are general guide lines


                                                                       Pool Volume                          O3 G/hr

                                                                       2,000 Liter                          2.5 to 3.0

                                                                       4,000 Liter                          5.0
                                                                       6,000 liter                          8.0
                                                                       10,000 Liter                         15.0
                                                                       20,000 Liter                         25.0


 Disclaimer: The articles about ozone are collected from several sources from the internet and does not necessarily reflect Envirozone
 Technocraft Pvt. Ltd. applications and experience
Ozone FAQ
What is Ozone?

Ozone (O3) is an allotrope of oxygen, the molecule consisting of three oxygen atoms instead of the more
stable diatomic O2
Ozone is a pale blue gas at standard temperature and pressure. It forms a dark blue liquid below -112 ºC
and a dark blue solid below -193 ºC. Ozone is a powerful oxidizing agent. It is also unstable, decaying to
ordinary oxygen through the reaction: 2O3 -> 3O2. This reaction proceeds more rapidly with increasing
temperature and decreasing pressure.

Discovery of ozone

Ozone was discovered by German-Swiss chemist Christian Friedrich Schönbein in 1840, who named it
    after
the Greek word for smell (ozein), from the peculiar odor in lightning storms. (Source: OzoneWikipedia)

Ozone application

Sterilization and purification of water by the use of ozone has been used for may years in drinking water
    and
Waste water treatment plants throughout the world. Ozone is very reactive form of oxygen that can destroy
and enormous variety of liquid waste materials and toxins.

Ozone regulations

In Canada the Worker's Compensation Board of B.C. guidelines stipulate that continuous exposure 8 hours
a day for 5 days per week in an environment containing .08 ppm. of ozone is safe. The output of the
ozonator can be adjusted to be below these limits or others limits depending on the local regulations.
For Sterilization, Disinfection
       & Air Purification
Commercial Ozone Generator
Envirozone Technocraft Pvt Ltd.
  Regd. Office : # 906, Rajhans Tower, Opp. J.K. Tower, Ring Road,
                  SURAT – 395002, Gujarat, INDIA.

      Phone : +91-261-6501355, Fax : +91-261-4002626

                 Website : www.indianozone.com



    Email :   info@indianozone.com   e.safe2007@gmail.com




Thank You for being With Us……..

Contenu connexe

Tendances

UV WATER TREATMENT ( ENG )
UV WATER TREATMENT ( ENG )UV WATER TREATMENT ( ENG )
UV WATER TREATMENT ( ENG )Rony Holoang
 
Purification of water by membrane Technology
Purification of water by membrane TechnologyPurification of water by membrane Technology
Purification of water by membrane TechnologyTahir Nawazkhan
 
WATER & WASTE WATER ENGINEERING - water treatment process & units
WATER & WASTE WATER ENGINEERING -  water treatment process & unitsWATER & WASTE WATER ENGINEERING -  water treatment process & units
WATER & WASTE WATER ENGINEERING - water treatment process & unitsEddy Ankit Gangani
 
Water purification processes in natural systems lecture 2
Water purification processes in natural systems lecture 2Water purification processes in natural systems lecture 2
Water purification processes in natural systems lecture 2Munira Shahbuddin
 
Reverse osmosis for water purification
Reverse osmosis for water purificationReverse osmosis for water purification
Reverse osmosis for water purificationNeslihan Yagmur
 
Waste Water Treatment Process Presentation
Waste Water Treatment Process PresentationWaste Water Treatment Process Presentation
Waste Water Treatment Process PresentationAshish Kakadia
 
Water treatment process
Water treatment processWater treatment process
Water treatment processSonam Pandey
 
Ppt coagulation and flocculation
Ppt coagulation and flocculationPpt coagulation and flocculation
Ppt coagulation and flocculationLokesh Saini
 
Water treatment-lecture-7-eenv
Water treatment-lecture-7-eenvWater treatment-lecture-7-eenv
Water treatment-lecture-7-eenvusman1017
 
Industrial wastewater treatment
Industrial wastewater treatmentIndustrial wastewater treatment
Industrial wastewater treatmentMohamed Ramzy
 
waste water treatment
waste water treatmentwaste water treatment
waste water treatmentAditi122
 
2. screen chamber
 2. screen chamber 2. screen chamber
2. screen chambervvsasane
 
Effluent treatment plant - design, operation and analysis of waste water trea...
Effluent treatment plant - design, operation and analysis of waste water trea...Effluent treatment plant - design, operation and analysis of waste water trea...
Effluent treatment plant - design, operation and analysis of waste water trea...Shubham Hydrosys Pvt. Ltd
 

Tendances (20)

Ozone in package bottled drinking water
Ozone in package bottled drinking waterOzone in package bottled drinking water
Ozone in package bottled drinking water
 
09 chlorination
09 chlorination09 chlorination
09 chlorination
 
UV WATER TREATMENT ( ENG )
UV WATER TREATMENT ( ENG )UV WATER TREATMENT ( ENG )
UV WATER TREATMENT ( ENG )
 
Water purification using micrbes
Water purification using micrbesWater purification using micrbes
Water purification using micrbes
 
Purification of water by membrane Technology
Purification of water by membrane TechnologyPurification of water by membrane Technology
Purification of water by membrane Technology
 
Reverse osmosis
Reverse osmosisReverse osmosis
Reverse osmosis
 
Water purification
Water purificationWater purification
Water purification
 
WATER & WASTE WATER ENGINEERING - water treatment process & units
WATER & WASTE WATER ENGINEERING -  water treatment process & unitsWATER & WASTE WATER ENGINEERING -  water treatment process & units
WATER & WASTE WATER ENGINEERING - water treatment process & units
 
Water purification processes in natural systems lecture 2
Water purification processes in natural systems lecture 2Water purification processes in natural systems lecture 2
Water purification processes in natural systems lecture 2
 
Reverse osmosis for water purification
Reverse osmosis for water purificationReverse osmosis for water purification
Reverse osmosis for water purification
 
ETP.pdf
ETP.pdfETP.pdf
ETP.pdf
 
Waste Water Treatment Process Presentation
Waste Water Treatment Process PresentationWaste Water Treatment Process Presentation
Waste Water Treatment Process Presentation
 
Water treatment process
Water treatment processWater treatment process
Water treatment process
 
Ppt coagulation and flocculation
Ppt coagulation and flocculationPpt coagulation and flocculation
Ppt coagulation and flocculation
 
Membrane technology
Membrane technologyMembrane technology
Membrane technology
 
Water treatment-lecture-7-eenv
Water treatment-lecture-7-eenvWater treatment-lecture-7-eenv
Water treatment-lecture-7-eenv
 
Industrial wastewater treatment
Industrial wastewater treatmentIndustrial wastewater treatment
Industrial wastewater treatment
 
waste water treatment
waste water treatmentwaste water treatment
waste water treatment
 
2. screen chamber
 2. screen chamber 2. screen chamber
2. screen chamber
 
Effluent treatment plant - design, operation and analysis of waste water trea...
Effluent treatment plant - design, operation and analysis of waste water trea...Effluent treatment plant - design, operation and analysis of waste water trea...
Effluent treatment plant - design, operation and analysis of waste water trea...
 

Similaire à Envirozone Ozone Presentation

Similaire à Envirozone Ozone Presentation (20)

Qmax Greentech
Qmax GreentechQmax Greentech
Qmax Greentech
 
What is ozone
What is ozoneWhat is ozone
What is ozone
 
About Ozone - Ozone Engineers
About Ozone - Ozone EngineersAbout Ozone - Ozone Engineers
About Ozone - Ozone Engineers
 
Ozone generator by eltech engineers
Ozone generator by eltech engineersOzone generator by eltech engineers
Ozone generator by eltech engineers
 
SWIMMING POOL DISINFECTION
SWIMMING POOL  DISINFECTIONSWIMMING POOL  DISINFECTION
SWIMMING POOL DISINFECTION
 
Ozone Generation for SWIMMING POOL DISINFECTION
Ozone Generation for SWIMMING POOL DISINFECTIONOzone Generation for SWIMMING POOL DISINFECTION
Ozone Generation for SWIMMING POOL DISINFECTION
 
Atmospheric ozone and its depletion
Atmospheric ozone  and its depletionAtmospheric ozone  and its depletion
Atmospheric ozone and its depletion
 
The ArtiClean Advantage
 The ArtiClean Advantage The ArtiClean Advantage
The ArtiClean Advantage
 
Ozone depletion
Ozone depletionOzone depletion
Ozone depletion
 
10 Chlorine Dioxide Not Chlorine
10 Chlorine Dioxide Not Chlorine10 Chlorine Dioxide Not Chlorine
10 Chlorine Dioxide Not Chlorine
 
OMNI CBW Product Presentation
OMNI CBW Product PresentationOMNI CBW Product Presentation
OMNI CBW Product Presentation
 
What Is Ozone
What Is OzoneWhat Is Ozone
What Is Ozone
 
Ozone in wastewater treatment
Ozone in wastewater treatmentOzone in wastewater treatment
Ozone in wastewater treatment
 
Ozone depletion, Acid Rain, Greenhouse effect and UV Radiation
Ozone depletion, Acid Rain, Greenhouse effect and UV Radiation Ozone depletion, Acid Rain, Greenhouse effect and UV Radiation
Ozone depletion, Acid Rain, Greenhouse effect and UV Radiation
 
Nikhil
NikhilNikhil
Nikhil
 
AP Chemistry Chapter 18 Outline
AP Chemistry Chapter 18 OutlineAP Chemistry Chapter 18 Outline
AP Chemistry Chapter 18 Outline
 
Ozone H2 O2
Ozone H2 O2Ozone H2 O2
Ozone H2 O2
 
Disinfection
DisinfectionDisinfection
Disinfection
 
Ozone Depletion
Ozone DepletionOzone Depletion
Ozone Depletion
 
-bachupally drl
-bachupally drl-bachupally drl
-bachupally drl
 

Dernier

A Call to Action for Generative AI in 2024
A Call to Action for Generative AI in 2024A Call to Action for Generative AI in 2024
A Call to Action for Generative AI in 2024Results
 
[2024]Digital Global Overview Report 2024 Meltwater.pdf
[2024]Digital Global Overview Report 2024 Meltwater.pdf[2024]Digital Global Overview Report 2024 Meltwater.pdf
[2024]Digital Global Overview Report 2024 Meltwater.pdfhans926745
 
Salesforce Community Group Quito, Salesforce 101
Salesforce Community Group Quito, Salesforce 101Salesforce Community Group Quito, Salesforce 101
Salesforce Community Group Quito, Salesforce 101Paola De la Torre
 
08448380779 Call Girls In Civil Lines Women Seeking Men
08448380779 Call Girls In Civil Lines Women Seeking Men08448380779 Call Girls In Civil Lines Women Seeking Men
08448380779 Call Girls In Civil Lines Women Seeking MenDelhi Call girls
 
Understanding the Laravel MVC Architecture
Understanding the Laravel MVC ArchitectureUnderstanding the Laravel MVC Architecture
Understanding the Laravel MVC ArchitecturePixlogix Infotech
 
Mastering MySQL Database Architecture: Deep Dive into MySQL Shell and MySQL R...
Mastering MySQL Database Architecture: Deep Dive into MySQL Shell and MySQL R...Mastering MySQL Database Architecture: Deep Dive into MySQL Shell and MySQL R...
Mastering MySQL Database Architecture: Deep Dive into MySQL Shell and MySQL R...Miguel Araújo
 
From Event to Action: Accelerate Your Decision Making with Real-Time Automation
From Event to Action: Accelerate Your Decision Making with Real-Time AutomationFrom Event to Action: Accelerate Your Decision Making with Real-Time Automation
From Event to Action: Accelerate Your Decision Making with Real-Time AutomationSafe Software
 
Handwritten Text Recognition for manuscripts and early printed texts
Handwritten Text Recognition for manuscripts and early printed textsHandwritten Text Recognition for manuscripts and early printed texts
Handwritten Text Recognition for manuscripts and early printed textsMaria Levchenko
 
IAC 2024 - IA Fast Track to Search Focused AI Solutions
IAC 2024 - IA Fast Track to Search Focused AI SolutionsIAC 2024 - IA Fast Track to Search Focused AI Solutions
IAC 2024 - IA Fast Track to Search Focused AI SolutionsEnterprise Knowledge
 
Transforming Data Streams with Kafka Connect: An Introduction to Single Messa...
Transforming Data Streams with Kafka Connect: An Introduction to Single Messa...Transforming Data Streams with Kafka Connect: An Introduction to Single Messa...
Transforming Data Streams with Kafka Connect: An Introduction to Single Messa...HostedbyConfluent
 
Boost PC performance: How more available memory can improve productivity
Boost PC performance: How more available memory can improve productivityBoost PC performance: How more available memory can improve productivity
Boost PC performance: How more available memory can improve productivityPrincipled Technologies
 
Google AI Hackathon: LLM based Evaluator for RAG
Google AI Hackathon: LLM based Evaluator for RAGGoogle AI Hackathon: LLM based Evaluator for RAG
Google AI Hackathon: LLM based Evaluator for RAGSujit Pal
 
Unblocking The Main Thread Solving ANRs and Frozen Frames
Unblocking The Main Thread Solving ANRs and Frozen FramesUnblocking The Main Thread Solving ANRs and Frozen Frames
Unblocking The Main Thread Solving ANRs and Frozen FramesSinan KOZAK
 
Kalyanpur ) Call Girls in Lucknow Finest Escorts Service 🍸 8923113531 🎰 Avail...
Kalyanpur ) Call Girls in Lucknow Finest Escorts Service 🍸 8923113531 🎰 Avail...Kalyanpur ) Call Girls in Lucknow Finest Escorts Service 🍸 8923113531 🎰 Avail...
Kalyanpur ) Call Girls in Lucknow Finest Escorts Service 🍸 8923113531 🎰 Avail...gurkirankumar98700
 
Injustice - Developers Among Us (SciFiDevCon 2024)
Injustice - Developers Among Us (SciFiDevCon 2024)Injustice - Developers Among Us (SciFiDevCon 2024)
Injustice - Developers Among Us (SciFiDevCon 2024)Allon Mureinik
 
The Role of Taxonomy and Ontology in Semantic Layers - Heather Hedden.pdf
The Role of Taxonomy and Ontology in Semantic Layers - Heather Hedden.pdfThe Role of Taxonomy and Ontology in Semantic Layers - Heather Hedden.pdf
The Role of Taxonomy and Ontology in Semantic Layers - Heather Hedden.pdfEnterprise Knowledge
 
Swan(sea) Song – personal research during my six years at Swansea ... and bey...
Swan(sea) Song – personal research during my six years at Swansea ... and bey...Swan(sea) Song – personal research during my six years at Swansea ... and bey...
Swan(sea) Song – personal research during my six years at Swansea ... and bey...Alan Dix
 
08448380779 Call Girls In Friends Colony Women Seeking Men
08448380779 Call Girls In Friends Colony Women Seeking Men08448380779 Call Girls In Friends Colony Women Seeking Men
08448380779 Call Girls In Friends Colony Women Seeking MenDelhi Call girls
 
FULL ENJOY 🔝 8264348440 🔝 Call Girls in Diplomatic Enclave | Delhi
FULL ENJOY 🔝 8264348440 🔝 Call Girls in Diplomatic Enclave | DelhiFULL ENJOY 🔝 8264348440 🔝 Call Girls in Diplomatic Enclave | Delhi
FULL ENJOY 🔝 8264348440 🔝 Call Girls in Diplomatic Enclave | Delhisoniya singh
 
Slack Application Development 101 Slides
Slack Application Development 101 SlidesSlack Application Development 101 Slides
Slack Application Development 101 Slidespraypatel2
 

Dernier (20)

A Call to Action for Generative AI in 2024
A Call to Action for Generative AI in 2024A Call to Action for Generative AI in 2024
A Call to Action for Generative AI in 2024
 
[2024]Digital Global Overview Report 2024 Meltwater.pdf
[2024]Digital Global Overview Report 2024 Meltwater.pdf[2024]Digital Global Overview Report 2024 Meltwater.pdf
[2024]Digital Global Overview Report 2024 Meltwater.pdf
 
Salesforce Community Group Quito, Salesforce 101
Salesforce Community Group Quito, Salesforce 101Salesforce Community Group Quito, Salesforce 101
Salesforce Community Group Quito, Salesforce 101
 
08448380779 Call Girls In Civil Lines Women Seeking Men
08448380779 Call Girls In Civil Lines Women Seeking Men08448380779 Call Girls In Civil Lines Women Seeking Men
08448380779 Call Girls In Civil Lines Women Seeking Men
 
Understanding the Laravel MVC Architecture
Understanding the Laravel MVC ArchitectureUnderstanding the Laravel MVC Architecture
Understanding the Laravel MVC Architecture
 
Mastering MySQL Database Architecture: Deep Dive into MySQL Shell and MySQL R...
Mastering MySQL Database Architecture: Deep Dive into MySQL Shell and MySQL R...Mastering MySQL Database Architecture: Deep Dive into MySQL Shell and MySQL R...
Mastering MySQL Database Architecture: Deep Dive into MySQL Shell and MySQL R...
 
From Event to Action: Accelerate Your Decision Making with Real-Time Automation
From Event to Action: Accelerate Your Decision Making with Real-Time AutomationFrom Event to Action: Accelerate Your Decision Making with Real-Time Automation
From Event to Action: Accelerate Your Decision Making with Real-Time Automation
 
Handwritten Text Recognition for manuscripts and early printed texts
Handwritten Text Recognition for manuscripts and early printed textsHandwritten Text Recognition for manuscripts and early printed texts
Handwritten Text Recognition for manuscripts and early printed texts
 
IAC 2024 - IA Fast Track to Search Focused AI Solutions
IAC 2024 - IA Fast Track to Search Focused AI SolutionsIAC 2024 - IA Fast Track to Search Focused AI Solutions
IAC 2024 - IA Fast Track to Search Focused AI Solutions
 
Transforming Data Streams with Kafka Connect: An Introduction to Single Messa...
Transforming Data Streams with Kafka Connect: An Introduction to Single Messa...Transforming Data Streams with Kafka Connect: An Introduction to Single Messa...
Transforming Data Streams with Kafka Connect: An Introduction to Single Messa...
 
Boost PC performance: How more available memory can improve productivity
Boost PC performance: How more available memory can improve productivityBoost PC performance: How more available memory can improve productivity
Boost PC performance: How more available memory can improve productivity
 
Google AI Hackathon: LLM based Evaluator for RAG
Google AI Hackathon: LLM based Evaluator for RAGGoogle AI Hackathon: LLM based Evaluator for RAG
Google AI Hackathon: LLM based Evaluator for RAG
 
Unblocking The Main Thread Solving ANRs and Frozen Frames
Unblocking The Main Thread Solving ANRs and Frozen FramesUnblocking The Main Thread Solving ANRs and Frozen Frames
Unblocking The Main Thread Solving ANRs and Frozen Frames
 
Kalyanpur ) Call Girls in Lucknow Finest Escorts Service 🍸 8923113531 🎰 Avail...
Kalyanpur ) Call Girls in Lucknow Finest Escorts Service 🍸 8923113531 🎰 Avail...Kalyanpur ) Call Girls in Lucknow Finest Escorts Service 🍸 8923113531 🎰 Avail...
Kalyanpur ) Call Girls in Lucknow Finest Escorts Service 🍸 8923113531 🎰 Avail...
 
Injustice - Developers Among Us (SciFiDevCon 2024)
Injustice - Developers Among Us (SciFiDevCon 2024)Injustice - Developers Among Us (SciFiDevCon 2024)
Injustice - Developers Among Us (SciFiDevCon 2024)
 
The Role of Taxonomy and Ontology in Semantic Layers - Heather Hedden.pdf
The Role of Taxonomy and Ontology in Semantic Layers - Heather Hedden.pdfThe Role of Taxonomy and Ontology in Semantic Layers - Heather Hedden.pdf
The Role of Taxonomy and Ontology in Semantic Layers - Heather Hedden.pdf
 
Swan(sea) Song – personal research during my six years at Swansea ... and bey...
Swan(sea) Song – personal research during my six years at Swansea ... and bey...Swan(sea) Song – personal research during my six years at Swansea ... and bey...
Swan(sea) Song – personal research during my six years at Swansea ... and bey...
 
08448380779 Call Girls In Friends Colony Women Seeking Men
08448380779 Call Girls In Friends Colony Women Seeking Men08448380779 Call Girls In Friends Colony Women Seeking Men
08448380779 Call Girls In Friends Colony Women Seeking Men
 
FULL ENJOY 🔝 8264348440 🔝 Call Girls in Diplomatic Enclave | Delhi
FULL ENJOY 🔝 8264348440 🔝 Call Girls in Diplomatic Enclave | DelhiFULL ENJOY 🔝 8264348440 🔝 Call Girls in Diplomatic Enclave | Delhi
FULL ENJOY 🔝 8264348440 🔝 Call Girls in Diplomatic Enclave | Delhi
 
Slack Application Development 101 Slides
Slack Application Development 101 SlidesSlack Application Development 101 Slides
Slack Application Development 101 Slides
 

Envirozone Ozone Presentation

  • 1. Envirozone Technocraft Pvt. Ltd Presents Useful Information Help You To Understand OZONE
  • 2. Developments in the Ozone Technology Ozone has been used for disinfections of drinking water in the municipal water industry in europe for over 100 years and is used by a large number of water companies, where ozone generator capacities in excess of 100 kg/h are common.
  • 3. What is Ozone? Ozone is a molecule composed of three atoms of oxygen. Two atoms of oxygen form the basic oxygen molecule--the oxygen we breathe that is essential to life. The third oxygen atom can detach from the ozone molecule, and re-attach to molecules of other substances, thereby altering their chemical composition. It is this ability to react with other substances that forms the basis of manufacturers claims. Ozone (O3) is one of the strongest oxidizing agents that are readily available. It is used to reduce color, eliminate organic waste, reduce odor and reduce total organic carbon in water. Ozone is created in a number of different ways, including ultra violet (UV) light, corona discharge of electricity through an oxygen stream (including air), and several others. In treating small quantities of waste, the UV ozonators are the most common, while large-scale systems use either corona discharge or other bulk ozone-producing methods. Ozone is formed as oxygen (O2) is struck by a source of energy. The bonds that hold the O2 together are broken and three O2 molecules are combined to form two O3 molecules. The ozone begins to break down fairly quickly, and as it does so, it reverts back into O2. The bonds that hold the Ö atoms together are very weak, which is why ozone acts as a strong oxidant as readily as it does.
  • 4. History of Ozone 1840 - Discovered by Schönbein 1893 - Used as a disinfectant in drinking water 1909 - Used as a food preservative for cold storage of meats 1939 - Was found to prevent the growth of yeast & mold during the storage of fruits
  • 5. Ozone Properties Property Ozone Oxygen Molecular Formula O3 O2 Molecular Weight: 48 32 Color Light Blue Colourless Smell -clothes after being outside Odorless on clothesline - photocopy machines - smell after lightning storms Solubility in Water 0.64 0.049 (@ O-deg C) Density (g/l): 2.144 1.429 Electrochemical 2.07 1.23 Potential, V:
  • 6. How Ozone works? Ozone offers real advantages over chlorine bleach and other disinfectants used in the dialysis field because of its strong oxidizing power that inactivates pyrogenic lippopolysaccharides (endotoxin) and destroys total organic carbon (TOC). Additionally, ozone has a higher lethality coefficient than chlorine and other disinfectants against most organisms and readily destroys viruses. The action of ozone is through the agency of free radicals produced by the incorporation of ultraviolet radiation. The covalent bond connecting two atoms consists of the mutual sharing by these atoms of two bonding electrons. This valence may break in two ways: In one process, one of the atoms may acquire both bonding electrons, leaving the other with none. This type of bond cleavage gives rise to ions. The electron being the seat of negative electricity, one atom possesses more than its original share of negatively charged electrons, or an anion. The other atom is deprived of its normal complement of electrons and becomes positively charged, or a cation.
  • 7. The covalent bond may also rupture, leaving each of the constituent atoms with one of the bonding electrons. These atoms are now free radicals, which require combinations with other free radicals to form stable molecules. Alternatively, a free radical may form a linkage with a molecule and abstract an atom and a bonding electron. This action stabilizes the free radical, but in the process forms a new free radical. A series of free radical attacks upon molecules results in a free radical chain. Eventually the free radical chain terminates. Free radicals have half-life durations whose length are inverse expressions of their stabilities. Thus, the more unstable the free radical, the more avid its need to bond, the shorter its half-life. Also, the more unstable the free radical, the broader the spectrum is of molecules it can interact with. Hydrogen abstraction from carbon atoms, as well as carbon-carbon bond cleavage to create free radical chains can be initiated by the hydroxyl free radicals caused by the action of the ozone upon water: O3 + H2O O2 + 2OH Hydroxyl free radicals are generated by ozone in water in a several step reaction. Carbon dioxide is the final product of the oxidative free radical chain.
  • 8. Ozone Generation Nearly all commercial ozone generators employ the corona discharge principle. Properly dried air, or oxygen itself, is passed between a high-voltage electrode and a ground electrode separated by a dielectric material. Considerable electrical energy is required for the ozone producing electrical discharge field to be formed. In excess of 80% of the applied energy is converted to heat that, if not rapidly removed, causes the ozone to decompose, particularly above 35° C (95° F). Proper cooling of the ozone generator is crucial to maintaining ozone yields. Some units include a composite mixing tank that mixes the fluid stream with ozone via a venturi side-stream. The side-stream venturi injection method is recognized by some as more efficient than the fine bubble diffuser type for transferring ozone to water. Electrolytic generation of ozone results in the formed ozone being rapidly dissolved in water. However, the small quantity of ozone containing water involved must be dispersed throughout the water being treated. The use of static mixers, storage tanks and distribution loops serve this purpose.
  • 9. Ozone Generators The power of ozone generators is estimated in two ways ie - the production of ozone per hour or yield (g/H or grams per hour) and quantity of ozone in weight per unit of volume of the bearer gas (mg/L) or concentration. EnviroSafe designs and manufactures OZONE GENERATORs caters to a range from 100 Mg/Hr to 5000 Gm/Hr. A swimming pool of Olympic size would hardly require 20 grams of ozone per hour from high concentration machines, but over 60 grams from low concentration air fed generators. The reason is that the solubility of Ozone in water is proportional to the concentration of ozone in the bearer gas.
  • 10. Oxidizing Potential of Various Reagents Oxidizing Reagent Oxidizing Potential Ozone 2.07 Hydrogen Peroxide 1.77 Permanganate 1.67 Chlorine Dioxide 1.57 Hypochlorous acid 1.49 Chlorine Gas 1.36 Hypobromous acid 1.33 Oxygen 1.23 Bromine 1.09 Hypoiodous acid 0.99 Hypochlorite 0.94 Chlorite 0.76 Iodine 0.54
  • 11. Ozone vs Chlorine The US Government for 8 HOURS installation rates Chlorine is not only toxic; it is also a poisonous ozone as toxic at 100PPT level only. gas Ozone is generated on the premises and not Chlorine is stored in high pressure containers on stored or transported. the premises and is hazardous. Ozone degrades all organic substances to make Chlorine, on the other hand, when mixed with them into harmless ashes and does not leave any body fluids and perspiration, will form chloramines other by-products than Oxygen. by- that will cause eye irritation and are carcinogenic by nature. Ozone has become less expensive due to an The cost of chlorine is constantly increasing and it increase in efficiency and lower energy has become quite expensive consumption Ozone does not require pH control, but some other Chlorine needs pH control ( 7.0 to 7.4 pH) for chemicals use may require such control. reliable results. -Tests have proven that ozone is 600 to 3000 But to be killed by chlorine Ecoli required 15,000 times more active in the destruction of bacteria seconds at a concentrations of 1 mg/l and viruses than Chlorine in the same concentrations. Ecoli is killed within 5 seconds by ozone at a concentration of 1 mg/l. Even the cyst and spores cant resist ozone. -Ozone is an excellent deodorizing agent for many Chlorine doesn't have such effect. substances, such as hydrogen sulfide, ammonia, smoke, cooking smells, paint, etc. Whereas, Chlorine is not a deodorizing agent. -Ozone is effective against decomposition of wastes, mildew, and fungus and can be used to eliminate locker room odor in dressing room.
  • 12. Ozone is the strongest oxidant on the market ! Ozone vs. Chlorine Action in Water Chlorine Ozone Oxidation Potential (Volts)- (Volts)- 1.36 2.07 Disinfection: Bacteria Moderate Excellent Viruses Moderate Excellent Environmentally Friendly No Yes Color Removal Good Excellent Carcinogen Formation Likely Unlikely Organics Oxidation Moderate High Micro flocculation None Moderate pH Effect Variable Lowers Water Half-Life Half- 2-3 hours 20 min. Operation Hazards: Skin Toxicity High Moderate Inhalation Toxicity High High Complexity Low High Capital Cost Low High Monthly Use Cost Moderate-High Moderate- Low
  • 13. Industrial Applications of Ozone Using ozone in industrial applications does not produce any by-product to contaminate the ecological system further. In by- the conventional methods, there would be by-products created in the process and this creates problems in one way or the by- other. However, Ozone leaves only pure oxygen and inert oxides as by-products. There is a vast potential for applications as by- in sewage treatment industry, as there is a lot of opportunities for detoxifying, de-coloring and deodorizing. As OGs were de- capital intensive, it is not favourable in these industries and in the midst of recession. The support from the government such as decreasing taxes, offering other encouragements, higher depreciation or other benefits is lacking. However, Ozone has more potential applications in other industries such as hospitality industry, fish farms, cooling towers industries beverage manufacturers, and mineral water plants. One of the important future applications is the replacement of Auto-Claves, an apparatus to sterilize surgical instruments, Auto- being developed for the first time in the world. In the conventional method, surgical instruments were boiled and conventional pressurized in Autoclaves. In addition to being a laborious process, it also consumed a lot of energy. This can be easily process, replaced by ozone-based disinfectors with high concentration of ozone circulating in a stream of water and dipping the ozone- instruments to become sterilized almost instantaneously and using less energy. using Other important niches for Ozone are: the cooling waters, (Keeping the cooling water sparkling without any chemical (Keeping build-up and hence, no need of blow-down and zero-pollution,) fish ponds, (for the same reason) sewage water treatment build- blow- zero- treatment plants and also to remove the stench, and generally a host of applications where the liquid fire of high concentration applications Ozone, will oxidise unwanted molecules which otherwise resist all other treatments, such as the pesticides, DDT, Deldrin, Deldrin, Arsenic, Aldrin, and other toxic or poisonous substances. Aldrin,
  • 15. The Universal Disinfectant Disinfection by 3-atomic oxygen called OZONE takes place by rupture of the cell wall - a more efficient method than Chlorine that depends upon diffusion into the cell protoplasm and inactivation of the enzymes. Ozone level of 0.4 ppm for 4 minutes has been shown to kill any bacteria, virus, mold and fungus. When the effectiveness of Ozone as a disinfectant was measured, up to a certain dosage there was little or no disinfection. At higher levels the sanitizing effect increased greatly. For complete disinfection there has to be a surplus of residual Ozone in the solution to assure that every living microorganism has been contacted. In the area of viruses there is yet to be discovered an antibiotic that is truly effective. There are indications that DNA viruses such as Herpes are implicated in human cancers, since they organize the genetic material of the host cell to produce new viruses. Ozone will inactivate viruses on contact even at very low residual concentrations. In case of polio only 0.012 ppm removes all viruses in less than 10 seconds. Mold and mildew are easily controlled by Ozone in air and in water. Giardia and Cryptosporidium cysts are susceptible to Ozone but not effected by normal levels of Chlorine. Mold and mildew are easily controlled by Ozone in air and in water. Giardia and Cryptosporidium cysts are susceptible to Ozone but not effected by normal levels of Chlorine.
  • 16. TASTE & ODOR CONTROL Most tastes and odors in water supplies come from naturally occurring or manmade organic material contamination. Bacterial decomposition of humic material imparts taste to surface water, also the action of algae and actinomycetes give rise to objectionable tastes. Chlorination of humic material leads to chlorophenols that are far stronger odor and taste antigonists than the original phenol and the Chlorine. Most of these odors are removed by treatment with Ozone. Even some sulfur compounds such as hydrogen sulfide, mercaptans or organic sulfides can be oxidized to Sulfates with Ozone.
  • 17. REMOVAL OF HEAVY METALS Ozone oxidizes the transition metals to their higher oxidation state in which they usually form less soluble oxides, easy to separate by filtration. e.g. iron is usually in the ferrous state when it is dissolved in water. With ozone it yields ferric iron, further oxidized in water to Ferric Hydroxide that is very insoluble and precipitates out for filtration. Other metals: Arsenic (in presence of Iron), Cadmium, Chromium, Cobalt, Copper, Lead, Manganese, Nickel, Zinc - can be treated in a similar way. At Ozone levels above 4 ppm however, Manganese will form soluble permanganate, showing up as a pink color.
  • 18. COLOR REMOVAL Surface waters are generally colored by natural organic materials such as humic, fulvic and tannic acids. These compounds result from the decay of vegetative materials and are generally related to condensation products of phenol like compounds; they have conjugated carbon/carbon double bonds. When the series of double bonds extend upwards of twenty, the color absorption shows up in the visible spectrum. Ozone is attracted to break organic double bonds. As more of these double bonds are eliminated, the color disappears. Surface water can usually be decolorized when treated with 2 to 4 ppm of Ozone.
  • 19. OZONE vs. CHLORINE In comparing disinfection efficiency, Ozone is effective 25 x more than Hypochlorous acid (HOCI), 2,500 x more than Hypochlorite (OCI) and 5,000 x more than Chloramine (NH2CL). This is measured by comparison of CT constants - the Concentration & Time needed to kill 99.9% of all microorganisms. Chlorine reacts with organic materials to form Chlorine containing organics such as Chloroform, Carbon Tetrachloride, Chloromethane and others, generally known as Trihalomethanes (THMs). Ozone reacts with Organics to break them down into simpler compounds. These (e.g. Oxalic Acid) do not readily break down all the way to Carbon Dioxide with just Ozone, but if subjected to bacterial degradation on activated charcoal, they will be removed. This water can be later treated with a low level of Chlorine say 0.2 - 0.3 ppm to maintain sanitation in the distribution system. This way no THMs will be formed. The THMs have been implicated as carcinogens in the development of Kidney, Bladder and Colon Cancer. The regulatory authorities are again decreasing the levels of THMs that can be in Community water systems. At the present time the limit is 0.05 ppm. Based on the scientific research, the level will be most likely soon lowered to 0.01 ppm. Ozone does not react significantly with THMs as they are more resistant to oxidation - it takes a very long time to achieve full oxidation. Some THMs are removed as a result of physical sparging by the aeration action of the ozone/air mixture.
  • 20. ALGAE REMOVAL Ozonation of a water contaminated with Algae oxidizes and floats the Algae to the top of the reservoir. The ozone will also oxidize the metabolic by-products of the Algae and remove the undesirable odor and taste. IMPROVED COAGULATION & TURBIDITY REMOVAL Oxidation of dissolved organic materials by Ozone results in polar and charged molecules that can react with Polyvalent Aluminum or Calcium to form precipitates. Treatment of a surface water with up to 0.5 ppm of Ozone results in a decrease in turbidity, improved settleability and a reduction in the number of particles. Referred to as pre-ozonation this treatment destabilizes the colloid with a resultant reduction of the amount of coagulant needed to produce a clear filtrate.
  • 21. OZONE REACTIONS TO ORGANICS Ozone reacts rapidly with most simple aromatic compounds and unsaturated aliphatic, such as Vinyl Chloride, 1,1-dichloroethylene, trichloroethylene, p- dichlorobenzene, Benzene, etc. But it reacts slowly with complex aromatics and saturated aliphatic. Ozone will degrade many organic compounds, such as sugars, phenols, alcohols, and as it degrades these materials it returns to Oxygen. Coupling Ozone with Hydrogen Peroxide will cause the formation of very active Hydroxyl ions which cause a nucleophilic attack on organic compounds. This can cause displacement of Halogens and other functional groups such as Amines and Sulfides. Coupling Ozone with Hydrogen Peroxide will cause the formation of very active Hydroxyl ions which cause a nucleophilic attack on organic compounds. This can cause displacement of Halogens and other functional groups such as Amines and Sulfides.
  • 22. OZONE SOLUBILITY The solubility of Ozone depends on the temperature of water and concentration of Ozone in the gas phase. 25 22.18 19.5 20 16.79 14.79 15 12.86 13 O3 Gas 11.19 10 11.9 8.57 1.5% 9.75 5 8.4 2.00% 3.00% 6.43 2.00% 0 3.00% 5°C 1.5% 10°C 15°C 20°C 5°C 10°C 15°C 20°C 11.9 9.75 8.4 6.43 1.5% 14.79 13 11.19 8.57 2.00% 22.18 19.5 16.79 12.86 3.00%
  • 23. If oxidizable chemicals are present in the water, even more Ozone will dissolve to satisfy the demand. One limiting factor is the efficient of the mass transfer device used. In case of a pump and Bubble Diffuser, the water column should be at least 16ft. high. Higher concentrations of Ozone in water cause more vigorous oxidation of even resistant organic compounds.
  • 24. AIR TREATMENT Ozone reacts rapidly with most odors, oxidizing them to less harmful elements or all the way to harmless Carbon Dioxide. More and more of our furnishings and floor coverings are made from synthetic materials. Under the stagnant air conditions which prevail because of the lack of ventilation, decomposition products and solvents leach out of these synthetic materials and fill the indoor space. Much has been said about the sick building syndrome and this usually refers to institutional building. But they have basically the same problems as the private home. When odors are inhaled, they increase the demand for oxygen in the human body thus depleting the body of oxygen. Ozone in natural settings is around 0.02 ppm, but it can be as high as 0.10 ppm. At this level it is capable of keeping pathogens in check and yet at this level ozone is not harmful to higher life forms such as fish, birds, animals or man. Ozone is not causing harm to the nature. Only a prolonged exposure to very unnatural high levels of ozone may lead to discomfort, later headache and coughing, telling you to leave the space and seek better air.
  • 25. ENERGY CONSUMPTION IN COMMERCIAL BUILDINGS HVAC 40% OTHER UTILITIES 60% AND LIGHTING
  • 26. COOLING LOAD BREAK UP FOR HIGH OCCUPANCY APPLICATIONS - MALL,MULTIPLEX,IT AND SOFTWARE OFFICE ETC. FRESH AIR 35% COOLING LOAD OTHER COOLING 65% LOAD
  • 27. WHY DO WE NEED FRESH AIR ? TO REDUCE THE VOLATILE ORGANIC COMPOUNDS (VOC) TO REMOVE ODOURS TO DILUTE CO2 IN SHORT FRESH AIR IS REQUIRED TO IMPROVE THE INDOOR AIR QUALITY
  • 28. HOW DOES FRESH AIR IMPROVE INDOOR AIR QUALITY ? •THE OXYGEN IN THE FRESH AIR OXIDISES THE VOC AND ODOURS •THE OXYGEN IN THE FRESH AIR ALSO DILUTES THE CO2 IN SHORT , OXYGEN IN THE FRESH AIR DOES THE WORK
  • 29. ASHRAE VENTILATION CODE NO 62-1999 •MINIMUM 15 CFM PER PERSON •30 CFM PER PERSON IF SMOKING IS PERMITTED
  • 30. ENERGY CONSUMED BY FRESH AIR •150 CFM OF FRESH AIR IN MUMBAI WILL REQUIRE 1 TON OF COOLING LOAD •THIS WILL CONSUME APPROX. 1 KW ENERGY FOR A WATERCOOLED SYSTEM OR 1.3 KW OF ENERGY FOR AN AIRCOOLED SYSTEM
  • 31. HOW CAN WE MINIMISE THIS ENERGY WASTAGE ? •AIR QUALITY IMPROVES DRAMATICALLY. •OXYGEN IS THUS REQUIRED ONLY TO DILUTE THE CO2 . THIS IS A MUCH SMALLER REQUIREMENT. •THUS FRESH AIR CAN BE MODULATED RATIONALLY DOWN TO 5 CFM OR LESS PER PERSON.
  • 32. HOW CAN WE MINIMISE THIS ENERGY WASTAGE ? •THIS WILL REDUCE THE OVERALL PLANT CAPACITY BY UP-TO 25 %
  • 33. SAVING IN HVAC LOAD DUE TO REDUCED OZONIZATION FRESH AIR COOLING LOAD AFTER OZONIZATION 10% SAVING IN LOAD DUE TO 25% OZONIZATION 65% OTHER COOLING LOAD
  • 34. SAVING IN OVERALL ENERGY CONSUMPTION (HIGH OCCUPANCY APPLICATION) ENERGY CONSUMED BY LOAD OTHER THAN HVAC ENERGY CONSUMED 15% 6% BY HVAC NON FRESH AIR LOAD ENERGY CONSUMED 40% BY REDUCED FRESH 39% AIR AFTER OZONIZATION SAVING IN ENERGY DUE TO RATIONAL MODULATION OF FRESH AIR
  • 35. PERMISSIBLE OZONE CONCENTRATION If residual concentration exceeds, Ozone is a toxic gas. maximum Permissible Concentration in Occupied space: OSHA: 0.1 ppm ( 100 PPB) Exposure of 8 Hr /day, 5 days a week ASHRAE: 0.05 ppm (50 ppb) FDA: 0.05 ppm ( 50 ppb) Continuous exposure 24 hr/day 365 Days a year
  • 36. METHODS TO ENSURE CONCENTRATION WITHIN LIMITS Use Auto VOC Sensor and Controller Based on the residual VOC Regulate output of ozone Generator Use Ozone Monitor to alarm / trip Ozone Generator in the event of high concentration
  • 37. ANNULAR CORONA GENERATOR AHU Supply Air Duct Return Air Duct VOC Sensor Solid State Frequency Converter Transformer Ozone Injection Tube to HVAC Duct Applied Electricity Applied Line to Corona Tube Power V, F M Annular Corona Tube M V, F Air Flow From Fan M = MASS FLOW OF AIR OVER CORONA TUBE V = APPLIED VOLTAGE ACROSS DIELECTRIC F = APPLIED FREQUENCY ACROSS DIELECTRIC Ł = QUANTITY OF OZONE PRODUCED LM LV LF
  • 38. ANNULAR CORONA GENERATOR FIG 2 ANNULAR TUBE OZONE GENERATOR AHU SUPPLY AIR DUCT RETURN AIR DUCT VOC SENSOR INDOOR AIR SPACE RESIDUAL OZONE = 03 RESIDUAL VOC = V
  • 39. CONCLUSION Benefit of OZONE SYSTEM ACHIEVES Dramatic reduction in build up of HC,Toxic Gases, and VOC Dramatic Reduction in Odor Near Total Elimination of Cigarette Smoke. Depletion of Microbial Colonies (Fungi) in Ducts and AHU cooling coils. Eliminates duct cleaning Depletion of Microbial (Fungi) Indoor
  • 40. CONCLUSION (CONTD) ECONOMIC BENEFITS DIRECT ECONOMIC BENFITS OF OZONE SYSTEMS CAPITAL COST SAVINGS Reduced size and capacity of HVAC systems. Cost of EnviroSafeTM Ozone System is often lower than Savings in HVAC plant reduction Net Result: REDUCED CAPITAL COST
  • 41. CONCLUSION (CONTD) ENVIRONMENTAL BENEFITS Reduced Fungi and Microbes in Ducts, Cooling Coils and Indoor Reduced Allergy Related Disorders Cleaner Indoor, Cleaner Ducts
  • 42. ECONOMIES Ozone is effective against a large variety of water treatment problems. In general, the more problems in the water to be treated with ozone, the less an ozonation system costs when compared to other more conventional treatment methods. When one is comparing the cost of an ozonation system to other treatment systems there are some key factors to consider; here are a few: There is no need to purchase, ship or store chemical oxidants or disinfectants There is no labor for handling. Many health and safety concerns are reduced or eliminated. Because ozone reacts so much more quickly there is opportunity for substantial savings in space requirements for the treatment system. Because ozone treatment design is flexible, one of the variety of installations can be adapted to any fit any design circumstance. It is likely that much of your existing treatment facilities are adaptable to an ozone based treatment system. The pay back of your investment can be surprisingly short.
  • 43. Venturi Injector Venturi Injectors (Injectors) work by forcing water through a conical body which initiates a pressure differential between the inlet and outlet ports. This creates a vacuum inside the injector body, which initiates ozone suction through the suction port. Characteristics • Very high ozone mass transfer rate (up to 60 to 70%) • Requires water pump to initiate suction • Efficiency rarely decreases over time • No moving parts
  • 44. Bubble Diffusers Bubble Diffusers work by emitting ozone through hundreds of bubbles beneath the waters surface. Characteristics: Low ozone mass transfer rate (typically around 10-15%) Efficiency increases with increased water depth Requires air-pump to transfer oxygen below surface Diffuser holes become fouled decreasing transfer efficiency
  • 45. What happens inside a static mixer? If you think a venturi injector is good enough, think again. Venturi injectors do attain fairly good mass transfer, but using a static mixer can greatly improve your mass transfer efficiency up to 90 to 95%. Notice how the bubbles are made into a fine mist as they move from left to right resulting in significantly greater ozone mass transfer than using a venturi alone. Pipe size is 1-1/2 diameter.
  • 46. Pilot Ozonation for Drinking Water Applications: Destruction of bacteria and viruses Oxidation of iron and manganese Heavy metal precipitation Colour destruction Taste improvement Algae and protozoa destruction Hardness reduction Hydrogen sulphide and mercaptans elimination
  • 47. Ozone chemical free treatments & applications Domestic/Municipal Cooling towers treatment Pulp & paper Boiler water treatment Mining (Cyanide,Arsenic) Chilled water treatment Pharmaceutical (Phenol ) Cutting fluids recycling Textile Barn disinfecting (air/water) Leather Hydroponics Petroleum/Petrochemicals Animal waste treatment Electroplating Water dripping treatment Heavy metal precipitation Animal drinking water Landfill leacheates Irrigation water disinfecting
  • 48. Ozone chemical free treatments & applications Drinking & water bottling Smoke & odour treatment Food Grain disinfecting Semiconductor wafers clean Fruit & vegetable storage Laundry water recycling Meat storage Med. instrument sterilization Slaughter house disinfecting Hospital air sterilization Fruits & vegetable wash Aqua-culture Food containers sterilizations Paper pulp bleach Wine/Beer SO2 replacement Sour gas desulphurization Chicken egg wash Zebra mussels treatment Ozonated meat grinders Rubber recycling Operation Theater For Disinfection
  • 49. The measure of an oxidiser and its ability to oxidise organic and inorganic material is its oxidation potential (measured in volts of electrical energy). Oxidation potential indicates the degree of chemical transformation to be expected when using various oxidants. It gauges the ease with which a substance loses electrons and is converted to a higher state of oxidation Theoretically the substance with the lower oxidation potential will be oxidised by the substance with the higher oxidation potential. A substance can only be oxidised by an oxidiser with a higher potential. The oxidation potentials of common oxidants and disinfectants associated with water and wastewater treatment are all of a lower oxidation potential than ozone. There is only one element with a higher oxidation potential than ozone and that is fluorine. Oxidation potential does not indicate the relative speed of oxidation nor how complete the oxidation reactions will be. Complete oxidation converts a specific organic compound to carbon dioxide and water. Oxidation reactions that take place during water treatment are rarely complete, due to the large quantity of contaminants and relatively short durations of time in which to oxidise the water pollutants. Although the relative position of an oxidant is indicative of its ability to oxidise other materials, it does not indicate how fast one material will be oxidised by another, nor how far toward completion (to carbon dioxide and water) the oxidation reaction will proceed.
  • 50. Post-Ozonation Requirements The ozonation treatment step is usually followed by : 1. Clarification: to precipitate oxidised organic and inorganic matter. 2. Filtration (nano, sand, charcoal): to remove precipitants. The use of activated carbon filters has the added advantage of adsorbing the excess unreacted, unrecycled ozone and allows it to convert back to oxygen. This increased understanding of ozone oxidation has lead to the broadening of its applications making it the one of the fastest growing market segments within the drinking water and waste water treatment industry. Other industries employing ozone treatment include the agricultural, food, pharmaceutical, and electronic industries. Lower ozone production costs have allowed this material from the past to have modern applications. Disclaimer: The articles about ozone are collected from several sources from the internet and does not necessarily reflect EnviroSafe applications and experience
  • 51. Comparative Analysis of Water Treatment Methods Criteria U.V. Radiation Ozone Chlorine ESSENTIAL Harmful By- Products By- NO NO YES Enviro. Impact Enviro. LOW LOW HIGH Bacteria Removal SOME YES YES Virus Removal NO YES SOME Lead Removal NO YES NO Manganese Removal NO YES SOME Iron Removal NO YES YES Odour Removal NO YES YES Colour Removal NO YES SOME DESIRABLE Op. Cost MED LOW MED Capital Cost MED HIGH MED Maintenance HIGH MED MED Complexity MED MED MED
  • 52. Chemical free Pool water treatment with Ozone Ozone can replace partially or totally Chlorine in the pool. It is many times more effective in getting rid of bacteria & viruses then Chlorine. It will maintain a very clean water without the use of the many chemicals used to disinfect, to adjust the PH, Alkalinity... By comparison to the Chlorine , Ozone water treatment system for pool is virtually maintenance free. All what you need is to install Ozonator , add the Ozone fix and enjoy. No Chlorine EVER!!!!
  • 53. Imagine your pool and spa with no chlorine. Yes, imagine yourself sitting in your spa with sparkling clean water, no smell of chlorine irritating your nose. Your bathing suit is not slowly disintegrating from the chlorine in the water. Yes, imagine you and your children swimming in a pool filled with sparkling water. Enjoy all the pool fun with out red burning eyes. The blond swimmers don't get green hair. Your skin is smooth and silky, no rash or itchiness here. The first concern of pool owners should be the safety of the water in your pool. OZONE is one of the strongest oxidizers available. Only fluorine is stronger. Chlorine is a weaker oxidizer. Ozone water treatment system has a quicker kill time of organisms and kills more types. OZONE is used to purify Olympic pools. In fact the athletes in the LA Olympics refused to swim in a pool purified by chlorine. We guarantee NO CHLORINE NEEDED EVER. Instead bromine is used. The bromide combines with the OZONE to form bromine. The bromine then reacts with the algae. Bromide is then released as a byproduct. The cycle begins again!! Bromides needs only to be added to replace that removed by water splashing out of the pool or exiting on the bodies of swimmers. An added advantage as you can see, is that there are no harmful byproducts. Ozone breaks down into oxygen. Chlorine on the other hand breaks down into trihalomethanes, which have been shown to increase the incidence of kidney, bladder and colon cancer. Another byproducts of chlorine plus urine and or perspiration are chloramines, which cause eye and skin irritation. THOUSANDS THAT TREAT THEIR POOLS THE BEST WAY DOES THIS SOUND TOO GOOD TO BE TRUE ?? THIS TIME THE TRUTH IS GOOD
  • 54. Ozone was first used in swimming pool water treatment in the 1950's. Since then its use has widely grown. There are over 30,000 swimming pools in Europe that are treated with ozone. The swimming pools for the Olympics have been treated with Ozone at least since 1986 for the Los Angeles Olympics. Most recently the Sydney Aquatic Center pool water was treated with Ozone. Well known water facilities using ozone to treat their water: Disneyland and Disney World for all their water features Mirage Resort, Las Vegas San Diego Zoo, San Diego, CA for their marine and Aquatic habitats Vancouver Aquarium, Vancouver, Canada -for their Sea mammal support systems Universal Studios, Jurassic Park, The Ride“ Many YMCA's and hotels Waterparks and aquatic centers
  • 55. WHAT HAPPENS IN YOUR SWIMMING POOL ? EACH swimmer brings into the pool: 300-400 million bacteria 300- 0.5 gr. of organic matter 30-50 cc of urine 30- Ozone water treatment system can take care of it! Ozone kills bacteria, viruses, spores, and mold and does it fast. Ozone pierces the cell wall of bacteria and fast. viruses killing them 3000 times faster than chlorine. Ozone was used to treat the water in the swimming pool that the AIDS infected blood of Greg Louganis contaminated. No one else contracted AIDS from that incident. one Ozone water treatment system advantages OZONE is produced on site-no storage or transport of dangerous chemicals site- OZONE kills all bacteria, viruses, fungi and parasites OZONE prevents calcium carbonate scaling and removes existing existing OZONE not used up slowly decomposes to oxygen up to the saturation point of oxygen in water this gives sparkling clean pool water OZONE use in the water does not cause discharge liabilities liabilities OZONE is not affected by pH of water, nor does it affect the pH of water OZONE causes increased flocculation of organic wastes, thus increasing the effectiveness of the thus sand filtration system of your pool.
  • 56. ARE YOU SURE IT WON'T NEED CHLORINE EVER ? YES, we are sure except sometimes for chock treatment in cold climates at the begining of the season. We use bromides instead of chlorine for residual disinfection and algae destruction. The bromine reacts with algae and turns to bromide. The bromide recombines with the ozone to reform bromine. This starts the cycle over again. Bromide is added in the beginning and additional bromide is needed only as water leaves the pool by splashing or on a swimmer's body as he/she exits There are several models you can choose from depending on the size & usage of your pool. The following are general guide lines Pool Volume O3 G/hr 2,000 Liter 2.5 to 3.0 4,000 Liter 5.0 6,000 liter 8.0 10,000 Liter 15.0 20,000 Liter 25.0 Disclaimer: The articles about ozone are collected from several sources from the internet and does not necessarily reflect Envirozone Technocraft Pvt. Ltd. applications and experience
  • 57. Ozone FAQ What is Ozone? Ozone (O3) is an allotrope of oxygen, the molecule consisting of three oxygen atoms instead of the more stable diatomic O2 Ozone is a pale blue gas at standard temperature and pressure. It forms a dark blue liquid below -112 ºC and a dark blue solid below -193 ºC. Ozone is a powerful oxidizing agent. It is also unstable, decaying to ordinary oxygen through the reaction: 2O3 -> 3O2. This reaction proceeds more rapidly with increasing temperature and decreasing pressure. Discovery of ozone Ozone was discovered by German-Swiss chemist Christian Friedrich Schönbein in 1840, who named it after the Greek word for smell (ozein), from the peculiar odor in lightning storms. (Source: OzoneWikipedia) Ozone application Sterilization and purification of water by the use of ozone has been used for may years in drinking water and Waste water treatment plants throughout the world. Ozone is very reactive form of oxygen that can destroy and enormous variety of liquid waste materials and toxins. Ozone regulations In Canada the Worker's Compensation Board of B.C. guidelines stipulate that continuous exposure 8 hours a day for 5 days per week in an environment containing .08 ppm. of ozone is safe. The output of the ozonator can be adjusted to be below these limits or others limits depending on the local regulations.
  • 58. For Sterilization, Disinfection & Air Purification
  • 60.
  • 61. Envirozone Technocraft Pvt Ltd. Regd. Office : # 906, Rajhans Tower, Opp. J.K. Tower, Ring Road, SURAT – 395002, Gujarat, INDIA. Phone : +91-261-6501355, Fax : +91-261-4002626 Website : www.indianozone.com Email : info@indianozone.com e.safe2007@gmail.com Thank You for being With Us……..