Lifecore RENOVA           ™


Internal Hex
Implant System
Surgical & Restorative Catalog
Table of Contents
              Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
              RENOVA Implant System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-5
              RENOVA Drill Sequence Charts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-7
              RENOVA Implants
                    RENOVA Tapered Implants . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
                    RENOVA Straight Implants . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
                    Cover Screws & Healing Abutments . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
              Cement-Retained Restorations
                    Cement-on-Crown (COC) Abutment System. . . . . . . . . . . . . . . . . . . . 11-13
              Screw-Retained Restorations
                    UCLA Abutment System. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14-16
                    Fixed Detachable Abutment System. . . . . . . . . . . . . . . . . . . . . . . . . . 17-19
              Overdenture Restorations
                    Snap Abutment System. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20-22
              Surgical Kit for RENOVA Tapered Implants . . . . . . . . . . . . . . . . . . . . . . . . . 23
              Surgical Instrumentation for RENOVA Tapered Implants . . . . . . . . . . . . 24-25
              Surgical Kit for RENOVA Straight Implants. . . . . . . . . . . . . . . . . . . . . . . . . . 26
              Surgical Instrumentation for RENOVA Straight Implants. . . . . . . . . . . . . 27-28
              Additional Surgical Instrumentation for Tapered & Straight Implants . . . 29-31
              Surgical Wrenches and Drivers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32-33
              Lab Tools and Other Products . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34-35
              Lifecore LC5000 Surgical Motor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36-37
              Tissue Regeneration Products
                    Capset® Calcium Sulfate Bone Graft Barrier. . . . . . . . . . . . . . . . . . . . . . . 38
                    TefGen® Regenerative Membranes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
              Warranty Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
              Order Form . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
              Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42




-2-                               For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300
Introduction

                 A Leader in Biotechnology …
                                          Lifecore Biomedical is dedicated to the development of technologically
                                          advanced, dependable products that offer long-term compatibility with the
                                          human body. Thousands of patients worldwide have benefited from Lifecore’s
                                          technology in dentistry, general surgery and ophthalmology. Founded in 1965,
                                          Lifecore is a publicly held company (Nasdaq: LCBM) headquartered in Chaska,
                                          Minnesota, USA.

                                          Lifecore’s Oral Restorative Division is focused on providing the highest quality
                                          surgical devices and applications for the global dental industry. The Division
                                          offers one of the most extensive product lines to address the many clinical
                                          situations faced by our clients. Lifecore offers two-stage internal and external
                                          hex implant systems and a single stage implant system. A complete family of
                                          restorative options are available to meet the unique needs of each patient. Visit
                                          us at www.lifecore.com to learn more.

                                          Our Commitment to Quality …
                                          Lifecore’s commitment to quality and service ensures that our products meet
                                          or exceed the highest standards set by the United States Food and Drug
                                          Administration, the European Community and other international agencies.
                                          Lifecore has earned ISO 9001 and CE Certifications, international symbols of
                                          quality system assurance and compliance.

                                          Lifecore has earned a reputation for quality by
                                          enforcing strict design and inspection criteria. Our 100%
                                          inspection of all critical dimensions of dental implants
                                          and prosthetic components has allowed Lifecore to
                                          maintain the tightest tolerances in the industry. In
                                          addition, Lifecore’s Lifetime Limited Warranty gives
                                          the clinician the added security of knowing that dental
                                          implants and prosthetics are covered throughout the
                                          patient’s lifetime.

                                          Our Commitment to Your Practice …
                                          Lifecore’s technical services department is available to consult with clients
                                          on questions related to case planning, component selection and step-by-step
                                          procedures for clinical and laboratory applications.

                                          Our family of Support Plus® Restorative Training Programs are recognized in the
                                          industry as the best referral based training courses available. Lifecore is certified
                                          through the Academy of General Dentistry, the American Dental Association and
                                          through the National Board of Certification to offer continuing education credits.

                                          Lifecore is committed to being the standard of comparison for product quality,
                                          education and customer service, and to be recognized as a company of
                                          dedication, honesty and integrity.

  For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300                                      -3-
RENOVA Implant System




                  Internal hex prosthetic connection for
                     superior esthetics and reliability

                    1mm machined titanium collar for
                        soft tissue maintenance

                     Parallel walled neck region with
                  circumferential grooves for crestal seal
                            and bone interlock

                      Lifecore’s proven RBM Surface


                   Straight and tapered designs expand
                             treatment options

                 Tapered design enables placement near
                  impinging anatomical structures while
STRAIGHT




                 maximizing prosthetic table diameter for

                                                                                                        TAPERED
                       natural emergence profile



                   Apical end design provides excellent
                  initial thread engagement and stability




 -4-                 For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300
Internal Hex Prosthetic Connection                                      Proven RBM Surface
                             Delivers superior strength and ease        Lifecore’s RENOVA, RESTORE® and STAGE-1™
                             of prosthetic indexability.                implants feature the RBM surface. Lifecore’s
                                                                        RBM, a roughened titanium surface, has
                             Beveled interface helps maximize           been in clinical use since 1997 and has
                             prosthetic stability and evenly            achieved a high level of clinical acceptance.
                             transfers occlusal forces to the
                             implant.                                   Lifecore’s RBM (Resorbable Blast Media)
                                                                                                                                  2000X RBM Surface
                                                                        substantially increases bone-to-implant
                                                                        contact and mechanical bone interlock, with
                             Deep internal hex connection
                                                                        approximately 250% more surface
                             simplifies abutment seating and
                                                                        roughness than a machined titanium
                             provides excellent tactile feel for
                                                                        surface. Safety and biological compatibility
                             added confidence.
                                                                        are ensured through the exclusive use of
                                                                        biocompatible calcium phosphate ceramic
RENOVA Prosthetics                                                      media in the roughening process.
                                                                                                                                   500X RBM Surface
The Tapered and Straight implant
designs share the same prosthetics.                                     As a clinician, you can have confidence in the Lifecore implant
                                                                        you choose knowing that Lifecore is an established leader in RBM
                                                                        surface technology. Our three implant designs, coupled with our
The RENOVA system offers
                                                                        RBM surface technology, maximize your opportunity for clinical
abutment systems for:
                                                                        flexibility and optimal treatment outcomes.
• Cement-Retained restorations
• Screw-Retained restorations                                                                            Mechanical interlock of bone into the
                                                                                                         implant surface topography is evident.
• Overdenture restorations                                                                               A direct bone-to-implant interface is
                                                                                                         observed at 100x magnification.1

                                                                                                         References:
                                                                                                         1. Sanz A, et al. Experimental study of bone
                                                                                                         response to a new surface treatment of
                                                                                                         endosseous titanium implants. Implant
                                                                                                         Dentistry. 2001; 10:126-131.




     For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300                                                               -5-
Drill Sequence RENOVA Tapered Implants
 SDI 3.75mm RENOVA Tapered Implant




              1                               2                         3                           4                          5                         6
      2.3mm Round Bur                2.0mm Initial Drill     3.75mm Intermediate Drill 3.75mm Finishing Drill             3.75mm Tap             3.75 x 13mm Implant




 RDI 4.5mm RENOVA Tapered Implant




              1                               2                          3                          4                          5                         6
      2.3mm Round Bur                2.0mm Initial Drill      4.5mm Intermediate Drill     4.5mm Finishing Drill           4.5mm Tap             4.5 x 13mm Implant




 Depth Marking System (for Tapered Implants)




                                                                                         13mm
                                                                                                     NOTE: Drill stops and bands reference
                                                                                                     the insertion depth for the corresponding
                                                                                                     implant length.

        0mm
                     ≤0.36mm
           Initial             Intermediate            Finishing             Tap
            Drill                  Drill                 Drill


-6-                                                                  For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300
Drill Sequence Charts
Drill Sequence RENOVA Straight Implants
SDI 3.75mm RENOVA Straight Implant




    1                   2               3                4                5                6                   7                  8                9
  2.3mm             2.0mm            2.35mm           2.35mm          2.8mm Drill    3.25mm Drill         3.75mm               3.75mm Tap      3.75 x 13mm
 Round Bur        Initial Drill        Drill        Depth Gauge                                        Countersink Drill                          Implant


RDI 4.75mm RENOVA Straight Implant




    1                 2             3              4              5           6             7              8               9            10          11
 2.3mm             2.0mm          2.35mm         2.35mm        2.8mm       3.25mm      3.25/4.25mm      4.25mm     4.75mm             4.75mm    4.75 x 13mm
Round Bur        Initial Drill      Drill      Depth Gauge      Drill        Drill       Pilot Drill      Drill Countersink Drill       Tap        Implant


Depth Marking System (for Straight Implants)




         16mm

         13mm
        11.5mm
                                                             NOTE: Drill bands reference the insertion depth
         10mm                                                for the corresponding implant length and do not
           8mm                                               indicate actual millimeter drill length.

         0mm
     ≤1.14mm
                     3.25x16mm          3.25x11.5mm
                        Drill               Drill


    For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300                                                                 -7-
RENOVA Implants

Lifecore RENOVA Tapered Implants
                      Features:
                      ●    Tapered implant design.
                      ●    Lifecore RBM Surface.
                      ●    Cover Screw and pre-mounted, color-coded Placement Head (3.5mm) included
                           with each implant.
                      ●    Packaged to minimize handling during placement.
                      ●    Gamma Sterilized.

                      Instrumentation Required:
                      ●    RENOVA Tapered Implant Surgical Kit
                      ●    .048" Hex Driver for Placement Head and Cover Screw




SDI 3.75mm RBM Tapered Implant
Description                        Catalog No.                                                            3.75mm

3.75 x 10mm                        14000
3.75 x 11.5mm                      14001
3.75 x 13mm                        14002
                                                                                                 length
3.75 x 14.5mm                      14003



                                                                                                           2.8mm
                                                                                                           Apical
                                                                                                          Diameter




 RDI 4.5mm RBM Tapered Implant
Description                        Catalog No.                                                            4.5mm
4.5 x 8.5mm                        14004
4.5 x 10mm                         14005
4.5 x 11.5mm                       14006
4.5 x 13mm                         14007                                                         length




                                                                                                           3.0mm
                                                                                                           Apical
                                                                                                          Diameter




-8-                                  For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300
Lifecore RENOVA Straight Implants
                                  Features:
                                  ●        Straight (parallel walled) implant design.
                                  ●        Lifecore RBM Surface.
                                           Cover Screw and pre-mounted, color-coded Placement Head (3.5mm) included




                                                                                                                            Healing Abutments
                                  ●
                                           with each implant.




                                                                                                                               Implants &
                                  ●        Packaged to minimize handling during placement.
                                  ●        Gamma Sterilized.

                                  Instrumentation Required:
                                  ❍        RENOVA Straight Implant Surgical Kit
                                  ❍        .048" Hex Driver for Placement Head and Cover Screw




SDI 3.75mm RBM Straight Implant
Description                                           Catalog No.                                           3.75mm

3.75 x 8mm                                            13000
3.75 x 10mm                                           13001
3.75 x 11.5mm                                         13002
3.75 x 13mm                                           13003                                        length
3.75 x 16mm                                           13004




RDI 4.75mm RBM Straight Implant
Description                                           Catalog No.                                           4.75mm
4.75 x 8mm                                            13005
4.75 x 10mm                                           13006
4.75 x 11.5mm                                         13007
4.75 x 13mm                                           13008                                       length
4.75 x 16mm                                           13009




     For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300                             -9-
Cover Screws & Healing Abutments
Cover Screws
                       Features:
                       ●    Included with all RENOVA implants.
                       ●    Offered separately for spare or replacement use.

                       Instrumentation Required:
                       ❍    .048" Hex Driver

                                                     SDI 3.75mm                          RDI 4.5/4.75mm
                             Description                 Catalog No.                            Catalog No.
                             Cover Screw                   10032                                 10033


Healing Abutments
                       Features:
                       ●    Healing Abutments are designed to achieve optimal contouring of soft tissue,
                            which provides for more aesthetic restorations.
                       ●    Occlusal surface is labeled with the implant prosthetic table (SDI and RDI)
                            and cuff height.

                       Instrumentation Required:
                       ❍    .048" Hex Driver



  SDI 3.75mm Healing Abutment
 Cuff Height                           Catalog No.
 1.5mm                                 10035
 3mm                                   10036
 5mm                                   10037




  RDI 4.5/4.75mm Healing Abutment
 Cuff Height                           Catalog No.
 1.5mm                                 10038
 3mm                                   10039
 5mm                                   10040




-10-                                       For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300
Cement-Retained Restorations

Cement-On Crown (COC)                                                                    Technical Considerations:
                                                                                         ❍       A minimum inter-occlusal clearance of 4.0mm plus
Abutment System                                                                                  the additional height of the restoration is required
                                                                                                 between the implant prosthetic table and the
Features:                                                                                        occlusal plane.
●            Cement-on Crown (COC) Abutments are intended                                ❍       It is recommended that bulk abutment reduction be
             for cement-retained restorations where conventional                                 performed outside of the mouth due to risk of heat
             crown and bridge techniques are desired. The COC                                    transfer to the implant.
             Abutment can be used for single or multi-unit (splinted)                    ❍       COC Abutments are made of titanium and are not
             restorations.                                                                       designed for direct casting to the abutment.

●            COC Abutments can be prepared as needed and
             impressioned directly using conventional crown                              Instrumentation Required:
             and bridge techniques, eliminating the need for                             ❍       .048" Hex Driver
             an impression post, analog and other prosthetic
             components. These abutments may also be used
             for provisional (temporary) restorations.
                                                                                         Torque Recommendation:
                                                                                         ❍       30 Ncm for Abutment Screw




                                                                                                                                                                                Prosthetics
Laboratory




                                                                              .048” Hex Driver
                                                                                                    15° Angled                                        Straight Locking
                                                                                                  COC Abutment                                        COC Abutment




                                                                                                                                    Implant
                                                                                                                                    Analog




                                                                                                                                              Implant
                                                                                                                                              Impression
Prosthetic




                15° Angled                                        Straight Locking
              COC Abutment                                        COC Abutment                                                                Post (Hexed)




                                       Abutment                                                                             Implant
                                  Impressioned Directly                                                               Impressioned Directly



                                                                                            Healing Abutment
Surgery




                                                          Tapered Implant                          Straight Implant




             For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300                                                                        -11-
Cement-Retained Restorations
Straight Locking Cement-On Crown (COC) Abutments
                          ●    For use in single or multi-unit (splinted) restorations.
                          ●    Abutment margin can be prepared as necessary to follow gingival contours.
                          ●    COC Abutment may be impressioned directly using conventional crown
                               and bridge impression techniques. Alternately, a locking implant
                               impression post can be used to impression the Implant; allowing the
                               laboratory to prepare the abutment and fabricate the restoration.
                          ●    Abutments include .048” hex titanium abutment screw. Additional screws
                               are available separately.

                                              SDI 3.75mm                           RDI 4.5/4.75mm
                 Description                      Catalog No.                            Catalog No.
                 COC Abutment
                 with Screw                         43089                                  43090
                 Abutment Screw, Ti                 43092                                  43092




Angled Locking Cement-On Crown (COC) Abutments
                          ●    For use in single or multi-unit (splinted) restorations where angle
                               correction is needed.
                          ●    Pre-machined margins simplify abutment preparation and may be
                               additionally prepared to follow gingival contours.
                          ●    COC Abutment may be impressioned directly using conventional crown
                               and bridge impression techniques. Alternately, a locking implant
                               impression post can be used to impression the implant; allowing the
                               laboratory to prepare the abutment and fabricate the restoration.
                          ●    Abutments include .048” hex titanium abutment screw. Additional screws
                               are available separately.

                                              SDI 3.75mm                           RDI 4.5/4.75mm
                 Description                      Catalog No.                            Catalog No.
                 15°, 2mm Cuff                     43094                                   43096
                 Abutment Screw, Ti                43100                                   43100




-12-                             For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300
Implant Impression Posts (UCLA type)
                                             ●     Used for single or multi-unit (splinted) restorations.
                                             ●     Unique 3-piece design includes a long screw (open tray impressions) and
                                                   a short screw (closed tray impressions).
                                             ●     Transfers soft-tissue contours to the dental laboratory.

                                                                     SDI 3.75mm                 RDI 4.5/4.75mm
                                             Description                Catalog No.                   Catalog No.
                                             Implant
                                             Impression Post              43127                        43128




Implant Analogs
                                             ●    Replicates the implant for use in the dental laboratory model.




                                                                                                                               Prosthetics
                                             ●    Stainless steel design allows use during soldering procedures.


                                                                        SDI 3.75mm              RDI 4.5/4.75mm
                                             Description                   Catalog No.               Catalog No.
                                             Implant Analog                  43129                     43130




  For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300                                  -13-
Screw-Retained Restorations

UCLA Abutment System                                                             Technical Considerations:
                                                                                 ❍      A minimum inter-occlusal clearance of 4.0mm
Features:                                                                              for the SDI and RDI UCLA Abutments is required
●            The UCLA Abutment System can be used for single or                        between the implant prosthetic table and the top
             multi-unit (splinted) crown and bridge restorations. It                   of the abutment screw when seated.
             can also be used for bar attachment retained
             overdenture restorations.                                           Instrumentation Required:
                                                                                 ❍      .048” Hex Driver
●            UCLA Abutments are used to fabricate highly
             aesthetic custom restorations that attach directly                  Torque Recommendation:
             to the implant.                                                     ❍      30 Ncm for Abutment Screws


                                                                         .048” Hex Driver
Laboratory




               UCLA Gold/Plastic                             UCLA                                        UCLA                                         UCLA
                Sleeve (Locking)                         Temporary                                       Temporary                                    Gold/Plastic
                                                             Sleeve                                      Sleeve                                       Sleeve
                                                          (Locking)                                      (Non-                                        (Non-Locking)
                                                                                                         Locking)


                                                                                      Implant
                                                                                      Analog
Prosthetic




                             Implant                                                                                                         Implant
                     Impression Post                                                                                                         Impression Post




                                       Single Unit                                                                   Multi-Unit (Splinted)
                                       Restorations                                                                     Restorations



                                                                                      Healing Abutment
Surgery




                                                      Tapered Implant                           Straight Implant




-14-                                                           For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300
UCLA Gold/Plastic Combo Sleeve
                                             ●    The Gold/Plastic Combo combines the precision fit of a machined
                                                  interface with the convenience of a castable plastic chimney.
                                             ●    Specially designed geometry on the plastic chimney improves wax retention.
                                             ●    Offered in both locking and non-locking versions.
                                             ●    Includes a titanium .048” hex abutment screw.

                                                                        SDI 3.75mm                  RDI 4.5/4.75mm
                                             Description                   Catalog No.                   Catalog No.
                                             Locking                         43006                         43007
                                             Non-Locking                     43009                         43010




                                                                                                                               Prosthetics
Abutment Screws for                          ●    Titanium screw included with each abutment and offered separately.
UCLA Abutments                               ●    .048” hex.
                                             ●    Torque recommendation – 30Ncm.



                                                                           SDI 3.75mm             RDI 4.5/4.75mm
                                             Description                       Catalog No.             Catalog No.
                                             Abutment Screw, Ti                  43116                   43116




  For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300                                  -15-
Implant Impression Posts (UCLA type)
                        ●    Used for single or multi-unit (splinted) restorations.
                        ●    Unique 3-piece design includes a .048” hex long screw (open tray
                             impressions) and a short screw (closed tray impressions).
                        ●    Transfers soft-tissue contours to the dental laboratory.


                                                 SDI 3.75mm                        RDI 4.5/4.75mm
                        Description                 Catalog No.                          Catalog No.
                        Implant
                        Impression Post               43127                                43128




Implant Analogs
                        ●    Replicates the implant for use in the dental laboratory model.
                        ●    Stainless steel design allows use during soldering procedures.

                                                   SDI 3.75mm                        RDI 4.5/4.75mm
                        Description                   Catalog No.                         Catalog No.
                        Implant Analog                  43129                               43130




UCLA Temporary Sleeve
                        ●    Titanium Temporary Sleeves provide a textured surface for acrylic when
                             constructing provisional restorations.
                        ●    Available in non-hexed for multi-unit (splinted) restorations and hexed for
                             single tooth restorations.
                        ●    Includes a titanium .048" hex abutment screw.


                                                   SDI 3.75mm*                       RDI 4.5/4.75mm*
                        Description                   Catalog No.                          Catalog No.
                        Sleeve, Hexed                   43110                                43111
                        Sleeve, Non-Hexed               43113                                43114



                        *Call for availability




-16-                             For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300
Screw-Retained Restorations

     Fixed Detachable Abutment System
          Features:
          ●    The Fixed Detachable Abutment System is designed for                         ❍     A minimum inter-occlusal clearance of 6.9mm is
               multi-unit (splinted) crown and bridge restorations.                               required between the implant prosthetic table and the
          ●    It is also commonly used for bar attachment retained                               top of the coping screw when seated.
               overdenture restorations.                                                    ❍     The tapered 12° side wall allows up to 24° of
          ●    The Fixed Detachable Abutment provides excellent                                   divergence between adjacent abutments.
               stability and allows for easier path of insertion due
               to its tapered design.                                                       Instrumentation Required:
                                                                                            ❍     .062” Hex Driver

          Technical Considerations:




                                                                                                                                                                            Prosthetics
                                                                                            .048"
                                                                                            Hex Driver
Laboratory




                                                                                           Coping Screw
                                                                                           (.048" Hex)




                                                                                                           Fixed
                                           Waxing                            Fixed                         Detachable
                                              Pin                            Detachable                    Plastic Sleeve
                                                                             Gold Sleeve




                                                                                           Fixed Detachable
                                                                                           Abutment Analog
Prosthetic




                                                                  1-Piece
                                                               Impression
                                                                     Post
                                                                                                              2-Piece                       Multi-Unit (Splinted)
                                              .048"                                                           Impression Post
                                         Hex Driver                                                                                         Restorations

                                             Healing                             Fixed                                          .062" Hex
                                                Cap                         Detachable                                          Driver
                                                                             Abutment


                                                                                              AC Healing
                                                                                              Abutment
Surgery




                                                                                                                                             Regular Diameter (RD)
                                                                                                                                             components shown
                              Components not shown to scale.




              For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300                                                                   -17-
Screw-Retained Restorations

Fixed Detachable Abutments
                                    ●    Torque recommendation – 30Ncm.

                                    Instrumentation required:
                             cuff   ●    .062" Hex Driver.

                                                                                      SDI 3.75mm               RDI 4.5/4.75mm
                                    Description                                          Catalog No.                  Catalog No.
                                    2mm Cuff, .062" Hex                                    43118                        43120
                                    4mm Cuff, .062" Hex                                    43119                        43121



Healing Cap for Fixed Detachable Abutments
                                    ●    Protects the abutment's internal threads and seating surface
                                         during healing.
                                                                                       SDI 3.75mm              RDI 4.5/4.75mm
                                    Description                                           Catalog No                  Catalog No.
                                    Healing Cap, .048" Hex                                R2800-00                    R2800-00




Impression Posts for Fixed Detachable Abutments
                                    ●    1-piece design is used for closed tray impressions.
                                    ●    2-piece design is used for open tray impressions.



       Impression Post, 1-Piece

                                                                                      SDI 3.75mm                RDI 4.5/4.75mm
                                    Description                                           Catalog No.                 Catalog No.
                                    1-Piece, 9mm, .048" Hex                               R9615-48                    R9615-48
                                    2-Piece, 9mm, .048" Hex                               R9515-48                    R9515-48




       Impression Post, 2-Piece




-18-                                              For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300
Analog for Fixed Detachable Abutments
                                              ●     Replicates the Fixed Detachable Abutment for use by the
                                                    dental laboratory.
                                              ●     Stainless steel design allows use during laboratory
                                                    soldering procedures.

                                                                                          SDI 3.75mm          RDI 4.5/4.75mm
                                              Description                                  Catalog No.           Catalog No.
                                              Fixed Detachable Analog                      410530-4              410530-4




Gold Sleeve and Plastic Sleeve for Fixed Detachable Abutments
                                              ●    Gold Sleeve provides a precision machined interface
                                                   between the restoration and the abutment. A Waxing Pin




                                                                                                                                       Prosthetics
                                                   is available for waxing additional vertical height.
                                              ●    Plastic Sleeve provides an economical alternative to Gold
                                                   Cylinders and the extended chimney eliminates the need
                                                   for a Waxing Pin.
  Gold Sleeve          Plastic Sleeve         ●    Use with titanium coping screws, which are
                                                   purchased separately.

                                                                                          SDI 3.75mm          RDI 4.5/4.75mm
                                              Description                                   Catalog No.          Catalog No.
                                              Gold Sleeve                                  410720-4              410720-4
                                              Plastic Sleeve, 12mm                         410450-4L             410450-4L
                                              Waxing Pin                                   R9229-48              R9229-48




Coping Screw for Fixed Detachable Abutments
                                              ●     Use with Fixed Detachable Abutment Gold and
                                                    Plastic Sleeves.
                                              ●     Torque recommendation - 20Ncm.


                                                                                          SDI 3.75mm          RDI 4.5/4.75mm
                                              Description                                   Catalog No.           Catalog No.
                                              .048" Hex (1.5mm head)                        R9490-48              R9460-48




   For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300                                         -19-
Overdenture Restorations

 Snap Abutment System
 Features:
 ●            The Snap Abutment System is used with two or more implants for implant attachment retained
              overdenture restorations.
 ●            The Snap Abutment threads directly into the implant.
 ●            The Snap Abutment assembly is processed into the denture base either chairside or at the dental laboratory.
 ●            Replacement retention inserts are available in a choice of 8, 10 and 12 Newtons.

 Technical Considerations:
 ❍            A minimum inter-occlusal clearance of 7.0mm plus the cuff height is required.
 ❍            Implants must be relatively parallel to one another – less than 20º total divergence.




                                                                                                                                       Snap Abutment Assembly



                                                                                             Overdenture                               Snap
                                                                                          Abutment Driver
 Laboratory




                                                                                                                                       Abutment




                                                                                                                                        Implant
                                                                                                                                        Analog




                                    Snap Abutment Assembly




                                                                                                                                             Implant
 Prosthetic




                                                                                                                                             Impression Post

                                     Snap                    Abutment
                                 Abutment                    Analog

                        Overdenture                                            .048” Hex Driver
                       Abutment Driver

                                        Abutment                                                                              Implant
                                   Impressioned Directly                                                                Impressioned Directly




                                                                                                  Healing Abutment
 Surgery




                                                             Tapered Implant                         Straight Implant




-20-                                                                 For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300
Snap Abutments                                          ●    Snap Abutments are packaged with a Snap Abutment Assembly
                                                             [8 Newtons (N) – yellow] and laboratory spacer.
                                                        ●    Torque Recommendation – 30Ncm.
                        Snap Abutment
                        Assembly
                                                        Instrumentation Required:
                                                        ❍    Overdenture Abutment Driver
                                cuff
                                                                               SDI 3.75mm             RDI 4.5/4.75mm
                                                        Description                Catalog No.              Catalog No.
           Snap Abutment                                1mm Cuff                    43102                     43106
                                                        2mm Cuff                    43103                     43107
                                                        3mm Cuff                    43104                     43108
                                                        4mm Cuff                    43105                     43109


Snap Abutment Accessories
             Snap Abutment
             Assembly


                           8N                           Description                                      Catalog No.

                                  Retaining Retention   Abutment Analog                                  L2804-01
                                    Ring      Insert
                                                        Snap Retention Inserts, 8N,
                           10 N
                                                        Qty 6 (includes blue retaining rings)            L2806-08
                                                        Snap Retention Inserts, 10N,
                                  Retaining Retention   Qty. 6 (includes blue retaining rings)           L2806-10




                                                                                                                                 Instrumentation & Motor
                                    Ring      Insert
                                                        Snap Retention Inserts, 12N,
                           12 N                         Qty. 6 (includes blue retaining rings)           L2806-12
                                  Retaining Retention   Snap Retention Inserts, Multi-Pack,
                                    Ring      Insert    Qty. 6 (includes blue retaining rings)           L2806-13
                                                        Assembly (8N) with lab spacer                    L2807-01
                                                        Seating Tool                                     L2808-01
Abutment      Seating
 Analog        Tool




     For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300                                 -21-
Implant Impression Posts (UCLA type)
                        ●    Used for single or multi-unit (splinted) restorations.
                        ●    Unique 3-piece design includes a .048" hex long screw (open tray
                             impressions) and a short screw (closed tray impressions).
                        ●    Transfers soft-tissue contours to the dental laboratory.

                                                   SDI 3.75mm                             RDI 4.5/4.75mm
                        Description                   Catalog No.                               Catalog No.
                        Implant
                        Impression Post                 43127                                     43128




Implant Analogs
                        ●    Replicates the implant for use in the dental laboratory model.
                        ●    Stainless steel design allows use during soldering procedures.

                                                     SDI 3.75mm                          RDI 4.5/4.75mm
                        Description                    Catalog No.                               Catalog No.
                        Implant Analog                   43129                                     43130




-22-                                  For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300
Surgical Kit for RENOVA Tapered Implants
                                                                          The RENOVA Tapered Implant Surgical Kit
                                                                          contains the instrumentation needed to place
                                                                          RENOVA 3.75 and 4.5mm tapered implants.



                                                                          Kit Features:
                                                                          ●   Simple step-by-step drill sequences.
                                                                          ●   RENOVA instrumentation offers improved efficiency,
                                                                              longevity and overall ease of use.
                                                                          ●   Includes drills and taps for use with external irrigation.
Description                                                 Catalog No.
Surgical Kit for Tapered Implants                           14012



Surgical Kit Item List:
2.3mm Round Marking Bur                          3.75 x 11.5mm Surgical Tap                     .048" Hex Swivel Head Driver, Long
2.0mm Initial Drill                              3.75 x 13mm Surgical Tap                       .048" Hex Driver, Latch-Type, Short
3.75 x 10mm Intermediate Drill                   3.75 x 14.5mm Surgical Tap                     Conversion Handle for
3.75 x 11.5mm Intermediate Drill                 4.5 x 8.5mm Surgical Tap                           Latch-Type Instruments
3.75 x 13mm Intermediate Drill                   4.5 x 10mm Surgical Tap                        Ratchet Extender, Short & Long
                                                                                                Placement Head Assembly Sleeves,
3.75 x 14.5mm Intermediate Drill                 4.5 x 11.5mm Surgical Tap
                                                                                                    SDI & RDI
3.75 x 10mm Finishing Drill                      4.5 x 13mm Surgical Tap
                                                                                                Component Pack
3.75 x 11.5mm Finishing Drill                    SDI 3.5mm NP Placement Head




                                                                                                                                           Instrumentation & Motor
                                                                                                Grommet Plugs, 2 Packs of 10
3.75 x 13mm Finishing Drill                      SDI 5.5mm NP Placement Head
                                                                                                Cleaning Detergent
3.75 x 14.5mm Finishing Drill                    RDI 3.5mm NP Placement Head
4.5 x 8.5mm Intermediate Drill                   RDI 5.5mm NP Placement Head
4.5 x 10mm Intermediate Drill                    SDI 15mm NP Placement Head*
4.5 x 11.5mm Intermediate Drill                  RDI 15mm NP Placement Head*
4.5 x 13mm Intermediate Drill                    Locking Drill Extender
4.5 x 8.5mm Finishing Drill                      Surgical Ratchet
4.5 x 10mm Finishing Drill                       Stabilizing Wrench
4.5 x 11.5mm Finishing Drill                     Hand Adapter
4.5 x 13mm Finishing Drill                       Ratchet Adapter, 8mm
3.75mm Countersink Drill, Tapered                Ratchet/Tap Adapter, 12mm
4.5mm Countersink Drill, Tapered                 Handpiece Adapter
3.75 x 10mm Surgical Tap                         .048" Hex Swivel Head Driver, Short




* Call for availability


     For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300                                           -23-
Surgical Instrumentation for
 RENOVA Tapered Implants
For recommended drill sequences and details on drill depth markings, refer to page 6.

Round Bur & Initial Drill
                                              ●     Round Bur is used for marking the implant site prior to beginning the
                                                    drilling sequence.
                                              ●     Initial Drill is the first drill used for all RENOVA Tapered Implants.

                                               Description                                                  Catalog No.
             Round Bur
                                               Round Marking Bur, 2.3mm                                     L1405-23-00
                                               2.0mm Initial Drill                                          14071
                     Initial Drill




Drills for RENOVA Tapered
●      Specific drill is used for each implant size.
●      For use with external irrigation.




        SDI 3.75mm Tapered Intermediate Drills                                     SDI 3.75mm Tapered Finishing Drills
    Description                       Catalog No.                           Description                           Catalog No.
    3.75 x 10mm                        14072                                3.75 x 10mm                             14076
    3.75 x 11.5mm                      14073                                3.75 x 11.5mm                           14077
    3.75 x 13mm                        14074                                3.75 x 13mm                             14078
    3.75 x 14.5mm                      14075                                3.75 x 14.5mm                           14079




         RDI 4.5mm Tapered Intermediate Drills                                     RDI 4.5mm Tapered Finishing Drills
    Description                       Catalog No.                           Description                           Catalog No.
    4.5 x 8.5mm                        14080                                4.5 x 8.5mm                             14084
    4.5 x 10mm                         14081                                4.5 x 10mm                              14085
    4.5 x 11.5mm                       14082                                4.5 x 11.5mm                            14086
    4.5 x 13mm                         14083                                4.5 x 13mm                              14087




-24-                                                   For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300
Surgical Taps for RENOVA Tapered Implants

                                             ●    For pre-tapping bone prior to tapered implant placement.
                                             ●    Latch-type tap can be used in a handpiece or can be operated manually
                                                  when used with the Surgical Ratchet (L1702-01) and Ratchet/Tap
                                                  Adapter (L1806-05).


                                                      SDI 3.75mm Tapered Surgical Tap
                                             Description                                 Catalog No.
                                             3.75 x 10mm                                  14088
                                             3.75 x 11.5mm                                14089
                                             3.75 x 13mm                                  14090
                                             3.75 x 14.5mm                                14091




                                                                                                                             Instrumentation & Motor
                                                       RDI 4.5mm Tapered Surgical Tap
                                             Description                                 Catalog No.
                                             4.5 x 8.5mm                                  14092
                                             4.5 x 10mm                                   14093
                                             4.5 x 11.5mm                                 14094
                                             4.5 x 13mm                                   14095




  For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300                                -25-
Surgical Kit for RENOVA Straight Implants
                                                            The RENOVA Straight (parallel walled) Implant Surgical Kit
                                                            contains the instrumentation needed to place RENOVA 3.75
                                                            and 4.75mm straight implants.
                                                            Kit Features:
                                                            ●    Simple step-by-step drill sequences.
                                                            ●    RENOVA instrumentation offers improved efficiency,
                                                                 longevity and overall ease of use.
                                                            ●    Includes drills and taps for use with external irrigation.


Description                                  Catalog No.
Surgical Kit for Straight Implants           13010



Surgical Kit Includes:
2.3mm Round Marking Bur              2.35mm Depth Gauge                              Conversion Handle for Latch-Type
2.0mm Initial Drill                  SDI 3.5mm NP Placement Head                         Instruments
2.35 x 11.5mm Drill                  SDI 5.5mm NP Placement Head                     Ratchet Extender, Short & Long
                                                                                     Placement Head Assembly Sleeves,
2.35 x 16mm Drill                    RDI 3.5mm NP Placement Head
                                                                                         SDI & RDI
2.8 x 11.5mm Drill                   RDI 5.5mm NP Placement Head
                                                                                     Component Pack
2.8 x 16mm Drill                     SDI 15mm NP Placement Head*
                                                                                     Grommet Plugs, 2 Packs of 10
3.25 x 11.5mm Drill                  RDI 15mm NP Placement Head*
                                                                                     Cleaning Detergent
3.25 x 16mm Drill                    Locking Drill Extender
3.25/4.25mm Pilot Drill              Surgical Ratchet
4.25 x 11.5mm Drill                  Stabilizing Wrench
4.25 x 16mm Drill                    Hand Adapter
3.75mm Countersink Drill             Ratchet Adapter, 8mm
4.75mm Countersink Drill             Ratchet/Tap Adapter, 12mm
3.75 x 11.5mm Surgical Tap           Handpiece Adapter
3.75 x 16mm Surgical Tap             .048" Hex Swivel Head Driver, Short
4.75 x 11.5mm Surgical Tap           .048" Hex Swivel Head Driver, Long
4.75 x 16mm Surgical Tap             .048" Hex Driver, Latch-Type, Short




* Call for availability




-26-                                       For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300
Surgical Instrumentation for RENOVA Straight Implants
For recommended drill sequences and details on drill depth markings, refer to page 7.

Round Bur & Initial Drill
                                               ●     Round Bur is used for marking the implant site prior to beginning the
                                                     drilling sequence.
                                               ●     Initial Drill is the first drill used for all RENOVA Straight Implants.

                                                     Description                                         Catalog No.
                                                     Round Marking Bur, 2.3mm                            L1405-23-00
           Round Bur    Initial Drill                2.0mm Initial Drill                                 14071

Drills for RENOVA Straight Implants
Initial Drills                                 ●
                                               ●
                                                     For use with external irrigation.
                                                     Offered in 2 lengths.
                                                     Short – for RENOVA straight implants up to 11.5mm
                                                     Long – for RENOVA straight implants up to 16mm
                                                     Description                                        Catalog No.
                                                     2.35 x 11.5mm Drill                                13031
                                                     2.35 x 16mm Drill                                  13032




Intermediate & Finishing Drills




                                                                                                                                      Instrumentation & Motor
                                                     Description                                        Catalog No.
                                                     2.8 x 11.5mm Drill                                 13033
                                                     2.8 x 16mm Drill                                   13034
                                                     3.25 x 11.5mm Drill                                13035
                                                     3.25 x 16mm Drill                                  13036
                                                     4.25 x 11.5mm Drill                                13038
                                                     4.25 x 16mm Drill                                  13039




Pilot Drill                                    ●     Pilot Drill helps ensure a smooth and accurate transition between the
                                                     3.25mm and 4.25mm drills.
                                               ●     For use with external irrigation.

                                                     Description                                        Catalog No.
                                                     3.25/4.25 Pilot Drill                              13037


Countersink Drills                             ●     Contours ridge prior to placing 3.75mm and 4.75mm RENOVA Straight
                                                     Implants, allowing implant and cover screw placement at or below the
                                                     surrounding bone level.
                                               ●     For use with external irrigation.

                                                     Description                                        Catalog No.
                                                     3.75mm Countersink Drill                           13040
                                                     4.75mm Countersink Drill                           13041


    For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300                                       -27-
Surgical Instrumentation for
RENOVA Straight Implants
Surgical Taps for RENOVA Straight Implants
                     ●    For pre-tapping bone prior to implant placement.
                     ●    Latch-type tap can be used in a handpiece or can be operated manually
                          when used with the Surgical Ratchet (L1702-01) and Ratchet/Tap
                          Adapter (L1806-05).
                     ●    For use with external irrigation.
                     ●    Offered in 2 lengths.
                          Short – for RENOVA straight implants up to 11.5mm
                          Long – for RENOVA straight implants up to 16mm



                         SDI 3.75 Straight Surgical Taps
                          Description                                           Catalog No.
                          3.75 x 11.5mm Tap                                     13042
                          3.75 x 16mm Tap                                       13043




                         RDI 4.75 Straight Surgical Taps
                          Description                                           Catalog No.
                          4.75 x 11.5mm Tap                                     13044
                          4.75 x 16mm Tap                                       13045




-28-                           For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300
Additional Surgical Instrumentation
for Tapered and Straight Implants
Depth Gauge                                  ●     Verifies depth of the surgical site.
                                             ●     Depth marks correspond to implants lengths.

                                                    Description                                                                 Catalog No.
                                                    2.35mm Depth Gauge (for straight implants)                                  10589




Parallel Pins                                ●     Used as a visual guide during surgery to help ensure parallel
                                                   implant placement.

                                                    Description                                                                 Catalog No.
                                                    2.0mm Parallel Pin (tapered & straight implants), 2-pk                      10028*

                                                    2.35/2.8mm Parallel Pin (straight implants), 2-pk                           13029*


Surgical Ratchet, Adapter and Extenders
 Description                                Catalog #                      ●   Ratchet is used for manual operation of the Surgical
                                                                               Taps and/or final tightening of the implant.
 Surgical Ratchet                          L1702-01
                                                                           ●   Ratchet Extenders enable clearance of adjacent teeth.
 Ratchet Adapter, 8mm                      L1806-04
   (for NP Placement Heads)




                                                                                                                                                     Instrumentation & Motor
 Ratchet/Tap Adapter, 12mm                 L1806-05
   (for NP Placement Heads &                                                                           Surgical Ratchet
   Latch-Type Surgical Taps)
 Ratchet Extender, Short & Long            L1703-01
   (to extend the Ratchet
   Adapters)
 Replacement O-Rings for                   L1806-03
   Ratchet Adapter, Qty. 4
                                                                                      NP Ratchet Adapters                 Ratchet Extenders


Narrow Profile (NP)                           ●         Narrow design improves intra-oral access during implant placement.
                                              ●         Color anodized for easy identification of implant/placement head junction.
Placement Heads                               ●         External flats correspond to the flats of the implants internal hex for
                                                        easy indexing.

                                              Instrumentation Required:
                                              ❍         .048" Hex Driver
                                                                             SDI 3.75mm                         RDI 4.5/4.75mm
                                              Description                        Catalog No.                               Catalog No.
                                              3.5mm Placement Head               10585                                     10587
                                              5.5mm Placement Head               10586                                     10588
                                              15mm Placement Head                10579*                                    10580*


                                               * Call for availability
     For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300                                                     -29-
Direct-to-Implant      ●    Connects directly to RENOVA Tapered and Straight Implant prosthetic
                            connections for adjusting implant insertion depth during first stage surgery.
Ratchet Adapters       ●    Used in conjunction with the Surgical Ratchet.

                                               SDI 3.75mm                           RDI 4.5/4.75mm
                      Description                 Catalog No.                                Catalog No.
                      Adapter, short                10590                                    10592
                      Adapter, long                 10591                                    10593




 Stabilizing Wrench     ●
                        ●
                              For use only with Narrow Profile (NP) Placement Heads.
                              Use open or closed end to stabilize the implant during loosening of the
                              placement head screw.
                        ●     Features a special pin to engage the Ratchet Adapter (L1806-04) and
                              stabilize the implant during manual placement.
                              Description                                            Catalog No.
                              Stabilizing Wrench                                     L1709-01




Handpiece              ●     Inserts into the handpiece and connects to the RENOVA NP Placement
Placement Adapter            Head for motor driven implant placement.
                              Description                                             Catalog No.
                              Handpiece Adapter (for NP placement heads)              L1406-01




Hand Adapter for       ●    Connects to the RENOVA NP Placement Head and carries the implant to
                            the surgical site for hand delivered implant placement.
Narrow Profile (NP)    ●    Can also be used to remove the placement head by inserting a hex
Placement Head              driver through the top end to loosen the screw and then carry the
                            placement head assembly out of the mouth.

                            Description                                             Catalog No.
                            Hand Adapter (for NP placement heads)                   L1406-02




-30-                                For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300
Titanium Forceps                              ●    Titanium Forceps are used to handle implants and other titanium
                                                   components to avoid possible contamination.

                                                   Description                                  Catalog No.
                                                   Titanium Forceps                             R9119




Locking Drill Extender                        ●    Adds 17mm of length to any latch-type drill or driver.
                                              ●    Useful when drilling next to adjacent teeth.

                                                   Description                                  Catalog No.
                                                   Locking Drill Extender                       L1404-01




Implant Sizing Overlays
                                              ●    Use these transparent overlays with radiographs for pre-surgical
                                                   assessment and implant selection.
                                              ●    100% (1:1) Sizing Overlay for use with peri-apical x-rays.
                                              ●    125% Sizing Overlay for panoramic radiographs.




                                                                                                                                   Instrumentation & Motor
                                                   Description                                                Catalog No.
                                                   Tapered Implant 100% (1:1) Sizing Overlay                  14050*
                                                   Tapered Implant 125% Sizing Overlay                        14051*
                                                   Straight Implant 100% (1:1) Sizing Overlay                 13027*
                                                   Straight Implant 125% Sizing Overlay                       13028*

                                           * Call for availability




   For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300                                     -31-
Wrenches and Drivers

 Accu-Torque Wrenches & Accessories
                                                                                                                                20Ncm Torque Wrench
 ●     Pre-calibrated wrenches precisely deliver proper torque.
 ●     Use with Accu-Torque Drivers.
 ●     Conversion Handle allows use of Accu-Torque Drivers as hand drivers.                                                     30Ncm Torque Wrench


    Description                                                                   Catalog No.
    Accu-Torque Wrench, 20Ncm                                                       ISS1101
    Accu-Torque Wrench, 30Ncm                                                       ISS1102
                                                                                                                                Conversion Handle for
    Conversion Handle for Accu-Torque Drivers, Swivel Head                          ISS1112                                      Accu-Torque Drivers
    Replacement O-Rings for Accu-Torque Drivers, Qty 6                              ISS1111




Torque Wrench Care and Maintenance
Cleaning and Sterilization:
●    Before initial use and after each procedure, clean the torque wrench with a wet towel or disinfectant wipe.
     Rinse under warm tap water and wipe dry.
●    Before sterilization, spray an approved (handpiece type) instrument lubricant into the opening at the back of
     the wrench.
●    Sterilize with the handle in the broken position.
●    Wrench may be sterilized by steam autoclave. Do not exceed 125°C (257°F).
●    Always use the dry cycle.
●    Do not use “Flash Sterilization” techniques.
●    After sterilization, reset the torque break handle, then manually “break” the hinge again to ensure the wrench is
     operating correctly.

Calibration:
For proper function and accurate control, Accu-Torque Wrenches should be calibrated every 6 months (or after 100
autoclave cycles). For calibration or repair, wrenches should be sent directly to:

Micromotor Repair Station
151 East Columbine Avenue
Santa Ana, CA 92707 USA
800-562-6204
Outside the U.S.: 714-546-4045

* For Lifecore’s Torque Wrench warranty information, please reference the Ordering & Warranty Information section on page 37.




-32-                                                               For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300
.048" Hex Drivers                      ●     Use with .048" hex placement head screws, healing abutments,
                                             abutment screws and impression posts.
                                       ●     Tapered hex tip allows screws to be carried to the implant site.


                                           Description                                                          Catalog No.
                                           .048" Hex Driver, Swivel Head, Short (8mm shaft/19mm total length)   R9121
                                           .048" Hex Driver, Swivel Head, Long (13mm shaft/24mm total length)   R9122

                                           .048" Hex Driver, Latch-Type, Short (23mm total length)              L1400-48-23
       Hex     Latch Type   Accu-          .048" Hex Driver, Latch-Type, Long (28mm total length)               L1400-48-28
      Driver     Driver     Torque
                            Driver         .048" Hex Driver, for Accu-Torque Wrench, Short (8mm shaft)          ISS1104
                                           .048" Hex Driver, for Accu-Torque Wrench, Long (15mm shaft)          ISS1109



.062" Hex Drivers                      ●     Used for Fixed Detachable Abutments.
                                       ●     Tapered hex tip allows abutments to be carried to the implant site.

                                          Description                                                           Catalog No.
                                          .062" Hex Driver, Swivel Head, Short (8mm shaft/19mm total length)    L2100-62-19
                                          .062" Hex Driver, Swivel Head, Long (13mm shaft/24mm total length)    L2100-62-24

                                          .062" Hex Driver, Latch-Type, Short (23mm total length)               L1400-62-19
                                          .062" Hex Driver, Latch-Type, Long (28mm total length)                L1400-62-23




                                                                                                                                     Instrumentation & Motor
      Swivel    Latch- Accu-
      Head       Type Torque
      Driver    Driver Driver             .062" Hex Driver, for Accu-Torque Wrench, Short (8mm shaft)           ISS1119
                                          .062" Hex Driver, for Accu-Torque Wrench, Long (15mm shaft)           ISS1120




Overdenture
                                       ●     Used for Snap Abutments.
Abutment Drivers

                                           Description                                                          Catalog No.
                                           Overdenture Driver, Swivel Head (8mm shaft)                          L2100-96-19

                                           Overdenture Driver, Latch-Type (20mm total length)                   L1404-96-20

                                           Overdenture Driver, for Accu-Torque Wrench* (8mm shaft)              L2101-96-16
      Swivel     Latch      Accu-
      Head       Type       Torque
      Driver     Driver     Driver




  For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300                                        -33-
Lab Tools & Other Products

  Hader Bar and Clip System
  ●      A simple, effective bar system, featuring a plastic bar pattern and
         nylon clips, which are processed into the removable prosthesis.
  ●      Mechanical snap retention.




                   Hader Castable Bar


                                        Description                                                                    Catalog No.
     Hader                              Hader Castable Bar And Clip System                                             ISS185H
 Processing Clip                                                                                                       (includes 1 Hader Bar, 6
                                        Processing Clips, 6 Final Clips & 1 Hader Tool)
     Hader                              Hader Castable Bar                                                             ISS185B
   Final Clip
                                        Hader Processing Clips, Qty. 6                                                 ISS185HP
                                        Hader Final Clips, Qty. 6                                                      ISS185HR

  Hader Metal                           Hader Clip Metal Housings, Qty. 6                                              ISS526H
  Housing Clip
                                        Hader Tool                                                                     ISS185T

                      Hader Tool




-34-                                                     For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300
Component Pack                              ●    Organizes small components such as the implant cover screws,
                                                 placement heads, etc.
                                            ●    Autoclavable design with slide lid interlocks into the base of the
                                                 surgical kits.
                                            ●    Optionally, may be used as a stand-alone organizer.



                                          Description                                         Catalog No.
                                          Component Pack                                       L1812-01




  Instrument Cleaning Detergent
  • For use with all Lifecore instruments and surgical kits.
  • Includes recommended cleaning instructions.
  Cleaning Detergent                                           L1819-01




                                                                                                                             Instrumentation & Motor




      For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300                            -35-
LC5000 Surgical Motor System
 LC5000 Features:
 Lifecore’s LC5000 is a
 simple, user-friendly motor
 with abundant features for
 implantology and oral and
 maxillofacial microsurgery.
 Carefully designed features,
 place the LC5000 in a class
 of its own. The unique
 motor with large on-screen
 graphics display, straight-
 forward console layout, foot
 pedal control and
 Program/Patient Information
 Smart Cards exemplifies
 high performance.

 Since the LC5000 is manufactured specifically for Lifecore Biomedical, it comes complete with Lifecore’s
 surgical protocol preprogrammed and is backed by a full one-year warranty. In addition, the compact design
 helps maximize surgical work area.

 ●     Compact design helps maximize surgical work area

 ●     Large, easy-to-read display clearly identifies motor settings including procedure, rpm, torque, irrigation flow rate, etc.

 ●     Unique foot pedal design with large buttons simplifies access to functions during surgery.
       Also provides variable speed control.

 ●     A versatile 20:1 handpiece can be used for drilling, tapping and implant placement (sold separately).

 ●     Torque Bar display provides a visual reference of torque delivered during procedures.
 ●     Program Data Smart Card instantly saves/retrieves up to 20 custom program settings.

 ●     Patient Data Smart Card & PC Software stores patient information for documenting patient treatment data.

 ●     Auto-Calibration function for motor/handpiece enables superior rpm and torque control.

 ●     Full one-year warranty included. Extended warranty options also available. Contact Lifecore Client Service or your
       sales representative for more details.

Lifecore LC5000 Surgical Motor System Package
Description                                                                                 Catalog #
LC5000 Surgical Motor and Console                                                           10594
20:1 Handpiece                                                                              10595
10-pack of Sterile Irrigation Tubing                                                        10598
Testing Gauge for Latch-Type Instrument Shanks                                              10602
PC Software Updating Kit                                                                    10611
Service Oil, 50ml*                                                                          10604

-36-                                                For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300
Lifecore LC5000 Surgical Motor Accessories
Description                                                                                             Catalog #
LC5000 Surgical Motor Unit                                                                              10594
20:1 Reduction Contra-Angle Handpiece - for implant surgery
(up to 150,000 rpm when used with LC5000 Motor)                                                         10595
1:1 High Speed Straight Handpiece
(up to 30,000 rpm when used with LC5000 Motor)                                                          10596
1:5 High Speed Straight Handpiece
(up to 30,000 rpm when used with LC5000 Motor)                                                          10597
Irrigation Tubing, Sterile, 10-pack                                                                     10598
Irrigation Needle, 2-pack                                                                               10599
Y-Connector, 2-pack                                                                                     10600
Y-Tubing, 2-pack                                                                                        10601
Testing Gauge (for latch-type instrument shanks)                                                        10602
Travel Case (for LC5000 Motor System)                                                                   10603
Service Oil, 50ml*                                                                                      10604
Service Oil, 250ml (6-pack)*                                                                            10613




                                                                                                                                       Instrumentation & Motor
Sterilization Protector for Motor                                                                       10607
Sterilization Case                                                                                      10606
Patient Data Smart Card, 1-pack (for LC5000)                                                            10608
Program Data Smart Card, 1-pack (for LC5000)                                                            10609
System Software Card, 1-pack (for LC5000)                                                               10610
PC Software Updating Kit                                                                                10611
USB Cable Adapter                                                                                       10612

*Due to aerosol service oil can, special shipping and handling is required. Please contact Client Service for shipping rates.




       For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300                                     -37-
Tissue Regeneration Products


                                                                                                                               ®


       CAPSET Calcium Sulfate Bone Graft Barrier
       CAPSET Calcium Sulfate Bone Graft Barrier is a barrier designed to be used over bone
       grafting material to aid bone regeneration. Each CAPSET kit contains proprietary
       formulation calcium sulfate and an accelerating solution. When mixed together,
       they form a paste, which is molded into place over bone grafting material.


       CAPSET Features:
       • Bioresorbable
       • Conforms to Defect
       • Easy to Use
       • Positive Tissue Response
       • Offers Longer Working Time (SlowSet)
       • Ideal for Multiple Defects (SlowSet)


       The 0.25gm reserve cup of calcium sulfate can act as a binder when mixed with
       Bone Allograft, Autogenous Bone, Xenografts or Synthetic Bone grafting material.
       • Improves handling properties             • Reduces particle migration



        Description                                             Catalog #
        CAPSET 1.0gm                                             4061-10
        CAPSET 2.0gm                                             4061-20
        CAPSET SlowSet 1.0gm                                     4064-10
        CAPSET SlowSet 2.0gm                                     4064-20
        0.25gm Reserve Cup, 6-Pack                               4061-025




-38-                                          For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300
Lifecore implant
Lifecore implant
Lifecore implant
Lifecore implant
Lifecore implant

Contenu connexe

Tendances

Surgical implant placement guides/prosthodontic courses
Surgical implant placement guides/prosthodontic coursesSurgical implant placement guides/prosthodontic courses
Surgical implant placement guides/prosthodontic coursesIndian dental academy
 
Implant splinting with natural tooth
Implant splinting with natural toothImplant splinting with natural tooth
Implant splinting with natural toothYamen Nouh
 
Journal club presentation on tooth supported overdentures
Journal club presentation on tooth supported overdentures Journal club presentation on tooth supported overdentures
Journal club presentation on tooth supported overdentures NAMITHA ANAND
 
JOURNAL CLUB on bio materials in implants
JOURNAL CLUB on bio materials in implantsJOURNAL CLUB on bio materials in implants
JOURNAL CLUB on bio materials in implantsDr. Vijaya Lakshmi
 
Implant prosthetic dentistry
Implant prosthetic dentistryImplant prosthetic dentistry
Implant prosthetic dentistryRuhi Kashmiri
 
5- OVERDENTURE.pptx
5- OVERDENTURE.pptx5- OVERDENTURE.pptx
5- OVERDENTURE.pptxAmalKaddah1
 
Post & core /certified fixed orthodontic courses by Indian dental academy
Post & core  /certified fixed orthodontic courses by Indian dental academy Post & core  /certified fixed orthodontic courses by Indian dental academy
Post & core /certified fixed orthodontic courses by Indian dental academy Indian dental academy
 
Occulasl consideration for implant supported prostehsi/dental courses
Occulasl consideration for implant supported prostehsi/dental coursesOcculasl consideration for implant supported prostehsi/dental courses
Occulasl consideration for implant supported prostehsi/dental coursesIndian dental academy
 
PROGRESSIVE LOADING IN IMPLANTS
PROGRESSIVE LOADING IN IMPLANTSPROGRESSIVE LOADING IN IMPLANTS
PROGRESSIVE LOADING IN IMPLANTSshari kurup
 
Attachments in removable partial prosthesis
Attachments in removable partial prosthesisAttachments in removable partial prosthesis
Attachments in removable partial prosthesishamide norouzi
 
Implant abutment and implant abutment connections
Implant abutment and implant abutment connectionsImplant abutment and implant abutment connections
Implant abutment and implant abutment connectionsDR.BHAVESH JHA
 
Complications failures and maintainence of dental implant
Complications failures and maintainence of dental implantComplications failures and maintainence of dental implant
Complications failures and maintainence of dental implantRasleen87
 
Preventive prosthodontics
Preventive prosthodonticsPreventive prosthodontics
Preventive prosthodontics04842698028
 
Classification and impression techniques of implants/ dentistry dental implants
Classification and impression techniques of implants/ dentistry dental implantsClassification and impression techniques of implants/ dentistry dental implants
Classification and impression techniques of implants/ dentistry dental implantsIndian dental academy
 
TOOTH SUPPORTED OVERDENTURES
 TOOTH SUPPORTED OVERDENTURES TOOTH SUPPORTED OVERDENTURES
TOOTH SUPPORTED OVERDENTURESsneha106
 

Tendances (20)

Surgical implant placement guides/prosthodontic courses
Surgical implant placement guides/prosthodontic coursesSurgical implant placement guides/prosthodontic courses
Surgical implant placement guides/prosthodontic courses
 
implantology
  implantology  implantology
implantology
 
Implant splinting with natural tooth
Implant splinting with natural toothImplant splinting with natural tooth
Implant splinting with natural tooth
 
Implant components and basic techniques3
Implant components and basic techniques3Implant components and basic techniques3
Implant components and basic techniques3
 
Journal club presentation on tooth supported overdentures
Journal club presentation on tooth supported overdentures Journal club presentation on tooth supported overdentures
Journal club presentation on tooth supported overdentures
 
JOURNAL CLUB on bio materials in implants
JOURNAL CLUB on bio materials in implantsJOURNAL CLUB on bio materials in implants
JOURNAL CLUB on bio materials in implants
 
Implant prosthetic dentistry
Implant prosthetic dentistryImplant prosthetic dentistry
Implant prosthetic dentistry
 
5- OVERDENTURE.pptx
5- OVERDENTURE.pptx5- OVERDENTURE.pptx
5- OVERDENTURE.pptx
 
Post & core /certified fixed orthodontic courses by Indian dental academy
Post & core  /certified fixed orthodontic courses by Indian dental academy Post & core  /certified fixed orthodontic courses by Indian dental academy
Post & core /certified fixed orthodontic courses by Indian dental academy
 
Implant occlusion
 Implant occlusion Implant occlusion
Implant occlusion
 
Occulasl consideration for implant supported prostehsi/dental courses
Occulasl consideration for implant supported prostehsi/dental coursesOcculasl consideration for implant supported prostehsi/dental courses
Occulasl consideration for implant supported prostehsi/dental courses
 
PROGRESSIVE LOADING IN IMPLANTS
PROGRESSIVE LOADING IN IMPLANTSPROGRESSIVE LOADING IN IMPLANTS
PROGRESSIVE LOADING IN IMPLANTS
 
Attachments in removable partial prosthesis
Attachments in removable partial prosthesisAttachments in removable partial prosthesis
Attachments in removable partial prosthesis
 
Implant abutment and implant abutment connections
Implant abutment and implant abutment connectionsImplant abutment and implant abutment connections
Implant abutment and implant abutment connections
 
Complications failures and maintainence of dental implant
Complications failures and maintainence of dental implantComplications failures and maintainence of dental implant
Complications failures and maintainence of dental implant
 
Preventive prosthodontics
Preventive prosthodonticsPreventive prosthodontics
Preventive prosthodontics
 
Implant Occlusion.pptx
Implant Occlusion.pptxImplant Occlusion.pptx
Implant Occlusion.pptx
 
Dental implants by Bhaskar Dewangan
Dental implants by Bhaskar DewanganDental implants by Bhaskar Dewangan
Dental implants by Bhaskar Dewangan
 
Classification and impression techniques of implants/ dentistry dental implants
Classification and impression techniques of implants/ dentistry dental implantsClassification and impression techniques of implants/ dentistry dental implants
Classification and impression techniques of implants/ dentistry dental implants
 
TOOTH SUPPORTED OVERDENTURES
 TOOTH SUPPORTED OVERDENTURES TOOTH SUPPORTED OVERDENTURES
TOOTH SUPPORTED OVERDENTURES
 

Similaire à Lifecore implant

Spinal fixation systems spine implants spine company
Spinal fixation systems  spine implants  spine companySpinal fixation systems  spine implants  spine company
Spinal fixation systems spine implants spine companyBacklink Paketleri
 
Neovasc Surgical Division
Neovasc Surgical DivisionNeovasc Surgical Division
Neovasc Surgical DivisionRandy_Lane
 
Esco Versati Laboratory Centrifuge
Esco Versati Laboratory CentrifugeEsco Versati Laboratory Centrifuge
Esco Versati Laboratory CentrifugeEsco Group
 
Esco Biological Safety Cabinet Catalog
Esco Biological Safety Cabinet CatalogEsco Biological Safety Cabinet Catalog
Esco Biological Safety Cabinet CatalogEsco Group
 
Esco Laminar Flow Clean Bench
Esco Laminar Flow Clean BenchEsco Laminar Flow Clean Bench
Esco Laminar Flow Clean BenchEsco Group
 
OMICRON Testing Solutions For Protection & Measurement Systems - OMICRON CMC ...
OMICRON Testing Solutions For Protection & Measurement Systems - OMICRON CMC ...OMICRON Testing Solutions For Protection & Measurement Systems - OMICRON CMC ...
OMICRON Testing Solutions For Protection & Measurement Systems - OMICRON CMC ...Thorne & Derrick International
 
Medvantage Tech Overview
Medvantage Tech OverviewMedvantage Tech Overview
Medvantage Tech Overviewezitizer
 
HalcyonOrthopedics_UCR_BMEStart-1
HalcyonOrthopedics_UCR_BMEStart-1HalcyonOrthopedics_UCR_BMEStart-1
HalcyonOrthopedics_UCR_BMEStart-1Afshin Mostaghim
 
Omicron Testing Solutions for Protection and Measurement Systems - Datasheet ...
Omicron Testing Solutions for Protection and Measurement Systems - Datasheet ...Omicron Testing Solutions for Protection and Measurement Systems - Datasheet ...
Omicron Testing Solutions for Protection and Measurement Systems - Datasheet ...Angus Sankaran
 
S 4 - CVC-Self-Learning-Package-v9-June-2018-FINAL.pdf
S 4 - CVC-Self-Learning-Package-v9-June-2018-FINAL.pdfS 4 - CVC-Self-Learning-Package-v9-June-2018-FINAL.pdf
S 4 - CVC-Self-Learning-Package-v9-June-2018-FINAL.pdfgurl7
 
Suture types & comparison training ppt.
Suture types & comparison training ppt.Suture types & comparison training ppt.
Suture types & comparison training ppt.Deepak Mudgil
 
Catalog Resista 2019
Catalog Resista 2019Catalog Resista 2019
Catalog Resista 2019terradent
 
Esco CO2 Incubator Combined Catalog
Esco CO2 Incubator Combined CatalogEsco CO2 Incubator Combined Catalog
Esco CO2 Incubator Combined CatalogEsco Group
 
Hip Replacement Stem Cell Coating Business Plan-Hipsters R Us
Hip Replacement Stem Cell Coating Business Plan-Hipsters R UsHip Replacement Stem Cell Coating Business Plan-Hipsters R Us
Hip Replacement Stem Cell Coating Business Plan-Hipsters R UsSagar Desai
 
Solutions that Integrate – BioCompatic: A Robust USP Class VI Silicone Altern...
Solutions that Integrate – BioCompatic: A Robust USP Class VI Silicone Altern...Solutions that Integrate – BioCompatic: A Robust USP Class VI Silicone Altern...
Solutions that Integrate – BioCompatic: A Robust USP Class VI Silicone Altern...NorthwireCable
 
Corporate Brochure
Corporate BrochureCorporate Brochure
Corporate Brochureruudfrissen
 

Similaire à Lifecore implant (20)

Spinal fixation systems spine implants spine company
Spinal fixation systems  spine implants  spine companySpinal fixation systems  spine implants  spine company
Spinal fixation systems spine implants spine company
 
Neovasc Surgical Division
Neovasc Surgical DivisionNeovasc Surgical Division
Neovasc Surgical Division
 
Esco Versati Laboratory Centrifuge
Esco Versati Laboratory CentrifugeEsco Versati Laboratory Centrifuge
Esco Versati Laboratory Centrifuge
 
Esco Biological Safety Cabinet Catalog
Esco Biological Safety Cabinet CatalogEsco Biological Safety Cabinet Catalog
Esco Biological Safety Cabinet Catalog
 
Esco Laminar Flow Clean Bench
Esco Laminar Flow Clean BenchEsco Laminar Flow Clean Bench
Esco Laminar Flow Clean Bench
 
OMICRON Testing Solutions For Protection & Measurement Systems - OMICRON CMC ...
OMICRON Testing Solutions For Protection & Measurement Systems - OMICRON CMC ...OMICRON Testing Solutions For Protection & Measurement Systems - OMICRON CMC ...
OMICRON Testing Solutions For Protection & Measurement Systems - OMICRON CMC ...
 
Medvantage Tech Overview
Medvantage Tech OverviewMedvantage Tech Overview
Medvantage Tech Overview
 
HalcyonOrthopedics_UCR_BMEStart-1
HalcyonOrthopedics_UCR_BMEStart-1HalcyonOrthopedics_UCR_BMEStart-1
HalcyonOrthopedics_UCR_BMEStart-1
 
Omicron Testing Solutions for Protection and Measurement Systems - Datasheet ...
Omicron Testing Solutions for Protection and Measurement Systems - Datasheet ...Omicron Testing Solutions for Protection and Measurement Systems - Datasheet ...
Omicron Testing Solutions for Protection and Measurement Systems - Datasheet ...
 
2011 Lion Catalog
2011 Lion Catalog2011 Lion Catalog
2011 Lion Catalog
 
Bonetech Profile
Bonetech ProfileBonetech Profile
Bonetech Profile
 
S 4 - CVC-Self-Learning-Package-v9-June-2018-FINAL.pdf
S 4 - CVC-Self-Learning-Package-v9-June-2018-FINAL.pdfS 4 - CVC-Self-Learning-Package-v9-June-2018-FINAL.pdf
S 4 - CVC-Self-Learning-Package-v9-June-2018-FINAL.pdf
 
CO2 Cell Culture Incubators
CO2 Cell Culture IncubatorsCO2 Cell Culture Incubators
CO2 Cell Culture Incubators
 
Suture types & comparison training ppt.
Suture types & comparison training ppt.Suture types & comparison training ppt.
Suture types & comparison training ppt.
 
Catalog Resista 2019
Catalog Resista 2019Catalog Resista 2019
Catalog Resista 2019
 
Esco CO2 Incubator Combined Catalog
Esco CO2 Incubator Combined CatalogEsco CO2 Incubator Combined Catalog
Esco CO2 Incubator Combined Catalog
 
Loading of Two Implants in the
Loading of Two Implants in theLoading of Two Implants in the
Loading of Two Implants in the
 
Hip Replacement Stem Cell Coating Business Plan-Hipsters R Us
Hip Replacement Stem Cell Coating Business Plan-Hipsters R UsHip Replacement Stem Cell Coating Business Plan-Hipsters R Us
Hip Replacement Stem Cell Coating Business Plan-Hipsters R Us
 
Solutions that Integrate – BioCompatic: A Robust USP Class VI Silicone Altern...
Solutions that Integrate – BioCompatic: A Robust USP Class VI Silicone Altern...Solutions that Integrate – BioCompatic: A Robust USP Class VI Silicone Altern...
Solutions that Integrate – BioCompatic: A Robust USP Class VI Silicone Altern...
 
Corporate Brochure
Corporate BrochureCorporate Brochure
Corporate Brochure
 

Plus de Carlos Fernando Ruiz Laos

Plus de Carlos Fernando Ruiz Laos (6)

Terapeutica farmacologica anestesia - anatomia aplicada - cd carlos f ruiz ...
Terapeutica farmacologica   anestesia - anatomia aplicada - cd carlos f ruiz ...Terapeutica farmacologica   anestesia - anatomia aplicada - cd carlos f ruiz ...
Terapeutica farmacologica anestesia - anatomia aplicada - cd carlos f ruiz ...
 
Reborde alveolar conservacion y manejo en implantes
Reborde alveolar conservacion y manejo en implantesReborde alveolar conservacion y manejo en implantes
Reborde alveolar conservacion y manejo en implantes
 
Implantes lifecore
Implantes lifecoreImplantes lifecore
Implantes lifecore
 
Tumores odontogenicos
Tumores odontogenicosTumores odontogenicos
Tumores odontogenicos
 
Clasificación de la enfermedad periodontal
Clasificación de la enfermedad periodontalClasificación de la enfermedad periodontal
Clasificación de la enfermedad periodontal
 
Importancia De Su Plan Dental
Importancia De Su Plan DentalImportancia De Su Plan Dental
Importancia De Su Plan Dental
 

Dernier

The Most Excellent Way | 1 Corinthians 13
The Most Excellent Way | 1 Corinthians 13The Most Excellent Way | 1 Corinthians 13
The Most Excellent Way | 1 Corinthians 13Steve Thomason
 
Mastering the Unannounced Regulatory Inspection
Mastering the Unannounced Regulatory InspectionMastering the Unannounced Regulatory Inspection
Mastering the Unannounced Regulatory InspectionSafetyChain Software
 
Solving Puzzles Benefits Everyone (English).pptx
Solving Puzzles Benefits Everyone (English).pptxSolving Puzzles Benefits Everyone (English).pptx
Solving Puzzles Benefits Everyone (English).pptxOH TEIK BIN
 
Presiding Officer Training module 2024 lok sabha elections
Presiding Officer Training module 2024 lok sabha electionsPresiding Officer Training module 2024 lok sabha elections
Presiding Officer Training module 2024 lok sabha electionsanshu789521
 
Introduction to AI in Higher Education_draft.pptx
Introduction to AI in Higher Education_draft.pptxIntroduction to AI in Higher Education_draft.pptx
Introduction to AI in Higher Education_draft.pptxpboyjonauth
 
Micromeritics - Fundamental and Derived Properties of Powders
Micromeritics - Fundamental and Derived Properties of PowdersMicromeritics - Fundamental and Derived Properties of Powders
Micromeritics - Fundamental and Derived Properties of PowdersChitralekhaTherkar
 
A Critique of the Proposed National Education Policy Reform
A Critique of the Proposed National Education Policy ReformA Critique of the Proposed National Education Policy Reform
A Critique of the Proposed National Education Policy ReformChameera Dedduwage
 
Presentation by Andreas Schleicher Tackling the School Absenteeism Crisis 30 ...
Presentation by Andreas Schleicher Tackling the School Absenteeism Crisis 30 ...Presentation by Andreas Schleicher Tackling the School Absenteeism Crisis 30 ...
Presentation by Andreas Schleicher Tackling the School Absenteeism Crisis 30 ...EduSkills OECD
 
Incoming and Outgoing Shipments in 1 STEP Using Odoo 17
Incoming and Outgoing Shipments in 1 STEP Using Odoo 17Incoming and Outgoing Shipments in 1 STEP Using Odoo 17
Incoming and Outgoing Shipments in 1 STEP Using Odoo 17Celine George
 
How to Make a Pirate ship Primary Education.pptx
How to Make a Pirate ship Primary Education.pptxHow to Make a Pirate ship Primary Education.pptx
How to Make a Pirate ship Primary Education.pptxmanuelaromero2013
 
Industrial Policy - 1948, 1956, 1973, 1977, 1980, 1991
Industrial Policy - 1948, 1956, 1973, 1977, 1980, 1991Industrial Policy - 1948, 1956, 1973, 1977, 1980, 1991
Industrial Policy - 1948, 1956, 1973, 1977, 1980, 1991RKavithamani
 
microwave assisted reaction. General introduction
microwave assisted reaction. General introductionmicrowave assisted reaction. General introduction
microwave assisted reaction. General introductionMaksud Ahmed
 
URLs and Routing in the Odoo 17 Website App
URLs and Routing in the Odoo 17 Website AppURLs and Routing in the Odoo 17 Website App
URLs and Routing in the Odoo 17 Website AppCeline George
 
Arihant handbook biology for class 11 .pdf
Arihant handbook biology for class 11 .pdfArihant handbook biology for class 11 .pdf
Arihant handbook biology for class 11 .pdfchloefrazer622
 
Hybridoma Technology ( Production , Purification , and Application )
Hybridoma Technology  ( Production , Purification , and Application  ) Hybridoma Technology  ( Production , Purification , and Application  )
Hybridoma Technology ( Production , Purification , and Application ) Sakshi Ghasle
 
Paris 2024 Olympic Geographies - an activity
Paris 2024 Olympic Geographies - an activityParis 2024 Olympic Geographies - an activity
Paris 2024 Olympic Geographies - an activityGeoBlogs
 
Sanyam Choudhary Chemistry practical.pdf
Sanyam Choudhary Chemistry practical.pdfSanyam Choudhary Chemistry practical.pdf
Sanyam Choudhary Chemistry practical.pdfsanyamsingh5019
 
mini mental status format.docx
mini    mental       status     format.docxmini    mental       status     format.docx
mini mental status format.docxPoojaSen20
 
Separation of Lanthanides/ Lanthanides and Actinides
Separation of Lanthanides/ Lanthanides and ActinidesSeparation of Lanthanides/ Lanthanides and Actinides
Separation of Lanthanides/ Lanthanides and ActinidesFatimaKhan178732
 

Dernier (20)

The Most Excellent Way | 1 Corinthians 13
The Most Excellent Way | 1 Corinthians 13The Most Excellent Way | 1 Corinthians 13
The Most Excellent Way | 1 Corinthians 13
 
Mastering the Unannounced Regulatory Inspection
Mastering the Unannounced Regulatory InspectionMastering the Unannounced Regulatory Inspection
Mastering the Unannounced Regulatory Inspection
 
Solving Puzzles Benefits Everyone (English).pptx
Solving Puzzles Benefits Everyone (English).pptxSolving Puzzles Benefits Everyone (English).pptx
Solving Puzzles Benefits Everyone (English).pptx
 
Presiding Officer Training module 2024 lok sabha elections
Presiding Officer Training module 2024 lok sabha electionsPresiding Officer Training module 2024 lok sabha elections
Presiding Officer Training module 2024 lok sabha elections
 
Introduction to AI in Higher Education_draft.pptx
Introduction to AI in Higher Education_draft.pptxIntroduction to AI in Higher Education_draft.pptx
Introduction to AI in Higher Education_draft.pptx
 
Micromeritics - Fundamental and Derived Properties of Powders
Micromeritics - Fundamental and Derived Properties of PowdersMicromeritics - Fundamental and Derived Properties of Powders
Micromeritics - Fundamental and Derived Properties of Powders
 
A Critique of the Proposed National Education Policy Reform
A Critique of the Proposed National Education Policy ReformA Critique of the Proposed National Education Policy Reform
A Critique of the Proposed National Education Policy Reform
 
Presentation by Andreas Schleicher Tackling the School Absenteeism Crisis 30 ...
Presentation by Andreas Schleicher Tackling the School Absenteeism Crisis 30 ...Presentation by Andreas Schleicher Tackling the School Absenteeism Crisis 30 ...
Presentation by Andreas Schleicher Tackling the School Absenteeism Crisis 30 ...
 
Incoming and Outgoing Shipments in 1 STEP Using Odoo 17
Incoming and Outgoing Shipments in 1 STEP Using Odoo 17Incoming and Outgoing Shipments in 1 STEP Using Odoo 17
Incoming and Outgoing Shipments in 1 STEP Using Odoo 17
 
How to Make a Pirate ship Primary Education.pptx
How to Make a Pirate ship Primary Education.pptxHow to Make a Pirate ship Primary Education.pptx
How to Make a Pirate ship Primary Education.pptx
 
Industrial Policy - 1948, 1956, 1973, 1977, 1980, 1991
Industrial Policy - 1948, 1956, 1973, 1977, 1980, 1991Industrial Policy - 1948, 1956, 1973, 1977, 1980, 1991
Industrial Policy - 1948, 1956, 1973, 1977, 1980, 1991
 
microwave assisted reaction. General introduction
microwave assisted reaction. General introductionmicrowave assisted reaction. General introduction
microwave assisted reaction. General introduction
 
Código Creativo y Arte de Software | Unidad 1
Código Creativo y Arte de Software | Unidad 1Código Creativo y Arte de Software | Unidad 1
Código Creativo y Arte de Software | Unidad 1
 
URLs and Routing in the Odoo 17 Website App
URLs and Routing in the Odoo 17 Website AppURLs and Routing in the Odoo 17 Website App
URLs and Routing in the Odoo 17 Website App
 
Arihant handbook biology for class 11 .pdf
Arihant handbook biology for class 11 .pdfArihant handbook biology for class 11 .pdf
Arihant handbook biology for class 11 .pdf
 
Hybridoma Technology ( Production , Purification , and Application )
Hybridoma Technology  ( Production , Purification , and Application  ) Hybridoma Technology  ( Production , Purification , and Application  )
Hybridoma Technology ( Production , Purification , and Application )
 
Paris 2024 Olympic Geographies - an activity
Paris 2024 Olympic Geographies - an activityParis 2024 Olympic Geographies - an activity
Paris 2024 Olympic Geographies - an activity
 
Sanyam Choudhary Chemistry practical.pdf
Sanyam Choudhary Chemistry practical.pdfSanyam Choudhary Chemistry practical.pdf
Sanyam Choudhary Chemistry practical.pdf
 
mini mental status format.docx
mini    mental       status     format.docxmini    mental       status     format.docx
mini mental status format.docx
 
Separation of Lanthanides/ Lanthanides and Actinides
Separation of Lanthanides/ Lanthanides and ActinidesSeparation of Lanthanides/ Lanthanides and Actinides
Separation of Lanthanides/ Lanthanides and Actinides
 

Lifecore implant

  • 1. Lifecore RENOVA ™ Internal Hex Implant System Surgical & Restorative Catalog
  • 2. Table of Contents Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 RENOVA Implant System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-5 RENOVA Drill Sequence Charts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-7 RENOVA Implants RENOVA Tapered Implants . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 RENOVA Straight Implants . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Cover Screws & Healing Abutments . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Cement-Retained Restorations Cement-on-Crown (COC) Abutment System. . . . . . . . . . . . . . . . . . . . 11-13 Screw-Retained Restorations UCLA Abutment System. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14-16 Fixed Detachable Abutment System. . . . . . . . . . . . . . . . . . . . . . . . . . 17-19 Overdenture Restorations Snap Abutment System. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20-22 Surgical Kit for RENOVA Tapered Implants . . . . . . . . . . . . . . . . . . . . . . . . . 23 Surgical Instrumentation for RENOVA Tapered Implants . . . . . . . . . . . . 24-25 Surgical Kit for RENOVA Straight Implants. . . . . . . . . . . . . . . . . . . . . . . . . . 26 Surgical Instrumentation for RENOVA Straight Implants. . . . . . . . . . . . . 27-28 Additional Surgical Instrumentation for Tapered & Straight Implants . . . 29-31 Surgical Wrenches and Drivers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32-33 Lab Tools and Other Products . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34-35 Lifecore LC5000 Surgical Motor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36-37 Tissue Regeneration Products Capset® Calcium Sulfate Bone Graft Barrier. . . . . . . . . . . . . . . . . . . . . . . 38 TefGen® Regenerative Membranes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 Warranty Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 Order Form . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 -2- For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300
  • 3. Introduction A Leader in Biotechnology … Lifecore Biomedical is dedicated to the development of technologically advanced, dependable products that offer long-term compatibility with the human body. Thousands of patients worldwide have benefited from Lifecore’s technology in dentistry, general surgery and ophthalmology. Founded in 1965, Lifecore is a publicly held company (Nasdaq: LCBM) headquartered in Chaska, Minnesota, USA. Lifecore’s Oral Restorative Division is focused on providing the highest quality surgical devices and applications for the global dental industry. The Division offers one of the most extensive product lines to address the many clinical situations faced by our clients. Lifecore offers two-stage internal and external hex implant systems and a single stage implant system. A complete family of restorative options are available to meet the unique needs of each patient. Visit us at www.lifecore.com to learn more. Our Commitment to Quality … Lifecore’s commitment to quality and service ensures that our products meet or exceed the highest standards set by the United States Food and Drug Administration, the European Community and other international agencies. Lifecore has earned ISO 9001 and CE Certifications, international symbols of quality system assurance and compliance. Lifecore has earned a reputation for quality by enforcing strict design and inspection criteria. Our 100% inspection of all critical dimensions of dental implants and prosthetic components has allowed Lifecore to maintain the tightest tolerances in the industry. In addition, Lifecore’s Lifetime Limited Warranty gives the clinician the added security of knowing that dental implants and prosthetics are covered throughout the patient’s lifetime. Our Commitment to Your Practice … Lifecore’s technical services department is available to consult with clients on questions related to case planning, component selection and step-by-step procedures for clinical and laboratory applications. Our family of Support Plus® Restorative Training Programs are recognized in the industry as the best referral based training courses available. Lifecore is certified through the Academy of General Dentistry, the American Dental Association and through the National Board of Certification to offer continuing education credits. Lifecore is committed to being the standard of comparison for product quality, education and customer service, and to be recognized as a company of dedication, honesty and integrity. For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300 -3-
  • 4. RENOVA Implant System Internal hex prosthetic connection for superior esthetics and reliability 1mm machined titanium collar for soft tissue maintenance Parallel walled neck region with circumferential grooves for crestal seal and bone interlock Lifecore’s proven RBM Surface Straight and tapered designs expand treatment options Tapered design enables placement near impinging anatomical structures while STRAIGHT maximizing prosthetic table diameter for TAPERED natural emergence profile Apical end design provides excellent initial thread engagement and stability -4- For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300
  • 5. Internal Hex Prosthetic Connection Proven RBM Surface Delivers superior strength and ease Lifecore’s RENOVA, RESTORE® and STAGE-1™ of prosthetic indexability. implants feature the RBM surface. Lifecore’s RBM, a roughened titanium surface, has Beveled interface helps maximize been in clinical use since 1997 and has prosthetic stability and evenly achieved a high level of clinical acceptance. transfers occlusal forces to the implant. Lifecore’s RBM (Resorbable Blast Media) 2000X RBM Surface substantially increases bone-to-implant contact and mechanical bone interlock, with Deep internal hex connection approximately 250% more surface simplifies abutment seating and roughness than a machined titanium provides excellent tactile feel for surface. Safety and biological compatibility added confidence. are ensured through the exclusive use of biocompatible calcium phosphate ceramic RENOVA Prosthetics media in the roughening process. 500X RBM Surface The Tapered and Straight implant designs share the same prosthetics. As a clinician, you can have confidence in the Lifecore implant you choose knowing that Lifecore is an established leader in RBM surface technology. Our three implant designs, coupled with our The RENOVA system offers RBM surface technology, maximize your opportunity for clinical abutment systems for: flexibility and optimal treatment outcomes. • Cement-Retained restorations • Screw-Retained restorations Mechanical interlock of bone into the implant surface topography is evident. • Overdenture restorations A direct bone-to-implant interface is observed at 100x magnification.1 References: 1. Sanz A, et al. Experimental study of bone response to a new surface treatment of endosseous titanium implants. Implant Dentistry. 2001; 10:126-131. For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300 -5-
  • 6. Drill Sequence RENOVA Tapered Implants SDI 3.75mm RENOVA Tapered Implant 1 2 3 4 5 6 2.3mm Round Bur 2.0mm Initial Drill 3.75mm Intermediate Drill 3.75mm Finishing Drill 3.75mm Tap 3.75 x 13mm Implant RDI 4.5mm RENOVA Tapered Implant 1 2 3 4 5 6 2.3mm Round Bur 2.0mm Initial Drill 4.5mm Intermediate Drill 4.5mm Finishing Drill 4.5mm Tap 4.5 x 13mm Implant Depth Marking System (for Tapered Implants) 13mm NOTE: Drill stops and bands reference the insertion depth for the corresponding implant length. 0mm ≤0.36mm Initial Intermediate Finishing Tap Drill Drill Drill -6- For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300
  • 7. Drill Sequence Charts Drill Sequence RENOVA Straight Implants SDI 3.75mm RENOVA Straight Implant 1 2 3 4 5 6 7 8 9 2.3mm 2.0mm 2.35mm 2.35mm 2.8mm Drill 3.25mm Drill 3.75mm 3.75mm Tap 3.75 x 13mm Round Bur Initial Drill Drill Depth Gauge Countersink Drill Implant RDI 4.75mm RENOVA Straight Implant 1 2 3 4 5 6 7 8 9 10 11 2.3mm 2.0mm 2.35mm 2.35mm 2.8mm 3.25mm 3.25/4.25mm 4.25mm 4.75mm 4.75mm 4.75 x 13mm Round Bur Initial Drill Drill Depth Gauge Drill Drill Pilot Drill Drill Countersink Drill Tap Implant Depth Marking System (for Straight Implants) 16mm 13mm 11.5mm NOTE: Drill bands reference the insertion depth 10mm for the corresponding implant length and do not 8mm indicate actual millimeter drill length. 0mm ≤1.14mm 3.25x16mm 3.25x11.5mm Drill Drill For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300 -7-
  • 8. RENOVA Implants Lifecore RENOVA Tapered Implants Features: ● Tapered implant design. ● Lifecore RBM Surface. ● Cover Screw and pre-mounted, color-coded Placement Head (3.5mm) included with each implant. ● Packaged to minimize handling during placement. ● Gamma Sterilized. Instrumentation Required: ● RENOVA Tapered Implant Surgical Kit ● .048" Hex Driver for Placement Head and Cover Screw SDI 3.75mm RBM Tapered Implant Description Catalog No. 3.75mm 3.75 x 10mm 14000 3.75 x 11.5mm 14001 3.75 x 13mm 14002 length 3.75 x 14.5mm 14003 2.8mm Apical Diameter RDI 4.5mm RBM Tapered Implant Description Catalog No. 4.5mm 4.5 x 8.5mm 14004 4.5 x 10mm 14005 4.5 x 11.5mm 14006 4.5 x 13mm 14007 length 3.0mm Apical Diameter -8- For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300
  • 9. Lifecore RENOVA Straight Implants Features: ● Straight (parallel walled) implant design. ● Lifecore RBM Surface. Cover Screw and pre-mounted, color-coded Placement Head (3.5mm) included Healing Abutments ● with each implant. Implants & ● Packaged to minimize handling during placement. ● Gamma Sterilized. Instrumentation Required: ❍ RENOVA Straight Implant Surgical Kit ❍ .048" Hex Driver for Placement Head and Cover Screw SDI 3.75mm RBM Straight Implant Description Catalog No. 3.75mm 3.75 x 8mm 13000 3.75 x 10mm 13001 3.75 x 11.5mm 13002 3.75 x 13mm 13003 length 3.75 x 16mm 13004 RDI 4.75mm RBM Straight Implant Description Catalog No. 4.75mm 4.75 x 8mm 13005 4.75 x 10mm 13006 4.75 x 11.5mm 13007 4.75 x 13mm 13008 length 4.75 x 16mm 13009 For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300 -9-
  • 10. Cover Screws & Healing Abutments Cover Screws Features: ● Included with all RENOVA implants. ● Offered separately for spare or replacement use. Instrumentation Required: ❍ .048" Hex Driver SDI 3.75mm RDI 4.5/4.75mm Description Catalog No. Catalog No. Cover Screw 10032 10033 Healing Abutments Features: ● Healing Abutments are designed to achieve optimal contouring of soft tissue, which provides for more aesthetic restorations. ● Occlusal surface is labeled with the implant prosthetic table (SDI and RDI) and cuff height. Instrumentation Required: ❍ .048" Hex Driver SDI 3.75mm Healing Abutment Cuff Height Catalog No. 1.5mm 10035 3mm 10036 5mm 10037 RDI 4.5/4.75mm Healing Abutment Cuff Height Catalog No. 1.5mm 10038 3mm 10039 5mm 10040 -10- For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300
  • 11. Cement-Retained Restorations Cement-On Crown (COC) Technical Considerations: ❍ A minimum inter-occlusal clearance of 4.0mm plus Abutment System the additional height of the restoration is required between the implant prosthetic table and the Features: occlusal plane. ● Cement-on Crown (COC) Abutments are intended ❍ It is recommended that bulk abutment reduction be for cement-retained restorations where conventional performed outside of the mouth due to risk of heat crown and bridge techniques are desired. The COC transfer to the implant. Abutment can be used for single or multi-unit (splinted) ❍ COC Abutments are made of titanium and are not restorations. designed for direct casting to the abutment. ● COC Abutments can be prepared as needed and impressioned directly using conventional crown Instrumentation Required: and bridge techniques, eliminating the need for ❍ .048" Hex Driver an impression post, analog and other prosthetic components. These abutments may also be used for provisional (temporary) restorations. Torque Recommendation: ❍ 30 Ncm for Abutment Screw Prosthetics Laboratory .048” Hex Driver 15° Angled Straight Locking COC Abutment COC Abutment Implant Analog Implant Impression Prosthetic 15° Angled Straight Locking COC Abutment COC Abutment Post (Hexed) Abutment Implant Impressioned Directly Impressioned Directly Healing Abutment Surgery Tapered Implant Straight Implant For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300 -11-
  • 12. Cement-Retained Restorations Straight Locking Cement-On Crown (COC) Abutments ● For use in single or multi-unit (splinted) restorations. ● Abutment margin can be prepared as necessary to follow gingival contours. ● COC Abutment may be impressioned directly using conventional crown and bridge impression techniques. Alternately, a locking implant impression post can be used to impression the Implant; allowing the laboratory to prepare the abutment and fabricate the restoration. ● Abutments include .048” hex titanium abutment screw. Additional screws are available separately. SDI 3.75mm RDI 4.5/4.75mm Description Catalog No. Catalog No. COC Abutment with Screw 43089 43090 Abutment Screw, Ti 43092 43092 Angled Locking Cement-On Crown (COC) Abutments ● For use in single or multi-unit (splinted) restorations where angle correction is needed. ● Pre-machined margins simplify abutment preparation and may be additionally prepared to follow gingival contours. ● COC Abutment may be impressioned directly using conventional crown and bridge impression techniques. Alternately, a locking implant impression post can be used to impression the implant; allowing the laboratory to prepare the abutment and fabricate the restoration. ● Abutments include .048” hex titanium abutment screw. Additional screws are available separately. SDI 3.75mm RDI 4.5/4.75mm Description Catalog No. Catalog No. 15°, 2mm Cuff 43094 43096 Abutment Screw, Ti 43100 43100 -12- For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300
  • 13. Implant Impression Posts (UCLA type) ● Used for single or multi-unit (splinted) restorations. ● Unique 3-piece design includes a long screw (open tray impressions) and a short screw (closed tray impressions). ● Transfers soft-tissue contours to the dental laboratory. SDI 3.75mm RDI 4.5/4.75mm Description Catalog No. Catalog No. Implant Impression Post 43127 43128 Implant Analogs ● Replicates the implant for use in the dental laboratory model. Prosthetics ● Stainless steel design allows use during soldering procedures. SDI 3.75mm RDI 4.5/4.75mm Description Catalog No. Catalog No. Implant Analog 43129 43130 For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300 -13-
  • 14. Screw-Retained Restorations UCLA Abutment System Technical Considerations: ❍ A minimum inter-occlusal clearance of 4.0mm Features: for the SDI and RDI UCLA Abutments is required ● The UCLA Abutment System can be used for single or between the implant prosthetic table and the top multi-unit (splinted) crown and bridge restorations. It of the abutment screw when seated. can also be used for bar attachment retained overdenture restorations. Instrumentation Required: ❍ .048” Hex Driver ● UCLA Abutments are used to fabricate highly aesthetic custom restorations that attach directly Torque Recommendation: to the implant. ❍ 30 Ncm for Abutment Screws .048” Hex Driver Laboratory UCLA Gold/Plastic UCLA UCLA UCLA Sleeve (Locking) Temporary Temporary Gold/Plastic Sleeve Sleeve Sleeve (Locking) (Non- (Non-Locking) Locking) Implant Analog Prosthetic Implant Implant Impression Post Impression Post Single Unit Multi-Unit (Splinted) Restorations Restorations Healing Abutment Surgery Tapered Implant Straight Implant -14- For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300
  • 15. UCLA Gold/Plastic Combo Sleeve ● The Gold/Plastic Combo combines the precision fit of a machined interface with the convenience of a castable plastic chimney. ● Specially designed geometry on the plastic chimney improves wax retention. ● Offered in both locking and non-locking versions. ● Includes a titanium .048” hex abutment screw. SDI 3.75mm RDI 4.5/4.75mm Description Catalog No. Catalog No. Locking 43006 43007 Non-Locking 43009 43010 Prosthetics Abutment Screws for ● Titanium screw included with each abutment and offered separately. UCLA Abutments ● .048” hex. ● Torque recommendation – 30Ncm. SDI 3.75mm RDI 4.5/4.75mm Description Catalog No. Catalog No. Abutment Screw, Ti 43116 43116 For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300 -15-
  • 16. Implant Impression Posts (UCLA type) ● Used for single or multi-unit (splinted) restorations. ● Unique 3-piece design includes a .048” hex long screw (open tray impressions) and a short screw (closed tray impressions). ● Transfers soft-tissue contours to the dental laboratory. SDI 3.75mm RDI 4.5/4.75mm Description Catalog No. Catalog No. Implant Impression Post 43127 43128 Implant Analogs ● Replicates the implant for use in the dental laboratory model. ● Stainless steel design allows use during soldering procedures. SDI 3.75mm RDI 4.5/4.75mm Description Catalog No. Catalog No. Implant Analog 43129 43130 UCLA Temporary Sleeve ● Titanium Temporary Sleeves provide a textured surface for acrylic when constructing provisional restorations. ● Available in non-hexed for multi-unit (splinted) restorations and hexed for single tooth restorations. ● Includes a titanium .048" hex abutment screw. SDI 3.75mm* RDI 4.5/4.75mm* Description Catalog No. Catalog No. Sleeve, Hexed 43110 43111 Sleeve, Non-Hexed 43113 43114 *Call for availability -16- For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300
  • 17. Screw-Retained Restorations Fixed Detachable Abutment System Features: ● The Fixed Detachable Abutment System is designed for ❍ A minimum inter-occlusal clearance of 6.9mm is multi-unit (splinted) crown and bridge restorations. required between the implant prosthetic table and the ● It is also commonly used for bar attachment retained top of the coping screw when seated. overdenture restorations. ❍ The tapered 12° side wall allows up to 24° of ● The Fixed Detachable Abutment provides excellent divergence between adjacent abutments. stability and allows for easier path of insertion due to its tapered design. Instrumentation Required: ❍ .062” Hex Driver Technical Considerations: Prosthetics .048" Hex Driver Laboratory Coping Screw (.048" Hex) Fixed Waxing Fixed Detachable Pin Detachable Plastic Sleeve Gold Sleeve Fixed Detachable Abutment Analog Prosthetic 1-Piece Impression Post 2-Piece Multi-Unit (Splinted) .048" Impression Post Hex Driver Restorations Healing Fixed .062" Hex Cap Detachable Driver Abutment AC Healing Abutment Surgery Regular Diameter (RD) components shown Components not shown to scale. For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300 -17-
  • 18. Screw-Retained Restorations Fixed Detachable Abutments ● Torque recommendation – 30Ncm. Instrumentation required: cuff ● .062" Hex Driver. SDI 3.75mm RDI 4.5/4.75mm Description Catalog No. Catalog No. 2mm Cuff, .062" Hex 43118 43120 4mm Cuff, .062" Hex 43119 43121 Healing Cap for Fixed Detachable Abutments ● Protects the abutment's internal threads and seating surface during healing. SDI 3.75mm RDI 4.5/4.75mm Description Catalog No Catalog No. Healing Cap, .048" Hex R2800-00 R2800-00 Impression Posts for Fixed Detachable Abutments ● 1-piece design is used for closed tray impressions. ● 2-piece design is used for open tray impressions. Impression Post, 1-Piece SDI 3.75mm RDI 4.5/4.75mm Description Catalog No. Catalog No. 1-Piece, 9mm, .048" Hex R9615-48 R9615-48 2-Piece, 9mm, .048" Hex R9515-48 R9515-48 Impression Post, 2-Piece -18- For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300
  • 19. Analog for Fixed Detachable Abutments ● Replicates the Fixed Detachable Abutment for use by the dental laboratory. ● Stainless steel design allows use during laboratory soldering procedures. SDI 3.75mm RDI 4.5/4.75mm Description Catalog No. Catalog No. Fixed Detachable Analog 410530-4 410530-4 Gold Sleeve and Plastic Sleeve for Fixed Detachable Abutments ● Gold Sleeve provides a precision machined interface between the restoration and the abutment. A Waxing Pin Prosthetics is available for waxing additional vertical height. ● Plastic Sleeve provides an economical alternative to Gold Cylinders and the extended chimney eliminates the need for a Waxing Pin. Gold Sleeve Plastic Sleeve ● Use with titanium coping screws, which are purchased separately. SDI 3.75mm RDI 4.5/4.75mm Description Catalog No. Catalog No. Gold Sleeve 410720-4 410720-4 Plastic Sleeve, 12mm 410450-4L 410450-4L Waxing Pin R9229-48 R9229-48 Coping Screw for Fixed Detachable Abutments ● Use with Fixed Detachable Abutment Gold and Plastic Sleeves. ● Torque recommendation - 20Ncm. SDI 3.75mm RDI 4.5/4.75mm Description Catalog No. Catalog No. .048" Hex (1.5mm head) R9490-48 R9460-48 For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300 -19-
  • 20. Overdenture Restorations Snap Abutment System Features: ● The Snap Abutment System is used with two or more implants for implant attachment retained overdenture restorations. ● The Snap Abutment threads directly into the implant. ● The Snap Abutment assembly is processed into the denture base either chairside or at the dental laboratory. ● Replacement retention inserts are available in a choice of 8, 10 and 12 Newtons. Technical Considerations: ❍ A minimum inter-occlusal clearance of 7.0mm plus the cuff height is required. ❍ Implants must be relatively parallel to one another – less than 20º total divergence. Snap Abutment Assembly Overdenture Snap Abutment Driver Laboratory Abutment Implant Analog Snap Abutment Assembly Implant Prosthetic Impression Post Snap Abutment Abutment Analog Overdenture .048” Hex Driver Abutment Driver Abutment Implant Impressioned Directly Impressioned Directly Healing Abutment Surgery Tapered Implant Straight Implant -20- For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300
  • 21. Snap Abutments ● Snap Abutments are packaged with a Snap Abutment Assembly [8 Newtons (N) – yellow] and laboratory spacer. ● Torque Recommendation – 30Ncm. Snap Abutment Assembly Instrumentation Required: ❍ Overdenture Abutment Driver cuff SDI 3.75mm RDI 4.5/4.75mm Description Catalog No. Catalog No. Snap Abutment 1mm Cuff 43102 43106 2mm Cuff 43103 43107 3mm Cuff 43104 43108 4mm Cuff 43105 43109 Snap Abutment Accessories Snap Abutment Assembly 8N Description Catalog No. Retaining Retention Abutment Analog L2804-01 Ring Insert Snap Retention Inserts, 8N, 10 N Qty 6 (includes blue retaining rings) L2806-08 Snap Retention Inserts, 10N, Retaining Retention Qty. 6 (includes blue retaining rings) L2806-10 Instrumentation & Motor Ring Insert Snap Retention Inserts, 12N, 12 N Qty. 6 (includes blue retaining rings) L2806-12 Retaining Retention Snap Retention Inserts, Multi-Pack, Ring Insert Qty. 6 (includes blue retaining rings) L2806-13 Assembly (8N) with lab spacer L2807-01 Seating Tool L2808-01 Abutment Seating Analog Tool For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300 -21-
  • 22. Implant Impression Posts (UCLA type) ● Used for single or multi-unit (splinted) restorations. ● Unique 3-piece design includes a .048" hex long screw (open tray impressions) and a short screw (closed tray impressions). ● Transfers soft-tissue contours to the dental laboratory. SDI 3.75mm RDI 4.5/4.75mm Description Catalog No. Catalog No. Implant Impression Post 43127 43128 Implant Analogs ● Replicates the implant for use in the dental laboratory model. ● Stainless steel design allows use during soldering procedures. SDI 3.75mm RDI 4.5/4.75mm Description Catalog No. Catalog No. Implant Analog 43129 43130 -22- For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300
  • 23. Surgical Kit for RENOVA Tapered Implants The RENOVA Tapered Implant Surgical Kit contains the instrumentation needed to place RENOVA 3.75 and 4.5mm tapered implants. Kit Features: ● Simple step-by-step drill sequences. ● RENOVA instrumentation offers improved efficiency, longevity and overall ease of use. ● Includes drills and taps for use with external irrigation. Description Catalog No. Surgical Kit for Tapered Implants 14012 Surgical Kit Item List: 2.3mm Round Marking Bur 3.75 x 11.5mm Surgical Tap .048" Hex Swivel Head Driver, Long 2.0mm Initial Drill 3.75 x 13mm Surgical Tap .048" Hex Driver, Latch-Type, Short 3.75 x 10mm Intermediate Drill 3.75 x 14.5mm Surgical Tap Conversion Handle for 3.75 x 11.5mm Intermediate Drill 4.5 x 8.5mm Surgical Tap Latch-Type Instruments 3.75 x 13mm Intermediate Drill 4.5 x 10mm Surgical Tap Ratchet Extender, Short & Long Placement Head Assembly Sleeves, 3.75 x 14.5mm Intermediate Drill 4.5 x 11.5mm Surgical Tap SDI & RDI 3.75 x 10mm Finishing Drill 4.5 x 13mm Surgical Tap Component Pack 3.75 x 11.5mm Finishing Drill SDI 3.5mm NP Placement Head Instrumentation & Motor Grommet Plugs, 2 Packs of 10 3.75 x 13mm Finishing Drill SDI 5.5mm NP Placement Head Cleaning Detergent 3.75 x 14.5mm Finishing Drill RDI 3.5mm NP Placement Head 4.5 x 8.5mm Intermediate Drill RDI 5.5mm NP Placement Head 4.5 x 10mm Intermediate Drill SDI 15mm NP Placement Head* 4.5 x 11.5mm Intermediate Drill RDI 15mm NP Placement Head* 4.5 x 13mm Intermediate Drill Locking Drill Extender 4.5 x 8.5mm Finishing Drill Surgical Ratchet 4.5 x 10mm Finishing Drill Stabilizing Wrench 4.5 x 11.5mm Finishing Drill Hand Adapter 4.5 x 13mm Finishing Drill Ratchet Adapter, 8mm 3.75mm Countersink Drill, Tapered Ratchet/Tap Adapter, 12mm 4.5mm Countersink Drill, Tapered Handpiece Adapter 3.75 x 10mm Surgical Tap .048" Hex Swivel Head Driver, Short * Call for availability For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300 -23-
  • 24. Surgical Instrumentation for RENOVA Tapered Implants For recommended drill sequences and details on drill depth markings, refer to page 6. Round Bur & Initial Drill ● Round Bur is used for marking the implant site prior to beginning the drilling sequence. ● Initial Drill is the first drill used for all RENOVA Tapered Implants. Description Catalog No. Round Bur Round Marking Bur, 2.3mm L1405-23-00 2.0mm Initial Drill 14071 Initial Drill Drills for RENOVA Tapered ● Specific drill is used for each implant size. ● For use with external irrigation. SDI 3.75mm Tapered Intermediate Drills SDI 3.75mm Tapered Finishing Drills Description Catalog No. Description Catalog No. 3.75 x 10mm 14072 3.75 x 10mm 14076 3.75 x 11.5mm 14073 3.75 x 11.5mm 14077 3.75 x 13mm 14074 3.75 x 13mm 14078 3.75 x 14.5mm 14075 3.75 x 14.5mm 14079 RDI 4.5mm Tapered Intermediate Drills RDI 4.5mm Tapered Finishing Drills Description Catalog No. Description Catalog No. 4.5 x 8.5mm 14080 4.5 x 8.5mm 14084 4.5 x 10mm 14081 4.5 x 10mm 14085 4.5 x 11.5mm 14082 4.5 x 11.5mm 14086 4.5 x 13mm 14083 4.5 x 13mm 14087 -24- For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300
  • 25. Surgical Taps for RENOVA Tapered Implants ● For pre-tapping bone prior to tapered implant placement. ● Latch-type tap can be used in a handpiece or can be operated manually when used with the Surgical Ratchet (L1702-01) and Ratchet/Tap Adapter (L1806-05). SDI 3.75mm Tapered Surgical Tap Description Catalog No. 3.75 x 10mm 14088 3.75 x 11.5mm 14089 3.75 x 13mm 14090 3.75 x 14.5mm 14091 Instrumentation & Motor RDI 4.5mm Tapered Surgical Tap Description Catalog No. 4.5 x 8.5mm 14092 4.5 x 10mm 14093 4.5 x 11.5mm 14094 4.5 x 13mm 14095 For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300 -25-
  • 26. Surgical Kit for RENOVA Straight Implants The RENOVA Straight (parallel walled) Implant Surgical Kit contains the instrumentation needed to place RENOVA 3.75 and 4.75mm straight implants. Kit Features: ● Simple step-by-step drill sequences. ● RENOVA instrumentation offers improved efficiency, longevity and overall ease of use. ● Includes drills and taps for use with external irrigation. Description Catalog No. Surgical Kit for Straight Implants 13010 Surgical Kit Includes: 2.3mm Round Marking Bur 2.35mm Depth Gauge Conversion Handle for Latch-Type 2.0mm Initial Drill SDI 3.5mm NP Placement Head Instruments 2.35 x 11.5mm Drill SDI 5.5mm NP Placement Head Ratchet Extender, Short & Long Placement Head Assembly Sleeves, 2.35 x 16mm Drill RDI 3.5mm NP Placement Head SDI & RDI 2.8 x 11.5mm Drill RDI 5.5mm NP Placement Head Component Pack 2.8 x 16mm Drill SDI 15mm NP Placement Head* Grommet Plugs, 2 Packs of 10 3.25 x 11.5mm Drill RDI 15mm NP Placement Head* Cleaning Detergent 3.25 x 16mm Drill Locking Drill Extender 3.25/4.25mm Pilot Drill Surgical Ratchet 4.25 x 11.5mm Drill Stabilizing Wrench 4.25 x 16mm Drill Hand Adapter 3.75mm Countersink Drill Ratchet Adapter, 8mm 4.75mm Countersink Drill Ratchet/Tap Adapter, 12mm 3.75 x 11.5mm Surgical Tap Handpiece Adapter 3.75 x 16mm Surgical Tap .048" Hex Swivel Head Driver, Short 4.75 x 11.5mm Surgical Tap .048" Hex Swivel Head Driver, Long 4.75 x 16mm Surgical Tap .048" Hex Driver, Latch-Type, Short * Call for availability -26- For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300
  • 27. Surgical Instrumentation for RENOVA Straight Implants For recommended drill sequences and details on drill depth markings, refer to page 7. Round Bur & Initial Drill ● Round Bur is used for marking the implant site prior to beginning the drilling sequence. ● Initial Drill is the first drill used for all RENOVA Straight Implants. Description Catalog No. Round Marking Bur, 2.3mm L1405-23-00 Round Bur Initial Drill 2.0mm Initial Drill 14071 Drills for RENOVA Straight Implants Initial Drills ● ● For use with external irrigation. Offered in 2 lengths. Short – for RENOVA straight implants up to 11.5mm Long – for RENOVA straight implants up to 16mm Description Catalog No. 2.35 x 11.5mm Drill 13031 2.35 x 16mm Drill 13032 Intermediate & Finishing Drills Instrumentation & Motor Description Catalog No. 2.8 x 11.5mm Drill 13033 2.8 x 16mm Drill 13034 3.25 x 11.5mm Drill 13035 3.25 x 16mm Drill 13036 4.25 x 11.5mm Drill 13038 4.25 x 16mm Drill 13039 Pilot Drill ● Pilot Drill helps ensure a smooth and accurate transition between the 3.25mm and 4.25mm drills. ● For use with external irrigation. Description Catalog No. 3.25/4.25 Pilot Drill 13037 Countersink Drills ● Contours ridge prior to placing 3.75mm and 4.75mm RENOVA Straight Implants, allowing implant and cover screw placement at or below the surrounding bone level. ● For use with external irrigation. Description Catalog No. 3.75mm Countersink Drill 13040 4.75mm Countersink Drill 13041 For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300 -27-
  • 28. Surgical Instrumentation for RENOVA Straight Implants Surgical Taps for RENOVA Straight Implants ● For pre-tapping bone prior to implant placement. ● Latch-type tap can be used in a handpiece or can be operated manually when used with the Surgical Ratchet (L1702-01) and Ratchet/Tap Adapter (L1806-05). ● For use with external irrigation. ● Offered in 2 lengths. Short – for RENOVA straight implants up to 11.5mm Long – for RENOVA straight implants up to 16mm SDI 3.75 Straight Surgical Taps Description Catalog No. 3.75 x 11.5mm Tap 13042 3.75 x 16mm Tap 13043 RDI 4.75 Straight Surgical Taps Description Catalog No. 4.75 x 11.5mm Tap 13044 4.75 x 16mm Tap 13045 -28- For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300
  • 29. Additional Surgical Instrumentation for Tapered and Straight Implants Depth Gauge ● Verifies depth of the surgical site. ● Depth marks correspond to implants lengths. Description Catalog No. 2.35mm Depth Gauge (for straight implants) 10589 Parallel Pins ● Used as a visual guide during surgery to help ensure parallel implant placement. Description Catalog No. 2.0mm Parallel Pin (tapered & straight implants), 2-pk 10028* 2.35/2.8mm Parallel Pin (straight implants), 2-pk 13029* Surgical Ratchet, Adapter and Extenders Description Catalog # ● Ratchet is used for manual operation of the Surgical Taps and/or final tightening of the implant. Surgical Ratchet L1702-01 ● Ratchet Extenders enable clearance of adjacent teeth. Ratchet Adapter, 8mm L1806-04 (for NP Placement Heads) Instrumentation & Motor Ratchet/Tap Adapter, 12mm L1806-05 (for NP Placement Heads & Surgical Ratchet Latch-Type Surgical Taps) Ratchet Extender, Short & Long L1703-01 (to extend the Ratchet Adapters) Replacement O-Rings for L1806-03 Ratchet Adapter, Qty. 4 NP Ratchet Adapters Ratchet Extenders Narrow Profile (NP) ● Narrow design improves intra-oral access during implant placement. ● Color anodized for easy identification of implant/placement head junction. Placement Heads ● External flats correspond to the flats of the implants internal hex for easy indexing. Instrumentation Required: ❍ .048" Hex Driver SDI 3.75mm RDI 4.5/4.75mm Description Catalog No. Catalog No. 3.5mm Placement Head 10585 10587 5.5mm Placement Head 10586 10588 15mm Placement Head 10579* 10580* * Call for availability For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300 -29-
  • 30. Direct-to-Implant ● Connects directly to RENOVA Tapered and Straight Implant prosthetic connections for adjusting implant insertion depth during first stage surgery. Ratchet Adapters ● Used in conjunction with the Surgical Ratchet. SDI 3.75mm RDI 4.5/4.75mm Description Catalog No. Catalog No. Adapter, short 10590 10592 Adapter, long 10591 10593 Stabilizing Wrench ● ● For use only with Narrow Profile (NP) Placement Heads. Use open or closed end to stabilize the implant during loosening of the placement head screw. ● Features a special pin to engage the Ratchet Adapter (L1806-04) and stabilize the implant during manual placement. Description Catalog No. Stabilizing Wrench L1709-01 Handpiece ● Inserts into the handpiece and connects to the RENOVA NP Placement Placement Adapter Head for motor driven implant placement. Description Catalog No. Handpiece Adapter (for NP placement heads) L1406-01 Hand Adapter for ● Connects to the RENOVA NP Placement Head and carries the implant to the surgical site for hand delivered implant placement. Narrow Profile (NP) ● Can also be used to remove the placement head by inserting a hex Placement Head driver through the top end to loosen the screw and then carry the placement head assembly out of the mouth. Description Catalog No. Hand Adapter (for NP placement heads) L1406-02 -30- For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300
  • 31. Titanium Forceps ● Titanium Forceps are used to handle implants and other titanium components to avoid possible contamination. Description Catalog No. Titanium Forceps R9119 Locking Drill Extender ● Adds 17mm of length to any latch-type drill or driver. ● Useful when drilling next to adjacent teeth. Description Catalog No. Locking Drill Extender L1404-01 Implant Sizing Overlays ● Use these transparent overlays with radiographs for pre-surgical assessment and implant selection. ● 100% (1:1) Sizing Overlay for use with peri-apical x-rays. ● 125% Sizing Overlay for panoramic radiographs. Instrumentation & Motor Description Catalog No. Tapered Implant 100% (1:1) Sizing Overlay 14050* Tapered Implant 125% Sizing Overlay 14051* Straight Implant 100% (1:1) Sizing Overlay 13027* Straight Implant 125% Sizing Overlay 13028* * Call for availability For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300 -31-
  • 32. Wrenches and Drivers Accu-Torque Wrenches & Accessories 20Ncm Torque Wrench ● Pre-calibrated wrenches precisely deliver proper torque. ● Use with Accu-Torque Drivers. ● Conversion Handle allows use of Accu-Torque Drivers as hand drivers. 30Ncm Torque Wrench Description Catalog No. Accu-Torque Wrench, 20Ncm ISS1101 Accu-Torque Wrench, 30Ncm ISS1102 Conversion Handle for Conversion Handle for Accu-Torque Drivers, Swivel Head ISS1112 Accu-Torque Drivers Replacement O-Rings for Accu-Torque Drivers, Qty 6 ISS1111 Torque Wrench Care and Maintenance Cleaning and Sterilization: ● Before initial use and after each procedure, clean the torque wrench with a wet towel or disinfectant wipe. Rinse under warm tap water and wipe dry. ● Before sterilization, spray an approved (handpiece type) instrument lubricant into the opening at the back of the wrench. ● Sterilize with the handle in the broken position. ● Wrench may be sterilized by steam autoclave. Do not exceed 125°C (257°F). ● Always use the dry cycle. ● Do not use “Flash Sterilization” techniques. ● After sterilization, reset the torque break handle, then manually “break” the hinge again to ensure the wrench is operating correctly. Calibration: For proper function and accurate control, Accu-Torque Wrenches should be calibrated every 6 months (or after 100 autoclave cycles). For calibration or repair, wrenches should be sent directly to: Micromotor Repair Station 151 East Columbine Avenue Santa Ana, CA 92707 USA 800-562-6204 Outside the U.S.: 714-546-4045 * For Lifecore’s Torque Wrench warranty information, please reference the Ordering & Warranty Information section on page 37. -32- For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300
  • 33. .048" Hex Drivers ● Use with .048" hex placement head screws, healing abutments, abutment screws and impression posts. ● Tapered hex tip allows screws to be carried to the implant site. Description Catalog No. .048" Hex Driver, Swivel Head, Short (8mm shaft/19mm total length) R9121 .048" Hex Driver, Swivel Head, Long (13mm shaft/24mm total length) R9122 .048" Hex Driver, Latch-Type, Short (23mm total length) L1400-48-23 Hex Latch Type Accu- .048" Hex Driver, Latch-Type, Long (28mm total length) L1400-48-28 Driver Driver Torque Driver .048" Hex Driver, for Accu-Torque Wrench, Short (8mm shaft) ISS1104 .048" Hex Driver, for Accu-Torque Wrench, Long (15mm shaft) ISS1109 .062" Hex Drivers ● Used for Fixed Detachable Abutments. ● Tapered hex tip allows abutments to be carried to the implant site. Description Catalog No. .062" Hex Driver, Swivel Head, Short (8mm shaft/19mm total length) L2100-62-19 .062" Hex Driver, Swivel Head, Long (13mm shaft/24mm total length) L2100-62-24 .062" Hex Driver, Latch-Type, Short (23mm total length) L1400-62-19 .062" Hex Driver, Latch-Type, Long (28mm total length) L1400-62-23 Instrumentation & Motor Swivel Latch- Accu- Head Type Torque Driver Driver Driver .062" Hex Driver, for Accu-Torque Wrench, Short (8mm shaft) ISS1119 .062" Hex Driver, for Accu-Torque Wrench, Long (15mm shaft) ISS1120 Overdenture ● Used for Snap Abutments. Abutment Drivers Description Catalog No. Overdenture Driver, Swivel Head (8mm shaft) L2100-96-19 Overdenture Driver, Latch-Type (20mm total length) L1404-96-20 Overdenture Driver, for Accu-Torque Wrench* (8mm shaft) L2101-96-16 Swivel Latch Accu- Head Type Torque Driver Driver Driver For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300 -33-
  • 34. Lab Tools & Other Products Hader Bar and Clip System ● A simple, effective bar system, featuring a plastic bar pattern and nylon clips, which are processed into the removable prosthesis. ● Mechanical snap retention. Hader Castable Bar Description Catalog No. Hader Hader Castable Bar And Clip System ISS185H Processing Clip (includes 1 Hader Bar, 6 Processing Clips, 6 Final Clips & 1 Hader Tool) Hader Hader Castable Bar ISS185B Final Clip Hader Processing Clips, Qty. 6 ISS185HP Hader Final Clips, Qty. 6 ISS185HR Hader Metal Hader Clip Metal Housings, Qty. 6 ISS526H Housing Clip Hader Tool ISS185T Hader Tool -34- For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300
  • 35. Component Pack ● Organizes small components such as the implant cover screws, placement heads, etc. ● Autoclavable design with slide lid interlocks into the base of the surgical kits. ● Optionally, may be used as a stand-alone organizer. Description Catalog No. Component Pack L1812-01 Instrument Cleaning Detergent • For use with all Lifecore instruments and surgical kits. • Includes recommended cleaning instructions. Cleaning Detergent L1819-01 Instrumentation & Motor For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300 -35-
  • 36. LC5000 Surgical Motor System LC5000 Features: Lifecore’s LC5000 is a simple, user-friendly motor with abundant features for implantology and oral and maxillofacial microsurgery. Carefully designed features, place the LC5000 in a class of its own. The unique motor with large on-screen graphics display, straight- forward console layout, foot pedal control and Program/Patient Information Smart Cards exemplifies high performance. Since the LC5000 is manufactured specifically for Lifecore Biomedical, it comes complete with Lifecore’s surgical protocol preprogrammed and is backed by a full one-year warranty. In addition, the compact design helps maximize surgical work area. ● Compact design helps maximize surgical work area ● Large, easy-to-read display clearly identifies motor settings including procedure, rpm, torque, irrigation flow rate, etc. ● Unique foot pedal design with large buttons simplifies access to functions during surgery. Also provides variable speed control. ● A versatile 20:1 handpiece can be used for drilling, tapping and implant placement (sold separately). ● Torque Bar display provides a visual reference of torque delivered during procedures. ● Program Data Smart Card instantly saves/retrieves up to 20 custom program settings. ● Patient Data Smart Card & PC Software stores patient information for documenting patient treatment data. ● Auto-Calibration function for motor/handpiece enables superior rpm and torque control. ● Full one-year warranty included. Extended warranty options also available. Contact Lifecore Client Service or your sales representative for more details. Lifecore LC5000 Surgical Motor System Package Description Catalog # LC5000 Surgical Motor and Console 10594 20:1 Handpiece 10595 10-pack of Sterile Irrigation Tubing 10598 Testing Gauge for Latch-Type Instrument Shanks 10602 PC Software Updating Kit 10611 Service Oil, 50ml* 10604 -36- For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300
  • 37. Lifecore LC5000 Surgical Motor Accessories Description Catalog # LC5000 Surgical Motor Unit 10594 20:1 Reduction Contra-Angle Handpiece - for implant surgery (up to 150,000 rpm when used with LC5000 Motor) 10595 1:1 High Speed Straight Handpiece (up to 30,000 rpm when used with LC5000 Motor) 10596 1:5 High Speed Straight Handpiece (up to 30,000 rpm when used with LC5000 Motor) 10597 Irrigation Tubing, Sterile, 10-pack 10598 Irrigation Needle, 2-pack 10599 Y-Connector, 2-pack 10600 Y-Tubing, 2-pack 10601 Testing Gauge (for latch-type instrument shanks) 10602 Travel Case (for LC5000 Motor System) 10603 Service Oil, 50ml* 10604 Service Oil, 250ml (6-pack)* 10613 Instrumentation & Motor Sterilization Protector for Motor 10607 Sterilization Case 10606 Patient Data Smart Card, 1-pack (for LC5000) 10608 Program Data Smart Card, 1-pack (for LC5000) 10609 System Software Card, 1-pack (for LC5000) 10610 PC Software Updating Kit 10611 USB Cable Adapter 10612 *Due to aerosol service oil can, special shipping and handling is required. Please contact Client Service for shipping rates. For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300 -37-
  • 38. Tissue Regeneration Products ® CAPSET Calcium Sulfate Bone Graft Barrier CAPSET Calcium Sulfate Bone Graft Barrier is a barrier designed to be used over bone grafting material to aid bone regeneration. Each CAPSET kit contains proprietary formulation calcium sulfate and an accelerating solution. When mixed together, they form a paste, which is molded into place over bone grafting material. CAPSET Features: • Bioresorbable • Conforms to Defect • Easy to Use • Positive Tissue Response • Offers Longer Working Time (SlowSet) • Ideal for Multiple Defects (SlowSet) The 0.25gm reserve cup of calcium sulfate can act as a binder when mixed with Bone Allograft, Autogenous Bone, Xenografts or Synthetic Bone grafting material. • Improves handling properties • Reduces particle migration Description Catalog # CAPSET 1.0gm 4061-10 CAPSET 2.0gm 4061-20 CAPSET SlowSet 1.0gm 4064-10 CAPSET SlowSet 2.0gm 4064-20 0.25gm Reserve Cup, 6-Pack 4061-025 -38- For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300