SlideShare une entreprise Scribd logo
1  sur  25
Motorized
               Damper/Diffuser




Tel. 82-2-523-5161~3       omniventsystem.com
OvM Diffuser                                             2/24




               Residential Buildings, Apartment Houses
OvM Diffuser                                              3/24




               Office Buildings, Auditoriums, Libraries
OvM Diffuser                                   4/24




               New Green Technology is Here!
Current Methods                                  ㈜ 옴니벤트   5/24




                  Traditional Air Conditioning
                           Method
Current Methods                                                       6/24



                  1) Single Zone Air Conditioning System
                            (One Zone Control)




                                           Air Return types:
                                          • Duct Return
                                          • Room Space + Duct Return
                                          • Ceiling Space + Duct Return




                   No Independent Zone Control
                  → Constant Energy Consumption
Current Methods                                                ㈜ 옴니벤트   7/24



                  2) Multi Split System (Multi Zone Control)




                        Independent Zone Control
                         ↔ High Installation Cost
Current Methods                                            ㈜ 옴니벤트   8/24


                       3) Individual Multi Duct System
                             (Multi Zone Control)
       Variation A




                        Independent Zone Control
                  ↔ Unrealistic Ceiling Space Management
Current Methods                                                          9/24


                        3) Individual Multi Duct System
                              (Multi Zone Control)
       Variation B




                                Utilizing Ceiling space as return path



                  Independent Zone Control, Low Install Cost
                      ↔ Inefficient Air Flow Management
Current Methods                                                                                              10/24


                                             Characteristic of Multi Zone Systems
                                                                  Merits                 Demerits
                                                             • Independent     • High Install Cost
   MULTI SPLITs




                                                               zone control
                                                                               • Difficult to fix
                                                             • Does not          refrigerants leaking
                                                               need high
                                                               ceiling space   • Need Additional
                                                                                 Vent system
                                                             • Independent     • Inefficient Air Flow
   ALL AIR MULTI DUCT SYSTEM




                               Variation B                     zone control      Control            Detail

                                                             • Less            • Low Cooling Efficiency
                                                               Construction      due to common air
                                                               cost vs.          return (variation B)
                                                               Multi Split
                                                                               • Need High
                                                             • Ventilation       Ceiling Space
                                                               can be
                                                               integrated
Current Methods                                             11/24



                        Current Multi Zone Systems


 WHAT to improve to meet the consumer needs ?


       Independent Zone control with

       • Less Installation cost
       • Ease of Maintenance
       • Less Energy Consumption




                         Solution
                                       OmniVent Motorized
                                             Diffuser
New Concept / New Technology                               12/24




                      Introduction to New Technology
                              Economical & Practical
                         Independent Zone Control System
                                      with

                                   mni-
                                  ent otorized
New Concept / New Technology                              13/24




         What is                   ?
                      All in One Damper & Diffuser with
                      Automatic On/Off Control
                      Air Balancing
New Concept / New Technology                                          14/24



                               OvM Diffuser


                                                  Switch on
                                                  Only Where
                                                  you need,



                                              < All Cost Minimization >

                                              •Minimal Installation Cost
                                              •Easy and low Maintenance
                                              •Automatic Air Balancing
                                              •Low Electricity Consumption
New Concept / New Technology                                     15/24




                  Concept of OmniVent Independent Zone Control
New Concept / New Technology                                                         16/24


                          Concept drawings utilizing OvM Diffuser




           [ Installed with return air duct ]      [ Ceiling space to return air ]
New Concept / New Technology                     17/24



                                  Applications

            where Independent Zone
            control is needed




      Spot cooling in Large Open Area




                              to VAV
                System
OvM Diffuser                                                                       18/24



                              Facts about OvM Diffuser

     Install & Maint. Friendly                    High Credibility
        Significant cost saving                      Incremental Adjust. w/
         vs. Multi Split                               complete turn off control
                                                      Easy Air Balancing




     User Friendly
        Super Easy Operation
        Neat Ceiling Finish
        Easy to check any problem



     Environment Friendly
        Less Energy Consumption
OvM Diffuser                                                      ㈜ 옴니벤트    19/24



                      Facts about OvM Diffuser
                        Air Volume vs. Opening Rates

         PB Damper       OvM Diffuser             Linear Air Vol. Control




          OB Damper




                         150 Ø Neck
                         AK: 130 cm2
OvM Diffuser                                                          ㈜ 옴니벤트     20/24



                          Facts about OvM Diffuser

                              Automatic Air Flow Control

      Ventilation / Cooling                                Horizontal Spreads




       Heating                                              Vertical Discharge
OvM Diffuser                                                         ㈜ 옴니벤트   21/24



                           Facts about OvM Diffuser
                            Reliability of Component (Motor)

                                Supplied by “Reili”
                       Low Noise, Low Vibe. Stepping Motor

                            Major Supply to Korean Companies:
       Exporting to         LG Electronics 25 Million per Annum (yr 2008)
    Worldwide (inc. US)     Samsung         20 Million
                            Ungjin Korway 30 Million

                            Swing Louver of Multi Split, Bidet, Micro Wave,
         Application
                            Washer drain control, Hot water distributor…

                          Error Rates 200 PPM (0.02%)




                            1% Additional Parts Supply
OvM Diffuser                                                                      ㈜ 옴니벤트           22/24



                         Facts about OvM Diffuser
                        Comparison with other technology
                      OvMd Diffuser               Similar Idea                Other Idea


      Appearance
        & Inner
       Structure

                                            Japan:6-011177(Mitsubishi)
         Patent       10-2009-0004403
                                            U.S.: 6,176,777 (E.H.Price)
                                                                                No Patent

     Placement of                                                          Motorized Damper
                     Inside Diffuser Cone    Upper Outside of Dish
        Motor                                                                 inside Duct

     Maintenance            Easy                     Difficult                  Difficult

       Pressure                              Big, due to Motor facing     Big, due to additional
                         Very small
         Loss                                        air flow                    Damper

      Initial Cost          100%                  300% ~ 400%                     160%

        Ease of                             Can apply ONLY in huge
                          Very Easy                                           Not Practical
      Installation                               Duct system

                             
OvM Diffuser                                                             ㈜ 옴니벤트    23/24



                            Facts about OvM Diffuser
                             Comparison with other technology

               Diffusers using Wax                              OvM Diffuser




       • Variable Air   Volume control using          • Precise
                                                              & Responsive Air
       Wax                                            Discharge control

       • No Air Blocking (complete closing)           • Self Opening rate control
       function
                                                      • Complete Closure Mode
       • High Priced
                                                      • Durability & Credibility
S Y S T E M

omniventsystem.com
Attach
Current Methods                                                        ㈜ 옴니벤트
                                                                                      #1


                  Air Flow Management for Multi Duct System
                                                                                 Back
 Variation B

                                  Air Flow & Cooling Efficiency

                                             Air supply ducts block ceiling space
                                            (return path)
                                             resulting in inefficient energy control

                                  Pressure Difference between Rooms

                                             Makes door operation difficult

                                  Air Volume Control

                                             Large Control Variation of the
                                            conventional dampers makes Air
                                            volume control inefficient


                                  Diffuser Balancing

                                             Not possible when independent
                                            ventilation activated

Contenu connexe

En vedette

Subsonic and supersonic air intakes
Subsonic and supersonic air intakesSubsonic and supersonic air intakes
Subsonic and supersonic air intakesSanjay Singh
 
Gérer et diffuser ses données: principes et bonnes pratiques
Gérer et diffuser ses données: principes et bonnes pratiquesGérer et diffuser ses données: principes et bonnes pratiques
Gérer et diffuser ses données: principes et bonnes pratiquesMathieu Saby
 
Gas dynamics and jet propulsion – presentationof problemsanswers
Gas dynamics and jet propulsion – presentationof problemsanswersGas dynamics and jet propulsion – presentationof problemsanswers
Gas dynamics and jet propulsion – presentationof problemsanswersVaidyanathan Ramakrishnan
 
Aircraft propulsion combustor diffusor
Aircraft propulsion   combustor diffusorAircraft propulsion   combustor diffusor
Aircraft propulsion combustor diffusorAnurak Atthasit
 

En vedette (9)

Subsonic and supersonic air intakes
Subsonic and supersonic air intakesSubsonic and supersonic air intakes
Subsonic and supersonic air intakes
 
Gérer et diffuser ses données: principes et bonnes pratiques
Gérer et diffuser ses données: principes et bonnes pratiquesGérer et diffuser ses données: principes et bonnes pratiques
Gérer et diffuser ses données: principes et bonnes pratiques
 
Intro To Evaporative Cooling
Intro To Evaporative CoolingIntro To Evaporative Cooling
Intro To Evaporative Cooling
 
Gas dynamics and jet propulsion – presentationof problemsanswers
Gas dynamics and jet propulsion – presentationof problemsanswersGas dynamics and jet propulsion – presentationof problemsanswers
Gas dynamics and jet propulsion – presentationof problemsanswers
 
EVAPORATIVE cool
EVAPORATIVE coolEVAPORATIVE cool
EVAPORATIVE cool
 
What Is Evaporative Cooling
What Is Evaporative CoolingWhat Is Evaporative Cooling
What Is Evaporative Cooling
 
Nozzle and diffuser
Nozzle and diffuserNozzle and diffuser
Nozzle and diffuser
 
Aircraft propulsion combustor diffusor
Aircraft propulsion   combustor diffusorAircraft propulsion   combustor diffusor
Aircraft propulsion combustor diffusor
 
Wind tunnel design
Wind tunnel designWind tunnel design
Wind tunnel design
 

Similaire à OmniVent Motorized Diffuser

Ga ‘Technology Defined For Sustained Greenary ’
Ga  ‘Technology Defined For Sustained Greenary ’Ga  ‘Technology Defined For Sustained Greenary ’
Ga ‘Technology Defined For Sustained Greenary ’salith Moosa
 
Linked In Radiant Panel Presentation
Linked In Radiant Panel PresentationLinked In Radiant Panel Presentation
Linked In Radiant Panel PresentationDarren_Alexander
 
XANT company presentation
XANT company presentationXANT company presentation
XANT company presentationXANT
 
XANT company presentation
XANT company presentationXANT company presentation
XANT company presentationAlex De Broe
 
Introduction to VRF
Introduction to VRF Introduction to VRF
Introduction to VRF John Chavez
 
Closer Look At Infrastructure Sustainability - Engineering Perspective - Infr...
Closer Look At Infrastructure Sustainability - Engineering Perspective - Infr...Closer Look At Infrastructure Sustainability - Engineering Perspective - Infr...
Closer Look At Infrastructure Sustainability - Engineering Perspective - Infr...Loay Ghazaleh MBA, BSc Civil Eng.
 
TandG_Building_Tech_Specs.pdf
TandG_Building_Tech_Specs.pdfTandG_Building_Tech_Specs.pdf
TandG_Building_Tech_Specs.pdfRobert Tannoury
 
Ultra Clean Ventilation for Operating Theatres
Ultra Clean Ventilation for Operating TheatresUltra Clean Ventilation for Operating Theatres
Ultra Clean Ventilation for Operating TheatresHoworth Air Technology
 
Waste Water aeration system challenges solutions
Waste Water aeration system challenges solutionsWaste Water aeration system challenges solutions
Waste Water aeration system challenges solutionsManish Patel
 
Centralized ac system
Centralized ac systemCentralized ac system
Centralized ac systemFebin Siby
 
Mechadyne Diesel VLD
Mechadyne Diesel VLDMechadyne Diesel VLD
Mechadyne Diesel VLDlawrni
 
Neslab Thermo Flex Deluxe
Neslab Thermo Flex DeluxeNeslab Thermo Flex Deluxe
Neslab Thermo Flex Deluxeboswjw
 
Verasys technical introduction
Verasys technical introductionVerasys technical introduction
Verasys technical introductionRobert Stone
 
Active Beam Commissioning Overview
Active Beam Commissioning   OverviewActive Beam Commissioning   Overview
Active Beam Commissioning OverviewDarren_Alexander
 
Vrviii new presentation revised4
Vrviii new presentation revised4Vrviii new presentation revised4
Vrviii new presentation revised4Mahmoud Ezz
 

Similaire à OmniVent Motorized Diffuser (20)

Ga ‘Technology Defined For Sustained Greenary ’
Ga  ‘Technology Defined For Sustained Greenary ’Ga  ‘Technology Defined For Sustained Greenary ’
Ga ‘Technology Defined For Sustained Greenary ’
 
Comparison between vrv vrf brands &amp; suppliers @ uae market-July 2017-by g...
Comparison between vrv vrf brands &amp; suppliers @ uae market-July 2017-by g...Comparison between vrv vrf brands &amp; suppliers @ uae market-July 2017-by g...
Comparison between vrv vrf brands &amp; suppliers @ uae market-July 2017-by g...
 
Linked In Radiant Panel Presentation
Linked In Radiant Panel PresentationLinked In Radiant Panel Presentation
Linked In Radiant Panel Presentation
 
XANT
XANTXANT
XANT
 
XANT company presentation
XANT company presentationXANT company presentation
XANT company presentation
 
XANT company presentation
XANT company presentationXANT company presentation
XANT company presentation
 
Introduction to VRF
Introduction to VRF Introduction to VRF
Introduction to VRF
 
Closer Look At Infrastructure Sustainability - Engineering Perspective - Infr...
Closer Look At Infrastructure Sustainability - Engineering Perspective - Infr...Closer Look At Infrastructure Sustainability - Engineering Perspective - Infr...
Closer Look At Infrastructure Sustainability - Engineering Perspective - Infr...
 
TandG_Building_Tech_Specs.pdf
TandG_Building_Tech_Specs.pdfTandG_Building_Tech_Specs.pdf
TandG_Building_Tech_Specs.pdf
 
Ultra Clean Ventilation for Operating Theatres
Ultra Clean Ventilation for Operating TheatresUltra Clean Ventilation for Operating Theatres
Ultra Clean Ventilation for Operating Theatres
 
Waste Water aeration system challenges solutions
Waste Water aeration system challenges solutionsWaste Water aeration system challenges solutions
Waste Water aeration system challenges solutions
 
Mls Brochure Ep P2
Mls Brochure Ep P2Mls Brochure Ep P2
Mls Brochure Ep P2
 
Centralized ac system
Centralized ac systemCentralized ac system
Centralized ac system
 
LogiCool Inrak Data Centre Cooling 10-60kW
LogiCool Inrak Data Centre Cooling 10-60kWLogiCool Inrak Data Centre Cooling 10-60kW
LogiCool Inrak Data Centre Cooling 10-60kW
 
Mechadyne Diesel VLD
Mechadyne Diesel VLDMechadyne Diesel VLD
Mechadyne Diesel VLD
 
Neslab Thermo Flex Deluxe
Neslab Thermo Flex DeluxeNeslab Thermo Flex Deluxe
Neslab Thermo Flex Deluxe
 
Verasys technical introduction
Verasys technical introductionVerasys technical introduction
Verasys technical introduction
 
Active Beam Commissioning Overview
Active Beam Commissioning   OverviewActive Beam Commissioning   Overview
Active Beam Commissioning Overview
 
Vrviii new presentation revised4
Vrviii new presentation revised4Vrviii new presentation revised4
Vrviii new presentation revised4
 
Vrf
VrfVrf
Vrf
 

Dernier

"ML in Production",Oleksandr Bagan
"ML in Production",Oleksandr Bagan"ML in Production",Oleksandr Bagan
"ML in Production",Oleksandr BaganFwdays
 
Training state-of-the-art general text embedding
Training state-of-the-art general text embeddingTraining state-of-the-art general text embedding
Training state-of-the-art general text embeddingZilliz
 
Developer Data Modeling Mistakes: From Postgres to NoSQL
Developer Data Modeling Mistakes: From Postgres to NoSQLDeveloper Data Modeling Mistakes: From Postgres to NoSQL
Developer Data Modeling Mistakes: From Postgres to NoSQLScyllaDB
 
Are Multi-Cloud and Serverless Good or Bad?
Are Multi-Cloud and Serverless Good or Bad?Are Multi-Cloud and Serverless Good or Bad?
Are Multi-Cloud and Serverless Good or Bad?Mattias Andersson
 
Integration and Automation in Practice: CI/CD in Mule Integration and Automat...
Integration and Automation in Practice: CI/CD in Mule Integration and Automat...Integration and Automation in Practice: CI/CD in Mule Integration and Automat...
Integration and Automation in Practice: CI/CD in Mule Integration and Automat...Patryk Bandurski
 
Vector Databases 101 - An introduction to the world of Vector Databases
Vector Databases 101 - An introduction to the world of Vector DatabasesVector Databases 101 - An introduction to the world of Vector Databases
Vector Databases 101 - An introduction to the world of Vector DatabasesZilliz
 
Human Factors of XR: Using Human Factors to Design XR Systems
Human Factors of XR: Using Human Factors to Design XR SystemsHuman Factors of XR: Using Human Factors to Design XR Systems
Human Factors of XR: Using Human Factors to Design XR SystemsMark Billinghurst
 
"Debugging python applications inside k8s environment", Andrii Soldatenko
"Debugging python applications inside k8s environment", Andrii Soldatenko"Debugging python applications inside k8s environment", Andrii Soldatenko
"Debugging python applications inside k8s environment", Andrii SoldatenkoFwdays
 
Powerpoint exploring the locations used in television show Time Clash
Powerpoint exploring the locations used in television show Time ClashPowerpoint exploring the locations used in television show Time Clash
Powerpoint exploring the locations used in television show Time Clashcharlottematthew16
 
Gen AI in Business - Global Trends Report 2024.pdf
Gen AI in Business - Global Trends Report 2024.pdfGen AI in Business - Global Trends Report 2024.pdf
Gen AI in Business - Global Trends Report 2024.pdfAddepto
 
Tampa BSides - Chef's Tour of Microsoft Security Adoption Framework (SAF)
Tampa BSides - Chef's Tour of Microsoft Security Adoption Framework (SAF)Tampa BSides - Chef's Tour of Microsoft Security Adoption Framework (SAF)
Tampa BSides - Chef's Tour of Microsoft Security Adoption Framework (SAF)Mark Simos
 
CloudStudio User manual (basic edition):
CloudStudio User manual (basic edition):CloudStudio User manual (basic edition):
CloudStudio User manual (basic edition):comworks
 
Streamlining Python Development: A Guide to a Modern Project Setup
Streamlining Python Development: A Guide to a Modern Project SetupStreamlining Python Development: A Guide to a Modern Project Setup
Streamlining Python Development: A Guide to a Modern Project SetupFlorian Wilhelm
 
Artificial intelligence in cctv survelliance.pptx
Artificial intelligence in cctv survelliance.pptxArtificial intelligence in cctv survelliance.pptx
Artificial intelligence in cctv survelliance.pptxhariprasad279825
 
Designing IA for AI - Information Architecture Conference 2024
Designing IA for AI - Information Architecture Conference 2024Designing IA for AI - Information Architecture Conference 2024
Designing IA for AI - Information Architecture Conference 2024Enterprise Knowledge
 
Connect Wave/ connectwave Pitch Deck Presentation
Connect Wave/ connectwave Pitch Deck PresentationConnect Wave/ connectwave Pitch Deck Presentation
Connect Wave/ connectwave Pitch Deck PresentationSlibray Presentation
 
DevoxxFR 2024 Reproducible Builds with Apache Maven
DevoxxFR 2024 Reproducible Builds with Apache MavenDevoxxFR 2024 Reproducible Builds with Apache Maven
DevoxxFR 2024 Reproducible Builds with Apache MavenHervé Boutemy
 
AI as an Interface for Commercial Buildings
AI as an Interface for Commercial BuildingsAI as an Interface for Commercial Buildings
AI as an Interface for Commercial BuildingsMemoori
 
SAP Build Work Zone - Overview L2-L3.pptx
SAP Build Work Zone - Overview L2-L3.pptxSAP Build Work Zone - Overview L2-L3.pptx
SAP Build Work Zone - Overview L2-L3.pptxNavinnSomaal
 
Bun (KitWorks Team Study 노별마루 발표 2024.4.22)
Bun (KitWorks Team Study 노별마루 발표 2024.4.22)Bun (KitWorks Team Study 노별마루 발표 2024.4.22)
Bun (KitWorks Team Study 노별마루 발표 2024.4.22)Wonjun Hwang
 

Dernier (20)

"ML in Production",Oleksandr Bagan
"ML in Production",Oleksandr Bagan"ML in Production",Oleksandr Bagan
"ML in Production",Oleksandr Bagan
 
Training state-of-the-art general text embedding
Training state-of-the-art general text embeddingTraining state-of-the-art general text embedding
Training state-of-the-art general text embedding
 
Developer Data Modeling Mistakes: From Postgres to NoSQL
Developer Data Modeling Mistakes: From Postgres to NoSQLDeveloper Data Modeling Mistakes: From Postgres to NoSQL
Developer Data Modeling Mistakes: From Postgres to NoSQL
 
Are Multi-Cloud and Serverless Good or Bad?
Are Multi-Cloud and Serverless Good or Bad?Are Multi-Cloud and Serverless Good or Bad?
Are Multi-Cloud and Serverless Good or Bad?
 
Integration and Automation in Practice: CI/CD in Mule Integration and Automat...
Integration and Automation in Practice: CI/CD in Mule Integration and Automat...Integration and Automation in Practice: CI/CD in Mule Integration and Automat...
Integration and Automation in Practice: CI/CD in Mule Integration and Automat...
 
Vector Databases 101 - An introduction to the world of Vector Databases
Vector Databases 101 - An introduction to the world of Vector DatabasesVector Databases 101 - An introduction to the world of Vector Databases
Vector Databases 101 - An introduction to the world of Vector Databases
 
Human Factors of XR: Using Human Factors to Design XR Systems
Human Factors of XR: Using Human Factors to Design XR SystemsHuman Factors of XR: Using Human Factors to Design XR Systems
Human Factors of XR: Using Human Factors to Design XR Systems
 
"Debugging python applications inside k8s environment", Andrii Soldatenko
"Debugging python applications inside k8s environment", Andrii Soldatenko"Debugging python applications inside k8s environment", Andrii Soldatenko
"Debugging python applications inside k8s environment", Andrii Soldatenko
 
Powerpoint exploring the locations used in television show Time Clash
Powerpoint exploring the locations used in television show Time ClashPowerpoint exploring the locations used in television show Time Clash
Powerpoint exploring the locations used in television show Time Clash
 
Gen AI in Business - Global Trends Report 2024.pdf
Gen AI in Business - Global Trends Report 2024.pdfGen AI in Business - Global Trends Report 2024.pdf
Gen AI in Business - Global Trends Report 2024.pdf
 
Tampa BSides - Chef's Tour of Microsoft Security Adoption Framework (SAF)
Tampa BSides - Chef's Tour of Microsoft Security Adoption Framework (SAF)Tampa BSides - Chef's Tour of Microsoft Security Adoption Framework (SAF)
Tampa BSides - Chef's Tour of Microsoft Security Adoption Framework (SAF)
 
CloudStudio User manual (basic edition):
CloudStudio User manual (basic edition):CloudStudio User manual (basic edition):
CloudStudio User manual (basic edition):
 
Streamlining Python Development: A Guide to a Modern Project Setup
Streamlining Python Development: A Guide to a Modern Project SetupStreamlining Python Development: A Guide to a Modern Project Setup
Streamlining Python Development: A Guide to a Modern Project Setup
 
Artificial intelligence in cctv survelliance.pptx
Artificial intelligence in cctv survelliance.pptxArtificial intelligence in cctv survelliance.pptx
Artificial intelligence in cctv survelliance.pptx
 
Designing IA for AI - Information Architecture Conference 2024
Designing IA for AI - Information Architecture Conference 2024Designing IA for AI - Information Architecture Conference 2024
Designing IA for AI - Information Architecture Conference 2024
 
Connect Wave/ connectwave Pitch Deck Presentation
Connect Wave/ connectwave Pitch Deck PresentationConnect Wave/ connectwave Pitch Deck Presentation
Connect Wave/ connectwave Pitch Deck Presentation
 
DevoxxFR 2024 Reproducible Builds with Apache Maven
DevoxxFR 2024 Reproducible Builds with Apache MavenDevoxxFR 2024 Reproducible Builds with Apache Maven
DevoxxFR 2024 Reproducible Builds with Apache Maven
 
AI as an Interface for Commercial Buildings
AI as an Interface for Commercial BuildingsAI as an Interface for Commercial Buildings
AI as an Interface for Commercial Buildings
 
SAP Build Work Zone - Overview L2-L3.pptx
SAP Build Work Zone - Overview L2-L3.pptxSAP Build Work Zone - Overview L2-L3.pptx
SAP Build Work Zone - Overview L2-L3.pptx
 
Bun (KitWorks Team Study 노별마루 발표 2024.4.22)
Bun (KitWorks Team Study 노별마루 발표 2024.4.22)Bun (KitWorks Team Study 노별마루 발표 2024.4.22)
Bun (KitWorks Team Study 노별마루 발표 2024.4.22)
 

OmniVent Motorized Diffuser

  • 1. Motorized Damper/Diffuser Tel. 82-2-523-5161~3 omniventsystem.com
  • 2. OvM Diffuser 2/24 Residential Buildings, Apartment Houses
  • 3. OvM Diffuser 3/24 Office Buildings, Auditoriums, Libraries
  • 4. OvM Diffuser 4/24 New Green Technology is Here!
  • 5. Current Methods ㈜ 옴니벤트 5/24 Traditional Air Conditioning Method
  • 6. Current Methods 6/24 1) Single Zone Air Conditioning System (One Zone Control) Air Return types: • Duct Return • Room Space + Duct Return • Ceiling Space + Duct Return No Independent Zone Control → Constant Energy Consumption
  • 7. Current Methods ㈜ 옴니벤트 7/24 2) Multi Split System (Multi Zone Control) Independent Zone Control ↔ High Installation Cost
  • 8. Current Methods ㈜ 옴니벤트 8/24 3) Individual Multi Duct System (Multi Zone Control) Variation A Independent Zone Control ↔ Unrealistic Ceiling Space Management
  • 9. Current Methods 9/24 3) Individual Multi Duct System (Multi Zone Control) Variation B Utilizing Ceiling space as return path Independent Zone Control, Low Install Cost ↔ Inefficient Air Flow Management
  • 10. Current Methods 10/24 Characteristic of Multi Zone Systems Merits Demerits • Independent • High Install Cost MULTI SPLITs zone control • Difficult to fix • Does not refrigerants leaking need high ceiling space • Need Additional Vent system • Independent • Inefficient Air Flow ALL AIR MULTI DUCT SYSTEM Variation B zone control Control Detail • Less • Low Cooling Efficiency Construction due to common air cost vs. return (variation B) Multi Split • Need High • Ventilation Ceiling Space can be integrated
  • 11. Current Methods 11/24 Current Multi Zone Systems WHAT to improve to meet the consumer needs ? Independent Zone control with • Less Installation cost • Ease of Maintenance • Less Energy Consumption Solution OmniVent Motorized Diffuser
  • 12. New Concept / New Technology 12/24 Introduction to New Technology Economical & Practical Independent Zone Control System with mni- ent otorized
  • 13. New Concept / New Technology 13/24 What is ? All in One Damper & Diffuser with Automatic On/Off Control Air Balancing
  • 14. New Concept / New Technology 14/24 OvM Diffuser Switch on Only Where you need, < All Cost Minimization > •Minimal Installation Cost •Easy and low Maintenance •Automatic Air Balancing •Low Electricity Consumption
  • 15. New Concept / New Technology 15/24 Concept of OmniVent Independent Zone Control
  • 16. New Concept / New Technology 16/24 Concept drawings utilizing OvM Diffuser [ Installed with return air duct ] [ Ceiling space to return air ]
  • 17. New Concept / New Technology 17/24 Applications where Independent Zone control is needed  Spot cooling in Large Open Area  to VAV System
  • 18. OvM Diffuser 18/24 Facts about OvM Diffuser  Install & Maint. Friendly  High Credibility  Significant cost saving  Incremental Adjust. w/ vs. Multi Split complete turn off control  Easy Air Balancing  User Friendly  Super Easy Operation  Neat Ceiling Finish  Easy to check any problem  Environment Friendly  Less Energy Consumption
  • 19. OvM Diffuser ㈜ 옴니벤트 19/24 Facts about OvM Diffuser Air Volume vs. Opening Rates PB Damper OvM Diffuser Linear Air Vol. Control OB Damper 150 Ø Neck AK: 130 cm2
  • 20. OvM Diffuser ㈜ 옴니벤트 20/24 Facts about OvM Diffuser Automatic Air Flow Control Ventilation / Cooling Horizontal Spreads Heating Vertical Discharge
  • 21. OvM Diffuser ㈜ 옴니벤트 21/24 Facts about OvM Diffuser Reliability of Component (Motor) Supplied by “Reili” Low Noise, Low Vibe. Stepping Motor Major Supply to Korean Companies: Exporting to LG Electronics 25 Million per Annum (yr 2008) Worldwide (inc. US) Samsung 20 Million Ungjin Korway 30 Million Swing Louver of Multi Split, Bidet, Micro Wave, Application Washer drain control, Hot water distributor… Error Rates 200 PPM (0.02%) 1% Additional Parts Supply
  • 22. OvM Diffuser ㈜ 옴니벤트 22/24 Facts about OvM Diffuser Comparison with other technology OvMd Diffuser Similar Idea Other Idea Appearance & Inner Structure Japan:6-011177(Mitsubishi) Patent 10-2009-0004403 U.S.: 6,176,777 (E.H.Price) No Patent Placement of Motorized Damper Inside Diffuser Cone Upper Outside of Dish Motor inside Duct Maintenance Easy Difficult Difficult Pressure Big, due to Motor facing Big, due to additional Very small Loss air flow Damper Initial Cost 100% 300% ~ 400% 160% Ease of Can apply ONLY in huge Very Easy Not Practical Installation Duct system 
  • 23. OvM Diffuser ㈜ 옴니벤트 23/24 Facts about OvM Diffuser Comparison with other technology Diffusers using Wax OvM Diffuser • Variable Air Volume control using • Precise & Responsive Air Wax Discharge control • No Air Blocking (complete closing) • Self Opening rate control function • Complete Closure Mode • High Priced • Durability & Credibility
  • 24. S Y S T E M omniventsystem.com
  • 25. Attach Current Methods ㈜ 옴니벤트 #1 Air Flow Management for Multi Duct System Back Variation B Air Flow & Cooling Efficiency  Air supply ducts block ceiling space (return path)  resulting in inefficient energy control Pressure Difference between Rooms  Makes door operation difficult Air Volume Control  Large Control Variation of the conventional dampers makes Air volume control inefficient Diffuser Balancing  Not possible when independent ventilation activated