Preventing Timesheet Fraud Strategies for Ensuring Accuracy and Compliance
Test and Evaluation of Conger LH on USS Theodore Roosevelt CVN 71
1. COMMANDER NAVAL AIR FORCES
ATLANTIC FLEET
N434
TEST AND EVALUATION OF CONGER LH
USS THEODORE ROOSEVELT CVN 71
2. Evaluation of Conger LH lubricant and
corrosion prohibitor
• The product being tested combines the
properties of a lubricant, a rust
prohibitor, and also a water repellent
• It contains no
solvents, CFCs, VOCs, silicone, or propellants
• Is completely non-toxic and safe
– for the environment
– for the people who use it
3. • An extremely corrosive area on our Aircraft
Carriers are the Overflow Boxes
– Hard to access and maintain
– Hinged flapper valve prone to crevice corrosion
– Exposed to Seawater and corrosive gases
– Design results in constant retention of water and
concentration of salts
• Conger LH was applied to the hinged areas in the
overflow box and to the stainless pin as well as the
threaded studs on the void closure
– Several studs were cleaned and others remained with
existing corrosion intact
Evaluation of Conger LH lubricant and
corrosion prohibitor
4. Evaluation of Conger LH lubricant and
corrosion prohibitor
3-137-1-V Overflow Box prior to opening
5. Evaluation of Conger LH lubricant and
corrosion prohibitor
3-137-1-V hinged flapper valve
exhibiting corrosion after less than
one year in service
6. Evaluation of Conger LH lubricant and
corrosion prohibitor
3-137-1-V threaded stud not cleaned
7. Evaluation of Conger LH lubricant and
corrosion prohibitor
3-137-1-V with Conger LH applied to studs
8. Evaluation of Conger LH lubricant and
corrosion prohibitor
3-144-1-V access cover
prior to removal
9. Evaluation of Conger LH lubricant and
corrosion prohibitor
3-144-1-V Access cover removed
10. Evaluation of Conger LH lubricant and
corrosion prohibitor
Conger LH applied to hinge brackets
and hinge pin in 3-144-1-V
11. Evaluation of Conger LH lubricant and
corrosion prohibitor
3-144-1-V Overflow Box
Water Retained In Overflow Box
12. Evaluation of Conger LH lubricant and
corrosion prohibitor
• Representatives from COMNAVAIRLANT N434
Staff will return after one year and again after
3 years to evaluate the performance of the
Conger LH lubricant and corrosion
preventative in these spaces.
• Slide show and a Corrosion Control
Information Management System inspection
report will be generated for these two
overflow boxes.