Technical Information

Proline Prosonic Flow B 200
Ultrasonic flow measuring system
The device for accurate, reliable biogas measurement under
variable process conditions




Application                                              Your benefits
• Reliable measurement of wet biogas, digester gas and   Biogas measurement for a wide range of applications
  landfill gas under low process pressure, low flow      with optional real-time measurement of the biogas
  rates and varying gas compositions.                    methane fraction combined with genuine loop-powered
• The Ultrasonic measuring principle is unaffected by    technology.
  the gas composition.
                                                         Sizing - correct product selection
Device properties:                                       Applicator - the reliable, easy-to-use tool for selecting
• Medium temperature: 0 to 80 °C (32 to 176 °F)          and sizing measuring devices for every application
• Process pressure: max. 10 bar (145 psi)
                                                         Installation - simple and efficient
• Nominal diameter: DN 50 to 200 (2 to 8")
                                                         • Short inlet and outlet runs
• Accuracy:
                                                         • Reduced wiring thanks to loop-powered technology
  – Volume flow: ±1.5 % o.r.
  – Methane: ±2 % abs. (optional)                        Commissioning - reliable and intuitive
• Loop powered transmitter made of aluminum or           Guided parameterization ("Make-it-run" Wizards)
  stainless steel                                        Operation - increased measurement availability
• Graphical local display with operation from the        • Multivariable measurement: volume flow and,
  outside (Touch Control)                                  optionally, methane fraction and temperature
• Communication via 4-20 mA HART                         • No pressure loss
• Ex approvals accepted worldwide: ATEX, IECEx,          • Diagnostic capability
  CCSAUS, NEPSI (intrinsically safe or explosion proof   • Automatic data restore by HistoROM
  design)
                                                         Cost-effective Life Cycle Management by W@M




TI01018D/06/EN/02.12
71196568
Table of contents                                                                                                                    Proline Prosonic Flow B 200



Table of contents


Document information . . . . . . . . . . . . . . . . . . . . . . . . 3                  Process . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Symbols used . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3        Medium temperature range . . . . . . . . . . . . . . . . . . . . . . .            24
                                                                                        Pressure-temperature ratings . . . . . . . . . . . . . . . . . . . . . .          24
Function and system design . . . . . . . . . . . . . . . . . . . . 4                    Flow limit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .    25
                                                                                        Pressure loss . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .     25
Measuring principle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
                                                                                        System pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .       25
Measuring system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
                                                                                        Thermal insulation . . . . . . . . . . . . . . . . . . . . . . . . . . . . .      25

Input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Measured variable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .      6
                                                                                        Mechanical construction . . . . . . . . . . . . . . . . . . . . . 25
                                                                                        Design, dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . .        25
Measuring range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .      6
                                                                                        Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .    31
Operable flow range . . . . . . . . . . . . . . . . . . . . . . . . . . . . .      6
                                                                                        Materials . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   33
Input signal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   7
                                                                                        Process connections . . . . . . . . . . . . . . . . . . . . . . . . . . . .       35

Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Output signal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
                                                                                        Operability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .         35
                                                                                        Operating concept . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Signal on alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
                                                                                        Local operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Load . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
                                                                                        Remote operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Ex connection data . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Low flow cut off . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Galvanic isolation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12         Certificates and approvals . . . . . . . . . . . . . . . . . . . . 37
Protocol-specific data . . . . . . . . . . . . . . . . . . . . . . . . . . . 12         CE mark . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .     37
                                                                                        C-Tick symbol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .       37
Power supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . .          13      Ex approval . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .     37
                                                                                        Pressure Equipment Directive . . . . . . . . . . . . . . . . . . . . . .          38
Terminal assignment . . . . . . . . . . . . . . . . . . . . . . . . . . .          13
                                                                                        Other standards and guidelines . . . . . . . . . . . . . . . . . . . . .          38
Supply voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .       14
Power consumption . . . . . . . . . . . . . . . . . . . . . . . . . . . .          14
Current consumption . . . . . . . . . . . . . . . . . . . . . . . . . . .          14   Ordering information . . . . . . . . . . . . . . . . . . . . . . . . 39
Power supply failure . . . . . . . . . . . . . . . . . . . . . . . . . . . .       14
Electrical connection . . . . . . . . . . . . . . . . . . . . . . . . . . .        15   Application packages . . . . . . . . . . . . . . . . . . . . . . . . 39
Potential equalization . . . . . . . . . . . . . . . . . . . . . . . . . . .       17
                                                                                        Diagnostics functions . . . . . . . . . . . . . . . . . . . . . . . . . . .       39
Terminals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .      17
Cable entries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .      17
Cable specification . . . . . . . . . . . . . . . . . . . . . . . . . . . . .      17   Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Overvoltage protection . . . . . . . . . . . . . . . . . . . . . . . . . .         17   Device-specific accessories . . . . . . . . . . . . . . . . . . . . . . . .       39
                                                                                        Communication-specific accessories . . . . . . . . . . . . . . . . . .            40
                                                                                        Service-specific accessories . . . . . . . . . . . . . . . . . . . . . . . .      41
Performance characteristics . . . . . . . . . . . . . . . . . . . 17                    System components . . . . . . . . . . . . . . . . . . . . . . . . . . . .         41
Reference conditions . . . . . . . . . . . . . . . . . . . . . . . . . . .         17
Maximum measured error . . . . . . . . . . . . . . . . . . . . . . . .             18
Repeatability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .      18   Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
Response time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .        18   Standard documentation . . . . . . . . . . . . . . . . . . . . . . . . . 42
Influence of ambient temperature . . . . . . . . . . . . . . . . . . .             18   Supplementary device-dependent documentation . . . . . . . . . . 42


Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .      19      Registered trademarks . . . . . . . . . . . . . . . . . . . . . . . 42
Mounting location . . . . . . . . . . . . . . . . . . . . . . . . . . . . .        19
Orientation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .      19
Inlet and outlet runs . . . . . . . . . . . . . . . . . . . . . . . . . . . .      20
Special mounting instructions . . . . . . . . . . . . . . . . . . . . . .          21

Environment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Ambient temperature range . . . . . . . . . . . . . . . . . . . . . . .            22
Storage temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . .        23
Degree of protection . . . . . . . . . . . . . . . . . . . . . . . . . . . .       23
Shock resistance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .       23
Vibration resistance . . . . . . . . . . . . . . . . . . . . . . . . . . . .       24
Electromagnetic compatibility (EMC) . . . . . . . . . . . . . . . . .              24



2                                                                                                                                                     Endress+Hauser
Proline Prosonic Flow B 200



                              Document information
Symbols used                  Electrical symbols

                                Symbol         Meaning

                                               Direct current
                                    A0011197   A terminal to which DC voltage is applied or through which direct current flows.

                                               Alternating current
                                    A0011198   A terminal to which alternating voltage is applied or through which alternating current flows.

                                               Direct current and alternating current
                                    A0017381   • A terminal to which alternating voltage or DC voltage is applied.
                                               • A terminal through which alternating current or direct current flows.

                                               Ground connection
                                               A grounded terminal which, as far as the operator is concerned, is grounded via a grounding system.
                                    A0011200


                                               Protective ground connection
                                               A terminal which must be connected to ground prior to establishing any other connections.
                                    A0011199


                                               Equipotential connection
                                               A connection that has to be connected to the plant grounding system: This may be a potential
                                    A0011201
                                               equalization line or a star grounding system depending on national or company codes of practice.



                              Symbols for certain types of information

                                Symbol         Meaning

                                               Allowed
                                               Indicates procedures, processes or actions that are allowed.
                                    A0011182


                                               Preferred
                                               Indicates procedures, processes or actions that are preferred.
                                    A0011183


                                               Forbidden
                                               Indicates procedures, processes or actions that are forbidden.
                                    A0011184


                                               Tip
                                               Indicates additional information.
                                    A0011193


                                               Reference to documentation
                                               Refers to the corresponding device documentation.
                                    A0011194


                                               Reference to page
                                               Refers to the corresponding page number.
                                    A0011195


                                               Reference to graphic
                                               Refers to the corresponding graphic number and page number.
                                    A0011196




                              Symbols in graphics

                                    Symbol                Meaning

                                   1, 2, 3,...            Item numbers
                                     ,   ,     …          Series of steps

                                  A, B, C, ...            Views

                               A-A, B-B, C-C, ...         Sections

                                                          Flow direction
                                               A0013441




Endress+Hauser                                                                                                                                       3
Proline Prosonic Flow B 200



                            Symbol              Meaning

                                                Hazardous area
                              -                 Indicates a hazardous area.
                                     A0011187


                                                Safe area (non-hazardous area)
                              .                 Indicates a non-hazardous area.
                                     A0011188




                      Function and system design
Measuring principle   A Prosonic Flow inline flowmeter measures the flow rate of the passing fluid by using sensor pairs located on
                      opposite sides of the meter body and at an angle so that one of the sensors in the pair is slightly downstream.
                      The design is non-invasive and does not have any moving parts.
                      The flow signal is established by alternating an acoustic signal between the sensor pairs and measuring the
                      time of flight of each transmission. Then utilizing the fact that sound travels faster with the flow versus
                      against the flow, this differential time (D T) can be used to determine the fluids velocity between the sensors.
                      The volume flow rate is established by combining all the flow velocities determined by the sensor pairs with
                      the cross sectional area of the meter body and extensive knowledge about fluid flow dynamics. The design of
                      the sensors and their position ensures that only a short straight run of pipe upstream of the meter is required
                      after typical flow obstructions such as bends in one or two planes.
                      Advance digital signal processing facilitates constant validation of the flow measurement reducing
                      susceptibility to multiphase flow conditions and increases the reliability of the measurement.




                                                                  T1              T1'




                                                                                              DT » e
                                                                                                                                 A0015451




                      Direct measurement of the methane fraction (CH4)
                      The sound velocity, temperature and chemical composition of a gas are directly related to one another. If
                      two of these characteristic quantities are known, the third can be calculated. The higher the gas temperature
                      or the methane fraction, the higher the sound velocity in biogas, for example.
                      Since the measuring device accurately measures both the sound velocity and the current gas temperature,
                      the methane fraction can be calculated directly and displayed on site without the need for an additional
                      measuring instrument .
                      The relative humidity of biogas is usually 100 %. Thus, the water content can be determined by the
                      temperature measurement and can be compensated for.
                      The measuring device is unique in its ability to measure the methane fraction directly, making it possible to
                      monitor the gas flow and gas quality 24/7. In this way, operators of a biogas plant, for example, can react
                      swiftly and specifically to problems in the digestion process.




4                                                                                                                  Endress+Hauser
Proline Prosonic Flow B 200




                                          [ft/s]      [m/s]

                                          1600         500
                                          1450         450
                                                                                                                                            T
                                          1300         400
                                          1150         350
                                          1000         300
                                           850         250
                                           700         200
                                                              0        10       20     30    40     50     60     70     80     90    100 [%]
                                                                                                                                                        A0016160


                              å1       Calculation of the methane fraction [%] based on the sound velocity [m/s (ft/s)] and a temperature T of 40 °C
                                       (104 °F), for example


Measuring system              The device consists of a transmitter and a sensor.
                              One device version is available: compact version, transmitter and sensor form a mechanical unit.

                              Transmitter

                              Prosonic Flow 200                             Materials:
                                                                            • Stainless steel 1.4404/316L
                                                                            • Aluminum coated AlSi10Mg
                                                                            Configuration:
                                                                            • External operation via four-line, illuminated local display with touch control
                                                                              and guided menus ("Make-it-run" wizards) for applications
                                                                 A0013471   • Via operating tools (e.g. FieldCare)



                              Sensor

                              Prosonic Flow B                               • Designed exclusively to measure:
                                                                              – Biogas
                              Single-path version: DN 50 (2"),                – Coal seam gas
                              DN 80 (3")                                      – Air
                                                                              – Methane
                                                                              – Nitrogen
                                                                              – Gas with a very high methane fraction
                                                                            • Range of nominal diameter: DN 50 to 200 (2 to 8")
                                                                            • Materials:
                                                                              – Sensor:
                                                                                Stainless steel 1.4404/316L, cold worked
                                                                                Stainless steel 1.4435/316L, cold worked
                                                                 A0015826
                                                                              – Process connections:
                              Two-path version: DN 100 to 200 (4                Stainless steel 1.4301/304,
                              to 8")                                            Stainless steel 1.4306/304L,
                                                                                Stainless steel 1.4404/316L,
                                                                                Steel S235JR,
                                                                                Carbon steel A105




                                                                 A0015452




Endress+Hauser                                                                                                                                                 5
Proline Prosonic Flow B 200



                      Input
Measured variable     Direct measured variables
                      Volume flow

                      Calculated measured variables
                      • Corrected volume flow
                      • Mass flow

                      Optional measured variables (can be ordered)
                      Order code for "Sensor version", option 2 "Volume flow + Biogas analysis"
                      • Corrected methane volume flow
                      • Energy flow
                      • Methane fraction
                      • Gross calorific value
                      • Wobbe index
                      • Temperature

Measuring range       Standard (Order code for "Calibration Flow", option 1 "Operable flow range 30 : 1")
                         Nominal diameter                      Velocity                            Effective volume flow

                         [mm]         [in]        [m/s]                   [ft/s]          [m3/h]                      [ft3/h]

                          50            2         1 to 30           3.28 to 98.4          9 to 269                 316 to 9 495

                          80            3         1 to 30           3.28 to 98.4         20 to 611                720 to 21 592

                          100           4         1 to 30           3.28 to 98.4        34 to 1 032               1 215 to 36 443

                          150           6         1 to 30           3.28 to 98.4        76 to 2 290               2 695 to 80 862

                          200           8         1 to 30           3.28 to 98.4        131 to 3 925             4 620 to 138 596



                      Optional (Order code for "Calibration Flow", option 2 "Operable flow range 100 : 1")
                         Nominal diameter                       Velocity                             Effective volume flow

                         [mm]         [in]          [m/s]                   [ft/s]           [m3/h]                   [ft3/h]

                          50            2          0.3 to 30          0.98 to 98.4           3 to 269               95 to 9 495

                          80            3          0.3 to 30          0.98 to 98.4           6 to 611             215 to 21 592

                          100           4          0.3 to 30          0.98 to 98.4        11 to 1 032             363 to 36 443

                          150           6          0.3 to 30          0.98 to 98.4        25 to 2 290             805 to 80 862

                          200           8          0.3 to 30          0.98 to 98.4        43 to 3 925            1 365 to 138 596



                      The values in the table should only be regarded as reference values.
                           To calculate the measuring range, use the Applicator sizing tool (® ä 41)


                      Recommended measuring range
                      "Flow limit" section (® ä 25)

Operable flow range   • 30 : 1 (standard; order code for "Calibration Flow", option 1 "Operable flow range 30 : 1")
                      • 100 : 1 (optional; order code for "Calibration Flow", option 2 "Operable flow range 100 : 1")
                      Flow rates above the preset full scale value do not overload the amplifier so the totalized values are
                      registered correctly.




6                                                                                                                    Endress+Hauser
Proline Prosonic Flow B 200



Input signal                  HART protocol
                              To increase the accuracy of certain measured variables, a measured pressure value can be used instead of a
                              fixed process pressure. For this purpose, the measuring device continuously reads in the process pressure
                              from a pressure transmitter (e.g. Cerabar M or Cerabar S) via the HART protocol.
                              The pressure transmitter must support the following protocol-specific functions:
                              • HART protocol
                              • Burst mode
                              • Endress+Hauser recommends the use of an absolute pressure transmitter
                                   • Various pressure transmitters can be ordered from Endress+Hauser: see "Accessories" section
                                     (® ä 41)
                                   • Please comply with the special mounting instructions when using pressure transmitters (® ä 21)
                              External pressure compensation is recommended to calculate the following measured variables:
                              • Corrected volume flow
                              • Corrected methane volume flow
                              • Mass flow
                              • Energy flow




                              Output
Output signal                 Current output

                              Current output 1              4-20 mA HART (passive)

                              Current output 2              4-20 mA (passive)

                              Resolution                    < 1 µA

                              Damping                       Adjustable: 0.07 to 999 s

                              Assignable measured           •   Volume flow
                              variables                     •   Corrected volume flow
                                                            •   Corrected methane volume flow
                                                            •   Mass flow
                                                            •   Energy flow
                                                            •   Methane fraction
                                                            •   Gross calorific value
                                                            •   Wobbe index
                                                            •   Temperature



                              Pulse/frequency/switch output

                              Function                      Can be set to pulse, frequency or switch output

                              Version                       Passive, open collector

                              Maximum input values          • DC 35 V
                                                            • 50 mA
                                                                   For information on the Ex connection values (® ä 10)


                              Voltage drop                  • For £ 2 mA: 2 V
                                                            • For 10 mA: 8 V

                              Residual current              £ 0.05 mA

                              Pulse output

                              Pulse width                   Adjustable: 5 to 2 000 ms

                              Maximum pulse rate            100 Impulse/s

                              Pulse value                   Adjustable




Endress+Hauser                                                                                                                             7
Proline Prosonic Flow B 200



                  Assignable measured           •   Volume flow
                  variables                     •   Corrected volume flow
                                                •   Corrected methane volume flow
                                                •   Mass flow
                                                •   Energy flow

                  Frequency output

                  Output frequency              Adjustable: 0 to 1 000 Hz

                  Damping                       Adjustable: 0 to 999 s

                  Pulse/pause ratio             1:1

                  Assignable measured           •   Volume flow
                  variables                     •   Corrected volume flow
                                                •   Corrected methane volume flow
                                                •   Mass flow
                                                •   Energy flow
                                                •   Methane fraction
                                                •   Gross calorific value
                                                •   Wobbe index
                                                •   Temperature

                  Switch output

                  Switching behavior            Binary, conductive or non-conductive

                  Switching delay               Adjustable: 0 to 100 s

                  Number of switching           Unlimited
                  cycles

                  Assignable functions          • Off
                                                • On
                                                • Diagnostic behavior
                                                • Limit value
                                                  – Volume flow
                                                  – Corrected volume flow
                                                  – Corrected methane volume flow
                                                  – Mass flow
                                                  – Energy flow
                                                  – Methane fraction
                                                  – Gross calorific value
                                                  – Wobbe index
                                                  – Temperature
                                                  – Totalizer 1 to 3
                                                • Flow direction monitoring
                                                • Status
                                                  Low flow cut off


Signal on alarm   Depending on the interface, failure information is displayed as follows:

                  Current output

                  4-20 mA
                  Failure mode                  Selectable (as per NAMUR recommendation NE 43):
                                                • Minimum value: 3.6 mA
                                                • Maximum value: 22 mA
                                                • Defined value: 3.59 to 22.5 mA
                                                • Actual value
                                                • Last valid value



                  HART

                  Device diagnostics            Device condition can be read out via HART Command 48




8                                                                                                            Endress+Hauser
Proline Prosonic Flow B 200



                              Pulse/frequency/switch output

                              Pulse output

                              Failure mode                   Choose from:
                                                             • Actual value
                                                             • No pulses

                              Frequency output

                              Failure mode                   Choose from:
                                                             • Actual value
                                                             • Defined value: 0 to 1 250 Hz
                                                             • 0 Hz

                              Switch output

                              Failure mode                   Choose from:
                                                             • Current status
                                                             • Open
                                                             • Closed



                              Local display

                              Plain text display             With information on cause and remedial measures

                              Backlight                      Additionally for device version with SD03 local display: red lighting indicates a device
                                                             error.



                                   Status signal as per NAMUR recommendation NE 107


                              Operating tool
                              • Via digital communication:
                                HART protocol
                              • Via service interface

                              Plain text display             With information on cause and remedial measures



                                   Additional information on remote operation (® ä 36)


Load                          Load for current output: 0 to 500 W, depending on the external supply voltage of the power supply unit

                              Calculation of the maximum load
                              Depending on the supply voltage of the power supply unit (US), the maximum load (RB) including line
                              resistance must be observed to ensure adequate terminal voltage at the device. In doing so, observe the
                              minimum terminal voltage (® ä 14)
                              • For US = 16.0 to 16.8 V: RB £ (US - 16.0 V) : 0.0036 A
                              • For US = 16.8 to 23.0 V: RB £ (US - 12.0 V) : 0.022 A
                              • For US = 23.0 to 30.0 V: RB £ 500 W




Endress+Hauser                                                                                                                                          9
Proline Prosonic Flow B 200




                                  Rb [W]
                                                                           1                  1.1              1.2
                                  600

                                  500

                                  400

                                  300
                            220
                                  200
                                  100

                                    0
                                        14   16   18        20        22        24    26      28    30    32     34        36       Us [V]
                                               16.8                        23                                         35
                                                                                                                                             A0018972


                     1   Operating range
                     1.1 For order code for "Output", option A "4-20 mA HART"/option B "4-20 mA HART, pulse/frequency/switch
                         output" with Ex i and option C "4-20 mA HART, 4-20 mA"
                     1.2 For order code for "Output", option A "4-20 mA HART"/option B "4-20 mA HART, pulse/frequency/switch
                         output" with non-Ex and Ex d


                     Sample calculation
                     Supply voltage of the power supply unit: US = 17.5 V
                     Maximum load: RB £ (17.5 V - 12.0 V) : 0.022 A = 250 W

Ex connection data   Safety-related values

                     Ex d type of protection

                                Order code for                                  Output type                     Safety-related values
                                  "Output"

                     Option A                                 4-20mA HART                                Unom = DC 35 V
                                                                                                         Umax = 250 V

                     Option B                                 4-20mA HART                                Unom = DC 35 V
                                                                                                         Umax = 250 V

                                                              Pulse/frequency/switch output              Unom = DC 35 V
                                                                                                         Umax = 250 V
                                                                                                         Pmax = 1 W 1)

                     1)    Internal circuit limited by Ri = 760.5 W

                     Option C                                 • 4-20mA HART                              Unom = DC 30 V
                                                              • 4-20mA                                   Umax = 250 V


                     Type of protection XP

                                Order code for                                  Output type                     Safety-related values
                                  "Output"

                     Option A                                 4-20mA HART                                Unom = DC 35 V
                                                                                                         Umax = 250 V

                     Option B                                 4-20mA HART                                Unom = DC 35 V
                                                                                                         Umax = 250 V

                                                              Pulse/frequency/switch output              Unom = DC 35 V
                                                                                                         Umax = 250 V
                                                                                                         Pmax = 1 W 1)

                     1)    Internal circuit limited by Ri = 760.5 W




10                                                                                                                              Endress+Hauser
Proline Prosonic Flow B 200



                              Option C                    • 4-20mA HART                   Unom = DC 30 V
                                                          • 4-20mA                        Umax = 250 V


                              Type of protection NI

                                         Order code for              Output type                Safety-related values
                                           "Output"

                              Option A                    4-20mA HART                     Unom = DC 35 V

                              Option B                    4-20mA HART                     Unom = DC 35 V

                                                          Pulse/frequency/switch output   Unom = DC 35 V

                              Option C                    • 4-20mA HART                   Unom = DC 30 V
                                                          • 4-20mA


                              Type of protection NIFW

                                         Order code for              Output type               Intrinsically safe values
                                           "Output"

                              Option A                    4-20mA HART                     Ui = DC 35 V
                                                                                          Ii = n.a.
                                                                                          Pi = 1 W
                                                                                          Li = 0 mH
                                                                                          Ci = 5 nF

                              Option B                    4-20mA HART                     Ui = DC 35 V
                                                                                          Ii = n.a.
                                                                                          Pi = 1 W
                                                                                          Li = 0 mH
                                                                                          Ci = 5 nF

                                                          Pulse/frequency/switch output   Ui = DC 35 V
                                                                                          Ii = n.a.
                                                                                          Pi = 1 W
                                                                                          Li = 0 mH
                                                                                          Ci = 6 nF

                              Option C                    • 4-20mA HART                   Ui = DC 30 V
                                                          • 4-20mA                        Ii = n.a.
                                                                                          Pi = 1 W
                                                                                          Li = 0 mH
                                                                                          Ci = 30 nF


                              Intrinsically safe values

                              type of protection Ex ia

                                         Order code for              Output type               Intrinsically safe values
                                           "Output"

                              Option A                    4-20mA HART                     Ui = DC 30 V
                                                                                          Ii = 300 mA
                                                                                          Pi = 1 W
                                                                                          Li = 0 mH
                                                                                          Ci = 5 nF




Endress+Hauser                                                                                                             11
Proline Prosonic Flow B 200



                         Option B                               4-20mA HART                     Ui = DC 30 V
                                                                                                Ii = 300 mA
                                                                                                Pi = 1 W
                                                                                                Li = 0 mH
                                                                                                Ci = 5 nF

                                                                Pulse/frequency/switch output   Ui = DC 30 V
                                                                                                Ii = 300 mA
                                                                                                Pi = 1 W
                                                                                                Li = 0 mH
                                                                                                Ci = 6 nF

                         Option C                               • 4-20mA HART                   Ui = DC 30 V
                                                                • 4-20mA                        Ii = 300 mA
                                                                                                Pi = 1 W
                                                                                                Li = 0 mH
                                                                                                Ci = 30 nF


                         IS type of protection

                                    Order code for                         Output type               Intrinsically safe values
                                      "Output"

                         Option A                               4-20mA HART                     Ui = DC 30 V
                                                                                                Ii = 300 mA
                                                                                                Pi = 1 W
                                                                                                Li = 0 mH
                                                                                                Ci = 5 nF

                         Option B                               4-20mA HART                     Ui = DC 30 V
                                                                                                Ii = 300 mA
                                                                                                Pi = 1 W
                                                                                                Li = 0 mH
                                                                                                Ci = 5 nF

                                                                Pulse/frequency/switch output   Ui = DC 30 V
                                                                                                Ii = 300 mA
                                                                                                Pi = 1 W
                                                                                                Li = 0 mH
                                                                                                Ci = 6 nF

                         Option C                               • 4-20mA HART                   Ui = DC 30 V
                                                                • 4-20mA                        Ii = 300 mA
                                                                                                Pi = 1 W
                                                                                                Li = 0 mH
                                                                                                Ci = 30 nF


Low flow cut off         The switch points for low flow cut off are user-selectable.

Galvanic isolation       All outputs are galvanically isolated from one another.

Protocol-specific data   HART

                         Manufacturer ID                  0x11

                         Device type ID                   0x5A

                         HART protocol revision           6.0

                         Device description files (DTM, Information and files under:
                         DD)                            www.endress.com




12                                                                                                               Endress+Hauser
Proline Prosonic Flow B 200



                              HART load                         • Min. 250 Ω
                                                                • Max. 500 W

                              Dynamic variables                 The measured variables can be freely assigned to the dynamic variables.
                                                                Measured variables for PV (primary dynamic variable)
                                                                • Volume flow
                                                                • Corrected volume flow
                                                                • Corrected methane volume flow
                                                                • Mass flow
                                                                • Energy flow
                                                                • Methane fraction
                                                                • Gross calorific value
                                                                • Wobbe index
                                                                • Temperature


                                                                Measured variables for SV, TV, QV (secondary, tertiary and quaternary
                                                                dynamic variable)
                                                                • Volume flow
                                                                • Corrected volume flow
                                                                • Corrected methane volume flow
                                                                • Mass flow
                                                                • Energy flow
                                                                • Methane fraction
                                                                • Gross calorific value
                                                                • Wobbe index
                                                                • Temperature
                                                                • Totalizer 1
                                                                • Totalizer 2
                                                                • Totalizer 3




                              Power supply
Terminal assignment           Transmitter

                              Connection versions

                                                  2       1           3                                       2           1          3




                                                 + –      + –
                                                 3 4      1 2                                                + –        + –
                                                                                                             3 4        1 2
                                                                                     A0013570                                                     A0018161


                              Maximum number of terminals, without integrated                   Maximum number of terminals, with integrated
                              overvoltage protection                                            overvoltage protection

                              1     Output 1 (passive): supply voltage and signal transmission
                              2     Output 2 (passive): supply voltage and signal transmission
                              3     Ground terminal for cable shield



                                        Order code for                                              Terminal numbers
                                          "Output"
                                                                                   Output 1                                   Output 2

                                                                           1 (+)                  2 (-)              3 (+)                4 (-)

                                            Option A                       4-20 mA HART (passive)                                -

                                            Option B 1)                    4-20 mA HART (passive)                  Pulse/frequency/switch output
                                                                                                                              (passive)




Endress+Hauser                                                                                                                                        13
Proline Prosonic Flow B 200



                                     Option C 1)                      4-20 mA HART (passive)                      4-20 mA (passive)


                       1)   Output 1 must always be used; output 2 is optional.


Supply voltage         An external power supply is required for each output. The following supply voltage values apply for the 4-20
                       mA and 4-20 mA HART current output:

                                 Order code for                              Minimum                                 Maximum
                                   "Output"                               terminal voltage                        terminal voltage

                       • Option A 1), 2): 4-20 mA HART         For 4 mA: ³ DC 16 V                      DC 35 V
                       • Option B 1), 2): 4-20 mA HART,        For 20 mA: ³ DC 12 V
                         Pulse/frequency/switch output

                       Option C 1), 2): 4-20 mA HART,          For 4 mA: ³ DC 16 V                      DC 30 V
                       4-20 mA                                 For 20 mA: ³ DC 12 V


                       1)   External supply voltage of the power supply unit with load (® ä 9)
                       2)   For device versions with local display SD03: The terminal voltage must be increased by DC 2 V if backlighting is
                            used.
                            For information on the Ex connection values (® ä 10)

                            Various power supply units can be ordered from Endress+Hauser: see "Accessories" section
                            (® ä 41)

Power consumption      Transmitter
                                            Order code for                                       Maximum power consumption
                                              "Output"

                       Option A: 4-20 mA HART                                       770 mW

                       Option B: 4-20 mA HART,                                      • Operation with output 1: 770 mW
                       Pulse/frequency/switch output                                • Operation with output 1 and 2: 2 770 mW

                       Option C: 4-20 mA HART, 4-20 mA                              • Operation with output 1: 660 mW
                                                                                    • Operation with output 1 and 2: 1 320 mW

                            For information on the Ex connection values (® ä 10)


Current consumption    Current output
                       For every 4-20 mA or 4-20 mA HART current output: 3.6 to 22.5 mA
                            If the option Defined value is selected in the Failure mode parameter (® ä 8): 3.59 to 22.5 mA


Power supply failure   • Totalizers stop at the last value measured.
                       • Configuration is retained in the device memory (HistoROM).
                       • Error messages (incl. total operated hours) are stored.




14                                                                                                                         Endress+Hauser
Proline Prosonic Flow B 200



Electrical connection         Connecting the transmitter



                                                                   2



                                                                    1




                                                                                                                               A0015510


                              1    Cable entry for output 1
                              2    Cable entry for output 2


                              Connection examples


                                               1                        2        3     4        5              6

                                                                                                           4...20 mA
                                                                            +                                          +
                                                                                                                           7
                                                                            -                                          -




                                                                                                                               A0015511


                              å2      Connection example for 4-20 mA HART current output (passive)
                              1    Automation system with current input (e.g. PLC)
                              2    Active barrier for power supply (e.g. RN221N) (® ä 17)
                              3    Observe cable specification (® ä 17)
                              4    Resistor for HART communication (³ 250 W): observe maximum load (® ä 9)
                              5    Connection for HART operating devices (® ä 36)
                              6    Analog display unit: observe maximum load (® ä 9)
                              7    Transmitter



                                               1                        2                           3


                                                        +                                               4...20 mA
                                                                            +                                          +
                                                                                                                           4
                                                                            -                                          -
                                                        –




                                                                                                                               A0015512


                              å3      Connection example for 4-20 mA current output (passive)
                              1    Automation system with current input (e.g. PLC)
                              2    Active barrier for power supply (e.g. RN221N) (® ä 14)
                              3    Analog display unit: observe maximum load (® ä 9)
                              4    Transmitter




Endress+Hauser                                                                                                                    15
Proline Prosonic Flow B 200




                      1                                                 2
                                                     –   +

                               _                                                                     +
                                                                                                     –    3
                               +
               12345
                                                                                                              A0016801


     å4      Connection example for pulse/frequency output (passive)
     1    Automation system with pulse/frequency input (e.g. PLC)
     2    Power supply
     3    Transmitter: Observe input values (® ä 7)




                     1                                              2
                                                     _ +
                              _
                                                                                                     +
                                                                                                     _   3
                              +

                                                                                                              A0016802


     å5      Connection example for switch output (passive)
     1    Control system with switch input (e.g. PLC)
     2    Power supply
     3    Transmitter: Observe input values (® ä 7)



                      1                          2                  3           4      5

                                                                                    4...20 mA
                                                              +             +
                                                                                                    +
                                                              –             –                            7
                              +                                                                     -
                              –
                              –
                              +
                                                              +             +
                                                                                                    +
                                                              –             –                            6
                                                                                                    -




                                                         3                      4
                                                                                                              A0016029


     å6      Connection example for HART input with a common negative
     1    Automation system with HART output (e.g. PLC)
     2    Resistor for HART communication (³ 250 W): observe maximum load (® ä 9)
     3    Active barrier for power supply (e.g. RN221N) (® ä 14)
     4    Observe cable specification (® ä 17)
     5    Analog display unit: observe maximum load (® ä 9)
     6    Pressure transmitter (e.g. Cerabar M, Cerabar S): see requirements (® ä 7)
     7    Transmitter



16                                                                                                 Endress+Hauser
Proline Prosonic Flow B 200



Potential equalization        No special measures for potential equalization are required.
                                      For devices in hazardous locations, please observe the guidelines in the Ex documentation (XA).


Terminals                     • For device version without integrated overvoltage protection: plug-in spring terminals for wire cross-
                                sections 0.5 to 2.5 mm2 (20 to 14 AWG)
                              • For device version with integrated overvoltage protection: screw terminals for wire cross-sections
                                0.2 to 2.5 mm2 (24 to 14 AWG)

Cable entries                 • Cable gland (not for Ex d): M20 × 1.5 with cable Æ 6 to 12 mm (0.24 to 0.47 in)
                              • Thread for cable entry:
                                – For non-Ex and Ex: NPT ½"
                                – For non-Ex and Ex (not for CSA Ex d/XP): G ½"
                                – For Ex d: M20 × 1.5

Cable specification           Permitted temperature range
                              • –40 °C (–40 °F)...³ 80 °C (176 °F)
                              • Minimum requirement: cable temperature range ³ ambient temperature + 20 K

                              Signal cable

                              Current output
                              • For 4-20 mA: standard installation cable is sufficient.
                              • For 4-20 mA HART: Shielded cable recommended. Observe grounding concept of the plant.

                              Pulse/frequency/switch output
                              Standard installation cable is sufficient.

Overvoltage protection        The device can be ordered with integrated overvoltage protection for diverse approvals:
                              Order code for "Accessory mounted", option NA "overvoltage protection"

                              Input voltage range                       Values correspond to supply voltage specifications (® ä 14) 1)

                              Resistance per channel                    2 × 0.5 W max

                              DC sparkover voltage                      400 to 700 V

                              Trip surge voltage                        < 800 V

                              Capacitance at 1 MHz                      < 1.5 pF

                              Nominal discharge current (8/20           10 kA
                              ms)

                              Temperature range                         –40 to +85 °C (–40 to +185 °F)

                              1)      The voltage is reduced by the amount of the internal resistance Imin × Ri


                                      Depending on the temperature class, restrictions apply to the ambient temperature for device versions
                                      with overvoltage protection .




                              Performance characteristics
Reference conditions          •    Error limits following ISO/DIS 11631
                              •    Calibration gas: air
                              •    Temperature regulated to 24 ± 0.5 °C (75.2 ± 0.9 °F) under atmospheric pressure
                              •    Humidity regulated to < 40 % RH
                              •    Accuracy based on accredited calibration rigs that are traced to ISO 17025.
                                      To calculate the measuring range, use the Applicator sizing tool (® ä 41)



Endress+Hauser                                                                                                                           17
Proline Prosonic Flow B 200



Maximum measured error   In addition to the values indicated, the measured error at the current output is typically ±4 mA.
                         o.r. = of reading; o.f.s. = of full scale value; abs. = absolute; 1 g/cm3 = 1 kg/l; T = medium temperature
                         Volume flow

                         Standard                                                   • ±1.5 % o.r. for 3 to 30 m/s (9.84 to 98.4 ft/s)
                         Order code for "Calibration", option 1                     • ±3 % o.r. for 1 to 3 m/s (3.28 to 9.84 ft/s)

                         Optional                                                   • ±0.1 % o.f.s. for 0.3 to 1 m/s (0.98 to 3.28 ft/s)
                         Order code for "Calibration", option 2                     • ±1.5 % o.r. for 1 to 30 m/s (3.28 to 98.4 ft/s)



                         Methane
                         ±2 % o.f.s. = ±2 % abs.
                         Temperature
                         ±0.6 °C ± 0.005 × T °C (±0.9 °F ± 0.005 × (T – 32) °F)

                         Example for max. measured error (volume flow)


                               [%]
                             10.0
                               9.0
                               8.0                         2
                               7.0
                               6.0                                             1
                               5.0
                               4.0
                               3.0
                               2.0
                               1.0
                                 0
                                     0        1        2          3        4        5         6        7        8                30        [m/s]
                                                                                                                                             v
                                     0            5               10           15            20            25                      100     [ft/s]
                                                                                                                                                A0015541


                         å7       Example for max. measured error (volume flow) in % o.r.
                         1    Standard (order code for "Calibration", option 1)
                         2    Optional (order code for "Calibration", option 2)


Repeatability            o.r. = of reading; o.f.s. = of full scale value; abs. = absolute; 1 g/cm3 = 1 kg/l; T = medium temperature

                         Volume flow
                         ±0.5 % o.r.
                         Methane
                         ±0.5 % o.f.s. = ±0.5 % abs.
                         Temperature
                         ±0.3 °C ± 0.0025 × T °C (±0.45 °F ± 0.0025 × (T – 32) °F)

Response time            • The response time depends on the configuration (damping).
                         • Response time in the event of erratic changes in the flow: after 1 000 ms 95 % of the full scale value.

Influence of ambient     o.r. = of reading; o.f.s. = of full scale value
temperature
                         Current output
                         Additional error, in relation to the span of 16 mA:




18                                                                                                                                Endress+Hauser
Proline Prosonic Flow B 200



                              Temperature coefficient at         0.02 %/10 K, max. 0.35 % over the entire temperature range
                              zero point (4 mA)                  –40 to +60 °C (–40 to +140 °F)

                              Temperature coefficient            0.05 %/10 K, max. 0.5 % over the entire temperature range
                              with span (20 mA)                  –40 to +60 °C (–40 to +140 °F)



                              Pulse/frequency output

                              Temperature coefficient            Max. ±100 ppm o.r.




                              Installation
                              No special measures such as supports are necessary. External forces are absorbed by the construction of the
                              device.

Mounting location




                                                                                                                                              A0015543




Orientation                   The direction of the arrow on the sensor helps you to install the sensor according to the flow direction
                              (direction of medium flow through the piping).
                                      • Install the measuring device in a parallel plane free of external mechanical stress.
                                      • The internal diameter of the pipe must match the internal diameter of the sensor (® ä 26).




                                                                                                                                              A0015895




                                                                        Orientation                                              Compact version

                                  A       Vertical orientation




                                                                                                                      A0015545


                                  B       Horizontal orientation, transmitter head
                                          up *

                                                                                                                      A0015589




Endress+Hauser                                                                                                                                     19
Proline Prosonic Flow B 200



                                                                  Orientation                                              Compact version

                            C       Horizontal orientation, transmitter head
                                    down *

                                                                                                                A0015590


                            D       Horizontal orientation, transmitter head
                                    at side
                                                                                                                A0015592




                                * A maximum deviation of only ±3 ° is permitted for the horizontal alignment of the transducers.



                                                                                                      –3°
                                                                                         0°
                                                                               –3°                    +3°
                                                                0°
                                                                               +3°

                                                                                                                                        A0016534




Inlet and outlet runs   The sensor should be mounted upstream of assemblies such as valves, T-sections, elbows etc. where
                        possible. As a minimum, the inlet and outlet runs shown below must be observed to achieve the specific
                        accuracy of the device. The longest inlet run shown must be observed if two or more flow disturbances are
                        present.

                        Single-path version: DN 50 (2"), DN 80 (3")


                                     A                                                        B
                                                1                      2                               1                     2

                                            20 × DN                  3 × DN                         20 × DN                3 × DN


                                     C                                                        D
                                                1                      2                               1                     2

                                            20 × DN                  3 × DN                         20 × DN                3 × DN

                                                                                                                                        A0015453


                        å8        Single-path version: minimum inlet and outlet runs with various flow obstructions
                        A    90 ° elbow or T-section
                        B    Pump
                        C    2× 90 ° elbow 3-dimensional
                        D    Control valve
                        1    Inlet run
                        2    Outlet run




20                                                                                                                          Endress+Hauser
Proline Prosonic Flow B 200



                                Two-path version: DN 100 to 200 (4 to 8")


                                           A                                                    B
                                                        1                   2                                1                      2

                                                   10 × DN                3 × DN                         10 × DN              3 × DN


                                           C                                                    D
                                                        1                   2                                1                      2

                                                   10 × DN                3 × DN                         10 × DN              3 × DN

                                                                                                                                            A0015553


                                å9      Two-path version: minimum inlet and outlet runs with various flow obstructions
                                A    90 ° elbow or T-section
                                B    Pump
                                C    2× 90 ° elbow 3-dimensional
                                D    Control valve
                                1    Inlet run
                                2    Outlet run


Special mounting instructions   Outlet run for pressure transmitter
                                If a pressure transmitter is installed downstream of the measuring device, make sure there is sufficient
                                distance between the two devices.



                                                                                                        PT



                                                                                             3 × DN

                                                                                                                                            A0015901


                                PT   Pressure transmitter


                                Flow conditioner
                                It is advisable to use a flow conditioner if the inlet runs cannot be observed. Using a flow conditioner
                                reduces the inlet required as follows:

                                                    Single-path version                                          Two-path version

                                                            10 × DN                                                  5 × DN



                                The flow conditioner should be installed so that it divides the available inlet run by a ratio of roughly 20 : 80.
                                Example for an inlet run of 10 × DN:


                                                                      1


                                                                 2 × DN                8 × DN
                                                                                   10 × DN
                                                                                                                                            A0015562


                                1    Flow conditioner




Endress+Hauser                                                                                                                                 21
Proline Prosonic Flow B 200



                            Pressure loss
                            The pressure loss for flow conditioners is calculated as follows:
                            Dp [mbar] = 0.0085 · r [kg/m3] · v2 [m/s]

                            Example for biogas
                            p = 1 040 mbar abs.
                            r = 1.0432 kg/m3 at t = 54 °C (129 °F)
                            v = 7 m/s
                            Dp = 0.0085 · 1.0432 kg/m3 · 49 m/s = 0.434 mbar

                            ---
                            abs.: absolute
                            r: density of the process medium
                            v: average flow velocity




                            Environment
Ambient temperature range   Transmitter                           –40 to +60 °C (–40 to +140 °F)

                            Local display                         –20 to +60 °C (–4 to +140 °F), the readability of the display may be impaired
                                                                  at temperatures outside the temperature range.

                            Sensor                                • Flange material carbon steel: –10 to +60 °C (+14 to +140 °F)
                                                                  • Flange material stainless steel: –40 to +60 °C (–40 to +140 °F)
                                                                  • Version without flange: –40 to +60 °C (–40 to +140 °F)



                            ►    If operating outdoors:
                                 Avoid direct sunlight, particularly in warm climatic regions.

                                 Weather protection covers can be ordered from Endress+Hauser: see "Accessories" section (® ä 39)


                            Temperature tables
                            The following interdependencies between the permitted ambient and fluid temperatures apply when
                            operating the device in hazardous areas:
                            The following applies for installations with overvoltage protection in conjunction with approval code BJ or IJ:
                            Ta = Ta - 2 °C (Ta = Ta - 3.6 °F)
                            Order code for "Output", option A "4-20mA HART"
                            Ex ia, Ex d, CCSAUS IS, CCSAUS XP, CCSAUS NI

                            SI units
                                Nominal diameter         Ta       T6           T5            T4            T3             T2             T1
                                     [mm]               [°C]    [85 °C]     [100 °C]      [135 °C]      [200 °C]       [300 °C]       [450 °C]

                                       50 to 200         40       60           80            80             80            80             80

                                       50 to 200         50        –           80            80             80            80             80

                                       50 to 200         60        –           80            80             80            80             80



                            US units
                                Nominal diameter         Ta        T6           T5            T4            T3             T2            T1
                                     [in]               [°F]    [185 °F]     [212 °F]      [275 °F]      [392 °F]       [572 °F]      [842 °F]

                                        2 to 8          104       140           176             176         176           176           176

                                        2 to 8          122        –            176             176         176           176           176

                                        2 to 8          140        –            176             176         176           176           176




22                                                                                                                             Endress+Hauser
Proline Prosonic Flow B 200



                              Order code for "Output", option B "4-20mA HART, pulse/frequency/switch output"
                              Ex ia, Ex d, CCSAUS IS, CCSAUS XP, CCSAUS NI

                              SI units
                                   Nominal diameter        Ta        T6           T5               T4          T3         T2         T1
                                        [mm]              [°C]     [85 °C]     [100 °C]         [135 °C]    [200 °C]   [300 °C]   [450 °C]

                                         50 to 200         40        – 1)         80              80          80         80         80
                                                                                       2)
                                         50 to 200         50         –           60              80          80         80         80

                                         50 to 200         60         –            –              80          80         80         80

                              1)     Ta = 60 °C for pulse/frequency/switch output Pi £ 0.85 W
                              2)     Ta = 80 °C for pulse/frequency/switch output Pi £ 0.85 W


                              US units
                                   Nominal diameter         Ta        T6            T5              T4         T3         T2         T1
                                        [in]               [°F]    [185 °F]      [212 °F]        [275 °F]   [392 °F]   [572 °F]   [842 °F]

                                          2 to 8           104        – 1)         176             176        176        176        176

                                          2 to 8           122         –          140 2)           176        176        176        176

                                          2 to 8           140         –               –           176        176        176        176

                              1)     Ta = 140 °F for pulse/frequency/switch output Pi £ 0.85 W
                              2)     Ta = 176 °F for pulse/frequency/switch output Pi £ 0.85 W


                              Order code for "Output", option C "4-20mA HART, 4-20mA"
                              Ex ia, Ex d, CCSAUS IS, CCSAUS XP, CCSAUS NI

                              SI units
                                   Nominal diameter        Ta        T6           T5               T4          T3         T2         T1
                                        [mm]              [°C]     [85 °C]     [100 °C]         [135 °C]    [200 °C]   [300 °C]   [450 °C]

                                         50 to 200         40        60           80              80          80         80         80

                                         50 to 200         50         –           80              80          80         80         80

                                         50 to 200         60         –           55              80          80         80         80



                              US units
                                   Nominal diameter         Ta        T6            T5              T4         T3         T2         T1
                                        [in]               [°F]    [185 °F]      [212 °F]        [275 °F]   [392 °F]   [572 °F]   [842 °F]

                                          2 to 8           104       140           176             176        176        176        176

                                          2 to 8           122         –           176             176        176        176        176

                                          2 to 8           140         –           131             176        176        176        176


Storage temperature           –40 to +80 °C (–40 to +176 °F), preferably at +20 °C (+68 °F)

Degree of protection          Transmitter
                              • As standard: IP66/67, type 4X enclosure
                              • When housing is open: IP20, type 1 enclosure
                              • Display module: IP22, type 1 enclosure
                              Sensor
                              IP66/67, type 4X enclosure

Shock resistance              In accordance with EN 60721-3-4




Endress+Hauser                                                                                                                            23
Proline Prosonic Flow B 200



Vibration resistance            Class 4M4, in accordance with EN 60721-3-4

Electromagnetic compatibility   • As per IEC/EN 61326 and NAMUR Recommendation 21 (NE 21)
(EMC)                           • Complies with emission limits for industry as per EN 55011
                                       Details are provided in the Declaration of Conformity.




                                Process
Medium temperature range        Sensor
                                0 to +80 °C (+32 to +176 °F)

Pressure-temperature ratings    The following material load diagrams refer to the entire device and not just the process connection.

                                Flange connection according to EN 1092-1 (DIN 2501)


                                                                    [psi]   [bar]
                                                                    300     20
                                                                    200
                                                                    100     10
                                                                      0       0
                                                                                    0   20 40 60 80 100 [°C]

                                                                                    40 80 120 160 200       [°F]
                                                                                                                                              A0015905


                                å 10     With lap joint flange, stamped plate PN 10, material 1.4301/304 (DN 50 to 200 / 2 to 8")


                                Flange connection according to EN 1092-1 (DIN 2501)


                                                                    [psi]   [bar]
                                                                    300     20
                                                                    200
                                                                    100     10
                                                                      0       0
                                                                                    0   20 40 60 80 100 [°C]

                                                                                    40 80 120 160 200       [°F]
                                                                                                                                              A0015906


                                å 11     With lap joint flange PN 10, material 1.4306/304L (DN 200 / 8")


                                Flange connection according to EN 1092-1 (DIN 2501)


                                                                    [psi]   [bar]
                                                                    300     20
                                                                    200
                                                                    100     10
                                                                      0       0
                                                                                    0   20 40 60 80 100 [°C]

                                                                                    40 80 120 160 200       [°F]
                                                                                                                                              A0015932


                                å 12     With lap joint flange PN 10/16, materials S235JR (DN 50 to 200 / 2 to 8") and 1.4306/304L (DN 50 to 150 /
                                         2 to 6"); With lap joint flange, stamped plate PN 10, material S235JR (DN 50 to 200 / 2 to 8")


24                                                                                                                                  Endress+Hauser
Proline Prosonic Flow B 200



                              Flange connection according to ASME B16.5


                                                                  [psi]   [bar]
                                                                 300      20
                                                                 200
                                                                 100      10
                                                                   0        0
                                                                                  0   20 40 60 80 100 [°C]

                                                                                  40 80 120 160 200       [°F]
                                                                                                                                          A0015568


                              å 13     With lap joint flange Class 150, materials 1.4404/316L and A105 (DN 50 to 200 / 2 to 8")


Flow limit                    Select the nominal diameter by optimizing between the required flow range and permissible pressure loss.
                                     For an overview of the measuring range full scale values, see the "Measuring range" section (® ä 6)

                              • The minimum recommended full scale value is approx. 1/20 of the maximum full scale value.
                              • In most applications, 10 to 50 % of the maximum full scale value can be considered ideal.

Pressure loss                 There is no pressure loss.

System pressure               Sensor
                              Max. 10 bar (145 psi)

Thermal insulation            For optimum temperature and methane fraction measurement (order characteristic for "Sensor version",
                              option 2 "Volume flow + Biogas analysis"), make sure that heat is neither lost nor applied to the sensor.
                              Thermal insulation can ensure that such heat transfer does not take place.
                              Thermal insulation is particularly recommended in situations where there is a large difference between the
                              process temperature and the ambient temperature. This can result in heat convection errors during
                              temperature measurement. A further factor which can lead to measurement errors due to heat convection is
                              a low flow velocity.




                              Mechanical construction
Design, dimensions            Compact version
                              Order code for "Housing", options C "GT20 two-chamber, aluminum coated" , S "GT18 two-chamber,
                              stainless steel"




Endress+Hauser                                                                                                                               25
Ultrasonic flowmeter-Biogas measurement
Ultrasonic flowmeter-Biogas measurement
Ultrasonic flowmeter-Biogas measurement
Ultrasonic flowmeter-Biogas measurement
Ultrasonic flowmeter-Biogas measurement
Ultrasonic flowmeter-Biogas measurement
Ultrasonic flowmeter-Biogas measurement
Ultrasonic flowmeter-Biogas measurement
Ultrasonic flowmeter-Biogas measurement
Ultrasonic flowmeter-Biogas measurement
Ultrasonic flowmeter-Biogas measurement
Ultrasonic flowmeter-Biogas measurement
Ultrasonic flowmeter-Biogas measurement
Ultrasonic flowmeter-Biogas measurement
Ultrasonic flowmeter-Biogas measurement
Ultrasonic flowmeter-Biogas measurement
Ultrasonic flowmeter-Biogas measurement
Ultrasonic flowmeter-Biogas measurement
Ultrasonic flowmeter-Biogas measurement

Contenu connexe

Tendances

Proline promass 80 f 83f-endress+hauser datasheet-coriolis mass flowmeter
Proline promass 80 f 83f-endress+hauser datasheet-coriolis mass flowmeterProline promass 80 f 83f-endress+hauser datasheet-coriolis mass flowmeter
Proline promass 80 f 83f-endress+hauser datasheet-coriolis mass flowmeterENVIMART
 
Proline promag 50 w endress+hauser datasheet-electromagnetic flowmeter
Proline promag 50 w endress+hauser datasheet-electromagnetic flowmeterProline promag 50 w endress+hauser datasheet-electromagnetic flowmeter
Proline promag 50 w endress+hauser datasheet-electromagnetic flowmeterENVIMART
 
Proline promag w 400 endress+hauser datasheet-electromagnetic flowmeter
Proline promag w 400 endress+hauser datasheet-electromagnetic flowmeterProline promag w 400 endress+hauser datasheet-electromagnetic flowmeter
Proline promag w 400 endress+hauser datasheet-electromagnetic flowmeterENVIMART
 
Micropilot fmr50 endress+hauser datasheet-free space radar
Micropilot fmr50 endress+hauser datasheet-free space radarMicropilot fmr50 endress+hauser datasheet-free space radar
Micropilot fmr50 endress+hauser datasheet-free space radarENVIMART
 
Liquiline cm42 endress+hauser datasheet
Liquiline cm42 endress+hauser datasheetLiquiline cm42 endress+hauser datasheet
Liquiline cm42 endress+hauser datasheetENVIMART
 
Deltabar s fmd76 77 78-endress+hauser datasheet-differential pressure measure...
Deltabar s fmd76 77 78-endress+hauser datasheet-differential pressure measure...Deltabar s fmd76 77 78-endress+hauser datasheet-differential pressure measure...
Deltabar s fmd76 77 78-endress+hauser datasheet-differential pressure measure...ENVIMART
 
Prosonic t fmu30 endress+hauser datasheet-ultrasonic level measurement
Prosonic t fmu30 endress+hauser datasheet-ultrasonic level measurementProsonic t fmu30 endress+hauser datasheet-ultrasonic level measurement
Prosonic t fmu30 endress+hauser datasheet-ultrasonic level measurementENVIMART
 
Prosonic s fdu90 endress+hauser datasheet-ultrasonic sensors
Prosonic s fdu90 endress+hauser datasheet-ultrasonic sensorsProsonic s fdu90 endress+hauser datasheet-ultrasonic sensors
Prosonic s fdu90 endress+hauser datasheet-ultrasonic sensorsENVIMART
 
Prosonic m fmu40 41 42_43_44-endress+hauser datasheet-ultrasonic level measur...
Prosonic m fmu40 41 42_43_44-endress+hauser datasheet-ultrasonic level measur...Prosonic m fmu40 41 42_43_44-endress+hauser datasheet-ultrasonic level measur...
Prosonic m fmu40 41 42_43_44-endress+hauser datasheet-ultrasonic level measur...ENVIMART
 
Computer control; an Overview. Astrom
Computer control; an Overview. AstromComputer control; an Overview. Astrom
Computer control; an Overview. AstromJOAQUIN REA
 
Ceraphant t ptc31 ptp31 ptp35-endress+hauser datasheet-pressure measurement
Ceraphant t ptc31 ptp31 ptp35-endress+hauser datasheet-pressure measurementCeraphant t ptc31 ptp31 ptp35-endress+hauser datasheet-pressure measurement
Ceraphant t ptc31 ptp31 ptp35-endress+hauser datasheet-pressure measurementENVIMART
 

Tendances (20)

Proline promass 80 f 83f-endress+hauser datasheet-coriolis mass flowmeter
Proline promass 80 f 83f-endress+hauser datasheet-coriolis mass flowmeterProline promass 80 f 83f-endress+hauser datasheet-coriolis mass flowmeter
Proline promass 80 f 83f-endress+hauser datasheet-coriolis mass flowmeter
 
Proline promag 50 w endress+hauser datasheet-electromagnetic flowmeter
Proline promag 50 w endress+hauser datasheet-electromagnetic flowmeterProline promag 50 w endress+hauser datasheet-electromagnetic flowmeter
Proline promag 50 w endress+hauser datasheet-electromagnetic flowmeter
 
Level radar measurement in liquids-Micropilot FMR50
Level radar measurement in liquids-Micropilot FMR50Level radar measurement in liquids-Micropilot FMR50
Level radar measurement in liquids-Micropilot FMR50
 
Ultrasonic flowmeter-Drinking water and process water
Ultrasonic flowmeter-Drinking water and process waterUltrasonic flowmeter-Drinking water and process water
Ultrasonic flowmeter-Drinking water and process water
 
Proline promag w 400 endress+hauser datasheet-electromagnetic flowmeter
Proline promag w 400 endress+hauser datasheet-electromagnetic flowmeterProline promag w 400 endress+hauser datasheet-electromagnetic flowmeter
Proline promag w 400 endress+hauser datasheet-electromagnetic flowmeter
 
Micropilot fmr50 endress+hauser datasheet-free space radar
Micropilot fmr50 endress+hauser datasheet-free space radarMicropilot fmr50 endress+hauser datasheet-free space radar
Micropilot fmr50 endress+hauser datasheet-free space radar
 
Liquiline cm42 endress+hauser datasheet
Liquiline cm42 endress+hauser datasheetLiquiline cm42 endress+hauser datasheet
Liquiline cm42 endress+hauser datasheet
 
Deltabar s fmd76 77 78-endress+hauser datasheet-differential pressure measure...
Deltabar s fmd76 77 78-endress+hauser datasheet-differential pressure measure...Deltabar s fmd76 77 78-endress+hauser datasheet-differential pressure measure...
Deltabar s fmd76 77 78-endress+hauser datasheet-differential pressure measure...
 
Capacitance level measurement-Liquicap M FMI51, FMI52
Capacitance level measurement-Liquicap M FMI51, FMI52Capacitance level measurement-Liquicap M FMI51, FMI52
Capacitance level measurement-Liquicap M FMI51, FMI52
 
Prosonic t fmu30 endress+hauser datasheet-ultrasonic level measurement
Prosonic t fmu30 endress+hauser datasheet-ultrasonic level measurementProsonic t fmu30 endress+hauser datasheet-ultrasonic level measurement
Prosonic t fmu30 endress+hauser datasheet-ultrasonic level measurement
 
Guided Level Radar-Levelflex M FMP40
Guided Level Radar-Levelflex M FMP40Guided Level Radar-Levelflex M FMP40
Guided Level Radar-Levelflex M FMP40
 
Prosonic s fdu90 endress+hauser datasheet-ultrasonic sensors
Prosonic s fdu90 endress+hauser datasheet-ultrasonic sensorsProsonic s fdu90 endress+hauser datasheet-ultrasonic sensors
Prosonic s fdu90 endress+hauser datasheet-ultrasonic sensors
 
Prosonic m fmu40 41 42_43_44-endress+hauser datasheet-ultrasonic level measur...
Prosonic m fmu40 41 42_43_44-endress+hauser datasheet-ultrasonic level measur...Prosonic m fmu40 41 42_43_44-endress+hauser datasheet-ultrasonic level measur...
Prosonic m fmu40 41 42_43_44-endress+hauser datasheet-ultrasonic level measur...
 
Computer control; an Overview. Astrom
Computer control; an Overview. AstromComputer control; an Overview. Astrom
Computer control; an Overview. Astrom
 
Flowmeter Promag 55S-Electromagnetic-Endress Hauser
Flowmeter Promag 55S-Electromagnetic-Endress HauserFlowmeter Promag 55S-Electromagnetic-Endress Hauser
Flowmeter Promag 55S-Electromagnetic-Endress Hauser
 
Proline Promag L 800-Electromagnetic Flowmeter
Proline Promag L 800-Electromagnetic FlowmeterProline Promag L 800-Electromagnetic Flowmeter
Proline Promag L 800-Electromagnetic Flowmeter
 
Electromagnetic flowmeter - Proline Promag H 200
Electromagnetic flowmeter - Proline Promag H 200Electromagnetic flowmeter - Proline Promag H 200
Electromagnetic flowmeter - Proline Promag H 200
 
Ultrasonic flowmeter-Drinking water, wastewater and process water.
Ultrasonic flowmeter-Drinking water, wastewater and process water.Ultrasonic flowmeter-Drinking water, wastewater and process water.
Ultrasonic flowmeter-Drinking water, wastewater and process water.
 
Electromagnetic flowmeter - Proline Promag 55H
Electromagnetic flowmeter - Proline Promag 55HElectromagnetic flowmeter - Proline Promag 55H
Electromagnetic flowmeter - Proline Promag 55H
 
Ceraphant t ptc31 ptp31 ptp35-endress+hauser datasheet-pressure measurement
Ceraphant t ptc31 ptp31 ptp35-endress+hauser datasheet-pressure measurementCeraphant t ptc31 ptp31 ptp35-endress+hauser datasheet-pressure measurement
Ceraphant t ptc31 ptp31 ptp35-endress+hauser datasheet-pressure measurement
 

Similaire à Ultrasonic flowmeter-Biogas measurement

Proline proline prowirl 72 f 72w_73f_73w-endress+hauser datasheet-vortex flow...
Proline proline prowirl 72 f 72w_73f_73w-endress+hauser datasheet-vortex flow...Proline proline prowirl 72 f 72w_73f_73w-endress+hauser datasheet-vortex flow...
Proline proline prowirl 72 f 72w_73f_73w-endress+hauser datasheet-vortex flow...ENVIMART
 
Proline promag d 400 endress+hauser datasheet-electromagnetic flowmeter
Proline promag d 400 endress+hauser datasheet-electromagnetic flowmeterProline promag d 400 endress+hauser datasheet-electromagnetic flowmeter
Proline promag d 400 endress+hauser datasheet-electromagnetic flowmeterENVIMART
 
Liquistation csf48 endress+hauser datasheet-automatic stationary sampler
Liquistation csf48 endress+hauser datasheet-automatic stationary samplerLiquistation csf48 endress+hauser datasheet-automatic stationary sampler
Liquistation csf48 endress+hauser datasheet-automatic stationary samplerENVIMART
 
Proline t mass b 150-endress+hauser datasheet-thermal mass flow measuring system
Proline t mass b 150-endress+hauser datasheet-thermal mass flow measuring systemProline t mass b 150-endress+hauser datasheet-thermal mass flow measuring system
Proline t mass b 150-endress+hauser datasheet-thermal mass flow measuring systemENVIMART
 
Prosonic flow 91 wa1 clamp on endress+hauser datasheet-ultrasonic flowmeter
Prosonic flow 91 wa1 clamp on endress+hauser datasheet-ultrasonic flowmeterProsonic flow 91 wa1 clamp on endress+hauser datasheet-ultrasonic flowmeter
Prosonic flow 91 wa1 clamp on endress+hauser datasheet-ultrasonic flowmeterENVIMART
 
Liquiphant m density densitycontroller fml621 endress+hauser datasheet
Liquiphant m density densitycontroller fml621 endress+hauser datasheetLiquiphant m density densitycontroller fml621 endress+hauser datasheet
Liquiphant m density densitycontroller fml621 endress+hauser datasheetENVIMART
 
Proline promag 55 s endress+hauser datasheet-electromagnetic flowmeter
Proline promag 55 s endress+hauser datasheet-electromagnetic flowmeterProline promag 55 s endress+hauser datasheet-electromagnetic flowmeter
Proline promag 55 s endress+hauser datasheet-electromagnetic flowmeterENVIMART
 

Similaire à Ultrasonic flowmeter-Biogas measurement (19)

Vortex flowmeter for gas, steam and liquids
Vortex flowmeter for gas, steam and liquidsVortex flowmeter for gas, steam and liquids
Vortex flowmeter for gas, steam and liquids
 
Proline proline prowirl 72 f 72w_73f_73w-endress+hauser datasheet-vortex flow...
Proline proline prowirl 72 f 72w_73f_73w-endress+hauser datasheet-vortex flow...Proline proline prowirl 72 f 72w_73f_73w-endress+hauser datasheet-vortex flow...
Proline proline prowirl 72 f 72w_73f_73w-endress+hauser datasheet-vortex flow...
 
Proline promag d 400 endress+hauser datasheet-electromagnetic flowmeter
Proline promag d 400 endress+hauser datasheet-electromagnetic flowmeterProline promag d 400 endress+hauser datasheet-electromagnetic flowmeter
Proline promag d 400 endress+hauser datasheet-electromagnetic flowmeter
 
Liquistation csf48 endress+hauser datasheet-automatic stationary sampler
Liquistation csf48 endress+hauser datasheet-automatic stationary samplerLiquistation csf48 endress+hauser datasheet-automatic stationary sampler
Liquistation csf48 endress+hauser datasheet-automatic stationary sampler
 
Proline Promag P200-Electromagnetic Flowmeter
Proline Promag P200-Electromagnetic FlowmeterProline Promag P200-Electromagnetic Flowmeter
Proline Promag P200-Electromagnetic Flowmeter
 
Water samplers-Liquistation CSF48
Water samplers-Liquistation CSF48Water samplers-Liquistation CSF48
Water samplers-Liquistation CSF48
 
Electromagnetic flowmeter - Proline Promag 50H, 53H
Electromagnetic flowmeter - Proline Promag 50H, 53HElectromagnetic flowmeter - Proline Promag 50H, 53H
Electromagnetic flowmeter - Proline Promag 50H, 53H
 
Proline t mass b 150-endress+hauser datasheet-thermal mass flow measuring system
Proline t mass b 150-endress+hauser datasheet-thermal mass flow measuring systemProline t mass b 150-endress+hauser datasheet-thermal mass flow measuring system
Proline t mass b 150-endress+hauser datasheet-thermal mass flow measuring system
 
Prosonic flow 91 wa1 clamp on endress+hauser datasheet-ultrasonic flowmeter
Prosonic flow 91 wa1 clamp on endress+hauser datasheet-ultrasonic flowmeterProsonic flow 91 wa1 clamp on endress+hauser datasheet-ultrasonic flowmeter
Prosonic flow 91 wa1 clamp on endress+hauser datasheet-ultrasonic flowmeter
 
Liquiphant M Density and Density Computer FML621
Liquiphant M Density and Density Computer FML621Liquiphant M Density and Density Computer FML621
Liquiphant M Density and Density Computer FML621
 
Ultrasonic flowmeter-Chemical or process applications
Ultrasonic flowmeter-Chemical or process applicationsUltrasonic flowmeter-Chemical or process applications
Ultrasonic flowmeter-Chemical or process applications
 
Electromagnetic flowmeter - Proline Promag 50D
Electromagnetic flowmeter - Proline Promag 50DElectromagnetic flowmeter - Proline Promag 50D
Electromagnetic flowmeter - Proline Promag 50D
 
Electromagnetic flowmeter - Proline Promag 10H
Electromagnetic flowmeter - Proline Promag 10HElectromagnetic flowmeter - Proline Promag 10H
Electromagnetic flowmeter - Proline Promag 10H
 
Ga dat cam bien
Ga dat cam bien Ga dat cam bien
Ga dat cam bien
 
Liquiphant m density densitycontroller fml621 endress+hauser datasheet
Liquiphant m density densitycontroller fml621 endress+hauser datasheetLiquiphant m density densitycontroller fml621 endress+hauser datasheet
Liquiphant m density densitycontroller fml621 endress+hauser datasheet
 
pH.ORP Transmitter-Analog sensors-Digital sensors
pH.ORP Transmitter-Analog sensors-Digital sensorspH.ORP Transmitter-Analog sensors-Digital sensors
pH.ORP Transmitter-Analog sensors-Digital sensors
 
Proline Promag 50L-Electromagnetic Flowmeter
Proline Promag 50L-Electromagnetic FlowmeterProline Promag 50L-Electromagnetic Flowmeter
Proline Promag 50L-Electromagnetic Flowmeter
 
Flowmeter Promag W 800-Electromagnetic-Battery Powered
Flowmeter Promag W 800-Electromagnetic-Battery PoweredFlowmeter Promag W 800-Electromagnetic-Battery Powered
Flowmeter Promag W 800-Electromagnetic-Battery Powered
 
Proline promag 55 s endress+hauser datasheet-electromagnetic flowmeter
Proline promag 55 s endress+hauser datasheet-electromagnetic flowmeterProline promag 55 s endress+hauser datasheet-electromagnetic flowmeter
Proline promag 55 s endress+hauser datasheet-electromagnetic flowmeter
 

Plus de Edress Hauser: Flow Meter, Level, Pressure, Temperature

Plus de Edress Hauser: Flow Meter, Level, Pressure, Temperature (20)

Microwave barrier- Soliwave FQR56/FDR56
Microwave barrier- Soliwave FQR56/FDR56Microwave barrier- Soliwave FQR56/FDR56
Microwave barrier- Soliwave FQR56/FDR56
 
Microwave barrier-Soliwave M FQR50 / FDR50
Microwave barrier-Soliwave M FQR50 / FDR50Microwave barrier-Soliwave M FQR50 / FDR50
Microwave barrier-Soliwave M FQR50 / FDR50
 
Level Limit Switch-Soliswitch FTE31
Level Limit Switch-Soliswitch FTE31Level Limit Switch-Soliswitch FTE31
Level Limit Switch-Soliswitch FTE31
 
Level limit switch-Soliswitch FTE30
Level limit switch-Soliswitch FTE30Level limit switch-Soliswitch FTE30
Level limit switch-Soliswitch FTE30
 
Flow indicator for bulk solids-Solimotion FTR20
Flow indicator for bulk solids-Solimotion FTR20Flow indicator for bulk solids-Solimotion FTR20
Flow indicator for bulk solids-Solimotion FTR20
 
Level measurement with Prothermo NMT532
Level measurement with Prothermo NMT532 Level measurement with Prothermo NMT532
Level measurement with Prothermo NMT532
 
Conductive Limit Detection-Rod Probe 11263
Conductive Limit Detection-Rod Probe 11263Conductive Limit Detection-Rod Probe 11263
Conductive Limit Detection-Rod Probe 11263
 
FTW360 compact pump protector
FTW360 compact pump protectorFTW360 compact pump protector
FTW360 compact pump protector
 
Conductive-Point level switch for multiple point
Conductive-Point level switch for multiple pointConductive-Point level switch for multiple point
Conductive-Point level switch for multiple point
 
Level limit switch compact design-Liquiphant T FTL20H
Level limit switch compact design-Liquiphant T FTL20HLevel limit switch compact design-Liquiphant T FTL20H
Level limit switch compact design-Liquiphant T FTL20H
 
Vibronic-Point level switch for all kinds of liquids
Vibronic-Point level switch for all kinds of liquidsVibronic-Point level switch for all kinds of liquids
Vibronic-Point level switch for all kinds of liquids
 
Vibronic-Point level switch-Liquiphant M FTL51C
Vibronic-Point level switch-Liquiphant M FTL51CVibronic-Point level switch-Liquiphant M FTL51C
Vibronic-Point level switch-Liquiphant M FTL51C
 
Level limit switch for liquids-Liquiphant T FTL20
Level limit switch for liquids-Liquiphant T FTL20Level limit switch for liquids-Liquiphant T FTL20
Level limit switch for liquids-Liquiphant T FTL20
 
Radiometric measuring technology-Gammapilot FTG20
Radiometric measuring technology-Gammapilot FTG20Radiometric measuring technology-Gammapilot FTG20
Radiometric measuring technology-Gammapilot FTG20
 
Differential pressure measurement-Level transmiter
Differential pressure measurement-Level transmiterDifferential pressure measurement-Level transmiter
Differential pressure measurement-Level transmiter
 
Hydrostatic Level Measurement-Deltapilot S DB50/50L/51/52/53
Hydrostatic Level Measurement-Deltapilot S DB50/50L/51/52/53Hydrostatic Level Measurement-Deltapilot S DB50/50L/51/52/53
Hydrostatic Level Measurement-Deltapilot S DB50/50L/51/52/53
 
Hydrostatic level measurement-Deltapilot M FMB50/51/52/53
Hydrostatic level measurement-Deltapilot M FMB50/51/52/53Hydrostatic level measurement-Deltapilot M FMB50/51/52/53
Hydrostatic level measurement-Deltapilot M FMB50/51/52/53
 
Ultrasonic Level Measurement-Prosonic M FMU40/41/42/43/44
Ultrasonic Level Measurement-Prosonic M FMU40/41/42/43/44Ultrasonic Level Measurement-Prosonic M FMU40/41/42/43/44
Ultrasonic Level Measurement-Prosonic M FMU40/41/42/43/44
 
Ultrasonic Level Measurement-Prosonic T FMU30
Ultrasonic Level Measurement-Prosonic T FMU30Ultrasonic Level Measurement-Prosonic T FMU30
Ultrasonic Level Measurement-Prosonic T FMU30
 
Electromechanical Level Measuring System-Silopilot M FMM50
Electromechanical Level Measuring System-Silopilot M FMM50Electromechanical Level Measuring System-Silopilot M FMM50
Electromechanical Level Measuring System-Silopilot M FMM50
 

Dernier

Varsha Sewlal- Cyber Attacks on Critical Critical Infrastructure
Varsha Sewlal- Cyber Attacks on Critical Critical InfrastructureVarsha Sewlal- Cyber Attacks on Critical Critical Infrastructure
Varsha Sewlal- Cyber Attacks on Critical Critical Infrastructureitnewsafrica
 
TrustArc Webinar - How to Build Consumer Trust Through Data Privacy
TrustArc Webinar - How to Build Consumer Trust Through Data PrivacyTrustArc Webinar - How to Build Consumer Trust Through Data Privacy
TrustArc Webinar - How to Build Consumer Trust Through Data PrivacyTrustArc
 
Transcript: New from BookNet Canada for 2024: Loan Stars - Tech Forum 2024
Transcript: New from BookNet Canada for 2024: Loan Stars - Tech Forum 2024Transcript: New from BookNet Canada for 2024: Loan Stars - Tech Forum 2024
Transcript: New from BookNet Canada for 2024: Loan Stars - Tech Forum 2024BookNet Canada
 
New from BookNet Canada for 2024: Loan Stars - Tech Forum 2024
New from BookNet Canada for 2024: Loan Stars - Tech Forum 2024New from BookNet Canada for 2024: Loan Stars - Tech Forum 2024
New from BookNet Canada for 2024: Loan Stars - Tech Forum 2024BookNet Canada
 
The State of Passkeys with FIDO Alliance.pptx
The State of Passkeys with FIDO Alliance.pptxThe State of Passkeys with FIDO Alliance.pptx
The State of Passkeys with FIDO Alliance.pptxLoriGlavin3
 
How to write a Business Continuity Plan
How to write a Business Continuity PlanHow to write a Business Continuity Plan
How to write a Business Continuity PlanDatabarracks
 
Generative AI - Gitex v1Generative AI - Gitex v1.pptx
Generative AI - Gitex v1Generative AI - Gitex v1.pptxGenerative AI - Gitex v1Generative AI - Gitex v1.pptx
Generative AI - Gitex v1Generative AI - Gitex v1.pptxfnnc6jmgwh
 
So einfach geht modernes Roaming fuer Notes und Nomad.pdf
So einfach geht modernes Roaming fuer Notes und Nomad.pdfSo einfach geht modernes Roaming fuer Notes und Nomad.pdf
So einfach geht modernes Roaming fuer Notes und Nomad.pdfpanagenda
 
Connecting the Dots for Information Discovery.pdf
Connecting the Dots for Information Discovery.pdfConnecting the Dots for Information Discovery.pdf
Connecting the Dots for Information Discovery.pdfNeo4j
 
MuleSoft Online Meetup Group - B2B Crash Course: Release SparkNotes
MuleSoft Online Meetup Group - B2B Crash Course: Release SparkNotesMuleSoft Online Meetup Group - B2B Crash Course: Release SparkNotes
MuleSoft Online Meetup Group - B2B Crash Course: Release SparkNotesManik S Magar
 
A Framework for Development in the AI Age
A Framework for Development in the AI AgeA Framework for Development in the AI Age
A Framework for Development in the AI AgeCprime
 
Scale your database traffic with Read & Write split using MySQL Router
Scale your database traffic with Read & Write split using MySQL RouterScale your database traffic with Read & Write split using MySQL Router
Scale your database traffic with Read & Write split using MySQL RouterMydbops
 
How to Effectively Monitor SD-WAN and SASE Environments with ThousandEyes
How to Effectively Monitor SD-WAN and SASE Environments with ThousandEyesHow to Effectively Monitor SD-WAN and SASE Environments with ThousandEyes
How to Effectively Monitor SD-WAN and SASE Environments with ThousandEyesThousandEyes
 
Merck Moving Beyond Passwords: FIDO Paris Seminar.pptx
Merck Moving Beyond Passwords: FIDO Paris Seminar.pptxMerck Moving Beyond Passwords: FIDO Paris Seminar.pptx
Merck Moving Beyond Passwords: FIDO Paris Seminar.pptxLoriGlavin3
 
Genislab builds better products and faster go-to-market with Lean project man...
Genislab builds better products and faster go-to-market with Lean project man...Genislab builds better products and faster go-to-market with Lean project man...
Genislab builds better products and faster go-to-market with Lean project man...Farhan Tariq
 
Top 10 Hubspot Development Companies in 2024
Top 10 Hubspot Development Companies in 2024Top 10 Hubspot Development Companies in 2024
Top 10 Hubspot Development Companies in 2024TopCSSGallery
 
Passkey Providers and Enabling Portability: FIDO Paris Seminar.pptx
Passkey Providers and Enabling Portability: FIDO Paris Seminar.pptxPasskey Providers and Enabling Portability: FIDO Paris Seminar.pptx
Passkey Providers and Enabling Portability: FIDO Paris Seminar.pptxLoriGlavin3
 
Glenn Lazarus- Why Your Observability Strategy Needs Security Observability
Glenn Lazarus- Why Your Observability Strategy Needs Security ObservabilityGlenn Lazarus- Why Your Observability Strategy Needs Security Observability
Glenn Lazarus- Why Your Observability Strategy Needs Security Observabilityitnewsafrica
 
The Fit for Passkeys for Employee and Consumer Sign-ins: FIDO Paris Seminar.pptx
The Fit for Passkeys for Employee and Consumer Sign-ins: FIDO Paris Seminar.pptxThe Fit for Passkeys for Employee and Consumer Sign-ins: FIDO Paris Seminar.pptx
The Fit for Passkeys for Employee and Consumer Sign-ins: FIDO Paris Seminar.pptxLoriGlavin3
 
A Deep Dive on Passkeys: FIDO Paris Seminar.pptx
A Deep Dive on Passkeys: FIDO Paris Seminar.pptxA Deep Dive on Passkeys: FIDO Paris Seminar.pptx
A Deep Dive on Passkeys: FIDO Paris Seminar.pptxLoriGlavin3
 

Dernier (20)

Varsha Sewlal- Cyber Attacks on Critical Critical Infrastructure
Varsha Sewlal- Cyber Attacks on Critical Critical InfrastructureVarsha Sewlal- Cyber Attacks on Critical Critical Infrastructure
Varsha Sewlal- Cyber Attacks on Critical Critical Infrastructure
 
TrustArc Webinar - How to Build Consumer Trust Through Data Privacy
TrustArc Webinar - How to Build Consumer Trust Through Data PrivacyTrustArc Webinar - How to Build Consumer Trust Through Data Privacy
TrustArc Webinar - How to Build Consumer Trust Through Data Privacy
 
Transcript: New from BookNet Canada for 2024: Loan Stars - Tech Forum 2024
Transcript: New from BookNet Canada for 2024: Loan Stars - Tech Forum 2024Transcript: New from BookNet Canada for 2024: Loan Stars - Tech Forum 2024
Transcript: New from BookNet Canada for 2024: Loan Stars - Tech Forum 2024
 
New from BookNet Canada for 2024: Loan Stars - Tech Forum 2024
New from BookNet Canada for 2024: Loan Stars - Tech Forum 2024New from BookNet Canada for 2024: Loan Stars - Tech Forum 2024
New from BookNet Canada for 2024: Loan Stars - Tech Forum 2024
 
The State of Passkeys with FIDO Alliance.pptx
The State of Passkeys with FIDO Alliance.pptxThe State of Passkeys with FIDO Alliance.pptx
The State of Passkeys with FIDO Alliance.pptx
 
How to write a Business Continuity Plan
How to write a Business Continuity PlanHow to write a Business Continuity Plan
How to write a Business Continuity Plan
 
Generative AI - Gitex v1Generative AI - Gitex v1.pptx
Generative AI - Gitex v1Generative AI - Gitex v1.pptxGenerative AI - Gitex v1Generative AI - Gitex v1.pptx
Generative AI - Gitex v1Generative AI - Gitex v1.pptx
 
So einfach geht modernes Roaming fuer Notes und Nomad.pdf
So einfach geht modernes Roaming fuer Notes und Nomad.pdfSo einfach geht modernes Roaming fuer Notes und Nomad.pdf
So einfach geht modernes Roaming fuer Notes und Nomad.pdf
 
Connecting the Dots for Information Discovery.pdf
Connecting the Dots for Information Discovery.pdfConnecting the Dots for Information Discovery.pdf
Connecting the Dots for Information Discovery.pdf
 
MuleSoft Online Meetup Group - B2B Crash Course: Release SparkNotes
MuleSoft Online Meetup Group - B2B Crash Course: Release SparkNotesMuleSoft Online Meetup Group - B2B Crash Course: Release SparkNotes
MuleSoft Online Meetup Group - B2B Crash Course: Release SparkNotes
 
A Framework for Development in the AI Age
A Framework for Development in the AI AgeA Framework for Development in the AI Age
A Framework for Development in the AI Age
 
Scale your database traffic with Read & Write split using MySQL Router
Scale your database traffic with Read & Write split using MySQL RouterScale your database traffic with Read & Write split using MySQL Router
Scale your database traffic with Read & Write split using MySQL Router
 
How to Effectively Monitor SD-WAN and SASE Environments with ThousandEyes
How to Effectively Monitor SD-WAN and SASE Environments with ThousandEyesHow to Effectively Monitor SD-WAN and SASE Environments with ThousandEyes
How to Effectively Monitor SD-WAN and SASE Environments with ThousandEyes
 
Merck Moving Beyond Passwords: FIDO Paris Seminar.pptx
Merck Moving Beyond Passwords: FIDO Paris Seminar.pptxMerck Moving Beyond Passwords: FIDO Paris Seminar.pptx
Merck Moving Beyond Passwords: FIDO Paris Seminar.pptx
 
Genislab builds better products and faster go-to-market with Lean project man...
Genislab builds better products and faster go-to-market with Lean project man...Genislab builds better products and faster go-to-market with Lean project man...
Genislab builds better products and faster go-to-market with Lean project man...
 
Top 10 Hubspot Development Companies in 2024
Top 10 Hubspot Development Companies in 2024Top 10 Hubspot Development Companies in 2024
Top 10 Hubspot Development Companies in 2024
 
Passkey Providers and Enabling Portability: FIDO Paris Seminar.pptx
Passkey Providers and Enabling Portability: FIDO Paris Seminar.pptxPasskey Providers and Enabling Portability: FIDO Paris Seminar.pptx
Passkey Providers and Enabling Portability: FIDO Paris Seminar.pptx
 
Glenn Lazarus- Why Your Observability Strategy Needs Security Observability
Glenn Lazarus- Why Your Observability Strategy Needs Security ObservabilityGlenn Lazarus- Why Your Observability Strategy Needs Security Observability
Glenn Lazarus- Why Your Observability Strategy Needs Security Observability
 
The Fit for Passkeys for Employee and Consumer Sign-ins: FIDO Paris Seminar.pptx
The Fit for Passkeys for Employee and Consumer Sign-ins: FIDO Paris Seminar.pptxThe Fit for Passkeys for Employee and Consumer Sign-ins: FIDO Paris Seminar.pptx
The Fit for Passkeys for Employee and Consumer Sign-ins: FIDO Paris Seminar.pptx
 
A Deep Dive on Passkeys: FIDO Paris Seminar.pptx
A Deep Dive on Passkeys: FIDO Paris Seminar.pptxA Deep Dive on Passkeys: FIDO Paris Seminar.pptx
A Deep Dive on Passkeys: FIDO Paris Seminar.pptx
 

Ultrasonic flowmeter-Biogas measurement

  • 1. Technical Information Proline Prosonic Flow B 200 Ultrasonic flow measuring system The device for accurate, reliable biogas measurement under variable process conditions Application Your benefits • Reliable measurement of wet biogas, digester gas and Biogas measurement for a wide range of applications landfill gas under low process pressure, low flow with optional real-time measurement of the biogas rates and varying gas compositions. methane fraction combined with genuine loop-powered • The Ultrasonic measuring principle is unaffected by technology. the gas composition. Sizing - correct product selection Device properties: Applicator - the reliable, easy-to-use tool for selecting • Medium temperature: 0 to 80 °C (32 to 176 °F) and sizing measuring devices for every application • Process pressure: max. 10 bar (145 psi) Installation - simple and efficient • Nominal diameter: DN 50 to 200 (2 to 8") • Short inlet and outlet runs • Accuracy: • Reduced wiring thanks to loop-powered technology – Volume flow: ±1.5 % o.r. – Methane: ±2 % abs. (optional) Commissioning - reliable and intuitive • Loop powered transmitter made of aluminum or Guided parameterization ("Make-it-run" Wizards) stainless steel Operation - increased measurement availability • Graphical local display with operation from the • Multivariable measurement: volume flow and, outside (Touch Control) optionally, methane fraction and temperature • Communication via 4-20 mA HART • No pressure loss • Ex approvals accepted worldwide: ATEX, IECEx, • Diagnostic capability CCSAUS, NEPSI (intrinsically safe or explosion proof • Automatic data restore by HistoROM design) Cost-effective Life Cycle Management by W@M TI01018D/06/EN/02.12 71196568
  • 2. Table of contents Proline Prosonic Flow B 200 Table of contents Document information . . . . . . . . . . . . . . . . . . . . . . . . 3 Process . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Symbols used . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Medium temperature range . . . . . . . . . . . . . . . . . . . . . . . 24 Pressure-temperature ratings . . . . . . . . . . . . . . . . . . . . . . 24 Function and system design . . . . . . . . . . . . . . . . . . . . 4 Flow limit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Pressure loss . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Measuring principle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 System pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Measuring system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Thermal insulation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Measured variable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Mechanical construction . . . . . . . . . . . . . . . . . . . . . 25 Design, dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Measuring range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 Operable flow range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Materials . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 Input signal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Process connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Output signal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Operability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 Operating concept . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 Signal on alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Local operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 Load . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Remote operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 Ex connection data . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Low flow cut off . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Galvanic isolation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Certificates and approvals . . . . . . . . . . . . . . . . . . . . 37 Protocol-specific data . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 CE mark . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 C-Tick symbol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 Power supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Ex approval . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 Pressure Equipment Directive . . . . . . . . . . . . . . . . . . . . . . 38 Terminal assignment . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Other standards and guidelines . . . . . . . . . . . . . . . . . . . . . 38 Supply voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Power consumption . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Current consumption . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Ordering information . . . . . . . . . . . . . . . . . . . . . . . . 39 Power supply failure . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Electrical connection . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Application packages . . . . . . . . . . . . . . . . . . . . . . . . 39 Potential equalization . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Diagnostics functions . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 Terminals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Cable entries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Cable specification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 Overvoltage protection . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Device-specific accessories . . . . . . . . . . . . . . . . . . . . . . . . 39 Communication-specific accessories . . . . . . . . . . . . . . . . . . 40 Service-specific accessories . . . . . . . . . . . . . . . . . . . . . . . . 41 Performance characteristics . . . . . . . . . . . . . . . . . . . 17 System components . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 Reference conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Maximum measured error . . . . . . . . . . . . . . . . . . . . . . . . 18 Repeatability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 Response time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Standard documentation . . . . . . . . . . . . . . . . . . . . . . . . . 42 Influence of ambient temperature . . . . . . . . . . . . . . . . . . . 18 Supplementary device-dependent documentation . . . . . . . . . . 42 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Registered trademarks . . . . . . . . . . . . . . . . . . . . . . . 42 Mounting location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Orientation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Inlet and outlet runs . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Special mounting instructions . . . . . . . . . . . . . . . . . . . . . . 21 Environment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Ambient temperature range . . . . . . . . . . . . . . . . . . . . . . . 22 Storage temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Degree of protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Shock resistance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Vibration resistance . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Electromagnetic compatibility (EMC) . . . . . . . . . . . . . . . . . 24 2 Endress+Hauser
  • 3. Proline Prosonic Flow B 200 Document information Symbols used Electrical symbols Symbol Meaning Direct current A0011197 A terminal to which DC voltage is applied or through which direct current flows. Alternating current A0011198 A terminal to which alternating voltage is applied or through which alternating current flows. Direct current and alternating current A0017381 • A terminal to which alternating voltage or DC voltage is applied. • A terminal through which alternating current or direct current flows. Ground connection A grounded terminal which, as far as the operator is concerned, is grounded via a grounding system. A0011200 Protective ground connection A terminal which must be connected to ground prior to establishing any other connections. A0011199 Equipotential connection A connection that has to be connected to the plant grounding system: This may be a potential A0011201 equalization line or a star grounding system depending on national or company codes of practice. Symbols for certain types of information Symbol Meaning Allowed Indicates procedures, processes or actions that are allowed. A0011182 Preferred Indicates procedures, processes or actions that are preferred. A0011183 Forbidden Indicates procedures, processes or actions that are forbidden. A0011184 Tip Indicates additional information. A0011193 Reference to documentation Refers to the corresponding device documentation. A0011194 Reference to page Refers to the corresponding page number. A0011195 Reference to graphic Refers to the corresponding graphic number and page number. A0011196 Symbols in graphics Symbol Meaning 1, 2, 3,... Item numbers , , … Series of steps A, B, C, ... Views A-A, B-B, C-C, ... Sections Flow direction A0013441 Endress+Hauser 3
  • 4. Proline Prosonic Flow B 200 Symbol Meaning Hazardous area - Indicates a hazardous area. A0011187 Safe area (non-hazardous area) . Indicates a non-hazardous area. A0011188 Function and system design Measuring principle A Prosonic Flow inline flowmeter measures the flow rate of the passing fluid by using sensor pairs located on opposite sides of the meter body and at an angle so that one of the sensors in the pair is slightly downstream. The design is non-invasive and does not have any moving parts. The flow signal is established by alternating an acoustic signal between the sensor pairs and measuring the time of flight of each transmission. Then utilizing the fact that sound travels faster with the flow versus against the flow, this differential time (D T) can be used to determine the fluids velocity between the sensors. The volume flow rate is established by combining all the flow velocities determined by the sensor pairs with the cross sectional area of the meter body and extensive knowledge about fluid flow dynamics. The design of the sensors and their position ensures that only a short straight run of pipe upstream of the meter is required after typical flow obstructions such as bends in one or two planes. Advance digital signal processing facilitates constant validation of the flow measurement reducing susceptibility to multiphase flow conditions and increases the reliability of the measurement. T1 T1' DT » e A0015451 Direct measurement of the methane fraction (CH4) The sound velocity, temperature and chemical composition of a gas are directly related to one another. If two of these characteristic quantities are known, the third can be calculated. The higher the gas temperature or the methane fraction, the higher the sound velocity in biogas, for example. Since the measuring device accurately measures both the sound velocity and the current gas temperature, the methane fraction can be calculated directly and displayed on site without the need for an additional measuring instrument . The relative humidity of biogas is usually 100 %. Thus, the water content can be determined by the temperature measurement and can be compensated for. The measuring device is unique in its ability to measure the methane fraction directly, making it possible to monitor the gas flow and gas quality 24/7. In this way, operators of a biogas plant, for example, can react swiftly and specifically to problems in the digestion process. 4 Endress+Hauser
  • 5. Proline Prosonic Flow B 200 [ft/s] [m/s] 1600 500 1450 450 T 1300 400 1150 350 1000 300 850 250 700 200 0 10 20 30 40 50 60 70 80 90 100 [%] A0016160 å1 Calculation of the methane fraction [%] based on the sound velocity [m/s (ft/s)] and a temperature T of 40 °C (104 °F), for example Measuring system The device consists of a transmitter and a sensor. One device version is available: compact version, transmitter and sensor form a mechanical unit. Transmitter Prosonic Flow 200 Materials: • Stainless steel 1.4404/316L • Aluminum coated AlSi10Mg Configuration: • External operation via four-line, illuminated local display with touch control and guided menus ("Make-it-run" wizards) for applications A0013471 • Via operating tools (e.g. FieldCare) Sensor Prosonic Flow B • Designed exclusively to measure: – Biogas Single-path version: DN 50 (2"), – Coal seam gas DN 80 (3") – Air – Methane – Nitrogen – Gas with a very high methane fraction • Range of nominal diameter: DN 50 to 200 (2 to 8") • Materials: – Sensor: Stainless steel 1.4404/316L, cold worked Stainless steel 1.4435/316L, cold worked A0015826 – Process connections: Two-path version: DN 100 to 200 (4 Stainless steel 1.4301/304, to 8") Stainless steel 1.4306/304L, Stainless steel 1.4404/316L, Steel S235JR, Carbon steel A105 A0015452 Endress+Hauser 5
  • 6. Proline Prosonic Flow B 200 Input Measured variable Direct measured variables Volume flow Calculated measured variables • Corrected volume flow • Mass flow Optional measured variables (can be ordered) Order code for "Sensor version", option 2 "Volume flow + Biogas analysis" • Corrected methane volume flow • Energy flow • Methane fraction • Gross calorific value • Wobbe index • Temperature Measuring range Standard (Order code for "Calibration Flow", option 1 "Operable flow range 30 : 1") Nominal diameter Velocity Effective volume flow [mm] [in] [m/s] [ft/s] [m3/h] [ft3/h] 50 2 1 to 30 3.28 to 98.4 9 to 269 316 to 9 495 80 3 1 to 30 3.28 to 98.4 20 to 611 720 to 21 592 100 4 1 to 30 3.28 to 98.4 34 to 1 032 1 215 to 36 443 150 6 1 to 30 3.28 to 98.4 76 to 2 290 2 695 to 80 862 200 8 1 to 30 3.28 to 98.4 131 to 3 925 4 620 to 138 596 Optional (Order code for "Calibration Flow", option 2 "Operable flow range 100 : 1") Nominal diameter Velocity Effective volume flow [mm] [in] [m/s] [ft/s] [m3/h] [ft3/h] 50 2 0.3 to 30 0.98 to 98.4 3 to 269 95 to 9 495 80 3 0.3 to 30 0.98 to 98.4 6 to 611 215 to 21 592 100 4 0.3 to 30 0.98 to 98.4 11 to 1 032 363 to 36 443 150 6 0.3 to 30 0.98 to 98.4 25 to 2 290 805 to 80 862 200 8 0.3 to 30 0.98 to 98.4 43 to 3 925 1 365 to 138 596 The values in the table should only be regarded as reference values. To calculate the measuring range, use the Applicator sizing tool (® ä 41) Recommended measuring range "Flow limit" section (® ä 25) Operable flow range • 30 : 1 (standard; order code for "Calibration Flow", option 1 "Operable flow range 30 : 1") • 100 : 1 (optional; order code for "Calibration Flow", option 2 "Operable flow range 100 : 1") Flow rates above the preset full scale value do not overload the amplifier so the totalized values are registered correctly. 6 Endress+Hauser
  • 7. Proline Prosonic Flow B 200 Input signal HART protocol To increase the accuracy of certain measured variables, a measured pressure value can be used instead of a fixed process pressure. For this purpose, the measuring device continuously reads in the process pressure from a pressure transmitter (e.g. Cerabar M or Cerabar S) via the HART protocol. The pressure transmitter must support the following protocol-specific functions: • HART protocol • Burst mode • Endress+Hauser recommends the use of an absolute pressure transmitter • Various pressure transmitters can be ordered from Endress+Hauser: see "Accessories" section (® ä 41) • Please comply with the special mounting instructions when using pressure transmitters (® ä 21) External pressure compensation is recommended to calculate the following measured variables: • Corrected volume flow • Corrected methane volume flow • Mass flow • Energy flow Output Output signal Current output Current output 1 4-20 mA HART (passive) Current output 2 4-20 mA (passive) Resolution < 1 µA Damping Adjustable: 0.07 to 999 s Assignable measured • Volume flow variables • Corrected volume flow • Corrected methane volume flow • Mass flow • Energy flow • Methane fraction • Gross calorific value • Wobbe index • Temperature Pulse/frequency/switch output Function Can be set to pulse, frequency or switch output Version Passive, open collector Maximum input values • DC 35 V • 50 mA For information on the Ex connection values (® ä 10) Voltage drop • For £ 2 mA: 2 V • For 10 mA: 8 V Residual current £ 0.05 mA Pulse output Pulse width Adjustable: 5 to 2 000 ms Maximum pulse rate 100 Impulse/s Pulse value Adjustable Endress+Hauser 7
  • 8. Proline Prosonic Flow B 200 Assignable measured • Volume flow variables • Corrected volume flow • Corrected methane volume flow • Mass flow • Energy flow Frequency output Output frequency Adjustable: 0 to 1 000 Hz Damping Adjustable: 0 to 999 s Pulse/pause ratio 1:1 Assignable measured • Volume flow variables • Corrected volume flow • Corrected methane volume flow • Mass flow • Energy flow • Methane fraction • Gross calorific value • Wobbe index • Temperature Switch output Switching behavior Binary, conductive or non-conductive Switching delay Adjustable: 0 to 100 s Number of switching Unlimited cycles Assignable functions • Off • On • Diagnostic behavior • Limit value – Volume flow – Corrected volume flow – Corrected methane volume flow – Mass flow – Energy flow – Methane fraction – Gross calorific value – Wobbe index – Temperature – Totalizer 1 to 3 • Flow direction monitoring • Status Low flow cut off Signal on alarm Depending on the interface, failure information is displayed as follows: Current output 4-20 mA Failure mode Selectable (as per NAMUR recommendation NE 43): • Minimum value: 3.6 mA • Maximum value: 22 mA • Defined value: 3.59 to 22.5 mA • Actual value • Last valid value HART Device diagnostics Device condition can be read out via HART Command 48 8 Endress+Hauser
  • 9. Proline Prosonic Flow B 200 Pulse/frequency/switch output Pulse output Failure mode Choose from: • Actual value • No pulses Frequency output Failure mode Choose from: • Actual value • Defined value: 0 to 1 250 Hz • 0 Hz Switch output Failure mode Choose from: • Current status • Open • Closed Local display Plain text display With information on cause and remedial measures Backlight Additionally for device version with SD03 local display: red lighting indicates a device error. Status signal as per NAMUR recommendation NE 107 Operating tool • Via digital communication: HART protocol • Via service interface Plain text display With information on cause and remedial measures Additional information on remote operation (® ä 36) Load Load for current output: 0 to 500 W, depending on the external supply voltage of the power supply unit Calculation of the maximum load Depending on the supply voltage of the power supply unit (US), the maximum load (RB) including line resistance must be observed to ensure adequate terminal voltage at the device. In doing so, observe the minimum terminal voltage (® ä 14) • For US = 16.0 to 16.8 V: RB £ (US - 16.0 V) : 0.0036 A • For US = 16.8 to 23.0 V: RB £ (US - 12.0 V) : 0.022 A • For US = 23.0 to 30.0 V: RB £ 500 W Endress+Hauser 9
  • 10. Proline Prosonic Flow B 200 Rb [W] 1 1.1 1.2 600 500 400 300 220 200 100 0 14 16 18 20 22 24 26 28 30 32 34 36 Us [V] 16.8 23 35 A0018972 1 Operating range 1.1 For order code for "Output", option A "4-20 mA HART"/option B "4-20 mA HART, pulse/frequency/switch output" with Ex i and option C "4-20 mA HART, 4-20 mA" 1.2 For order code for "Output", option A "4-20 mA HART"/option B "4-20 mA HART, pulse/frequency/switch output" with non-Ex and Ex d Sample calculation Supply voltage of the power supply unit: US = 17.5 V Maximum load: RB £ (17.5 V - 12.0 V) : 0.022 A = 250 W Ex connection data Safety-related values Ex d type of protection Order code for Output type Safety-related values "Output" Option A 4-20mA HART Unom = DC 35 V Umax = 250 V Option B 4-20mA HART Unom = DC 35 V Umax = 250 V Pulse/frequency/switch output Unom = DC 35 V Umax = 250 V Pmax = 1 W 1) 1) Internal circuit limited by Ri = 760.5 W Option C • 4-20mA HART Unom = DC 30 V • 4-20mA Umax = 250 V Type of protection XP Order code for Output type Safety-related values "Output" Option A 4-20mA HART Unom = DC 35 V Umax = 250 V Option B 4-20mA HART Unom = DC 35 V Umax = 250 V Pulse/frequency/switch output Unom = DC 35 V Umax = 250 V Pmax = 1 W 1) 1) Internal circuit limited by Ri = 760.5 W 10 Endress+Hauser
  • 11. Proline Prosonic Flow B 200 Option C • 4-20mA HART Unom = DC 30 V • 4-20mA Umax = 250 V Type of protection NI Order code for Output type Safety-related values "Output" Option A 4-20mA HART Unom = DC 35 V Option B 4-20mA HART Unom = DC 35 V Pulse/frequency/switch output Unom = DC 35 V Option C • 4-20mA HART Unom = DC 30 V • 4-20mA Type of protection NIFW Order code for Output type Intrinsically safe values "Output" Option A 4-20mA HART Ui = DC 35 V Ii = n.a. Pi = 1 W Li = 0 mH Ci = 5 nF Option B 4-20mA HART Ui = DC 35 V Ii = n.a. Pi = 1 W Li = 0 mH Ci = 5 nF Pulse/frequency/switch output Ui = DC 35 V Ii = n.a. Pi = 1 W Li = 0 mH Ci = 6 nF Option C • 4-20mA HART Ui = DC 30 V • 4-20mA Ii = n.a. Pi = 1 W Li = 0 mH Ci = 30 nF Intrinsically safe values type of protection Ex ia Order code for Output type Intrinsically safe values "Output" Option A 4-20mA HART Ui = DC 30 V Ii = 300 mA Pi = 1 W Li = 0 mH Ci = 5 nF Endress+Hauser 11
  • 12. Proline Prosonic Flow B 200 Option B 4-20mA HART Ui = DC 30 V Ii = 300 mA Pi = 1 W Li = 0 mH Ci = 5 nF Pulse/frequency/switch output Ui = DC 30 V Ii = 300 mA Pi = 1 W Li = 0 mH Ci = 6 nF Option C • 4-20mA HART Ui = DC 30 V • 4-20mA Ii = 300 mA Pi = 1 W Li = 0 mH Ci = 30 nF IS type of protection Order code for Output type Intrinsically safe values "Output" Option A 4-20mA HART Ui = DC 30 V Ii = 300 mA Pi = 1 W Li = 0 mH Ci = 5 nF Option B 4-20mA HART Ui = DC 30 V Ii = 300 mA Pi = 1 W Li = 0 mH Ci = 5 nF Pulse/frequency/switch output Ui = DC 30 V Ii = 300 mA Pi = 1 W Li = 0 mH Ci = 6 nF Option C • 4-20mA HART Ui = DC 30 V • 4-20mA Ii = 300 mA Pi = 1 W Li = 0 mH Ci = 30 nF Low flow cut off The switch points for low flow cut off are user-selectable. Galvanic isolation All outputs are galvanically isolated from one another. Protocol-specific data HART Manufacturer ID 0x11 Device type ID 0x5A HART protocol revision 6.0 Device description files (DTM, Information and files under: DD) www.endress.com 12 Endress+Hauser
  • 13. Proline Prosonic Flow B 200 HART load • Min. 250 Ω • Max. 500 W Dynamic variables The measured variables can be freely assigned to the dynamic variables. Measured variables for PV (primary dynamic variable) • Volume flow • Corrected volume flow • Corrected methane volume flow • Mass flow • Energy flow • Methane fraction • Gross calorific value • Wobbe index • Temperature Measured variables for SV, TV, QV (secondary, tertiary and quaternary dynamic variable) • Volume flow • Corrected volume flow • Corrected methane volume flow • Mass flow • Energy flow • Methane fraction • Gross calorific value • Wobbe index • Temperature • Totalizer 1 • Totalizer 2 • Totalizer 3 Power supply Terminal assignment Transmitter Connection versions 2 1 3 2 1 3 + – + – 3 4 1 2 + – + – 3 4 1 2 A0013570 A0018161 Maximum number of terminals, without integrated Maximum number of terminals, with integrated overvoltage protection overvoltage protection 1 Output 1 (passive): supply voltage and signal transmission 2 Output 2 (passive): supply voltage and signal transmission 3 Ground terminal for cable shield Order code for Terminal numbers "Output" Output 1 Output 2 1 (+) 2 (-) 3 (+) 4 (-) Option A 4-20 mA HART (passive) - Option B 1) 4-20 mA HART (passive) Pulse/frequency/switch output (passive) Endress+Hauser 13
  • 14. Proline Prosonic Flow B 200 Option C 1) 4-20 mA HART (passive) 4-20 mA (passive) 1) Output 1 must always be used; output 2 is optional. Supply voltage An external power supply is required for each output. The following supply voltage values apply for the 4-20 mA and 4-20 mA HART current output: Order code for Minimum Maximum "Output" terminal voltage terminal voltage • Option A 1), 2): 4-20 mA HART For 4 mA: ³ DC 16 V DC 35 V • Option B 1), 2): 4-20 mA HART, For 20 mA: ³ DC 12 V Pulse/frequency/switch output Option C 1), 2): 4-20 mA HART, For 4 mA: ³ DC 16 V DC 30 V 4-20 mA For 20 mA: ³ DC 12 V 1) External supply voltage of the power supply unit with load (® ä 9) 2) For device versions with local display SD03: The terminal voltage must be increased by DC 2 V if backlighting is used. For information on the Ex connection values (® ä 10) Various power supply units can be ordered from Endress+Hauser: see "Accessories" section (® ä 41) Power consumption Transmitter Order code for Maximum power consumption "Output" Option A: 4-20 mA HART 770 mW Option B: 4-20 mA HART, • Operation with output 1: 770 mW Pulse/frequency/switch output • Operation with output 1 and 2: 2 770 mW Option C: 4-20 mA HART, 4-20 mA • Operation with output 1: 660 mW • Operation with output 1 and 2: 1 320 mW For information on the Ex connection values (® ä 10) Current consumption Current output For every 4-20 mA or 4-20 mA HART current output: 3.6 to 22.5 mA If the option Defined value is selected in the Failure mode parameter (® ä 8): 3.59 to 22.5 mA Power supply failure • Totalizers stop at the last value measured. • Configuration is retained in the device memory (HistoROM). • Error messages (incl. total operated hours) are stored. 14 Endress+Hauser
  • 15. Proline Prosonic Flow B 200 Electrical connection Connecting the transmitter 2 1 A0015510 1 Cable entry for output 1 2 Cable entry for output 2 Connection examples 1 2 3 4 5 6 4...20 mA + + 7 - - A0015511 å2 Connection example for 4-20 mA HART current output (passive) 1 Automation system with current input (e.g. PLC) 2 Active barrier for power supply (e.g. RN221N) (® ä 17) 3 Observe cable specification (® ä 17) 4 Resistor for HART communication (³ 250 W): observe maximum load (® ä 9) 5 Connection for HART operating devices (® ä 36) 6 Analog display unit: observe maximum load (® ä 9) 7 Transmitter 1 2 3 + 4...20 mA + + 4 - - – A0015512 å3 Connection example for 4-20 mA current output (passive) 1 Automation system with current input (e.g. PLC) 2 Active barrier for power supply (e.g. RN221N) (® ä 14) 3 Analog display unit: observe maximum load (® ä 9) 4 Transmitter Endress+Hauser 15
  • 16. Proline Prosonic Flow B 200 1 2 – + _ + – 3 + 12345 A0016801 å4 Connection example for pulse/frequency output (passive) 1 Automation system with pulse/frequency input (e.g. PLC) 2 Power supply 3 Transmitter: Observe input values (® ä 7) 1 2 _ + _ + _ 3 + A0016802 å5 Connection example for switch output (passive) 1 Control system with switch input (e.g. PLC) 2 Power supply 3 Transmitter: Observe input values (® ä 7) 1 2 3 4 5 4...20 mA + + + – – 7 + - – – + + + + – – 6 - 3 4 A0016029 å6 Connection example for HART input with a common negative 1 Automation system with HART output (e.g. PLC) 2 Resistor for HART communication (³ 250 W): observe maximum load (® ä 9) 3 Active barrier for power supply (e.g. RN221N) (® ä 14) 4 Observe cable specification (® ä 17) 5 Analog display unit: observe maximum load (® ä 9) 6 Pressure transmitter (e.g. Cerabar M, Cerabar S): see requirements (® ä 7) 7 Transmitter 16 Endress+Hauser
  • 17. Proline Prosonic Flow B 200 Potential equalization No special measures for potential equalization are required. For devices in hazardous locations, please observe the guidelines in the Ex documentation (XA). Terminals • For device version without integrated overvoltage protection: plug-in spring terminals for wire cross- sections 0.5 to 2.5 mm2 (20 to 14 AWG) • For device version with integrated overvoltage protection: screw terminals for wire cross-sections 0.2 to 2.5 mm2 (24 to 14 AWG) Cable entries • Cable gland (not for Ex d): M20 × 1.5 with cable Æ 6 to 12 mm (0.24 to 0.47 in) • Thread for cable entry: – For non-Ex and Ex: NPT ½" – For non-Ex and Ex (not for CSA Ex d/XP): G ½" – For Ex d: M20 × 1.5 Cable specification Permitted temperature range • –40 °C (–40 °F)...³ 80 °C (176 °F) • Minimum requirement: cable temperature range ³ ambient temperature + 20 K Signal cable Current output • For 4-20 mA: standard installation cable is sufficient. • For 4-20 mA HART: Shielded cable recommended. Observe grounding concept of the plant. Pulse/frequency/switch output Standard installation cable is sufficient. Overvoltage protection The device can be ordered with integrated overvoltage protection for diverse approvals: Order code for "Accessory mounted", option NA "overvoltage protection" Input voltage range Values correspond to supply voltage specifications (® ä 14) 1) Resistance per channel 2 × 0.5 W max DC sparkover voltage 400 to 700 V Trip surge voltage < 800 V Capacitance at 1 MHz < 1.5 pF Nominal discharge current (8/20 10 kA ms) Temperature range –40 to +85 °C (–40 to +185 °F) 1) The voltage is reduced by the amount of the internal resistance Imin × Ri Depending on the temperature class, restrictions apply to the ambient temperature for device versions with overvoltage protection . Performance characteristics Reference conditions • Error limits following ISO/DIS 11631 • Calibration gas: air • Temperature regulated to 24 ± 0.5 °C (75.2 ± 0.9 °F) under atmospheric pressure • Humidity regulated to < 40 % RH • Accuracy based on accredited calibration rigs that are traced to ISO 17025. To calculate the measuring range, use the Applicator sizing tool (® ä 41) Endress+Hauser 17
  • 18. Proline Prosonic Flow B 200 Maximum measured error In addition to the values indicated, the measured error at the current output is typically ±4 mA. o.r. = of reading; o.f.s. = of full scale value; abs. = absolute; 1 g/cm3 = 1 kg/l; T = medium temperature Volume flow Standard • ±1.5 % o.r. for 3 to 30 m/s (9.84 to 98.4 ft/s) Order code for "Calibration", option 1 • ±3 % o.r. for 1 to 3 m/s (3.28 to 9.84 ft/s) Optional • ±0.1 % o.f.s. for 0.3 to 1 m/s (0.98 to 3.28 ft/s) Order code for "Calibration", option 2 • ±1.5 % o.r. for 1 to 30 m/s (3.28 to 98.4 ft/s) Methane ±2 % o.f.s. = ±2 % abs. Temperature ±0.6 °C ± 0.005 × T °C (±0.9 °F ± 0.005 × (T – 32) °F) Example for max. measured error (volume flow) [%] 10.0 9.0 8.0 2 7.0 6.0 1 5.0 4.0 3.0 2.0 1.0 0 0 1 2 3 4 5 6 7 8 30 [m/s] v 0 5 10 15 20 25 100 [ft/s] A0015541 å7 Example for max. measured error (volume flow) in % o.r. 1 Standard (order code for "Calibration", option 1) 2 Optional (order code for "Calibration", option 2) Repeatability o.r. = of reading; o.f.s. = of full scale value; abs. = absolute; 1 g/cm3 = 1 kg/l; T = medium temperature Volume flow ±0.5 % o.r. Methane ±0.5 % o.f.s. = ±0.5 % abs. Temperature ±0.3 °C ± 0.0025 × T °C (±0.45 °F ± 0.0025 × (T – 32) °F) Response time • The response time depends on the configuration (damping). • Response time in the event of erratic changes in the flow: after 1 000 ms 95 % of the full scale value. Influence of ambient o.r. = of reading; o.f.s. = of full scale value temperature Current output Additional error, in relation to the span of 16 mA: 18 Endress+Hauser
  • 19. Proline Prosonic Flow B 200 Temperature coefficient at 0.02 %/10 K, max. 0.35 % over the entire temperature range zero point (4 mA) –40 to +60 °C (–40 to +140 °F) Temperature coefficient 0.05 %/10 K, max. 0.5 % over the entire temperature range with span (20 mA) –40 to +60 °C (–40 to +140 °F) Pulse/frequency output Temperature coefficient Max. ±100 ppm o.r. Installation No special measures such as supports are necessary. External forces are absorbed by the construction of the device. Mounting location A0015543 Orientation The direction of the arrow on the sensor helps you to install the sensor according to the flow direction (direction of medium flow through the piping). • Install the measuring device in a parallel plane free of external mechanical stress. • The internal diameter of the pipe must match the internal diameter of the sensor (® ä 26). A0015895 Orientation Compact version A Vertical orientation A0015545 B Horizontal orientation, transmitter head up * A0015589 Endress+Hauser 19
  • 20. Proline Prosonic Flow B 200 Orientation Compact version C Horizontal orientation, transmitter head down * A0015590 D Horizontal orientation, transmitter head at side A0015592 * A maximum deviation of only ±3 ° is permitted for the horizontal alignment of the transducers. –3° 0° –3° +3° 0° +3° A0016534 Inlet and outlet runs The sensor should be mounted upstream of assemblies such as valves, T-sections, elbows etc. where possible. As a minimum, the inlet and outlet runs shown below must be observed to achieve the specific accuracy of the device. The longest inlet run shown must be observed if two or more flow disturbances are present. Single-path version: DN 50 (2"), DN 80 (3") A B 1 2 1 2 20 × DN 3 × DN 20 × DN 3 × DN C D 1 2 1 2 20 × DN 3 × DN 20 × DN 3 × DN A0015453 å8 Single-path version: minimum inlet and outlet runs with various flow obstructions A 90 ° elbow or T-section B Pump C 2× 90 ° elbow 3-dimensional D Control valve 1 Inlet run 2 Outlet run 20 Endress+Hauser
  • 21. Proline Prosonic Flow B 200 Two-path version: DN 100 to 200 (4 to 8") A B 1 2 1 2 10 × DN 3 × DN 10 × DN 3 × DN C D 1 2 1 2 10 × DN 3 × DN 10 × DN 3 × DN A0015553 å9 Two-path version: minimum inlet and outlet runs with various flow obstructions A 90 ° elbow or T-section B Pump C 2× 90 ° elbow 3-dimensional D Control valve 1 Inlet run 2 Outlet run Special mounting instructions Outlet run for pressure transmitter If a pressure transmitter is installed downstream of the measuring device, make sure there is sufficient distance between the two devices. PT 3 × DN A0015901 PT Pressure transmitter Flow conditioner It is advisable to use a flow conditioner if the inlet runs cannot be observed. Using a flow conditioner reduces the inlet required as follows: Single-path version Two-path version 10 × DN 5 × DN The flow conditioner should be installed so that it divides the available inlet run by a ratio of roughly 20 : 80. Example for an inlet run of 10 × DN: 1 2 × DN 8 × DN 10 × DN A0015562 1 Flow conditioner Endress+Hauser 21
  • 22. Proline Prosonic Flow B 200 Pressure loss The pressure loss for flow conditioners is calculated as follows: Dp [mbar] = 0.0085 · r [kg/m3] · v2 [m/s] Example for biogas p = 1 040 mbar abs. r = 1.0432 kg/m3 at t = 54 °C (129 °F) v = 7 m/s Dp = 0.0085 · 1.0432 kg/m3 · 49 m/s = 0.434 mbar --- abs.: absolute r: density of the process medium v: average flow velocity Environment Ambient temperature range Transmitter –40 to +60 °C (–40 to +140 °F) Local display –20 to +60 °C (–4 to +140 °F), the readability of the display may be impaired at temperatures outside the temperature range. Sensor • Flange material carbon steel: –10 to +60 °C (+14 to +140 °F) • Flange material stainless steel: –40 to +60 °C (–40 to +140 °F) • Version without flange: –40 to +60 °C (–40 to +140 °F) ► If operating outdoors: Avoid direct sunlight, particularly in warm climatic regions. Weather protection covers can be ordered from Endress+Hauser: see "Accessories" section (® ä 39) Temperature tables The following interdependencies between the permitted ambient and fluid temperatures apply when operating the device in hazardous areas: The following applies for installations with overvoltage protection in conjunction with approval code BJ or IJ: Ta = Ta - 2 °C (Ta = Ta - 3.6 °F) Order code for "Output", option A "4-20mA HART" Ex ia, Ex d, CCSAUS IS, CCSAUS XP, CCSAUS NI SI units Nominal diameter Ta T6 T5 T4 T3 T2 T1 [mm] [°C] [85 °C] [100 °C] [135 °C] [200 °C] [300 °C] [450 °C] 50 to 200 40 60 80 80 80 80 80 50 to 200 50 – 80 80 80 80 80 50 to 200 60 – 80 80 80 80 80 US units Nominal diameter Ta T6 T5 T4 T3 T2 T1 [in] [°F] [185 °F] [212 °F] [275 °F] [392 °F] [572 °F] [842 °F] 2 to 8 104 140 176 176 176 176 176 2 to 8 122 – 176 176 176 176 176 2 to 8 140 – 176 176 176 176 176 22 Endress+Hauser
  • 23. Proline Prosonic Flow B 200 Order code for "Output", option B "4-20mA HART, pulse/frequency/switch output" Ex ia, Ex d, CCSAUS IS, CCSAUS XP, CCSAUS NI SI units Nominal diameter Ta T6 T5 T4 T3 T2 T1 [mm] [°C] [85 °C] [100 °C] [135 °C] [200 °C] [300 °C] [450 °C] 50 to 200 40 – 1) 80 80 80 80 80 2) 50 to 200 50 – 60 80 80 80 80 50 to 200 60 – – 80 80 80 80 1) Ta = 60 °C for pulse/frequency/switch output Pi £ 0.85 W 2) Ta = 80 °C for pulse/frequency/switch output Pi £ 0.85 W US units Nominal diameter Ta T6 T5 T4 T3 T2 T1 [in] [°F] [185 °F] [212 °F] [275 °F] [392 °F] [572 °F] [842 °F] 2 to 8 104 – 1) 176 176 176 176 176 2 to 8 122 – 140 2) 176 176 176 176 2 to 8 140 – – 176 176 176 176 1) Ta = 140 °F for pulse/frequency/switch output Pi £ 0.85 W 2) Ta = 176 °F for pulse/frequency/switch output Pi £ 0.85 W Order code for "Output", option C "4-20mA HART, 4-20mA" Ex ia, Ex d, CCSAUS IS, CCSAUS XP, CCSAUS NI SI units Nominal diameter Ta T6 T5 T4 T3 T2 T1 [mm] [°C] [85 °C] [100 °C] [135 °C] [200 °C] [300 °C] [450 °C] 50 to 200 40 60 80 80 80 80 80 50 to 200 50 – 80 80 80 80 80 50 to 200 60 – 55 80 80 80 80 US units Nominal diameter Ta T6 T5 T4 T3 T2 T1 [in] [°F] [185 °F] [212 °F] [275 °F] [392 °F] [572 °F] [842 °F] 2 to 8 104 140 176 176 176 176 176 2 to 8 122 – 176 176 176 176 176 2 to 8 140 – 131 176 176 176 176 Storage temperature –40 to +80 °C (–40 to +176 °F), preferably at +20 °C (+68 °F) Degree of protection Transmitter • As standard: IP66/67, type 4X enclosure • When housing is open: IP20, type 1 enclosure • Display module: IP22, type 1 enclosure Sensor IP66/67, type 4X enclosure Shock resistance In accordance with EN 60721-3-4 Endress+Hauser 23
  • 24. Proline Prosonic Flow B 200 Vibration resistance Class 4M4, in accordance with EN 60721-3-4 Electromagnetic compatibility • As per IEC/EN 61326 and NAMUR Recommendation 21 (NE 21) (EMC) • Complies with emission limits for industry as per EN 55011 Details are provided in the Declaration of Conformity. Process Medium temperature range Sensor 0 to +80 °C (+32 to +176 °F) Pressure-temperature ratings The following material load diagrams refer to the entire device and not just the process connection. Flange connection according to EN 1092-1 (DIN 2501) [psi] [bar] 300 20 200 100 10 0 0 0 20 40 60 80 100 [°C] 40 80 120 160 200 [°F] A0015905 å 10 With lap joint flange, stamped plate PN 10, material 1.4301/304 (DN 50 to 200 / 2 to 8") Flange connection according to EN 1092-1 (DIN 2501) [psi] [bar] 300 20 200 100 10 0 0 0 20 40 60 80 100 [°C] 40 80 120 160 200 [°F] A0015906 å 11 With lap joint flange PN 10, material 1.4306/304L (DN 200 / 8") Flange connection according to EN 1092-1 (DIN 2501) [psi] [bar] 300 20 200 100 10 0 0 0 20 40 60 80 100 [°C] 40 80 120 160 200 [°F] A0015932 å 12 With lap joint flange PN 10/16, materials S235JR (DN 50 to 200 / 2 to 8") and 1.4306/304L (DN 50 to 150 / 2 to 6"); With lap joint flange, stamped plate PN 10, material S235JR (DN 50 to 200 / 2 to 8") 24 Endress+Hauser
  • 25. Proline Prosonic Flow B 200 Flange connection according to ASME B16.5 [psi] [bar] 300 20 200 100 10 0 0 0 20 40 60 80 100 [°C] 40 80 120 160 200 [°F] A0015568 å 13 With lap joint flange Class 150, materials 1.4404/316L and A105 (DN 50 to 200 / 2 to 8") Flow limit Select the nominal diameter by optimizing between the required flow range and permissible pressure loss. For an overview of the measuring range full scale values, see the "Measuring range" section (® ä 6) • The minimum recommended full scale value is approx. 1/20 of the maximum full scale value. • In most applications, 10 to 50 % of the maximum full scale value can be considered ideal. Pressure loss There is no pressure loss. System pressure Sensor Max. 10 bar (145 psi) Thermal insulation For optimum temperature and methane fraction measurement (order characteristic for "Sensor version", option 2 "Volume flow + Biogas analysis"), make sure that heat is neither lost nor applied to the sensor. Thermal insulation can ensure that such heat transfer does not take place. Thermal insulation is particularly recommended in situations where there is a large difference between the process temperature and the ambient temperature. This can result in heat convection errors during temperature measurement. A further factor which can lead to measurement errors due to heat convection is a low flow velocity. Mechanical construction Design, dimensions Compact version Order code for "Housing", options C "GT20 two-chamber, aluminum coated" , S "GT18 two-chamber, stainless steel" Endress+Hauser 25