Dong IL Paper Mfg., Co., Ltd.
                                                                                                             BM 1, (KURKI)
Air Systems/H. Suikki/PNä                             December 14, 2007                                                     i




                                   4 OPERATING INSTRUCTIONS


1               AIR DRYERS .......................................................................................................... 1

                1.1     Air dryer for board grades .............................................................................. 1
                        1.1.1     The operation principle .................................................................... 1
                        1.1.2     Retraction and supporting devices .................................................. 2
                        1.1.3     Circulation air equipment ................................................................. 4
                        1.1.4     Gas burner ....................................................................................... 5
                        1.1.5     Burner output / combustion air regulation ........................................ 5
                        1.1.6     Burner control .................................................................................. 6
                        1.1.7     Operational conditions and interlockings for burner ........................ 6
                        1.1.8     Automatic purging in normal circulation condition ........................... 7
                        1.1.9     Operation during web break. Short circulation equipment ............... 8
                        1.1.10 Preheating ....................................................................................... 8
                        1.1.11 Exhaust air equipment ..................................................................... 9
                        1.1.12 Make-up air equipment .................................................................... 9
                        1.1.13 Alarms ............................................................................................. 9
                        1.1.14 Maintenance .................................................................................. 10

2               VENTILATION EQUIPMENT OF INFRARED DRYERS ....................................... 12

                2.1     Ventilation equipment for gas-heated infrared dryers .................................. 12
                        2.1.1     Combustion air .............................................................................. 13
                        2.1.2     Circulation air ................................................................................. 13
                        2.1.3     Interlockings .................................................................................. 14




PowerDry Classic air dryers                                                                            4 Operating instructions
Q:AsiakasprojektitM00227KURKI700 PDF_ Operating and maintenance manual04 Operating
instructionsOperating_instructions.doc
Dong IL Paper Mfg., Co., Ltd.
                                                                                                  BM 1, (KURKI)
Air Systems/H. Suikki/PNä                        December 14, 2007                                              1


1       AIR DRYERS


1.1     Air dryer for board grades

1.1.1 The operation principle

                                The hot circulation air is fed to the nozzles through the ductwork in
                                the air dryer box. The nozzles are near the paper web. Hot air is
                                blown towards the web through slots which are crosswise in view of
                                the paper web.

                                The air dryer boxes consists of boxes, under which the paper web is
                                going and the retraction and supporting device for opening the
                                boxes.




                                                                                     Hot blowing air to the air dryer




                                                                                                Humid air back to
                                                                                                circulation air ducts




                                                          Air distribution ducts
                       Blowing nozzles



                                Figure 1         Air dryer box


                                The air dryer nozzles are of Impingement type.




PowerDry Classic air dryers                                                               4 Operating instructions
Q:AsiakasprojektitM00227KURKI700 PDF_ Operating and maintenance manual04 Operating
instructionsOperating_instructions.doc
Dong IL Paper Mfg., Co., Ltd.
                                                                                                  BM 1, (KURKI)
Air Systems/H. Suikki/PNä                        December 14, 2007                                              2




                                Figure 2         Impingement nozzle


                                This cooled and humid air is extracted between the blowing nozzles
                                into the air dryer box where it is led by ducts outside the air dryer
                                and into the circulation air ductwork.

                                There are perforated plates between the blowing nozzles to prevent
                                bits of paper from going into the circulation air.

1.1.2 Retraction and supporting devices

                                The nozzle surfaces of the air dryer are very close to the paper web
                                when operating. The air dryer boxes can be opened for tail
                                threading, cleaning and maintenance.

                                The air dryers are equipped with pneumatic hoisting cylinders which
                                can move the air dryer away from the web.

                                For cleaning of the nozzle area the tending side edge of the air dryer
                                can be hoisted 200 mm.

                                The air dryers open automatically after the web break.

                                In the automatic system the air dryer can be opened and closed.
                                Pre-alarm with electric bell will be given before retraction.



PowerDry Classic air dryers                                                               4 Operating instructions
Q:AsiakasprojektitM00227KURKI700 PDF_ Operating and maintenance manual04 Operating
instructionsOperating_instructions.doc
Dong IL Paper Mfg., Co., Ltd.
                                                                                                  BM 1, (KURKI)
Air Systems/H. Suikki/PNä                        December 14, 2007                                              3

                                Each air dryer has sensors which inform the automation system of
                                the close position of the air dryer.

                                The supporting devices are equipped with manual mechanical safety
                                locks by which the air dryers can be locked in the open position.

                                CLOSING THE AIR DRYERS CAN BE PREVENTED BY A
                                MANUAL MECHANICAL SAFETY LOCKING DEVICE. SAFETY
                                LOCKING MUST ALWAYS BE USED IF ONE ENTERS BETWEEN
                                THE OPEN AIR DRYER.




                                              Cylinder




                                                                                Air
                                                                                Dryer




                                          Locked              Open




                                Figure 3         Manual mechanical safety locks




PowerDry Classic air dryers                                                               4 Operating instructions
Q:AsiakasprojektitM00227KURKI700 PDF_ Operating and maintenance manual04 Operating
instructionsOperating_instructions.doc
Dong IL Paper Mfg., Co., Ltd.
                                                                                                  BM 1, (KURKI)
Air Systems/H. Suikki/PNä                        December 14, 2007                                              4

1.1.3 Circulation air equipment

                                The circulation air is taken from the return air (humid air) duct of the
                                dryer and led to the circulation air fan. By the fan the circulation air is
                                blown through the burner to the air dryer.


                Circulation air ductwork

                                The circulation air duct is connected by exhaust and make-up air
                                equipment which discharge the humid circulation air and bring in
                                drier air.

                                The supply and return sides of the circulation air duct are connected
                                by a by-pass duct before the air dryer. In the by-pass duct and in the
                                circulation air duct on the supply and return sides there are dampers
                                equipped with an actuator. These dampers prevent the circulation air
                                from flowing into the air dryer during a web break. There is a more
                                detailed function description in Section "Operation during web break.
                                Short circulation equipment".


                Circulation air fan

                                The circulation air fan can be started and stopped in manual mode, if
                                the combustion air fan is running. If the fan is in AUTO mode the fan
                                can be started by using group start function, in that case the fan
                                starts after certain delay when exhaust fan and combustion air fan
                                are running.

                                The blowing velocity in the air dryer nozzle affects the air dryer
                                evaporation efficiency. The circulation fan has an inlet vane control
                                damper. Its set value can be changed to change the blowing
                                velocity.


                Inlet vane control damper

                                The inlet vane control damper is closed when the circulation air fan
                                stops. The automation system also opens the inlet vane control
                                damper with a short delay to the set value after the start.




PowerDry Classic air dryers                                                               4 Operating instructions
Q:AsiakasprojektitM00227KURKI700 PDF_ Operating and maintenance manual04 Operating
instructionsOperating_instructions.doc
Dong IL Paper Mfg., Co., Ltd.
                                                                                                  BM 1, (KURKI)
Air Systems/H. Suikki/PNä                        December 14, 2007                                              5


1.1.4 Gas burner

                                The gas burner is installed near the fan in the circulation air
                                ductwork. It is a duct type burner where the expanded part of duct is
                                equipped with a burner head composed of modules, a lighter, flame
                                control equipment and a combustion air duct.

                                Gas is brought to the burner through a special safety valve group
                                whose safety, ignition and flame control functions are automatically
                                operated by the control logic of the burner.

                                Gas needs enough oxygen for complete combustion. The burner is
                                equipped with a combustion air fan which takes air from the fan area
                                and blows it to the burner.

1.1.5 Burner output / combustion air regulation

                                The temperature of the air blown in the air dryer affects the
                                evaporation efficiency of the air dryer.

                                The burner output is changed by an actuator which regulates gas
                                amount.

                                The circulation air temperature of the air dryer is regulated by
                                changing the burner output by gas control valve.

                                Burner needs constant combustion air pressure and there is
                                pressure control loop in automation system. Setpoint for pressure is
                                fixed and operator can´t change it.


                Short circulation

                                When the short air circuit is in use (web break, service) the control
                                circuit of the circulation air temperature gets it’s measurement value
                                from the temperature sensor after burner in the circulation air
                                ductwork. The control system force the setpoint of air temperature to
                                100 °C during the short circuit.




PowerDry Classic air dryers                                                               4 Operating instructions
Q:AsiakasprojektitM00227KURKI700 PDF_ Operating and maintenance manual04 Operating
instructionsOperating_instructions.doc
Dong IL Paper Mfg., Co., Ltd.
                                                                                                  BM 1, (KURKI)
Air Systems/H. Suikki/PNä                        December 14, 2007                                              6




                Normal operation circulation

                                During normal operation and pre-heating period when the air dryer is
                                closed the control circuit of the circulation air temperature gets it’s
                                measurement value from the temperature sensor in air dryer. The
                                temperature sensor in the circulation air ductwork serves as a
                                temperature limit sensor. The maximum air temperature is 350 °C.

                                The automation system measures the circulation supply air
                                temperature for the normal operation and the temperature can be
                                read in the display of the automation system.

1.1.6 Burner control

                                The burner can be started and stopped either locally in the burner
                                control box or alternatively in the automation system. The choice of
                                the burner control, local / remote, is made in the burner control
                                panel.

                                Failures can also be reset either locally or in the automation system.
                                There are signal lights for different failures in the burner control
                                panel and all the failure information is given as alarms to the
                                automation system.

1.1.7 Operational conditions and interlockings for burner
                                 1   Emergency stop closes the gas safety locking valves and thus
                                     stops the burners.
                                 2   The burner is ready to start if:
                                     −    the exhaust air pressure is sufficient
                                     −    the combustion air pressure is sufficient
                                     −    the circulation air pressure is sufficient
                                     −    (i.e. the fans are really running)
                                     −    the temperature after the burner is under the pre-set
                                          maximum limit
                                     −    the gas pressure is over the pre-set minimum limit
                                     −    the gas pressure is under the pre-set maximum limit
                                     −    the pre-purging        sequence       is proceeding      without any
                                          interruption


PowerDry Classic air dryers                                                               4 Operating instructions
Q:AsiakasprojektitM00227KURKI700 PDF_ Operating and maintenance manual04 Operating
instructionsOperating_instructions.doc
Dong IL Paper Mfg., Co., Ltd.
                                                                                                  BM 1, (KURKI)
Air Systems/H. Suikki/PNä                        December 14, 2007                                              7

                                 3   The burner starts (ignites) if:
                                     −    the pre-purging sequence has been completed
                                     −    the gas control valve is in min. position (low fire position)
                                     −    the flame scanner is working
                                     −    the selection switch in local burner panel is in local position
                                          or, in case the selection switch is in remote position, DCS
                                          program control “burner ready to start”
                                 4   The burner starts automatically after "burner ready to start" mode
                                     has been achieved (pre-purging completed).
                                 5   The burner is working (burns) if:
                                     −    the flame scanner continuously recognizes a flame
                                     −    the "pre-purging completed" - information is continuously
                                          valid
                                     −    the burner control internal failure checkings are not indicating
                                          malfunctions

                                 If any of the operating conditions mentioned above is not at hand,
                                 the running burner is shut off or the ignition sequence is interrupted
                                 and the signal lamp in the control panel of the burner shows the
                                 actual failure. When the burner shuts off the gas valve automatically
                                 moves into the minimum position.

                                 In case of web break the burner control valves move to low fire
                                 position.

                                 When the burner has ignited and burns with minimum flame (low fire
                                 position), a signal lamp is lit and the burner effect can be adjusted,
                                 by regulating the main gas valve, to the desired level.

1.1.8 Automatic purging in normal circulation condition

                                Before the burners can be ignited locally or remote, a so called pre-
                                purging has to be carried out, by which any possible gas in the
                                circulation air ductwork is exhausted. The pre-purging sequence
                                takes ab. 60 seconds. The burner must continuously get the "pre-
                                purging done" signal in order to burn.




PowerDry Classic air dryers                                                               4 Operating instructions
Q:AsiakasprojektitM00227KURKI700 PDF_ Operating and maintenance manual04 Operating
instructionsOperating_instructions.doc
Dong IL Paper Mfg., Co., Ltd.
                                                                                                  BM 1, (KURKI)
Air Systems/H. Suikki/PNä                        December 14, 2007                                              8


                                The one-minute pre-purging for normal circulation starts
                                automatically when the exhaust air, the circulation air and
                                combustion air fans are running. During the pre-purging the shut-off
                                dampers opens and by-pass dampers closes automatically (so
                                called long circulation), the exhaust air damper opens 100% and the
                                circulation air damper opens 100 %.

                                If these conditions are fulfilled during the pre-purging sequence, the
                                condition "pre-purging done" is valid.

                                The "Pre-purging done" condition has to be valid in order to be able
                                to ignite the burners and to run them.

                                The "Pre-purging done" condition disappears if the combustion, the
                                exhaust, or circulation air fan stops. A new pre-purging of the system
                                must then be carried out by starting the fan which has been stopped.

1.1.9 Operation during web break. Short circulation equipment

                                The starting routines of the burner take several minutes due to the
                                control and purging operations connected with the gas burner. In
                                order to avoid unnecessary delays, it is practical to keep the gas
                                burner and the air circulation running during short breaks.

                                Web break opens the air dryers and the system goes to the short
                                circulation.

                                During the tail threading the air flows in short circulation circuit
                                (through the by-pass duct to the inlet side of the circulation air fan),
                                preventing it from blowing into the air dryer.

1.1.10 Preheating

                                After a longer production stop the air dryer boxes have to be warmed
                                up before tail threading.

                                Preheating is operated from the air dryer display.

                                The operator gives the temperature set value and preheating
                                temperature set value from the display.

                                Air dryer ready for coating information is displayed in the air dryer
                                display and it is one condition of station ready for coating which is
                                indicated with signal lamp in the control box.



PowerDry Classic air dryers                                                               4 Operating instructions
Q:AsiakasprojektitM00227KURKI700 PDF_ Operating and maintenance manual04 Operating
instructionsOperating_instructions.doc
Dong IL Paper Mfg., Co., Ltd.
                                                                                                  BM 1, (KURKI)
Air Systems/H. Suikki/PNä                        December 14, 2007                                              9

1.1.11 Exhaust air equipment

                                When returning from the air dryer, the circulation air has cooled and
                                the water evaporated from the web inside the air dryer has mixed
                                with the air. To ensure a stable water content in the circulation air,
                                the water picked up by evaporation must be removed before the air
                                is blown back into the air dryer.

                                Circulation air is "dried" by exhausting a certain amount of humid
                                return air, removing the water mixed with it.

                                There is one common exhaust air fan at coating station. The exhaust
                                air is taken from the circulation air duct and led directly outdoors.

                                The exhaust air amount is regulated with the damper of the exhaust
                                air duct. The leakage air temperature corrects the air amount.

                                If the fans are started with group start, the exhaust air fan will start
                                first of all fans.The exhaust air fans can be started and stopped in
                                manual mode without any interlockings.

1.1.12 Make-up air equipment

                                The exhaust air is replaced by drier air. The make-up air is sucked
                                directly from the mezzanine floor into the circulation air system. The
                                duct is equipped with a local manual control damper.

1.1.13 Alarms
                                 •   Circulation air fan
                                     −    Circulation air fan MCC failure
                                 •   Circulation air temperature control
                                     −    air dryer temperature too high
                                 •   Circulation air temperature before fan/burner
                                     −    temperature too high
                                 •   Combustion air fan
                                     −    Combustion air fan MCC failure
                                 •   Exhaust air fan
                                     −    Exhaust air fan MCC failure




PowerDry Classic air dryers                                                               4 Operating instructions
Q:AsiakasprojektitM00227KURKI700 PDF_ Operating and maintenance manual04 Operating
instructionsOperating_instructions.doc
Dong IL Paper Mfg., Co., Ltd.
                                                                                                  BM 1, (KURKI)
Air Systems/H. Suikki/PNä                        December 14, 2007                                             10


                                 •   Burner control
                                     −    high temperature
                                     −    low gas pressure
                                     −    high gas pressure
                                     −    low process air pressure
                                     −    low exhaust air pressure
                                     −    low combustion air pressure
                                     −    low fire micro switch open
                                     −    flame off
                                     −    emergency switch
                                     −    burner in operation
                                     −    burner in local control
                                 •   Air dryer retraction
                                     −    time alarm if the top box does not close or open in valid time
                                     −    pre-alarm with electric bell will be given before retraction

1.1.14 Maintenance


                Cleaning

                                To ensure fire safety and faultless operation, the air dryer and the
                                blowing nozzles must be kept clean both outside and inside.

                                The outside of air dryer is washed clean. The inside is blown by
                                pressurized air.

                                The blowing nozzles and the suction holes must be cleaned as soon
                                as they have got dirty. They are cleaned by a brush or a wet sponge.
                                It is not recommended to clean them by a water jet because hot
                                metal parts may be damaged. If the nozzles are blocked, problems
                                can occur in the coating. Therefore the nozzles must be cleaned at
                                every washing shutdown.

                                The nozzle surfaces must not be scratched.




PowerDry Classic air dryers                                                               4 Operating instructions
Q:AsiakasprojektitM00227KURKI700 PDF_ Operating and maintenance manual04 Operating
instructionsOperating_instructions.doc
Dong IL Paper Mfg., Co., Ltd.
                                                                                                  BM 1, (KURKI)
Air Systems/H. Suikki/PNä                        December 14, 2007                                             11

                Control and regulationof an air dryer

                                The following things must be checked at least four times a year:
                                 •   The air dryers moven open/shut without obstacles both when
                                     cold and when operating.
                                 •   The air dryer is in the closed position against stoppers so that the
                                     clearance in the drawing is in the attaching parts of pneumatic
                                     cylinders.
                                 •   Heat expansion of the air dryer has no obstacles across the web
                                     on the tending side.
                                 •   The safety locking mechanism for the open position of the air
                                     dryer works well.
                                 •   The nozzle surfaces are clean.




PowerDry Classic air dryers                                                               4 Operating instructions
Q:AsiakasprojektitM00227KURKI700 PDF_ Operating and maintenance manual04 Operating
instructionsOperating_instructions.doc
Dong IL Paper Mfg., Co., Ltd.
                                                                                                  BM 1, (KURKI)
Air Systems/H. Suikki/PNä                        December 14, 2007                                             12


2       VENTILATION EQUIPMENT OF INFRARED DRYERS


                                Infrared dryers are used for heating a certain material aglow. The
                                glowing surface placed near the paper web transfers its heat energy
                                by emission to the water in the paper.

                                The temperature of the moist paper web can be raised quickly by
                                means of the big energy transfer of the infrared dryer.

2.1     Ventilation equipment for gas-heated infrared dryers

                                The ventilation equipment of gas-heated infrared dryers is shown in
                                the flow sheet:


                                                                                            REGULATION DAMPERS
                                                                                            FOR MAKE-UP AIR AND
                                                                                            EXHAUST AIR

                                                     PREFILTER

                                                   FINEFILTER


                                 PRESSURE DIFFERENCE
                                 ALARM OF FILTER GUARD


                                                 PDA                                           CIRCULATION
                                                                                               AIR FAN


                                        COMBUSTION                                 TIC
                                        AIR FAN
                                                                                               TEMPERATURE
                                                         PIC                                   CONTROL


                                                                                   PIC
                                        PRESSURE                                               PRESSURE
                                        CONTROL                                                CONTROL



                                        REGULATION
                                        DAMPER

                                                        HSZ



                                Figure 4         Ventilation equipment for a gas-heated infrared dryer




PowerDry Classic air dryers                                                               4 Operating instructions
Q:AsiakasprojektitM00227KURKI700 PDF_ Operating and maintenance manual04 Operating
instructionsOperating_instructions.doc
Dong IL Paper Mfg., Co., Ltd.
                                                                                                  BM 1, (KURKI)
Air Systems/H. Suikki/PNä                        December 14, 2007                                             13


                                The function of the ventilation equipment of all gas-heated infrared
                                dryers is the same. The capacity of the infrared dryer is directly
                                proportional to the combustion air pressure. The pressure is
                                measured in the infrared dryer. The automation system has a control
                                circuit which regulates the correct pressure by means of a damper
                                located in the combustion air duct.

2.1.1 Combustion air

                                The combustion air system produces to the infrared dryer the air
                                needed for gas burning. The combustion air is taken from the fan
                                room, filtered and blown to the emitters.

                                The cleanness of the combustion air filters can be watched by
                                a differential pressure gauge which gives an alarm to the automation
                                system when the filter is dirty.

                                Limit values:
                                •    clean filter 45 Pa
                                •    filter to be replaced 250 Pa

                                The type of combustion air filters:
                                •    fine filter: Viledon AC50 EU5

2.1.2 Circulation air

                                The circulation air system intensifies heat transfer and discharge of
                                the evaporated water by circulating hot air between the web and the
                                emitter.

                                The make-up air of circulation air is taken from the fan room and the
                                exhaust air is blown to the existing heat recovery and outdoors.

                                The circulation air temperature is regulated automatically by means
                                of dampers located in the exhaust and make-up air ducts. If the
                                temperature exceeds the set value, the exhaust air and make-up air
                                dampers open. The dampers are regulated in parallel, or both of
                                them are always equally open.

                                The circulation air pressure is kept constant by the regulation of the
                                inlet vane control of the circulation air fan.




PowerDry Classic air dryers                                                               4 Operating instructions
Q:AsiakasprojektitM00227KURKI700 PDF_ Operating and maintenance manual04 Operating
instructionsOperating_instructions.doc
Dong IL Paper Mfg., Co., Ltd.
                                                                                                  BM 1, (KURKI)
Air Systems/H. Suikki/PNä                        December 14, 2007                                             14

2.1.3 Interlockings

                                The pressure control of the combustion air must always be in AUTO
                                mode and the operator gives the desired set value of pressure. The
                                minimum position of the regulator output is 40%.

                                The temperature control of the circulation air must always be in
                                AUTO mode and the operator cannot set it to MAN mode. The
                                minimum position of the controller output is 25%.

                                The pressure control of the circulation air must always be in AUTO
                                mode and the operator cannot set it to MAN mode. The minimum
                                position of the controller output is 50%.

                                During the start-up the supplier of gas-heated infrared dryers
                                regulates the actuator operating ranges of the ventilation equipment
                                of the gas-heated infrared dryers by means of mechanical limit
                                screws. This limited operating range is set as limit values of the
                                output of the process control system in question.

                                The gas-heated infrared dryers are controlled according to the
                                instructions by the supplier of infrared dryers.




PowerDry Classic air dryers                                                               4 Operating instructions
Q:AsiakasprojektitM00227KURKI700 PDF_ Operating and maintenance manual04 Operating
instructionsOperating_instructions.doc

Contenu connexe

En vedette

Marketer do Século XXI - APPM
Marketer do Século XXI - APPM  Marketer do Século XXI - APPM
Marketer do Século XXI - APPM Rui Ventura
 
Solving Algebraic Expressions with properties of numbers and
Solving Algebraic Expressions with properties of numbers andSolving Algebraic Expressions with properties of numbers and
Solving Algebraic Expressions with properties of numbers andFidelfo Moral
 
Skf half year-2010_sv
Skf half year-2010_svSkf half year-2010_sv
Skf half year-2010_svSKF
 
The role of research libraries in a European e-science environment
The role of research libraries in a European e-science environmentThe role of research libraries in a European e-science environment
The role of research libraries in a European e-science environmentWouter Schallier
 
Ice Strategic Overview 2011 V1
Ice Strategic Overview 2011   V1Ice Strategic Overview 2011   V1
Ice Strategic Overview 2011 V1jrowley9999
 
Bioremediation of Chlorobenzenes
Bioremediation of ChlorobenzenesBioremediation of Chlorobenzenes
Bioremediation of ChlorobenzenesTurlough Guerin
 
Care safety quiz
Care safety quizCare safety quiz
Care safety quizadisg
 
Keep Up with the Demands of IT Security on a Nonprofit Budget
Keep Up with the Demands of IT Security on a Nonprofit BudgetKeep Up with the Demands of IT Security on a Nonprofit Budget
Keep Up with the Demands of IT Security on a Nonprofit BudgetBVU
 
Ppp Canliner Presentation 6 09
Ppp Canliner Presentation 6 09Ppp Canliner Presentation 6 09
Ppp Canliner Presentation 6 09Theodore Lundy
 
Braziiilll
BraziiilllBraziiilll
Braziiillldltony
 
The human circulatory system
The human circulatory systemThe human circulatory system
The human circulatory systemadisg
 

En vedette (18)

Marketer do Século XXI - APPM
Marketer do Século XXI - APPM  Marketer do Século XXI - APPM
Marketer do Século XXI - APPM
 
Solving Algebraic Expressions with properties of numbers and
Solving Algebraic Expressions with properties of numbers andSolving Algebraic Expressions with properties of numbers and
Solving Algebraic Expressions with properties of numbers and
 
Skf half year-2010_sv
Skf half year-2010_svSkf half year-2010_sv
Skf half year-2010_sv
 
The role of research libraries in a European e-science environment
The role of research libraries in a European e-science environmentThe role of research libraries in a European e-science environment
The role of research libraries in a European e-science environment
 
giftee@NCC2010
giftee@NCC2010giftee@NCC2010
giftee@NCC2010
 
Arte en adornos
Arte en adornosArte en adornos
Arte en adornos
 
Ice Strategic Overview 2011 V1
Ice Strategic Overview 2011   V1Ice Strategic Overview 2011   V1
Ice Strategic Overview 2011 V1
 
Bioremediation of Chlorobenzenes
Bioremediation of ChlorobenzenesBioremediation of Chlorobenzenes
Bioremediation of Chlorobenzenes
 
Weight Loss
Weight LossWeight Loss
Weight Loss
 
Care safety quiz
Care safety quizCare safety quiz
Care safety quiz
 
Keep Up with the Demands of IT Security on a Nonprofit Budget
Keep Up with the Demands of IT Security on a Nonprofit BudgetKeep Up with the Demands of IT Security on a Nonprofit Budget
Keep Up with the Demands of IT Security on a Nonprofit Budget
 
D’Well Research
D’Well ResearchD’Well Research
D’Well Research
 
Ppp Canliner Presentation 6 09
Ppp Canliner Presentation 6 09Ppp Canliner Presentation 6 09
Ppp Canliner Presentation 6 09
 
Braziiilll
BraziiilllBraziiilll
Braziiilll
 
Symmetry
SymmetrySymmetry
Symmetry
 
Cypress top talk
Cypress top talkCypress top talk
Cypress top talk
 
Chris Carsten David
Chris Carsten DavidChris Carsten David
Chris Carsten David
 
The human circulatory system
The human circulatory systemThe human circulatory system
The human circulatory system
 

Similaire à Operating Instructions

DESIGN & DEVELOPMENT OF FILTERLESS AIR PURIFIER AND HUMIDIFIER
DESIGN & DEVELOPMENT OF FILTERLESS AIR PURIFIER AND HUMIDIFIERDESIGN & DEVELOPMENT OF FILTERLESS AIR PURIFIER AND HUMIDIFIER
DESIGN & DEVELOPMENT OF FILTERLESS AIR PURIFIER AND HUMIDIFIERIRJET Journal
 
Review of Design of Air Conditioning System for Commercial and Domestic Appli...
Review of Design of Air Conditioning System for Commercial and Domestic Appli...Review of Design of Air Conditioning System for Commercial and Domestic Appli...
Review of Design of Air Conditioning System for Commercial and Domestic Appli...IRJET Journal
 
Three axis pneumatic modern trailer
Three axis pneumatic modern trailerThree axis pneumatic modern trailer
Three axis pneumatic modern trailer1apr1991
 
Aircraft anti icing & de-icing sytems project report
Aircraft anti icing & de-icing sytems project reportAircraft anti icing & de-icing sytems project report
Aircraft anti icing & de-icing sytems project report△ Eranga Jr. A.B.W
 
Behpmx2000 man
Behpmx2000 manBehpmx2000 man
Behpmx2000 mancesarlca1
 
design and fixture in horn assembly
design and fixture in horn assemblydesign and fixture in horn assembly
design and fixture in horn assemblyJayavignesh Jt
 
2 cuft-contractor
2 cuft-contractor2 cuft-contractor
2 cuft-contractorJane Smith
 
ventilation of many patients
ventilation of many patients ventilation of many patients
ventilation of many patients ALIRADI8
 
Modeling & Analysis of Centrifugal Blower using Composite Material
Modeling & Analysis of Centrifugal Blower using Composite MaterialModeling & Analysis of Centrifugal Blower using Composite Material
Modeling & Analysis of Centrifugal Blower using Composite MaterialIOSR Journals
 
IRJET- A Proposed Design of Semi Automatic Cleaning System for High Power...
IRJET-  	  A Proposed Design of Semi Automatic Cleaning System for High Power...IRJET-  	  A Proposed Design of Semi Automatic Cleaning System for High Power...
IRJET- A Proposed Design of Semi Automatic Cleaning System for High Power...IRJET Journal
 
HIGHWAY DIVIDER BASED AIR FILTRATION SYSTEM POWERED BY VERTICALAXIS WIND TURB...
HIGHWAY DIVIDER BASED AIR FILTRATION SYSTEM POWERED BY VERTICALAXIS WIND TURB...HIGHWAY DIVIDER BASED AIR FILTRATION SYSTEM POWERED BY VERTICALAXIS WIND TURB...
HIGHWAY DIVIDER BASED AIR FILTRATION SYSTEM POWERED BY VERTICALAXIS WIND TURB...IRJET Journal
 
IRJET- Implementation and Automation of Air Blaster
IRJET- Implementation and Automation of Air BlasterIRJET- Implementation and Automation of Air Blaster
IRJET- Implementation and Automation of Air BlasterIRJET Journal
 
Desiccant Beads for Optimal Compressed Air System Performance
Desiccant Beads for Optimal Compressed Air System PerformanceDesiccant Beads for Optimal Compressed Air System Performance
Desiccant Beads for Optimal Compressed Air System PerformanceSorbead India
 
IRJET- Thermal Investigation of Solid Desiccant Wheel based Dehumidificat...
IRJET-  	  Thermal Investigation of Solid Desiccant Wheel based Dehumidificat...IRJET-  	  Thermal Investigation of Solid Desiccant Wheel based Dehumidificat...
IRJET- Thermal Investigation of Solid Desiccant Wheel based Dehumidificat...IRJET Journal
 

Similaire à Operating Instructions (20)

IA & SA Compressed Air system.docx
IA & SA Compressed Air system.docxIA & SA Compressed Air system.docx
IA & SA Compressed Air system.docx
 
Air compressor operation care
Air compressor operation careAir compressor operation care
Air compressor operation care
 
DESIGN & DEVELOPMENT OF FILTERLESS AIR PURIFIER AND HUMIDIFIER
DESIGN & DEVELOPMENT OF FILTERLESS AIR PURIFIER AND HUMIDIFIERDESIGN & DEVELOPMENT OF FILTERLESS AIR PURIFIER AND HUMIDIFIER
DESIGN & DEVELOPMENT OF FILTERLESS AIR PURIFIER AND HUMIDIFIER
 
Review of Design of Air Conditioning System for Commercial and Domestic Appli...
Review of Design of Air Conditioning System for Commercial and Domestic Appli...Review of Design of Air Conditioning System for Commercial and Domestic Appli...
Review of Design of Air Conditioning System for Commercial and Domestic Appli...
 
Three axis pneumatic modern trailer
Three axis pneumatic modern trailerThree axis pneumatic modern trailer
Three axis pneumatic modern trailer
 
Aircraft anti icing & de-icing sytems project report
Aircraft anti icing & de-icing sytems project reportAircraft anti icing & de-icing sytems project report
Aircraft anti icing & de-icing sytems project report
 
Behpmx2000 man
Behpmx2000 manBehpmx2000 man
Behpmx2000 man
 
design and fixture in horn assembly
design and fixture in horn assemblydesign and fixture in horn assembly
design and fixture in horn assembly
 
2 cuft-contractor
2 cuft-contractor2 cuft-contractor
2 cuft-contractor
 
ventilation of many patients
ventilation of many patients ventilation of many patients
ventilation of many patients
 
Modeling & Analysis of Centrifugal Blower using Composite Material
Modeling & Analysis of Centrifugal Blower using Composite MaterialModeling & Analysis of Centrifugal Blower using Composite Material
Modeling & Analysis of Centrifugal Blower using Composite Material
 
D1000
D1000D1000
D1000
 
30120140507005
3012014050700530120140507005
30120140507005
 
30120140507005
3012014050700530120140507005
30120140507005
 
IRJET- A Proposed Design of Semi Automatic Cleaning System for High Power...
IRJET-  	  A Proposed Design of Semi Automatic Cleaning System for High Power...IRJET-  	  A Proposed Design of Semi Automatic Cleaning System for High Power...
IRJET- A Proposed Design of Semi Automatic Cleaning System for High Power...
 
HIGHWAY DIVIDER BASED AIR FILTRATION SYSTEM POWERED BY VERTICALAXIS WIND TURB...
HIGHWAY DIVIDER BASED AIR FILTRATION SYSTEM POWERED BY VERTICALAXIS WIND TURB...HIGHWAY DIVIDER BASED AIR FILTRATION SYSTEM POWERED BY VERTICALAXIS WIND TURB...
HIGHWAY DIVIDER BASED AIR FILTRATION SYSTEM POWERED BY VERTICALAXIS WIND TURB...
 
Automation 4.0
Automation 4.0Automation 4.0
Automation 4.0
 
IRJET- Implementation and Automation of Air Blaster
IRJET- Implementation and Automation of Air BlasterIRJET- Implementation and Automation of Air Blaster
IRJET- Implementation and Automation of Air Blaster
 
Desiccant Beads for Optimal Compressed Air System Performance
Desiccant Beads for Optimal Compressed Air System PerformanceDesiccant Beads for Optimal Compressed Air System Performance
Desiccant Beads for Optimal Compressed Air System Performance
 
IRJET- Thermal Investigation of Solid Desiccant Wheel based Dehumidificat...
IRJET-  	  Thermal Investigation of Solid Desiccant Wheel based Dehumidificat...IRJET-  	  Thermal Investigation of Solid Desiccant Wheel based Dehumidificat...
IRJET- Thermal Investigation of Solid Desiccant Wheel based Dehumidificat...
 

Operating Instructions

  • 1. Dong IL Paper Mfg., Co., Ltd. BM 1, (KURKI) Air Systems/H. Suikki/PNä December 14, 2007 i 4 OPERATING INSTRUCTIONS 1 AIR DRYERS .......................................................................................................... 1 1.1 Air dryer for board grades .............................................................................. 1 1.1.1 The operation principle .................................................................... 1 1.1.2 Retraction and supporting devices .................................................. 2 1.1.3 Circulation air equipment ................................................................. 4 1.1.4 Gas burner ....................................................................................... 5 1.1.5 Burner output / combustion air regulation ........................................ 5 1.1.6 Burner control .................................................................................. 6 1.1.7 Operational conditions and interlockings for burner ........................ 6 1.1.8 Automatic purging in normal circulation condition ........................... 7 1.1.9 Operation during web break. Short circulation equipment ............... 8 1.1.10 Preheating ....................................................................................... 8 1.1.11 Exhaust air equipment ..................................................................... 9 1.1.12 Make-up air equipment .................................................................... 9 1.1.13 Alarms ............................................................................................. 9 1.1.14 Maintenance .................................................................................. 10 2 VENTILATION EQUIPMENT OF INFRARED DRYERS ....................................... 12 2.1 Ventilation equipment for gas-heated infrared dryers .................................. 12 2.1.1 Combustion air .............................................................................. 13 2.1.2 Circulation air ................................................................................. 13 2.1.3 Interlockings .................................................................................. 14 PowerDry Classic air dryers 4 Operating instructions Q:AsiakasprojektitM00227KURKI700 PDF_ Operating and maintenance manual04 Operating instructionsOperating_instructions.doc
  • 2. Dong IL Paper Mfg., Co., Ltd. BM 1, (KURKI) Air Systems/H. Suikki/PNä December 14, 2007 1 1 AIR DRYERS 1.1 Air dryer for board grades 1.1.1 The operation principle The hot circulation air is fed to the nozzles through the ductwork in the air dryer box. The nozzles are near the paper web. Hot air is blown towards the web through slots which are crosswise in view of the paper web. The air dryer boxes consists of boxes, under which the paper web is going and the retraction and supporting device for opening the boxes. Hot blowing air to the air dryer Humid air back to circulation air ducts Air distribution ducts Blowing nozzles Figure 1 Air dryer box The air dryer nozzles are of Impingement type. PowerDry Classic air dryers 4 Operating instructions Q:AsiakasprojektitM00227KURKI700 PDF_ Operating and maintenance manual04 Operating instructionsOperating_instructions.doc
  • 3. Dong IL Paper Mfg., Co., Ltd. BM 1, (KURKI) Air Systems/H. Suikki/PNä December 14, 2007 2 Figure 2 Impingement nozzle This cooled and humid air is extracted between the blowing nozzles into the air dryer box where it is led by ducts outside the air dryer and into the circulation air ductwork. There are perforated plates between the blowing nozzles to prevent bits of paper from going into the circulation air. 1.1.2 Retraction and supporting devices The nozzle surfaces of the air dryer are very close to the paper web when operating. The air dryer boxes can be opened for tail threading, cleaning and maintenance. The air dryers are equipped with pneumatic hoisting cylinders which can move the air dryer away from the web. For cleaning of the nozzle area the tending side edge of the air dryer can be hoisted 200 mm. The air dryers open automatically after the web break. In the automatic system the air dryer can be opened and closed. Pre-alarm with electric bell will be given before retraction. PowerDry Classic air dryers 4 Operating instructions Q:AsiakasprojektitM00227KURKI700 PDF_ Operating and maintenance manual04 Operating instructionsOperating_instructions.doc
  • 4. Dong IL Paper Mfg., Co., Ltd. BM 1, (KURKI) Air Systems/H. Suikki/PNä December 14, 2007 3 Each air dryer has sensors which inform the automation system of the close position of the air dryer. The supporting devices are equipped with manual mechanical safety locks by which the air dryers can be locked in the open position. CLOSING THE AIR DRYERS CAN BE PREVENTED BY A MANUAL MECHANICAL SAFETY LOCKING DEVICE. SAFETY LOCKING MUST ALWAYS BE USED IF ONE ENTERS BETWEEN THE OPEN AIR DRYER. Cylinder Air Dryer Locked Open Figure 3 Manual mechanical safety locks PowerDry Classic air dryers 4 Operating instructions Q:AsiakasprojektitM00227KURKI700 PDF_ Operating and maintenance manual04 Operating instructionsOperating_instructions.doc
  • 5. Dong IL Paper Mfg., Co., Ltd. BM 1, (KURKI) Air Systems/H. Suikki/PNä December 14, 2007 4 1.1.3 Circulation air equipment The circulation air is taken from the return air (humid air) duct of the dryer and led to the circulation air fan. By the fan the circulation air is blown through the burner to the air dryer. Circulation air ductwork The circulation air duct is connected by exhaust and make-up air equipment which discharge the humid circulation air and bring in drier air. The supply and return sides of the circulation air duct are connected by a by-pass duct before the air dryer. In the by-pass duct and in the circulation air duct on the supply and return sides there are dampers equipped with an actuator. These dampers prevent the circulation air from flowing into the air dryer during a web break. There is a more detailed function description in Section "Operation during web break. Short circulation equipment". Circulation air fan The circulation air fan can be started and stopped in manual mode, if the combustion air fan is running. If the fan is in AUTO mode the fan can be started by using group start function, in that case the fan starts after certain delay when exhaust fan and combustion air fan are running. The blowing velocity in the air dryer nozzle affects the air dryer evaporation efficiency. The circulation fan has an inlet vane control damper. Its set value can be changed to change the blowing velocity. Inlet vane control damper The inlet vane control damper is closed when the circulation air fan stops. The automation system also opens the inlet vane control damper with a short delay to the set value after the start. PowerDry Classic air dryers 4 Operating instructions Q:AsiakasprojektitM00227KURKI700 PDF_ Operating and maintenance manual04 Operating instructionsOperating_instructions.doc
  • 6. Dong IL Paper Mfg., Co., Ltd. BM 1, (KURKI) Air Systems/H. Suikki/PNä December 14, 2007 5 1.1.4 Gas burner The gas burner is installed near the fan in the circulation air ductwork. It is a duct type burner where the expanded part of duct is equipped with a burner head composed of modules, a lighter, flame control equipment and a combustion air duct. Gas is brought to the burner through a special safety valve group whose safety, ignition and flame control functions are automatically operated by the control logic of the burner. Gas needs enough oxygen for complete combustion. The burner is equipped with a combustion air fan which takes air from the fan area and blows it to the burner. 1.1.5 Burner output / combustion air regulation The temperature of the air blown in the air dryer affects the evaporation efficiency of the air dryer. The burner output is changed by an actuator which regulates gas amount. The circulation air temperature of the air dryer is regulated by changing the burner output by gas control valve. Burner needs constant combustion air pressure and there is pressure control loop in automation system. Setpoint for pressure is fixed and operator can´t change it. Short circulation When the short air circuit is in use (web break, service) the control circuit of the circulation air temperature gets it’s measurement value from the temperature sensor after burner in the circulation air ductwork. The control system force the setpoint of air temperature to 100 °C during the short circuit. PowerDry Classic air dryers 4 Operating instructions Q:AsiakasprojektitM00227KURKI700 PDF_ Operating and maintenance manual04 Operating instructionsOperating_instructions.doc
  • 7. Dong IL Paper Mfg., Co., Ltd. BM 1, (KURKI) Air Systems/H. Suikki/PNä December 14, 2007 6 Normal operation circulation During normal operation and pre-heating period when the air dryer is closed the control circuit of the circulation air temperature gets it’s measurement value from the temperature sensor in air dryer. The temperature sensor in the circulation air ductwork serves as a temperature limit sensor. The maximum air temperature is 350 °C. The automation system measures the circulation supply air temperature for the normal operation and the temperature can be read in the display of the automation system. 1.1.6 Burner control The burner can be started and stopped either locally in the burner control box or alternatively in the automation system. The choice of the burner control, local / remote, is made in the burner control panel. Failures can also be reset either locally or in the automation system. There are signal lights for different failures in the burner control panel and all the failure information is given as alarms to the automation system. 1.1.7 Operational conditions and interlockings for burner 1 Emergency stop closes the gas safety locking valves and thus stops the burners. 2 The burner is ready to start if: − the exhaust air pressure is sufficient − the combustion air pressure is sufficient − the circulation air pressure is sufficient − (i.e. the fans are really running) − the temperature after the burner is under the pre-set maximum limit − the gas pressure is over the pre-set minimum limit − the gas pressure is under the pre-set maximum limit − the pre-purging sequence is proceeding without any interruption PowerDry Classic air dryers 4 Operating instructions Q:AsiakasprojektitM00227KURKI700 PDF_ Operating and maintenance manual04 Operating instructionsOperating_instructions.doc
  • 8. Dong IL Paper Mfg., Co., Ltd. BM 1, (KURKI) Air Systems/H. Suikki/PNä December 14, 2007 7 3 The burner starts (ignites) if: − the pre-purging sequence has been completed − the gas control valve is in min. position (low fire position) − the flame scanner is working − the selection switch in local burner panel is in local position or, in case the selection switch is in remote position, DCS program control “burner ready to start” 4 The burner starts automatically after "burner ready to start" mode has been achieved (pre-purging completed). 5 The burner is working (burns) if: − the flame scanner continuously recognizes a flame − the "pre-purging completed" - information is continuously valid − the burner control internal failure checkings are not indicating malfunctions If any of the operating conditions mentioned above is not at hand, the running burner is shut off or the ignition sequence is interrupted and the signal lamp in the control panel of the burner shows the actual failure. When the burner shuts off the gas valve automatically moves into the minimum position. In case of web break the burner control valves move to low fire position. When the burner has ignited and burns with minimum flame (low fire position), a signal lamp is lit and the burner effect can be adjusted, by regulating the main gas valve, to the desired level. 1.1.8 Automatic purging in normal circulation condition Before the burners can be ignited locally or remote, a so called pre- purging has to be carried out, by which any possible gas in the circulation air ductwork is exhausted. The pre-purging sequence takes ab. 60 seconds. The burner must continuously get the "pre- purging done" signal in order to burn. PowerDry Classic air dryers 4 Operating instructions Q:AsiakasprojektitM00227KURKI700 PDF_ Operating and maintenance manual04 Operating instructionsOperating_instructions.doc
  • 9. Dong IL Paper Mfg., Co., Ltd. BM 1, (KURKI) Air Systems/H. Suikki/PNä December 14, 2007 8 The one-minute pre-purging for normal circulation starts automatically when the exhaust air, the circulation air and combustion air fans are running. During the pre-purging the shut-off dampers opens and by-pass dampers closes automatically (so called long circulation), the exhaust air damper opens 100% and the circulation air damper opens 100 %. If these conditions are fulfilled during the pre-purging sequence, the condition "pre-purging done" is valid. The "Pre-purging done" condition has to be valid in order to be able to ignite the burners and to run them. The "Pre-purging done" condition disappears if the combustion, the exhaust, or circulation air fan stops. A new pre-purging of the system must then be carried out by starting the fan which has been stopped. 1.1.9 Operation during web break. Short circulation equipment The starting routines of the burner take several minutes due to the control and purging operations connected with the gas burner. In order to avoid unnecessary delays, it is practical to keep the gas burner and the air circulation running during short breaks. Web break opens the air dryers and the system goes to the short circulation. During the tail threading the air flows in short circulation circuit (through the by-pass duct to the inlet side of the circulation air fan), preventing it from blowing into the air dryer. 1.1.10 Preheating After a longer production stop the air dryer boxes have to be warmed up before tail threading. Preheating is operated from the air dryer display. The operator gives the temperature set value and preheating temperature set value from the display. Air dryer ready for coating information is displayed in the air dryer display and it is one condition of station ready for coating which is indicated with signal lamp in the control box. PowerDry Classic air dryers 4 Operating instructions Q:AsiakasprojektitM00227KURKI700 PDF_ Operating and maintenance manual04 Operating instructionsOperating_instructions.doc
  • 10. Dong IL Paper Mfg., Co., Ltd. BM 1, (KURKI) Air Systems/H. Suikki/PNä December 14, 2007 9 1.1.11 Exhaust air equipment When returning from the air dryer, the circulation air has cooled and the water evaporated from the web inside the air dryer has mixed with the air. To ensure a stable water content in the circulation air, the water picked up by evaporation must be removed before the air is blown back into the air dryer. Circulation air is "dried" by exhausting a certain amount of humid return air, removing the water mixed with it. There is one common exhaust air fan at coating station. The exhaust air is taken from the circulation air duct and led directly outdoors. The exhaust air amount is regulated with the damper of the exhaust air duct. The leakage air temperature corrects the air amount. If the fans are started with group start, the exhaust air fan will start first of all fans.The exhaust air fans can be started and stopped in manual mode without any interlockings. 1.1.12 Make-up air equipment The exhaust air is replaced by drier air. The make-up air is sucked directly from the mezzanine floor into the circulation air system. The duct is equipped with a local manual control damper. 1.1.13 Alarms • Circulation air fan − Circulation air fan MCC failure • Circulation air temperature control − air dryer temperature too high • Circulation air temperature before fan/burner − temperature too high • Combustion air fan − Combustion air fan MCC failure • Exhaust air fan − Exhaust air fan MCC failure PowerDry Classic air dryers 4 Operating instructions Q:AsiakasprojektitM00227KURKI700 PDF_ Operating and maintenance manual04 Operating instructionsOperating_instructions.doc
  • 11. Dong IL Paper Mfg., Co., Ltd. BM 1, (KURKI) Air Systems/H. Suikki/PNä December 14, 2007 10 • Burner control − high temperature − low gas pressure − high gas pressure − low process air pressure − low exhaust air pressure − low combustion air pressure − low fire micro switch open − flame off − emergency switch − burner in operation − burner in local control • Air dryer retraction − time alarm if the top box does not close or open in valid time − pre-alarm with electric bell will be given before retraction 1.1.14 Maintenance Cleaning To ensure fire safety and faultless operation, the air dryer and the blowing nozzles must be kept clean both outside and inside. The outside of air dryer is washed clean. The inside is blown by pressurized air. The blowing nozzles and the suction holes must be cleaned as soon as they have got dirty. They are cleaned by a brush or a wet sponge. It is not recommended to clean them by a water jet because hot metal parts may be damaged. If the nozzles are blocked, problems can occur in the coating. Therefore the nozzles must be cleaned at every washing shutdown. The nozzle surfaces must not be scratched. PowerDry Classic air dryers 4 Operating instructions Q:AsiakasprojektitM00227KURKI700 PDF_ Operating and maintenance manual04 Operating instructionsOperating_instructions.doc
  • 12. Dong IL Paper Mfg., Co., Ltd. BM 1, (KURKI) Air Systems/H. Suikki/PNä December 14, 2007 11 Control and regulationof an air dryer The following things must be checked at least four times a year: • The air dryers moven open/shut without obstacles both when cold and when operating. • The air dryer is in the closed position against stoppers so that the clearance in the drawing is in the attaching parts of pneumatic cylinders. • Heat expansion of the air dryer has no obstacles across the web on the tending side. • The safety locking mechanism for the open position of the air dryer works well. • The nozzle surfaces are clean. PowerDry Classic air dryers 4 Operating instructions Q:AsiakasprojektitM00227KURKI700 PDF_ Operating and maintenance manual04 Operating instructionsOperating_instructions.doc
  • 13. Dong IL Paper Mfg., Co., Ltd. BM 1, (KURKI) Air Systems/H. Suikki/PNä December 14, 2007 12 2 VENTILATION EQUIPMENT OF INFRARED DRYERS Infrared dryers are used for heating a certain material aglow. The glowing surface placed near the paper web transfers its heat energy by emission to the water in the paper. The temperature of the moist paper web can be raised quickly by means of the big energy transfer of the infrared dryer. 2.1 Ventilation equipment for gas-heated infrared dryers The ventilation equipment of gas-heated infrared dryers is shown in the flow sheet: REGULATION DAMPERS FOR MAKE-UP AIR AND EXHAUST AIR PREFILTER FINEFILTER PRESSURE DIFFERENCE ALARM OF FILTER GUARD PDA CIRCULATION AIR FAN COMBUSTION TIC AIR FAN TEMPERATURE PIC CONTROL PIC PRESSURE PRESSURE CONTROL CONTROL REGULATION DAMPER HSZ Figure 4 Ventilation equipment for a gas-heated infrared dryer PowerDry Classic air dryers 4 Operating instructions Q:AsiakasprojektitM00227KURKI700 PDF_ Operating and maintenance manual04 Operating instructionsOperating_instructions.doc
  • 14. Dong IL Paper Mfg., Co., Ltd. BM 1, (KURKI) Air Systems/H. Suikki/PNä December 14, 2007 13 The function of the ventilation equipment of all gas-heated infrared dryers is the same. The capacity of the infrared dryer is directly proportional to the combustion air pressure. The pressure is measured in the infrared dryer. The automation system has a control circuit which regulates the correct pressure by means of a damper located in the combustion air duct. 2.1.1 Combustion air The combustion air system produces to the infrared dryer the air needed for gas burning. The combustion air is taken from the fan room, filtered and blown to the emitters. The cleanness of the combustion air filters can be watched by a differential pressure gauge which gives an alarm to the automation system when the filter is dirty. Limit values: • clean filter 45 Pa • filter to be replaced 250 Pa The type of combustion air filters: • fine filter: Viledon AC50 EU5 2.1.2 Circulation air The circulation air system intensifies heat transfer and discharge of the evaporated water by circulating hot air between the web and the emitter. The make-up air of circulation air is taken from the fan room and the exhaust air is blown to the existing heat recovery and outdoors. The circulation air temperature is regulated automatically by means of dampers located in the exhaust and make-up air ducts. If the temperature exceeds the set value, the exhaust air and make-up air dampers open. The dampers are regulated in parallel, or both of them are always equally open. The circulation air pressure is kept constant by the regulation of the inlet vane control of the circulation air fan. PowerDry Classic air dryers 4 Operating instructions Q:AsiakasprojektitM00227KURKI700 PDF_ Operating and maintenance manual04 Operating instructionsOperating_instructions.doc
  • 15. Dong IL Paper Mfg., Co., Ltd. BM 1, (KURKI) Air Systems/H. Suikki/PNä December 14, 2007 14 2.1.3 Interlockings The pressure control of the combustion air must always be in AUTO mode and the operator gives the desired set value of pressure. The minimum position of the regulator output is 40%. The temperature control of the circulation air must always be in AUTO mode and the operator cannot set it to MAN mode. The minimum position of the controller output is 25%. The pressure control of the circulation air must always be in AUTO mode and the operator cannot set it to MAN mode. The minimum position of the controller output is 50%. During the start-up the supplier of gas-heated infrared dryers regulates the actuator operating ranges of the ventilation equipment of the gas-heated infrared dryers by means of mechanical limit screws. This limited operating range is set as limit values of the output of the process control system in question. The gas-heated infrared dryers are controlled according to the instructions by the supplier of infrared dryers. PowerDry Classic air dryers 4 Operating instructions Q:AsiakasprojektitM00227KURKI700 PDF_ Operating and maintenance manual04 Operating instructionsOperating_instructions.doc