ACEEE Int. J. on Electrical and Power Engineering , Vol. 4, No. 3, November 2013

PV Hybrid System with DSTATCOM for Residential
Applications
Ch.Venkateswra rao1, S.S.Tulasiram2, B.Brahmaiah3
1

PHD scholar, JNTUK, Kakinada. E-mail: chvr_4581@yahoo.co.in .
2
Professor, JNTUH, Hyderabad,
3
Principal, GEC ,Guntur

Abstract- Now a days PV based energy systems are playing a
vital role among all the renewable energy sourcesin our day
to day life.Proper control should be required to meet the exact
load conditions such that it should satisfy the non-linear
nature of both the solar irradiance and load. In this paper, a
battery is also incorporated along with the PV system to meet
the necessary drop due to change in weather conditions. Here,
a proper control is achieved by using DSTATCOM to
compensate the reactive power. This paper proposes an
advanced technique of PWM to generate the gating pulses
and applied to a Cascaded H-Bridge multilevel inverter to
improve the voltage quality. Here, the entire system is designed
to meet the load of Mogulthur (W.G.Dt. Andhra Pradesh).
Simulation results are presented through Matlab/Simulink
by taking different cases into consideration.
Index Terms:- PV system, Stand alone system, DSTATCOM,
Power quality.

I. INTRODUCTION
Today PV based power generation systems are becoming
more and more popular, with the increase of energy demand
and the concern of environmental pollution around the world.
One of the inherent advantages of PV electricity generation
is the absence of any mechanical parts. Professionally installed PV arrays are characterized by a long service lifetime,
exceeding 20 years, high reliability, and low maintenance requirements, which are highly desirable for remote area power
supplies. In sunny locations, PV generators compare
favourably with wind generators, despite the higher investment cost for PV modules per peak Watt. Wind generators
require regular maintenance and are susceptible to damage
in strong winds [2]. However, PV power fluctuates depending on the weather conditions, season, and geographic location, and may cause problems like voltage fluctuation and
large frequency deviation in e
lectric power system
operation [2]. Usually, an energy storage system (i.e., battery) is used to smooth the PV output power fluctuations
and then the smoothed power is supplied to the utility
[1].Power vs voltage characteristics of PV shows that PV can
generate maximum power at particular voltage called as V mpp
at corresponding level of irradiance. For best utilization, the
PV cells must be operated at their maximum power point.
According to perturb and observe (P&O) algorithm, maximum power point tracking (MPPT) is achieved by adjusting
the terminal voltage of PV panels to V mpp .
1
© 2013 ACEEE
DOI: 01.IJEPE.4.3. 1337

To supply a qualitative power is the main challenge in a
stand-alone system. Voltage variations, flickers and harmonic
generation are the major power quality (PQ) problems that
occur in solar energy conversion system .Those power quality
problems may not be tolerated by the customers and hence
require mitigation techniques[5].One of the most promising
applications of renewable energy technology is the
installation of hybrid energy systems in remote areas, where
the cost of grid extension is prohibitive and the price for fuel
drastically increases with the remoteness of the location.
Renewable energy sources, such as photovoltaic (PV), wind
energy, or small-scale hydro, provide a realistic alternative to
engine-driven generators for electricity generation in remote
areas. [3].
This paper concentrates on the control and application
of PV-battery hybrid energy systems, which account for the
majority of systems installed today. A system to provide
uninterrupted power which integrates PV, battery and inverter
has been considered. In general four different system
configurations are widely developed in stand-alone PV power
applications: the centralized inverter system, the string inverter
system, the multi-string inverter system and the moduleintegrated inverter system. [4]. Mostly centralized inverter
system can be employed for small-scale distributed generation
(DG) systems, such as residential power applications.
Residential loads are mostly single phase loads; Therefore,
in this paper single phase cascaded H-bridge five level inverter
is used in the conversion of photovoltaic voltage (D.C) to
our Domestic voltage (A.C). Here an advanced technique of
unipolar phase disposition pulse width modulation is
provided to nullify the switching losses and to improve the
output voltage quality.
II. SYSTEM DESCRIPTION
Photovoltaic inverters become more and
more widespread within both private and commercial circles.
The isolated power utility used in this paper is shown in Fig.
1. This is actually a parallel PV-battery hybrid power system
consisted of a PV generator, battery, a bidirectional converter
(MPPT for V), multilevel inverter, DSTATCOM and ac load.
In addition, it is assumed that the isolated power utility is not
connected to any large power utility and it is always independently operated as a stand-alone system. The battery
supplies the load demand when no PV power/few PV power
is available.
Full Paper
ACEEE Int. J. on Electrical and Power Engineering , Vol. 4, No. 3, November 2013

Fig. 1: PV based hybrid power generation system

Fig 1(a) Block Diagram of H-bridge inverter

Fig. 2: Load profile of Mogultur village, Andhrapradesh, India

Cascaded Multilevel H-Bridge Inverter:
As seen in the structure of cascaded H-Bridge Invertors
in fig.1(a), each H-bridge inverter needs a separate or isolated
DC source. This requirement makes the cascaded inverter a
perfect fit for utility interface of renewable energy sources
such as photo voltaic or fuel cells where isolated dc sources
naturally exist. Since the cascaded inverter eliminates custom
designed transformers, a tremendous cost reduction can be
expected.
AC load considered in this paper is taken from Mogultur
village, Narspurmandal, West Godavari district,
Andhrapradesh state, India. The profile of load for 24 hours
is shown in Fig. 2. According to this load, maximum 61.28kW
power supply is required to drive the load. However, solar
irradiance will not meet 1000W/m2 in Andhrapradesh. Hence,
for safe and reliable operation, selection of solar power should
be more than 61.28kW.
The required rms of single phase is 230V ac50 Hz frequency. To avoid over modulation index, during reactive
power and considering loses at LC filter minimum 300V dc is
required to maintain 230V rms at load bus. Hence, in this
paper, minimum dc link is considered as 300V. For best utilization, the PV cells must be operated at their maximum power
point. To extract the maximum power from PV, PV system
should operate at voltage corresponding to maximum power,
this can achieve by power electronics converter which can
regulate the dc link voltage. Considered minimum solar irradiance is 200W/m2. So that selected PV system should operate 300V at 200W/m2 irradiance. The PV module is the result
2
© 2013 ACEEE
DOI: 01.IJEPE.4.3.1337

of associating a group of PV cells connected in series and
parallel. The TSM305 PV model is available in the market, and
it is considered in this paper to implement in Matlab/simulink.
In this paper a PV array consist of 9 PV modules. Each module having open circuit voltage as 43.20V, short circuit current is 9.49A, voltage at maximum power (Vmpp) is 36V and
current at maximum power is 8.47. The PV cell is shown in Fig.
3(a) and power vs voltage curves of one PV array are shown
in Fig. 3(b) with different level of solar irradiance. Fig. 3(b)
shows that PV can generate maximum power at particular
voltage at corresponding level of irradiance. According to
perturb and observe (P&O) algorithm, MPPT is achieved by
adjusting the terminal voltage of PV panels to Vmpp. In this
paper PV panel is directly connected to the dc bus and P&O
algorithm for MPPT is incorporated using dc-dc converter
(connected between battery and dc-link). Therefore, dc-dc
converter not only controls the dc-link voltage but also acts
a MPPT and hence additional MPPT circuit for PV is not
required.
Since 9 modules are connected in series, Vmpp of PV arrays will vary from 300 to 324V according to solar irradiance
(G) varies from 200 to 1000W/m2. Vmpp which is output of
P&O algorithm will then act as reference dc-link voltage to
dc-dc converter control. The maximum power rating of each
array is 2745Wand hence by using 29 arrays in parallel, therefore maximum solar power generation is nearly 80 kW. This
can maintain the load demand. In case of PV power is more
than the load demand, the surplus power will dump into the
battery. Hence the selection of battery is depends on
Full Paper
ACEEE Int. J. on Electrical and Power Engineering , Vol. 4, No. 3, November 2013
maximum surplus power from PV. However, the minimum load
is 17.25kW. Therefore maximum surplus power will be
62.75kW. Considering reliability and safe operation of the
system considered 65kW battery which is available in the
market.

boost converter, the battery voltage can be kept lower as
compared to reference dc-link voltage and hence less number of batteries need to be connected in series. In the proposed system battery voltage is kept at about 180 V (i.e 15
batteries each 12V are connected in series). Hence in the
design of dc-dc converter control, limiter is connected after
generating Vmpp by P&O algorithm which limits the reference voltage of dc-link between 324 V to 300 V. The lower
limit of dc voltage (i.e 300V) corresponds to 200 W/m2 irradiance. Hence, for irradiance below 200 W/m2, P&O algorithm
acts as constant voltage MPPT algorithm. This is helpful to
operate the system during night time and under non sunny
days. Matlab based implementation of P&O algorithm is
shown in Fig. 3(c). In Fig. 3, inputs are voltage of PV panel
and current of PV system. Steep change is decided based on
change in power. The output of the system is Vmpp and it is
treated as input to controller of dc-dc converter, hence extra
converter to track maximum power from PV is not required.

Fig. 3: (a) single cell model; (b) P-V curve of one PV array

The battery is connected to the dc-link through a dc- dc
bidirectional buck-boost converter. Using bidirectional buck-

Fig. 3: (c) P&O algorithm

inverter control as shown in Fig. 4 (b). Modulation index
generated by PI controller is feed to PWM generator so that
required pulses are generated by PWM generator according
to reference voltage of AC bus (i.e., 230). As far as frequency
of output ac voltage is concerned, it can be maintained at
specified value by choosing the frequency of sinusoidal reference signal while generating the PWM pulses

III. CONTROL OF DC LINK AND AC BUS VOLTAGE
Due to variations in the solar irradiation and load; dc-link
voltage varies because of power mismatch between sources
and load. Hence, it is required to maintain dc-link voltage
constant irrespective of variations in solar irradiation and
load. Battery is used to maintain the power balance of the
system. In this paper, bidirectional buck-boost converter is
connected between dc-link and battery to maintain the charging and discharging process corresponding to changes in
load and generation power. Hence proper controller design
is required to control the dc-link. The controller of buckboost converter is shown in Fig. 4 (a), where two switches
are used to control the charging and discharging process.
Reference dc-link voltage which is generated from P&O algorithm is compared to dc-link voltage and error is fed to
proportional plus integral (PI) controller. The output of PI
controller gives the reference battery current. Pulses for two
switches (dc-dc converter) are generated with the help of
hysteresis current control loop by comparing reference and
actual currents of battery.
In order to obtain the required pulses an unipolar phase
disposition technique is developed and by using necessary
logic gates and the obtained pulses are shown below to
© 2013 ACEEE
DOI: 01.IJEPE.4.3. 1337

Fig. 4: (a) Bidirectional dc –dc converter control, (b) Inverter
control

3
Full Paper
ACEEE Int. J. on Electrical and Power Engineering , Vol. 4, No. 3, November 2013
Block diagram of PWM Generator

Figure 5 Logic applied to generate pulses

Here, in each H-bridge, 4 power devices are operated at 2
different frequencies i.e., 2 are commutated at low
frequency(i.e., fundamental) while other 2 are pulse width
modulated at high frequency causes problem of differential
switching losses among the switches. So proper logic is
implemented in order to give the firing pulses and is shown
in (fig.5) The gating pattern generated is shown (fig.9) So, to
eliminate this, a hybrid PWM controller is used to mix
a) Sequential signal
b) Low frequency PWM
c) High frequency phase disposition SPWM and to
generate appropriate pulses for cascaded inverter and the
appropriate
results are shown in fig 9(a) and 9(b)

Sg12 , Sg42 , Sg32 , Sg22
Generally home loads are consuming reactive power, but
PV-Battery cannot supply reactive power because of those
are DC sources. In this condition alternate support is required to either supply or compensate the required reactive
power by the load. This can achieve by using DSTATCOM
[6]. In this paper, DSTATCOM is connected after LC filter
and propose controller to compensate required reactive
power by load. The controller for DSTATCOM is shown in
Fig. 6. For the DSTATCOM controller, compared both reactive powers by load and DSTATCOM The error is given to PI
controller and it is generated required modulation index. Pulses
are generated with PWM generator by using modulation index generated by PI controller. Generated PWM signals will
go to DSTATCOM.

Fig.9(a) Gating pulses for first bridge

Sg11, Sg41 , Sg31 , Sg21
Fig. 6: DSTATCOM control

IV. RESULTS AND DISCUSSIONS
The results are carried out by Matlab/simulink and those
are discussed by following case studies.
Case A: Change in Solar Irradiance:
Considered solar irradiance reduced from 1000 to 650W/
m2 at t=4sec. as shown in Fig. 6 (a). For this change, P&O
algorithm will track voltage at maximum power (Vref) as shown
in Fig. 6(b). Corresponding maximum and power generated
by PV system is shown in Fig. 6(c). From Fig. 6(c), it shows
the dc to dc converter helps to track the maximum power from

Fig. 9(b)Gating pulses for second bridge

© 2013 ACEEE
DOI: 01.IJEPE.4.3.1337

4
Full Paper
ACEEE Int. J. on Electrical and Power Engineering , Vol. 4, No. 3, November 2013
PV system. Therefore proposed dc to dc convert not only
regulates the dc link voltage it also act as MPPT for PV
system. Hence, extra MPPT is not required for PV.

Fig. 6: (a) change in irradiance, (b) Vref generated by P&O, (c) PV
powers

Fig. 8: (a) rms voltage at AC bus, (b) Powers

Case B: Change in Load Power (Active power):
Now considered load changes from 32.78kW to 59.26kW
at t= 2sec. (corresponding 18th and 19th hour as shown in Fig.
2). Maximum load change is considered to show the response
of dc-link and AC rms voltage, however, practically solar
irradiance is almost zero during this time period. In this case,
we considered irradiance is at 650W/m2in simulation results.
During this change, dc link voltage is stable and it is depicted
in Fig. 7 (a). Corresponding rms voltage at AC bus and various
powers in the system is shown in Fig. 7(b) and (c) respectively.
From Fig. 7 (a) and (b) it is represents the system maintaining
good power quality.
Case C: Reactive Power Compensation:
In this case, considered irradiance at maximum level and
applied 20 kVAR along with 20kW power to the load at t=
3sec. before, t=3 sec. the active power consumed by load is
25kW. Therefore after t=3 sec, power factor will be 0.8 at load
bus. In this scenario, DSTATCOM compensate reactive power
required by the load so that no need to supply reactive power
by inverter which is connected to dc link. The corresponding
rms voltage and various powers included in system are shown
in Fig. 8(a) and (b) respectively.
From Fig 8(a), it is observe that, the output phase rms
voltage is almost immune to fluctuations. The rms value of
output ac voltage may not give the clear picture of voltage
waveform in the transient condition; hence instantaneous
current and voltage are presented in Fig. 9 (a) and (b)

Fig. 7: (a) dc link voltage, (b) rms voltage at AC bus, (c) Powers

© 2013 ACEEE
DOI: 01.IJEPE.4.3.1337

5
Full Paper
ACEEE Int. J. on Electrical and Power Engineering , Vol. 4, No. 3, November 2013
respectively. From Fig. 9 (b) at t=3sec. it is seen that there is
no significant rise in the voltage waveform during load transient. The total harmonic distortion (THD) in the output ac
voltage is about 5% in all the three phases. Hence it can be
established that with the help of PWM switching and a passive LC filter, a satisfactory quality of voltage can be supplied to the loads. The frequency at AC bus is shown in Fig.
10, From Fig. 10, there is no change in frequency with respect
to changes in load as well as irradiance.

V. CONCLUSION
PV-battery based hybrid power generation system for
residential application is presented in this paper. Voltage
quality is maintained with respect to changes in load and
solar irradiance. Proper controllers are designed and achieved
proper energy management between various sources and
load. Battery is connected through dc-dc bidirectional
convert to improve the power quality with respect to changes
in solar irradiance and load. P&O algorithm is incorporated
to controller of dc-dc bidirectional converter which is
connected between dc bus and battery. Hence, dc-dc converter
acts as MPPT converter for PV. Therefore, extra circuit is not
required to extract the maximum power from PV. DSTATCOM
is connected to AC bus to improve voltage quality as well as
reactive power compensation. Also a five level multilevel
inverter is designed with its advanced PWM technique in
order to improve the quality. From results one can observe
system maintained good power quality in all the possible
conditions.
REFERENCES
[1]

Fig. 10: Response of frequency

[2]

[3]

[4]

[5]
Fig.11: Instantaneous Voltage at AC bus

Fig.11 shows the output voltage wave forms of an cascaded
h-bridge five level inverter in which the pv voltage is converted
to ac voltage.

© 2013 ACEEE
DOI: 01.IJEPE.4.3.1337

[6]

6

M. Datta et al, “A Frequency-Control Approach by
Photovoltaic Generator in a PV–Diesel Hybrid Power System”,
IEEE Transactions on Energy Conversion, Vol. 26, No. 2,
June 2011.
C. V. Nayar et al, “A Grid-Interactive Photovoltaic
Uninterruptible Power Supply System Using Battery Storage
and a Back Up Diesel Generator”, IEEE Transactions on Energy
Conversion, Vol. 15, No. 3, Sept. 2000.
R. W. Wies, et al, “Simulink Model for Economic Analysis and
Environmental Impacts of a PV With Diesel-Battery System
for Remote Villages”, IEEE Transactions on Power Systems,
Vol. 20, No. 2, May 2005
T. Kerekes et al, “A New High-Efficiency Single-Phase
Transformer less PV Inverter Topology”, IEEE Transactions
on Industrial Electronics, Vol. 58, No. 1, Jan. 2011.
Bo Yang et al, “Design and Analysis of a Grid-Connected
Photovoltaic Power System” IEEE Transactions on Power
Electronics, Vol. 25, No. 4, April 2010.
M. K. Mishra et al, “Operation of a DSTATCOM in Voltage
Control Mode”, IEEE Transactions on Power Delivery, Vol.
18, No. 1, Jan. 2003.

Contenu connexe

Tendances

Development of Load Control Algorithm for PV Microgrid
Development of Load Control Algorithm for PV Microgrid Development of Load Control Algorithm for PV Microgrid
Development of Load Control Algorithm for PV Microgrid IJECEIAES
 
A single stage photo voltaic grid-connected inverter using spwm
A single stage photo voltaic grid-connected inverter using spwmA single stage photo voltaic grid-connected inverter using spwm
A single stage photo voltaic grid-connected inverter using spwmSHAIK AMANULLA
 
Drive Applications of Fuzzy Logic Controlled Interleaved Boost Converter for ...
Drive Applications of Fuzzy Logic Controlled Interleaved Boost Converter for ...Drive Applications of Fuzzy Logic Controlled Interleaved Boost Converter for ...
Drive Applications of Fuzzy Logic Controlled Interleaved Boost Converter for ...EECJOURNAL
 
Push-Pull Converter Fed Three-Phase Inverter for Residential and Motor Load
Push-Pull Converter Fed Three-Phase Inverter for Residential and Motor LoadPush-Pull Converter Fed Three-Phase Inverter for Residential and Motor Load
Push-Pull Converter Fed Three-Phase Inverter for Residential and Motor LoadIJPEDS-IAES
 
All ieee 2013
All ieee 2013All ieee 2013
All ieee 2013Ecwayt
 
All ieee 2013
All ieee 2013All ieee 2013
All ieee 2013Ecwayt
 
Design and Development of Power Electronic Controller for Grid-connected PV A...
Design and Development of Power Electronic Controller for Grid-connected PV A...Design and Development of Power Electronic Controller for Grid-connected PV A...
Design and Development of Power Electronic Controller for Grid-connected PV A...IJAPEJOURNAL
 
Power Quality Improvement with Multilevel Inverter Based IPQC for Microgrid
Power Quality Improvement with Multilevel Inverter Based IPQC for MicrogridPower Quality Improvement with Multilevel Inverter Based IPQC for Microgrid
Power Quality Improvement with Multilevel Inverter Based IPQC for MicrogridIJMTST Journal
 
Battery energy storage and power electronics based voltage and frequency cont...
Battery energy storage and power electronics based voltage and frequency cont...Battery energy storage and power electronics based voltage and frequency cont...
Battery energy storage and power electronics based voltage and frequency cont...IAEME Publication
 
IJSETR-VOL-2-ISSUE-7-1526-1530
IJSETR-VOL-2-ISSUE-7-1526-1530IJSETR-VOL-2-ISSUE-7-1526-1530
IJSETR-VOL-2-ISSUE-7-1526-1530Vijay Kannan
 
Research Inventy : International Journal of Engineering and Science
Research Inventy : International Journal of Engineering and ScienceResearch Inventy : International Journal of Engineering and Science
Research Inventy : International Journal of Engineering and Scienceinventy
 
Simulation of various DC-DC converters for photovoltaic system
Simulation of various DC-DC converters for photovoltaic systemSimulation of various DC-DC converters for photovoltaic system
Simulation of various DC-DC converters for photovoltaic systemIJECEIAES
 
A Novel Three Phase Multi-string Multilevel Inverter with High DC-DC Closed o...
A Novel Three Phase Multi-string Multilevel Inverter with High DC-DC Closed o...A Novel Three Phase Multi-string Multilevel Inverter with High DC-DC Closed o...
A Novel Three Phase Multi-string Multilevel Inverter with High DC-DC Closed o...rnvsubbarao koppineni
 

Tendances (15)

Fr3610401047
Fr3610401047Fr3610401047
Fr3610401047
 
Development of Load Control Algorithm for PV Microgrid
Development of Load Control Algorithm for PV Microgrid Development of Load Control Algorithm for PV Microgrid
Development of Load Control Algorithm for PV Microgrid
 
A single stage photo voltaic grid-connected inverter using spwm
A single stage photo voltaic grid-connected inverter using spwmA single stage photo voltaic grid-connected inverter using spwm
A single stage photo voltaic grid-connected inverter using spwm
 
L01052101108
L01052101108L01052101108
L01052101108
 
Drive Applications of Fuzzy Logic Controlled Interleaved Boost Converter for ...
Drive Applications of Fuzzy Logic Controlled Interleaved Boost Converter for ...Drive Applications of Fuzzy Logic Controlled Interleaved Boost Converter for ...
Drive Applications of Fuzzy Logic Controlled Interleaved Boost Converter for ...
 
Push-Pull Converter Fed Three-Phase Inverter for Residential and Motor Load
Push-Pull Converter Fed Three-Phase Inverter for Residential and Motor LoadPush-Pull Converter Fed Three-Phase Inverter for Residential and Motor Load
Push-Pull Converter Fed Three-Phase Inverter for Residential and Motor Load
 
All ieee 2013
All ieee 2013All ieee 2013
All ieee 2013
 
All ieee 2013
All ieee 2013All ieee 2013
All ieee 2013
 
Design and Development of Power Electronic Controller for Grid-connected PV A...
Design and Development of Power Electronic Controller for Grid-connected PV A...Design and Development of Power Electronic Controller for Grid-connected PV A...
Design and Development of Power Electronic Controller for Grid-connected PV A...
 
Power Quality Improvement with Multilevel Inverter Based IPQC for Microgrid
Power Quality Improvement with Multilevel Inverter Based IPQC for MicrogridPower Quality Improvement with Multilevel Inverter Based IPQC for Microgrid
Power Quality Improvement with Multilevel Inverter Based IPQC for Microgrid
 
Battery energy storage and power electronics based voltage and frequency cont...
Battery energy storage and power electronics based voltage and frequency cont...Battery energy storage and power electronics based voltage and frequency cont...
Battery energy storage and power electronics based voltage and frequency cont...
 
IJSETR-VOL-2-ISSUE-7-1526-1530
IJSETR-VOL-2-ISSUE-7-1526-1530IJSETR-VOL-2-ISSUE-7-1526-1530
IJSETR-VOL-2-ISSUE-7-1526-1530
 
Research Inventy : International Journal of Engineering and Science
Research Inventy : International Journal of Engineering and ScienceResearch Inventy : International Journal of Engineering and Science
Research Inventy : International Journal of Engineering and Science
 
Simulation of various DC-DC converters for photovoltaic system
Simulation of various DC-DC converters for photovoltaic systemSimulation of various DC-DC converters for photovoltaic system
Simulation of various DC-DC converters for photovoltaic system
 
A Novel Three Phase Multi-string Multilevel Inverter with High DC-DC Closed o...
A Novel Three Phase Multi-string Multilevel Inverter with High DC-DC Closed o...A Novel Three Phase Multi-string Multilevel Inverter with High DC-DC Closed o...
A Novel Three Phase Multi-string Multilevel Inverter with High DC-DC Closed o...
 

En vedette

آموزش طراحی کنترل پیش بین مبتنی بر مدل یا MPC در متلب
آموزش طراحی کنترل پیش بین مبتنی بر مدل یا MPC در متلبآموزش طراحی کنترل پیش بین مبتنی بر مدل یا MPC در متلب
آموزش طراحی کنترل پیش بین مبتنی بر مدل یا MPC در متلبfaradars
 
A Voltage Controlled Dstatcom for Power Quality Improvement
A Voltage Controlled Dstatcom for Power Quality ImprovementA Voltage Controlled Dstatcom for Power Quality Improvement
A Voltage Controlled Dstatcom for Power Quality Improvementiosrjce
 
Long Flashover Arresters - EEERulez.BlogSpot.in
Long Flashover Arresters - EEERulez.BlogSpot.inLong Flashover Arresters - EEERulez.BlogSpot.in
Long Flashover Arresters - EEERulez.BlogSpot.inRakesh Bhupathi
 
Infrared Plastic Solar Cell - EEERulez.BlogSpot.in
Infrared Plastic Solar Cell - EEERulez.BlogSpot.inInfrared Plastic Solar Cell - EEERulez.BlogSpot.in
Infrared Plastic Solar Cell - EEERulez.BlogSpot.inRakesh Bhupathi
 
power quality improvement in distrution system using D statcom
power quality improvement in distrution system using D statcompower quality improvement in distrution system using D statcom
power quality improvement in distrution system using D statcom7867867869
 
Power quality using statcom
Power quality using statcomPower quality using statcom
Power quality using statcomAnurag Choudhary
 
Protection Devices and the Lightning
Protection Devices and the LightningProtection Devices and the Lightning
Protection Devices and the LightningAmeen San
 
**Lightning Arrester Presentation**
**Lightning Arrester Presentation****Lightning Arrester Presentation**
**Lightning Arrester Presentation**SKPAMB
 
3d i cs_full_seminar_report
3d i cs_full_seminar_report3d i cs_full_seminar_report
3d i cs_full_seminar_reportsaitejarevathi
 
Enhancement of power quality in distribution system using d statcom
Enhancement of power quality in distribution system using d statcomEnhancement of power quality in distribution system using d statcom
Enhancement of power quality in distribution system using d statcomvasaharish
 
Power quality-disturbances and monitoring Seminar
Power quality-disturbances and monitoring  SeminarPower quality-disturbances and monitoring  Seminar
Power quality-disturbances and monitoring SeminarSurabhi Vasudev
 
POWER QUALITY IMPROVEMENT IN A PV DISTRIBUTION SYSTEM BY USING D-STATCOM
POWER QUALITY IMPROVEMENT IN A PV DISTRIBUTION SYSTEM BY USING D-STATCOMPOWER QUALITY IMPROVEMENT IN A PV DISTRIBUTION SYSTEM BY USING D-STATCOM
POWER QUALITY IMPROVEMENT IN A PV DISTRIBUTION SYSTEM BY USING D-STATCOMpechetti surya venkata subrahmanyam
 
Statcom control scheme for power quality improvement of grid connected wind e...
Statcom control scheme for power quality improvement of grid connected wind e...Statcom control scheme for power quality improvement of grid connected wind e...
Statcom control scheme for power quality improvement of grid connected wind e...Kinnera Kin
 
POWER QUALITY IMPROVEMENT
POWER QUALITY IMPROVEMENTPOWER QUALITY IMPROVEMENT
POWER QUALITY IMPROVEMENTUday Wankar
 

En vedette (20)

آموزش طراحی کنترل پیش بین مبتنی بر مدل یا MPC در متلب
آموزش طراحی کنترل پیش بین مبتنی بر مدل یا MPC در متلبآموزش طراحی کنترل پیش بین مبتنی بر مدل یا MPC در متلب
آموزش طراحی کنترل پیش بین مبتنی بر مدل یا MPC در متلب
 
A Voltage Controlled Dstatcom for Power Quality Improvement
A Voltage Controlled Dstatcom for Power Quality ImprovementA Voltage Controlled Dstatcom for Power Quality Improvement
A Voltage Controlled Dstatcom for Power Quality Improvement
 
Long Flashover Arresters - EEERulez.BlogSpot.in
Long Flashover Arresters - EEERulez.BlogSpot.inLong Flashover Arresters - EEERulez.BlogSpot.in
Long Flashover Arresters - EEERulez.BlogSpot.in
 
Infrared Plastic Solar Cell - EEERulez.BlogSpot.in
Infrared Plastic Solar Cell - EEERulez.BlogSpot.inInfrared Plastic Solar Cell - EEERulez.BlogSpot.in
Infrared Plastic Solar Cell - EEERulez.BlogSpot.in
 
dstatcom
dstatcomdstatcom
dstatcom
 
power quality improvement in distrution system using D statcom
power quality improvement in distrution system using D statcompower quality improvement in distrution system using D statcom
power quality improvement in distrution system using D statcom
 
Lightning Arrestar
Lightning ArrestarLightning Arrestar
Lightning Arrestar
 
Power quality using statcom
Power quality using statcomPower quality using statcom
Power quality using statcom
 
Protection Devices and the Lightning
Protection Devices and the LightningProtection Devices and the Lightning
Protection Devices and the Lightning
 
Lightning arresters
Lightning arrestersLightning arresters
Lightning arresters
 
**Lightning Arrester Presentation**
**Lightning Arrester Presentation****Lightning Arrester Presentation**
**Lightning Arrester Presentation**
 
3d i cs_full_seminar_report
3d i cs_full_seminar_report3d i cs_full_seminar_report
3d i cs_full_seminar_report
 
Enhancement of power quality in distribution system using d statcom
Enhancement of power quality in distribution system using d statcomEnhancement of power quality in distribution system using d statcom
Enhancement of power quality in distribution system using d statcom
 
Power quality-disturbances and monitoring Seminar
Power quality-disturbances and monitoring  SeminarPower quality-disturbances and monitoring  Seminar
Power quality-disturbances and monitoring Seminar
 
Lighting arrester
Lighting arresterLighting arrester
Lighting arrester
 
POWER QUALITY IMPROVEMENT IN A PV DISTRIBUTION SYSTEM BY USING D-STATCOM
POWER QUALITY IMPROVEMENT IN A PV DISTRIBUTION SYSTEM BY USING D-STATCOMPOWER QUALITY IMPROVEMENT IN A PV DISTRIBUTION SYSTEM BY USING D-STATCOM
POWER QUALITY IMPROVEMENT IN A PV DISTRIBUTION SYSTEM BY USING D-STATCOM
 
Statcom control scheme for power quality improvement of grid connected wind e...
Statcom control scheme for power quality improvement of grid connected wind e...Statcom control scheme for power quality improvement of grid connected wind e...
Statcom control scheme for power quality improvement of grid connected wind e...
 
Power quality
Power qualityPower quality
Power quality
 
Power quality.ppt
Power quality.pptPower quality.ppt
Power quality.ppt
 
POWER QUALITY IMPROVEMENT
POWER QUALITY IMPROVEMENTPOWER QUALITY IMPROVEMENT
POWER QUALITY IMPROVEMENT
 

Similaire à PV Hybrid System with DSTATCOM for Residential Applications

Implementation of solar inverter (2)
Implementation of solar inverter (2)Implementation of solar inverter (2)
Implementation of solar inverter (2)vishal gawhale
 
A New Simulation Approach of 3-Φ Transformer-less Grid Connected PV Inverter ...
A New Simulation Approach of 3-Φ Transformer-less Grid Connected PV Inverter ...A New Simulation Approach of 3-Φ Transformer-less Grid Connected PV Inverter ...
A New Simulation Approach of 3-Φ Transformer-less Grid Connected PV Inverter ...IRJET Journal
 
Power Quality Improvement Using Custom Power Devices in Squirrel Cage Inducti...
Power Quality Improvement Using Custom Power Devices in Squirrel Cage Inducti...Power Quality Improvement Using Custom Power Devices in Squirrel Cage Inducti...
Power Quality Improvement Using Custom Power Devices in Squirrel Cage Inducti...IJPEDS-IAES
 
Measurement and Analysis of Power in Hybrid System
Measurement and Analysis of Power in Hybrid SystemMeasurement and Analysis of Power in Hybrid System
Measurement and Analysis of Power in Hybrid Systemijeei-iaes
 
Comparison of upqc and dvr in wind turbine fed fsig under asymmetric faults
Comparison of upqc and dvr in wind turbine fed fsig under asymmetric faultsComparison of upqc and dvr in wind turbine fed fsig under asymmetric faults
Comparison of upqc and dvr in wind turbine fed fsig under asymmetric faultselelijjournal
 
Frequency control in a microgrid including controllable load
Frequency control in a microgrid including controllable loadFrequency control in a microgrid including controllable load
Frequency control in a microgrid including controllable loadIAEME Publication
 
Iaetsd integration of distributed solar power generation
Iaetsd integration of distributed solar power generationIaetsd integration of distributed solar power generation
Iaetsd integration of distributed solar power generationIaetsd Iaetsd
 
A Three Phase Multi Level Converter for grid Connected PV System
A Three Phase Multi Level Converter for grid Connected PV SystemA Three Phase Multi Level Converter for grid Connected PV System
A Three Phase Multi Level Converter for grid Connected PV SystemIAES-IJPEDS
 
Improvement of Power Quality using Fuzzy Logic Controller in Grid Connected P...
Improvement of Power Quality using Fuzzy Logic Controller in Grid Connected P...Improvement of Power Quality using Fuzzy Logic Controller in Grid Connected P...
Improvement of Power Quality using Fuzzy Logic Controller in Grid Connected P...IAES-IJPEDS
 
Operation and Control of Grid Connected Hybrid AC/DC Microgrid using Various RES
Operation and Control of Grid Connected Hybrid AC/DC Microgrid using Various RESOperation and Control of Grid Connected Hybrid AC/DC Microgrid using Various RES
Operation and Control of Grid Connected Hybrid AC/DC Microgrid using Various RESIAES-IJPEDS
 
A solar pv based multistage grid tie inverter
A solar pv based multistage grid tie inverterA solar pv based multistage grid tie inverter
A solar pv based multistage grid tie inverterAlexander Decker
 
POWER QUALITY IMPROVEMENT METHODOLOGY IN MICROGRID: A REVIEW
POWER QUALITY IMPROVEMENT METHODOLOGY IN MICROGRID: A REVIEWPOWER QUALITY IMPROVEMENT METHODOLOGY IN MICROGRID: A REVIEW
POWER QUALITY IMPROVEMENT METHODOLOGY IN MICROGRID: A REVIEWIRJET Journal
 
IRJET- A Systematic Approach to Design Single Phase Transformer Less Inve...
IRJET-  	  A Systematic Approach to Design Single Phase Transformer Less Inve...IRJET-  	  A Systematic Approach to Design Single Phase Transformer Less Inve...
IRJET- A Systematic Approach to Design Single Phase Transformer Less Inve...IRJET Journal
 
Electric Vehicle as an Energy Storage for Grid Connected Solar Power System
Electric Vehicle as an Energy Storage for Grid Connected Solar Power SystemElectric Vehicle as an Energy Storage for Grid Connected Solar Power System
Electric Vehicle as an Energy Storage for Grid Connected Solar Power SystemIAES-IJPEDS
 
Performance Analysis of DC Micro Grid with PV-Fuel Cell Hybrid Generation
Performance Analysis of DC Micro Grid with PV-Fuel Cell Hybrid GenerationPerformance Analysis of DC Micro Grid with PV-Fuel Cell Hybrid Generation
Performance Analysis of DC Micro Grid with PV-Fuel Cell Hybrid GenerationIJMREMJournal
 

Similaire à PV Hybrid System with DSTATCOM for Residential Applications (20)

Implementation of solar inverter (2)
Implementation of solar inverter (2)Implementation of solar inverter (2)
Implementation of solar inverter (2)
 
A New Simulation Approach of 3-Φ Transformer-less Grid Connected PV Inverter ...
A New Simulation Approach of 3-Φ Transformer-less Grid Connected PV Inverter ...A New Simulation Approach of 3-Φ Transformer-less Grid Connected PV Inverter ...
A New Simulation Approach of 3-Φ Transformer-less Grid Connected PV Inverter ...
 
Power Quality Improvement Using Custom Power Devices in Squirrel Cage Inducti...
Power Quality Improvement Using Custom Power Devices in Squirrel Cage Inducti...Power Quality Improvement Using Custom Power Devices in Squirrel Cage Inducti...
Power Quality Improvement Using Custom Power Devices in Squirrel Cage Inducti...
 
Measurement and Analysis of Power in Hybrid System
Measurement and Analysis of Power in Hybrid SystemMeasurement and Analysis of Power in Hybrid System
Measurement and Analysis of Power in Hybrid System
 
Comparison of upqc and dvr in wind turbine fed fsig under asymmetric faults
Comparison of upqc and dvr in wind turbine fed fsig under asymmetric faultsComparison of upqc and dvr in wind turbine fed fsig under asymmetric faults
Comparison of upqc and dvr in wind turbine fed fsig under asymmetric faults
 
Modeling and Simulation of Grid Connected PV Generation System Using Matlab/S...
Modeling and Simulation of Grid Connected PV Generation System Using Matlab/S...Modeling and Simulation of Grid Connected PV Generation System Using Matlab/S...
Modeling and Simulation of Grid Connected PV Generation System Using Matlab/S...
 
Frequency control in a microgrid including controllable load
Frequency control in a microgrid including controllable loadFrequency control in a microgrid including controllable load
Frequency control in a microgrid including controllable load
 
40620130101002
4062013010100240620130101002
40620130101002
 
Gm3611661171
Gm3611661171Gm3611661171
Gm3611661171
 
IJET-V2I6P10
IJET-V2I6P10IJET-V2I6P10
IJET-V2I6P10
 
Iaetsd integration of distributed solar power generation
Iaetsd integration of distributed solar power generationIaetsd integration of distributed solar power generation
Iaetsd integration of distributed solar power generation
 
A Three Phase Multi Level Converter for grid Connected PV System
A Three Phase Multi Level Converter for grid Connected PV SystemA Three Phase Multi Level Converter for grid Connected PV System
A Three Phase Multi Level Converter for grid Connected PV System
 
Af04603185190
Af04603185190Af04603185190
Af04603185190
 
Improvement of Power Quality using Fuzzy Logic Controller in Grid Connected P...
Improvement of Power Quality using Fuzzy Logic Controller in Grid Connected P...Improvement of Power Quality using Fuzzy Logic Controller in Grid Connected P...
Improvement of Power Quality using Fuzzy Logic Controller in Grid Connected P...
 
Operation and Control of Grid Connected Hybrid AC/DC Microgrid using Various RES
Operation and Control of Grid Connected Hybrid AC/DC Microgrid using Various RESOperation and Control of Grid Connected Hybrid AC/DC Microgrid using Various RES
Operation and Control of Grid Connected Hybrid AC/DC Microgrid using Various RES
 
A solar pv based multistage grid tie inverter
A solar pv based multistage grid tie inverterA solar pv based multistage grid tie inverter
A solar pv based multistage grid tie inverter
 
POWER QUALITY IMPROVEMENT METHODOLOGY IN MICROGRID: A REVIEW
POWER QUALITY IMPROVEMENT METHODOLOGY IN MICROGRID: A REVIEWPOWER QUALITY IMPROVEMENT METHODOLOGY IN MICROGRID: A REVIEW
POWER QUALITY IMPROVEMENT METHODOLOGY IN MICROGRID: A REVIEW
 
IRJET- A Systematic Approach to Design Single Phase Transformer Less Inve...
IRJET-  	  A Systematic Approach to Design Single Phase Transformer Less Inve...IRJET-  	  A Systematic Approach to Design Single Phase Transformer Less Inve...
IRJET- A Systematic Approach to Design Single Phase Transformer Less Inve...
 
Electric Vehicle as an Energy Storage for Grid Connected Solar Power System
Electric Vehicle as an Energy Storage for Grid Connected Solar Power SystemElectric Vehicle as an Energy Storage for Grid Connected Solar Power System
Electric Vehicle as an Energy Storage for Grid Connected Solar Power System
 
Performance Analysis of DC Micro Grid with PV-Fuel Cell Hybrid Generation
Performance Analysis of DC Micro Grid with PV-Fuel Cell Hybrid GenerationPerformance Analysis of DC Micro Grid with PV-Fuel Cell Hybrid Generation
Performance Analysis of DC Micro Grid with PV-Fuel Cell Hybrid Generation
 

Plus de IDES Editor

Power System State Estimation - A Review
Power System State Estimation - A ReviewPower System State Estimation - A Review
Power System State Estimation - A ReviewIDES Editor
 
Artificial Intelligence Technique based Reactive Power Planning Incorporating...
Artificial Intelligence Technique based Reactive Power Planning Incorporating...Artificial Intelligence Technique based Reactive Power Planning Incorporating...
Artificial Intelligence Technique based Reactive Power Planning Incorporating...IDES Editor
 
Design and Performance Analysis of Genetic based PID-PSS with SVC in a Multi-...
Design and Performance Analysis of Genetic based PID-PSS with SVC in a Multi-...Design and Performance Analysis of Genetic based PID-PSS with SVC in a Multi-...
Design and Performance Analysis of Genetic based PID-PSS with SVC in a Multi-...IDES Editor
 
Optimal Placement of DG for Loss Reduction and Voltage Sag Mitigation in Radi...
Optimal Placement of DG for Loss Reduction and Voltage Sag Mitigation in Radi...Optimal Placement of DG for Loss Reduction and Voltage Sag Mitigation in Radi...
Optimal Placement of DG for Loss Reduction and Voltage Sag Mitigation in Radi...IDES Editor
 
Line Losses in the 14-Bus Power System Network using UPFC
Line Losses in the 14-Bus Power System Network using UPFCLine Losses in the 14-Bus Power System Network using UPFC
Line Losses in the 14-Bus Power System Network using UPFCIDES Editor
 
Study of Structural Behaviour of Gravity Dam with Various Features of Gallery...
Study of Structural Behaviour of Gravity Dam with Various Features of Gallery...Study of Structural Behaviour of Gravity Dam with Various Features of Gallery...
Study of Structural Behaviour of Gravity Dam with Various Features of Gallery...IDES Editor
 
Assessing Uncertainty of Pushover Analysis to Geometric Modeling
Assessing Uncertainty of Pushover Analysis to Geometric ModelingAssessing Uncertainty of Pushover Analysis to Geometric Modeling
Assessing Uncertainty of Pushover Analysis to Geometric ModelingIDES Editor
 
Secure Multi-Party Negotiation: An Analysis for Electronic Payments in Mobile...
Secure Multi-Party Negotiation: An Analysis for Electronic Payments in Mobile...Secure Multi-Party Negotiation: An Analysis for Electronic Payments in Mobile...
Secure Multi-Party Negotiation: An Analysis for Electronic Payments in Mobile...IDES Editor
 
Selfish Node Isolation & Incentivation using Progressive Thresholds
Selfish Node Isolation & Incentivation using Progressive ThresholdsSelfish Node Isolation & Incentivation using Progressive Thresholds
Selfish Node Isolation & Incentivation using Progressive ThresholdsIDES Editor
 
Various OSI Layer Attacks and Countermeasure to Enhance the Performance of WS...
Various OSI Layer Attacks and Countermeasure to Enhance the Performance of WS...Various OSI Layer Attacks and Countermeasure to Enhance the Performance of WS...
Various OSI Layer Attacks and Countermeasure to Enhance the Performance of WS...IDES Editor
 
Responsive Parameter based an AntiWorm Approach to Prevent Wormhole Attack in...
Responsive Parameter based an AntiWorm Approach to Prevent Wormhole Attack in...Responsive Parameter based an AntiWorm Approach to Prevent Wormhole Attack in...
Responsive Parameter based an AntiWorm Approach to Prevent Wormhole Attack in...IDES Editor
 
Cloud Security and Data Integrity with Client Accountability Framework
Cloud Security and Data Integrity with Client Accountability FrameworkCloud Security and Data Integrity with Client Accountability Framework
Cloud Security and Data Integrity with Client Accountability FrameworkIDES Editor
 
Genetic Algorithm based Layered Detection and Defense of HTTP Botnet
Genetic Algorithm based Layered Detection and Defense of HTTP BotnetGenetic Algorithm based Layered Detection and Defense of HTTP Botnet
Genetic Algorithm based Layered Detection and Defense of HTTP BotnetIDES Editor
 
Enhancing Data Storage Security in Cloud Computing Through Steganography
Enhancing Data Storage Security in Cloud Computing Through SteganographyEnhancing Data Storage Security in Cloud Computing Through Steganography
Enhancing Data Storage Security in Cloud Computing Through SteganographyIDES Editor
 
Low Energy Routing for WSN’s
Low Energy Routing for WSN’sLow Energy Routing for WSN’s
Low Energy Routing for WSN’sIDES Editor
 
Permutation of Pixels within the Shares of Visual Cryptography using KBRP for...
Permutation of Pixels within the Shares of Visual Cryptography using KBRP for...Permutation of Pixels within the Shares of Visual Cryptography using KBRP for...
Permutation of Pixels within the Shares of Visual Cryptography using KBRP for...IDES Editor
 
Rotman Lens Performance Analysis
Rotman Lens Performance AnalysisRotman Lens Performance Analysis
Rotman Lens Performance AnalysisIDES Editor
 
Band Clustering for the Lossless Compression of AVIRIS Hyperspectral Images
Band Clustering for the Lossless Compression of AVIRIS Hyperspectral ImagesBand Clustering for the Lossless Compression of AVIRIS Hyperspectral Images
Band Clustering for the Lossless Compression of AVIRIS Hyperspectral ImagesIDES Editor
 
Microelectronic Circuit Analogous to Hydrogen Bonding Network in Active Site ...
Microelectronic Circuit Analogous to Hydrogen Bonding Network in Active Site ...Microelectronic Circuit Analogous to Hydrogen Bonding Network in Active Site ...
Microelectronic Circuit Analogous to Hydrogen Bonding Network in Active Site ...IDES Editor
 
Texture Unit based Monocular Real-world Scene Classification using SOM and KN...
Texture Unit based Monocular Real-world Scene Classification using SOM and KN...Texture Unit based Monocular Real-world Scene Classification using SOM and KN...
Texture Unit based Monocular Real-world Scene Classification using SOM and KN...IDES Editor
 

Plus de IDES Editor (20)

Power System State Estimation - A Review
Power System State Estimation - A ReviewPower System State Estimation - A Review
Power System State Estimation - A Review
 
Artificial Intelligence Technique based Reactive Power Planning Incorporating...
Artificial Intelligence Technique based Reactive Power Planning Incorporating...Artificial Intelligence Technique based Reactive Power Planning Incorporating...
Artificial Intelligence Technique based Reactive Power Planning Incorporating...
 
Design and Performance Analysis of Genetic based PID-PSS with SVC in a Multi-...
Design and Performance Analysis of Genetic based PID-PSS with SVC in a Multi-...Design and Performance Analysis of Genetic based PID-PSS with SVC in a Multi-...
Design and Performance Analysis of Genetic based PID-PSS with SVC in a Multi-...
 
Optimal Placement of DG for Loss Reduction and Voltage Sag Mitigation in Radi...
Optimal Placement of DG for Loss Reduction and Voltage Sag Mitigation in Radi...Optimal Placement of DG for Loss Reduction and Voltage Sag Mitigation in Radi...
Optimal Placement of DG for Loss Reduction and Voltage Sag Mitigation in Radi...
 
Line Losses in the 14-Bus Power System Network using UPFC
Line Losses in the 14-Bus Power System Network using UPFCLine Losses in the 14-Bus Power System Network using UPFC
Line Losses in the 14-Bus Power System Network using UPFC
 
Study of Structural Behaviour of Gravity Dam with Various Features of Gallery...
Study of Structural Behaviour of Gravity Dam with Various Features of Gallery...Study of Structural Behaviour of Gravity Dam with Various Features of Gallery...
Study of Structural Behaviour of Gravity Dam with Various Features of Gallery...
 
Assessing Uncertainty of Pushover Analysis to Geometric Modeling
Assessing Uncertainty of Pushover Analysis to Geometric ModelingAssessing Uncertainty of Pushover Analysis to Geometric Modeling
Assessing Uncertainty of Pushover Analysis to Geometric Modeling
 
Secure Multi-Party Negotiation: An Analysis for Electronic Payments in Mobile...
Secure Multi-Party Negotiation: An Analysis for Electronic Payments in Mobile...Secure Multi-Party Negotiation: An Analysis for Electronic Payments in Mobile...
Secure Multi-Party Negotiation: An Analysis for Electronic Payments in Mobile...
 
Selfish Node Isolation & Incentivation using Progressive Thresholds
Selfish Node Isolation & Incentivation using Progressive ThresholdsSelfish Node Isolation & Incentivation using Progressive Thresholds
Selfish Node Isolation & Incentivation using Progressive Thresholds
 
Various OSI Layer Attacks and Countermeasure to Enhance the Performance of WS...
Various OSI Layer Attacks and Countermeasure to Enhance the Performance of WS...Various OSI Layer Attacks and Countermeasure to Enhance the Performance of WS...
Various OSI Layer Attacks and Countermeasure to Enhance the Performance of WS...
 
Responsive Parameter based an AntiWorm Approach to Prevent Wormhole Attack in...
Responsive Parameter based an AntiWorm Approach to Prevent Wormhole Attack in...Responsive Parameter based an AntiWorm Approach to Prevent Wormhole Attack in...
Responsive Parameter based an AntiWorm Approach to Prevent Wormhole Attack in...
 
Cloud Security and Data Integrity with Client Accountability Framework
Cloud Security and Data Integrity with Client Accountability FrameworkCloud Security and Data Integrity with Client Accountability Framework
Cloud Security and Data Integrity with Client Accountability Framework
 
Genetic Algorithm based Layered Detection and Defense of HTTP Botnet
Genetic Algorithm based Layered Detection and Defense of HTTP BotnetGenetic Algorithm based Layered Detection and Defense of HTTP Botnet
Genetic Algorithm based Layered Detection and Defense of HTTP Botnet
 
Enhancing Data Storage Security in Cloud Computing Through Steganography
Enhancing Data Storage Security in Cloud Computing Through SteganographyEnhancing Data Storage Security in Cloud Computing Through Steganography
Enhancing Data Storage Security in Cloud Computing Through Steganography
 
Low Energy Routing for WSN’s
Low Energy Routing for WSN’sLow Energy Routing for WSN’s
Low Energy Routing for WSN’s
 
Permutation of Pixels within the Shares of Visual Cryptography using KBRP for...
Permutation of Pixels within the Shares of Visual Cryptography using KBRP for...Permutation of Pixels within the Shares of Visual Cryptography using KBRP for...
Permutation of Pixels within the Shares of Visual Cryptography using KBRP for...
 
Rotman Lens Performance Analysis
Rotman Lens Performance AnalysisRotman Lens Performance Analysis
Rotman Lens Performance Analysis
 
Band Clustering for the Lossless Compression of AVIRIS Hyperspectral Images
Band Clustering for the Lossless Compression of AVIRIS Hyperspectral ImagesBand Clustering for the Lossless Compression of AVIRIS Hyperspectral Images
Band Clustering for the Lossless Compression of AVIRIS Hyperspectral Images
 
Microelectronic Circuit Analogous to Hydrogen Bonding Network in Active Site ...
Microelectronic Circuit Analogous to Hydrogen Bonding Network in Active Site ...Microelectronic Circuit Analogous to Hydrogen Bonding Network in Active Site ...
Microelectronic Circuit Analogous to Hydrogen Bonding Network in Active Site ...
 
Texture Unit based Monocular Real-world Scene Classification using SOM and KN...
Texture Unit based Monocular Real-world Scene Classification using SOM and KN...Texture Unit based Monocular Real-world Scene Classification using SOM and KN...
Texture Unit based Monocular Real-world Scene Classification using SOM and KN...
 

Dernier

Millenials and Fillennials (Ethical Challenge and Responses).pptx
Millenials and Fillennials (Ethical Challenge and Responses).pptxMillenials and Fillennials (Ethical Challenge and Responses).pptx
Millenials and Fillennials (Ethical Challenge and Responses).pptxJanEmmanBrigoli
 
THEORIES OF ORGANIZATION-PUBLIC ADMINISTRATION
THEORIES OF ORGANIZATION-PUBLIC ADMINISTRATIONTHEORIES OF ORGANIZATION-PUBLIC ADMINISTRATION
THEORIES OF ORGANIZATION-PUBLIC ADMINISTRATIONHumphrey A Beña
 
ENG 5 Q4 WEEk 1 DAY 1 Restate sentences heard in one’s own words. Use appropr...
ENG 5 Q4 WEEk 1 DAY 1 Restate sentences heard in one’s own words. Use appropr...ENG 5 Q4 WEEk 1 DAY 1 Restate sentences heard in one’s own words. Use appropr...
ENG 5 Q4 WEEk 1 DAY 1 Restate sentences heard in one’s own words. Use appropr...JojoEDelaCruz
 
4.16.24 Poverty and Precarity--Desmond.pptx
4.16.24 Poverty and Precarity--Desmond.pptx4.16.24 Poverty and Precarity--Desmond.pptx
4.16.24 Poverty and Precarity--Desmond.pptxmary850239
 
The Contemporary World: The Globalization of World Politics
The Contemporary World: The Globalization of World PoliticsThe Contemporary World: The Globalization of World Politics
The Contemporary World: The Globalization of World PoliticsRommel Regala
 
Influencing policy (training slides from Fast Track Impact)
Influencing policy (training slides from Fast Track Impact)Influencing policy (training slides from Fast Track Impact)
Influencing policy (training slides from Fast Track Impact)Mark Reed
 
AUDIENCE THEORY -CULTIVATION THEORY - GERBNER.pptx
AUDIENCE THEORY -CULTIVATION THEORY -  GERBNER.pptxAUDIENCE THEORY -CULTIVATION THEORY -  GERBNER.pptx
AUDIENCE THEORY -CULTIVATION THEORY - GERBNER.pptxiammrhaywood
 
Oppenheimer Film Discussion for Philosophy and Film
Oppenheimer Film Discussion for Philosophy and FilmOppenheimer Film Discussion for Philosophy and Film
Oppenheimer Film Discussion for Philosophy and FilmStan Meyer
 
MULTIDISCIPLINRY NATURE OF THE ENVIRONMENTAL STUDIES.pptx
MULTIDISCIPLINRY NATURE OF THE ENVIRONMENTAL STUDIES.pptxMULTIDISCIPLINRY NATURE OF THE ENVIRONMENTAL STUDIES.pptx
MULTIDISCIPLINRY NATURE OF THE ENVIRONMENTAL STUDIES.pptxAnupkumar Sharma
 
Expanded definition: technical and operational
Expanded definition: technical and operationalExpanded definition: technical and operational
Expanded definition: technical and operationalssuser3e220a
 
ROLES IN A STAGE PRODUCTION in arts.pptx
ROLES IN A STAGE PRODUCTION in arts.pptxROLES IN A STAGE PRODUCTION in arts.pptx
ROLES IN A STAGE PRODUCTION in arts.pptxVanesaIglesias10
 
4.18.24 Movement Legacies, Reflection, and Review.pptx
4.18.24 Movement Legacies, Reflection, and Review.pptx4.18.24 Movement Legacies, Reflection, and Review.pptx
4.18.24 Movement Legacies, Reflection, and Review.pptxmary850239
 
Measures of Position DECILES for ungrouped data
Measures of Position DECILES for ungrouped dataMeasures of Position DECILES for ungrouped data
Measures of Position DECILES for ungrouped dataBabyAnnMotar
 
Keynote by Prof. Wurzer at Nordex about IP-design
Keynote by Prof. Wurzer at Nordex about IP-designKeynote by Prof. Wurzer at Nordex about IP-design
Keynote by Prof. Wurzer at Nordex about IP-designMIPLM
 
Presentation Activity 2. Unit 3 transv.pptx
Presentation Activity 2. Unit 3 transv.pptxPresentation Activity 2. Unit 3 transv.pptx
Presentation Activity 2. Unit 3 transv.pptxRosabel UA
 
ICS2208 Lecture6 Notes for SL spaces.pdf
ICS2208 Lecture6 Notes for SL spaces.pdfICS2208 Lecture6 Notes for SL spaces.pdf
ICS2208 Lecture6 Notes for SL spaces.pdfVanessa Camilleri
 

Dernier (20)

Millenials and Fillennials (Ethical Challenge and Responses).pptx
Millenials and Fillennials (Ethical Challenge and Responses).pptxMillenials and Fillennials (Ethical Challenge and Responses).pptx
Millenials and Fillennials (Ethical Challenge and Responses).pptx
 
THEORIES OF ORGANIZATION-PUBLIC ADMINISTRATION
THEORIES OF ORGANIZATION-PUBLIC ADMINISTRATIONTHEORIES OF ORGANIZATION-PUBLIC ADMINISTRATION
THEORIES OF ORGANIZATION-PUBLIC ADMINISTRATION
 
ENG 5 Q4 WEEk 1 DAY 1 Restate sentences heard in one’s own words. Use appropr...
ENG 5 Q4 WEEk 1 DAY 1 Restate sentences heard in one’s own words. Use appropr...ENG 5 Q4 WEEk 1 DAY 1 Restate sentences heard in one’s own words. Use appropr...
ENG 5 Q4 WEEk 1 DAY 1 Restate sentences heard in one’s own words. Use appropr...
 
INCLUSIVE EDUCATION PRACTICES FOR TEACHERS AND TRAINERS.pptx
INCLUSIVE EDUCATION PRACTICES FOR TEACHERS AND TRAINERS.pptxINCLUSIVE EDUCATION PRACTICES FOR TEACHERS AND TRAINERS.pptx
INCLUSIVE EDUCATION PRACTICES FOR TEACHERS AND TRAINERS.pptx
 
4.16.24 Poverty and Precarity--Desmond.pptx
4.16.24 Poverty and Precarity--Desmond.pptx4.16.24 Poverty and Precarity--Desmond.pptx
4.16.24 Poverty and Precarity--Desmond.pptx
 
The Contemporary World: The Globalization of World Politics
The Contemporary World: The Globalization of World PoliticsThe Contemporary World: The Globalization of World Politics
The Contemporary World: The Globalization of World Politics
 
Influencing policy (training slides from Fast Track Impact)
Influencing policy (training slides from Fast Track Impact)Influencing policy (training slides from Fast Track Impact)
Influencing policy (training slides from Fast Track Impact)
 
AUDIENCE THEORY -CULTIVATION THEORY - GERBNER.pptx
AUDIENCE THEORY -CULTIVATION THEORY -  GERBNER.pptxAUDIENCE THEORY -CULTIVATION THEORY -  GERBNER.pptx
AUDIENCE THEORY -CULTIVATION THEORY - GERBNER.pptx
 
Oppenheimer Film Discussion for Philosophy and Film
Oppenheimer Film Discussion for Philosophy and FilmOppenheimer Film Discussion for Philosophy and Film
Oppenheimer Film Discussion for Philosophy and Film
 
YOUVE GOT EMAIL_FINALS_EL_DORADO_2024.pptx
YOUVE GOT EMAIL_FINALS_EL_DORADO_2024.pptxYOUVE GOT EMAIL_FINALS_EL_DORADO_2024.pptx
YOUVE GOT EMAIL_FINALS_EL_DORADO_2024.pptx
 
MULTIDISCIPLINRY NATURE OF THE ENVIRONMENTAL STUDIES.pptx
MULTIDISCIPLINRY NATURE OF THE ENVIRONMENTAL STUDIES.pptxMULTIDISCIPLINRY NATURE OF THE ENVIRONMENTAL STUDIES.pptx
MULTIDISCIPLINRY NATURE OF THE ENVIRONMENTAL STUDIES.pptx
 
Expanded definition: technical and operational
Expanded definition: technical and operationalExpanded definition: technical and operational
Expanded definition: technical and operational
 
ROLES IN A STAGE PRODUCTION in arts.pptx
ROLES IN A STAGE PRODUCTION in arts.pptxROLES IN A STAGE PRODUCTION in arts.pptx
ROLES IN A STAGE PRODUCTION in arts.pptx
 
4.18.24 Movement Legacies, Reflection, and Review.pptx
4.18.24 Movement Legacies, Reflection, and Review.pptx4.18.24 Movement Legacies, Reflection, and Review.pptx
4.18.24 Movement Legacies, Reflection, and Review.pptx
 
FINALS_OF_LEFT_ON_C'N_EL_DORADO_2024.pptx
FINALS_OF_LEFT_ON_C'N_EL_DORADO_2024.pptxFINALS_OF_LEFT_ON_C'N_EL_DORADO_2024.pptx
FINALS_OF_LEFT_ON_C'N_EL_DORADO_2024.pptx
 
Measures of Position DECILES for ungrouped data
Measures of Position DECILES for ungrouped dataMeasures of Position DECILES for ungrouped data
Measures of Position DECILES for ungrouped data
 
Keynote by Prof. Wurzer at Nordex about IP-design
Keynote by Prof. Wurzer at Nordex about IP-designKeynote by Prof. Wurzer at Nordex about IP-design
Keynote by Prof. Wurzer at Nordex about IP-design
 
Presentation Activity 2. Unit 3 transv.pptx
Presentation Activity 2. Unit 3 transv.pptxPresentation Activity 2. Unit 3 transv.pptx
Presentation Activity 2. Unit 3 transv.pptx
 
ICS2208 Lecture6 Notes for SL spaces.pdf
ICS2208 Lecture6 Notes for SL spaces.pdfICS2208 Lecture6 Notes for SL spaces.pdf
ICS2208 Lecture6 Notes for SL spaces.pdf
 
LEFT_ON_C'N_ PRELIMS_EL_DORADO_2024.pptx
LEFT_ON_C'N_ PRELIMS_EL_DORADO_2024.pptxLEFT_ON_C'N_ PRELIMS_EL_DORADO_2024.pptx
LEFT_ON_C'N_ PRELIMS_EL_DORADO_2024.pptx
 

PV Hybrid System with DSTATCOM for Residential Applications

  • 1. Full Paper ACEEE Int. J. on Electrical and Power Engineering , Vol. 4, No. 3, November 2013 PV Hybrid System with DSTATCOM for Residential Applications Ch.Venkateswra rao1, S.S.Tulasiram2, B.Brahmaiah3 1 PHD scholar, JNTUK, Kakinada. E-mail: chvr_4581@yahoo.co.in . 2 Professor, JNTUH, Hyderabad, 3 Principal, GEC ,Guntur Abstract- Now a days PV based energy systems are playing a vital role among all the renewable energy sourcesin our day to day life.Proper control should be required to meet the exact load conditions such that it should satisfy the non-linear nature of both the solar irradiance and load. In this paper, a battery is also incorporated along with the PV system to meet the necessary drop due to change in weather conditions. Here, a proper control is achieved by using DSTATCOM to compensate the reactive power. This paper proposes an advanced technique of PWM to generate the gating pulses and applied to a Cascaded H-Bridge multilevel inverter to improve the voltage quality. Here, the entire system is designed to meet the load of Mogulthur (W.G.Dt. Andhra Pradesh). Simulation results are presented through Matlab/Simulink by taking different cases into consideration. Index Terms:- PV system, Stand alone system, DSTATCOM, Power quality. I. INTRODUCTION Today PV based power generation systems are becoming more and more popular, with the increase of energy demand and the concern of environmental pollution around the world. One of the inherent advantages of PV electricity generation is the absence of any mechanical parts. Professionally installed PV arrays are characterized by a long service lifetime, exceeding 20 years, high reliability, and low maintenance requirements, which are highly desirable for remote area power supplies. In sunny locations, PV generators compare favourably with wind generators, despite the higher investment cost for PV modules per peak Watt. Wind generators require regular maintenance and are susceptible to damage in strong winds [2]. However, PV power fluctuates depending on the weather conditions, season, and geographic location, and may cause problems like voltage fluctuation and large frequency deviation in e lectric power system operation [2]. Usually, an energy storage system (i.e., battery) is used to smooth the PV output power fluctuations and then the smoothed power is supplied to the utility [1].Power vs voltage characteristics of PV shows that PV can generate maximum power at particular voltage called as V mpp at corresponding level of irradiance. For best utilization, the PV cells must be operated at their maximum power point. According to perturb and observe (P&O) algorithm, maximum power point tracking (MPPT) is achieved by adjusting the terminal voltage of PV panels to V mpp . 1 © 2013 ACEEE DOI: 01.IJEPE.4.3. 1337 To supply a qualitative power is the main challenge in a stand-alone system. Voltage variations, flickers and harmonic generation are the major power quality (PQ) problems that occur in solar energy conversion system .Those power quality problems may not be tolerated by the customers and hence require mitigation techniques[5].One of the most promising applications of renewable energy technology is the installation of hybrid energy systems in remote areas, where the cost of grid extension is prohibitive and the price for fuel drastically increases with the remoteness of the location. Renewable energy sources, such as photovoltaic (PV), wind energy, or small-scale hydro, provide a realistic alternative to engine-driven generators for electricity generation in remote areas. [3]. This paper concentrates on the control and application of PV-battery hybrid energy systems, which account for the majority of systems installed today. A system to provide uninterrupted power which integrates PV, battery and inverter has been considered. In general four different system configurations are widely developed in stand-alone PV power applications: the centralized inverter system, the string inverter system, the multi-string inverter system and the moduleintegrated inverter system. [4]. Mostly centralized inverter system can be employed for small-scale distributed generation (DG) systems, such as residential power applications. Residential loads are mostly single phase loads; Therefore, in this paper single phase cascaded H-bridge five level inverter is used in the conversion of photovoltaic voltage (D.C) to our Domestic voltage (A.C). Here an advanced technique of unipolar phase disposition pulse width modulation is provided to nullify the switching losses and to improve the output voltage quality. II. SYSTEM DESCRIPTION Photovoltaic inverters become more and more widespread within both private and commercial circles. The isolated power utility used in this paper is shown in Fig. 1. This is actually a parallel PV-battery hybrid power system consisted of a PV generator, battery, a bidirectional converter (MPPT for V), multilevel inverter, DSTATCOM and ac load. In addition, it is assumed that the isolated power utility is not connected to any large power utility and it is always independently operated as a stand-alone system. The battery supplies the load demand when no PV power/few PV power is available.
  • 2. Full Paper ACEEE Int. J. on Electrical and Power Engineering , Vol. 4, No. 3, November 2013 Fig. 1: PV based hybrid power generation system Fig 1(a) Block Diagram of H-bridge inverter Fig. 2: Load profile of Mogultur village, Andhrapradesh, India Cascaded Multilevel H-Bridge Inverter: As seen in the structure of cascaded H-Bridge Invertors in fig.1(a), each H-bridge inverter needs a separate or isolated DC source. This requirement makes the cascaded inverter a perfect fit for utility interface of renewable energy sources such as photo voltaic or fuel cells where isolated dc sources naturally exist. Since the cascaded inverter eliminates custom designed transformers, a tremendous cost reduction can be expected. AC load considered in this paper is taken from Mogultur village, Narspurmandal, West Godavari district, Andhrapradesh state, India. The profile of load for 24 hours is shown in Fig. 2. According to this load, maximum 61.28kW power supply is required to drive the load. However, solar irradiance will not meet 1000W/m2 in Andhrapradesh. Hence, for safe and reliable operation, selection of solar power should be more than 61.28kW. The required rms of single phase is 230V ac50 Hz frequency. To avoid over modulation index, during reactive power and considering loses at LC filter minimum 300V dc is required to maintain 230V rms at load bus. Hence, in this paper, minimum dc link is considered as 300V. For best utilization, the PV cells must be operated at their maximum power point. To extract the maximum power from PV, PV system should operate at voltage corresponding to maximum power, this can achieve by power electronics converter which can regulate the dc link voltage. Considered minimum solar irradiance is 200W/m2. So that selected PV system should operate 300V at 200W/m2 irradiance. The PV module is the result 2 © 2013 ACEEE DOI: 01.IJEPE.4.3.1337 of associating a group of PV cells connected in series and parallel. The TSM305 PV model is available in the market, and it is considered in this paper to implement in Matlab/simulink. In this paper a PV array consist of 9 PV modules. Each module having open circuit voltage as 43.20V, short circuit current is 9.49A, voltage at maximum power (Vmpp) is 36V and current at maximum power is 8.47. The PV cell is shown in Fig. 3(a) and power vs voltage curves of one PV array are shown in Fig. 3(b) with different level of solar irradiance. Fig. 3(b) shows that PV can generate maximum power at particular voltage at corresponding level of irradiance. According to perturb and observe (P&O) algorithm, MPPT is achieved by adjusting the terminal voltage of PV panels to Vmpp. In this paper PV panel is directly connected to the dc bus and P&O algorithm for MPPT is incorporated using dc-dc converter (connected between battery and dc-link). Therefore, dc-dc converter not only controls the dc-link voltage but also acts a MPPT and hence additional MPPT circuit for PV is not required. Since 9 modules are connected in series, Vmpp of PV arrays will vary from 300 to 324V according to solar irradiance (G) varies from 200 to 1000W/m2. Vmpp which is output of P&O algorithm will then act as reference dc-link voltage to dc-dc converter control. The maximum power rating of each array is 2745Wand hence by using 29 arrays in parallel, therefore maximum solar power generation is nearly 80 kW. This can maintain the load demand. In case of PV power is more than the load demand, the surplus power will dump into the battery. Hence the selection of battery is depends on
  • 3. Full Paper ACEEE Int. J. on Electrical and Power Engineering , Vol. 4, No. 3, November 2013 maximum surplus power from PV. However, the minimum load is 17.25kW. Therefore maximum surplus power will be 62.75kW. Considering reliability and safe operation of the system considered 65kW battery which is available in the market. boost converter, the battery voltage can be kept lower as compared to reference dc-link voltage and hence less number of batteries need to be connected in series. In the proposed system battery voltage is kept at about 180 V (i.e 15 batteries each 12V are connected in series). Hence in the design of dc-dc converter control, limiter is connected after generating Vmpp by P&O algorithm which limits the reference voltage of dc-link between 324 V to 300 V. The lower limit of dc voltage (i.e 300V) corresponds to 200 W/m2 irradiance. Hence, for irradiance below 200 W/m2, P&O algorithm acts as constant voltage MPPT algorithm. This is helpful to operate the system during night time and under non sunny days. Matlab based implementation of P&O algorithm is shown in Fig. 3(c). In Fig. 3, inputs are voltage of PV panel and current of PV system. Steep change is decided based on change in power. The output of the system is Vmpp and it is treated as input to controller of dc-dc converter, hence extra converter to track maximum power from PV is not required. Fig. 3: (a) single cell model; (b) P-V curve of one PV array The battery is connected to the dc-link through a dc- dc bidirectional buck-boost converter. Using bidirectional buck- Fig. 3: (c) P&O algorithm inverter control as shown in Fig. 4 (b). Modulation index generated by PI controller is feed to PWM generator so that required pulses are generated by PWM generator according to reference voltage of AC bus (i.e., 230). As far as frequency of output ac voltage is concerned, it can be maintained at specified value by choosing the frequency of sinusoidal reference signal while generating the PWM pulses III. CONTROL OF DC LINK AND AC BUS VOLTAGE Due to variations in the solar irradiation and load; dc-link voltage varies because of power mismatch between sources and load. Hence, it is required to maintain dc-link voltage constant irrespective of variations in solar irradiation and load. Battery is used to maintain the power balance of the system. In this paper, bidirectional buck-boost converter is connected between dc-link and battery to maintain the charging and discharging process corresponding to changes in load and generation power. Hence proper controller design is required to control the dc-link. The controller of buckboost converter is shown in Fig. 4 (a), where two switches are used to control the charging and discharging process. Reference dc-link voltage which is generated from P&O algorithm is compared to dc-link voltage and error is fed to proportional plus integral (PI) controller. The output of PI controller gives the reference battery current. Pulses for two switches (dc-dc converter) are generated with the help of hysteresis current control loop by comparing reference and actual currents of battery. In order to obtain the required pulses an unipolar phase disposition technique is developed and by using necessary logic gates and the obtained pulses are shown below to © 2013 ACEEE DOI: 01.IJEPE.4.3. 1337 Fig. 4: (a) Bidirectional dc –dc converter control, (b) Inverter control 3
  • 4. Full Paper ACEEE Int. J. on Electrical and Power Engineering , Vol. 4, No. 3, November 2013 Block diagram of PWM Generator Figure 5 Logic applied to generate pulses Here, in each H-bridge, 4 power devices are operated at 2 different frequencies i.e., 2 are commutated at low frequency(i.e., fundamental) while other 2 are pulse width modulated at high frequency causes problem of differential switching losses among the switches. So proper logic is implemented in order to give the firing pulses and is shown in (fig.5) The gating pattern generated is shown (fig.9) So, to eliminate this, a hybrid PWM controller is used to mix a) Sequential signal b) Low frequency PWM c) High frequency phase disposition SPWM and to generate appropriate pulses for cascaded inverter and the appropriate results are shown in fig 9(a) and 9(b) Sg12 , Sg42 , Sg32 , Sg22 Generally home loads are consuming reactive power, but PV-Battery cannot supply reactive power because of those are DC sources. In this condition alternate support is required to either supply or compensate the required reactive power by the load. This can achieve by using DSTATCOM [6]. In this paper, DSTATCOM is connected after LC filter and propose controller to compensate required reactive power by load. The controller for DSTATCOM is shown in Fig. 6. For the DSTATCOM controller, compared both reactive powers by load and DSTATCOM The error is given to PI controller and it is generated required modulation index. Pulses are generated with PWM generator by using modulation index generated by PI controller. Generated PWM signals will go to DSTATCOM. Fig.9(a) Gating pulses for first bridge Sg11, Sg41 , Sg31 , Sg21 Fig. 6: DSTATCOM control IV. RESULTS AND DISCUSSIONS The results are carried out by Matlab/simulink and those are discussed by following case studies. Case A: Change in Solar Irradiance: Considered solar irradiance reduced from 1000 to 650W/ m2 at t=4sec. as shown in Fig. 6 (a). For this change, P&O algorithm will track voltage at maximum power (Vref) as shown in Fig. 6(b). Corresponding maximum and power generated by PV system is shown in Fig. 6(c). From Fig. 6(c), it shows the dc to dc converter helps to track the maximum power from Fig. 9(b)Gating pulses for second bridge © 2013 ACEEE DOI: 01.IJEPE.4.3.1337 4
  • 5. Full Paper ACEEE Int. J. on Electrical and Power Engineering , Vol. 4, No. 3, November 2013 PV system. Therefore proposed dc to dc convert not only regulates the dc link voltage it also act as MPPT for PV system. Hence, extra MPPT is not required for PV. Fig. 6: (a) change in irradiance, (b) Vref generated by P&O, (c) PV powers Fig. 8: (a) rms voltage at AC bus, (b) Powers Case B: Change in Load Power (Active power): Now considered load changes from 32.78kW to 59.26kW at t= 2sec. (corresponding 18th and 19th hour as shown in Fig. 2). Maximum load change is considered to show the response of dc-link and AC rms voltage, however, practically solar irradiance is almost zero during this time period. In this case, we considered irradiance is at 650W/m2in simulation results. During this change, dc link voltage is stable and it is depicted in Fig. 7 (a). Corresponding rms voltage at AC bus and various powers in the system is shown in Fig. 7(b) and (c) respectively. From Fig. 7 (a) and (b) it is represents the system maintaining good power quality. Case C: Reactive Power Compensation: In this case, considered irradiance at maximum level and applied 20 kVAR along with 20kW power to the load at t= 3sec. before, t=3 sec. the active power consumed by load is 25kW. Therefore after t=3 sec, power factor will be 0.8 at load bus. In this scenario, DSTATCOM compensate reactive power required by the load so that no need to supply reactive power by inverter which is connected to dc link. The corresponding rms voltage and various powers included in system are shown in Fig. 8(a) and (b) respectively. From Fig 8(a), it is observe that, the output phase rms voltage is almost immune to fluctuations. The rms value of output ac voltage may not give the clear picture of voltage waveform in the transient condition; hence instantaneous current and voltage are presented in Fig. 9 (a) and (b) Fig. 7: (a) dc link voltage, (b) rms voltage at AC bus, (c) Powers © 2013 ACEEE DOI: 01.IJEPE.4.3.1337 5
  • 6. Full Paper ACEEE Int. J. on Electrical and Power Engineering , Vol. 4, No. 3, November 2013 respectively. From Fig. 9 (b) at t=3sec. it is seen that there is no significant rise in the voltage waveform during load transient. The total harmonic distortion (THD) in the output ac voltage is about 5% in all the three phases. Hence it can be established that with the help of PWM switching and a passive LC filter, a satisfactory quality of voltage can be supplied to the loads. The frequency at AC bus is shown in Fig. 10, From Fig. 10, there is no change in frequency with respect to changes in load as well as irradiance. V. CONCLUSION PV-battery based hybrid power generation system for residential application is presented in this paper. Voltage quality is maintained with respect to changes in load and solar irradiance. Proper controllers are designed and achieved proper energy management between various sources and load. Battery is connected through dc-dc bidirectional convert to improve the power quality with respect to changes in solar irradiance and load. P&O algorithm is incorporated to controller of dc-dc bidirectional converter which is connected between dc bus and battery. Hence, dc-dc converter acts as MPPT converter for PV. Therefore, extra circuit is not required to extract the maximum power from PV. DSTATCOM is connected to AC bus to improve voltage quality as well as reactive power compensation. Also a five level multilevel inverter is designed with its advanced PWM technique in order to improve the quality. From results one can observe system maintained good power quality in all the possible conditions. REFERENCES [1] Fig. 10: Response of frequency [2] [3] [4] [5] Fig.11: Instantaneous Voltage at AC bus Fig.11 shows the output voltage wave forms of an cascaded h-bridge five level inverter in which the pv voltage is converted to ac voltage. © 2013 ACEEE DOI: 01.IJEPE.4.3.1337 [6] 6 M. Datta et al, “A Frequency-Control Approach by Photovoltaic Generator in a PV–Diesel Hybrid Power System”, IEEE Transactions on Energy Conversion, Vol. 26, No. 2, June 2011. C. V. Nayar et al, “A Grid-Interactive Photovoltaic Uninterruptible Power Supply System Using Battery Storage and a Back Up Diesel Generator”, IEEE Transactions on Energy Conversion, Vol. 15, No. 3, Sept. 2000. R. W. Wies, et al, “Simulink Model for Economic Analysis and Environmental Impacts of a PV With Diesel-Battery System for Remote Villages”, IEEE Transactions on Power Systems, Vol. 20, No. 2, May 2005 T. Kerekes et al, “A New High-Efficiency Single-Phase Transformer less PV Inverter Topology”, IEEE Transactions on Industrial Electronics, Vol. 58, No. 1, Jan. 2011. Bo Yang et al, “Design and Analysis of a Grid-Connected Photovoltaic Power System” IEEE Transactions on Power Electronics, Vol. 25, No. 4, April 2010. M. K. Mishra et al, “Operation of a DSTATCOM in Voltage Control Mode”, IEEE Transactions on Power Delivery, Vol. 18, No. 1, Jan. 2003.