This confidential home inspection report summarizes the inspection of a home located at 2233 Your Address, Hometown, MN 55023 that was conducted on August 16, 2010 between 7:00 AM to 1:00 PM. The inspection found elevated moisture readings over 20% in some areas of the home, staining on the stucco below windows and on the deck ledger board, and cracks in the stucco cladding. Several issues were also identified with the home's exterior including a lack of weep screed, drip cap flashing, and caulking around windows and where dissimilar materials meet. The report provides detailed moisture level readings and photos documenting findings from the pin probe inspection.
1. Inspection Services & Consulting LLC
26291 Chisholm St NE Isanti MN 55040
Tel: 763-444-7348 Fax: 763-444-6718 Mobile: 763-350-3516
Infrared-Inspector.com mninspector@msn.com
CONFIDENTIAL HOME INSPECTION
PREPARED FOR:
Sample Report
_______________________________________________________________
INSPECTION ADDRESS
2233 Your Address, Hometown, MN 55023
INSPECTION DATE
8/16/2010 7:00 AM to 1:00 PM
This report is the exclusive property of the Inspection Company and the client whose
name appears herewith, and its use by any unauthorized persons is prohibited.
_____________________________________________________________________________________________
This report has been produced in accordance with our signed contract and is subject to the terms and conditions agreed upon therein.
All printed comments and the opinions expressed herein are those of the Inspection Company.
Inspection Narratives - Page 1
2. GENERAL INFORMATION
Inspection Address: 2233 Your Address, Hometown, MN 55023
Inspection Date: 8/16/2010 Time: 7:00 AM to 1:00 PM
Weather: Overcast - Temperature at time of inspection: 58-69
Humidity at time of inspection: 55
Inspected by: Jon Anderson
Client Information: Sample Report
Structure Type: Wood Frame
Foundation Type: Basement
Furnished: Yes
Structure Occupied: Yes
Number of Stories: 1 story walkout
Structure Orientation: South
Estimated Year Built: 2002
Unofficial Sq.Ft.: 4500
People on Site At Time of Inspection: Owners
Report File: Dale Beumer
_____________________________________________________________________________________________
This report has been produced in accordance with our signed contract and is subject to the terms and conditions agreed upon therein.
All printed comments and the opinions expressed herein are those of the Inspection Company.
Inspection Narratives - Page 2
3. Inspection Address: 2233 Your Address, Hometown, MN 55023
Inspection Date/Time: 8/16/2010 7:00 AM to 1:00 PM
_____________________________________________________________________________________________
Summary
SUMMARY
General Information
Informational Conditions
Moisture level readings, inspections, and testing are a snap shot in time which can change over a short period
by storms, rain dry weather patterns, humidity, temperature, lack of maintenance, structural (seismic
movement, grade issues, life style changes, heating and cooling seasons, unrealized storm damage, gutter
and roof ice dams, broken or leaking water pipes, and a host of other issues.
Every effort is made to insure the accuracy of our findings, by using the best state of the art testing equipment
available, However moisture testing is not an exact science. So all elevated moisture readings should be
further explored to verify the readings obtained in this report.
This is not a guarantee that every anomaly or issue will be discovered.
If it is determined that there is structural damage, you should protect your rights.
Contact your builder in writing of the findings, and discuss your options with an attorney.
If there is any part of this inspection report that you do not understand, it is your responsibility to contact us to
clarify the issue.
Moisture wood content readings of 6% to 15% are considered normal, levels of 16% to 19% are cautionary and
could possibly indicate a low level of moisture infiltration, Levels of 20% to 100% are considered elevated and
should be further explored for possible damaged sheathing, framing members, and or a fungal growth
Additional copies of your report are available for $39.00
Home Builder
Informational Conditions
Gorham Homes
Precipitation
Informational Conditions
No Measurable precipitation within the last 24 hours
Weep Screed
Informational Conditions
There is no weep screed installed along the foundation line.
Grade Issues
Informational Conditions
The grade is high in certain areas of your home
Kick Out Flashing
Informational Conditions
Kick out flashing's are installed
Window Details
Informational Conditions
The windows of your home were manufactured by Andersen Windows
_____________________________________________________________________________________________
This report has been produced in accordance with our signed contract and is subject to the terms and conditions agreed upon therein.
All printed comments and the opinions expressed herein are those of the Inspection Company.
Inspection Narratives - Page 3
4. Inspection Address: 2233 Your Address, Hometown, MN 55023
Inspection Date/Time: 8/16/2010 7:00 AM to 1:00 PM
_____________________________________________________________________________________________
Drip Cap Flashing
Informational Conditions
The windows lack drip cap flashing's
Caulking Details
Informational Conditions
The window to stucco joints are not caulked
No caulking at dissimilar materials and breaches of the stucco cladding
Moisture Levels
Informational Conditions
Area(s) of your home have elevated moisture readings over 20% which are noted within the pin probe section
of the report.
Stains
Informational Conditions
There is staining of the stucco below windows and the deck ledger board.
This may or may not indicate moisture intrusion issues.
Cracks
Informational Conditions
There are cracks in the stucco which could indicate a structural condition, seismic movement, or moisture
intrusion. Stucco applied to thin, dry weather or wind when the basecoats were applied, in correct 2-1 or 3-1
ratio with the common sand.
Gutters
Informational Conditions
The home is guttered
Casing Beads
Informational Conditions
There are no casing beads wherever the stucco intersects a hard surface
SHEATHING
Informational Conditions
The sheathing on your home is buildrite
_____________________________________________________________________________________________
This report has been produced in accordance with our signed contract and is subject to the terms and conditions agreed upon therein.
All printed comments and the opinions expressed herein are those of the Inspection Company.
Inspection Narratives - Page 4
5. Inspection Address: 2233 Your Address, Hometown, MN 55023
Inspection Date/Time: 8/16/2010 7:00 AM to 1:00 PM
_____________________________________________________________________________________________
Interior
Miscellaneous conditions
RIM JOIST
Informational Conditions
The insulation of the rim joist cavity where visual was insulated with a foil faced foam insulation, and batten
insulation.
Access was limited due to storage of household items.
There is no moisture staining on the surface of the foil faced foam
clean
rim
joist
FLOOR REGISTERS
Informational Conditions
The floor registers that were accessible were visually inspected for moisture staining.
No staining was noted at this time
floor
registers
are clean
_____________________________________________________________________________________________
This report has been produced in accordance with our signed contract and is subject to the terms and conditions agreed upon therein.
All printed comments and the opinions expressed herein are those of the Inspection Company.
Inspection Narratives - Page 5
6. Inspection Address: 2233 Your Address, Hometown, MN 55023
Inspection Date/Time: 8/16/2010 7:00 AM to 1:00 PM
_____________________________________________________________________________________________
WINDOW STAINS
Informational Conditions
There is moisture staining or damaged finish of the window sill extension jamb area.
This is a high indicator of moisture from within the wall cavity below the window
30+%
moisture
reading
lower
level
bedroom
19%
moisture
reading
PIN PROBE
Informational Conditions
The front elevation of your home was pin probed to the back side of the sheathing from the interior due to the
brick cladding of the exterior.
Area # 1
Dining room area
_____________________________________________________________________________________________
This report has been produced in accordance with our signed contract and is subject to the terms and conditions agreed upon therein.
All printed comments and the opinions expressed herein are those of the Inspection Company.
Inspection Narratives - Page 6
7. Inspection Address: 2233 Your Address, Hometown, MN 55023
Inspection Date/Time: 8/16/2010 7:00 AM to 1:00 PM
_____________________________________________________________________________________________
Area # 1 - Continued
18%
15%
12%
14%
_____________________________________________________________________________________________
This report has been produced in accordance with our signed contract and is subject to the terms and conditions agreed upon therein.
All printed comments and the opinions expressed herein are those of the Inspection Company.
Inspection Narratives - Page 7
8. Inspection Address: 2233 Your Address, Hometown, MN 55023
Inspection Date/Time: 8/16/2010 7:00 AM to 1:00 PM
_____________________________________________________________________________________________
Exterior II
EXTERIOR VISUAL (STUCCO)
KICK OUT FLASHING'S
Informational Conditions
The roof rakes have kick out flashing's installed
kick out
flashing
CASING BEADS
Informational Conditions
There are no casing bead or weep screed separating the stucco from the shingles, and or hard surfaces such as
steps, patios, and driveway surfaces.
no
casing
bead
no
casing
bead
DRIP CAP FLASHING'S
Informational Conditions
There are no drip cap flashing's over the head of the window's and or door's,
Drip cap flashing's should be installed to prevent water intrusion at these locations.
Check with your window manufacturer about proper installation
_____________________________________________________________________________________________
This report has been produced in accordance with our signed contract and is subject to the terms and conditions agreed upon therein.
All printed comments and the opinions expressed herein are those of the Inspection Company.
Inspection Narratives - Page 8
9. Inspection Address: 2233 Your Address, Hometown, MN 55023
Inspection Date/Time: 8/16/2010 7:00 AM to 1:00 PM
_____________________________________________________________________________________________
No Drip Cap Flashing's - Continued
no drip
cap
flashing's
WINDOW ISSUES
Informational Conditions
The window to stucco intersections are not caulked.
Caulking can help prevent water infiltration around the frames
no
caulking
no
caulking
and open
hole in
mortar
joint
_____________________________________________________________________________________________
This report has been produced in accordance with our signed contract and is subject to the terms and conditions agreed upon therein.
All printed comments and the opinions expressed herein are those of the Inspection Company.
Inspection Narratives - Page 9
10. Inspection Address: 2233 Your Address, Hometown, MN 55023
Inspection Date/Time: 8/16/2010 7:00 AM to 1:00 PM
_____________________________________________________________________________________________
No Caulking - Continued
no
caulking
WEEP SCREEDS
Informational Conditions
No weep screed is installed separating the stucco from grade at the foundation line.
Stucco by code is to terminate above the finished grade by 4" to 6" and is not to terminate into the grade
(Earth)
Properly installed weep screed prevents ground moisture from wicking up into the stucco which can attack the
stud wall cavity and cause wood rot and a fungal growth.
Weep screed also provides a separation so that any bulk water that is behind the stucco cladding can drain out.
The weep screed also is used as a guide for the elevation height for any grade or landscape work.
no
weep
screed
STUCCO CRACKING
Informational Conditions
There is cracking of the stucco cladding which resembles a road map.
This type of cracking may indicate the presence of moisture behind the water resistant barrier, especially under
windows, roof rakes, feature boards, and deck ledger boards.
_____________________________________________________________________________________________
This report has been produced in accordance with our signed contract and is subject to the terms and conditions agreed upon therein.
All printed comments and the opinions expressed herein are those of the Inspection Company.
Inspection Narratives - Page 10
11. Inspection Address: 2233 Your Address, Hometown, MN 55023
Inspection Date/Time: 8/16/2010 7:00 AM to 1:00 PM
_____________________________________________________________________________________________
STUCCO STAINING
Informational Conditions
There are stains in the stucco cladding which can indicate moisture intrusion in certain circumstances
CAULKING DETAILS
Informational Conditions
There is no caulking where the stucco meets a dissimilar material such as brick, siding water pipes electrical
boxes, lights or vents
caulk all
breaches
GRADE ISSUES
Informational Conditions
The grade is high on the rear elevation of your home
The grade should be down onto the foundation 4 to 6"
grade
grade is high
is high
_____________________________________________________________________________________________
This report has been produced in accordance with our signed contract and is subject to the terms and conditions agreed upon therein.
All printed comments and the opinions expressed herein are those of the Inspection Company.
Inspection Narratives - Page 11
12. Inspection Address: 2233 Your Address, Hometown, MN 55023
Inspection Date/Time: 8/16/2010 7:00 AM to 1:00 PM
_____________________________________________________________________________________________
The Grade Is High - Continued
grade
grade is high
is high
ROOF LINE VALLEY'S
Informational Conditions
The roof line on the right side of the greatroom is wet and covered with green moss
roofline
is wet
and
moss
covered
GUTTER'S
Informational Conditions
The downspouts are not sealed at the anchors
_____________________________________________________________________________________________
This report has been produced in accordance with our signed contract and is subject to the terms and conditions agreed upon therein.
All printed comments and the opinions expressed herein are those of the Inspection Company.
Inspection Narratives - Page 12
13. Inspection Address: 2233 Your Address, Hometown, MN 55023
Inspection Date/Time: 8/16/2010 7:00 AM to 1:00 PM
_____________________________________________________________________________________________
Downspouts Not Sealed - Continued
downspouts
are not
sealed
FEATURE BOARDS AND QUOINS
Informational Conditions
The feature boards are installed flush with or over the window frame with little slope to the outward edge.
This can cause severe water infiltration
feature
board
over
window
frame
DECK LEDGER BOARDS
Informational Conditions
There is no caulking or bottom flashing at the deck ledger board.
This is a high probability area for water infiltration
_____________________________________________________________________________________________
This report has been produced in accordance with our signed contract and is subject to the terms and conditions agreed upon therein.
All printed comments and the opinions expressed herein are those of the Inspection Company.
Inspection Narratives - Page 13
14. Inspection Address: 2233 Your Address, Hometown, MN 55023
Inspection Date/Time: 8/16/2010 7:00 AM to 1:00 PM
_____________________________________________________________________________________________
No caulking at the deck ledger boards - Continued
no
caulking
or bottom
flashing
BRICK
Informational Conditions
The top of the brick lacks adequate slope outward to drain rainwater
no
slope
There are no visible weep ropes in the brick near grade.
Weep ropes provide for draining of water from behind the brick
_____________________________________________________________________________________________
This report has been produced in accordance with our signed contract and is subject to the terms and conditions agreed upon therein.
All printed comments and the opinions expressed herein are those of the Inspection Company.
Inspection Narratives - Page 14
15. Inspection Address: 2233 Your Address, Hometown, MN 55023
Inspection Date/Time: 8/16/2010 7:00 AM to 1:00 PM
_____________________________________________________________________________________________
No Weep Ropes - Continued
no
visible
weep
ropes
or
tubes
The brick cap flashing is not caulked
no no brick
caulking cap
flashing
_____________________________________________________________________________________________
This report has been produced in accordance with our signed contract and is subject to the terms and conditions agreed upon therein.
All printed comments and the opinions expressed herein are those of the Inspection Company.
Inspection Narratives - Page 15
16. Inspection Address: 2233 Your Address, Hometown, MN 55023
Inspection Date/Time: 8/16/2010 7:00 AM to 1:00 PM
_____________________________________________________________________________________________
Pin Probe
PIN PROBE RESULTS
GENERAL PIN PROBE INFORMATION
Informational Conditions
The following photo's are the results of your pin probe moisture level inspection.
All moisture readings are from the sheathing unless otherwise specified.
All moisture readings are given at the location where they were taken on the photo's.
All readings are of wood moisture content from 6% to 100% with 6% being dry, and 100% being saturated.
Moisture readings of 6% to 15% are considered to be normal,
Moisture readings of 16% to 19% are considered cautionary,
Moisture readings of 20% and higher can support mold growth and wood rot if sustained for more than 36 to 48
hours or more and are considered elevated and should be further evaluated.
If there is an "ss" after a moisture reading on the photo's, this indicates that the sheathing felt soft or
deteriorated when the pin probe holes were drilled, or when the pin probes were inserted.
If there is an "ns" or 0 on the photo's this indicates that no sheathing was detected when the pin probe holes
where drilled, and no reading was obtained, This indicates that the sheathing is deteriorated and or completely
missing. If there is a reading it is generally off a framing member.
If there is a "2" after the moisture reading this indicates that the reading was taken twice for accuracy.
REFERENCE PHOTOS
Informational Conditions
The following photos are for referencing the location of the individual pin probe photos per each elevation
Front Elevation
Rear Elevation
_____________________________________________________________________________________________
This report has been produced in accordance with our signed contract and is subject to the terms and conditions agreed upon therein.
All printed comments and the opinions expressed herein are those of the Inspection Company.
Inspection Narratives - Page 16
17. Inspection Address: 2233 Your Address, Hometown, MN 55023
Inspection Date/Time: 8/16/2010 7:00 AM to 1:00 PM
_____________________________________________________________________________________________
Rear Elevation Reference Photos 1 - Continued
Left Elevation
FRONT ELEVATION
Informational Conditions
FRONT ELEVATION PIN PROBE RESULTS
_____________________________________________________________________________________________
This report has been produced in accordance with our signed contract and is subject to the terms and conditions agreed upon therein.
All printed comments and the opinions expressed herein are those of the Inspection Company.
Inspection Narratives - Page 17
18. Inspection Address: 2233 Your Address, Hometown, MN 55023
Inspection Date/Time: 8/16/2010 7:00 AM to 1:00 PM
_____________________________________________________________________________________________
FRONT ELEVATION 1 - Continued
window
area
tested
from the
6% 8% 8% 7% 7% 7% interior
9%
11%
12%
10%
9% 15%
_____________________________________________________________________________________________
This report has been produced in accordance with our signed contract and is subject to the terms and conditions agreed upon therein.
All printed comments and the opinions expressed herein are those of the Inspection Company.
Inspection Narratives - Page 18
19. Inspection Address: 2233 Your Address, Hometown, MN 55023
Inspection Date/Time: 8/16/2010 7:00 AM to 1:00 PM
_____________________________________________________________________________________________
FRONT ELEVATION 1 - Continued
moisture
stains
under
garage
round
window
RIGHT ELEVATION
Informational Conditions
RIGHT ELEVATION PIN PROBE RESULTS
Garage walls
9%
9%
10%
RIGHT ELEVATION RESULTS
_____________________________________________________________________________________________
This report has been produced in accordance with our signed contract and is subject to the terms and conditions agreed upon therein.
All printed comments and the opinions expressed herein are those of the Inspection Company.
Inspection Narratives - Page 19
20. Inspection Address: 2233 Your Address, Hometown, MN 55023
Inspection Date/Time: 8/16/2010 7:00 AM to 1:00 PM
_____________________________________________________________________________________________
RIGHT ELEVATION 2 - Continued
7%
13%
11% 9%
RIGHT ELEVATION RESULTS
Area under the deck
12%
17% 12%
_____________________________________________________________________________________________
This report has been produced in accordance with our signed contract and is subject to the terms and conditions agreed upon therein.
All printed comments and the opinions expressed herein are those of the Inspection Company.
Inspection Narratives - Page 20
21. Inspection Address: 2233 Your Address, Hometown, MN 55023
Inspection Date/Time: 8/16/2010 7:00 AM to 1:00 PM
_____________________________________________________________________________________________
RIGHT ELEVATION 3 - Continued
19.4%
15%
REAR ELEVATION
Informational Conditions
REAR ELEVATION PIN PROBE RESULTS
left side area
24% 15% 18%
18% 14% 22% 21% 14% 16% 19% 13% 16% 0
16%
ns
REAR ELEVATION PIN PROBE RESULTS
Rear center section
_____________________________________________________________________________________________
This report has been produced in accordance with our signed contract and is subject to the terms and conditions agreed upon therein.
All printed comments and the opinions expressed herein are those of the Inspection Company.
Inspection Narratives - Page 21
22. Inspection Address: 2233 Your Address, Hometown, MN 55023
Inspection Date/Time: 8/16/2010 7:00 AM to 1:00 PM
_____________________________________________________________________________________________
REAR ELEVATION 2 - Continued
11% 17% 17% 17% 23% 11%
ss ss
26% 15% 10%
0 0 0 0 0 19%
ns ns ns ns ns ss
0 14%
0 9%
ns ns
8%
9%
8%
13% 8%
19%
12%
REAR ELEVATION PIN PROBE RESULTS
Right side area
_____________________________________________________________________________________________
This report has been produced in accordance with our signed contract and is subject to the terms and conditions agreed upon therein.
All printed comments and the opinions expressed herein are those of the Inspection Company.
Inspection Narratives - Page 22
23. Inspection Address: 2233 Your Address, Hometown, MN 55023
Inspection Date/Time: 8/16/2010 7:00 AM to 1:00 PM
_____________________________________________________________________________________________
REAR ELEVATION 3 - Continued
19% 17% 12% 19% 11% 17% 23%
16% 21%
16%
LEFT ELEVATION
Informational Conditions
LEFT ELEVATION PIN PROBE RESULTS
_____________________________________________________________________________________________
This report has been produced in accordance with our signed contract and is subject to the terms and conditions agreed upon therein.
All printed comments and the opinions expressed herein are those of the Inspection Company.
Inspection Narratives - Page 23
24. Inspection Address: 2233 Your Address, Hometown, MN 55023
Inspection Date/Time: 8/16/2010 7:00 AM to 1:00 PM
_____________________________________________________________________________________________
LEFT ELEVATION 1 - Continued
9%
sheathing
felt soft
8% 11%
further
exploration
17 is advised
ss
15% 19.1% 19.6% 16%
retaining
blocks
are on the
stud wall
area
99%
11%
_____________________________________________________________________________________________
This report has been produced in accordance with our signed contract and is subject to the terms and conditions agreed upon therein.
All printed comments and the opinions expressed herein are those of the Inspection Company.
Inspection Narratives - Page 24
25. Inspection Address: 2233 Your Address, Hometown, MN 55023
Inspection Date/Time: 8/16/2010 7:00 AM to 1:00 PM
_____________________________________________________________________________________________
_____________________________________________________________________________________________
This report has been produced in accordance with our signed contract and is subject to the terms and conditions agreed upon therein.
All printed comments and the opinions expressed herein are those of the Inspection Company.
Inspection Narratives - Page 25
26. Inspection Address: 2233 Your Address, Hometown, MN 55023
Inspection Date/Time: 8/16/2010 7:00 AM to 1:00 PM
_____________________________________________________________________________________________
CONFIDENTIAL HOME INSPECTION 1
GENERAL INFORMATION 2
Summary 3
SUMMARY 3
Interior 5
Miscellaneous conditions 5
Exterior II 8
EXTERIOR VISUAL (STUCCO) 8
Pin Probe 16
PIN PROBE RESULTS 16
INDEX 25
_____________________________________________________________________________________________
This report has been produced in accordance with our signed contract and is subject to the terms and conditions agreed upon therein.
All printed comments and the opinions expressed herein are those of the Inspection Company.
Inspection Narratives - Page 25
27. Inspection Services & Consulting LLC
26291 Chisholm St NE Isanti MN 55040
Tel: 763-444-7348 Fax: 763-444-6718 Mobile: 763-350-3516
Email Address: mninspector@msn.com
Property Address: 2233 Your Address, Hometown, MN 55023
Inspection Date: 8/16/2010 Time: 7:00 AM to 1:00 PM
763-123-4567
Dear Sample Report:
Thank you for hiring Inspection Services & Consulting LLC to be of service. We hope that you were pleased
with the quality of our service, and that you would recommend us to others. Please read the report carefully,
and call us with any questions that you might have. We remain your consultant, and would be happy to assist
you in any way that we can. We sincerely hope that you and your family will be happy and healthy in your
home.
Sincerely,
Jon Anderson CEI CIT CHI CEI
Inspection Services & Consulting LLC