Preliminary Design Review
      Senior Design Clinic
                  Team 10
Team Members and Roles
   Core Team:
     Jeff Frank (EE) – Team Lead
     Kelvin Kosbab (EE)
     Tim Nguyen (EE)
     Mike Masek (ME)
 Advisor: Ramesh Rajagopalan
 Observers:
     Chris Engelmann (Sponsor)
     Kevin Nicholson (Engineering Coordinator)

                           2
Background
   Smoke from fires and cigarettes differs
    greatly
     Cigarette smoke particles:
      ○ Considerably smaller
      ○ Reduced particle concentration
     Commercial smoke detectors are designed
     for fires
      ○ Insensitive to cigarette smoke




                              3
Problem Statement
   Very challenging for hotels to enforce no
    smoking policies
     Some guests are sensitive to smoke residue
      ○ Discomfort
      ○ Health issues
      ○ Unpleasant odors
     Smoke damage can result in thousands of
     dollars in repair costs
   Customer needs system capable of
    notifying hotel staff of smoking violations

                               4
Statement of Work




              5
Statement of Work
   Deliverables:
     Research documentation
     Design documentation
     Prototype of a cigarette smoke monitoring
      system
     Test specifications
     Data supporting a prototype functioning
      within specifications



                            6
Customer Requirements
   Cost target:
     Detection Unit: < $50
     Monitoring Station: < $1,500
   Size target: < twice fire smoke detectors
     smaller than 8.5” x 8.5” x 3”
 Improved sensitivity over existing
  detectors
 Network capable of 100 room hotel
 Functional under US regulations


                             7
Requirements Validation
Functional Requirement             Validation

   Capable of detecting              Establish controlled tests
    cigarette smoke                     Record conditions
   Minimize false positives          Run in controlled setting
     < 2 per hotel                     Count total false positives
   Latency                           Measure using
     Network: < 20 seconds            timestamp
     Detection: < 5 minutes          Testing in similar room




                               8
What is Smoke?
   Gases
     Carbon monoxide, nitrogen oxide
 Chemicals
     Formeldehyde, acrolene, benzene
   Particulates
     Nicotene, phenol, polyaromatic hydrocarbons
     Size: 100 – 4,000 nm




    http://www.engineeringtoolbox.com/particle-sizes-d_934.html
    http://cancercontrol.cancer.gov/tcrb/monographs/7/m7_5.pdf

                                                                  9
Work Breakdown Structure




  Design choices have little effect on each other


                           12
Smoke Detection
   Type of                     Obscuration Level     Particle Sensitivity Range
   Detector                       (% obs/m)                     (nm)
Ionization                         2.6 – 5.0                  10 - 300
Photoelectric                      6.5 – 13.0              300 – 10,000
Laser                             0.06 – 6.41                   N/A

       Cigarette smoke (average):
           100 nm – 300 nm

       Goal: optimize laser technique
         Increase sensitivity
             ○ Obscuration
             ○ Particle size
         Minimize false positives

                                                14
Ionization Method




                  Smoke Absent                             Smoke Present

http://www.epa.gov/radiation/sources/smoke_ion.html
                                                      15
Ionization Design Tweaks
   Dual chamber sensor
     Rejects fluctuations in humidity and
     atmospheric pressure
   Increase current between plates
     Larger voltage
     Minimize distance




                           16
Implementation Difficulties
 Measuring pico-Amps
 Design and construction of ionization
  chamber
 Radioactive material




                      17
Photoelectric Method




   Smoke Absent        Smoke Present
                  18
Optimization Design Tweaks
   Laser Diode
     Much brighter than
      LED
     635 nm
   Photo-sensor array
     Minimize ambient
     light




                           19
Optimization Design Tweaks

   Optical techniques
     Mirrors
     Lens
     Filters




                         20
Optimization Design Tweaks
 Lock-in Amplifier
     Laser  sine wave
     Photosensor  sine wave


   Noise rejection
     All frequencies components not equal to
     sine wave attenuated
      ○ Ambient light
      ○ High frequency transients


                            21
General Techniques
 Optimize airflow into smoke chamber
 Concentrate airflow to one area
     Laser beam path
   Algorithm rejects dust detection




                         23
Flame Detection
   UV and IR detection in combination

   Used as a secondary sensor
     Applied as an aid for primary sensor
     Increase sampling rate of Photoelectric
      sensor
     Send notification to front desk




                            24
Sensor Nodes:
Microprocessor
   Requirements on microprocessor not
    demanding
     Choose a PIC from Microchip
      ○ Many microprocessors available
     Choose the smallest, cheapest one with
     enough I/O and peripherals

     Requires SPI, timer, sufficient I/O pins




                            25
Wireless Network
   Transmitted Data
     Smoke status
     Flame status
     Room #
     Time Stamp




                       26
Wireless Network Protocol
   IEEE 802.15.4
     Low data rate, Personal Area Networks
      ○ Zigbee
      ○ MiWi
     2.4 GHz – International
      ○ 250 Kbit/s
      ○ Shorter range
     915 MHz – North America
      ○ 40 Kbit/s
      ○ Longer range


                          27
MiWi
   Less complex implementation of ZigBee
     Shorter development time
      ○ MiWi Development Studio
      ○ ZENA


   MiWi standardizes…
     Network protocol
      ○ Software package
     Transceivers


     Hotel room capability: 8,128
     Mesh routing
                            28
Monitoring Station
      Application run on Windows 7 laptop
         USB connected MiWi transceiver (ZENA)



      Option 1: LabVIEW
         Pros: Easiest to implement, most of the
               programming already done
         Cons: License fee, not as flexible, limited
                hardware options (NI hardware only)


http://labviewwiki.org/images/thumb/3/32/LabVIEW_Logo_Vertical_4c.jpg/200px-
LabVIEW_Logo_Vertical_4c.jpg


                                                                               31
Monitoring Station
     Option 2: Java application
        Communication with ZENA via C commands and system
         commands
        Pros: Free, flexible, easy to implement, more
               control, experience in Java programming
        Cons: more coding, more testing




    http://www.digitaltrends.com/computing/most-vulnerable-browser-plugin-think-java-not-flash/




                                                                                   32
Design Summary
 Cigarette Detection
   Smoke detection – Laser (Photoelectric)
   Flame detection – UV & IR

 Wireless    Network
   MiWi

 Monitoring    Station
   Java
   ZENA


                          35
Project Schedule




              37
Budget
 Total Allocated    Budget = $2,500
   ○ Cigarette Detection
      $200
   ○ Wireless Network
      $500
   ○ PCB & Housing
      $400
   ○ Miscellaneous Prototyping
      $300

 Estimated    Cost: $1,400
                           38
QUESTIONS?



    39

Contenu connexe

Tendances

Save today nikon pro staff 3 9 x 40 silver riflescope bdc
Save today nikon pro staff 3 9 x 40 silver riflescope bdcSave today nikon pro staff 3 9 x 40 silver riflescope bdc
Save today nikon pro staff 3 9 x 40 silver riflescope bdcbest top electronic today
 
Synergy 2 single sheet english
Synergy 2 single sheet   englishSynergy 2 single sheet   english
Synergy 2 single sheet englishMaziar Yari
 
Advanced Imaging Services at KU Leuven Libraries Webinar slides
Advanced Imaging Services at KU Leuven Libraries Webinar slidesAdvanced Imaging Services at KU Leuven Libraries Webinar slides
Advanced Imaging Services at KU Leuven Libraries Webinar slidesIMPACT Centre of Competence
 
上海必和 Biotech-life-sciences-headwall超光谱高光谱多光谱
上海必和 Biotech-life-sciences-headwall超光谱高光谱多光谱上海必和 Biotech-life-sciences-headwall超光谱高光谱多光谱
上海必和 Biotech-life-sciences-headwall超光谱高光谱多光谱algous
 
IEC62471 LED Radiation Safety Test
IEC62471 LED Radiation Safety TestIEC62471 LED Radiation Safety Test
IEC62471 LED Radiation Safety Test世满 江
 

Tendances (9)

Low-power Portable Laser Spectroscopic Sensors for Atmospheric CO2 Monitoring
Low-power Portable Laser Spectroscopic Sensors for Atmospheric CO2 MonitoringLow-power Portable Laser Spectroscopic Sensors for Atmospheric CO2 Monitoring
Low-power Portable Laser Spectroscopic Sensors for Atmospheric CO2 Monitoring
 
Save today nikon pro staff 3 9 x 40 silver riflescope bdc
Save today nikon pro staff 3 9 x 40 silver riflescope bdcSave today nikon pro staff 3 9 x 40 silver riflescope bdc
Save today nikon pro staff 3 9 x 40 silver riflescope bdc
 
Synergy 2 single sheet english
Synergy 2 single sheet   englishSynergy 2 single sheet   english
Synergy 2 single sheet english
 
SWIR application - Microscopy
SWIR application - MicroscopySWIR application - Microscopy
SWIR application - Microscopy
 
Advanced Imaging Services at KU Leuven Libraries Webinar slides
Advanced Imaging Services at KU Leuven Libraries Webinar slidesAdvanced Imaging Services at KU Leuven Libraries Webinar slides
Advanced Imaging Services at KU Leuven Libraries Webinar slides
 
上海必和 Biotech-life-sciences-headwall超光谱高光谱多光谱
上海必和 Biotech-life-sciences-headwall超光谱高光谱多光谱上海必和 Biotech-life-sciences-headwall超光谱高光谱多光谱
上海必和 Biotech-life-sciences-headwall超光谱高光谱多光谱
 
IEC62471 LED Radiation Safety Test
IEC62471 LED Radiation Safety TestIEC62471 LED Radiation Safety Test
IEC62471 LED Radiation Safety Test
 
DIGITAL RADIOGRAPHY
DIGITAL RADIOGRAPHYDIGITAL RADIOGRAPHY
DIGITAL RADIOGRAPHY
 
Trotec
TrotecTrotec
Trotec
 

En vedette

Que tanto sabes de peliculas
Que tanto sabes de peliculasQue tanto sabes de peliculas
Que tanto sabes de peliculasCuiGR
 
H mc kinney_bio_original
H mc kinney_bio_originalH mc kinney_bio_original
H mc kinney_bio_originalhmckinney704
 
ACSAT BSBA COMP3
ACSAT BSBA COMP3ACSAT BSBA COMP3
ACSAT BSBA COMP3bacani
 
20141028 lightning talk at staff party of rtc48
20141028 lightning talk at staff party of rtc4820141028 lightning talk at staff party of rtc48
20141028 lightning talk at staff party of rtc48Takao Oyobe
 
Nina Townley - Bishop Montgomery High School
Nina Townley - Bishop Montgomery High SchoolNina Townley - Bishop Montgomery High School
Nina Townley - Bishop Montgomery High SchoolDaniel Gold
 
A gps for 2012 jan 1
A gps for 2012 jan 1A gps for 2012 jan 1
A gps for 2012 jan 1coastpastor
 
Presentation Design for Medical Research Study
Presentation Design for Medical Research Study Presentation Design for Medical Research Study
Presentation Design for Medical Research Study Tina Salacup
 
Animasi pada-presentasi (1) call uhamka
Animasi pada-presentasi (1) call uhamkaAnimasi pada-presentasi (1) call uhamka
Animasi pada-presentasi (1) call uhamkaking_of_natsir
 
ЦНАП м. Івано-Франківськ
ЦНАП м. Івано-ФранківськЦНАП м. Івано-Франківськ
ЦНАП м. Івано-ФранківськOlena Ursu
 
9º fuscaxias 2011
9º fuscaxias   20119º fuscaxias   2011
9º fuscaxias 2011labareda72
 
Art and Action for Flow Towards Results
Art and Action for Flow Towards ResultsArt and Action for Flow Towards Results
Art and Action for Flow Towards ResultsErik Schön
 

En vedette (20)

Que tanto sabes de peliculas
Que tanto sabes de peliculasQue tanto sabes de peliculas
Que tanto sabes de peliculas
 
My subjects
My subjectsMy subjects
My subjects
 
Group7
Group7Group7
Group7
 
H mc kinney_bio_original
H mc kinney_bio_originalH mc kinney_bio_original
H mc kinney_bio_original
 
tarea2
tarea2tarea2
tarea2
 
ACSAT BSBA COMP3
ACSAT BSBA COMP3ACSAT BSBA COMP3
ACSAT BSBA COMP3
 
Hinsdale Nutrition Jeopardy Template
Hinsdale Nutrition Jeopardy TemplateHinsdale Nutrition Jeopardy Template
Hinsdale Nutrition Jeopardy Template
 
20141028 lightning talk at staff party of rtc48
20141028 lightning talk at staff party of rtc4820141028 lightning talk at staff party of rtc48
20141028 lightning talk at staff party of rtc48
 
Group6
Group6Group6
Group6
 
Nina Townley - Bishop Montgomery High School
Nina Townley - Bishop Montgomery High SchoolNina Townley - Bishop Montgomery High School
Nina Townley - Bishop Montgomery High School
 
A gps for 2012 jan 1
A gps for 2012 jan 1A gps for 2012 jan 1
A gps for 2012 jan 1
 
Presentation Design for Medical Research Study
Presentation Design for Medical Research Study Presentation Design for Medical Research Study
Presentation Design for Medical Research Study
 
Eco_Chap_1
Eco_Chap_1Eco_Chap_1
Eco_Chap_1
 
Parent Newsletter
Parent NewsletterParent Newsletter
Parent Newsletter
 
Animasi pada-presentasi (1) call uhamka
Animasi pada-presentasi (1) call uhamkaAnimasi pada-presentasi (1) call uhamka
Animasi pada-presentasi (1) call uhamka
 
ЦНАП м. Івано-Франківськ
ЦНАП м. Івано-ФранківськЦНАП м. Івано-Франківськ
ЦНАП м. Івано-Франківськ
 
9º fuscaxias 2011
9º fuscaxias   20119º fuscaxias   2011
9º fuscaxias 2011
 
Simplex
SimplexSimplex
Simplex
 
MAKALE
MAKALEMAKALE
MAKALE
 
Art and Action for Flow Towards Results
Art and Action for Flow Towards ResultsArt and Action for Flow Towards Results
Art and Action for Flow Towards Results
 

Similaire à Smoke sentry 2_pdr_presentation

Digital Detectors for Industrial Applications-Nityanand Gopalika
Digital Detectors for Industrial Applications-Nityanand GopalikaDigital Detectors for Industrial Applications-Nityanand Gopalika
Digital Detectors for Industrial Applications-Nityanand GopalikaNityanand Gopalika
 
Sigfox Makers Tour - Mexico City
Sigfox Makers Tour - Mexico CitySigfox Makers Tour - Mexico City
Sigfox Makers Tour - Mexico CityNicolas Lesconnec
 
Sci 680 smart air quality sensor
Sci 680 smart air quality sensorSci 680 smart air quality sensor
Sci 680 smart air quality sensorEuropean Tech Serv
 
Track 2 session 4 - st dev con 2016 - opensoftwarex
Track 2   session 4 - st dev con 2016 - opensoftwarexTrack 2   session 4 - st dev con 2016 - opensoftwarex
Track 2 session 4 - st dev con 2016 - opensoftwarexST_World
 
Innovate in new and exciting optical sensing applications in industrial marke...
Innovate in new and exciting optical sensing applications in industrial marke...Innovate in new and exciting optical sensing applications in industrial marke...
Innovate in new and exciting optical sensing applications in industrial marke...Design World
 
intelligent_sensing_for_environmental_&_process_measurement_ppt_ADI.pdf
intelligent_sensing_for_environmental_&_process_measurement_ppt_ADI.pdfintelligent_sensing_for_environmental_&_process_measurement_ppt_ADI.pdf
intelligent_sensing_for_environmental_&_process_measurement_ppt_ADI.pdfFitzgeraldSungkyungP
 
Photonics as enabling technology in the Security and Defense sectors
Photonics as enabling technology in the Security and Defense sectorsPhotonics as enabling technology in the Security and Defense sectors
Photonics as enabling technology in the Security and Defense sectorsJose Pozo
 
Oizom Polludrone > Smart Environmental Monitoring Solution
Oizom Polludrone > Smart Environmental Monitoring SolutionOizom Polludrone > Smart Environmental Monitoring Solution
Oizom Polludrone > Smart Environmental Monitoring SolutionOizom
 
Instrumentation: Liquid and Gas Sensing (Design Conference 2013)
Instrumentation: Liquid and Gas Sensing (Design Conference 2013)Instrumentation: Liquid and Gas Sensing (Design Conference 2013)
Instrumentation: Liquid and Gas Sensing (Design Conference 2013)Analog Devices, Inc.
 
Rate and Performance Analysis of Indoor Optical Camera Communications in Opti...
Rate and Performance Analysis of Indoor Optical Camera Communications in Opti...Rate and Performance Analysis of Indoor Optical Camera Communications in Opti...
Rate and Performance Analysis of Indoor Optical Camera Communications in Opti...Willy Anugrah Cahyadi
 
Concentration and Size of Viruses and Virus-like Particles
Concentration and Size of Viruses and Virus-like ParticlesConcentration and Size of Viruses and Virus-like Particles
Concentration and Size of Viruses and Virus-like ParticlesHORIBA Particle
 
WIRDfinalposter
WIRDfinalposterWIRDfinalposter
WIRDfinalposterErik Zaro
 
/conferences/spr2002/presentations/ssimmons/simmons.ppt
/conferences/spr2002/presentations/ssimmons/simmons.ppt/conferences/spr2002/presentations/ssimmons/simmons.ppt
/conferences/spr2002/presentations/ssimmons/simmons.pptVideoguy
 
Sigfox Makers Tour São Paulo
Sigfox Makers Tour São PauloSigfox Makers Tour São Paulo
Sigfox Makers Tour São PauloNicolas Lesconnec
 

Similaire à Smoke sentry 2_pdr_presentation (20)

Digital Detectors for Industrial Applications-Nityanand Gopalika
Digital Detectors for Industrial Applications-Nityanand GopalikaDigital Detectors for Industrial Applications-Nityanand Gopalika
Digital Detectors for Industrial Applications-Nityanand Gopalika
 
IGERTSummary
IGERTSummaryIGERTSummary
IGERTSummary
 
Sigfox Makers Tour - Mexico City
Sigfox Makers Tour - Mexico CitySigfox Makers Tour - Mexico City
Sigfox Makers Tour - Mexico City
 
Sci 680 smart air quality sensor
Sci 680 smart air quality sensorSci 680 smart air quality sensor
Sci 680 smart air quality sensor
 
Track 2 session 4 - st dev con 2016 - opensoftwarex
Track 2   session 4 - st dev con 2016 - opensoftwarexTrack 2   session 4 - st dev con 2016 - opensoftwarex
Track 2 session 4 - st dev con 2016 - opensoftwarex
 
Innovate in new and exciting optical sensing applications in industrial marke...
Innovate in new and exciting optical sensing applications in industrial marke...Innovate in new and exciting optical sensing applications in industrial marke...
Innovate in new and exciting optical sensing applications in industrial marke...
 
intelligent_sensing_for_environmental_&_process_measurement_ppt_ADI.pdf
intelligent_sensing_for_environmental_&_process_measurement_ppt_ADI.pdfintelligent_sensing_for_environmental_&_process_measurement_ppt_ADI.pdf
intelligent_sensing_for_environmental_&_process_measurement_ppt_ADI.pdf
 
Photonics as enabling technology in the Security and Defense sectors
Photonics as enabling technology in the Security and Defense sectorsPhotonics as enabling technology in the Security and Defense sectors
Photonics as enabling technology in the Security and Defense sectors
 
Presentation03 27 03
Presentation03 27 03Presentation03 27 03
Presentation03 27 03
 
Oizom Polludrone > Smart Environmental Monitoring Solution
Oizom Polludrone > Smart Environmental Monitoring SolutionOizom Polludrone > Smart Environmental Monitoring Solution
Oizom Polludrone > Smart Environmental Monitoring Solution
 
Instrumentation: Liquid and Gas Sensing (Design Conference 2013)
Instrumentation: Liquid and Gas Sensing (Design Conference 2013)Instrumentation: Liquid and Gas Sensing (Design Conference 2013)
Instrumentation: Liquid and Gas Sensing (Design Conference 2013)
 
Nano-Spectrophotometer
Nano-SpectrophotometerNano-Spectrophotometer
Nano-Spectrophotometer
 
Rate and Performance Analysis of Indoor Optical Camera Communications in Opti...
Rate and Performance Analysis of Indoor Optical Camera Communications in Opti...Rate and Performance Analysis of Indoor Optical Camera Communications in Opti...
Rate and Performance Analysis of Indoor Optical Camera Communications in Opti...
 
Concentration and Size of Viruses and Virus-like Particles
Concentration and Size of Viruses and Virus-like ParticlesConcentration and Size of Viruses and Virus-like Particles
Concentration and Size of Viruses and Virus-like Particles
 
WIRDfinalposter
WIRDfinalposterWIRDfinalposter
WIRDfinalposter
 
Tru Process
Tru ProcessTru Process
Tru Process
 
Spectroradiometer
SpectroradiometerSpectroradiometer
Spectroradiometer
 
/conferences/spr2002/presentations/ssimmons/simmons.ppt
/conferences/spr2002/presentations/ssimmons/simmons.ppt/conferences/spr2002/presentations/ssimmons/simmons.ppt
/conferences/spr2002/presentations/ssimmons/simmons.ppt
 
Sensors for detection
Sensors for detectionSensors for detection
Sensors for detection
 
Sigfox Makers Tour São Paulo
Sigfox Makers Tour São PauloSigfox Makers Tour São Paulo
Sigfox Makers Tour São Paulo
 

Dernier

Pharmaceutical Marketting: Unit-5, Pricing
Pharmaceutical Marketting: Unit-5, PricingPharmaceutical Marketting: Unit-5, Pricing
Pharmaceutical Marketting: Unit-5, PricingArunagarwal328757
 
College Call Girls Vyasarpadi Whatsapp 7001305949 Independent Escort Service
College Call Girls Vyasarpadi Whatsapp 7001305949 Independent Escort ServiceCollege Call Girls Vyasarpadi Whatsapp 7001305949 Independent Escort Service
College Call Girls Vyasarpadi Whatsapp 7001305949 Independent Escort ServiceNehru place Escorts
 
Russian Call Girls Chickpet - 7001305949 Booking and charges genuine rate for...
Russian Call Girls Chickpet - 7001305949 Booking and charges genuine rate for...Russian Call Girls Chickpet - 7001305949 Booking and charges genuine rate for...
Russian Call Girls Chickpet - 7001305949 Booking and charges genuine rate for...narwatsonia7
 
call girls in Connaught Place DELHI 🔝 >༒9540349809 🔝 genuine Escort Service ...
call girls in Connaught Place  DELHI 🔝 >༒9540349809 🔝 genuine Escort Service ...call girls in Connaught Place  DELHI 🔝 >༒9540349809 🔝 genuine Escort Service ...
call girls in Connaught Place DELHI 🔝 >༒9540349809 🔝 genuine Escort Service ...saminamagar
 
Call Girls Thane Just Call 9910780858 Get High Class Call Girls Service
Call Girls Thane Just Call 9910780858 Get High Class Call Girls ServiceCall Girls Thane Just Call 9910780858 Get High Class Call Girls Service
Call Girls Thane Just Call 9910780858 Get High Class Call Girls Servicesonalikaur4
 
Call Girl Bangalore Nandini 7001305949 Independent Escort Service Bangalore
Call Girl Bangalore Nandini 7001305949 Independent Escort Service BangaloreCall Girl Bangalore Nandini 7001305949 Independent Escort Service Bangalore
Call Girl Bangalore Nandini 7001305949 Independent Escort Service Bangalorenarwatsonia7
 
Call Girls Service in Bommanahalli - 7001305949 with real photos and phone nu...
Call Girls Service in Bommanahalli - 7001305949 with real photos and phone nu...Call Girls Service in Bommanahalli - 7001305949 with real photos and phone nu...
Call Girls Service in Bommanahalli - 7001305949 with real photos and phone nu...narwatsonia7
 
Hematology and Immunology - Leukocytes Functions
Hematology and Immunology - Leukocytes FunctionsHematology and Immunology - Leukocytes Functions
Hematology and Immunology - Leukocytes FunctionsMedicoseAcademics
 
call girls in green park DELHI 🔝 >༒9540349809 🔝 genuine Escort Service 🔝✔️✔️
call girls in green park  DELHI 🔝 >༒9540349809 🔝 genuine Escort Service 🔝✔️✔️call girls in green park  DELHI 🔝 >༒9540349809 🔝 genuine Escort Service 🔝✔️✔️
call girls in green park DELHI 🔝 >༒9540349809 🔝 genuine Escort Service 🔝✔️✔️saminamagar
 
Call Girls Service Chennai Jiya 7001305949 Independent Escort Service Chennai
Call Girls Service Chennai Jiya 7001305949 Independent Escort Service ChennaiCall Girls Service Chennai Jiya 7001305949 Independent Escort Service Chennai
Call Girls Service Chennai Jiya 7001305949 Independent Escort Service ChennaiNehru place Escorts
 
Call Girls Viman Nagar 7001305949 All Area Service COD available Any Time
Call Girls Viman Nagar 7001305949 All Area Service COD available Any TimeCall Girls Viman Nagar 7001305949 All Area Service COD available Any Time
Call Girls Viman Nagar 7001305949 All Area Service COD available Any Timevijaych2041
 
Glomerular Filtration rate and its determinants.pptx
Glomerular Filtration rate and its determinants.pptxGlomerular Filtration rate and its determinants.pptx
Glomerular Filtration rate and its determinants.pptxDr.Nusrat Tariq
 
VIP Call Girls Mumbai Arpita 9910780858 Independent Escort Service Mumbai
VIP Call Girls Mumbai Arpita 9910780858 Independent Escort Service MumbaiVIP Call Girls Mumbai Arpita 9910780858 Independent Escort Service Mumbai
VIP Call Girls Mumbai Arpita 9910780858 Independent Escort Service Mumbaisonalikaur4
 
Russian Call Girl Brookfield - 7001305949 Escorts Service 50% Off with Cash O...
Russian Call Girl Brookfield - 7001305949 Escorts Service 50% Off with Cash O...Russian Call Girl Brookfield - 7001305949 Escorts Service 50% Off with Cash O...
Russian Call Girl Brookfield - 7001305949 Escorts Service 50% Off with Cash O...narwatsonia7
 
Hemostasis Physiology and Clinical correlations by Dr Faiza.pdf
Hemostasis Physiology and Clinical correlations by Dr Faiza.pdfHemostasis Physiology and Clinical correlations by Dr Faiza.pdf
Hemostasis Physiology and Clinical correlations by Dr Faiza.pdfMedicoseAcademics
 
Call Girls Whitefield Just Call 7001305949 Top Class Call Girl Service Available
Call Girls Whitefield Just Call 7001305949 Top Class Call Girl Service AvailableCall Girls Whitefield Just Call 7001305949 Top Class Call Girl Service Available
Call Girls Whitefield Just Call 7001305949 Top Class Call Girl Service Availablenarwatsonia7
 
Call Girls Electronic City Just Call 7001305949 Top Class Call Girl Service A...
Call Girls Electronic City Just Call 7001305949 Top Class Call Girl Service A...Call Girls Electronic City Just Call 7001305949 Top Class Call Girl Service A...
Call Girls Electronic City Just Call 7001305949 Top Class Call Girl Service A...narwatsonia7
 
Kolkata Call Girls Services 9907093804 @24x7 High Class Babes Here Call Now
Kolkata Call Girls Services 9907093804 @24x7 High Class Babes Here Call NowKolkata Call Girls Services 9907093804 @24x7 High Class Babes Here Call Now
Kolkata Call Girls Services 9907093804 @24x7 High Class Babes Here Call NowNehru place Escorts
 
Book Call Girls in Kasavanahalli - 7001305949 with real photos and phone numbers
Book Call Girls in Kasavanahalli - 7001305949 with real photos and phone numbersBook Call Girls in Kasavanahalli - 7001305949 with real photos and phone numbers
Book Call Girls in Kasavanahalli - 7001305949 with real photos and phone numbersnarwatsonia7
 
Housewife Call Girls Hsr Layout - Call 7001305949 Rs-3500 with A/C Room Cash ...
Housewife Call Girls Hsr Layout - Call 7001305949 Rs-3500 with A/C Room Cash ...Housewife Call Girls Hsr Layout - Call 7001305949 Rs-3500 with A/C Room Cash ...
Housewife Call Girls Hsr Layout - Call 7001305949 Rs-3500 with A/C Room Cash ...narwatsonia7
 

Dernier (20)

Pharmaceutical Marketting: Unit-5, Pricing
Pharmaceutical Marketting: Unit-5, PricingPharmaceutical Marketting: Unit-5, Pricing
Pharmaceutical Marketting: Unit-5, Pricing
 
College Call Girls Vyasarpadi Whatsapp 7001305949 Independent Escort Service
College Call Girls Vyasarpadi Whatsapp 7001305949 Independent Escort ServiceCollege Call Girls Vyasarpadi Whatsapp 7001305949 Independent Escort Service
College Call Girls Vyasarpadi Whatsapp 7001305949 Independent Escort Service
 
Russian Call Girls Chickpet - 7001305949 Booking and charges genuine rate for...
Russian Call Girls Chickpet - 7001305949 Booking and charges genuine rate for...Russian Call Girls Chickpet - 7001305949 Booking and charges genuine rate for...
Russian Call Girls Chickpet - 7001305949 Booking and charges genuine rate for...
 
call girls in Connaught Place DELHI 🔝 >༒9540349809 🔝 genuine Escort Service ...
call girls in Connaught Place  DELHI 🔝 >༒9540349809 🔝 genuine Escort Service ...call girls in Connaught Place  DELHI 🔝 >༒9540349809 🔝 genuine Escort Service ...
call girls in Connaught Place DELHI 🔝 >༒9540349809 🔝 genuine Escort Service ...
 
Call Girls Thane Just Call 9910780858 Get High Class Call Girls Service
Call Girls Thane Just Call 9910780858 Get High Class Call Girls ServiceCall Girls Thane Just Call 9910780858 Get High Class Call Girls Service
Call Girls Thane Just Call 9910780858 Get High Class Call Girls Service
 
Call Girl Bangalore Nandini 7001305949 Independent Escort Service Bangalore
Call Girl Bangalore Nandini 7001305949 Independent Escort Service BangaloreCall Girl Bangalore Nandini 7001305949 Independent Escort Service Bangalore
Call Girl Bangalore Nandini 7001305949 Independent Escort Service Bangalore
 
Call Girls Service in Bommanahalli - 7001305949 with real photos and phone nu...
Call Girls Service in Bommanahalli - 7001305949 with real photos and phone nu...Call Girls Service in Bommanahalli - 7001305949 with real photos and phone nu...
Call Girls Service in Bommanahalli - 7001305949 with real photos and phone nu...
 
Hematology and Immunology - Leukocytes Functions
Hematology and Immunology - Leukocytes FunctionsHematology and Immunology - Leukocytes Functions
Hematology and Immunology - Leukocytes Functions
 
call girls in green park DELHI 🔝 >༒9540349809 🔝 genuine Escort Service 🔝✔️✔️
call girls in green park  DELHI 🔝 >༒9540349809 🔝 genuine Escort Service 🔝✔️✔️call girls in green park  DELHI 🔝 >༒9540349809 🔝 genuine Escort Service 🔝✔️✔️
call girls in green park DELHI 🔝 >༒9540349809 🔝 genuine Escort Service 🔝✔️✔️
 
Call Girls Service Chennai Jiya 7001305949 Independent Escort Service Chennai
Call Girls Service Chennai Jiya 7001305949 Independent Escort Service ChennaiCall Girls Service Chennai Jiya 7001305949 Independent Escort Service Chennai
Call Girls Service Chennai Jiya 7001305949 Independent Escort Service Chennai
 
Call Girls Viman Nagar 7001305949 All Area Service COD available Any Time
Call Girls Viman Nagar 7001305949 All Area Service COD available Any TimeCall Girls Viman Nagar 7001305949 All Area Service COD available Any Time
Call Girls Viman Nagar 7001305949 All Area Service COD available Any Time
 
Glomerular Filtration rate and its determinants.pptx
Glomerular Filtration rate and its determinants.pptxGlomerular Filtration rate and its determinants.pptx
Glomerular Filtration rate and its determinants.pptx
 
VIP Call Girls Mumbai Arpita 9910780858 Independent Escort Service Mumbai
VIP Call Girls Mumbai Arpita 9910780858 Independent Escort Service MumbaiVIP Call Girls Mumbai Arpita 9910780858 Independent Escort Service Mumbai
VIP Call Girls Mumbai Arpita 9910780858 Independent Escort Service Mumbai
 
Russian Call Girl Brookfield - 7001305949 Escorts Service 50% Off with Cash O...
Russian Call Girl Brookfield - 7001305949 Escorts Service 50% Off with Cash O...Russian Call Girl Brookfield - 7001305949 Escorts Service 50% Off with Cash O...
Russian Call Girl Brookfield - 7001305949 Escorts Service 50% Off with Cash O...
 
Hemostasis Physiology and Clinical correlations by Dr Faiza.pdf
Hemostasis Physiology and Clinical correlations by Dr Faiza.pdfHemostasis Physiology and Clinical correlations by Dr Faiza.pdf
Hemostasis Physiology and Clinical correlations by Dr Faiza.pdf
 
Call Girls Whitefield Just Call 7001305949 Top Class Call Girl Service Available
Call Girls Whitefield Just Call 7001305949 Top Class Call Girl Service AvailableCall Girls Whitefield Just Call 7001305949 Top Class Call Girl Service Available
Call Girls Whitefield Just Call 7001305949 Top Class Call Girl Service Available
 
Call Girls Electronic City Just Call 7001305949 Top Class Call Girl Service A...
Call Girls Electronic City Just Call 7001305949 Top Class Call Girl Service A...Call Girls Electronic City Just Call 7001305949 Top Class Call Girl Service A...
Call Girls Electronic City Just Call 7001305949 Top Class Call Girl Service A...
 
Kolkata Call Girls Services 9907093804 @24x7 High Class Babes Here Call Now
Kolkata Call Girls Services 9907093804 @24x7 High Class Babes Here Call NowKolkata Call Girls Services 9907093804 @24x7 High Class Babes Here Call Now
Kolkata Call Girls Services 9907093804 @24x7 High Class Babes Here Call Now
 
Book Call Girls in Kasavanahalli - 7001305949 with real photos and phone numbers
Book Call Girls in Kasavanahalli - 7001305949 with real photos and phone numbersBook Call Girls in Kasavanahalli - 7001305949 with real photos and phone numbers
Book Call Girls in Kasavanahalli - 7001305949 with real photos and phone numbers
 
Housewife Call Girls Hsr Layout - Call 7001305949 Rs-3500 with A/C Room Cash ...
Housewife Call Girls Hsr Layout - Call 7001305949 Rs-3500 with A/C Room Cash ...Housewife Call Girls Hsr Layout - Call 7001305949 Rs-3500 with A/C Room Cash ...
Housewife Call Girls Hsr Layout - Call 7001305949 Rs-3500 with A/C Room Cash ...
 

Smoke sentry 2_pdr_presentation

  • 1. Preliminary Design Review Senior Design Clinic Team 10
  • 2. Team Members and Roles  Core Team:  Jeff Frank (EE) – Team Lead  Kelvin Kosbab (EE)  Tim Nguyen (EE)  Mike Masek (ME)  Advisor: Ramesh Rajagopalan  Observers:  Chris Engelmann (Sponsor)  Kevin Nicholson (Engineering Coordinator) 2
  • 3. Background  Smoke from fires and cigarettes differs greatly  Cigarette smoke particles: ○ Considerably smaller ○ Reduced particle concentration  Commercial smoke detectors are designed for fires ○ Insensitive to cigarette smoke 3
  • 4. Problem Statement  Very challenging for hotels to enforce no smoking policies  Some guests are sensitive to smoke residue ○ Discomfort ○ Health issues ○ Unpleasant odors  Smoke damage can result in thousands of dollars in repair costs  Customer needs system capable of notifying hotel staff of smoking violations 4
  • 6. Statement of Work  Deliverables:  Research documentation  Design documentation  Prototype of a cigarette smoke monitoring system  Test specifications  Data supporting a prototype functioning within specifications 6
  • 7. Customer Requirements  Cost target:  Detection Unit: < $50  Monitoring Station: < $1,500  Size target: < twice fire smoke detectors  smaller than 8.5” x 8.5” x 3”  Improved sensitivity over existing detectors  Network capable of 100 room hotel  Functional under US regulations 7
  • 8. Requirements Validation Functional Requirement Validation  Capable of detecting  Establish controlled tests cigarette smoke  Record conditions  Minimize false positives  Run in controlled setting  < 2 per hotel  Count total false positives  Latency  Measure using  Network: < 20 seconds timestamp  Detection: < 5 minutes  Testing in similar room 8
  • 9. What is Smoke?  Gases  Carbon monoxide, nitrogen oxide  Chemicals  Formeldehyde, acrolene, benzene  Particulates  Nicotene, phenol, polyaromatic hydrocarbons  Size: 100 – 4,000 nm http://www.engineeringtoolbox.com/particle-sizes-d_934.html http://cancercontrol.cancer.gov/tcrb/monographs/7/m7_5.pdf 9
  • 10. Work Breakdown Structure  Design choices have little effect on each other 12
  • 11. Smoke Detection Type of Obscuration Level Particle Sensitivity Range Detector (% obs/m) (nm) Ionization 2.6 – 5.0 10 - 300 Photoelectric 6.5 – 13.0 300 – 10,000 Laser 0.06 – 6.41 N/A  Cigarette smoke (average): 100 nm – 300 nm  Goal: optimize laser technique  Increase sensitivity ○ Obscuration ○ Particle size  Minimize false positives 14
  • 12. Ionization Method Smoke Absent Smoke Present http://www.epa.gov/radiation/sources/smoke_ion.html 15
  • 13. Ionization Design Tweaks  Dual chamber sensor  Rejects fluctuations in humidity and atmospheric pressure  Increase current between plates  Larger voltage  Minimize distance 16
  • 14. Implementation Difficulties  Measuring pico-Amps  Design and construction of ionization chamber  Radioactive material 17
  • 15. Photoelectric Method Smoke Absent Smoke Present 18
  • 16. Optimization Design Tweaks  Laser Diode  Much brighter than LED  635 nm  Photo-sensor array  Minimize ambient light 19
  • 17. Optimization Design Tweaks  Optical techniques  Mirrors  Lens  Filters 20
  • 18. Optimization Design Tweaks  Lock-in Amplifier  Laser  sine wave  Photosensor  sine wave  Noise rejection  All frequencies components not equal to sine wave attenuated ○ Ambient light ○ High frequency transients 21
  • 19. General Techniques  Optimize airflow into smoke chamber  Concentrate airflow to one area  Laser beam path  Algorithm rejects dust detection 23
  • 20. Flame Detection  UV and IR detection in combination  Used as a secondary sensor  Applied as an aid for primary sensor  Increase sampling rate of Photoelectric sensor  Send notification to front desk 24
  • 21. Sensor Nodes: Microprocessor  Requirements on microprocessor not demanding  Choose a PIC from Microchip ○ Many microprocessors available  Choose the smallest, cheapest one with enough I/O and peripherals  Requires SPI, timer, sufficient I/O pins 25
  • 22. Wireless Network  Transmitted Data  Smoke status  Flame status  Room #  Time Stamp 26
  • 23. Wireless Network Protocol  IEEE 802.15.4  Low data rate, Personal Area Networks ○ Zigbee ○ MiWi  2.4 GHz – International ○ 250 Kbit/s ○ Shorter range  915 MHz – North America ○ 40 Kbit/s ○ Longer range 27
  • 24. MiWi  Less complex implementation of ZigBee  Shorter development time ○ MiWi Development Studio ○ ZENA  MiWi standardizes…  Network protocol ○ Software package  Transceivers  Hotel room capability: 8,128  Mesh routing 28
  • 25. Monitoring Station  Application run on Windows 7 laptop  USB connected MiWi transceiver (ZENA)  Option 1: LabVIEW  Pros: Easiest to implement, most of the programming already done  Cons: License fee, not as flexible, limited hardware options (NI hardware only) http://labviewwiki.org/images/thumb/3/32/LabVIEW_Logo_Vertical_4c.jpg/200px- LabVIEW_Logo_Vertical_4c.jpg 31
  • 26. Monitoring Station  Option 2: Java application  Communication with ZENA via C commands and system commands  Pros: Free, flexible, easy to implement, more control, experience in Java programming  Cons: more coding, more testing http://www.digitaltrends.com/computing/most-vulnerable-browser-plugin-think-java-not-flash/ 32
  • 27. Design Summary  Cigarette Detection  Smoke detection – Laser (Photoelectric)  Flame detection – UV & IR  Wireless Network  MiWi  Monitoring Station  Java  ZENA 35
  • 29. Budget  Total Allocated Budget = $2,500 ○ Cigarette Detection  $200 ○ Wireless Network  $500 ○ PCB & Housing  $400 ○ Miscellaneous Prototyping  $300  Estimated Cost: $1,400 38

Notes de l'éditeur

  1. To begin we’d like to give some background on the state of the problem. Firstly, fire smoke and cigarette smoke are much different. Particles from cigarette smoke are much smaller and have a much smaller particle concentration. Second, detectors used commercially are designed for fires, and are therefore insensitive to smoke from cigarettes.
  2. We were approached with a problem from hotel management. Non-smoking rooms were being damaged because of use of cigarettes and possibly other substances within the designated no smoking facilities. This causes future guests discomfort and possible health issues. It also causes hotel repair costs and their reputation to be affected. The customer needs a way to help enforce no smoking policies as well as catch those who break it before damage has been done. Specify as customer problem statement
  3. This is a block diagram of the cigarette monitoring system, it consists of smoke detection units installed in hotel rooms and a computer at the hotel’s front desk which monitors the rooms. The smoke detection unit will contain a pair of sensors, a microprocessor, and a transmitter receiver for wireless communication with monitoring station. We plan on building 1 smoke detection unit, 1 monitoring station, and 4-5 relay nodes. The relay nodes will be capable of wireless communication but not cigarette detection. They will be used to test the network functionality more rigorously.
  4. By April, we plan to be able to deliver a bundle of our work. This will include documentation of our preliminary research and design ideas, our working smoke sensor, descriptions of our testing, and resulting information to show our model works under sponsor/user specifications.
  5. Here are the requirements that were given to us by our customer along with the methods that we will use to validate that we met that requirement. First is a cost requirement for the system. Each sensor node in each room is required to be less than $50. In the lobby, the monitoring station is to be less than $1500. Next our customer required us to design a sensor that is less than twice the size of a commercial smoke sensor. This value comes out to be about 8.5x8.5x3 inches. We are required to develop a system with greater sensitivity over commercial smoke detectors. The network capacity for our project is required to support at least 100 rooms. We will insure that multiple devices can communicate with the lobby’s monitoring station. Our project will have to be functional under US regulations so it can be used in the US. Therefore, we will abide by the standards and regulations already established by the government.
  6. To determine the effectiveness of our system, we will set up a variety of controlled tests. These tests will determine the capability of our system in terms of smoke detection. We want to limit the amount of false positives to less than 5 per day per room. Again, we will set up controlled test for verification.A latency of 20 seconds is the max latency for the network, which is the time it takes a sensor to communicate with the lobby’s monitoring station. To test this we will establish tests to measure the time it takes for a message to be sent from the sensor. The detection latency is the time it takes the sensor to send an alarm message after a cigarette has been lit. This is required to be less than 5 minutes. For validation, we will set up controlled tests in rooms that have similar characteristics as hotel rooms to determine how long it takes for an alarm to be set off.
  7. So what exactly is cigarette smoke? As you can see, it consists of three different groups: gases, chemicals, and particulates. For our purposes, we are attempting to sense the presence of particulates, as they are the most prevalent and detectable in the smoke.
  8. Here is a breakdown of our project. We realized that there were 3 major components to the system, each of which are more or less mutually exclusive from each other, so one component is not necessarily dependent on another component until the final product is to be assembled. The first component is cigarette detection, which includes both smoke detection and flame detection, both of which we will go into greater detail soon. The second component is the wireless network, which includes how the sensor nodes in the rooms are to communicate with the monitoring station at the front desk. The last component is the monitoring station, which consists of the device at the front desk of the hotel that will signal the managers and workers of a smoking alarm.
  9. We will now compare the performance of existing smoke detection techniques. On the left most column of the chart are the two most common methods of smoke detection, Ionization and Photoelectric, and Laser which is a special case of photoelectric. We will be proposing to use a laser type detector in our design. The center column shows their sensitivity in regards to obscuration level. Obscuration measures smoke concentration, so the higher the obscuration, the more smoke there is. So in general, Ionization detectors are better than photoelectric when small amounts of smoke are present. However, several companies have implemented photoelectric sensors using lasers and these have been very sensitive to small amounts of smoke. The next column shows the range of particle sizes which the detectors are most reactive to. The range for ionization detectors fit well for the average size of cigarette smoke particles while the lower range of photoelectric detectors is very near cigarette particles. Unfortunately we could not find data on Laser type detectors but we hope to show that the range for our proposed design will be lower than photoelectric. Overall, our design aims to optimize the laser technique to increase sensitivity in terms of detecting small amounts of smoke as well as the size of smoke particles. Minimizing false positives will also be important to our design.Ionization and Photoelectric are the most common fire smoke detectorsObscuration: measures concentration of smoke (higher obscuration  more smoke)These are the size of the particles which the detection method is most sensitive toLaser is a special case of photoelectricwe are going to choose laserLaser has smaller particle range than photoelectricOptimize for lowest obscuration possible and particle size of cigarette smoke
  10. Images are of a basic ionization chamber. Radioactive material, in this case Americium, is used to create alpha particles. These particles react with the oxygen and other gases in the air to create ions. Two charged plates are closely separated. The charged ions create a current between the two plates, on the order of picoamps. The introduction of smoke particles de-ionizes the air particles and causes the current seen between the plates to decrease. By monitoring the change in current, the sensor is able to detect particles in the air.
  11. Dual Chamber sensor: helps to eliminate effects from humidity and atmospheric pressure on the sensor’s readings. One chamber is the sensing chamber (open to outside world – affected by particles in the air, humidity, and atmospheric pressure), while the other chamber is the reference chamber (partially closed to the outside world – affected by humidity and atmospheric pressure). Electronics measure difference between two chambers. Any change will be only due to particulate matter and not humidity or atmospheric pressureLarger voltage on plates: maximize current -&gt; easier to detect differenceMinimize distance between pates -&gt; maximize current
  12. Mention that because of these reasons we will not be doing IonizationMeasuringpicoamps is difficult to do accurately. Amplifier circuits may be used to step up the current, but it would also step up any noise induced in the system, such as EMI from the network radio. Gathering and using radioactive material is not only dangerous, but also difficult to get proper certification. The plates need to close together, causing difficulties in the construction of the chamber.
  13. This shows the principle of operation of a photoelectric type detector. It typically consists of an infrared LED and a photosensor which are placed off axis. In the absence of smoke, the light from the LED will not reach the photosensor. When smoke particles enter the path of the light, they will randomly scatter the light and the photosensor detects this scattered light.The light source and photosensor are off-axis, without smoke no light reaches the photosensorWhen smoke enters the light’s path, light will scatter randomly and some light reaches the photosensor
  14. Now we’ll discuss how we will improve on the existing technique. In order to increase sensitivity we will use a laser diode rather than an LED. Laser diodes are generally thousands of times brighter than LED’s. So, by increasing the amount of light we emit, more light will be available to be scattered. In addition, while fire smoke detectors use infrared LED’s with a wavelength of 850 nm, we plan on using a red laser with a wavelength of 635 nm. Recall that cigarette particles are 100-300 nm on average. By using a wavelength closer to this range, more light will be scattered. We also plan to use an array of 4-5 photosensors rather than one so that the sensor can capture more of the scattered light. However, the ambient light within the room could be sensed by the photosensors. So, the housing of the whole unit will need to minimize ambient light reaching the photosensors in order to avoid false positives.Laser Diode – commercial detectors use IR (850 nm) LED’s ; mention pinnacle’s claim of making a LASER detector better than ionization - laser = more light to be scattered (even small amount of smoke results in significant scattered light) - lower wavelength = more scattered light - 635, 650 nmPhoto-sensor array: “catch” more scattered light -use large active area sensors Minimize ambient light – with housing design
  15. Although the photosensor array captures more light, much of the light would be scattered away from the sensors. So, our design has a mirror in that region to redirect the scattered light towards the sensors. Also, if we place a lens in front of the laser the volume of the light beam will grow, increasing the probability of smoke particles entering the beam path. Finally, the design will have an optical filter placed in front of the photosensors which only passes light near 635 nm. This will minimize the ambient light reaching the sensor and therefore minimize false positives. Mirrors: redirects scattered light toward photosensor arrayFilter: remove all spectrum components except laser’s (minimizes false positives)Lens: increases effective area of laser beam (i.e. more likely to hit smoke)
  16. The final design tweak is a Lock-in Amplifier which is a general technique used to extract signals from a noisy environment when the expected frequency of the signal is known. Rather than using a DC signal to drive the light source as fire smoke detectors do, a sine wave is used. So, in the presence of smoke, the photosensor would also have a sinusoidal signal. The lock-in amplifier then compares these two sine waves and will amplify only the portion of the photosensors signal which matches the frequency of the laser’s driving signal. So for example, the ambient light in the room will essentially be a DC signal and because it’s frequency does not match the frequency of the laser’s sine wave, the lock-in amplifier will block this part of the signal. Another example would be a light being turned on, which would be a very high frequency event and so it too would not affect the sensor. Laser: sine wave instead of DC, photosensors signal will also be sinusoidallock-in amplifier attenuates any part of the signal with a frequency other than the sine wave which drives the laserAmbient light is essentially DCTurning a light on is very high frequency and random noise will likely be some other frequency
  17. There are several ways in which we can optimize this sensor to work effectively sensing cigarette smoke and to eliminate false positives:Design the sensor’s housing to allow more airflow to the sensing chamberConcentrate the airflow directly to the laser beamUse software to reject anomalies (dust detection, etc.)This will go a long way to reject false positives from our primary sensor.
  18. I say primary sensor, because we will be using our photoelectric detection alongside another secondary sensor. As a secondary sensor, we will use UV and IR detection in combination to detect the lighting of a match or lighter. This will not directly show that smoking is going on, but will serve as a flag to the monitoring station. When this occurs, the sampling rate of our primary sensor will increase. By using this we hope to further reject the occurrence of false positives. (Note that sampling of the primary sensor INCREASES; this sensor is used as a support system, and both primary and secondary sensors run simultaneously.)
  19. The second component of our project is the wireless network. The data that will need to be communicated over the network includes the smoke status of the room, the flame status of the room, the room number associated with the sensor, and a time stamp. We will focus on using a low data rate in order to ease the capabilities on our network.
  20. Say why we didn’t choose ZigBee here (interoperability, cost, lack of ease)Data bandwidth implies we will meet network latency requirementFrequencies meets sell-able in US requirementDon’t say these:2.4 GHz – smaller antenna915 MHz – larger antennaMultiplexing: DSSS, FHSS, OFDMModulation: FSK, OOK
  21. MiWi is a proprietary wireless network protocol from Microchip which was designed to have the same functionality as Zigbee and yet be easier to develop and use. This is beneficial for us since we’ll be able to devote more time to working on smoke detection. One way they’ve made the development process easier is by providing software to assist in the network’s configuration as well as debugging and analysis. They also sell a product called ZENA, shown here, which allows a computer to monitor data transmission within the network. You can also enable a computer to be an actual node in the network. So, we will use ZENA to enable the computer at the front desk to receive data from the smoke detection units. In general, there are two ways Microchip defines its network protocol. First, it provides a software package which is combined with the application firmware we will write. This provides the microprocessor the ability to perform network functions. Microchip also specially designs transmitter receivers to be compatible with MiWi. In addition, MiWi networks have a maximum of a little over 8,000 network nodes, which easily meets our requirement of a 100 room hotel. Additionally, MiWi provides automatic mesh routing. This means that data will always take the shortest route to its destination and if that path is broken, it will automatically find a new path. This feature is great since it will minimize network latency.- Shorter develpoment time: We can focus on smoke detectionMiWi Development Studio: software suite enables easier developmentZena: network analysis tool monitors data traveling on the network, can also connect a laptop to the network (monitoring station)Software package: loaded onto microprocessor, automates networking operationsTransceivers: hardware RF transceiversRoom capacity meets customer requirementsMesh routing: finds shortest path to destination, reconfigures path if path is brokenMeets network latency requirement
  22. Capable of 100 room hotelMemory footprint – coordinator (25 KB) end device (16 KB) - ZigBee: coordinator (100 KB) end device (40 KB)
  23. Special Functionality – noise detection scan (across channels), transceiver sleep/wake,
  24. Note that the laptop solution will easily be &lt; $1,500The final component is the monitoring station, which will be located at the front desk of the hotel. It is here where the staff will be alerted to any smoking violations in any of the rooms. We did some research and the computers at the hotels have their own specific hotel operating system and it would be very difficult installing other programs on these machines. Therefore we decided to buy a cheap laptop that will specifically run our program. As Tim said earlier, ZENA will be used to help monitor the wireless communication packets that are sent through the system. As for the application software itself, there are two options. First is LabVIEW. Most of the details are already programmed into the software and that would help with implementation. The LabVIEW software comes with a fee and also would limit us to National Instruments hardware, which would also increase cost. However the most important downfall of LabVIEW is not many people are familiar with the program and how it functions. We find that user friendliness is extremely important. The worker at the desk should be able to easily navigate and operate the application.
  25. The next interface that is possible is simply developing a Java application. Java provides the ability to control every aspect of our application and is very straightforward in developing GUIs. Netbeans for example has a tool that allows you to develop a GUI without writing any code. All it requires is you to drag buttons and other components where you want them. Although this would require more programming, it would provide much more control both under the application’s “hood” and visually. Because Java provides so much specific control, we could insure that the user’s interface is pleasant and easy to understand and operate.
  26. To summarize, our design consists of three independent components. First, our primary sensor (photoelectric) and secondary sensor (UV/IR) serve to detect the presence of smoke. Second, our wireless network communicates this information quickly and efficiently. Finally, our monitoring station receives the information and informs the attendant through a user-friendly interface.
  27. This is our proposed project schedule. As mentioned earlier, we see this project as having 3 independent stages. By implementing parallel engineering in those 3 stages, we hope to have a working prototype by mid march, giving us over a month to test and fine-tune our design.
  28. Our budget is 2,500 dollars and throughout our research we’ve been considering what we will have to buy and checking prices on those items. Based on that this is how we estimate we will be spending our money with the total being well under budget at 1,400 dollars. This leaves some room for unexpected purchases.