1. Introduction
2. Applications
3. Hearing aid
4. Brain signals – electroencephalogram
5. The acquisition of a blood pressure signal
6. References
 Most natural phenomena occur continuously in time, such as the
variations of temperature of the human body, forces exerted by
muscles, or electrical potentials generated on the surface of the scalp.
 By sampling these analog signal, digital signals are formed.
 Major applications of DSP in the field of medicine are widely applied
in patient monitoring, diagnosis, as well as physiological investigation
and in some therapeutic settings (e.g. Muscle and sensory stimulation,
hearing aids).
 Hearing aid
 Brain signals – electroencephalogram
 The acquisition of a blood pressure signal
 The sound is picked up by the microphone, is converted into an
electric signal, and then digitized.
 The digital signal is then filtered to selectively amplify those
frequency bands in which the patient shows the most severe hearing
loss.
 Amplitude compression, in which the system gain is reduced when
the amplitude exceeds some pre-defined threshold values, in order
to avoid excessive loudness to the ear is also used.
 Finally the processed digital signal is converted back to analog form
in the digital-to-analog (D/A) converter, and delivered to the ear via
the earphone.
In a further stage of signal processing in hearing aids, the amplitude-range
may be compressed. Hence, the gain of the system is progressively reduced
when the sound-volume exceeds a specified level, as is the case near the
end of this recording. A small delay in adapting the gain to the signal-levels
may also be added, as the average of the most recent amplitudes drives the
gain control.
 The two basic, non-invasive, brain signals are the EEG.
 Both find use in routine neuro-physiological evaluation, for e.g. diagnosis
and following the development of brain diseases, and in monitoring
anaesthetised patients during medical operations.
 The EEG is the electrical activity of the brain and may contain diagnostic
information for a variety of neurological conditions, such as sleep disorders,
and coma.
 They are often described by the frequency band in which they lie ( e.g alpha
rhythm, beta activity, delta waves), and by their amplitude, and the pattern
of distribution on the scalp.
4 second excerpt from as EEG
 The characteristics of the EEG vary considerably with the state of the
patient, e.g whether the patient's eyes are open or closed, whether
the patient is drowsy, soundly asleep, asleep and dreaming.
 The EEG lends itself to time and frequency analysis.
Segment of the original EEG signal (solid line), and the same signal
reconstructed from only its DFT components in the α frequency band
(dotted line). The oscillation in the frequency band of 8-13 Hz is
enhanced. The slow change during the artefact in the EEG signal around
29.5 s is eliminated, as are some of the faster variations (higher
frequency beta activity, and noise ) seen in the raw data.
 Spectral estimation: Spectral estimation helps in finding the pulse
rhythms present in the EEG signal. The short segment of EEG data is
analyzed for spectral parameters such as location and amount of
spectral energy. Wave-shaping filters are extensively used in this
technique. Wave shaping filters produce desired output signal for
given input signal.
 ARMA (autoregressive moving average) method: This model is
suggested for modelling signals with sharp peaks and valleys in their
frequency content and also signals with severe background noise.
Frequency response |f(H)| of a second-order Butterworth band-pass
filter, with cut-off frequencies at 8 and 13 Hz. This filter will preserve
activity in the alpha frequency band, while attenuating other frequency
bands.
Using and IIR filter with coefficients a=[1 -7.43 24.44 -46.33 55.38 -42.75
20.82 -5.84 0.72] and b =10-4 [0.12 0 -0.48 0 0.720 -0.48 0 0.12], very rapid
change and slow variations are eliminated, and only the signal
components in the alpha frequency band are maintained.
An IIR filter is used to
enhance the alpha activity in
an EEG signal that contains
mains interference (50 Hz),
and noise.
 A blood pressure (BP) signal contains clinically relevant components
up to about 20 Hz.
 The signal is contaminated by noise at the mains frequency (50 Hz)
and other noise (mainly below 50 Hz) may also be present
 Thus the sampling rate has to be above 100Hz, as the highest
frequency present is 50 Hz.
 If the noise (mains interference) is removed prior to sampling, by a
low-pass (anti-alias) filter with a cut-off frequency at say 20 Hz, the
sampling rate could be reduced to a value above 40 Hz, without
significant aliasing occurring.
The power spectrum of this signal, sampled at 67 Hz. Without the anti-alias filter
(dotted lines), the 50 Hz noise is aliased, and appears as a very large peak at 17 Hz (67-
50 Hz). With the anti-alias filter (solid line), this peak is very much reduced (though not
eliminated, due to the imperfection of the filter), and can be considered insignificant.
 H. Nyquist (1928) Certain Topics in Telegraph Transmission
Theory. Trans. AIEE, vol. 47, pp. 617-644.
 A. Antoniou. (1993) Digital Filters: Analysis, Design and
Applications. New York, NY: McGraw-Hill, 2nd Edition.
 L. B. Jackson. (1996) Digital Filters and Signal Processing. Boston,
MA: Kluwer, 3rd Edition.
 A. V. Oppenheim, and R. W. Schafer (1989). Discrete-Time Signal
Processing. Englewood Cliffs, NJ: Prentice Hall.
 S. K. Mitra. (2001) Digital Signal Processing: A Computer-Based
Approach. New York, NY: McGraw-Hill, 2nd Edition.

More Related Content

What's hot

Power delay profile,delay spread and doppler spread
Power delay profile,delay spread and doppler spreadPower delay profile,delay spread and doppler spread
Power delay profile,delay spread and doppler spread
Manish Srivastava
 
Introduction of digital communication
Introduction of digital communicationIntroduction of digital communication
Introduction of digital communication
asodariyabhavesh
 
Parameters of multipath channel
Parameters of multipath channelParameters of multipath channel
Parameters of multipath channel
Naveen Kumar
 
PSK (PHASE SHIFT KEYING )
PSK (PHASE SHIFT KEYING )PSK (PHASE SHIFT KEYING )
PSK (PHASE SHIFT KEYING )
vijidhivi
 

What's hot (20)

PULSE CODE MODULATION (PCM)
PULSE CODE MODULATION (PCM)PULSE CODE MODULATION (PCM)
PULSE CODE MODULATION (PCM)
 
Digital modulation techniques...
Digital modulation techniques...Digital modulation techniques...
Digital modulation techniques...
 
Quadrature amplitude modulation
Quadrature amplitude modulationQuadrature amplitude modulation
Quadrature amplitude modulation
 
Orthogonal Frequency Division Multiplexing (OFDM)
Orthogonal Frequency Division Multiplexing (OFDM)Orthogonal Frequency Division Multiplexing (OFDM)
Orthogonal Frequency Division Multiplexing (OFDM)
 
Equalization
EqualizationEqualization
Equalization
 
SPEECH CODING
SPEECH CODINGSPEECH CODING
SPEECH CODING
 
Power delay profile,delay spread and doppler spread
Power delay profile,delay spread and doppler spreadPower delay profile,delay spread and doppler spread
Power delay profile,delay spread and doppler spread
 
Introduction of digital communication
Introduction of digital communicationIntroduction of digital communication
Introduction of digital communication
 
Linear Predictive Coding
Linear Predictive CodingLinear Predictive Coding
Linear Predictive Coding
 
Introduction to dsp
Introduction to dspIntroduction to dsp
Introduction to dsp
 
Parameters of multipath channel
Parameters of multipath channelParameters of multipath channel
Parameters of multipath channel
 
Fm transmitter and receivers
Fm transmitter and receiversFm transmitter and receivers
Fm transmitter and receivers
 
FILTER BANKS
FILTER BANKSFILTER BANKS
FILTER BANKS
 
PSK (PHASE SHIFT KEYING )
PSK (PHASE SHIFT KEYING )PSK (PHASE SHIFT KEYING )
PSK (PHASE SHIFT KEYING )
 
Adaptive equalization
Adaptive equalizationAdaptive equalization
Adaptive equalization
 
orthogonal frequency division multiplexing(OFDM)
orthogonal frequency division multiplexing(OFDM)orthogonal frequency division multiplexing(OFDM)
orthogonal frequency division multiplexing(OFDM)
 
Signal and System, CT Signal DT Signal, Signal Processing(amplitude and time ...
Signal and System, CT Signal DT Signal, Signal Processing(amplitude and time ...Signal and System, CT Signal DT Signal, Signal Processing(amplitude and time ...
Signal and System, CT Signal DT Signal, Signal Processing(amplitude and time ...
 
Optical recording(39,38,29)
Optical recording(39,38,29)Optical recording(39,38,29)
Optical recording(39,38,29)
 
Basics of Digital Filters
Basics of Digital FiltersBasics of Digital Filters
Basics of Digital Filters
 
Filter- IIR - Digital signal processing(DSP)
Filter- IIR - Digital signal processing(DSP)Filter- IIR - Digital signal processing(DSP)
Filter- IIR - Digital signal processing(DSP)
 

Similar to Medical applications of dsp

Sampling tutorial
Sampling tutorialSampling tutorial
Sampling tutorial
Cut Lilis
 
BERA AND otoacoustic emission edited.pptx
BERA AND  otoacoustic emission edited.pptxBERA AND  otoacoustic emission edited.pptx
BERA AND otoacoustic emission edited.pptx
Manu Babu
 
Sleep 2008 Electronicsv.3
Sleep 2008 Electronicsv.3Sleep 2008 Electronicsv.3
Sleep 2008 Electronicsv.3
weckhardt
 

Similar to Medical applications of dsp (20)

Medical dsp
Medical dsp Medical dsp
Medical dsp
 
Neural signal processing by mustafa rasheed & zeena saadon & walaa kahtan 2015
Neural signal processing by mustafa rasheed & zeena saadon & walaa kahtan 2015Neural signal processing by mustafa rasheed & zeena saadon & walaa kahtan 2015
Neural signal processing by mustafa rasheed & zeena saadon & walaa kahtan 2015
 
EEG_circut.ppt
EEG_circut.pptEEG_circut.ppt
EEG_circut.ppt
 
EEG_circuit.ppt
EEG_circuit.pptEEG_circuit.ppt
EEG_circuit.ppt
 
K010225156
K010225156K010225156
K010225156
 
Acoustic fMRI noise reduction: a perceived loudness approach
Acoustic fMRI noise reduction: a perceived loudness approachAcoustic fMRI noise reduction: a perceived loudness approach
Acoustic fMRI noise reduction: a perceived loudness approach
 
Ecg
EcgEcg
Ecg
 
Sampling tutorial
Sampling tutorialSampling tutorial
Sampling tutorial
 
ultra sound.pptx
ultra sound.pptxultra sound.pptx
ultra sound.pptx
 
Revealing and evaluating the influence of filters position in cascaded filter...
Revealing and evaluating the influence of filters position in cascaded filter...Revealing and evaluating the influence of filters position in cascaded filter...
Revealing and evaluating the influence of filters position in cascaded filter...
 
PHONOCARDIOGRAM-BASED DIAGNOSIS USING MACHINE LEARNING: PARAMETRIC ESTIMATION...
PHONOCARDIOGRAM-BASED DIAGNOSIS USING MACHINE LEARNING: PARAMETRIC ESTIMATION...PHONOCARDIOGRAM-BASED DIAGNOSIS USING MACHINE LEARNING: PARAMETRIC ESTIMATION...
PHONOCARDIOGRAM-BASED DIAGNOSIS USING MACHINE LEARNING: PARAMETRIC ESTIMATION...
 
Phonocardiogram Based Diagnosis Using Machine Learning : Parametric Estimatio...
Phonocardiogram Based Diagnosis Using Machine Learning : Parametric Estimatio...Phonocardiogram Based Diagnosis Using Machine Learning : Parametric Estimatio...
Phonocardiogram Based Diagnosis Using Machine Learning : Parametric Estimatio...
 
Phonocardiogram Based Diagnosis Using Machine Learning : Parametric Estimatio...
Phonocardiogram Based Diagnosis Using Machine Learning : Parametric Estimatio...Phonocardiogram Based Diagnosis Using Machine Learning : Parametric Estimatio...
Phonocardiogram Based Diagnosis Using Machine Learning : Parametric Estimatio...
 
PHONOCARDIOGRAM-BASED DIAGNOSIS USING MACHINE LEARNING: PARAMETRIC ESTIMATION...
PHONOCARDIOGRAM-BASED DIAGNOSIS USING MACHINE LEARNING: PARAMETRIC ESTIMATION...PHONOCARDIOGRAM-BASED DIAGNOSIS USING MACHINE LEARNING: PARAMETRIC ESTIMATION...
PHONOCARDIOGRAM-BASED DIAGNOSIS USING MACHINE LEARNING: PARAMETRIC ESTIMATION...
 
BERA AND otoacoustic emission edited.pptx
BERA AND  otoacoustic emission edited.pptxBERA AND  otoacoustic emission edited.pptx
BERA AND otoacoustic emission edited.pptx
 
Basics of eeg signal
Basics of eeg signalBasics of eeg signal
Basics of eeg signal
 
Electronic noise filtering strategy in hemodynamic research
Electronic noise filtering strategy in hemodynamic researchElectronic noise filtering strategy in hemodynamic research
Electronic noise filtering strategy in hemodynamic research
 
EEG (ELECTROENCEPALOGRAM)
EEG (ELECTROENCEPALOGRAM)EEG (ELECTROENCEPALOGRAM)
EEG (ELECTROENCEPALOGRAM)
 
EEG Basics monish.pptx
EEG Basics monish.pptxEEG Basics monish.pptx
EEG Basics monish.pptx
 
Sleep 2008 Electronicsv.3
Sleep 2008 Electronicsv.3Sleep 2008 Electronicsv.3
Sleep 2008 Electronicsv.3
 

Recently uploaded

Integrated Test Rig For HTFE-25 - Neometrix
Integrated Test Rig For HTFE-25 - NeometrixIntegrated Test Rig For HTFE-25 - Neometrix
Integrated Test Rig For HTFE-25 - Neometrix
Neometrix_Engineering_Pvt_Ltd
 
1_Introduction + EAM Vocabulary + how to navigate in EAM.pdf
1_Introduction + EAM Vocabulary + how to navigate in EAM.pdf1_Introduction + EAM Vocabulary + how to navigate in EAM.pdf
1_Introduction + EAM Vocabulary + how to navigate in EAM.pdf
AldoGarca30
 
Hospital management system project report.pdf
Hospital management system project report.pdfHospital management system project report.pdf
Hospital management system project report.pdf
Kamal Acharya
 
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
ssuser89054b
 
Call Girls in South Ex (delhi) call me [🔝9953056974🔝] escort service 24X7
Call Girls in South Ex (delhi) call me [🔝9953056974🔝] escort service 24X7Call Girls in South Ex (delhi) call me [🔝9953056974🔝] escort service 24X7
Call Girls in South Ex (delhi) call me [🔝9953056974🔝] escort service 24X7
9953056974 Low Rate Call Girls In Saket, Delhi NCR
 

Recently uploaded (20)

Integrated Test Rig For HTFE-25 - Neometrix
Integrated Test Rig For HTFE-25 - NeometrixIntegrated Test Rig For HTFE-25 - Neometrix
Integrated Test Rig For HTFE-25 - Neometrix
 
AIRCANVAS[1].pdf mini project for btech students
AIRCANVAS[1].pdf mini project for btech studentsAIRCANVAS[1].pdf mini project for btech students
AIRCANVAS[1].pdf mini project for btech students
 
DC MACHINE-Motoring and generation, Armature circuit equation
DC MACHINE-Motoring and generation, Armature circuit equationDC MACHINE-Motoring and generation, Armature circuit equation
DC MACHINE-Motoring and generation, Armature circuit equation
 
1_Introduction + EAM Vocabulary + how to navigate in EAM.pdf
1_Introduction + EAM Vocabulary + how to navigate in EAM.pdf1_Introduction + EAM Vocabulary + how to navigate in EAM.pdf
1_Introduction + EAM Vocabulary + how to navigate in EAM.pdf
 
Moment Distribution Method For Btech Civil
Moment Distribution Method For Btech CivilMoment Distribution Method For Btech Civil
Moment Distribution Method For Btech Civil
 
Wadi Rum luxhotel lodge Analysis case study.pptx
Wadi Rum luxhotel lodge Analysis case study.pptxWadi Rum luxhotel lodge Analysis case study.pptx
Wadi Rum luxhotel lodge Analysis case study.pptx
 
Hospital management system project report.pdf
Hospital management system project report.pdfHospital management system project report.pdf
Hospital management system project report.pdf
 
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
 
GEAR TRAIN- BASIC CONCEPTS AND WORKING PRINCIPLE
GEAR TRAIN- BASIC CONCEPTS AND WORKING PRINCIPLEGEAR TRAIN- BASIC CONCEPTS AND WORKING PRINCIPLE
GEAR TRAIN- BASIC CONCEPTS AND WORKING PRINCIPLE
 
Thermal Engineering-R & A / C - unit - V
Thermal Engineering-R & A / C - unit - VThermal Engineering-R & A / C - unit - V
Thermal Engineering-R & A / C - unit - V
 
Computer Lecture 01.pptxIntroduction to Computers
Computer Lecture 01.pptxIntroduction to ComputersComputer Lecture 01.pptxIntroduction to Computers
Computer Lecture 01.pptxIntroduction to Computers
 
A CASE STUDY ON CERAMIC INDUSTRY OF BANGLADESH.pptx
A CASE STUDY ON CERAMIC INDUSTRY OF BANGLADESH.pptxA CASE STUDY ON CERAMIC INDUSTRY OF BANGLADESH.pptx
A CASE STUDY ON CERAMIC INDUSTRY OF BANGLADESH.pptx
 
COST-EFFETIVE and Energy Efficient BUILDINGS ptx
COST-EFFETIVE  and Energy Efficient BUILDINGS ptxCOST-EFFETIVE  and Energy Efficient BUILDINGS ptx
COST-EFFETIVE and Energy Efficient BUILDINGS ptx
 
Generative AI or GenAI technology based PPT
Generative AI or GenAI technology based PPTGenerative AI or GenAI technology based PPT
Generative AI or GenAI technology based PPT
 
kiln thermal load.pptx kiln tgermal load
kiln thermal load.pptx kiln tgermal loadkiln thermal load.pptx kiln tgermal load
kiln thermal load.pptx kiln tgermal load
 
Call Girls in South Ex (delhi) call me [🔝9953056974🔝] escort service 24X7
Call Girls in South Ex (delhi) call me [🔝9953056974🔝] escort service 24X7Call Girls in South Ex (delhi) call me [🔝9953056974🔝] escort service 24X7
Call Girls in South Ex (delhi) call me [🔝9953056974🔝] escort service 24X7
 
Introduction to Serverless with AWS Lambda
Introduction to Serverless with AWS LambdaIntroduction to Serverless with AWS Lambda
Introduction to Serverless with AWS Lambda
 
Engineering Drawing focus on projection of planes
Engineering Drawing focus on projection of planesEngineering Drawing focus on projection of planes
Engineering Drawing focus on projection of planes
 
Hostel management system project report..pdf
Hostel management system project report..pdfHostel management system project report..pdf
Hostel management system project report..pdf
 
A Study of Urban Area Plan for Pabna Municipality
A Study of Urban Area Plan for Pabna MunicipalityA Study of Urban Area Plan for Pabna Municipality
A Study of Urban Area Plan for Pabna Municipality
 

Medical applications of dsp

  • 1. MEDICAL APPLICATIONS OF DSP Made by- Digisha Singhal 13bec026 Kinjal Aggrawal 13bec054 Guided by- Dr. Mehul Naik
  • 2. 1. Introduction 2. Applications 3. Hearing aid 4. Brain signals – electroencephalogram 5. The acquisition of a blood pressure signal 6. References
  • 3.  Most natural phenomena occur continuously in time, such as the variations of temperature of the human body, forces exerted by muscles, or electrical potentials generated on the surface of the scalp.  By sampling these analog signal, digital signals are formed.  Major applications of DSP in the field of medicine are widely applied in patient monitoring, diagnosis, as well as physiological investigation and in some therapeutic settings (e.g. Muscle and sensory stimulation, hearing aids).
  • 4.  Hearing aid  Brain signals – electroencephalogram  The acquisition of a blood pressure signal
  • 5.  The sound is picked up by the microphone, is converted into an electric signal, and then digitized.  The digital signal is then filtered to selectively amplify those frequency bands in which the patient shows the most severe hearing loss.  Amplitude compression, in which the system gain is reduced when the amplitude exceeds some pre-defined threshold values, in order to avoid excessive loudness to the ear is also used.  Finally the processed digital signal is converted back to analog form in the digital-to-analog (D/A) converter, and delivered to the ear via the earphone.
  • 6. In a further stage of signal processing in hearing aids, the amplitude-range may be compressed. Hence, the gain of the system is progressively reduced when the sound-volume exceeds a specified level, as is the case near the end of this recording. A small delay in adapting the gain to the signal-levels may also be added, as the average of the most recent amplitudes drives the gain control.
  • 7.  The two basic, non-invasive, brain signals are the EEG.  Both find use in routine neuro-physiological evaluation, for e.g. diagnosis and following the development of brain diseases, and in monitoring anaesthetised patients during medical operations.  The EEG is the electrical activity of the brain and may contain diagnostic information for a variety of neurological conditions, such as sleep disorders, and coma.  They are often described by the frequency band in which they lie ( e.g alpha rhythm, beta activity, delta waves), and by their amplitude, and the pattern of distribution on the scalp.
  • 8. 4 second excerpt from as EEG
  • 9.  The characteristics of the EEG vary considerably with the state of the patient, e.g whether the patient's eyes are open or closed, whether the patient is drowsy, soundly asleep, asleep and dreaming.  The EEG lends itself to time and frequency analysis.
  • 10. Segment of the original EEG signal (solid line), and the same signal reconstructed from only its DFT components in the α frequency band (dotted line). The oscillation in the frequency band of 8-13 Hz is enhanced. The slow change during the artefact in the EEG signal around 29.5 s is eliminated, as are some of the faster variations (higher frequency beta activity, and noise ) seen in the raw data.
  • 11.  Spectral estimation: Spectral estimation helps in finding the pulse rhythms present in the EEG signal. The short segment of EEG data is analyzed for spectral parameters such as location and amount of spectral energy. Wave-shaping filters are extensively used in this technique. Wave shaping filters produce desired output signal for given input signal.  ARMA (autoregressive moving average) method: This model is suggested for modelling signals with sharp peaks and valleys in their frequency content and also signals with severe background noise.
  • 12. Frequency response |f(H)| of a second-order Butterworth band-pass filter, with cut-off frequencies at 8 and 13 Hz. This filter will preserve activity in the alpha frequency band, while attenuating other frequency bands.
  • 13. Using and IIR filter with coefficients a=[1 -7.43 24.44 -46.33 55.38 -42.75 20.82 -5.84 0.72] and b =10-4 [0.12 0 -0.48 0 0.720 -0.48 0 0.12], very rapid change and slow variations are eliminated, and only the signal components in the alpha frequency band are maintained. An IIR filter is used to enhance the alpha activity in an EEG signal that contains mains interference (50 Hz), and noise.
  • 14.  A blood pressure (BP) signal contains clinically relevant components up to about 20 Hz.  The signal is contaminated by noise at the mains frequency (50 Hz) and other noise (mainly below 50 Hz) may also be present  Thus the sampling rate has to be above 100Hz, as the highest frequency present is 50 Hz.  If the noise (mains interference) is removed prior to sampling, by a low-pass (anti-alias) filter with a cut-off frequency at say 20 Hz, the sampling rate could be reduced to a value above 40 Hz, without significant aliasing occurring.
  • 15. The power spectrum of this signal, sampled at 67 Hz. Without the anti-alias filter (dotted lines), the 50 Hz noise is aliased, and appears as a very large peak at 17 Hz (67- 50 Hz). With the anti-alias filter (solid line), this peak is very much reduced (though not eliminated, due to the imperfection of the filter), and can be considered insignificant.
  • 16.  H. Nyquist (1928) Certain Topics in Telegraph Transmission Theory. Trans. AIEE, vol. 47, pp. 617-644.  A. Antoniou. (1993) Digital Filters: Analysis, Design and Applications. New York, NY: McGraw-Hill, 2nd Edition.  L. B. Jackson. (1996) Digital Filters and Signal Processing. Boston, MA: Kluwer, 3rd Edition.  A. V. Oppenheim, and R. W. Schafer (1989). Discrete-Time Signal Processing. Englewood Cliffs, NJ: Prentice Hall.  S. K. Mitra. (2001) Digital Signal Processing: A Computer-Based Approach. New York, NY: McGraw-Hill, 2nd Edition.