SlideShare une entreprise Scribd logo
1  sur  6
Télécharger pour lire hors ligne
NH FC-01
                                                           RESIDENTIAL CUT-AWAY WALL SECTION


Typical Wall System:
Standard 2x6 Wood Frame Wall with Fiber Cement Board Siding

                                                                      Primed and Painted Interior Finish
                                                                      Gypsum Board
                                                                      Gypsum Board Tape and Mud
                                                                      Fastener at Gypsum Board Joint
                                                                      Vapor Barrier
                                                                      2X6 Wood Stud, 16” O.C.
                                                                      Blown-In Insulation
                                                                      1/2” Exterior Sheathing
                                                                      Sheathing Fasteners
                                                                      House Wrap
                                                                      Fiber Cement Board Lap Siding
                                                                      Siding Fastener
                                                                      Base Furring with Fastener




                                                        Insulative R-Value                                   18.1
                                                        Efficiency of Construction (# of Trades)             5
                                                        Approximate Wall Thickness                           7”
                                                        Embodied Carbon Dioxide Output*                      +10.8
                                                        in kilograms per square foot
                                                        Recyclable or Biodegradable Content                  71%
                                                        Materials with Volatile Chemical Content             9%
                                                        Approximate Cost Per Square Foot                     $16
                                                       The above figures are estimated with common building
                                                       materials and practices, and are not specific to any single
                                                       manufacturer. It reflects the performance of mid-wall
                                                       conditions only and does not take into account floor, roof,
                                                       corner, opening or mechanical conditions.

                                                       *Source:  Athena Institute and University of Minnesota, US Life
                                                       Cycle Inventory Database, EcoCalculator for Assemblies.


                                                                         website: http://www.americanlimetec.com
                                 LAST REVISED 2010-11-16                         email: info@americanlimetec.com
                        COPYRIGHT 2010 AMERICAN LIME TECHNOLOGY.                          telephone: 773.286.0566
NH BV-01
                                                            RESIDENTIAL CUT-AWAY WALL SECTION


Typical Wall System:
Standard 2x6 Wood Frame Wall with Brick Veneer
                                                                  Primed and Painted Interior Finish
                                                                  Gypsum Board
                                                                  Gypsum Board Tape and Mud
                                                                  Fastener at Gypsum Board Joint
                                                                  Vapor Barrier
                                                                  2X6 Wood Stud, 16” O.C.
                                                                  Batt Insulation
                                                                  1/2” Exterior Sheathing
                                                                  Sheathing Fastener
                                                                  House Wrap
                                                                  Brick Tie
                                                                  Air Cavity
                                                                  Brick Veneer
                                                                  Flashing with Continuous Fastener
                                                                  Strip
                                                                  Mortar Net at Base of Air Cavity
                                                                  Weep Vent
                                                                  Stainless Steel Counterflashing




                                                         Insulative R-Value                                   17.5
                                                         Efficiency of Construction (# of Trades)             5
                                                         Approximate Wall Thickness                           11.5”
                                                         Embodied Carbon Dioxide Output*                      +9
                                                         in kilograms per square foot
                                                         Recyclable or Biodegradable Content                  11%
                                                         Materials with Volatile Chemical Content             61%
                                                         Approximate Cost Per Square Foot                     $25
                                                        The above figures are estimated with common building
                                                        materials and practices, and are not specific to any single
                                                        manufacturer. It reflects the performance of mid-wall
                                                        conditions only and does not take into account floor, roof,
                                                        corner, opening or mechanical conditions.

                                                        *Source:  Athena Institute and University of Minnesota, US Life
                                                        Cycle Inventory Database, EcoCalculator for Assemblies.


                                                                               website: http://www.americanlimetec.com
                                LAST REVISED 2010-11-16                                email: info@americanlimetec.com
                       COPYRIGHT 2010 AMERICAN LIME TECHNOLOGY.                                 telephone: 773.286.0566
NH S-01
                                                           RESIDENTIAL CUT-AWAY WALL SECTION


Typical Wall System:
Standard CMU Wall with Stucco Exterior

                                                                    Primed and Painted Interior Finish
                                                                    Gypsum Board
                                                                    Gypsum Board Tape and Mud
                                                                    Fasteners at Gypsum Board Joint
                                                                    2X2 Wood Furring, 16” O.C.
                                                                    1 1/2” Rigid Insulation
                                                                    8” CMU (Concrete Masonry Unit)
                                                                    CMU Wire Reinforcement
                                                                    House Wrap
                                                                    Stucco Reinforcing Mesh
                                                                    Stucco Base Coat
                                                                    Stucco Finish Coat
                                                                    Paint Coat
                                                                    Stainless Steel Weep Screed




                                                        Insulative R-Value                                   6.5
                                                        Efficiency of Construction (# of Trades)             6
                                                        Approximate Wall Thickness                           10.75”
                                                        Embodied Carbon Dioxide Output*                      +16.3
                                                        in kilograms per square foot
                                                        Recyclable or Biodegradable Content                  5%
                                                        Materials with Volatile Chemical Content             15%
                                                        Approximate Material Cost Per Sq. Foot               $25
                                                       The above figures are estimated with common building
                                                       materials and practices, and are not specific to any single
                                                       manufacturer. It reflects the performance of mid-wall
                                                       conditions only and does not take into account floor, roof,
                                                       corner, opening or mechanical conditions.

                                                       *Source:  Athena Institute and University of Minnesota, US Life
                                                       Cycle Inventory Database, EcoCalculator for Assemblies.


                                                                         website: http://www.americanlimetec.com
                                 LAST REVISED 2010-11-16                         email: info@americanlimetec.com
                        COPYRIGHT 2010 AMERICAN LIME TECHNOLOGY.                          telephone: 773.286.0566
NH EIFS-01
                                                           COMMERCIAL CUT-AWAY WALL SECTION


Typical Wall System:
Standard Light-Gauge Metal Frame Wall with
EIFS (Exterior Insulation Finish System)
                                                                     Primed and Painted Interior Finish
                                                                     Gypsum Board
                                                                     Gypsum Board Tape and Mud
                                                                     Vapor Barrier
                                                                     6” Light Gauge Metal Framing, 24” O.C.
                                                                     Fastener at Sheathing
                                                                     Fasteners at Gypsum Board Joint
                                                                     Batt Insulation
                                                                     1/2” Sheathing
                                                                     Air Barrier Wrap
                                                                     Rigid Insulation Adhesive
                                                                     2” Rigid Insulation
                                                                     EIFS Reinforcing Mesh
                                                                     EIFS Base Coat
                                                                     EIFS Finish Coat
                                                                     Paint Coat
                                                                     Flashing with Continuous Fastener Strip




                                                         Insulative R-Value                                   18.7
                                                         Efficiency of Construction (# of Trades)             5
                                                         Approximate Wall Thickness                           9.75”
                                                         Embodied Carbon Dioxide Output*                      +13.2
                                                         in kilograms per square foot
                                                         Recyclable or Biodegradable Content                  6%
                                                         Materials with Volatile Chemical Content             88%
                                                         Approximate Material Cost Per Sq. Foot               $22
                                                        The above figures are estimated with common building
                                                        materials and practices, and are not specific to any single
                                                        manufacturer. It reflects the performance of mid-wall
                                                        conditions only and does not take into account floor, roof,
                                                        corner, opening or mechanical conditions.

                                                        *Source:  Athena Institute and University of Minnesota, US Life
                                                        Cycle Inventory Database, EcoCalculator for Assemblies.


                                                                          website: http://www.americanlimetec.com
                                LAST REVISED 2010-11-16                           email: info@americanlimetec.com
                       COPYRIGHT 2010 AMERICAN LIME TECHNOLOGY.                            telephone: 773.286.0566
NH PC-01
                                                          COMMERCIAL CUT-AWAY WALL SECTION


Typical Wall System:
Standard Precast Concrete Wall

                                                                   Primed and Painted Interior Finish
                                                                   Gypsum Board Tape and Mud
                                                                   5/8” Gypsum Board
                                                                   Vapor Barrier
                                                                   Fasteners at Gypsum Board Joint
                                                                   2” Light Gauge Metal Furring Channels,
                                                                   24” O.C.
                                                                   2” Rigid Insulation
                                                                   Precast Concrete Wall Panel
                                                                   Precast Steel Rebar Reinforcement Grid
                                                                   Prime and Paint Coat
                                                                   Steel Rebar Reinforcement Grid (welded
                                                                   to Precast Wall Panel Rebar before
                                                                   Concrete Slab is Poured)
                                                                   Fluid-Applied Foundation Waterproofing
                                                                   Membrane (below grade)




                                                        Insulative R-Value                                   7.5
                                                        Efficiency of Construction (# of Trades)             5
                                                        Approximate Wall Thickness                           9”
                                                        Embodied Carbon Dioxide Output*                      +11.4
                                                        in kilograms per square foot
                                                        Recyclable or Biodegradable Content                  66%
                                                        Materials with Volatile Chemical Content             25%
                                                        Approximate Cost Per Square Foot                     $29
                                                       The above figures are estimated with common building
                                                       materials and practices, and are not specific to any single
                                                       manufacturer. It reflects the performance of mid-wall
                                                       conditions only and does not take into account floor, roof,
                                                       corner, opening or mechanical conditions.

                                                       *Source:  Athena Institute and University of Minnesota, US Life
                                                       Cycle Inventory Database, EcoCalculator for Assemblies.


                                                                          website: http://www.americanlimetec.com
                                 LAST REVISED 2010-11-16                          email: info@americanlimetec.com
                        COPYRIGHT 2010 AMERICAN LIME TECHNOLOGY.                           telephone: 773.286.0566
NH BV-02
                                                           COMMERCIAL CUT-AWAY WALL SECTION


Typical Wall System:
Standard CMU Wall with Brick Veneer

                                                                                Primed and Painted Interior Finish
                                                                                Gypsum Board
                                                                                Gypsum Board Tape and Mud
                                                                                Vapor Barrier
                                                                                3 5/8” Light-Gauge Metal Framing,
                                                                                24” O.C.
                                                                                Batt Insulation
                                                                                Fasteners at Gypsum Board Joint
                                                                                CMU Wire Reinforcement
                                                                                8” CMU (Concrete Masonry Unit)
                                                                                Brick Tie
                                                                                Air Barrier Wrap
                                                                                2” Rigid Insulation
                                                                                Air Cavity
                                                                                Brick Veneer
                                                                                Mortar Net at Base of Air Cavity
                                                                                Flashing with Continuous Fastener
                                                                                Strip
                                                                                Weep Vent
                                                                                Stainless Steel Counterflashing




                                                         Insulative R-Value                                   17.6
                                                         Efficiency of Construction (# of Trades)             5
                                                         Approximate Wall Thickness                           18.5”
                                                         Embodied Carbon Dioxide Output*                      +21.8
                                                         in kilograms per square foot
                                                         Recyclable or Biodegradable Content                  4%
                                                         Materials with Volatile Chemical Content             35%
                                                         Approximate Cost Per Square Foot                     $42
                                                        The above figures are estimated with common building
                                                        materials and practices, and are not specific to any single
                                                        manufacturer. It reflects the performance of mid-wall
                                                        conditions only and does not take into account floor, roof,
                                                        corner, opening or mechanical conditions.

                                                        *Source:  Athena Institute and University of Minnesota, US Life
                                                        Cycle Inventory Database, EcoCalculator for Assemblies.


                                                                          website: http://www.americanlimetec.com
                                LAST REVISED 2010-11-16                           email: info@americanlimetec.com
                       COPYRIGHT 2010 AMERICAN LIME TECHNOLOGY.                            telephone: 773.286.0566

Contenu connexe

Tendances

PermaTherm Expanded Polystyrene DataSheet
PermaTherm Expanded Polystyrene DataSheetPermaTherm Expanded Polystyrene DataSheet
PermaTherm Expanded Polystyrene DataSheetKen Madren
 
Andersen 100 Series Product Presentation
Andersen 100 Series Product PresentationAndersen 100 Series Product Presentation
Andersen 100 Series Product PresentationAndersen Windows
 
A5 1900 - Janstar Homes www.janstar.com
A5 1900 - Janstar Homes  www.janstar.comA5 1900 - Janstar Homes  www.janstar.com
A5 1900 - Janstar Homes www.janstar.comLindal Cedar Homes
 
Rockfon Dekor Broc Pics
Rockfon Dekor Broc PicsRockfon Dekor Broc Pics
Rockfon Dekor Broc Picsrockfonceiling
 
Rooftime attic hatch insulation
Rooftime attic hatch insulationRooftime attic hatch insulation
Rooftime attic hatch insulationA New Rooftime
 
Sort overview of what we do
Sort overview of what we doSort overview of what we do
Sort overview of what we doJoe Tillman
 
Chris Harrold - Future is here in Automotive coatings
Chris Harrold - Future is here in Automotive coatingsChris Harrold - Future is here in Automotive coatings
Chris Harrold - Future is here in Automotive coatingsponencias.eurosurfas2011
 
2011 Coachmen Freelander
2011 Coachmen Freelander2011 Coachmen Freelander
2011 Coachmen Freelanderdarjmich
 
Andersen A-Series Product Presentation
Andersen A-Series Product PresentationAndersen A-Series Product Presentation
Andersen A-Series Product PresentationAndersen Windows
 
Coachmen Freelander 2013 Brochure
Coachmen Freelander 2013 BrochureCoachmen Freelander 2013 Brochure
Coachmen Freelander 2013 Brochuredarjmich
 
Rockfon Steel Finish Pics
Rockfon  Steel  Finish  PicsRockfon  Steel  Finish  Pics
Rockfon Steel Finish Picsrockfonceiling
 
A2 1300 - Janstar Homes www.janstar.com
A2 1300 - Janstar Homes  www.janstar.comA2 1300 - Janstar Homes  www.janstar.com
A2 1300 - Janstar Homes www.janstar.comLindal Cedar Homes
 

Tendances (18)

Prospekt desig nline_connect_laguna_eng
Prospekt desig nline_connect_laguna_engProspekt desig nline_connect_laguna_eng
Prospekt desig nline_connect_laguna_eng
 
PermaTherm Expanded Polystyrene DataSheet
PermaTherm Expanded Polystyrene DataSheetPermaTherm Expanded Polystyrene DataSheet
PermaTherm Expanded Polystyrene DataSheet
 
Rockfon Sonar Pics
Rockfon Sonar PicsRockfon Sonar Pics
Rockfon Sonar Pics
 
Lockwood classic
Lockwood classicLockwood classic
Lockwood classic
 
Andersen 100 Series Product Presentation
Andersen 100 Series Product PresentationAndersen 100 Series Product Presentation
Andersen 100 Series Product Presentation
 
A5 1900 - Janstar Homes www.janstar.com
A5 1900 - Janstar Homes  www.janstar.comA5 1900 - Janstar Homes  www.janstar.com
A5 1900 - Janstar Homes www.janstar.com
 
Rockfon Dekor Broc Pics
Rockfon Dekor Broc PicsRockfon Dekor Broc Pics
Rockfon Dekor Broc Pics
 
Rooftime attic hatch insulation
Rooftime attic hatch insulationRooftime attic hatch insulation
Rooftime attic hatch insulation
 
Sort overview of what we do
Sort overview of what we doSort overview of what we do
Sort overview of what we do
 
Chris Harrold - Future is here in Automotive coatings
Chris Harrold - Future is here in Automotive coatingsChris Harrold - Future is here in Automotive coatings
Chris Harrold - Future is here in Automotive coatings
 
2011 Coachmen Freelander
2011 Coachmen Freelander2011 Coachmen Freelander
2011 Coachmen Freelander
 
Andersen A-Series Product Presentation
Andersen A-Series Product PresentationAndersen A-Series Product Presentation
Andersen A-Series Product Presentation
 
2010 Catalogue
2010 Catalogue2010 Catalogue
2010 Catalogue
 
Coachmen Freelander 2013 Brochure
Coachmen Freelander 2013 BrochureCoachmen Freelander 2013 Brochure
Coachmen Freelander 2013 Brochure
 
B32006009
B32006009B32006009
B32006009
 
A1 1200 - Janstar Homes
A1 1200 - Janstar HomesA1 1200 - Janstar Homes
A1 1200 - Janstar Homes
 
Rockfon Steel Finish Pics
Rockfon  Steel  Finish  PicsRockfon  Steel  Finish  Pics
Rockfon Steel Finish Pics
 
A2 1300 - Janstar Homes www.janstar.com
A2 1300 - Janstar Homes  www.janstar.comA2 1300 - Janstar Homes  www.janstar.com
A2 1300 - Janstar Homes www.janstar.com
 

En vedette

308 East Green Street Revit Project Book
308 East Green Street Revit Project Book308 East Green Street Revit Project Book
308 East Green Street Revit Project BookThomas McCormick
 
Bodyguard Slide
Bodyguard SlideBodyguard Slide
Bodyguard SlideRandy Thai
 
206.03 wood frame_wall_construction
206.03 wood frame_wall_construction206.03 wood frame_wall_construction
206.03 wood frame_wall_constructionShruthi Gowda
 
SerVilla - LGS Light Gauge Steel Frame Construction - Steel Villa
SerVilla - LGS Light Gauge Steel Frame Construction - Steel VillaSerVilla - LGS Light Gauge Steel Frame Construction - Steel Villa
SerVilla - LGS Light Gauge Steel Frame Construction - Steel VillaSerVilla Anahtar Teslim Villa
 

En vedette (6)

308 East Green Street Revit Project Book
308 East Green Street Revit Project Book308 East Green Street Revit Project Book
308 East Green Street Revit Project Book
 
Bodyguard Slide
Bodyguard SlideBodyguard Slide
Bodyguard Slide
 
206.03 wood frame_wall_construction
206.03 wood frame_wall_construction206.03 wood frame_wall_construction
206.03 wood frame_wall_construction
 
SerVilla - LGS Light Gauge Steel Frame Construction - Steel Villa
SerVilla - LGS Light Gauge Steel Frame Construction - Steel VillaSerVilla - LGS Light Gauge Steel Frame Construction - Steel Villa
SerVilla - LGS Light Gauge Steel Frame Construction - Steel Villa
 
Roofs
RoofsRoofs
Roofs
 
Doors & windows
Doors & windowsDoors & windows
Doors & windows
 

Similaire à Nh data shts 11 17-10

A4 1700 - Janstar Homes www.janstar.com
A4 1700 - Janstar Homes www.janstar.comA4 1700 - Janstar Homes www.janstar.com
A4 1700 - Janstar Homes www.janstar.comLindal Cedar Homes
 
Cal Portland Standard Icf, Pervious, Decorative
Cal Portland Standard Icf, Pervious, DecorativeCal Portland Standard Icf, Pervious, Decorative
Cal Portland Standard Icf, Pervious, Decorativereubendr
 
Wood Veneer Spc performance handbook 2021
Wood Veneer Spc performance handbook 2021Wood Veneer Spc performance handbook 2021
Wood Veneer Spc performance handbook 2021Crystal Qi Cheng
 
Stryrozone Roof Garden Systems
Stryrozone Roof Garden SystemsStryrozone Roof Garden Systems
Stryrozone Roof Garden SystemsFlanna489y
 

Similaire à Nh data shts 11 17-10 (6)

A3 1200 - Janstar Homes
A3 1200 - Janstar HomesA3 1200 - Janstar Homes
A3 1200 - Janstar Homes
 
A4 1700 - Janstar Homes www.janstar.com
A4 1700 - Janstar Homes www.janstar.comA4 1700 - Janstar Homes www.janstar.com
A4 1700 - Janstar Homes www.janstar.com
 
Cal Portland Standard Icf, Pervious, Decorative
Cal Portland Standard Icf, Pervious, DecorativeCal Portland Standard Icf, Pervious, Decorative
Cal Portland Standard Icf, Pervious, Decorative
 
Wood Veneer Spc performance handbook 2021
Wood Veneer Spc performance handbook 2021Wood Veneer Spc performance handbook 2021
Wood Veneer Spc performance handbook 2021
 
Stryrozone Roof Garden Systems
Stryrozone Roof Garden SystemsStryrozone Roof Garden Systems
Stryrozone Roof Garden Systems
 
GigaHouses
GigaHousesGigaHouses
GigaHouses
 

Plus de limetech

Litd 2600 winter 2010 newsletter3
Litd 2600 winter 2010 newsletter3Litd 2600 winter 2010 newsletter3
Litd 2600 winter 2010 newsletter3limetech
 
Hemcrete testing evaluation usa
Hemcrete testing evaluation usaHemcrete testing evaluation usa
Hemcrete testing evaluation usalimetech
 
Hemcoat limeplastermethodsheet
Hemcoat limeplastermethodsheetHemcoat limeplastermethodsheet
Hemcoat limeplastermethodsheetlimetech
 
Thermal performance of hemcrete with photos
Thermal performance of hemcrete with photosThermal performance of hemcrete with photos
Thermal performance of hemcrete with photoslimetech
 
North carolina 2 jan 2009
North carolina 2 jan 2009North carolina 2 jan 2009
North carolina 2 jan 2009limetech
 
Existing and future projects
Existing and future projectsExisting and future projects
Existing and future projectslimetech
 
Ecobuild stand 2007mh1
Ecobuild stand 2007mh1Ecobuild stand 2007mh1
Ecobuild stand 2007mh1limetech
 
North carolina 2 jan 2009
North carolina 2 jan 2009North carolina 2 jan 2009
North carolina 2 jan 2009limetech
 
Brico pres
Brico presBrico pres
Brico preslimetech
 
American lime technology sep. 15, 2010
American lime technology sep. 15, 2010American lime technology sep. 15, 2010
American lime technology sep. 15, 2010limetech
 
American lime technology nov. 25, 2008
American lime technology nov. 25, 2008American lime technology nov. 25, 2008
American lime technology nov. 25, 2008limetech
 
American lime technology delegate presentation
American lime technology delegate presentationAmerican lime technology delegate presentation
American lime technology delegate presentationlimetech
 
American lime tech business plan outline 082409
American lime tech business plan outline 082409American lime tech business plan outline 082409
American lime tech business plan outline 082409limetech
 
Ultimate green building lime & industrial hemp
Ultimate green building   lime & industrial hempUltimate green building   lime & industrial hemp
Ultimate green building lime & industrial hemplimetech
 

Plus de limetech (14)

Litd 2600 winter 2010 newsletter3
Litd 2600 winter 2010 newsletter3Litd 2600 winter 2010 newsletter3
Litd 2600 winter 2010 newsletter3
 
Hemcrete testing evaluation usa
Hemcrete testing evaluation usaHemcrete testing evaluation usa
Hemcrete testing evaluation usa
 
Hemcoat limeplastermethodsheet
Hemcoat limeplastermethodsheetHemcoat limeplastermethodsheet
Hemcoat limeplastermethodsheet
 
Thermal performance of hemcrete with photos
Thermal performance of hemcrete with photosThermal performance of hemcrete with photos
Thermal performance of hemcrete with photos
 
North carolina 2 jan 2009
North carolina 2 jan 2009North carolina 2 jan 2009
North carolina 2 jan 2009
 
Existing and future projects
Existing and future projectsExisting and future projects
Existing and future projects
 
Ecobuild stand 2007mh1
Ecobuild stand 2007mh1Ecobuild stand 2007mh1
Ecobuild stand 2007mh1
 
North carolina 2 jan 2009
North carolina 2 jan 2009North carolina 2 jan 2009
North carolina 2 jan 2009
 
Brico pres
Brico presBrico pres
Brico pres
 
American lime technology sep. 15, 2010
American lime technology sep. 15, 2010American lime technology sep. 15, 2010
American lime technology sep. 15, 2010
 
American lime technology nov. 25, 2008
American lime technology nov. 25, 2008American lime technology nov. 25, 2008
American lime technology nov. 25, 2008
 
American lime technology delegate presentation
American lime technology delegate presentationAmerican lime technology delegate presentation
American lime technology delegate presentation
 
American lime tech business plan outline 082409
American lime tech business plan outline 082409American lime tech business plan outline 082409
American lime tech business plan outline 082409
 
Ultimate green building lime & industrial hemp
Ultimate green building   lime & industrial hempUltimate green building   lime & industrial hemp
Ultimate green building lime & industrial hemp
 

Nh data shts 11 17-10

  • 1. NH FC-01 RESIDENTIAL CUT-AWAY WALL SECTION Typical Wall System: Standard 2x6 Wood Frame Wall with Fiber Cement Board Siding Primed and Painted Interior Finish Gypsum Board Gypsum Board Tape and Mud Fastener at Gypsum Board Joint Vapor Barrier 2X6 Wood Stud, 16” O.C. Blown-In Insulation 1/2” Exterior Sheathing Sheathing Fasteners House Wrap Fiber Cement Board Lap Siding Siding Fastener Base Furring with Fastener Insulative R-Value 18.1 Efficiency of Construction (# of Trades) 5 Approximate Wall Thickness 7” Embodied Carbon Dioxide Output* +10.8 in kilograms per square foot Recyclable or Biodegradable Content 71% Materials with Volatile Chemical Content 9% Approximate Cost Per Square Foot $16 The above figures are estimated with common building materials and practices, and are not specific to any single manufacturer. It reflects the performance of mid-wall conditions only and does not take into account floor, roof, corner, opening or mechanical conditions. *Source: Athena Institute and University of Minnesota, US Life Cycle Inventory Database, EcoCalculator for Assemblies. website: http://www.americanlimetec.com LAST REVISED 2010-11-16 email: info@americanlimetec.com COPYRIGHT 2010 AMERICAN LIME TECHNOLOGY. telephone: 773.286.0566
  • 2. NH BV-01 RESIDENTIAL CUT-AWAY WALL SECTION Typical Wall System: Standard 2x6 Wood Frame Wall with Brick Veneer Primed and Painted Interior Finish Gypsum Board Gypsum Board Tape and Mud Fastener at Gypsum Board Joint Vapor Barrier 2X6 Wood Stud, 16” O.C. Batt Insulation 1/2” Exterior Sheathing Sheathing Fastener House Wrap Brick Tie Air Cavity Brick Veneer Flashing with Continuous Fastener Strip Mortar Net at Base of Air Cavity Weep Vent Stainless Steel Counterflashing Insulative R-Value 17.5 Efficiency of Construction (# of Trades) 5 Approximate Wall Thickness 11.5” Embodied Carbon Dioxide Output* +9 in kilograms per square foot Recyclable or Biodegradable Content 11% Materials with Volatile Chemical Content 61% Approximate Cost Per Square Foot $25 The above figures are estimated with common building materials and practices, and are not specific to any single manufacturer. It reflects the performance of mid-wall conditions only and does not take into account floor, roof, corner, opening or mechanical conditions. *Source: Athena Institute and University of Minnesota, US Life Cycle Inventory Database, EcoCalculator for Assemblies. website: http://www.americanlimetec.com LAST REVISED 2010-11-16 email: info@americanlimetec.com COPYRIGHT 2010 AMERICAN LIME TECHNOLOGY. telephone: 773.286.0566
  • 3. NH S-01 RESIDENTIAL CUT-AWAY WALL SECTION Typical Wall System: Standard CMU Wall with Stucco Exterior Primed and Painted Interior Finish Gypsum Board Gypsum Board Tape and Mud Fasteners at Gypsum Board Joint 2X2 Wood Furring, 16” O.C. 1 1/2” Rigid Insulation 8” CMU (Concrete Masonry Unit) CMU Wire Reinforcement House Wrap Stucco Reinforcing Mesh Stucco Base Coat Stucco Finish Coat Paint Coat Stainless Steel Weep Screed Insulative R-Value 6.5 Efficiency of Construction (# of Trades) 6 Approximate Wall Thickness 10.75” Embodied Carbon Dioxide Output* +16.3 in kilograms per square foot Recyclable or Biodegradable Content 5% Materials with Volatile Chemical Content 15% Approximate Material Cost Per Sq. Foot $25 The above figures are estimated with common building materials and practices, and are not specific to any single manufacturer. It reflects the performance of mid-wall conditions only and does not take into account floor, roof, corner, opening or mechanical conditions. *Source: Athena Institute and University of Minnesota, US Life Cycle Inventory Database, EcoCalculator for Assemblies. website: http://www.americanlimetec.com LAST REVISED 2010-11-16 email: info@americanlimetec.com COPYRIGHT 2010 AMERICAN LIME TECHNOLOGY. telephone: 773.286.0566
  • 4. NH EIFS-01 COMMERCIAL CUT-AWAY WALL SECTION Typical Wall System: Standard Light-Gauge Metal Frame Wall with EIFS (Exterior Insulation Finish System) Primed and Painted Interior Finish Gypsum Board Gypsum Board Tape and Mud Vapor Barrier 6” Light Gauge Metal Framing, 24” O.C. Fastener at Sheathing Fasteners at Gypsum Board Joint Batt Insulation 1/2” Sheathing Air Barrier Wrap Rigid Insulation Adhesive 2” Rigid Insulation EIFS Reinforcing Mesh EIFS Base Coat EIFS Finish Coat Paint Coat Flashing with Continuous Fastener Strip Insulative R-Value 18.7 Efficiency of Construction (# of Trades) 5 Approximate Wall Thickness 9.75” Embodied Carbon Dioxide Output* +13.2 in kilograms per square foot Recyclable or Biodegradable Content 6% Materials with Volatile Chemical Content 88% Approximate Material Cost Per Sq. Foot $22 The above figures are estimated with common building materials and practices, and are not specific to any single manufacturer. It reflects the performance of mid-wall conditions only and does not take into account floor, roof, corner, opening or mechanical conditions. *Source: Athena Institute and University of Minnesota, US Life Cycle Inventory Database, EcoCalculator for Assemblies. website: http://www.americanlimetec.com LAST REVISED 2010-11-16 email: info@americanlimetec.com COPYRIGHT 2010 AMERICAN LIME TECHNOLOGY. telephone: 773.286.0566
  • 5. NH PC-01 COMMERCIAL CUT-AWAY WALL SECTION Typical Wall System: Standard Precast Concrete Wall Primed and Painted Interior Finish Gypsum Board Tape and Mud 5/8” Gypsum Board Vapor Barrier Fasteners at Gypsum Board Joint 2” Light Gauge Metal Furring Channels, 24” O.C. 2” Rigid Insulation Precast Concrete Wall Panel Precast Steel Rebar Reinforcement Grid Prime and Paint Coat Steel Rebar Reinforcement Grid (welded to Precast Wall Panel Rebar before Concrete Slab is Poured) Fluid-Applied Foundation Waterproofing Membrane (below grade) Insulative R-Value 7.5 Efficiency of Construction (# of Trades) 5 Approximate Wall Thickness 9” Embodied Carbon Dioxide Output* +11.4 in kilograms per square foot Recyclable or Biodegradable Content 66% Materials with Volatile Chemical Content 25% Approximate Cost Per Square Foot $29 The above figures are estimated with common building materials and practices, and are not specific to any single manufacturer. It reflects the performance of mid-wall conditions only and does not take into account floor, roof, corner, opening or mechanical conditions. *Source: Athena Institute and University of Minnesota, US Life Cycle Inventory Database, EcoCalculator for Assemblies. website: http://www.americanlimetec.com LAST REVISED 2010-11-16 email: info@americanlimetec.com COPYRIGHT 2010 AMERICAN LIME TECHNOLOGY. telephone: 773.286.0566
  • 6. NH BV-02 COMMERCIAL CUT-AWAY WALL SECTION Typical Wall System: Standard CMU Wall with Brick Veneer Primed and Painted Interior Finish Gypsum Board Gypsum Board Tape and Mud Vapor Barrier 3 5/8” Light-Gauge Metal Framing, 24” O.C. Batt Insulation Fasteners at Gypsum Board Joint CMU Wire Reinforcement 8” CMU (Concrete Masonry Unit) Brick Tie Air Barrier Wrap 2” Rigid Insulation Air Cavity Brick Veneer Mortar Net at Base of Air Cavity Flashing with Continuous Fastener Strip Weep Vent Stainless Steel Counterflashing Insulative R-Value 17.6 Efficiency of Construction (# of Trades) 5 Approximate Wall Thickness 18.5” Embodied Carbon Dioxide Output* +21.8 in kilograms per square foot Recyclable or Biodegradable Content 4% Materials with Volatile Chemical Content 35% Approximate Cost Per Square Foot $42 The above figures are estimated with common building materials and practices, and are not specific to any single manufacturer. It reflects the performance of mid-wall conditions only and does not take into account floor, roof, corner, opening or mechanical conditions. *Source: Athena Institute and University of Minnesota, US Life Cycle Inventory Database, EcoCalculator for Assemblies. website: http://www.americanlimetec.com LAST REVISED 2010-11-16 email: info@americanlimetec.com COPYRIGHT 2010 AMERICAN LIME TECHNOLOGY. telephone: 773.286.0566