2102-487
Industrial Electronics

Signal Conditioners
and Transmission
Overview

4-20 mA
Amp

V to I

I to V

Amp

Control Room

Field
Noise Source

Interference
Motor/Power

Arcing

Lighting
Instrumentation Amplifier (IA)
Instrumentation amplifiers a dedicate differential amplifier with extremely
high input impedance. Its gain can be precisely se by a single internal or
external resistor. The high common-mode rejection makes IA very useful
in recovering small signals buried in large common-mode offsets or
noise.
•IA consists of Two stages:
•The fist stage: high input impedance and gain control
•The second stage: differential amplifier (change differential signal to
common to ground
R-

R
E

+
R

-

R+∆R

+

Vdm/2

Vout

R

Vcm

+

-

-

+

Vdm/2

R+

Bridge circuit for sensor application

Equivalent circuit for a Load cell
IA: The First Stage
For Ideal op amp, no voltage difference
between the inverting and noninverting inputs

V1 = e1 and V2 = e2

+
-

e1

V1

V2

VRg = e1 − e2
e1 − e2
Vo
Rg
- This current must flow through all three
resistors because none of the current can flow
into the op amp inputs
+

IRg

Rg

The voltage across Rg

R

-

R

I Rg =

+

Vo = I R g (2 R + Rg )

Rg = gain setting resistor

 2R 

Vo = (e1 − e2 )1 +
 R 
g 


e2

• Changing Rg will inversely alter the output voltage.
IA: First + Second stage
The second stage of IA is a unit-gain differential amplifier
V1
+
e1
-

R1

R

+

R1

-

Vo1

Rg

-

e2

+

+
R1

R

R1

Vo

 2R 

Vo = (e2 − e1 )1 +
 R 
+
g 

-

Gain = 1 +

2R
Rg

V2

 2R 
Vo = −Vo1

Vo1 = (e1 − e2 )1 +
 R 
g 

Without loading effect, we can applied the direct multiplication for the cascade system
e1 − e2

 2R 
1 +

 R 
g 


Vo1

-1

 2R 

Vo = (e2 − e1 )1 +
 R 
g 

IA with Offset (Reference)
e1

+
R1

R2

V1
R2

-

Vo1

Rg

-

e2

R1

+

Sense

 2R 
 +V
Vo = (e2 − e1 )1 +
 R  ref
g 


Output

+
R2

Reference

Load

V2

R2
+V
Vref

 2R 

Vo1 = (e1 − e2 )1 +
 R 
g 


+

Vref

-V

Vo = −Vo1 + Vref
e1 − e2

 2R 
1 +

 R 
g 


Vo1

-1

+
Vref

 2R 
 +V
Vo = (e2 − e1 )1 +
 R  ref
g 

Commercial IA: AD524
Features:
Low Noise: 0.3 µVp-p 0.1 Hz to 10 Hz
Low Nonlinearity: 0.03% (G = 1)
High CMRR: 120 dB (G = 1000)
Low offset Voltage: 50 µV
Gain Bandwidth Product: 25 MHz
Programmable Gain of 1, 10, 100, 1000

AD524 Functional Block Diagram
 40000 
 ± 20%
G = 1 +

Rg 



Here Rg = 40, 404, 4.44 kΩ or external
resistor (connect: RG1 – RG2)
Commercial IA: AD524

Vb

Va
349Ω

Vout

Ex For the circuit, calculate Va, Vb, and Vout as well as the effect on the output of the 5V common-mode signal.
For a gain of 100, CMRR = 100 dB

Vb = 1 Vsupply = 5 V
2

349Ω


Va = 
10 V = 4.99285 V
 350Ω + 349Ω 

Vout = G (Va − Vb )
= 100(4.99285 V - 5 V) = -715 mV

Gdm
Gcm = 0.001
Gcm
GcmVcm = 0.001× 5 V = 5 mV

CMRR = 20 log

The common mode error is

5 mV
× 100% = 0.7%
715 mV
Commercial IA: AD524

Error Budget Analysis
To illustrate how instrumentation amplifier specification are applied, we will
now examine a typical case where an AD524 is required to amplify the output an
unbalance transducer. Figure above shows a differential transducer, unbalance by 100
Ω supplying a 0 to 20 mV signal to an AD524C. The output of the IA feeds a 14-bit A/D
converter with a 0 to 2 Voltage range. The operating temperature is 25oC to 85oC.
Therefore, the largest change in temperature ∆T within the operating range is from
ambient to +85oC (85oC - 25oC = 60oC)
Commercial IA: AD524
1000ppm = 0.1%
Zero and Span Circuits
The zero and span circuit adjust the output of a transducer to match the
levels you want to provide to the controller or display.
Ex. You may need a 0.01 mV/lb input to a digital panel meter, while the load cell
provides a 20 µV/lb reading with 18 mV output with no load.
Ex. A/D converter needs a 0- to 5-V signal, while the temperature transducer
output 2.48 to 3.90 V.

Vout

Sp
an

do
ub
le

Vout
l
na
i
r ig
O
a
Sp

a
nH

o
er
Z

lf

ed
ift
sh

ly
ve
ti
si
po

al
in
rig
O

Vin
o
er
Z

d
fte
i
sh

ly
ve
ti
ga
ne

Vin
Zero and Span: Inverting summer
±V
ein

Rf

ROS

eu1

R
R

Ri
Rcomp

-

+

eu2

+

Inverting summer
Rf
Rf
eu1 = −
ein −
V
Ri
ROS
eu 2 =

Compare this to the eq. of straight line

Rf
Ri

ein +

R/2

Inverting amplifier
eu 2 = −eu1

Rf
ROS

V

eout

m=

Rf

y = mx + b

Here y = eu2, x = ein, m = Rf/Ri and b = Rf/Ros V

b=

Rf
ROS

V

ein

Ri
Zero and Span: Instrument Amplifier
Ex When the temperature in a process is at its minimum, the sensor outputs 2.48 V.
At maximum temperature, it outputs 3.90 V. The A/D converter used to input these
data into a computer has the range 0 to 5 V. To provide maximum resolution, you
must zero and span the signal from the transducer so that it fills the entire range of
converter.
Vout = 0-5 V
Vin = 2.48-3.90 V

Vout

b=

Rf
ROS

V

m=

Rf
Ri

Vin

m=

Vout (max) − Vout (min)
5V−0V
=
= 3.52
Vin (max) − Vin (min) 3.9 V − 2.48 V

b = Vout − mVin = 0 − 3.52 × 2.48 V = -8.73 V

The gain, m is set by Rf/Ri , Rf relatively large, so that Ri
will not load down the sensors
R f 330 kΩ
Let Rf = 330 kΩ
Ri =
=
= 93.7 kΩ
m
3.52
Select Rs as a 47 kΩ fixed resistor with a series 100 kΩ potentiometer. (m ~ 2.25-7.02)
R f V (330 kΩ)(- 12V)
b is Rf/ROSV select V = -12 V
ROS =
=
= 454 kΩ
b
− 8.73 V
Select Rs as a 220 kΩ fixed resistor with a 500 kΩ potentiometer. (b ~ -18 - -5.5 V)

Rcomp = R f // R1 // ROS = 62.9 kΩ
Select Rcomp = 56 kΩ
The resistors in the 2nd stage should be in kΩ range, this will not load the 1st stage,
pick R = 2.2 kΩ and so R/2 = 1.1 kΩ
Zero and Span: Instrument Amplifier
+V

+
8
2
16

+
ein

4

+

5

13

Rg

-

AD524

1

R1

O

6

-

Rg

R

-

span

+V

Output

+

7

+V

Sense

R2

Vout

9

11
3

span

S
10

12

R2

-

R2

R1

Reference

R2

+

+V

-V

Vref

zero

Vref

zero

+

-

-

-V

-V

+

-V

 40000 
(e2 − e1 ) + Vref
Vout = 1 +

Rg 



Vref

Vout
Zero and Span: Instrument Amplifier
Ex The output from a load cell changes 20 µV/lb with an output of 18 mV with no
load on the cell. Design a zero and span converter using an instrumentation
amplifier which will output 0 Vdc when there is no load, and will change 10 mV/lb.
+V

Vsensor = 20µV/lb x Load + 18 mV
Vout = 10mV/lb x Load = G Vsensor+ Vref

8
2
16

+

4

+

5

13

Vsensor

Rg

S

3
1

span

Vout

9
6

11

-

O

10

AD524

12

-

Vout = 20µV G x Load + 18mV G + Vref

R

G=

7

+V
+V
-V

Vref

zero

G = 1+

ref

Vout

Rg = 80.2 Ω

40000
= 500
Rg

Select Rg as a 33 Ω fixed resistor with a series 100 Ω
potentiometer. (G ~ 301-1213)
Vref = −9 V
0 = 18 mVG + V = 18 mV × 500 + V

+
-

-V

10 mV/lb
= 500
20 µV/lb

-V

 40000 
(e2 − e1 ) + Vref
= 1 +

Rg 



ref

So tie one end of the potentiometer to ground and
the other end to –Vsupply. Select resistor and
potentiometer values that will put approximately -10 V
at one end and -8 V at the other end.
Voltage-To-Current Converters
Signal voltage transmission presents many problems. The series resistance
between the output of the signal conditioner and the load depends on the
distance, the wire used, temperature, conditioner.
Rwire ∝ Distance, wire type, temperature

Rwire

+
-

+

+
ein

-

R

Rf

 Rf 
ein
Vo = 1 +

R 


-

load



Load

 R + Load Vo

 wire

V To I: Floating Load
The most simple V to I actually is the non-inverting amplifier
+V
Rwire

+
+

load

-V

ein

-

I

+

ein
-

R

I

I=

ein
R

Therefore, The resistance in the transmission loop (Rloop = Rwire + Rload)
does not affect the transmitted current. However, the output voltage
of the op amp is affected by the Rloop
 Rloop 
ein < Vsat
Vout = 1 +

R 



Rloop must be kept small enough to keep the op amp out of the saturation.
V To I: Floating Load
V to I with current booster

Add transistor for
increase current
output

+V

New op amp with
high current output
+

Q1

-

I

Rwire

Q2
load

+
ein

-V

-

I

R

I=

ein
R

Many transmission standard call for either 20 or 60 mA current. These
values are beyond the capabilities of most general-purpose op amps.
However, the transistor can be added to increase the transmission current
capability.
V To I: Floating Load
The signal at the load is inherently differential. So we can use difference or
instrumentation amplifier to reject any common-mode noise.
Open and short circuit in the transmission loop can be detected by
checking Vout of the non-inverting amplifier (transmission side)
open circuit : Vout = Vsat
short circuit : Vout = ein
However, at the load side, with this circuit , if ein = 0, IL = 0, here it appears
that the IL = 0 is the valid signal. If the open or short circuit fault occurs, IL
will fall to zero too. The load would respond as if ein = 0.
Therefore a method has been advised to allow the load to differentiate
between no signal (circuit failure)
IL = 0 and ein = 0
This can be achieved by adding an offset to IL when ein = 0
ein = 0: IL > 0
Ex. 4-20 mA standard in current transimission
V To I: Floating Load
zero

+V

ein

10 kΩ

eref

An example of 4-20 mA V to I converter (span + zero adjust)
-V

+V

1 MΩ
+

Iin

-

1 MΩ

IL

Q1

load

-V

R span

I
b=

m=

1
2R

eref
2R

ein

Rwire

I=

ein + eref
2R

=

ein eref
+
2R 2R

m = 1/2R, b = eref/2R
Zero and Span: Instrument Amplifier
Ex Design an offset voltage-to-current converter that will produce 4 mA with an
input of -5 V and 20 mA with an input of 10 V
I (mA)

Vin = -5 - 10 V

20

m=

15
10

1
I (max) − I out (min) 20 mA − 4 mA
= out
=
2 R Vin (max) − Vin (min)
10 V − (−5 V)

R = 469 Ω

Select a 430 Ω fixed resistor with a series 100 Ω potentiometer.

5
-5

Iout = 4 - 20 mA

4
0

I=

5

Vin Vref
+
2R 2R

10

Vin

Vref = 2 RI − Vin = 2(469 Ω)(20 mA) − 10V = 8.8 V
V To I: Grounded Load
This V to I actually is a derivative of difference amplifier
R3
R1

I

+
e1

Vout

R2

e2

Rs

+

VL

R4

load

I

-

R1=R2=R3=R4=R

Using superposition:
Vout due to e1 = -e1
Vout due to e2 = e2
Vout due to VL = VL

Vout = Vout |e1 +Vout |e2 +Vout |VL
= - e1 + e2 + VL = e2 - e1 + VL

The current drive into the load is approximately equal to the current in Rs if RLoad << R2+R4

I L ≈ I Rs =
As in the case of the floating load:

Vout − VL e2 − e1
=
Rs
Rs

VSat > IRload + e2 − e1
V To I: Grounded Load
An example of 4-20 mA V to I converter (span + zero adjust)
zero

+V

Rb
eref

100 kΩ

-

Rs

+

100 kΩ

I

Ra

100 kΩ

span

ein

-V

+

VL

load

100 kΩ

IL ≈

I
m=

b=−

eref
Rs

ein

1
Rs

ein − eref
Rs

ein eref
=
−
Rs Rs

m = 1/R, b = -eref/R
V To I: XTR110
•4 to 20 mA Transmitter
•Selectable input/output ranges: 0-5V or 0-10V Inputs
4-20mA, 0-20mA, 5-25mA Outputs
• Required an external MOS transistor to transmit current to load
Reference voltage

I to I converter
(current mirror)

Precision resistive
network

V to I converter
V To I: XTR110
VCC 13.5-40V

XTR110

VIN1(10V)

16

R8
500Ω
4

Io/10
R1
15kΩ
R5

R2
5kΩ

-

Va
R4
10kΩ

Vb

Io

I R8 ≈ I R 6

14

+

+
-

Io
4-20mA

Io/10

R6
1562.5Ω
16mA
span
9

R7
6250Ω
4mA
span
10

8

Vb Va
=
R6 R6

The current IR6 is approximately
equal to IR8

3

R3
20kΩ

16.25kΩ

5

External
MOS

1

VREF IN 3

VIN2(5V)

R9
50Ω

I R6 =

Since there is no voltage
difference between the op
amp inputs
RL

VR 8 = VR 9
I o = I R9 =

Io =

I R 8 R8
= 10 I R 8
R9
10Va
R6
V To I: XTR110
The voltage at Va is defined by precision divider network and the
voltage at Vin1, Vin2 and Vref . Using superposition
Va due to Vin1 = Vin1/4
Va due to Vin2 = Vin2/2
Va due to Vref = Vref/16
Va = Vin1 / 4 + Vin 2 / 2 + Vref / 16

Therefore, the relation of the output current can be shown as
Io =

10(Vin1 / 4 + Vin 2 / 2 + Vref / 16)
Rspan

This IC allows us to change the value of Rspan by using R6, R7 and
external resistors so therefore the Io span can be set to 16mA, 4mA or
arbitrary value.
Ex if Vin2 = 0, Vref = 10 V, Vin1 varies from 0-10V and Use Rspan = R6 = 1562.5Ω
At Vin1 =0 V; Io = 4 mA at zero Vin1

Zero = 4 mA

At Vin1 =0 V; Io = 20 mA at Vin1 = 10 V

Zero+span = 4mA + 16 mA
V To I: XTR110
VIN1

4

VREF IN 3
R1
15kΩ

R3
20kΩ

R5

R2
5kΩ

1 + 2 + 3

Va

16.25kΩ
R4
10kΩ

1
Va = 1 VIN1 + 1 VIN2 + 16 VREF
4
2

VIN2
5

Rin = 22 kΩ

Rin = 27 kΩ

Rin = 20 kΩ

VIN2

VIN1

VREF IN

1

Va

16.25kΩ
R1
15kΩ

R2
5kΩ

R4
10kΩ

R4 //( R5 + R1 // R2 )
VIN1 = 1 VIN1
4
R3 + R4 //( R5 + R1 // R2 )

R1
15kΩ

R4
10kΩ
R5

R5

Va =

2

R3
20kΩ

Va =

R2
5kΩ

R5

Va

16.25kΩ
R1
15kΩ

Va

16.25kΩ
R2
5kΩ

R3
20kΩ

R3 //( R5 + R1 // R2 )
VIN2 = 1 VIN2
2
R4 + R3 //( R5 + R1 // R2 )

3

Va =

R4
10kΩ

R3
20kΩ

R3 // R4
R2
1
VREF = 16 VREF
( R5 + R1 // R2 ) + R3 // R4 R1 + R2
V To I: XTR110
Pin connections for standard XTR110 input voltage/output current ranges

15 V
1 µF
15
16
1

12

3

13

XTR110

14

4
5

9

A basic 4 to 20 mA transmitter
4 to 20 mA Out

2

0 to 10 V
RL

VL
V To I: XTR110
I out =

Vout = 400Vin + 6 V

Vsensor = ±10 mV

10(Vin1 / 4)
1250 Ω

I out = 4 − 20 mA

Vsensor = 2 − 10 V

I out =

10(400Vsensor + 6) / 4
1250 Ω
Current-To-Voltage Converters
Grounded Load I to V converter

Span and Zero circuit

Rf

Ros
±V

4 to
20 mA

R

+
-

R

R2

-

+

+

RL
Rcomp

Current is converted
into a voltage by RL

R/2

+
Vout
-

Voltage follower is inserted
to avoid the loading effect

Vout =

Rf
Ri

IRL +

Rf
ROS

V

m = RfRL/Ri, b = Rf/ROSV

The grounded load converter has many problems with the common ground (use by
many device) especially the noise source. To reduce this problem, we use a
floating load.
I To V Converters: Floating Load
Rf

4-20 mA

Rspan

Ri

R4
Ri

+
Vout
-

+

+V
Rf
Rpot

+

Vref

-V

Vout =

Rf
Ri

IRspan + Vref

m = RfRL/Ri, b = Vref

To prevent the loading effect be sure that Rspan << Ri
or Instrumentation amplifier can be used in stead
I To V Converters: Floating Load
Ex Design a floating current-to-voltage converter that will convert a 4- to 20-mA
current signal into 0- to 10-V ground-referenced voltage signal. If voltage-to-current
converter, has +V = 12 V, Rspan V-I =312 Ω, Imax = 20 mA What is the maximum
allowable Rspan I-V
Vout = 0-10 V
Iin = 4 - 20 mA

Vout =

Rf
Ri

IRspan + Vref

Rf
Ri

RspanI −V =

10 V − 0 V
Vout (max) − Vout (min)
=
= 625 Ω
20 mA − 4 mA
I in (max) − I in (min)

Choose Rf/Ri =10 This seem arbitrary now, but we’ll come to check it again

RspanI −V = 62.5 Ω
Since R i >> Rspan I-V, pick Ri = 2.2 kΩ
Find Vref :

Vref = Vout −

Rf
Ri

Rspan I = 0 −

Rf = 22 kΩ

22 kΩ
(4 mA )(62.5Ω ) = −2.5 V
2.2 kΩ
I To V Converters: Floating Load
+V

+

+

2V

+

-

0.7 V

-

I

+

IRspan I-V
-V
+

IRspan V-I

Rspan I-V

-

I

Rspan V-I

-

+ V = 2 + 0.7 + IRspanI −V + IRspanV − I
RspanI −V (max) =

12 − 2 − 0.7 − (20 mA)(312)
= 153 Ω
20 mA

Therefore, 62.5 Ω resistor would work. However, if we had chosen R f/Ri =1 then
Rspan I-V = 625 Ω, which is too large. The op Amp in the voltage-to-curren converter
would saturate before 20 mA would be reached.
Voltage-To-Frequency Converters
To provide the high noise immunity, digital transmission must be used.
V to F will convert the analog voltage from the sensor or signal conditioner to
a pulse train. The pulse width is constant but the frequency varies linearly
with the applied voltage

f ∝ Vin

Vin

V to F

fout

fout

Vin

Ideal V to F characteristics
V-To-F: LM131

LM131

Suitable for various applications:
precision V to F converter
simple low-cost circuits for A/D conversion
precision F to V converter
long-term integration
linear frequency modulation and demodulation
Voltage-To-Frequency Converters
Basic V to F block diagram
Rt
VCC

8
2

Ct
5

Switched
current
source

fo =

Vlogic

RS

RL

CL

Comparator
1

Vx

6

7
Input
V
voltage 1

Vin

+

3

One shot
timer

Frequency
output

4

a
b

t

Vx
t

Vout

t
fout

High Vin → high fout

Adjustment

Low Vin → low fout

Adjust

High Vin → high fout

t

Vin RS 1
2.09 V RL Rt Ct
Voltage-To-Frequency Converters
Rt
VCC

Ct

8

Determine
Iref

2

Determine the timer of one shot
TOS = 1.1Rt Ct

5
Switched
current
source

Vlogic

RS

RL

CL

Comparator
1

6

7
Input
V
voltage in

+

3

One shot
timer

Frequency
output

4

Phase I: Charge CL with Iref within the specific time TOS from the one shot timer.
At the end of this phase, VC reaches the value assigned as Vx
Phase II: CL discharge through Iref until VC is equal to Vin. The time in this phase is
defined as TII
We can found that 1/(TOS + TII) = f ∝ Vin
Voltage-To-Frequency Converters
Phase I: Charge CL with Iref within the specific time TOS determined from the one
shot timer. At the end of this phase, VC reaches the value assigned as Vx
Initial condition: VC(0) = Vin
Iref

RL

CL

VC (t ) = (Vin − I ref RL )e − t /τ + I ref RL

τ = RL C L

e −TOS /τ ≈ 1 − TOS / τ

Assume RLCL >> TOS

Vx = VC (TOS ) = Vin + (I ref RL − Vin )

TOS

1

τ

Phase II: CL discharge through Iref until VC is equal to Vin. The time in this phase is
defined as TII
Initial condition: VC(0) = Vx
RL

I

CL

τ = RL C L

VC (t ) = Vx e − t /τ
Vin = VC (TII ) = Vx e −TII /τ

TII = τ ln

Since RLCL >> TOS, Therefore Vx /Vin ~ 1

V

TII = τ  x − 1
V

 in 

Vx
Vin
ln

Vx Vx
≈
−1
Vin Vin

2
Voltage-To-Frequency Converters
Combine eq.(1) and (2)

T = TOS + TII =
f =

I ref RLTOS
Vin

1
Vin
=
T I ref RLTOS

Substitute Iref = 1.9 V/ Rs ,TOS = 1.1RtCt

f =

Vin Rs
Vin
Rs 1
=
1.9 V RL (1.1Rt Ct ) 2.09 V RL Rt Ct
V To F Converters
Ex Design a voltage-to-frequency converter that will output 20 kHz when the input
is 5 V.
At maximum frequency, the minimum period is
1
1
Tmin =
=
= 50 µs
f max 20 kHz
We have to set the pulse width no wider than about 80% of the minimum period,
otherwise, at the higher frequencies the pulse width may approach or exceed the
period, which will not work.
tlow = 1.1Rt Ct
pick Ct = 0.0047 µF (somewhat arbitrary, but suggested by manufacturer)

Rt =

tlow
(0.8)(50 µs ) = 7.7 kΩ
=
1.1Ct (1.1)(0.0047 µF)

pick Rt = 6.8 kΩ, since this is not a critical parameter, as long as it is not too
big. This give tlow = 35 µs. Pick RL = 100 KΩ.

Rs =

(2 V ) f 0 RL Rt Ct = (2 V )(20 kHz )(100 kΩ )(6.8 kΩ )(0.0047 µF) = 25.6 kΩ
Vin

5V

Select a 22 kΩ fixed resistor with a series 10 kΩ potentiometer.
Voltage-To-Frequency Converters
Low-pass filter

Simple V to F converter
From

fo =

Vin RS 1
2.09 V RL Rt Ct

I=

1.9 V
< 200 µA
RS

Manufacturer’s recommended, RL = 100 kΩ, Rt = 6.8 kΩ, Ct = 0.01 µF and RS = 14.2 kΩ
fo =

1 kHz
Vin
Volt
V To F Converters
Ex Design a voltage-to-frequency converter that will output 20 kHz when the input
is 5 V.
At maximum frequency, the minimum period is
1
1
Tmin =
=
= 50 µs
f max 20 kHz
We have to set the pulse width no wider than about 80% of the minimum period,
otherwise, at the higher frequencies the pulse width may approach or exceed the
period, which will not work.
tlow = 1.1Rt Ct
pick Ct = 0.0047 µF (somewhat arbitrary, but suggested by manufacturer)

Rt =

tlow
(0.8)(50 µs ) = 7.7 kΩ
=
1.1Ct (1.1)(0.0047 µF)

pick Rt = 6.8 kΩ, since this is not a critical parameter, as long as it is not too
big. This give tlow = 35 µs. Pick RL = 100 KΩ.

Rs =

(2 V ) f 0 RL Rt Ct = (2 V )(20 kHz )(100 kΩ )(6.8 kΩ )(0.0047 µF) = 25.6 kΩ
Vin

5V

Select a 22 kΩ fixed resistor with a series 10 kΩ potentiometer.
Frequency-To-Voltage Converters
VCC

Iout
1

RL

Connect to low
pass filter

Comparator
7

RD

8

+

One shot
timer

Rt
VCC

Ct

CD
Vin

Vin
Iout

i

T
The amplitude of pulse current output is
The average voltage output is
The average current output is

i=
I ave =

1.9 V
Rs

it 1.9 V × 1.1Rt Ct
=
T
RsT

Vave = I av e RL = 1.9 V ×1.1Rt Ct

RL
f in
Rs
Frequency-To-Voltage Converters

High pass filter
for input
frequency

Low pass filter
for output
current

Simple F to V converter
From

Vave = 1.9 V ×1.1Rt Ct

RL
f in
RS

RL = 100 kΩ, Rt = 6.8 kΩ, Ct = 0.01 µF and RS = 14.2 kΩ
Vave =

1V
f in
kHz
F To V Converters
Ex A reflective optical sensor is used to encode the velocity of a shaft. There are
six pieces of reflective tape. They are sized and positioned to produce a 50% duty
cycle wave. The maximum shaft speed is 3000 r/min. Design the frequency-tovoltage converter necessary to output 10 V at maximum shaft speed. Provide
filtering adequate to assure no more than 10% ripple at 100 r/min
The maximum frequency is

Tmin =
Select

f max =

6 counts 3000 rev 1 min
×
×
= 300 Hz
rev
min
60 s

1
Tpulse = 0.5Tmin = 1.67 ms
= 3.33 ms
300 Hz
Tout ( high ) ≤ 0.8Tmin = (0.8)(3.33 ms) = 2.664 ms

Select Ct = 0.33 µF

Rt =

tlow
(0.8)(50 µs ) = 7.7 kΩ
=
1.1Ct (1.1)(0.0047 µF)

pick Rt = 6.8 kΩ, This give tout(high) = 2.47 ms. We must set 5RDCD << 1.67 ms, so
pick RD = 10 kΩ.

5 RD C D ≤ (0.1)tout ( high )

C D ≤ 3.3 nF
F To V Converters
RL
f in
Rs
2 V × 1.1Rt Ct RL f in (2 V )(1.1)(6.8 kΩ )(0.33 µF)(100 kΩ )(300 Hz )
Rs =
=
= 14.8 kΩ
Vave
10 V
Vave = 2 V × 1.1Rt Ct

Select Rs as a 10 kΩ fixed resistor with a series 10 kΩ potentiometer.

i=

Check
At 100 r/min

1.9 V
1.9 V
=
= 135 µA < 200 µA
Rs
14.8 kΩ
f =

6 counts 100 rev 1 min
×
×
= 10 Hz
rev
min
60 s
Tpulse = 0.05 ms
= 0.1 s

1
10 Hz
Filtering is accomplished by RL and CF
Tmin =

For 10% ripple,

CF ≥ −

t
RL ln(0.9)

CF ≥ −

τ = RL C F

Vout = V pk e − t /τ

Vout
= 0 .9 ≥ e − t / R L C F
V pk
and, we have

97.53 ms
= 9.25 µF
(100 kΩ ) ln(0.9)

t = T10Hz − tout ( high ) = 100 ms - 2.47 ms = 97.53 ms
Select CF = 10 µF
Cabling
• Cables are important because they are the longest parts of the system
and therefore act as efficient antennas that pick up and/or radiate noise.
• There are three coupling mechanisms that can occur between fields
and cables, and between cables (crosstalk).
• Capacitive or electric coupling (interaction of electric field and
circuit)
• Inductive or magnetic coupling (interaction between of the magnetic
field of two circuits.
• Electromagnetic coupling or radiation (RF interference)
Magnetic Coupling
• When a current flows in a closed circuit, it produce a magnetic flux, φ
which is proportional to the current.

φ = LI

• When current flow in one circuit produces a flux in a second circuit,
there is a mutual inductance M12 between circuits 1 and 2

M 12 =

φ12
I1

φ12 ∝ the current, geometry, and orientation

• The voltage VN induced in circuit to 2 due to the current I1

VN = M

di
= jωM 12 I1
dt

Assume i varies sinusoidal with time

Magnetic coupling between two circuits
Magnetic Coupling
• Separate the sensitive, input signal condition from the other portions of
the electronics: Digital signal (high f), high power circuit, ac power (50
or 60 Hz line)
• place low level signal on the separate card
• board layout
• separate low level signal conduit or race way, from ac power line,
communication or digital cable conduits.
• Reduce loop area (twisted pair)
• Use magnetic shield (effective at high frequency)
Magnetic Coupling
Capacitive Coupling
• The potential different between two conductors generates a proportional
electric field. This will result in the redistribution or movement (current)
of charge by external voltage source

*The shield must be
grounded.

VN =

VN =

jωRC12
V1
1 + jωR(C12 + C2G + C2 S )

jωRC12
V1
1 + jωR(C12 + C2G )

Capacitive coupling between two
conductors

Capacitive coupling with shield
Grounding Problems
• Grounding is one of the primary ways of minimizing unwanted noise
and pick up. (also bad grounding can cause the serious problem of
interference)
• A well-designed system can provide the protection against unwanted
interference and emission, without any addition per-unit cost to the
product
• Grounds category:

safety grounds (earth ground)
signal grounds

A signal ground is normally defined as an equipotential point or plane that
serves as a reference potential for a circuit or system (can not be realized
in practical systems)
A signal ground (better definition) is a low-impedance path for current to
return to the source.
Ground System
Ground System can be divided into three categories.
single-point grounds
multipoint grounds
hybrid grounds (frequency dependence)
1

2

Series connection

3

1

2

3

Parallel connection

Two types of single-point grounding connection

1

2

3

Multipoint connection
Single-Point Ground System
1
R1

2
R2

I1

A

I1+ I2+ I3

I2+ I3

3
I2

B

R3
I3

VA = ( I1 + I 2 + I 3 ) R1
VB = V A + ( I 2 + I 3 ) R2

I3

VC = VA + VB + I 3 R3

C

A series ground system is undesirable from a noise standpoint but has the
advantage of simple wiring

1

3

VA = I1 R1
VB = I 2 R2

R1
I1

2

VC = I 3 R3

A
R2
I2

B
R3

C

I3

A parallel ground system provides good noise performance at low frequency
but is mechanical cumbersome.
Single-Point Ground System
Single Point Grounding System
Ex Calculate Va and Vb resulting from the input signal and from the effects of the
ground returns current under the following circumstances
(a) Actuator off, Ic = 5 mA, Ip = 20 mA, Ia = 0;
(b) Actuator on, Ic = 8 mA, Ip = 35 mA, Ia = 1 A;
The voltage, Vb is determined by the 40-mV input signal and any voltage developed
across the 50 mΩ resistance by the ground return current.

Vb = −

1 MΩ
 1 MΩ 
(40 mV) + 1 +
Va
10 kΩ
10 kΩ 


Where Va = (Ic+Ip+Ia)50mΩ
(a) Actuator off

Va = (5 mA + 20 mA + 0)(50 mΩ) = 1.25 mV
Vb = −(100)(40 mV) + (101)(1.25 mV) = −3.87 V

The error is about 3% compare to the correct value (-100)(40 mV) = -4 V
(b) Actuator on

Va = (5 mA + 20 mA + 1 A)(50 mΩ) = 52 mV
Vb = −(100)(40 mV) + (101)(52 mV) = 1.25 V

The large return current has raised the non-inverting input to 52 mV, and this
causes the unacceptable error.
Single-Point Ground System
Multiple-Point Ground System
Ground loops can occur when the multiple ground points are separated by a
large distance and connected to the ac power ground, or when low-level analog
circuits are used.

0-100 m
signal wiring
Control
Building

Plant
0-2000V
Ground difference
Multiple-Point Ground System
circuit
1

VN

circuit
2

Ground loop

VG

A ground loop between two circuits
VN

circuit
1

circuit
2

VG

A ground loop between two circuits can be broken
by inserting a common-mode choke
Multiple-Point Ground System
VN

circuit
1

circuit
2

VG

A ground loop between two circuits can be broken
by inserting a transformer
VN

circuit
1

circuit
2

VG

A ground loop between two circuits can be broken
by inserting an optical coupler
Isolation Amplifiers
General concepts: Isolation Amplifier provides three important advantages
over normal amplifiers.
Safety issues for some industrial and medical applications: signal
common isolation and common ground can be achieved
Extremely high common-mode voltage tolerance (in general amp
this is normally less than power supply)
Very low failure currents
Transformer-coupled Amplifiers

Symbol of transformer-coupled amp.

Block diagram of AD289 isolation amp
Optically Coupled Amplifiers
Transformer-coupled isolation amplifiers are expensive, bulky, bandwidth
limited and slow response.
Optically-coupled isolation amplifiers have less non-linear and isolation.
Optically Coupled Amplifiers

Symbol of optically coupled amp.
Simplified schematic diagram

I1 = I 2 =

Vin
RG

Vout = I 2 RK =

RK
Vin
RG

Contenu connexe

Tendances

Osilator kelompok 6
Osilator kelompok 6Osilator kelompok 6
Osilator kelompok 6
kemenag
 
Teori Medan Elektromagnet (3 - 4) perambatan_gelombangelektromagnetik
Teori Medan Elektromagnet (3 - 4) perambatan_gelombangelektromagnetikTeori Medan Elektromagnet (3 - 4) perambatan_gelombangelektromagnetik
Teori Medan Elektromagnet (3 - 4) perambatan_gelombangelektromagnetik
jayamartha
 
Laporan 2 penyearah gelombang penuh dengan beban tahanan murni
Laporan 2 penyearah gelombang penuh dengan beban tahanan murniLaporan 2 penyearah gelombang penuh dengan beban tahanan murni
Laporan 2 penyearah gelombang penuh dengan beban tahanan murni
ridwan35
 
Dasar control system dengan matlab
Dasar control system dengan matlabDasar control system dengan matlab
Dasar control system dengan matlab
adi_yus
 
perancangan filter BPF
perancangan filter BPFperancangan filter BPF
perancangan filter BPF
sofyah annisaa
 
Pengolahan Sinyal Digital - Slide week 4 - transformasi fourier sinyal waktu ...
Pengolahan Sinyal Digital - Slide week 4 - transformasi fourier sinyal waktu ...Pengolahan Sinyal Digital - Slide week 4 - transformasi fourier sinyal waktu ...
Pengolahan Sinyal Digital - Slide week 4 - transformasi fourier sinyal waktu ...
Beny Nugraha
 
Motor asinkron
Motor asinkronMotor asinkron
Motor asinkron
Kevin Adit
 

Tendances (20)

Tugas elektronika membaca dioda
Tugas elektronika membaca diodaTugas elektronika membaca dioda
Tugas elektronika membaca dioda
 
Osilator kelompok 6
Osilator kelompok 6Osilator kelompok 6
Osilator kelompok 6
 
Bab 7 rangkaian orde dua
Bab 7 rangkaian orde duaBab 7 rangkaian orde dua
Bab 7 rangkaian orde dua
 
7. instrumen volt meter dan ammeter
7. instrumen volt meter dan ammeter7. instrumen volt meter dan ammeter
7. instrumen volt meter dan ammeter
 
Regulasi Tegangan by Muhammad Kennedy Ginting
Regulasi Tegangan by Muhammad Kennedy GintingRegulasi Tegangan by Muhammad Kennedy Ginting
Regulasi Tegangan by Muhammad Kennedy Ginting
 
PCM (Pulse Code Modulation)
PCM (Pulse Code Modulation)PCM (Pulse Code Modulation)
PCM (Pulse Code Modulation)
 
Fluks listrik, hukum gauss, dan teorema divergensi.
Fluks listrik, hukum gauss, dan teorema divergensi.Fluks listrik, hukum gauss, dan teorema divergensi.
Fluks listrik, hukum gauss, dan teorema divergensi.
 
Laporan Modulo Counter
Laporan Modulo CounterLaporan Modulo Counter
Laporan Modulo Counter
 
Modul ajar dsp_2020-bab_4_sistem linear time invariant
Modul ajar dsp_2020-bab_4_sistem linear time invariantModul ajar dsp_2020-bab_4_sistem linear time invariant
Modul ajar dsp_2020-bab_4_sistem linear time invariant
 
Teori Medan Elektromagnet (3 - 4) perambatan_gelombangelektromagnetik
Teori Medan Elektromagnet (3 - 4) perambatan_gelombangelektromagnetikTeori Medan Elektromagnet (3 - 4) perambatan_gelombangelektromagnetik
Teori Medan Elektromagnet (3 - 4) perambatan_gelombangelektromagnetik
 
Laporan 2 penyearah gelombang penuh dengan beban tahanan murni
Laporan 2 penyearah gelombang penuh dengan beban tahanan murniLaporan 2 penyearah gelombang penuh dengan beban tahanan murni
Laporan 2 penyearah gelombang penuh dengan beban tahanan murni
 
Karakteristik transistor
Karakteristik transistorKarakteristik transistor
Karakteristik transistor
 
Dasar Sistem Pengaturan-Matlab
Dasar Sistem Pengaturan-MatlabDasar Sistem Pengaturan-Matlab
Dasar Sistem Pengaturan-Matlab
 
Dasar control system dengan matlab
Dasar control system dengan matlabDasar control system dengan matlab
Dasar control system dengan matlab
 
Soal soal adc 2
Soal soal adc 2Soal soal adc 2
Soal soal adc 2
 
perancangan filter BPF
perancangan filter BPFperancangan filter BPF
perancangan filter BPF
 
Lalporan Pembangkit gelombang segitiga
Lalporan Pembangkit gelombang segitigaLalporan Pembangkit gelombang segitiga
Lalporan Pembangkit gelombang segitiga
 
Pengolahan Sinyal Digital - Slide week 4 - transformasi fourier sinyal waktu ...
Pengolahan Sinyal Digital - Slide week 4 - transformasi fourier sinyal waktu ...Pengolahan Sinyal Digital - Slide week 4 - transformasi fourier sinyal waktu ...
Pengolahan Sinyal Digital - Slide week 4 - transformasi fourier sinyal waktu ...
 
Transistor
TransistorTransistor
Transistor
 
Motor asinkron
Motor asinkronMotor asinkron
Motor asinkron
 

Similaire à Sig con

Chapter 5 operational amplifier
Chapter 5 operational amplifierChapter 5 operational amplifier
Chapter 5 operational amplifier
Hattori Sidek
 
Components operational amplifiers
Components  operational amplifiersComponents  operational amplifiers
Components operational amplifiers
sld1950
 
Fundamentals of oprational Amplifiers.pptx
Fundamentals of oprational Amplifiers.pptxFundamentals of oprational Amplifiers.pptx
Fundamentals of oprational Amplifiers.pptx
adityaraj7711
 
HA17741 General Purpose Operational Amplifier
HA17741 General Purpose Operational AmplifierHA17741 General Purpose Operational Amplifier
HA17741 General Purpose Operational Amplifier
Yong Heui Cho
 

Similaire à Sig con (20)

Lic lab manual
Lic lab manualLic lab manual
Lic lab manual
 
Ajal op amp
Ajal op ampAjal op amp
Ajal op amp
 
UNIT-3 OPAMP.pptx
UNIT-3 OPAMP.pptxUNIT-3 OPAMP.pptx
UNIT-3 OPAMP.pptx
 
Chapter 5 operational amplifier
Chapter 5 operational amplifierChapter 5 operational amplifier
Chapter 5 operational amplifier
 
Ch2- OpAmps.pdf
Ch2- OpAmps.pdfCh2- OpAmps.pdf
Ch2- OpAmps.pdf
 
Components operational amplifiers
Components  operational amplifiersComponents  operational amplifiers
Components operational amplifiers
 
Ic apps lab_manual_jwfiles
Ic apps lab_manual_jwfilesIc apps lab_manual_jwfiles
Ic apps lab_manual_jwfiles
 
Op amp applications cw nonlinear applications
Op amp applications cw nonlinear applicationsOp amp applications cw nonlinear applications
Op amp applications cw nonlinear applications
 
Unit-6 ae 3rd sem by Prof Priyanka Jain.pptx
Unit-6 ae 3rd sem by Prof Priyanka Jain.pptxUnit-6 ae 3rd sem by Prof Priyanka Jain.pptx
Unit-6 ae 3rd sem by Prof Priyanka Jain.pptx
 
Operational Amplifier Part 1
Operational Amplifier Part 1Operational Amplifier Part 1
Operational Amplifier Part 1
 
Applications of op amps
Applications of op ampsApplications of op amps
Applications of op amps
 
Op amp
Op ampOp amp
Op amp
 
Peakdetector
PeakdetectorPeakdetector
Peakdetector
 
Oscillators
OscillatorsOscillators
Oscillators
 
operational amplifiers
operational amplifiersoperational amplifiers
operational amplifiers
 
Chapter 7: Operational Amplifier (Op-Amp)
Chapter 7: Operational Amplifier (Op-Amp)Chapter 7: Operational Amplifier (Op-Amp)
Chapter 7: Operational Amplifier (Op-Amp)
 
Fundamentals of oprational Amplifiers.pptx
Fundamentals of oprational Amplifiers.pptxFundamentals of oprational Amplifiers.pptx
Fundamentals of oprational Amplifiers.pptx
 
Lm 3915
Lm 3915Lm 3915
Lm 3915
 
Operational amplifiers
Operational amplifiersOperational amplifiers
Operational amplifiers
 
HA17741 General Purpose Operational Amplifier
HA17741 General Purpose Operational AmplifierHA17741 General Purpose Operational Amplifier
HA17741 General Purpose Operational Amplifier
 

Dernier

Modular Monolith - a Practical Alternative to Microservices @ Devoxx UK 2024
Modular Monolith - a Practical Alternative to Microservices @ Devoxx UK 2024Modular Monolith - a Practical Alternative to Microservices @ Devoxx UK 2024
Modular Monolith - a Practical Alternative to Microservices @ Devoxx UK 2024
Victor Rentea
 
Finding Java's Hidden Performance Traps @ DevoxxUK 2024
Finding Java's Hidden Performance Traps @ DevoxxUK 2024Finding Java's Hidden Performance Traps @ DevoxxUK 2024
Finding Java's Hidden Performance Traps @ DevoxxUK 2024
Victor Rentea
 
Cloud Frontiers: A Deep Dive into Serverless Spatial Data and FME
Cloud Frontiers:  A Deep Dive into Serverless Spatial Data and FMECloud Frontiers:  A Deep Dive into Serverless Spatial Data and FME
Cloud Frontiers: A Deep Dive into Serverless Spatial Data and FME
Safe Software
 
+971581248768>> SAFE AND ORIGINAL ABORTION PILLS FOR SALE IN DUBAI AND ABUDHA...
+971581248768>> SAFE AND ORIGINAL ABORTION PILLS FOR SALE IN DUBAI AND ABUDHA...+971581248768>> SAFE AND ORIGINAL ABORTION PILLS FOR SALE IN DUBAI AND ABUDHA...
+971581248768>> SAFE AND ORIGINAL ABORTION PILLS FOR SALE IN DUBAI AND ABUDHA...
?#DUbAI#??##{{(☎️+971_581248768%)**%*]'#abortion pills for sale in dubai@
 

Dernier (20)

Emergent Methods: Multi-lingual narrative tracking in the news - real-time ex...
Emergent Methods: Multi-lingual narrative tracking in the news - real-time ex...Emergent Methods: Multi-lingual narrative tracking in the news - real-time ex...
Emergent Methods: Multi-lingual narrative tracking in the news - real-time ex...
 
Repurposing LNG terminals for Hydrogen Ammonia: Feasibility and Cost Saving
Repurposing LNG terminals for Hydrogen Ammonia: Feasibility and Cost SavingRepurposing LNG terminals for Hydrogen Ammonia: Feasibility and Cost Saving
Repurposing LNG terminals for Hydrogen Ammonia: Feasibility and Cost Saving
 
Exploring Multimodal Embeddings with Milvus
Exploring Multimodal Embeddings with MilvusExploring Multimodal Embeddings with Milvus
Exploring Multimodal Embeddings with Milvus
 
FWD Group - Insurer Innovation Award 2024
FWD Group - Insurer Innovation Award 2024FWD Group - Insurer Innovation Award 2024
FWD Group - Insurer Innovation Award 2024
 
Modular Monolith - a Practical Alternative to Microservices @ Devoxx UK 2024
Modular Monolith - a Practical Alternative to Microservices @ Devoxx UK 2024Modular Monolith - a Practical Alternative to Microservices @ Devoxx UK 2024
Modular Monolith - a Practical Alternative to Microservices @ Devoxx UK 2024
 
ProductAnonymous-April2024-WinProductDiscovery-MelissaKlemke
ProductAnonymous-April2024-WinProductDiscovery-MelissaKlemkeProductAnonymous-April2024-WinProductDiscovery-MelissaKlemke
ProductAnonymous-April2024-WinProductDiscovery-MelissaKlemke
 
Biography Of Angeliki Cooney | Senior Vice President Life Sciences | Albany, ...
Biography Of Angeliki Cooney | Senior Vice President Life Sciences | Albany, ...Biography Of Angeliki Cooney | Senior Vice President Life Sciences | Albany, ...
Biography Of Angeliki Cooney | Senior Vice President Life Sciences | Albany, ...
 
MS Copilot expands with MS Graph connectors
MS Copilot expands with MS Graph connectorsMS Copilot expands with MS Graph connectors
MS Copilot expands with MS Graph connectors
 
Finding Java's Hidden Performance Traps @ DevoxxUK 2024
Finding Java's Hidden Performance Traps @ DevoxxUK 2024Finding Java's Hidden Performance Traps @ DevoxxUK 2024
Finding Java's Hidden Performance Traps @ DevoxxUK 2024
 
Cloud Frontiers: A Deep Dive into Serverless Spatial Data and FME
Cloud Frontiers:  A Deep Dive into Serverless Spatial Data and FMECloud Frontiers:  A Deep Dive into Serverless Spatial Data and FME
Cloud Frontiers: A Deep Dive into Serverless Spatial Data and FME
 
+971581248768>> SAFE AND ORIGINAL ABORTION PILLS FOR SALE IN DUBAI AND ABUDHA...
+971581248768>> SAFE AND ORIGINAL ABORTION PILLS FOR SALE IN DUBAI AND ABUDHA...+971581248768>> SAFE AND ORIGINAL ABORTION PILLS FOR SALE IN DUBAI AND ABUDHA...
+971581248768>> SAFE AND ORIGINAL ABORTION PILLS FOR SALE IN DUBAI AND ABUDHA...
 
[BuildWithAI] Introduction to Gemini.pdf
[BuildWithAI] Introduction to Gemini.pdf[BuildWithAI] Introduction to Gemini.pdf
[BuildWithAI] Introduction to Gemini.pdf
 
Rising Above_ Dubai Floods and the Fortitude of Dubai International Airport.pdf
Rising Above_ Dubai Floods and the Fortitude of Dubai International Airport.pdfRising Above_ Dubai Floods and the Fortitude of Dubai International Airport.pdf
Rising Above_ Dubai Floods and the Fortitude of Dubai International Airport.pdf
 
Apidays New York 2024 - The Good, the Bad and the Governed by David O'Neill, ...
Apidays New York 2024 - The Good, the Bad and the Governed by David O'Neill, ...Apidays New York 2024 - The Good, the Bad and the Governed by David O'Neill, ...
Apidays New York 2024 - The Good, the Bad and the Governed by David O'Neill, ...
 
CNIC Information System with Pakdata Cf In Pakistan
CNIC Information System with Pakdata Cf In PakistanCNIC Information System with Pakdata Cf In Pakistan
CNIC Information System with Pakdata Cf In Pakistan
 
AWS Community Day CPH - Three problems of Terraform
AWS Community Day CPH - Three problems of TerraformAWS Community Day CPH - Three problems of Terraform
AWS Community Day CPH - Three problems of Terraform
 
ICT role in 21st century education and its challenges
ICT role in 21st century education and its challengesICT role in 21st century education and its challenges
ICT role in 21st century education and its challenges
 
Exploring the Future Potential of AI-Enabled Smartphone Processors
Exploring the Future Potential of AI-Enabled Smartphone ProcessorsExploring the Future Potential of AI-Enabled Smartphone Processors
Exploring the Future Potential of AI-Enabled Smartphone Processors
 
MINDCTI Revenue Release Quarter One 2024
MINDCTI Revenue Release Quarter One 2024MINDCTI Revenue Release Quarter One 2024
MINDCTI Revenue Release Quarter One 2024
 
Navigating the Deluge_ Dubai Floods and the Resilience of Dubai International...
Navigating the Deluge_ Dubai Floods and the Resilience of Dubai International...Navigating the Deluge_ Dubai Floods and the Resilience of Dubai International...
Navigating the Deluge_ Dubai Floods and the Resilience of Dubai International...
 

Sig con

  • 2. Overview 4-20 mA Amp V to I I to V Amp Control Room Field Noise Source Interference Motor/Power Arcing Lighting
  • 3. Instrumentation Amplifier (IA) Instrumentation amplifiers a dedicate differential amplifier with extremely high input impedance. Its gain can be precisely se by a single internal or external resistor. The high common-mode rejection makes IA very useful in recovering small signals buried in large common-mode offsets or noise. •IA consists of Two stages: •The fist stage: high input impedance and gain control •The second stage: differential amplifier (change differential signal to common to ground R- R E + R - R+∆R + Vdm/2 Vout R Vcm + - - + Vdm/2 R+ Bridge circuit for sensor application Equivalent circuit for a Load cell
  • 4. IA: The First Stage For Ideal op amp, no voltage difference between the inverting and noninverting inputs V1 = e1 and V2 = e2 + - e1 V1 V2 VRg = e1 − e2 e1 − e2 Vo Rg - This current must flow through all three resistors because none of the current can flow into the op amp inputs + IRg Rg The voltage across Rg R - R I Rg = + Vo = I R g (2 R + Rg ) Rg = gain setting resistor  2R   Vo = (e1 − e2 )1 +  R  g   e2 • Changing Rg will inversely alter the output voltage.
  • 5. IA: First + Second stage The second stage of IA is a unit-gain differential amplifier V1 + e1 - R1 R + R1 - Vo1 Rg - e2 + + R1 R R1 Vo  2R   Vo = (e2 − e1 )1 +  R  + g   - Gain = 1 + 2R Rg V2  2R  Vo = −Vo1  Vo1 = (e1 − e2 )1 +  R  g   Without loading effect, we can applied the direct multiplication for the cascade system e1 − e2  2R  1 +   R  g   Vo1 -1  2R   Vo = (e2 − e1 )1 +  R  g  
  • 6. IA with Offset (Reference) e1 + R1 R2 V1 R2 - Vo1 Rg - e2 R1 + Sense  2R   +V Vo = (e2 − e1 )1 +  R  ref g   Output + R2 Reference Load V2 R2 +V Vref  2R   Vo1 = (e1 − e2 )1 +  R  g   + Vref -V Vo = −Vo1 + Vref e1 − e2  2R  1 +   R  g   Vo1 -1 + Vref  2R   +V Vo = (e2 − e1 )1 +  R  ref g  
  • 7. Commercial IA: AD524 Features: Low Noise: 0.3 µVp-p 0.1 Hz to 10 Hz Low Nonlinearity: 0.03% (G = 1) High CMRR: 120 dB (G = 1000) Low offset Voltage: 50 µV Gain Bandwidth Product: 25 MHz Programmable Gain of 1, 10, 100, 1000 AD524 Functional Block Diagram  40000   ± 20% G = 1 +  Rg    Here Rg = 40, 404, 4.44 kΩ or external resistor (connect: RG1 – RG2)
  • 8. Commercial IA: AD524 Vb Va 349Ω Vout Ex For the circuit, calculate Va, Vb, and Vout as well as the effect on the output of the 5V common-mode signal. For a gain of 100, CMRR = 100 dB Vb = 1 Vsupply = 5 V 2 349Ω   Va =  10 V = 4.99285 V  350Ω + 349Ω  Vout = G (Va − Vb ) = 100(4.99285 V - 5 V) = -715 mV Gdm Gcm = 0.001 Gcm GcmVcm = 0.001× 5 V = 5 mV CMRR = 20 log The common mode error is 5 mV × 100% = 0.7% 715 mV
  • 9. Commercial IA: AD524 Error Budget Analysis To illustrate how instrumentation amplifier specification are applied, we will now examine a typical case where an AD524 is required to amplify the output an unbalance transducer. Figure above shows a differential transducer, unbalance by 100 Ω supplying a 0 to 20 mV signal to an AD524C. The output of the IA feeds a 14-bit A/D converter with a 0 to 2 Voltage range. The operating temperature is 25oC to 85oC. Therefore, the largest change in temperature ∆T within the operating range is from ambient to +85oC (85oC - 25oC = 60oC)
  • 11. Zero and Span Circuits The zero and span circuit adjust the output of a transducer to match the levels you want to provide to the controller or display. Ex. You may need a 0.01 mV/lb input to a digital panel meter, while the load cell provides a 20 µV/lb reading with 18 mV output with no load. Ex. A/D converter needs a 0- to 5-V signal, while the temperature transducer output 2.48 to 3.90 V. Vout Sp an do ub le Vout l na i r ig O a Sp a nH o er Z lf ed ift sh ly ve ti si po al in rig O Vin o er Z d fte i sh ly ve ti ga ne Vin
  • 12. Zero and Span: Inverting summer ±V ein Rf ROS eu1 R R Ri Rcomp - + eu2 + Inverting summer Rf Rf eu1 = − ein − V Ri ROS eu 2 = Compare this to the eq. of straight line Rf Ri ein + R/2 Inverting amplifier eu 2 = −eu1 Rf ROS V eout m= Rf y = mx + b Here y = eu2, x = ein, m = Rf/Ri and b = Rf/Ros V b= Rf ROS V ein Ri
  • 13. Zero and Span: Instrument Amplifier Ex When the temperature in a process is at its minimum, the sensor outputs 2.48 V. At maximum temperature, it outputs 3.90 V. The A/D converter used to input these data into a computer has the range 0 to 5 V. To provide maximum resolution, you must zero and span the signal from the transducer so that it fills the entire range of converter. Vout = 0-5 V Vin = 2.48-3.90 V Vout b= Rf ROS V m= Rf Ri Vin m= Vout (max) − Vout (min) 5V−0V = = 3.52 Vin (max) − Vin (min) 3.9 V − 2.48 V b = Vout − mVin = 0 − 3.52 × 2.48 V = -8.73 V The gain, m is set by Rf/Ri , Rf relatively large, so that Ri will not load down the sensors R f 330 kΩ Let Rf = 330 kΩ Ri = = = 93.7 kΩ m 3.52 Select Rs as a 47 kΩ fixed resistor with a series 100 kΩ potentiometer. (m ~ 2.25-7.02) R f V (330 kΩ)(- 12V) b is Rf/ROSV select V = -12 V ROS = = = 454 kΩ b − 8.73 V Select Rs as a 220 kΩ fixed resistor with a 500 kΩ potentiometer. (b ~ -18 - -5.5 V) Rcomp = R f // R1 // ROS = 62.9 kΩ Select Rcomp = 56 kΩ The resistors in the 2nd stage should be in kΩ range, this will not load the 1st stage, pick R = 2.2 kΩ and so R/2 = 1.1 kΩ
  • 14. Zero and Span: Instrument Amplifier +V + 8 2 16 + ein 4 + 5 13 Rg - AD524 1 R1 O 6 - Rg R - span +V Output + 7 +V Sense R2 Vout 9 11 3 span S 10 12 R2 - R2 R1 Reference R2 + +V -V Vref zero Vref zero + - - -V -V + -V  40000  (e2 − e1 ) + Vref Vout = 1 +  Rg    Vref Vout
  • 15. Zero and Span: Instrument Amplifier Ex The output from a load cell changes 20 µV/lb with an output of 18 mV with no load on the cell. Design a zero and span converter using an instrumentation amplifier which will output 0 Vdc when there is no load, and will change 10 mV/lb. +V Vsensor = 20µV/lb x Load + 18 mV Vout = 10mV/lb x Load = G Vsensor+ Vref 8 2 16 + 4 + 5 13 Vsensor Rg S 3 1 span Vout 9 6 11 - O 10 AD524 12 - Vout = 20µV G x Load + 18mV G + Vref R G= 7 +V +V -V Vref zero G = 1+ ref Vout Rg = 80.2 Ω 40000 = 500 Rg Select Rg as a 33 Ω fixed resistor with a series 100 Ω potentiometer. (G ~ 301-1213) Vref = −9 V 0 = 18 mVG + V = 18 mV × 500 + V + - -V 10 mV/lb = 500 20 µV/lb -V  40000  (e2 − e1 ) + Vref = 1 +  Rg    ref So tie one end of the potentiometer to ground and the other end to –Vsupply. Select resistor and potentiometer values that will put approximately -10 V at one end and -8 V at the other end.
  • 16. Voltage-To-Current Converters Signal voltage transmission presents many problems. The series resistance between the output of the signal conditioner and the load depends on the distance, the wire used, temperature, conditioner. Rwire ∝ Distance, wire type, temperature Rwire + - + + ein - R Rf  Rf  ein Vo = 1 +  R    - load   Load   R + Load Vo   wire 
  • 17. V To I: Floating Load The most simple V to I actually is the non-inverting amplifier +V Rwire + + load -V ein - I + ein - R I I= ein R Therefore, The resistance in the transmission loop (Rloop = Rwire + Rload) does not affect the transmitted current. However, the output voltage of the op amp is affected by the Rloop  Rloop  ein < Vsat Vout = 1 +  R    Rloop must be kept small enough to keep the op amp out of the saturation.
  • 18. V To I: Floating Load V to I with current booster Add transistor for increase current output +V New op amp with high current output + Q1 - I Rwire Q2 load + ein -V - I R I= ein R Many transmission standard call for either 20 or 60 mA current. These values are beyond the capabilities of most general-purpose op amps. However, the transistor can be added to increase the transmission current capability.
  • 19. V To I: Floating Load The signal at the load is inherently differential. So we can use difference or instrumentation amplifier to reject any common-mode noise. Open and short circuit in the transmission loop can be detected by checking Vout of the non-inverting amplifier (transmission side) open circuit : Vout = Vsat short circuit : Vout = ein However, at the load side, with this circuit , if ein = 0, IL = 0, here it appears that the IL = 0 is the valid signal. If the open or short circuit fault occurs, IL will fall to zero too. The load would respond as if ein = 0. Therefore a method has been advised to allow the load to differentiate between no signal (circuit failure) IL = 0 and ein = 0 This can be achieved by adding an offset to IL when ein = 0 ein = 0: IL > 0 Ex. 4-20 mA standard in current transimission
  • 20. V To I: Floating Load zero +V ein 10 kΩ eref An example of 4-20 mA V to I converter (span + zero adjust) -V +V 1 MΩ + Iin - 1 MΩ IL Q1 load -V R span I b= m= 1 2R eref 2R ein Rwire I= ein + eref 2R = ein eref + 2R 2R m = 1/2R, b = eref/2R
  • 21. Zero and Span: Instrument Amplifier Ex Design an offset voltage-to-current converter that will produce 4 mA with an input of -5 V and 20 mA with an input of 10 V I (mA) Vin = -5 - 10 V 20 m= 15 10 1 I (max) − I out (min) 20 mA − 4 mA = out = 2 R Vin (max) − Vin (min) 10 V − (−5 V) R = 469 Ω Select a 430 Ω fixed resistor with a series 100 Ω potentiometer. 5 -5 Iout = 4 - 20 mA 4 0 I= 5 Vin Vref + 2R 2R 10 Vin Vref = 2 RI − Vin = 2(469 Ω)(20 mA) − 10V = 8.8 V
  • 22. V To I: Grounded Load This V to I actually is a derivative of difference amplifier R3 R1 I + e1 Vout R2 e2 Rs + VL R4 load I - R1=R2=R3=R4=R Using superposition: Vout due to e1 = -e1 Vout due to e2 = e2 Vout due to VL = VL Vout = Vout |e1 +Vout |e2 +Vout |VL = - e1 + e2 + VL = e2 - e1 + VL The current drive into the load is approximately equal to the current in Rs if RLoad << R2+R4 I L ≈ I Rs = As in the case of the floating load: Vout − VL e2 − e1 = Rs Rs VSat > IRload + e2 − e1
  • 23. V To I: Grounded Load An example of 4-20 mA V to I converter (span + zero adjust) zero +V Rb eref 100 kΩ - Rs + 100 kΩ I Ra 100 kΩ span ein -V + VL load 100 kΩ IL ≈ I m= b=− eref Rs ein 1 Rs ein − eref Rs ein eref = − Rs Rs m = 1/R, b = -eref/R
  • 24. V To I: XTR110 •4 to 20 mA Transmitter •Selectable input/output ranges: 0-5V or 0-10V Inputs 4-20mA, 0-20mA, 5-25mA Outputs • Required an external MOS transistor to transmit current to load Reference voltage I to I converter (current mirror) Precision resistive network V to I converter
  • 25. V To I: XTR110 VCC 13.5-40V XTR110 VIN1(10V) 16 R8 500Ω 4 Io/10 R1 15kΩ R5 R2 5kΩ - Va R4 10kΩ Vb Io I R8 ≈ I R 6 14 + + - Io 4-20mA Io/10 R6 1562.5Ω 16mA span 9 R7 6250Ω 4mA span 10 8 Vb Va = R6 R6 The current IR6 is approximately equal to IR8 3 R3 20kΩ 16.25kΩ 5 External MOS 1 VREF IN 3 VIN2(5V) R9 50Ω I R6 = Since there is no voltage difference between the op amp inputs RL VR 8 = VR 9 I o = I R9 = Io = I R 8 R8 = 10 I R 8 R9 10Va R6
  • 26. V To I: XTR110 The voltage at Va is defined by precision divider network and the voltage at Vin1, Vin2 and Vref . Using superposition Va due to Vin1 = Vin1/4 Va due to Vin2 = Vin2/2 Va due to Vref = Vref/16 Va = Vin1 / 4 + Vin 2 / 2 + Vref / 16 Therefore, the relation of the output current can be shown as Io = 10(Vin1 / 4 + Vin 2 / 2 + Vref / 16) Rspan This IC allows us to change the value of Rspan by using R6, R7 and external resistors so therefore the Io span can be set to 16mA, 4mA or arbitrary value. Ex if Vin2 = 0, Vref = 10 V, Vin1 varies from 0-10V and Use Rspan = R6 = 1562.5Ω At Vin1 =0 V; Io = 4 mA at zero Vin1 Zero = 4 mA At Vin1 =0 V; Io = 20 mA at Vin1 = 10 V Zero+span = 4mA + 16 mA
  • 27. V To I: XTR110 VIN1 4 VREF IN 3 R1 15kΩ R3 20kΩ R5 R2 5kΩ 1 + 2 + 3 Va 16.25kΩ R4 10kΩ 1 Va = 1 VIN1 + 1 VIN2 + 16 VREF 4 2 VIN2 5 Rin = 22 kΩ Rin = 27 kΩ Rin = 20 kΩ VIN2 VIN1 VREF IN 1 Va 16.25kΩ R1 15kΩ R2 5kΩ R4 10kΩ R4 //( R5 + R1 // R2 ) VIN1 = 1 VIN1 4 R3 + R4 //( R5 + R1 // R2 ) R1 15kΩ R4 10kΩ R5 R5 Va = 2 R3 20kΩ Va = R2 5kΩ R5 Va 16.25kΩ R1 15kΩ Va 16.25kΩ R2 5kΩ R3 20kΩ R3 //( R5 + R1 // R2 ) VIN2 = 1 VIN2 2 R4 + R3 //( R5 + R1 // R2 ) 3 Va = R4 10kΩ R3 20kΩ R3 // R4 R2 1 VREF = 16 VREF ( R5 + R1 // R2 ) + R3 // R4 R1 + R2
  • 28. V To I: XTR110 Pin connections for standard XTR110 input voltage/output current ranges 15 V 1 µF 15 16 1 12 3 13 XTR110 14 4 5 9 A basic 4 to 20 mA transmitter 4 to 20 mA Out 2 0 to 10 V RL VL
  • 29. V To I: XTR110 I out = Vout = 400Vin + 6 V Vsensor = ±10 mV 10(Vin1 / 4) 1250 Ω I out = 4 − 20 mA Vsensor = 2 − 10 V I out = 10(400Vsensor + 6) / 4 1250 Ω
  • 30. Current-To-Voltage Converters Grounded Load I to V converter Span and Zero circuit Rf Ros ±V 4 to 20 mA R + - R R2 - + + RL Rcomp Current is converted into a voltage by RL R/2 + Vout - Voltage follower is inserted to avoid the loading effect Vout = Rf Ri IRL + Rf ROS V m = RfRL/Ri, b = Rf/ROSV The grounded load converter has many problems with the common ground (use by many device) especially the noise source. To reduce this problem, we use a floating load.
  • 31. I To V Converters: Floating Load Rf 4-20 mA Rspan Ri R4 Ri + Vout - + +V Rf Rpot + Vref -V Vout = Rf Ri IRspan + Vref m = RfRL/Ri, b = Vref To prevent the loading effect be sure that Rspan << Ri or Instrumentation amplifier can be used in stead
  • 32. I To V Converters: Floating Load Ex Design a floating current-to-voltage converter that will convert a 4- to 20-mA current signal into 0- to 10-V ground-referenced voltage signal. If voltage-to-current converter, has +V = 12 V, Rspan V-I =312 Ω, Imax = 20 mA What is the maximum allowable Rspan I-V Vout = 0-10 V Iin = 4 - 20 mA Vout = Rf Ri IRspan + Vref Rf Ri RspanI −V = 10 V − 0 V Vout (max) − Vout (min) = = 625 Ω 20 mA − 4 mA I in (max) − I in (min) Choose Rf/Ri =10 This seem arbitrary now, but we’ll come to check it again RspanI −V = 62.5 Ω Since R i >> Rspan I-V, pick Ri = 2.2 kΩ Find Vref : Vref = Vout − Rf Ri Rspan I = 0 − Rf = 22 kΩ 22 kΩ (4 mA )(62.5Ω ) = −2.5 V 2.2 kΩ
  • 33. I To V Converters: Floating Load +V + + 2V + - 0.7 V - I + IRspan I-V -V + IRspan V-I Rspan I-V - I Rspan V-I - + V = 2 + 0.7 + IRspanI −V + IRspanV − I RspanI −V (max) = 12 − 2 − 0.7 − (20 mA)(312) = 153 Ω 20 mA Therefore, 62.5 Ω resistor would work. However, if we had chosen R f/Ri =1 then Rspan I-V = 625 Ω, which is too large. The op Amp in the voltage-to-curren converter would saturate before 20 mA would be reached.
  • 34. Voltage-To-Frequency Converters To provide the high noise immunity, digital transmission must be used. V to F will convert the analog voltage from the sensor or signal conditioner to a pulse train. The pulse width is constant but the frequency varies linearly with the applied voltage f ∝ Vin Vin V to F fout fout Vin Ideal V to F characteristics
  • 35. V-To-F: LM131 LM131 Suitable for various applications: precision V to F converter simple low-cost circuits for A/D conversion precision F to V converter long-term integration linear frequency modulation and demodulation
  • 36. Voltage-To-Frequency Converters Basic V to F block diagram Rt VCC 8 2 Ct 5 Switched current source fo = Vlogic RS RL CL Comparator 1 Vx 6 7 Input V voltage 1 Vin + 3 One shot timer Frequency output 4 a b t Vx t Vout t fout High Vin → high fout Adjustment Low Vin → low fout Adjust High Vin → high fout t Vin RS 1 2.09 V RL Rt Ct
  • 37. Voltage-To-Frequency Converters Rt VCC Ct 8 Determine Iref 2 Determine the timer of one shot TOS = 1.1Rt Ct 5 Switched current source Vlogic RS RL CL Comparator 1 6 7 Input V voltage in + 3 One shot timer Frequency output 4 Phase I: Charge CL with Iref within the specific time TOS from the one shot timer. At the end of this phase, VC reaches the value assigned as Vx Phase II: CL discharge through Iref until VC is equal to Vin. The time in this phase is defined as TII We can found that 1/(TOS + TII) = f ∝ Vin
  • 38. Voltage-To-Frequency Converters Phase I: Charge CL with Iref within the specific time TOS determined from the one shot timer. At the end of this phase, VC reaches the value assigned as Vx Initial condition: VC(0) = Vin Iref RL CL VC (t ) = (Vin − I ref RL )e − t /τ + I ref RL τ = RL C L e −TOS /τ ≈ 1 − TOS / τ Assume RLCL >> TOS Vx = VC (TOS ) = Vin + (I ref RL − Vin ) TOS 1 τ Phase II: CL discharge through Iref until VC is equal to Vin. The time in this phase is defined as TII Initial condition: VC(0) = Vx RL I CL τ = RL C L VC (t ) = Vx e − t /τ Vin = VC (TII ) = Vx e −TII /τ TII = τ ln Since RLCL >> TOS, Therefore Vx /Vin ~ 1 V  TII = τ  x − 1 V   in  Vx Vin ln Vx Vx ≈ −1 Vin Vin 2
  • 39. Voltage-To-Frequency Converters Combine eq.(1) and (2) T = TOS + TII = f = I ref RLTOS Vin 1 Vin = T I ref RLTOS Substitute Iref = 1.9 V/ Rs ,TOS = 1.1RtCt f = Vin Rs Vin Rs 1 = 1.9 V RL (1.1Rt Ct ) 2.09 V RL Rt Ct
  • 40. V To F Converters Ex Design a voltage-to-frequency converter that will output 20 kHz when the input is 5 V. At maximum frequency, the minimum period is 1 1 Tmin = = = 50 µs f max 20 kHz We have to set the pulse width no wider than about 80% of the minimum period, otherwise, at the higher frequencies the pulse width may approach or exceed the period, which will not work. tlow = 1.1Rt Ct pick Ct = 0.0047 µF (somewhat arbitrary, but suggested by manufacturer) Rt = tlow (0.8)(50 µs ) = 7.7 kΩ = 1.1Ct (1.1)(0.0047 µF) pick Rt = 6.8 kΩ, since this is not a critical parameter, as long as it is not too big. This give tlow = 35 µs. Pick RL = 100 KΩ. Rs = (2 V ) f 0 RL Rt Ct = (2 V )(20 kHz )(100 kΩ )(6.8 kΩ )(0.0047 µF) = 25.6 kΩ Vin 5V Select a 22 kΩ fixed resistor with a series 10 kΩ potentiometer.
  • 41. Voltage-To-Frequency Converters Low-pass filter Simple V to F converter From fo = Vin RS 1 2.09 V RL Rt Ct I= 1.9 V < 200 µA RS Manufacturer’s recommended, RL = 100 kΩ, Rt = 6.8 kΩ, Ct = 0.01 µF and RS = 14.2 kΩ fo = 1 kHz Vin Volt
  • 42. V To F Converters Ex Design a voltage-to-frequency converter that will output 20 kHz when the input is 5 V. At maximum frequency, the minimum period is 1 1 Tmin = = = 50 µs f max 20 kHz We have to set the pulse width no wider than about 80% of the minimum period, otherwise, at the higher frequencies the pulse width may approach or exceed the period, which will not work. tlow = 1.1Rt Ct pick Ct = 0.0047 µF (somewhat arbitrary, but suggested by manufacturer) Rt = tlow (0.8)(50 µs ) = 7.7 kΩ = 1.1Ct (1.1)(0.0047 µF) pick Rt = 6.8 kΩ, since this is not a critical parameter, as long as it is not too big. This give tlow = 35 µs. Pick RL = 100 KΩ. Rs = (2 V ) f 0 RL Rt Ct = (2 V )(20 kHz )(100 kΩ )(6.8 kΩ )(0.0047 µF) = 25.6 kΩ Vin 5V Select a 22 kΩ fixed resistor with a series 10 kΩ potentiometer.
  • 43. Frequency-To-Voltage Converters VCC Iout 1 RL Connect to low pass filter Comparator 7 RD 8 + One shot timer Rt VCC Ct CD Vin Vin Iout i T The amplitude of pulse current output is The average voltage output is The average current output is i= I ave = 1.9 V Rs it 1.9 V × 1.1Rt Ct = T RsT Vave = I av e RL = 1.9 V ×1.1Rt Ct RL f in Rs
  • 44. Frequency-To-Voltage Converters High pass filter for input frequency Low pass filter for output current Simple F to V converter From Vave = 1.9 V ×1.1Rt Ct RL f in RS RL = 100 kΩ, Rt = 6.8 kΩ, Ct = 0.01 µF and RS = 14.2 kΩ Vave = 1V f in kHz
  • 45. F To V Converters Ex A reflective optical sensor is used to encode the velocity of a shaft. There are six pieces of reflective tape. They are sized and positioned to produce a 50% duty cycle wave. The maximum shaft speed is 3000 r/min. Design the frequency-tovoltage converter necessary to output 10 V at maximum shaft speed. Provide filtering adequate to assure no more than 10% ripple at 100 r/min The maximum frequency is Tmin = Select f max = 6 counts 3000 rev 1 min × × = 300 Hz rev min 60 s 1 Tpulse = 0.5Tmin = 1.67 ms = 3.33 ms 300 Hz Tout ( high ) ≤ 0.8Tmin = (0.8)(3.33 ms) = 2.664 ms Select Ct = 0.33 µF Rt = tlow (0.8)(50 µs ) = 7.7 kΩ = 1.1Ct (1.1)(0.0047 µF) pick Rt = 6.8 kΩ, This give tout(high) = 2.47 ms. We must set 5RDCD << 1.67 ms, so pick RD = 10 kΩ. 5 RD C D ≤ (0.1)tout ( high ) C D ≤ 3.3 nF
  • 46. F To V Converters RL f in Rs 2 V × 1.1Rt Ct RL f in (2 V )(1.1)(6.8 kΩ )(0.33 µF)(100 kΩ )(300 Hz ) Rs = = = 14.8 kΩ Vave 10 V Vave = 2 V × 1.1Rt Ct Select Rs as a 10 kΩ fixed resistor with a series 10 kΩ potentiometer. i= Check At 100 r/min 1.9 V 1.9 V = = 135 µA < 200 µA Rs 14.8 kΩ f = 6 counts 100 rev 1 min × × = 10 Hz rev min 60 s Tpulse = 0.05 ms = 0.1 s 1 10 Hz Filtering is accomplished by RL and CF Tmin = For 10% ripple, CF ≥ − t RL ln(0.9) CF ≥ − τ = RL C F Vout = V pk e − t /τ Vout = 0 .9 ≥ e − t / R L C F V pk and, we have 97.53 ms = 9.25 µF (100 kΩ ) ln(0.9) t = T10Hz − tout ( high ) = 100 ms - 2.47 ms = 97.53 ms Select CF = 10 µF
  • 47. Cabling • Cables are important because they are the longest parts of the system and therefore act as efficient antennas that pick up and/or radiate noise. • There are three coupling mechanisms that can occur between fields and cables, and between cables (crosstalk). • Capacitive or electric coupling (interaction of electric field and circuit) • Inductive or magnetic coupling (interaction between of the magnetic field of two circuits. • Electromagnetic coupling or radiation (RF interference)
  • 48. Magnetic Coupling • When a current flows in a closed circuit, it produce a magnetic flux, φ which is proportional to the current. φ = LI • When current flow in one circuit produces a flux in a second circuit, there is a mutual inductance M12 between circuits 1 and 2 M 12 = φ12 I1 φ12 ∝ the current, geometry, and orientation • The voltage VN induced in circuit to 2 due to the current I1 VN = M di = jωM 12 I1 dt Assume i varies sinusoidal with time Magnetic coupling between two circuits
  • 49. Magnetic Coupling • Separate the sensitive, input signal condition from the other portions of the electronics: Digital signal (high f), high power circuit, ac power (50 or 60 Hz line) • place low level signal on the separate card • board layout • separate low level signal conduit or race way, from ac power line, communication or digital cable conduits. • Reduce loop area (twisted pair) • Use magnetic shield (effective at high frequency)
  • 51. Capacitive Coupling • The potential different between two conductors generates a proportional electric field. This will result in the redistribution or movement (current) of charge by external voltage source *The shield must be grounded. VN = VN = jωRC12 V1 1 + jωR(C12 + C2G + C2 S ) jωRC12 V1 1 + jωR(C12 + C2G ) Capacitive coupling between two conductors Capacitive coupling with shield
  • 52. Grounding Problems • Grounding is one of the primary ways of minimizing unwanted noise and pick up. (also bad grounding can cause the serious problem of interference) • A well-designed system can provide the protection against unwanted interference and emission, without any addition per-unit cost to the product • Grounds category: safety grounds (earth ground) signal grounds A signal ground is normally defined as an equipotential point or plane that serves as a reference potential for a circuit or system (can not be realized in practical systems) A signal ground (better definition) is a low-impedance path for current to return to the source.
  • 53. Ground System Ground System can be divided into three categories. single-point grounds multipoint grounds hybrid grounds (frequency dependence) 1 2 Series connection 3 1 2 3 Parallel connection Two types of single-point grounding connection 1 2 3 Multipoint connection
  • 54. Single-Point Ground System 1 R1 2 R2 I1 A I1+ I2+ I3 I2+ I3 3 I2 B R3 I3 VA = ( I1 + I 2 + I 3 ) R1 VB = V A + ( I 2 + I 3 ) R2 I3 VC = VA + VB + I 3 R3 C A series ground system is undesirable from a noise standpoint but has the advantage of simple wiring 1 3 VA = I1 R1 VB = I 2 R2 R1 I1 2 VC = I 3 R3 A R2 I2 B R3 C I3 A parallel ground system provides good noise performance at low frequency but is mechanical cumbersome.
  • 56. Single Point Grounding System Ex Calculate Va and Vb resulting from the input signal and from the effects of the ground returns current under the following circumstances (a) Actuator off, Ic = 5 mA, Ip = 20 mA, Ia = 0; (b) Actuator on, Ic = 8 mA, Ip = 35 mA, Ia = 1 A; The voltage, Vb is determined by the 40-mV input signal and any voltage developed across the 50 mΩ resistance by the ground return current. Vb = − 1 MΩ  1 MΩ  (40 mV) + 1 + Va 10 kΩ 10 kΩ   Where Va = (Ic+Ip+Ia)50mΩ (a) Actuator off Va = (5 mA + 20 mA + 0)(50 mΩ) = 1.25 mV Vb = −(100)(40 mV) + (101)(1.25 mV) = −3.87 V The error is about 3% compare to the correct value (-100)(40 mV) = -4 V (b) Actuator on Va = (5 mA + 20 mA + 1 A)(50 mΩ) = 52 mV Vb = −(100)(40 mV) + (101)(52 mV) = 1.25 V The large return current has raised the non-inverting input to 52 mV, and this causes the unacceptable error.
  • 58. Multiple-Point Ground System Ground loops can occur when the multiple ground points are separated by a large distance and connected to the ac power ground, or when low-level analog circuits are used. 0-100 m signal wiring Control Building Plant 0-2000V Ground difference
  • 59. Multiple-Point Ground System circuit 1 VN circuit 2 Ground loop VG A ground loop between two circuits VN circuit 1 circuit 2 VG A ground loop between two circuits can be broken by inserting a common-mode choke
  • 60. Multiple-Point Ground System VN circuit 1 circuit 2 VG A ground loop between two circuits can be broken by inserting a transformer VN circuit 1 circuit 2 VG A ground loop between two circuits can be broken by inserting an optical coupler
  • 61. Isolation Amplifiers General concepts: Isolation Amplifier provides three important advantages over normal amplifiers. Safety issues for some industrial and medical applications: signal common isolation and common ground can be achieved Extremely high common-mode voltage tolerance (in general amp this is normally less than power supply) Very low failure currents
  • 62. Transformer-coupled Amplifiers Symbol of transformer-coupled amp. Block diagram of AD289 isolation amp
  • 63. Optically Coupled Amplifiers Transformer-coupled isolation amplifiers are expensive, bulky, bandwidth limited and slow response. Optically-coupled isolation amplifiers have less non-linear and isolation.
  • 64. Optically Coupled Amplifiers Symbol of optically coupled amp. Simplified schematic diagram I1 = I 2 = Vin RG Vout = I 2 RK = RK Vin RG