Fanuc 16i 18i Alarms Codes 
You can Join at Our Group 
Facebook : CNC INDONESIA or Email :soekarno.gempar@gmail 
Fanuc 16i 18i Alarms Codes for CNC machinists. 
These Fanuc alarm code applies to following Fanuc CNC controls 
 Fanuc 16i/18i Model A 
 Fanuc 16i/18i Model B 
 Fanuc 16iLModel A 
 Fanuc 16iP Model A 
 Fanuc 16iP/18iP Model B 
FANUC 18i-MB 
Contents 
 Fanuc 16i 18i Alarms 
o Program errors (P/S alarm) 
o Laser alarms 
o Background edit alarm 
o Absolute pulse coder (APC) alarms 
o Serial pulse coder (SPC) alarms 
o Servo alarms 
o Over travel alarms 
o Overheat alarms
o Rigid tapping alarms 
o Serial Spindle alarms 
o Safety zone alarms 
o System alarms 
Fanuc 16i 18i Alarms
Program errors (P/S alarm) 
 0 PLEASE TURN OFF POWER 
 1 TH PARITY ALARM 
 2 TV PARITY ALARM 
 3 TOO MANY DIGITS 
 4 ADDRESS NOT FOUND 
 5 NO DATA AFTER ADDRESS 
 6 ILLEGAL USE OF NEGATIVE SIGN 
 7 ILLEGAL USE OF DECIMAL POINT 
 9 ILLEGAL ADDRESS INPUT 
 10 IMPROPER G–CODE 
 11 NO FEEDRATE COMMANDED 
 14 CAN NOT COMMAND G95 (M series) 
 14 ILLEGAL LEAD COMMAND (T series) 
 15 TOO MANY AXES COMMANDED (M series) 
 15 TOO MANY AXES COMMANDED (T series) 
 20 OVER TOLERANCE OF RADIUS 
 21 ILLEGAL PLANE AXIS COMMANDED 
 22 NO CIRCLE RADIUS 
 23 ILLEGAL RADIUS COMMAND (T series) 
 25 CANNOT COMMAND F0 IN G02/G03 (M series) 
 27 NO AXES COMMANDED IN G43/G44 (M series) 
 28 ILLEGAL PLANE SELECT 
 29 ILLEGAL OFFSET VALUE (M series) 
 29 ILLEGAL OFFSET VALUE (T series) 
 30 ILLEGAL OFFSET NUMBER (M series) 
 30 ILLEGAL OFFSET NUMBER (T series) 
 31 ILLEGAL P COMMAND IN G10 
 32 ILLEGAL OFFSET VALUE IN G10 
 33 NO SOLUTION AT CRC (M series) 
 33 NO SOLUTION AT CRC (T series) 
 34 NO CIRC ALLOWED IN ST–UP /EXT BLK (M series) 
 34 NO CIRC ALLOWED IN ST–UP /EXT BLK (T series) 
 35 CAN NOT COMMANDED G39 (M series) 
 35 CAN NOT COMMANDED G31 (T series) 
 36 CAN NOT COMMANDED G31 (M series) 
 37 CAN NOT CHANGE PLANE IN CRC (M seires) 
 37 CAN NOT CHANGE PLANE IN NRC (T seires) 
 38 INTERFERENCE IN CIRCULAR BLOCK (M seires) 
 38 INTERFERENCE IN CIRCULAR BLOCK (T series) 
 39 CHF/CNR NOT ALLOWED IN NRC (T series) 
 40 INTERFERENCE IN G90/G94 BLOCK (T series) 
 41 INTERFERENCE IN CRC (M seires) 
 41 INTERFERENCE IN NRC (T seires) 
 42 G45/G48 NOT ALLOWED IN CRC (M series)
 43 ILLEGAL T–CODE COMMAND (Fanuc 16iLModel A) 
 44 G27–G30 NOT ALLOWED IN FIXED CYC (M series) 
 45 ADDRESS Q NOT FOUND (G73/G83) (M series) 
 46 ILLEGAL REFERENCE RETURN COMMAND 
 47 ILLEGAL AXIS SELECT 
 48 BASIC 3 AXIS NOT FOUND 
 49 ILLEGAL OPERATION (G68/G69) (M series) 
 50 CHF/CNR NOT ALLOWED IN THRD BLK (M series) 
 50 CHF/CNR NOT ALLOWED IN THRD BLK(T series) 
 51 MISSINGMOVE AFTER CHF/CNR (M series) 
 51 MISSINGMOVE AFTER CHF/CNR (T series) 
 52 CODE IS NOT G01 AFTER CHF/CNR (M series) 
 52 CODE IS NOT G01 AFTER CHF/CNR (T series) 
 53 TOO MANY ADDRESS COMMANDS (M series) 
 53 TOO MANY ADDRESS COMMANDS (T seires) 
 54 NO TAPER ALLOWED AFTER CHF/CNR (T series) 
 55 MISSINGMOVE VALUE IN CHF/CNR (M series) 
 55 MISSINGMOVE VALUE IN CHF/CNR (T series) 
 56 NO END POINT & ANGLE IN CHF/CNR (T series) 
 57 NO SOLUTION OF BLOCK END (T series) 
 58 END POINT NOT FOUND (M series) 
 58 END POINT NOT FOUND (T series) 
 59 PROGRAM NUMBER NOT FOUND 
 60 SEQUENCE NUMBER NOT FOUND 
 61 ADDRESS P/Q NOT FOUND IN G70–G73 (T series) 
 62 ILLEGAL COMMAND IN G71–G76 (T series) 
 63 SEQUENCE NUMBER NOT FOUND (T series) 
 64 SHAPE PROGRAMNOT MONOTONOUSLY(T series) 
 65 ILLEGAL COMMAND IN G71–G73 (T series) 
 66 IMPROPER G–CODE IN G71–G73 (T series) 
 67 CAN NOT ERROR IN MDIMODE (T series) 
 69 FORMAT ERROR IN G70– G73 (T series) 
 70 NO PROGRAM SPACE IN MEMORY 
 71 DATA NOT FOUND 
 72 TOO MANY PROGRAMS 
 73 PROGRAM NUMBER ALREADY IN 
 74 ILLEGAL PROGRAMNUMBER 
 75 PROTECT 
 76 ADDRESS P NOT DEFINED 
 77 SUB PROGRAM NESTING ERROR 
 78 NUMBER NOT FOUND 
 79 PROGRAM VERIFY ERROR 
 80 G37 ARRIVAL SIGNAL NOT ASSERTED (M series) 
 80 G37 ARRIVAL SIGNAL NOT ASSERTED (T series) 
 81 OFFSET NUMBER NOT FOUND IN G37 (M series) 
 81 OFFSET NUMBER NOT FOUND IN G37 (T series)
 82 H–CODE NOT ALLOWED IN G37 (M series) 
 82 T–CODE NOT ALLOWED IN G37 (T series) 
 83 ILLEGAL AXIS COMMAND IN G37 (M series) 
 83 ILLEGAL AXIS COMMAND IN G37 (T series) 
 85 COMMUNICATIONERROR 
 86 DR SIGNAL OFF 
 87 BUFFER OVERFLOW 
 88 LAN FILE TRANS ERROR (CHANNEL–1) 
 89 LAN FILE TRANS ERROR (CHANNEL–2) 
 90 REFERENCE RETURN INCOMPLETE 
 91 REFERENCE RETURN INCOMPLETE 
 92 AXES NOT ON THE REFERENCE POINT 
 94 P TYPE NOT ALLOWED (COORD CHG) 
 95 P TYPE NOT ALLOWED (EXT OFS CHG) 
 96 P TYPE NOT ALLOWED (WRK OFS CHG) 
 97 P TYPE NOT ALLOWED (AUTO EXEC) 
 98 G28 FOUND IN SEQUENCE RETURN 
 99 MDI EXEC NOT ALLOWED AFT. SEARCH 
 100 PARAMETERWRITE ENABLE 
 101 PLEASE CLEAR MEMORY 
 109 FORMAT ERROR IN G08 (M series) 
 110 DATA OVERFLOW 
 111 CALCULATED DATA OVERFLOW 
 112 DIVIDED BY ZERO 
 113 IMPROPER COMMAND 
 114 FORMAT ERROR IN MACRO 
 115 ILLEGAL VARIABLE NUMBER 
 116 WRITE PROTECTED VARIABLE 
 118 PARENTHESIS NESTING ERROR 
 119 ILLEGAL ARGUMENT 
 122 FOUR FOLDMACROMODAL– CALL 
 123 CAN NOT USE MACRO COMMAND IN DNC 
 124 MISSING END STATEMENT 
 125 FORMAT ERROR IN MACRO 
 126 ILLEGAL LOOP NUMBER 
 127 NC, MACRO STATEMENT IN SAME BLOCK 
 128 ILLEGALMACRO SEQUENCE NUMBER 
 129 ILLEGAL ARGUMENT ADDRESS 
 130 ILLEGAL AXIS OPERATION 
 131 TOO MANY EXTERNALALARMMESSAGES 
 132 ALARM NUMBER NOT FOUND 
 133 ILLEGAL DATA IN EXT. ALARM MSG 
 135 ILLEGAL ANGLE COMMAND (M series) 
 135 SPINDLE ORIENTATION PLEASE (T series) 
 136 ILLEGAL AXIS COMMAND (M series) 
 136 C/H–CODE & MOVE CMD IN SAME BLK. (T series)
 137 M–CODE & MOVE CMD IN SAME BLK. 
 138 SUPERIMPOSEDDATA OVERFLOW 
 139 CAN NOT CHANGE PMC CONTROL AXIS 
 141 CAN NOT COMMAND G51 IN CRC (M series) 
 142 ILLEGAL SCALE RATE (M series) 
 143 SCALEDMOTION DATA OVERFLOW(M series) 
 144 ILLEGAL PLANE SELECTED (M series) 
 145 ILLEGAL CONDITIONS IN POLAR COORDINATE INTERPOLATION 
 146 IMPROPER G CODE 
 148 ILLEGAL SETTING DATA (M series) 
 149 FORMAT ERROR IN G10L3 (M series) 
 150 ILLEGAL TOOL GROUP NUMBER 
 151 TOOL GROUP NUMBER NOT FOUND 
 152 NO SPACE FOR TOOL ENTRY 
 153 T–CODE NOT FOUND 
 154 NOT USING TOOL IN LIFE GROUP (M series) 
 155 ILLEGAL T–CODE IN M06 (M series) 
 155 ILLEGAL T–CODE IN M06 (T series) 
 156 P/L COMMAND NOT FOUND 
 157 TOO MANY TOOL GROUPS 
 158 ILLEGAL TOOL LIFE DATA 
 159 TOOL DATA SETTING INCOMPLETE 
 160 MISMATCHWAITINGM–CODE (T series (At two–path)) 
 160 G72.1 NESTING ERROR (M series)) 
 161 ILLEGAL P OF WAITINGM–CODE (T series (three–path control) 
 161 G72.1 NESTING ERROR (M series) 
 163 COMMAND G68/G69 INDEPENDENTLY T series (At two–path) 
 169 ILLEGAL TOOL GEOMETRY DATA (At two–path) (Fanuc 16i/18i Model A) 
 175 ILLEGAL G107 COMMAND 
 176 IMPROPER G–CODE IN G107 (M series) 
 176 IMPROPER G–CODE IN G107 (T series) 
 177 CHECK SUM ERROR (G05 MODE) 
 178 G05 COMMANDED IN G41/G42 MODE 
 179 PARAM. (NO. 7510) SETTING ERROR 
 180 COMMUNICATIONERROR (REMOTE BUF) 
 181 FORMAT ERROR IN G81 BLOCK (Hobbingmachine, EGB) (M series) 
 182 G81 NOT COMMANDED (Hobbingmachine) (M series) 
 183 DUPLICATE G83 (COMMANDS) (Hobbingmachine) (M series) 
 184 ILLEGAL COMMAND IN G81 (Hobbingmachine, EGB) (M series) 
 185 RETURN TO REFERENCE POINT (Hobbingmachine) (M series) 
 186 PARAMETER SETTING ERROR (Hobbing machine, EGB) (M series) 
 190 ILLEGAL AXIS SELECT (M series) 
 194 SPINDLE COMMAND IN SYNCHRO–MODE 
 195 MODE CHANGE ERROR (Fanuc 16iLModel A) 
 197 C–AXIS COMMANDED IN SPINDLE MODE 
 199 MACROWORD UNDEFINED
 200 ILLEGAL S CODE COMMAND 
 201 FEEDRATE NOT FOUND IN RIGID TAP 
 202 POSITION LSI OVERFLOW 
 203 PROGRAMMISS AT RIGID TAPPING 
 204 ILLEGAL AXIS OPERATION 
 205 RIGID MODE DI SIGNAL OFF 
 206 CAN NOT CHANGE PLANE (RIGID TAP) (M series) 
 207 RIGID DATA MISMATCH 
 210 CAN NOT COMANDM198/M199 
 211 G31 (HIGH) NOT ALLOWED IN G99 
 212 ILLEGAL PLANE SELECT (M series) 
 212 ILLEGAL PLANE SELECT (T series) 
 213 ILLEGAL COMMAND IN SYNCHRO–MODE 
 213 ILLEGAL COMMAND IN SYNCHRO–MODE (T series) 
 214 ILLEGAL COMMAND IN SYNCHRO–MODE 
 217 DUPLICATE G51.2 (COMMANDS) (T series) 
 218 NOT FOUND P/Q COMMAND IN G251 (T series) 
 219 COMMAND G250/G251 INDEPENDENTLY(T series) 
 220 ILLEGAL COMMAND IN SYNCHR–MODE(T series) 
 221 ILLEGAL COMMAND IN SYNCHR–MODE(T series) 
 222 DNC OP. NOT ALLOWED IN BG.–EDIT (M series) 
 224 RETURN TO REFERENCE POINT (M series) 
 224 RETURN TO REFERENCE POINT (T series) 
 225 SYNCHRONOUS/MIXED CONTROL ERROR (T series (At two–path)) 
 226 ILLEGAL COMMAND IN SYNCHRO– MODE (T series (At two–path)) 
 229 CAN NOT KEEP SYNCHRO–STATE (T series) 
 230 R CODE NOT FOUND (Grindingmachine) (M series) 
 231 ILLEGAL FORMAT IN G10 OR L50 
 232 TOO MANY HELICALAXIS COMMANDS 
 233 DEVICE BUSY 
 239 BP/S ALARM 
 240 BP/S ALARM 
 241 ILLEGAL FORMAT IN G02.2/G03.2 (M series) 
 242 ILLEGAL COMMAND IN G02.2/G03.2 (M series) 
 243 OVER TOLERANCE OF END POINT (M series) 
 244 P/S ALARM(T series) 
 245 T–CODE NOT ALOWEE IN THIS BLOCK (T series) 
 246 ENCODE PROGRAM NUMBER ERROR 
 247 ILLEGAL CODE USED FOR OUTPUT 
 250 Z AXIS WRONG COMMAND (ATC) (M series) 
 251 ATC ERROR (M series) 
 252 ATC SPINDLE ALARM (M series) 
 253 G05 IS NOT AVAILABLE (M series) 
 4000 P/S ALARM (Fanuc 16iLModel A) 
 4001 P/S ALARM (Fanuc 16iLModel A) 
 4002 UNAVAILABLE G–CODE IN SEARCH (Fanuc 16iLModel A)
 4004 3–D COORD. CONV. ALARM (Fanuc 16iLModel A) 
 4005 3–D COORD. CONV. ALARM (Fanuc 16iLModel A) 
 4006 3–D COORD. CONV. ALARM (Fanuc 16iLModel A) 
 4007 3–D COORD. CONV. ALARM (Fanuc 16iLModel A) 
 4008 3–D COORD. CONV. ALARM (Fanuc 16iLModel A) 
 4010 3–D TRANSFORMFORMAT ERROR (Fanuc 16iLModel A) 
 4011 CANNOTMAKE MATRIX (Fanuc 16iLModel A) 
 4012 CANNOT CONVERT (Fanuc 16iLModel A) 
 4016 P/S ALARM (Fanuc 16iLModel A) 
 4017 P/S ALARM (Fanuc 16iLModel A) 
 4021 P/S ALARM (Fanuc 16iLModel A) 
 4500 REPOSITIONING INHIBITED 
 4502 ILLEGAL COMMAND IN BOLT HOLE 
 4503 ILLEGAL COMMAND IN LINE AT ANGLE 
 4504 ILLEGAL COMMAND IN ARC 
 4505 ILLEGAL COMMAND IN GRID 
 4506 ILLEGAL COMMAND IN SHARE PROOFS 
 4507 ILLEGAL COMMAND IN SQUARE 
 4508 ILLEGAL COMMAND IN RADIUS 
 4509 ILLEGAL COMMAND IN CUT AT ANGLE 
 4510 ILLEGAL COMMAND IN LINE-PUNCH 
 4511 ILLEGAL COMMAND IN CIRCLE-PUNCH 
 4520 T, M INHIBITED IN NIBBLING-MODE 
 4521 EXCESS NIBBLINGMOVEMENT (X, Y) 
 4522 EXCESS NIBBLINGMOVEMENT (C) 
 4523 ILLEGAL COMMAND IN CIRCLE-NIBBL 
 4524 ILLEGAL COMMAND IN LINE-NIBBL 
 4530 A/BMACRO NUMBER ERROR 
 4531 U/V MACRO FORMAT ERROR 
 4532 IMPROPER U/V MACRO NUMBER 
 4533 U/V MACROMEMORY OVERFLOW 
 4534W MACRO NUMBER NOT FOUND 
 4535 U/V MACRO NESTING ERROR 
 4536 NO W, Q COMMAND IN MULTI-PIECE 
 4537 ILLEGAL Q VALUE IN MULTI-PIECE 
 4538W NO. NOT FOUND IN MULTI-PIECE 
 4539 MULTI-PIECE SETTING IS ZERO 
 4540 MULTI-PIECE COMMANDWITHIN MACRO 
 4542 MULTI-PIECE COMMAND ERROR 
 4543 MULTI-PIECE Q COMMAND ERROR 
 4544 MULTI-PIECE RESTART ERROR 
 4549 ILLEGAL TOOL DATA FORMAT 
 4600 T, C COMMAND IN INTERPOLATION 
 4601 INHIBITED T, M COMMAND 
 4602 ILLEGAL T-CODE 
 4603 C AXIS SYNCHRONOUS ERROR
 4604 ILLEGAL AXIS OPERATION 
 4605 NEED ZRN 
 4606 A T COMMANDWAS ISSUED (Fanuc 16iP Model A/B – 18iP Model B) 
 4630 ILLEGAL COMMAND IN LASER MODE 
 4631 ILLEGAL COMMAND IN PUNCHMODE (Fanuc 16i/18i Model A) 
 4650 IMPROPER G-CODE IN OFFSETMODE 
 4700 PROGRAM ERROR (OT +) 
 4701 PROGRAM ERROR (OT –) 
 4702 PROGRAM ERROR (OT +) 
 4703 PROGRAM ERROR (OT –) 
 4704 PROGRAM ERROR (OT +) 
 4705 PROGRAM ERROR (OT –) 
 5000 ILLEGAL COMMAND CODE (M series) 
 5003 ILLEGAL PARAMETER (HPCC) (M series) 
 5004 HPCC NOT READY 
 5006 TOO MANYWORD IN ONE BLOCK (M series) 
 5007 TOO LARGE DISTANCE (M series) 
 5009 PARAMETER ZERO (DRY RUN) (M series) 
 5010 END OF RECORD 
 5011 PARAMETER ZERO(CUTMAX) (M series) (Fanuc 16i/18i Model A) 
 5012 G05 P10000 ILLEGAL START UP (HPCC) (M series) 
 5013 HPCC: CRC OFS REMAIN AT CANCEL (M series) 
 5014 TRACE DATA NOT FOUND (M series) 
 5015 NO ROTATION AXIS (M series) (M series) 
 5016 ILLEGAL COMBINATIONOFM CODE 
 5018 POLYGON SPINDLE SPEED ERROR (T series) 
 5020 PARAMETER OF RESTART ERROR 
 5030 ILLEGAL COMMAND (G100) (T series) 
 5031 ILLEGAL COMMAND (G100, G102, G103) (T series) 
 5032 NEW PRG REGISTERED IN B– AXS MOVE (T series) 
 5033 NO PROG SPACE IN MEMORY B– AXS (T series) 
 5034 PLURAL COMMAND IN G110 (T series) 
 5035 NO FEEDRATE COMMANDED B–AXS (T series) 
 5036 ADDRESS R NOT DEFINED IN G81–G86 (T series) 
 5037 ADDRESS Q NOT DEFINED IN G83 (T series) 
 5038 TOO MANY STARTM–CODE COMMAND (T series) 
 5039 START UNREGISTERED B–AXS PROG (T series) 
 5040 CAN NOT COMMANDED B–AXS MOVE (T series) 
 5041 CAN NOT COMMANDED G110 BLOCK (T series) 
 5043 TOO MANY G68 NESTING (M series) 
 5044 G68 FORMAT ERROR (M series) 
 5044 G68 FORMAT ERROR (T series) 
 5046 ILLEGAL PARAMETER (ST.COMP) 
 5050 ILL–COMMAND IN CHOPPINGMODE (M series) 
 5051 M–NET CODE ERROR 
 5052 M–NET ETX ERROR
 5053 M–NET CONNECT ERROR 
 5054 M–NET RECEIVE ERROR 
 5055 M–NET PRT/FRT ERROR 
 5057 M–NET BOARD SYSTEM DOWN 
 5058 G35/G36 FORMAT ERROR (T series) 
 5059 RADIUS IS OUT OF RANGE 
 5060 ILLEGAL PARAMETER IN G02.3/G03.3 (M series) 
 5061 ILLEGAL FORMAT IN G02.3/G03.3 (M series) 
 5062 ILLEGAL COMMAND IN G02.3/G03.3 
 5063 IS NOT PRESET AFTER REF. (M series) 
 5064 DIFFERRENT AXIS UNIT (IS– B, IS–C) 
 5065 DIFFERENT AXIS UNIT (PMC AXIS) (M series) 
 5067 (HPCC) (M series) 
 5068 G31 FORMAT ERROR (M series) 
 5069WHL–C:ILLEGAP–DATA (M series) 
 5073 NO DECIMAL POINT 
 5074 ADDRESS DUPLICATIONERROR 
 5082 DATA SERVER ERROR 
 5085 SMOOTH IPL ERROR 1 
 5096 MISMATCHWAITINGM–CODE 
 5110 NOT STOP POSITION 
 5111 IMPROPERMODAL G–CODE (G05.1 G1) (M series) 
 5112 G08 CAN NOT BE COMMANDED(G05.1 G1) (M series) 
 5113 CAN NOT ERROR IN MDIMODE (Fanuc 16i/18i Model A) 
 5114 NOT STOP POSITION (G05.1 Q1) (M series) 
 5115 SPL : ERROR (M series) 
 5116 SPL : ERROR (M series) 
 5117 SPL : ERROR (M series) 
 5118 SPL : ERROR (M series) 
 5122 ILLEGAL COMMAND IN SPIRAL (M series) 
 5123 OVER TOLERANCE OF END POINT (M series) 
 5124 CAN NOT COMMAND SPIRAL (M series) 
 5134 FSSB : OPEN READY TIME OUT 
 5135 FSSB : ERROR MODE 
 5136 FSSB : NUMBER OF AMPS IS SMALL 
 5137 FSSB : CONFIGURATIONERROR 
 5138 FSSB : AXIS SETTING NOT COMPLETE 
 5139 FSSB : ERROR 
 5155 NOT RESTART PROGRAM BY G05 
 5156 ILLEGAL AXIS OPERATION (M series) 
 5157 PARAMETER ZERO (M series) 
 5195 DIRECTION CAN NOT BE JUDGED (T series) 
 5196 ILLEGAL OPERATION (HPCC) (M series) 
 5197 FSSB : OPEN TIME OUT 
 5198 FSSB : ID DATA NOT READ 
 5199 FINE TORQUE SENSING PARAMETER
 5212 SCREEN COPY : PARAMETER ERROR 
 5213 SCREEN COPY : COMMUNICATIONERROR 
 5214 SCREEN COPY : DATA TRANSFER ERROR 
 5218 ILLEGAL PARAMETER (INCL. COMP) 
 5220 REFERENCE POINT ADJUSTMENTMODE 
 5222 SRAM CORRECTABLE ERROR 
 5227 FILE NOT FOUND 
 5228 SAME NAME USED 
 5229WRITE PROTECTED 
 5231 TOO MANY FILES 
 5232 DATA OVER– FLOW 
 5235 COMMUNICATIONERROR 
 5237 READ ERROR 
 5238WRITE ERROR 
 5242 ILLEGAL AXIS NUMBER (M series) 
 5243 DATA OUT OF RANGE (M series) 
 5244 TOO MANY DI ON (M series) 
 5245 OTHER AXIS ARE COMMANDED (M series) 
 5251 ILLEGAL PARAMETER IN G54.2 (M series) 
 5252 ILLEGAL P COMMAND IN G54.2 (M series) 
 5257 G41/G42 NOT ALLOWED IN MDIMODE (M series) 
 5257 G41/G42 NOT ALLOWED IN MDIMODE (T series) 
 5303 TOUCH PANEL ERROR 
 5306 MODE CHANGE ERROR 
 5307 INTERNALDATA OVER FLOW (M series) 
 5400 SPL:ILLEGAL AXIS COMMAND (M series) 
 5401 SPL:ILLEGAL COMMAND (M series) 
 5402 SPL:ILLEGAL AXIS MOVING (M series) 
 5403 SPL:CAN NOT MAKE VECTOR (M series) 
 5405 ILLEGAL PARAMETER IN G41.2/ G42.2 (M series) 
 5406 G41.3/G40 FORMAT ERROR (M series) 
 5407 ILLEGAL COMMAND IN G41.3 (M series) 
 5408 G41.3 ILLEGAL START_UP (M series) 
 5409 ILLEGAL PARAMETER IN G41.3 (M series) 
 5411 NURBS:ILLEGALORDER (M series) 
 5412 NURBS:NO KNOT COMMAND (M series) 
 5413 NURBS:ILLEGALAXIS COMMAND (M series) 
 5414 NURBS:ILLEGALKNOT (M series) 
 5415 NURBS:ILLEGALCANCEL (M series) 
 5416 NURBS:ILLEGALMODE (M series) 
 5417 NURBS:ILLEGALMULTI–KNOT (M series) 
 5418 NURBS:ILLEGALKNOT VALUE (M series) 
 5420 ILLEGAL PARAMETER IN G43.4/ G43.5 (M series) 
 5421 ILLEGAL COMMAND IN G43.4/ G43.5 (M series) 
 5422 EXCESS VELOCITY IN G43.4/ G43.5 (M series) 
 5425 ILLEGAL OFFSET VALUE (M series)
 5430 ILLEGAL COMMAND IN 3–D CIR (M series) 
 5432 G02.4/G03.4 FORMAT ERROR (M series) 
 5433 MANUAL INTERVENTION IN 3–D CIR (M series) 
 5435 PARAMETER OUT OF RANGE (TLAC) (M series) 
 5436 PARAMETER SETTING ERROR 1 (TLAC) (M series) 
 5437 PARAMETER SETTING ERROR 2 (TLAC) (M series) 
 5440 ILLEGAL DRILLING AXIS SELECTED (M series) 
 5445 CRC:MOTION IN G39 (M series) 
 5446 CRC:NO AVOIDANCE (M series) 
 5447 CRC:DANGEROUSAVOIDANCE (M series) 
 5448 CRC:INTERFERENCETO AVD. (M series) 
 5452 IMPROPER G–CODE (5AXIS MODE) (M series) 
 5453 NOTE: G68 IS CANCELED (HPCC) (M series) 
 5455 ILLEGAL ACC. PARAMETER (M series) 
Laser alarms 
Fanuc 16iL Model A 
 4050 CONTOUR DATA ERROR 
 4051 ASSIST GAS DATA ERR. 
 4052 TRACE DATA ERROR 
 4053 PIERCING DATA ERROR 
 4054 E CODE DATA ERROR 
 4055 E CODE NOT COMMANDED 
 4056 OPT. PATH NOT SET 
 4057 G25 DATA ERROR 
 4058 G26 DATA ERROR 
 4060 TRACE ERROR EXCESS 
 4061 A/D CONVERTER–1 
 4062 A/D CONVERTER–2 
 4063 RF POWER SUPPLY 
 4065 SHUTTER ACTION 
 4066 DISCHARGING 
 4067 LASER CABINET OH 
 4068 BEAM REFLECTION 
 4069 LASER IF PCB 
 4070 CHILLER NOT READY 
 4071 ASSIST GAS NOT READY 
 4072 CHILL FLOW 
 4073 LASER GAS PRES. 
 4074 ROOTS BLOWER TEMP. 
 4075 CHILL TEMP. 
 4076 LASER POWER DOWN 
 4077 ABSORBER TEMP. 
 4078 LASER TUBE PRES.
 4079 PUSH RESET KEY 
 4080 LASER TUBE EXHAUST 
 4081 GAS PRES. CONTROL 
 4082 TUBE PRES. SENSOR 
 4083 SHUTTER NOT OPEN 
 4085 MIRROR CLEANING 
 4086 CALL FOR SERVICE 
 4087 SHUTTER OH 
 4088 LASER VOLTAGE DOWN 
 4089 ASSIST GAS NO SELECT 
 4090 LASER NOT GENERATE 
 4091 INVERTER 
 4093 BLOWER GREASE 
 4094 VANE PUMP 
 4095 A/D CONVERTER–3 
 4096 UNDER TRACING 
 4097 TRACE AXIS SELECT 
 4098 TRACE AXIS & PLANE 
 4099 GAS PRES. NOT REACH 
 4100 INVERTER 1 
 4101 OUT OF FREQUENCY 1 
 4102 OUT OF VIBRATION 1 
 4103 T.B NOT STOPPING 1 
 4104 TURBO OVER CURRENT 1 
 4105 TURBO TEMP. 1 
 4106 BLOWER OIL SHORTAGE 
 4107 MIRROR NOT INSTALLED 
 4110 INVERTER 2 
 4111 OUT OF FREQUENCY 2 
 4112 OUT OF VIBRATION 2 
 4113 T. B NOT STOPPING 2 
 4114 TURBO OVER CURRENT 2 
 4115 TURBO TEMP. 2 
 4130 STEP TIME NOT SET 
 4131 INCORRECT STEP DISTANCE SETTING 
 4132 PARAMETERWAS CHANGED 
 4136 INTERNAL PRESSURE TOO HIGH 
 4137 MIXER POWER FAILURE 
 4138 INSUFFICIENT DEGREE OF VACUUM 
 4139 MIXER PRESSURE SWITCH ERROR 
 4140 OSCILLATOR NOT READY 
 4141 INITIAL LOADING 
 4142 DATA RECEIVING ERROR 
 4143 OVER CURRENT ERROR 
 4144 DATA SENDING ERROR 
 4145 TOUCH DISPLAY
 4146 POWER OVER ERROR 
 4148 REG NO. NOT COMMAND 
 4149 SHUTTER OPEN 
Background edit alarm 
BP/S alarm– BP/S alarm occurs in the same number as the P/S alarm that occurs in ordinary 
program edit. (070, 071, 072, 073, 074 085,086,087 etc.) 
 140 BP/S alarm 
Absolute pulse coder (APC) alarms 
 300 n AXIS NEED ZRN 
 301 APC ALARM:n AXIS COMMUNICATION 
 302 APC ALARM:n AXIS OVER TIME 
 303 APC ALARM:n AXIS FRAMING 
 304 APC ALARM:n AXIS PARITY 
 305 APC ALARM:n AXIS PULSEMISS 
 306 APC ALARM:n AXIS BATTERY ZERO 
 307 APC ALARM:n AXIS BATTERY DOWN 1 
 308 APC ALARM:n AXIS BATTERY DOWN 2 
 309 APC ALARM:n AXIS ZRN IMPOSSIBLE 
Serial pulse coder (SPC) alarms 
 360 n AXIS : ABNORMALCHECKSUM (INT) 
 361 n AXIS : ABNORMALPHASE DATA (INT) 
 362 n AXIS : ABNORMALREV.DATA (INT) 
 363 n AXIS : ABNORMALCLOCK (INT) 
 364 n AXIS : SOFT PHASE ALARM (INT) 
 365 n AXIS : BROKEN LED (INT) 
 366 n AXIS : PULSE MISS (INT) 
 367 n AXIS : COUNTMISS (INT) 
 368 n AXIS : SERIAL DATA ERROR (INT) 
 369 n AXIS : DATA TRANS. ERROR (INT) 
 380 n AXIS : BROKEN LED (EXT) 
 381 n AXIS : ABNORMALPHASE (EXT LIN) 
 382 n AXIS : COUNTMISS (EXT) 
 383 n AXIS : PULSE MISS (EXT) 
 384 n AXIS : SOFT PHASE ALARM(EXT) 
 385 n AXIS : SERIAL DATA ERROR (EXT) 
 386 n AXIS : DATA TRANS. ERROR (EXT) 
 387 n AXIS : ABNORMALENCODER (EXT) 
Servo alarms
 400 SERVO ALARM: n–TH AXIS OVERLOAD (Fanuc 16iP Model A/B – 18iP Model 
B) 
 401 SERVO ALARM: n–TH AXIS VRDY OFF 
 402 SERVO ALARM: SV CARD NOT EXIST 
 403 SERVO ALARM: CARD/SOFTMISMATCH 
 404 SERVO ALARM: n–TH AXIS VRDY ON 
 405 SERVO ALARM: (ZERO POINT RETURN FAULT) 
 407 SERVO ALARM: EXCESS ERROR 
 409 SERVO ALARM: n AXIS TORQUE ALM 
 410 SERVO ALARM: n–TH AXIS – EXCESS ERROR 
 411 SERVO ALARM: n–TH AXIS – EXCESS ERROR 
 413 SERVO ALARM: n–th AXIS – LSI OVERFLOW 
 415 SERVO ALARM: n–TH AXIS – EXCESS SHIFT 
 416 SERVO ALARM: n–TH AXIS – DISCONNECTION(Fanuc 16iP Model A/B – 
18iP Model B) 
 417 SERVO ALARM: n–TH AXIS – PARAMETER INCORRECT 
 420 SERVO ALARM: n AXIS SYNC TORQUE (M series) 
 421 SERVO ALARM: n AXIS EXCESS ER (D) 
 422 SERVO ALARM: n AXIS 
 423 SERVO ALARM: n AXIS 
 430 n AXIS : SV. MOTOR OVERHEAT 
 431 n AXIS : CNV. OVERLOAD 
 432 n AXIS : CNV. LOW VOLT CONTROL 
 433 n AXIS : CNV. LOW VOLT DC LINK 
 434 n AXIS : INV. LOW VOLT CONTROL 
 435 n AXIS : INV. LOW VOLT DC LINK 
 436 n AXIS : SOFTTHERMAL (OVC) 
 437 n AXIS : CNV. OVERCURRENT POWER 
 438 n AXIS : INV. ABNORMALCURRENT 
 439 n AXIS : CNV. OVER VOLT DC LINK 
 440 n AXIS : CNV. EX DECELERATIONPOW. 
 441 n AXIS : ABNORMALCURRENT OFFSET 
 442 n AXIS : CNV. CHARGE FAILURE 
 443 n AXIS : CNV. COOLING FAN FAILURE 
 444 n AXIS : INV. COOLING FAN FAILURE 
 445 n AXIS : SOFT DISCONNECT ALARM 
 446 n AXIS : HARD DISCONNECT ALARM 
 447 n AXIS : HARD DISCONNECT (EXT) 
 448 n AXIS : UNMATCHED FEEDBACK ALARM 
 449 n AXIS : INV. IPM ALARM 
 453 n AXIS : SPC SOFT DISCONNECT ALARM 
 460 n AXIS : FSSB DISCONNECT 
 461 n AXIS : ILLEGALAMP INTERFACE 
 462 n AXIS : SEND CNC DATA FAILED 
 463 n AXIS : SEND SLAVE DATA FAILED 
 464 n AXIS : WRITE ID DATA FAILED
 465 n AXIS : READ ID DATA FAILED 
 466 n AXIS : MOTOR/AMP COMBINATION 
 467 n AXIS : ILLEGAL SETTING OF AXIS 
Over travel alarms 
 500 OVER TRAVEL : +n 
 501 OVER TRAVEL : –n 
 502 OVER TRAVEL : +n 
 503 OVER TRAVEL : –n 
 504 OVER TRAVEL : +n 
 505 OVER TRAVEL : –n 
 506 OVER TRAVEL : +n 
 507 OVER TRAVEL : –n 
 508 INTERFERENCE: +n (T series (two–path control)) 
 509 INTERFERENCE: – n (T series (two–path control)) 
 510 OVER TRAVEL: +n 
 511 OVER TRAVEL: –n 
Overheat alarms 
 700 OVERHEAT: CONTROLUNIT 
 701 OVERHEAT: FAN MOTOR 
 704 OVERHEAT: SPINDLE 
Rigid tapping alarms 
 740 RIGID TAP ALARM: EXCESS ERROR 
 741 RIGID TAP ALARM: EXCESS ERROR 
 742 RIGID TAP ALARM: LSI OVER FLOW 
Serial Spindle alarms 
 749 S–SPINDLE LSI ERROR 
 750 SPINDLE SERIAL LINK START FAULT 
 752 FIRST SPINDLEMODE CHANGE FAULT 
 754 SPINDLE–1 ABNORMALTORQUE ALM 
 762 SECOND SPINDLEMODE CHANGE FAULT 
 764 SPINDLE–2 ABNORMALTORQUE ALM 
 772 SPINDLE–3MODE CHANGE ERROR 
 774 SPINDLE–3 ABNORMALTORQUE ALM 
 782 SPINDLE–4MODE CHANGE ERROR 
 784 SPINDLE–4 ABNORMALTORQUE ALM 
Safety zone alarms
 4800 ZONE : PUNCHING INHIBITED 1 
 4801 ZONE : PUNCHING INHIBITED 2 
 4802 ZONE : PUNCHING INHIBITED 3 
 4803 ZONE : PUNCHING INHIBITED 4 
 4804 ZONE : PUNCHING INHIBITED 5 (Fanuc 16iP/18iP Model B) 
 4805 ZONE : PUNCHING INHIBITED 6 (Fanuc 16iP/18iP Model B) 
 4806 ZONE : PUNCHING INHIBITED 7 (Fanuc 16iP/18iP Model B) 
 4807 ZONE : PUNCHING INHIBITED 8 (Fanuc 16iP/18iP Model B) 
 4810 ZONE : ENTERING INHIBITED 1 +X 
 4811 ZONE : ENTERING INHIBITED 1 –X 
 4812 ZONE : ENTERING INHIBITED 2 +X 
 4813 ZONE : ENTERING INHIBITED 2 –X 
 4814 ZONE : ENTERING INHIBITED 3 +X 
 4815 ZONE : ENTERING INHIBITED 3 –X 
 4816 ZONE : ENTERING INHIBITED 4 +X 
 4817 ZONE : ENTERING INHIBITED 4 –X 
 4818 ZONE : ENTERING INHIBITED 5 +X (Fanuc 16iP/18iP Model B) 
 4819 ZONE : ENTERING INHIBITED 5 (Fanuc 16iP/18iP Model B) 
 4820 ZONE : ENTERING INHIBITED 6 +X (Fanuc 16iP/18iP Model B) 
 4821 ZONE : ENTERING INHIBITED 6 (Fanuc 16iP/18iP Model B) 
 4822 ZONE : ENTERING INHIBITED 7 +X (Fanuc 16iP/18iP Model B) 
 4823 ZONE : ENTERING INHIBITED 7 –X (Fanuc 16iP/18iP Model B) 
 4824 ZONE : ENTERING INHIBITED 8 +X (Fanuc 16iP/18iP Model B) 
 4825 ZONE : ENTERING INHIBITED 8 –X (Fanuc 16iP/18iP Model B) 
 4830 ZONE : ENTERING INHIBITED 1 +Y 
 4831 ZONE : ENTERING INHIBITED 1 –Y 
 4832 ZONE : ENTERING INHIBITED 2 +Y 
 4833 ZONE : ENTERING INHIBITED 2 –Y 
 4834 ZONE : ENTERING INHIBITED 3 +Y 
 4835 ZONE : ENTERING INHIBITED 3 –Y 
 4836 ZONE : ENTERING INHIBITED 4 +Y 
 4837 ZONE : ENTERING INHIBITED 4 –Y 
 4838 ZONE : ENTERING INHIBITED 5 +Y (Fanuc 16iP/18iP Model B) 
 4839 ZONE : ENTERING INHIBITED 5 –Y (Fanuc 16iP/18iP Model B) 
 4840 ZONE : ENTERING INHIBITED 6 +Y (Fanuc 16iP/18iP Model B) 
 4841 ZONE : ENTERING INHIBITED 6 –Y (Fanuc 16iP/18iP Model B) 
 4842 ZONE : ENTERING INHIBITED 7 +Y (Fanuc 16iP/18iP Model B) 
 4843 ZONE : ENTERING INHIBITED 7 –Y (Fanuc 16iP/18iP Model B) 
 4844 ZONE : ENTERING INHIBITED 8 +Y (Fanuc 16iP/18iP Model B) 
 4845 ZONE : ENTERING INHIBITED 8 –Y (Fanuc 16iP/18iP Model B) 
 4870 AUTO SETTING FEED ERROR 
 4871 AUTO SETTING PIECES ERROR 
 4872 AUTO SETTING COMMAND ERROR 
System alarms
 900 ROM PARITY 
 910 SRAM PARITY : (BYTE 0) 
 911 SRAM PARITY : (BYTE 1) 
 912 DRAM PARITY : (BYTE 0) 
 913 DRAM PARITY : (BYTE 1) 
 914 DRAM PARITY : (BYTE 2) 
 915 DRAM PARITY : (BYTE 3) 
 916 DRAM PARITY : (BYTE 4) 
 917 DRAM PARITY : (BYTE 5) 
 918 DRAM PARITY : (BYTE 6) 
 919 DRAM PARITY : (BYTE 7) 
 920 SERVO ALARM(1–4 AXIS) 
 921 SERVO ALARM(5–8 AXIS) 
 922 SERVO ALARM(5/6 AXIS) (Fanuc 16iP Model A) 
 924 SERVOMODULE SETTING ERROR (Fanuc 16iP Model A) 
 926 FSSB ALARM 
 930 CPU INTERRUPUT 
 935 SRAM ECC ERROR 
 950 PMC SYSTEM ALARM 
 951 PMCWATCH DOG ALARM 
 970 NMI OCCURRED IN PMCLSI 
 971 NMI OCCURRED IN SLC 
 972 NMI OCCURRED IN OTHER MODULE 
 973 NON MASK INTERRUPT 
 974 F–BUS ERROR 
 975 BUS ERROR 
 976 L– BUS ERROR

Contenu connexe

En vedette

Fanuc manual fanuc series oi-model c
Fanuc manual fanuc series oi-model cFanuc manual fanuc series oi-model c
Fanuc manual fanuc series oi-model cesexton16
 
Servo guide(中文)
Servo guide(中文)Servo guide(中文)
Servo guide(中文)tzb205
 
Comsol multiphysics 43_preview
Comsol multiphysics 43_previewComsol multiphysics 43_preview
Comsol multiphysics 43_preview棟焜 楊
 
Lista de exercícios de sistemas de coordenadas 1 (2)
Lista de exercícios de sistemas de coordenadas 1 (2)Lista de exercícios de sistemas de coordenadas 1 (2)
Lista de exercícios de sistemas de coordenadas 1 (2)Daniel Natividade
 
Fanuc Ot Cnc Training Manual
Fanuc Ot Cnc Training ManualFanuc Ot Cnc Training Manual
Fanuc Ot Cnc Training Manualout2thow
 

En vedette (10)

Fanuc manual fanuc series oi-model c
Fanuc manual fanuc series oi-model cFanuc manual fanuc series oi-model c
Fanuc manual fanuc series oi-model c
 
Servo guide(中文)
Servo guide(中文)Servo guide(中文)
Servo guide(中文)
 
Comsol multiphysics 43_preview
Comsol multiphysics 43_previewComsol multiphysics 43_preview
Comsol multiphysics 43_preview
 
Lista de exercícios de sistemas de coordenadas 1 (2)
Lista de exercícios de sistemas de coordenadas 1 (2)Lista de exercícios de sistemas de coordenadas 1 (2)
Lista de exercícios de sistemas de coordenadas 1 (2)
 
Complete g code list
Complete g code listComplete g code list
Complete g code list
 
Exercício de CNC
Exercício de CNCExercício de CNC
Exercício de CNC
 
Caderno de exercícios
Caderno de exercíciosCaderno de exercícios
Caderno de exercícios
 
Fanuc Ot Cnc Training Manual
Fanuc Ot Cnc Training ManualFanuc Ot Cnc Training Manual
Fanuc Ot Cnc Training Manual
 
Apostila cnc
Apostila cncApostila cnc
Apostila cnc
 
Fanuc alarms fanuc 6 alarms
Fanuc alarms fanuc 6 alarmsFanuc alarms fanuc 6 alarms
Fanuc alarms fanuc 6 alarms
 

Similaire à Fanuc 16i 18i alarms

Similaire à Fanuc 16i 18i alarms (7)

Fanuc 21 alarm codes complete list
Fanuc 21 alarm codes complete listFanuc 21 alarm codes complete list
Fanuc 21 alarm codes complete list
 
Fanuc 15i alarms
Fanuc 15i alarmsFanuc 15i alarms
Fanuc 15i alarms
 
Cnc lathe
Cnc latheCnc lathe
Cnc lathe
 
7311032-ELE.09-20.lr.pdf
7311032-ELE.09-20.lr.pdf7311032-ELE.09-20.lr.pdf
7311032-ELE.09-20.lr.pdf
 
854 f wiring
854 f wiring854 f wiring
854 f wiring
 
Suzuki Samurai SJ413 Parts Catalogue 3th Edition
Suzuki Samurai SJ413 Parts Catalogue 3th EditionSuzuki Samurai SJ413 Parts Catalogue 3th Edition
Suzuki Samurai SJ413 Parts Catalogue 3th Edition
 
854F wiring.pdf
854F wiring.pdf854F wiring.pdf
854F wiring.pdf
 

Plus de Soekarno Revolusi

Plus de Soekarno Revolusi (17)

What is cnc machine reference point
What is cnc machine reference pointWhat is cnc machine reference point
What is cnc machine reference point
 
Stock sparepart yaskawa
Stock sparepart yaskawaStock sparepart yaskawa
Stock sparepart yaskawa
 
Stock orientation card fanuc
Stock orientation card fanucStock orientation card fanuc
Stock orientation card fanuc
 
Stock part mesin cnc
Stock part mesin cncStock part mesin cnc
Stock part mesin cnc
 
Programming doosan mx series m
Programming doosan mx series mProgramming doosan mx series m
Programming doosan mx series m
 
Mitsubishi cnc manuals
Mitsubishi cnc manualsMitsubishi cnc manuals
Mitsubishi cnc manuals
 
Mitsubishi manuals
Mitsubishi manualsMitsubishi manuals
Mitsubishi manuals
 
Mengecek kondisi ibgt dalam kondisi baik atau rusak
Mengecek kondisi ibgt dalam kondisi baik atau rusakMengecek kondisi ibgt dalam kondisi baik atau rusak
Mengecek kondisi ibgt dalam kondisi baik atau rusak
 
Fanuc g code
Fanuc g codeFanuc g code
Fanuc g code
 
Doosan tt series cnc
Doosan tt series cncDoosan tt series cnc
Doosan tt series cnc
 
Doosan mx series alarm list
Doosan mx series alarm listDoosan mx series alarm list
Doosan mx series alarm list
 
Complete okuma lathe g and m codes
Complete okuma lathe g and m codesComplete okuma lathe g and m codes
Complete okuma lathe g and m codes
 
Cnc programming basics.doc
Cnc programming basics.docCnc programming basics.doc
Cnc programming basics.doc
 
Cnc milling
Cnc millingCnc milling
Cnc milling
 
Cnc lathe machine tool turret
Cnc lathe machine tool turretCnc lathe machine tool turret
Cnc lathe machine tool turret
 
Centroid cnc alarms errors messages
Centroid cnc alarms errors messagesCentroid cnc alarms errors messages
Centroid cnc alarms errors messages
 
Abb
AbbAbb
Abb
 

Dernier

The Codex of Business Writing Software for Real-World Solutions 2.pptx
The Codex of Business Writing Software for Real-World Solutions 2.pptxThe Codex of Business Writing Software for Real-World Solutions 2.pptx
The Codex of Business Writing Software for Real-World Solutions 2.pptxMalak Abu Hammad
 
08448380779 Call Girls In Civil Lines Women Seeking Men
08448380779 Call Girls In Civil Lines Women Seeking Men08448380779 Call Girls In Civil Lines Women Seeking Men
08448380779 Call Girls In Civil Lines Women Seeking MenDelhi Call girls
 
Presentation on how to chat with PDF using ChatGPT code interpreter
Presentation on how to chat with PDF using ChatGPT code interpreterPresentation on how to chat with PDF using ChatGPT code interpreter
Presentation on how to chat with PDF using ChatGPT code interpreternaman860154
 
Data Cloud, More than a CDP by Matt Robison
Data Cloud, More than a CDP by Matt RobisonData Cloud, More than a CDP by Matt Robison
Data Cloud, More than a CDP by Matt RobisonAnna Loughnan Colquhoun
 
Powerful Google developer tools for immediate impact! (2023-24 C)
Powerful Google developer tools for immediate impact! (2023-24 C)Powerful Google developer tools for immediate impact! (2023-24 C)
Powerful Google developer tools for immediate impact! (2023-24 C)wesley chun
 
Handwritten Text Recognition for manuscripts and early printed texts
Handwritten Text Recognition for manuscripts and early printed textsHandwritten Text Recognition for manuscripts and early printed texts
Handwritten Text Recognition for manuscripts and early printed textsMaria Levchenko
 
Apidays Singapore 2024 - Building Digital Trust in a Digital Economy by Veron...
Apidays Singapore 2024 - Building Digital Trust in a Digital Economy by Veron...Apidays Singapore 2024 - Building Digital Trust in a Digital Economy by Veron...
Apidays Singapore 2024 - Building Digital Trust in a Digital Economy by Veron...apidays
 
Finology Group – Insurtech Innovation Award 2024
Finology Group – Insurtech Innovation Award 2024Finology Group – Insurtech Innovation Award 2024
Finology Group – Insurtech Innovation Award 2024The Digital Insurer
 
Automating Google Workspace (GWS) & more with Apps Script
Automating Google Workspace (GWS) & more with Apps ScriptAutomating Google Workspace (GWS) & more with Apps Script
Automating Google Workspace (GWS) & more with Apps Scriptwesley chun
 
Exploring the Future Potential of AI-Enabled Smartphone Processors
Exploring the Future Potential of AI-Enabled Smartphone ProcessorsExploring the Future Potential of AI-Enabled Smartphone Processors
Exploring the Future Potential of AI-Enabled Smartphone Processorsdebabhi2
 
Bajaj Allianz Life Insurance Company - Insurer Innovation Award 2024
Bajaj Allianz Life Insurance Company - Insurer Innovation Award 2024Bajaj Allianz Life Insurance Company - Insurer Innovation Award 2024
Bajaj Allianz Life Insurance Company - Insurer Innovation Award 2024The Digital Insurer
 
Scaling API-first – The story of a global engineering organization
Scaling API-first – The story of a global engineering organizationScaling API-first – The story of a global engineering organization
Scaling API-first – The story of a global engineering organizationRadu Cotescu
 
Axa Assurance Maroc - Insurer Innovation Award 2024
Axa Assurance Maroc - Insurer Innovation Award 2024Axa Assurance Maroc - Insurer Innovation Award 2024
Axa Assurance Maroc - Insurer Innovation Award 2024The Digital Insurer
 
04-2024-HHUG-Sales-and-Marketing-Alignment.pptx
04-2024-HHUG-Sales-and-Marketing-Alignment.pptx04-2024-HHUG-Sales-and-Marketing-Alignment.pptx
04-2024-HHUG-Sales-and-Marketing-Alignment.pptxHampshireHUG
 
Factors to Consider When Choosing Accounts Payable Services Providers.pptx
Factors to Consider When Choosing Accounts Payable Services Providers.pptxFactors to Consider When Choosing Accounts Payable Services Providers.pptx
Factors to Consider When Choosing Accounts Payable Services Providers.pptxKatpro Technologies
 
Workshop - Best of Both Worlds_ Combine KG and Vector search for enhanced R...
Workshop - Best of Both Worlds_ Combine  KG and Vector search for  enhanced R...Workshop - Best of Both Worlds_ Combine  KG and Vector search for  enhanced R...
Workshop - Best of Both Worlds_ Combine KG and Vector search for enhanced R...Neo4j
 
How to convert PDF to text with Nanonets
How to convert PDF to text with NanonetsHow to convert PDF to text with Nanonets
How to convert PDF to text with Nanonetsnaman860154
 
Strategies for Unlocking Knowledge Management in Microsoft 365 in the Copilot...
Strategies for Unlocking Knowledge Management in Microsoft 365 in the Copilot...Strategies for Unlocking Knowledge Management in Microsoft 365 in the Copilot...
Strategies for Unlocking Knowledge Management in Microsoft 365 in the Copilot...Drew Madelung
 
From Event to Action: Accelerate Your Decision Making with Real-Time Automation
From Event to Action: Accelerate Your Decision Making with Real-Time AutomationFrom Event to Action: Accelerate Your Decision Making with Real-Time Automation
From Event to Action: Accelerate Your Decision Making with Real-Time AutomationSafe Software
 
GenCyber Cyber Security Day Presentation
GenCyber Cyber Security Day PresentationGenCyber Cyber Security Day Presentation
GenCyber Cyber Security Day PresentationMichael W. Hawkins
 

Dernier (20)

The Codex of Business Writing Software for Real-World Solutions 2.pptx
The Codex of Business Writing Software for Real-World Solutions 2.pptxThe Codex of Business Writing Software for Real-World Solutions 2.pptx
The Codex of Business Writing Software for Real-World Solutions 2.pptx
 
08448380779 Call Girls In Civil Lines Women Seeking Men
08448380779 Call Girls In Civil Lines Women Seeking Men08448380779 Call Girls In Civil Lines Women Seeking Men
08448380779 Call Girls In Civil Lines Women Seeking Men
 
Presentation on how to chat with PDF using ChatGPT code interpreter
Presentation on how to chat with PDF using ChatGPT code interpreterPresentation on how to chat with PDF using ChatGPT code interpreter
Presentation on how to chat with PDF using ChatGPT code interpreter
 
Data Cloud, More than a CDP by Matt Robison
Data Cloud, More than a CDP by Matt RobisonData Cloud, More than a CDP by Matt Robison
Data Cloud, More than a CDP by Matt Robison
 
Powerful Google developer tools for immediate impact! (2023-24 C)
Powerful Google developer tools for immediate impact! (2023-24 C)Powerful Google developer tools for immediate impact! (2023-24 C)
Powerful Google developer tools for immediate impact! (2023-24 C)
 
Handwritten Text Recognition for manuscripts and early printed texts
Handwritten Text Recognition for manuscripts and early printed textsHandwritten Text Recognition for manuscripts and early printed texts
Handwritten Text Recognition for manuscripts and early printed texts
 
Apidays Singapore 2024 - Building Digital Trust in a Digital Economy by Veron...
Apidays Singapore 2024 - Building Digital Trust in a Digital Economy by Veron...Apidays Singapore 2024 - Building Digital Trust in a Digital Economy by Veron...
Apidays Singapore 2024 - Building Digital Trust in a Digital Economy by Veron...
 
Finology Group – Insurtech Innovation Award 2024
Finology Group – Insurtech Innovation Award 2024Finology Group – Insurtech Innovation Award 2024
Finology Group – Insurtech Innovation Award 2024
 
Automating Google Workspace (GWS) & more with Apps Script
Automating Google Workspace (GWS) & more with Apps ScriptAutomating Google Workspace (GWS) & more with Apps Script
Automating Google Workspace (GWS) & more with Apps Script
 
Exploring the Future Potential of AI-Enabled Smartphone Processors
Exploring the Future Potential of AI-Enabled Smartphone ProcessorsExploring the Future Potential of AI-Enabled Smartphone Processors
Exploring the Future Potential of AI-Enabled Smartphone Processors
 
Bajaj Allianz Life Insurance Company - Insurer Innovation Award 2024
Bajaj Allianz Life Insurance Company - Insurer Innovation Award 2024Bajaj Allianz Life Insurance Company - Insurer Innovation Award 2024
Bajaj Allianz Life Insurance Company - Insurer Innovation Award 2024
 
Scaling API-first – The story of a global engineering organization
Scaling API-first – The story of a global engineering organizationScaling API-first – The story of a global engineering organization
Scaling API-first – The story of a global engineering organization
 
Axa Assurance Maroc - Insurer Innovation Award 2024
Axa Assurance Maroc - Insurer Innovation Award 2024Axa Assurance Maroc - Insurer Innovation Award 2024
Axa Assurance Maroc - Insurer Innovation Award 2024
 
04-2024-HHUG-Sales-and-Marketing-Alignment.pptx
04-2024-HHUG-Sales-and-Marketing-Alignment.pptx04-2024-HHUG-Sales-and-Marketing-Alignment.pptx
04-2024-HHUG-Sales-and-Marketing-Alignment.pptx
 
Factors to Consider When Choosing Accounts Payable Services Providers.pptx
Factors to Consider When Choosing Accounts Payable Services Providers.pptxFactors to Consider When Choosing Accounts Payable Services Providers.pptx
Factors to Consider When Choosing Accounts Payable Services Providers.pptx
 
Workshop - Best of Both Worlds_ Combine KG and Vector search for enhanced R...
Workshop - Best of Both Worlds_ Combine  KG and Vector search for  enhanced R...Workshop - Best of Both Worlds_ Combine  KG and Vector search for  enhanced R...
Workshop - Best of Both Worlds_ Combine KG and Vector search for enhanced R...
 
How to convert PDF to text with Nanonets
How to convert PDF to text with NanonetsHow to convert PDF to text with Nanonets
How to convert PDF to text with Nanonets
 
Strategies for Unlocking Knowledge Management in Microsoft 365 in the Copilot...
Strategies for Unlocking Knowledge Management in Microsoft 365 in the Copilot...Strategies for Unlocking Knowledge Management in Microsoft 365 in the Copilot...
Strategies for Unlocking Knowledge Management in Microsoft 365 in the Copilot...
 
From Event to Action: Accelerate Your Decision Making with Real-Time Automation
From Event to Action: Accelerate Your Decision Making with Real-Time AutomationFrom Event to Action: Accelerate Your Decision Making with Real-Time Automation
From Event to Action: Accelerate Your Decision Making with Real-Time Automation
 
GenCyber Cyber Security Day Presentation
GenCyber Cyber Security Day PresentationGenCyber Cyber Security Day Presentation
GenCyber Cyber Security Day Presentation
 

Fanuc 16i 18i alarms

  • 1. Fanuc 16i 18i Alarms Codes You can Join at Our Group Facebook : CNC INDONESIA or Email :soekarno.gempar@gmail Fanuc 16i 18i Alarms Codes for CNC machinists. These Fanuc alarm code applies to following Fanuc CNC controls  Fanuc 16i/18i Model A  Fanuc 16i/18i Model B  Fanuc 16iLModel A  Fanuc 16iP Model A  Fanuc 16iP/18iP Model B FANUC 18i-MB Contents  Fanuc 16i 18i Alarms o Program errors (P/S alarm) o Laser alarms o Background edit alarm o Absolute pulse coder (APC) alarms o Serial pulse coder (SPC) alarms o Servo alarms o Over travel alarms o Overheat alarms
  • 2. o Rigid tapping alarms o Serial Spindle alarms o Safety zone alarms o System alarms Fanuc 16i 18i Alarms
  • 3. Program errors (P/S alarm)  0 PLEASE TURN OFF POWER  1 TH PARITY ALARM  2 TV PARITY ALARM  3 TOO MANY DIGITS  4 ADDRESS NOT FOUND  5 NO DATA AFTER ADDRESS  6 ILLEGAL USE OF NEGATIVE SIGN  7 ILLEGAL USE OF DECIMAL POINT  9 ILLEGAL ADDRESS INPUT  10 IMPROPER G–CODE  11 NO FEEDRATE COMMANDED  14 CAN NOT COMMAND G95 (M series)  14 ILLEGAL LEAD COMMAND (T series)  15 TOO MANY AXES COMMANDED (M series)  15 TOO MANY AXES COMMANDED (T series)  20 OVER TOLERANCE OF RADIUS  21 ILLEGAL PLANE AXIS COMMANDED  22 NO CIRCLE RADIUS  23 ILLEGAL RADIUS COMMAND (T series)  25 CANNOT COMMAND F0 IN G02/G03 (M series)  27 NO AXES COMMANDED IN G43/G44 (M series)  28 ILLEGAL PLANE SELECT  29 ILLEGAL OFFSET VALUE (M series)  29 ILLEGAL OFFSET VALUE (T series)  30 ILLEGAL OFFSET NUMBER (M series)  30 ILLEGAL OFFSET NUMBER (T series)  31 ILLEGAL P COMMAND IN G10  32 ILLEGAL OFFSET VALUE IN G10  33 NO SOLUTION AT CRC (M series)  33 NO SOLUTION AT CRC (T series)  34 NO CIRC ALLOWED IN ST–UP /EXT BLK (M series)  34 NO CIRC ALLOWED IN ST–UP /EXT BLK (T series)  35 CAN NOT COMMANDED G39 (M series)  35 CAN NOT COMMANDED G31 (T series)  36 CAN NOT COMMANDED G31 (M series)  37 CAN NOT CHANGE PLANE IN CRC (M seires)  37 CAN NOT CHANGE PLANE IN NRC (T seires)  38 INTERFERENCE IN CIRCULAR BLOCK (M seires)  38 INTERFERENCE IN CIRCULAR BLOCK (T series)  39 CHF/CNR NOT ALLOWED IN NRC (T series)  40 INTERFERENCE IN G90/G94 BLOCK (T series)  41 INTERFERENCE IN CRC (M seires)  41 INTERFERENCE IN NRC (T seires)  42 G45/G48 NOT ALLOWED IN CRC (M series)
  • 4.  43 ILLEGAL T–CODE COMMAND (Fanuc 16iLModel A)  44 G27–G30 NOT ALLOWED IN FIXED CYC (M series)  45 ADDRESS Q NOT FOUND (G73/G83) (M series)  46 ILLEGAL REFERENCE RETURN COMMAND  47 ILLEGAL AXIS SELECT  48 BASIC 3 AXIS NOT FOUND  49 ILLEGAL OPERATION (G68/G69) (M series)  50 CHF/CNR NOT ALLOWED IN THRD BLK (M series)  50 CHF/CNR NOT ALLOWED IN THRD BLK(T series)  51 MISSINGMOVE AFTER CHF/CNR (M series)  51 MISSINGMOVE AFTER CHF/CNR (T series)  52 CODE IS NOT G01 AFTER CHF/CNR (M series)  52 CODE IS NOT G01 AFTER CHF/CNR (T series)  53 TOO MANY ADDRESS COMMANDS (M series)  53 TOO MANY ADDRESS COMMANDS (T seires)  54 NO TAPER ALLOWED AFTER CHF/CNR (T series)  55 MISSINGMOVE VALUE IN CHF/CNR (M series)  55 MISSINGMOVE VALUE IN CHF/CNR (T series)  56 NO END POINT & ANGLE IN CHF/CNR (T series)  57 NO SOLUTION OF BLOCK END (T series)  58 END POINT NOT FOUND (M series)  58 END POINT NOT FOUND (T series)  59 PROGRAM NUMBER NOT FOUND  60 SEQUENCE NUMBER NOT FOUND  61 ADDRESS P/Q NOT FOUND IN G70–G73 (T series)  62 ILLEGAL COMMAND IN G71–G76 (T series)  63 SEQUENCE NUMBER NOT FOUND (T series)  64 SHAPE PROGRAMNOT MONOTONOUSLY(T series)  65 ILLEGAL COMMAND IN G71–G73 (T series)  66 IMPROPER G–CODE IN G71–G73 (T series)  67 CAN NOT ERROR IN MDIMODE (T series)  69 FORMAT ERROR IN G70– G73 (T series)  70 NO PROGRAM SPACE IN MEMORY  71 DATA NOT FOUND  72 TOO MANY PROGRAMS  73 PROGRAM NUMBER ALREADY IN  74 ILLEGAL PROGRAMNUMBER  75 PROTECT  76 ADDRESS P NOT DEFINED  77 SUB PROGRAM NESTING ERROR  78 NUMBER NOT FOUND  79 PROGRAM VERIFY ERROR  80 G37 ARRIVAL SIGNAL NOT ASSERTED (M series)  80 G37 ARRIVAL SIGNAL NOT ASSERTED (T series)  81 OFFSET NUMBER NOT FOUND IN G37 (M series)  81 OFFSET NUMBER NOT FOUND IN G37 (T series)
  • 5.  82 H–CODE NOT ALLOWED IN G37 (M series)  82 T–CODE NOT ALLOWED IN G37 (T series)  83 ILLEGAL AXIS COMMAND IN G37 (M series)  83 ILLEGAL AXIS COMMAND IN G37 (T series)  85 COMMUNICATIONERROR  86 DR SIGNAL OFF  87 BUFFER OVERFLOW  88 LAN FILE TRANS ERROR (CHANNEL–1)  89 LAN FILE TRANS ERROR (CHANNEL–2)  90 REFERENCE RETURN INCOMPLETE  91 REFERENCE RETURN INCOMPLETE  92 AXES NOT ON THE REFERENCE POINT  94 P TYPE NOT ALLOWED (COORD CHG)  95 P TYPE NOT ALLOWED (EXT OFS CHG)  96 P TYPE NOT ALLOWED (WRK OFS CHG)  97 P TYPE NOT ALLOWED (AUTO EXEC)  98 G28 FOUND IN SEQUENCE RETURN  99 MDI EXEC NOT ALLOWED AFT. SEARCH  100 PARAMETERWRITE ENABLE  101 PLEASE CLEAR MEMORY  109 FORMAT ERROR IN G08 (M series)  110 DATA OVERFLOW  111 CALCULATED DATA OVERFLOW  112 DIVIDED BY ZERO  113 IMPROPER COMMAND  114 FORMAT ERROR IN MACRO  115 ILLEGAL VARIABLE NUMBER  116 WRITE PROTECTED VARIABLE  118 PARENTHESIS NESTING ERROR  119 ILLEGAL ARGUMENT  122 FOUR FOLDMACROMODAL– CALL  123 CAN NOT USE MACRO COMMAND IN DNC  124 MISSING END STATEMENT  125 FORMAT ERROR IN MACRO  126 ILLEGAL LOOP NUMBER  127 NC, MACRO STATEMENT IN SAME BLOCK  128 ILLEGALMACRO SEQUENCE NUMBER  129 ILLEGAL ARGUMENT ADDRESS  130 ILLEGAL AXIS OPERATION  131 TOO MANY EXTERNALALARMMESSAGES  132 ALARM NUMBER NOT FOUND  133 ILLEGAL DATA IN EXT. ALARM MSG  135 ILLEGAL ANGLE COMMAND (M series)  135 SPINDLE ORIENTATION PLEASE (T series)  136 ILLEGAL AXIS COMMAND (M series)  136 C/H–CODE & MOVE CMD IN SAME BLK. (T series)
  • 6.  137 M–CODE & MOVE CMD IN SAME BLK.  138 SUPERIMPOSEDDATA OVERFLOW  139 CAN NOT CHANGE PMC CONTROL AXIS  141 CAN NOT COMMAND G51 IN CRC (M series)  142 ILLEGAL SCALE RATE (M series)  143 SCALEDMOTION DATA OVERFLOW(M series)  144 ILLEGAL PLANE SELECTED (M series)  145 ILLEGAL CONDITIONS IN POLAR COORDINATE INTERPOLATION  146 IMPROPER G CODE  148 ILLEGAL SETTING DATA (M series)  149 FORMAT ERROR IN G10L3 (M series)  150 ILLEGAL TOOL GROUP NUMBER  151 TOOL GROUP NUMBER NOT FOUND  152 NO SPACE FOR TOOL ENTRY  153 T–CODE NOT FOUND  154 NOT USING TOOL IN LIFE GROUP (M series)  155 ILLEGAL T–CODE IN M06 (M series)  155 ILLEGAL T–CODE IN M06 (T series)  156 P/L COMMAND NOT FOUND  157 TOO MANY TOOL GROUPS  158 ILLEGAL TOOL LIFE DATA  159 TOOL DATA SETTING INCOMPLETE  160 MISMATCHWAITINGM–CODE (T series (At two–path))  160 G72.1 NESTING ERROR (M series))  161 ILLEGAL P OF WAITINGM–CODE (T series (three–path control)  161 G72.1 NESTING ERROR (M series)  163 COMMAND G68/G69 INDEPENDENTLY T series (At two–path)  169 ILLEGAL TOOL GEOMETRY DATA (At two–path) (Fanuc 16i/18i Model A)  175 ILLEGAL G107 COMMAND  176 IMPROPER G–CODE IN G107 (M series)  176 IMPROPER G–CODE IN G107 (T series)  177 CHECK SUM ERROR (G05 MODE)  178 G05 COMMANDED IN G41/G42 MODE  179 PARAM. (NO. 7510) SETTING ERROR  180 COMMUNICATIONERROR (REMOTE BUF)  181 FORMAT ERROR IN G81 BLOCK (Hobbingmachine, EGB) (M series)  182 G81 NOT COMMANDED (Hobbingmachine) (M series)  183 DUPLICATE G83 (COMMANDS) (Hobbingmachine) (M series)  184 ILLEGAL COMMAND IN G81 (Hobbingmachine, EGB) (M series)  185 RETURN TO REFERENCE POINT (Hobbingmachine) (M series)  186 PARAMETER SETTING ERROR (Hobbing machine, EGB) (M series)  190 ILLEGAL AXIS SELECT (M series)  194 SPINDLE COMMAND IN SYNCHRO–MODE  195 MODE CHANGE ERROR (Fanuc 16iLModel A)  197 C–AXIS COMMANDED IN SPINDLE MODE  199 MACROWORD UNDEFINED
  • 7.  200 ILLEGAL S CODE COMMAND  201 FEEDRATE NOT FOUND IN RIGID TAP  202 POSITION LSI OVERFLOW  203 PROGRAMMISS AT RIGID TAPPING  204 ILLEGAL AXIS OPERATION  205 RIGID MODE DI SIGNAL OFF  206 CAN NOT CHANGE PLANE (RIGID TAP) (M series)  207 RIGID DATA MISMATCH  210 CAN NOT COMANDM198/M199  211 G31 (HIGH) NOT ALLOWED IN G99  212 ILLEGAL PLANE SELECT (M series)  212 ILLEGAL PLANE SELECT (T series)  213 ILLEGAL COMMAND IN SYNCHRO–MODE  213 ILLEGAL COMMAND IN SYNCHRO–MODE (T series)  214 ILLEGAL COMMAND IN SYNCHRO–MODE  217 DUPLICATE G51.2 (COMMANDS) (T series)  218 NOT FOUND P/Q COMMAND IN G251 (T series)  219 COMMAND G250/G251 INDEPENDENTLY(T series)  220 ILLEGAL COMMAND IN SYNCHR–MODE(T series)  221 ILLEGAL COMMAND IN SYNCHR–MODE(T series)  222 DNC OP. NOT ALLOWED IN BG.–EDIT (M series)  224 RETURN TO REFERENCE POINT (M series)  224 RETURN TO REFERENCE POINT (T series)  225 SYNCHRONOUS/MIXED CONTROL ERROR (T series (At two–path))  226 ILLEGAL COMMAND IN SYNCHRO– MODE (T series (At two–path))  229 CAN NOT KEEP SYNCHRO–STATE (T series)  230 R CODE NOT FOUND (Grindingmachine) (M series)  231 ILLEGAL FORMAT IN G10 OR L50  232 TOO MANY HELICALAXIS COMMANDS  233 DEVICE BUSY  239 BP/S ALARM  240 BP/S ALARM  241 ILLEGAL FORMAT IN G02.2/G03.2 (M series)  242 ILLEGAL COMMAND IN G02.2/G03.2 (M series)  243 OVER TOLERANCE OF END POINT (M series)  244 P/S ALARM(T series)  245 T–CODE NOT ALOWEE IN THIS BLOCK (T series)  246 ENCODE PROGRAM NUMBER ERROR  247 ILLEGAL CODE USED FOR OUTPUT  250 Z AXIS WRONG COMMAND (ATC) (M series)  251 ATC ERROR (M series)  252 ATC SPINDLE ALARM (M series)  253 G05 IS NOT AVAILABLE (M series)  4000 P/S ALARM (Fanuc 16iLModel A)  4001 P/S ALARM (Fanuc 16iLModel A)  4002 UNAVAILABLE G–CODE IN SEARCH (Fanuc 16iLModel A)
  • 8.  4004 3–D COORD. CONV. ALARM (Fanuc 16iLModel A)  4005 3–D COORD. CONV. ALARM (Fanuc 16iLModel A)  4006 3–D COORD. CONV. ALARM (Fanuc 16iLModel A)  4007 3–D COORD. CONV. ALARM (Fanuc 16iLModel A)  4008 3–D COORD. CONV. ALARM (Fanuc 16iLModel A)  4010 3–D TRANSFORMFORMAT ERROR (Fanuc 16iLModel A)  4011 CANNOTMAKE MATRIX (Fanuc 16iLModel A)  4012 CANNOT CONVERT (Fanuc 16iLModel A)  4016 P/S ALARM (Fanuc 16iLModel A)  4017 P/S ALARM (Fanuc 16iLModel A)  4021 P/S ALARM (Fanuc 16iLModel A)  4500 REPOSITIONING INHIBITED  4502 ILLEGAL COMMAND IN BOLT HOLE  4503 ILLEGAL COMMAND IN LINE AT ANGLE  4504 ILLEGAL COMMAND IN ARC  4505 ILLEGAL COMMAND IN GRID  4506 ILLEGAL COMMAND IN SHARE PROOFS  4507 ILLEGAL COMMAND IN SQUARE  4508 ILLEGAL COMMAND IN RADIUS  4509 ILLEGAL COMMAND IN CUT AT ANGLE  4510 ILLEGAL COMMAND IN LINE-PUNCH  4511 ILLEGAL COMMAND IN CIRCLE-PUNCH  4520 T, M INHIBITED IN NIBBLING-MODE  4521 EXCESS NIBBLINGMOVEMENT (X, Y)  4522 EXCESS NIBBLINGMOVEMENT (C)  4523 ILLEGAL COMMAND IN CIRCLE-NIBBL  4524 ILLEGAL COMMAND IN LINE-NIBBL  4530 A/BMACRO NUMBER ERROR  4531 U/V MACRO FORMAT ERROR  4532 IMPROPER U/V MACRO NUMBER  4533 U/V MACROMEMORY OVERFLOW  4534W MACRO NUMBER NOT FOUND  4535 U/V MACRO NESTING ERROR  4536 NO W, Q COMMAND IN MULTI-PIECE  4537 ILLEGAL Q VALUE IN MULTI-PIECE  4538W NO. NOT FOUND IN MULTI-PIECE  4539 MULTI-PIECE SETTING IS ZERO  4540 MULTI-PIECE COMMANDWITHIN MACRO  4542 MULTI-PIECE COMMAND ERROR  4543 MULTI-PIECE Q COMMAND ERROR  4544 MULTI-PIECE RESTART ERROR  4549 ILLEGAL TOOL DATA FORMAT  4600 T, C COMMAND IN INTERPOLATION  4601 INHIBITED T, M COMMAND  4602 ILLEGAL T-CODE  4603 C AXIS SYNCHRONOUS ERROR
  • 9.  4604 ILLEGAL AXIS OPERATION  4605 NEED ZRN  4606 A T COMMANDWAS ISSUED (Fanuc 16iP Model A/B – 18iP Model B)  4630 ILLEGAL COMMAND IN LASER MODE  4631 ILLEGAL COMMAND IN PUNCHMODE (Fanuc 16i/18i Model A)  4650 IMPROPER G-CODE IN OFFSETMODE  4700 PROGRAM ERROR (OT +)  4701 PROGRAM ERROR (OT –)  4702 PROGRAM ERROR (OT +)  4703 PROGRAM ERROR (OT –)  4704 PROGRAM ERROR (OT +)  4705 PROGRAM ERROR (OT –)  5000 ILLEGAL COMMAND CODE (M series)  5003 ILLEGAL PARAMETER (HPCC) (M series)  5004 HPCC NOT READY  5006 TOO MANYWORD IN ONE BLOCK (M series)  5007 TOO LARGE DISTANCE (M series)  5009 PARAMETER ZERO (DRY RUN) (M series)  5010 END OF RECORD  5011 PARAMETER ZERO(CUTMAX) (M series) (Fanuc 16i/18i Model A)  5012 G05 P10000 ILLEGAL START UP (HPCC) (M series)  5013 HPCC: CRC OFS REMAIN AT CANCEL (M series)  5014 TRACE DATA NOT FOUND (M series)  5015 NO ROTATION AXIS (M series) (M series)  5016 ILLEGAL COMBINATIONOFM CODE  5018 POLYGON SPINDLE SPEED ERROR (T series)  5020 PARAMETER OF RESTART ERROR  5030 ILLEGAL COMMAND (G100) (T series)  5031 ILLEGAL COMMAND (G100, G102, G103) (T series)  5032 NEW PRG REGISTERED IN B– AXS MOVE (T series)  5033 NO PROG SPACE IN MEMORY B– AXS (T series)  5034 PLURAL COMMAND IN G110 (T series)  5035 NO FEEDRATE COMMANDED B–AXS (T series)  5036 ADDRESS R NOT DEFINED IN G81–G86 (T series)  5037 ADDRESS Q NOT DEFINED IN G83 (T series)  5038 TOO MANY STARTM–CODE COMMAND (T series)  5039 START UNREGISTERED B–AXS PROG (T series)  5040 CAN NOT COMMANDED B–AXS MOVE (T series)  5041 CAN NOT COMMANDED G110 BLOCK (T series)  5043 TOO MANY G68 NESTING (M series)  5044 G68 FORMAT ERROR (M series)  5044 G68 FORMAT ERROR (T series)  5046 ILLEGAL PARAMETER (ST.COMP)  5050 ILL–COMMAND IN CHOPPINGMODE (M series)  5051 M–NET CODE ERROR  5052 M–NET ETX ERROR
  • 10.  5053 M–NET CONNECT ERROR  5054 M–NET RECEIVE ERROR  5055 M–NET PRT/FRT ERROR  5057 M–NET BOARD SYSTEM DOWN  5058 G35/G36 FORMAT ERROR (T series)  5059 RADIUS IS OUT OF RANGE  5060 ILLEGAL PARAMETER IN G02.3/G03.3 (M series)  5061 ILLEGAL FORMAT IN G02.3/G03.3 (M series)  5062 ILLEGAL COMMAND IN G02.3/G03.3  5063 IS NOT PRESET AFTER REF. (M series)  5064 DIFFERRENT AXIS UNIT (IS– B, IS–C)  5065 DIFFERENT AXIS UNIT (PMC AXIS) (M series)  5067 (HPCC) (M series)  5068 G31 FORMAT ERROR (M series)  5069WHL–C:ILLEGAP–DATA (M series)  5073 NO DECIMAL POINT  5074 ADDRESS DUPLICATIONERROR  5082 DATA SERVER ERROR  5085 SMOOTH IPL ERROR 1  5096 MISMATCHWAITINGM–CODE  5110 NOT STOP POSITION  5111 IMPROPERMODAL G–CODE (G05.1 G1) (M series)  5112 G08 CAN NOT BE COMMANDED(G05.1 G1) (M series)  5113 CAN NOT ERROR IN MDIMODE (Fanuc 16i/18i Model A)  5114 NOT STOP POSITION (G05.1 Q1) (M series)  5115 SPL : ERROR (M series)  5116 SPL : ERROR (M series)  5117 SPL : ERROR (M series)  5118 SPL : ERROR (M series)  5122 ILLEGAL COMMAND IN SPIRAL (M series)  5123 OVER TOLERANCE OF END POINT (M series)  5124 CAN NOT COMMAND SPIRAL (M series)  5134 FSSB : OPEN READY TIME OUT  5135 FSSB : ERROR MODE  5136 FSSB : NUMBER OF AMPS IS SMALL  5137 FSSB : CONFIGURATIONERROR  5138 FSSB : AXIS SETTING NOT COMPLETE  5139 FSSB : ERROR  5155 NOT RESTART PROGRAM BY G05  5156 ILLEGAL AXIS OPERATION (M series)  5157 PARAMETER ZERO (M series)  5195 DIRECTION CAN NOT BE JUDGED (T series)  5196 ILLEGAL OPERATION (HPCC) (M series)  5197 FSSB : OPEN TIME OUT  5198 FSSB : ID DATA NOT READ  5199 FINE TORQUE SENSING PARAMETER
  • 11.  5212 SCREEN COPY : PARAMETER ERROR  5213 SCREEN COPY : COMMUNICATIONERROR  5214 SCREEN COPY : DATA TRANSFER ERROR  5218 ILLEGAL PARAMETER (INCL. COMP)  5220 REFERENCE POINT ADJUSTMENTMODE  5222 SRAM CORRECTABLE ERROR  5227 FILE NOT FOUND  5228 SAME NAME USED  5229WRITE PROTECTED  5231 TOO MANY FILES  5232 DATA OVER– FLOW  5235 COMMUNICATIONERROR  5237 READ ERROR  5238WRITE ERROR  5242 ILLEGAL AXIS NUMBER (M series)  5243 DATA OUT OF RANGE (M series)  5244 TOO MANY DI ON (M series)  5245 OTHER AXIS ARE COMMANDED (M series)  5251 ILLEGAL PARAMETER IN G54.2 (M series)  5252 ILLEGAL P COMMAND IN G54.2 (M series)  5257 G41/G42 NOT ALLOWED IN MDIMODE (M series)  5257 G41/G42 NOT ALLOWED IN MDIMODE (T series)  5303 TOUCH PANEL ERROR  5306 MODE CHANGE ERROR  5307 INTERNALDATA OVER FLOW (M series)  5400 SPL:ILLEGAL AXIS COMMAND (M series)  5401 SPL:ILLEGAL COMMAND (M series)  5402 SPL:ILLEGAL AXIS MOVING (M series)  5403 SPL:CAN NOT MAKE VECTOR (M series)  5405 ILLEGAL PARAMETER IN G41.2/ G42.2 (M series)  5406 G41.3/G40 FORMAT ERROR (M series)  5407 ILLEGAL COMMAND IN G41.3 (M series)  5408 G41.3 ILLEGAL START_UP (M series)  5409 ILLEGAL PARAMETER IN G41.3 (M series)  5411 NURBS:ILLEGALORDER (M series)  5412 NURBS:NO KNOT COMMAND (M series)  5413 NURBS:ILLEGALAXIS COMMAND (M series)  5414 NURBS:ILLEGALKNOT (M series)  5415 NURBS:ILLEGALCANCEL (M series)  5416 NURBS:ILLEGALMODE (M series)  5417 NURBS:ILLEGALMULTI–KNOT (M series)  5418 NURBS:ILLEGALKNOT VALUE (M series)  5420 ILLEGAL PARAMETER IN G43.4/ G43.5 (M series)  5421 ILLEGAL COMMAND IN G43.4/ G43.5 (M series)  5422 EXCESS VELOCITY IN G43.4/ G43.5 (M series)  5425 ILLEGAL OFFSET VALUE (M series)
  • 12.  5430 ILLEGAL COMMAND IN 3–D CIR (M series)  5432 G02.4/G03.4 FORMAT ERROR (M series)  5433 MANUAL INTERVENTION IN 3–D CIR (M series)  5435 PARAMETER OUT OF RANGE (TLAC) (M series)  5436 PARAMETER SETTING ERROR 1 (TLAC) (M series)  5437 PARAMETER SETTING ERROR 2 (TLAC) (M series)  5440 ILLEGAL DRILLING AXIS SELECTED (M series)  5445 CRC:MOTION IN G39 (M series)  5446 CRC:NO AVOIDANCE (M series)  5447 CRC:DANGEROUSAVOIDANCE (M series)  5448 CRC:INTERFERENCETO AVD. (M series)  5452 IMPROPER G–CODE (5AXIS MODE) (M series)  5453 NOTE: G68 IS CANCELED (HPCC) (M series)  5455 ILLEGAL ACC. PARAMETER (M series) Laser alarms Fanuc 16iL Model A  4050 CONTOUR DATA ERROR  4051 ASSIST GAS DATA ERR.  4052 TRACE DATA ERROR  4053 PIERCING DATA ERROR  4054 E CODE DATA ERROR  4055 E CODE NOT COMMANDED  4056 OPT. PATH NOT SET  4057 G25 DATA ERROR  4058 G26 DATA ERROR  4060 TRACE ERROR EXCESS  4061 A/D CONVERTER–1  4062 A/D CONVERTER–2  4063 RF POWER SUPPLY  4065 SHUTTER ACTION  4066 DISCHARGING  4067 LASER CABINET OH  4068 BEAM REFLECTION  4069 LASER IF PCB  4070 CHILLER NOT READY  4071 ASSIST GAS NOT READY  4072 CHILL FLOW  4073 LASER GAS PRES.  4074 ROOTS BLOWER TEMP.  4075 CHILL TEMP.  4076 LASER POWER DOWN  4077 ABSORBER TEMP.  4078 LASER TUBE PRES.
  • 13.  4079 PUSH RESET KEY  4080 LASER TUBE EXHAUST  4081 GAS PRES. CONTROL  4082 TUBE PRES. SENSOR  4083 SHUTTER NOT OPEN  4085 MIRROR CLEANING  4086 CALL FOR SERVICE  4087 SHUTTER OH  4088 LASER VOLTAGE DOWN  4089 ASSIST GAS NO SELECT  4090 LASER NOT GENERATE  4091 INVERTER  4093 BLOWER GREASE  4094 VANE PUMP  4095 A/D CONVERTER–3  4096 UNDER TRACING  4097 TRACE AXIS SELECT  4098 TRACE AXIS & PLANE  4099 GAS PRES. NOT REACH  4100 INVERTER 1  4101 OUT OF FREQUENCY 1  4102 OUT OF VIBRATION 1  4103 T.B NOT STOPPING 1  4104 TURBO OVER CURRENT 1  4105 TURBO TEMP. 1  4106 BLOWER OIL SHORTAGE  4107 MIRROR NOT INSTALLED  4110 INVERTER 2  4111 OUT OF FREQUENCY 2  4112 OUT OF VIBRATION 2  4113 T. B NOT STOPPING 2  4114 TURBO OVER CURRENT 2  4115 TURBO TEMP. 2  4130 STEP TIME NOT SET  4131 INCORRECT STEP DISTANCE SETTING  4132 PARAMETERWAS CHANGED  4136 INTERNAL PRESSURE TOO HIGH  4137 MIXER POWER FAILURE  4138 INSUFFICIENT DEGREE OF VACUUM  4139 MIXER PRESSURE SWITCH ERROR  4140 OSCILLATOR NOT READY  4141 INITIAL LOADING  4142 DATA RECEIVING ERROR  4143 OVER CURRENT ERROR  4144 DATA SENDING ERROR  4145 TOUCH DISPLAY
  • 14.  4146 POWER OVER ERROR  4148 REG NO. NOT COMMAND  4149 SHUTTER OPEN Background edit alarm BP/S alarm– BP/S alarm occurs in the same number as the P/S alarm that occurs in ordinary program edit. (070, 071, 072, 073, 074 085,086,087 etc.)  140 BP/S alarm Absolute pulse coder (APC) alarms  300 n AXIS NEED ZRN  301 APC ALARM:n AXIS COMMUNICATION  302 APC ALARM:n AXIS OVER TIME  303 APC ALARM:n AXIS FRAMING  304 APC ALARM:n AXIS PARITY  305 APC ALARM:n AXIS PULSEMISS  306 APC ALARM:n AXIS BATTERY ZERO  307 APC ALARM:n AXIS BATTERY DOWN 1  308 APC ALARM:n AXIS BATTERY DOWN 2  309 APC ALARM:n AXIS ZRN IMPOSSIBLE Serial pulse coder (SPC) alarms  360 n AXIS : ABNORMALCHECKSUM (INT)  361 n AXIS : ABNORMALPHASE DATA (INT)  362 n AXIS : ABNORMALREV.DATA (INT)  363 n AXIS : ABNORMALCLOCK (INT)  364 n AXIS : SOFT PHASE ALARM (INT)  365 n AXIS : BROKEN LED (INT)  366 n AXIS : PULSE MISS (INT)  367 n AXIS : COUNTMISS (INT)  368 n AXIS : SERIAL DATA ERROR (INT)  369 n AXIS : DATA TRANS. ERROR (INT)  380 n AXIS : BROKEN LED (EXT)  381 n AXIS : ABNORMALPHASE (EXT LIN)  382 n AXIS : COUNTMISS (EXT)  383 n AXIS : PULSE MISS (EXT)  384 n AXIS : SOFT PHASE ALARM(EXT)  385 n AXIS : SERIAL DATA ERROR (EXT)  386 n AXIS : DATA TRANS. ERROR (EXT)  387 n AXIS : ABNORMALENCODER (EXT) Servo alarms
  • 15.  400 SERVO ALARM: n–TH AXIS OVERLOAD (Fanuc 16iP Model A/B – 18iP Model B)  401 SERVO ALARM: n–TH AXIS VRDY OFF  402 SERVO ALARM: SV CARD NOT EXIST  403 SERVO ALARM: CARD/SOFTMISMATCH  404 SERVO ALARM: n–TH AXIS VRDY ON  405 SERVO ALARM: (ZERO POINT RETURN FAULT)  407 SERVO ALARM: EXCESS ERROR  409 SERVO ALARM: n AXIS TORQUE ALM  410 SERVO ALARM: n–TH AXIS – EXCESS ERROR  411 SERVO ALARM: n–TH AXIS – EXCESS ERROR  413 SERVO ALARM: n–th AXIS – LSI OVERFLOW  415 SERVO ALARM: n–TH AXIS – EXCESS SHIFT  416 SERVO ALARM: n–TH AXIS – DISCONNECTION(Fanuc 16iP Model A/B – 18iP Model B)  417 SERVO ALARM: n–TH AXIS – PARAMETER INCORRECT  420 SERVO ALARM: n AXIS SYNC TORQUE (M series)  421 SERVO ALARM: n AXIS EXCESS ER (D)  422 SERVO ALARM: n AXIS  423 SERVO ALARM: n AXIS  430 n AXIS : SV. MOTOR OVERHEAT  431 n AXIS : CNV. OVERLOAD  432 n AXIS : CNV. LOW VOLT CONTROL  433 n AXIS : CNV. LOW VOLT DC LINK  434 n AXIS : INV. LOW VOLT CONTROL  435 n AXIS : INV. LOW VOLT DC LINK  436 n AXIS : SOFTTHERMAL (OVC)  437 n AXIS : CNV. OVERCURRENT POWER  438 n AXIS : INV. ABNORMALCURRENT  439 n AXIS : CNV. OVER VOLT DC LINK  440 n AXIS : CNV. EX DECELERATIONPOW.  441 n AXIS : ABNORMALCURRENT OFFSET  442 n AXIS : CNV. CHARGE FAILURE  443 n AXIS : CNV. COOLING FAN FAILURE  444 n AXIS : INV. COOLING FAN FAILURE  445 n AXIS : SOFT DISCONNECT ALARM  446 n AXIS : HARD DISCONNECT ALARM  447 n AXIS : HARD DISCONNECT (EXT)  448 n AXIS : UNMATCHED FEEDBACK ALARM  449 n AXIS : INV. IPM ALARM  453 n AXIS : SPC SOFT DISCONNECT ALARM  460 n AXIS : FSSB DISCONNECT  461 n AXIS : ILLEGALAMP INTERFACE  462 n AXIS : SEND CNC DATA FAILED  463 n AXIS : SEND SLAVE DATA FAILED  464 n AXIS : WRITE ID DATA FAILED
  • 16.  465 n AXIS : READ ID DATA FAILED  466 n AXIS : MOTOR/AMP COMBINATION  467 n AXIS : ILLEGAL SETTING OF AXIS Over travel alarms  500 OVER TRAVEL : +n  501 OVER TRAVEL : –n  502 OVER TRAVEL : +n  503 OVER TRAVEL : –n  504 OVER TRAVEL : +n  505 OVER TRAVEL : –n  506 OVER TRAVEL : +n  507 OVER TRAVEL : –n  508 INTERFERENCE: +n (T series (two–path control))  509 INTERFERENCE: – n (T series (two–path control))  510 OVER TRAVEL: +n  511 OVER TRAVEL: –n Overheat alarms  700 OVERHEAT: CONTROLUNIT  701 OVERHEAT: FAN MOTOR  704 OVERHEAT: SPINDLE Rigid tapping alarms  740 RIGID TAP ALARM: EXCESS ERROR  741 RIGID TAP ALARM: EXCESS ERROR  742 RIGID TAP ALARM: LSI OVER FLOW Serial Spindle alarms  749 S–SPINDLE LSI ERROR  750 SPINDLE SERIAL LINK START FAULT  752 FIRST SPINDLEMODE CHANGE FAULT  754 SPINDLE–1 ABNORMALTORQUE ALM  762 SECOND SPINDLEMODE CHANGE FAULT  764 SPINDLE–2 ABNORMALTORQUE ALM  772 SPINDLE–3MODE CHANGE ERROR  774 SPINDLE–3 ABNORMALTORQUE ALM  782 SPINDLE–4MODE CHANGE ERROR  784 SPINDLE–4 ABNORMALTORQUE ALM Safety zone alarms
  • 17.  4800 ZONE : PUNCHING INHIBITED 1  4801 ZONE : PUNCHING INHIBITED 2  4802 ZONE : PUNCHING INHIBITED 3  4803 ZONE : PUNCHING INHIBITED 4  4804 ZONE : PUNCHING INHIBITED 5 (Fanuc 16iP/18iP Model B)  4805 ZONE : PUNCHING INHIBITED 6 (Fanuc 16iP/18iP Model B)  4806 ZONE : PUNCHING INHIBITED 7 (Fanuc 16iP/18iP Model B)  4807 ZONE : PUNCHING INHIBITED 8 (Fanuc 16iP/18iP Model B)  4810 ZONE : ENTERING INHIBITED 1 +X  4811 ZONE : ENTERING INHIBITED 1 –X  4812 ZONE : ENTERING INHIBITED 2 +X  4813 ZONE : ENTERING INHIBITED 2 –X  4814 ZONE : ENTERING INHIBITED 3 +X  4815 ZONE : ENTERING INHIBITED 3 –X  4816 ZONE : ENTERING INHIBITED 4 +X  4817 ZONE : ENTERING INHIBITED 4 –X  4818 ZONE : ENTERING INHIBITED 5 +X (Fanuc 16iP/18iP Model B)  4819 ZONE : ENTERING INHIBITED 5 (Fanuc 16iP/18iP Model B)  4820 ZONE : ENTERING INHIBITED 6 +X (Fanuc 16iP/18iP Model B)  4821 ZONE : ENTERING INHIBITED 6 (Fanuc 16iP/18iP Model B)  4822 ZONE : ENTERING INHIBITED 7 +X (Fanuc 16iP/18iP Model B)  4823 ZONE : ENTERING INHIBITED 7 –X (Fanuc 16iP/18iP Model B)  4824 ZONE : ENTERING INHIBITED 8 +X (Fanuc 16iP/18iP Model B)  4825 ZONE : ENTERING INHIBITED 8 –X (Fanuc 16iP/18iP Model B)  4830 ZONE : ENTERING INHIBITED 1 +Y  4831 ZONE : ENTERING INHIBITED 1 –Y  4832 ZONE : ENTERING INHIBITED 2 +Y  4833 ZONE : ENTERING INHIBITED 2 –Y  4834 ZONE : ENTERING INHIBITED 3 +Y  4835 ZONE : ENTERING INHIBITED 3 –Y  4836 ZONE : ENTERING INHIBITED 4 +Y  4837 ZONE : ENTERING INHIBITED 4 –Y  4838 ZONE : ENTERING INHIBITED 5 +Y (Fanuc 16iP/18iP Model B)  4839 ZONE : ENTERING INHIBITED 5 –Y (Fanuc 16iP/18iP Model B)  4840 ZONE : ENTERING INHIBITED 6 +Y (Fanuc 16iP/18iP Model B)  4841 ZONE : ENTERING INHIBITED 6 –Y (Fanuc 16iP/18iP Model B)  4842 ZONE : ENTERING INHIBITED 7 +Y (Fanuc 16iP/18iP Model B)  4843 ZONE : ENTERING INHIBITED 7 –Y (Fanuc 16iP/18iP Model B)  4844 ZONE : ENTERING INHIBITED 8 +Y (Fanuc 16iP/18iP Model B)  4845 ZONE : ENTERING INHIBITED 8 –Y (Fanuc 16iP/18iP Model B)  4870 AUTO SETTING FEED ERROR  4871 AUTO SETTING PIECES ERROR  4872 AUTO SETTING COMMAND ERROR System alarms
  • 18.  900 ROM PARITY  910 SRAM PARITY : (BYTE 0)  911 SRAM PARITY : (BYTE 1)  912 DRAM PARITY : (BYTE 0)  913 DRAM PARITY : (BYTE 1)  914 DRAM PARITY : (BYTE 2)  915 DRAM PARITY : (BYTE 3)  916 DRAM PARITY : (BYTE 4)  917 DRAM PARITY : (BYTE 5)  918 DRAM PARITY : (BYTE 6)  919 DRAM PARITY : (BYTE 7)  920 SERVO ALARM(1–4 AXIS)  921 SERVO ALARM(5–8 AXIS)  922 SERVO ALARM(5/6 AXIS) (Fanuc 16iP Model A)  924 SERVOMODULE SETTING ERROR (Fanuc 16iP Model A)  926 FSSB ALARM  930 CPU INTERRUPUT  935 SRAM ECC ERROR  950 PMC SYSTEM ALARM  951 PMCWATCH DOG ALARM  970 NMI OCCURRED IN PMCLSI  971 NMI OCCURRED IN SLC  972 NMI OCCURRED IN OTHER MODULE  973 NON MASK INTERRUPT  974 F–BUS ERROR  975 BUS ERROR  976 L– BUS ERROR