24. Case Study Front Elevation Site Plan The Facts of the Case Municipality: City of Toronto Building Type: Semi-detached dwelling Proposal: Create a second dwelling unit Building Code: Compliance Alternative C134, Option B Developer: Oro Properties
29. Proposed Basement Floor Existing living room changed to a bedroom for the creation of the dwelling unit that occupies the first and basement floor levels New window required for natural light provisions and emergency escape Other issue: Basement Height, minimum room height of not less than 1950 mm over the required floor area and in any location that would normally be used as a means of egress
30. Proposed First Floor Create a 30 minute Fire Separation for the Means of Egress from the dwelling unit on the second floor
31. Proposed Second Floor New Dwelling Unit The construction of the kitchen has created the new second dwelling unit in this building Locating the new kitchen close to the existing bathroom will take advantage of existing drains and vents for the kitchen sink and dishwasher.