SlideShare une entreprise Scribd logo
1  sur  12
Télécharger pour lire hors ligne
Bill Redirect Software
How redirect Digital Calipers or Micrometer Gage
                       Compatible with Mitutoyo products
                                   (Pied à Coulisse digital)




   Use this documentation with the product : Bill Redirect Version 5.0X or more (Rev.: 07/02/2013)
Digital Calipers Software Mitutoyo / Logiciel pour Pied à coulisse Mitutoyo (Serial Port RS232):
   http://www.billproduction.com/Digital%20Calipers%20-%20Pied%20a%20Coulisse%20Digital/index.html

                                Email: info@BillProduction.com
SOFTWARE DESCRIPTION




         BillRedirect software support all kind of RS232 Digital Calipers !
    This professional multi serial port software enables RS232/WiFi Calipers to
     communicate with your current Windows applications. Bill Redirect allows
information to be entered directly into Windows programs as if it was typed in using
                                    the keyboard.



                        •   The measure will appear on a virtual button.
                        •   When this button is clicked,
                        •   The measure will be sent to your application.
                        •   Compatible with Mitutoyo products.

                        No programming or additional hardware required !



           Supported Operating Systems: Windows 98,Me,2000,3000,XP,NT4, Vista, Win 7, Win 8



                   Simply the best Digital Calipers software available !




                                                                                              1
GENERAL INFORMATION

  To configure this software you have to enter in the field password www.billproduction.com, In the
configuration options you have the possibility to change this password for what you want. To close this
                              software, type END in the password field.


           To use some peripheral, for example 2 Calipers, start some instance of the software.
               Use this syntax: Bill_Redirect_Serial_to_KB.exe /#INSTANCE_NAME#

                                   Each instance can have a different configuration !

                            Example: Create a Shortcut instance Caliper_001
                      - Create a shortcut on your desktop to start BillRedirect software
                                                        Shortcut properties:
                                             - In the first field (Target) enter:
    "C:Program FilesBillProductionBill Redirect Serial COM Port to Keyboard BufferBill_Redirect_Serial_to_KB.exe" /#Caliper_001#
                                    - Start my software with this shortcut
                            Example: Create a Shortcut instance Caliper_002
                      - Create a shortcut on your desktop to start BillRedirect software
                                                        Shortcut properties:
                                             - In the first field (Target) enter:
    "C:Program FilesBillProductionBill Redirect Serial COM Port to Keyboard BufferBill_Redirect_Serial_to_KB.exe" /#Caliper_002#
                                         - Start my software with this shortcut


              Don’t forget to push the Save Configuration button to save your current setting.




                                                               If a problem persist or to do more
                                                                                 use our
                                                         Software configuration and integration service
                                                          It's free, fast (usually the same day), and efficient !
                                                         Submit your case to info@billproduction.com
                                                                and receive a customized solution !




                                       Contact by email: info@billproduction.com



                                                                                                                                       2
Configuration step by step
To redirect a Serial RS232 Digital Caliper or Micrometer Gage
          to your application (Compatible with Mitutoyo products)
 (If your peripheral is USB you must install the Virtual Serial Port provided by the manufacturer)

                                          Step #1 (General)




         Disable all except the Serial Port and Virtual Keyboard sections
                               Set to OFF Serial Port




                                                                                                     3
Step #2 (Serial Port Configuration)




                  Click on button: Configuration
                    Set the HandShaking to: NONE
                   Activate the options: DTR and RTS
Enter the Serial Port Number where your Caliper is connected
      If the back color field is GREEN, it’s because the COM is present and available.




                                                                                         4
Step #3 (Virtual Button)

      Create a Virtual Button to receive the Measure from your Caliper




                       Click on button: Configuration




                 To add a New button, click on button: Add




Enter in field “String to send if this button is push”: {TX_KEYB[{BUTTON_TXT[0]}]}




                                                                                     5
Step #4 (Appearance **Optional)
                                               Virtual button appearance:




Button Text: Use this field to set what you want to see on the button.

Button Position: Use this section to change button position.
        * Tips: Activate the NumLock Click the button and use the number 4,6,2 and 8 to change the position.

Button Size : Use this section to change the button size.

Window Title (optional):
        Option “Window Title” Description: With this option each button of your Virtual Keyboard can appear and disappear
        when a specific window title is activate.
        *Example: If the window title is “Application measure expert Version 1.2b” and in the field “Window Title” you enter
                     “Measure EXPERT” then each time that this window take the focus this button is visible.
         * To enter more of one window title, separate the title name by a comas:
                   Example: Measure EXPERT, NOTEPAD, PAGE COUNT
        * If this the field “Window Title” is blank, then the button is always visible.

Color (optional): Use this option to change the button back color.

Font (optional): Use this option to change the button text font.

Picture (optional): Use this section to:
        Paste the picture from the ClipBoard to the button.
        Clear the picture button.
        Load the picture button.


                                                                                                                           6
Step #5




                        Click on: Configuration




           Click on button: ADD and choose one of two options

                To receive the value on the virtual button:
                     In the field “Search” enter: {SERIAL_RX}
      In the field “Replace by” enter: {TX_BUTTON_TXT[0,RX_DATA]}

                                      or

To receive the value on Keyboard Buffer as if it had been typed at the keyboard:
                      In the field “Search” enter: {SERIAL_RX}
             In the field “Replace by” enter: {TX_KEYB[RX_DATA]}
               *Disable the section Virtual Keyboard on Main Screen




                                                                                   7
Step #6 (Test)
                                    TEST YOUR Digital Caliper


                         On Main Screen click on: Save Configuration




                               Click on button: Minimize button
                                Connect and start your Caliper
If everything works well, you should see the measure in real-time directly on the virtual button.

                                 Open the Windows: NotePad
                                 Click on your: Virtual Button

                       Examples of what you should receive on the button:
                                     01A+001.8735
                                      47, 1.8735, ,01
                                       1.8735,inch,A

             If nothing appear, try to click on button directly on your Caliper



                       • The measure should appear on the virtual button.
                       • When this button is clicked,
                       • The measure should be sent to the current application.




                                           If a problem persist or to do more
                                                               use our
                                       Software configuration and integration service
                                        It's free, fast (usually the same day), and efficient !
                                       Submit your case to info@billproduction.com
                                              and receive a customized solution !


                                                                                                    8
Step #7 (Optional)
                                        DATA FILTERING CONFIGURATION




                                               Click on: Configuration




The Prefix/Sufix (optional):
       When the software receive data from the Caliper, it add the PREFIX at the beginning of data and the Sufix at the end.
       [Prefix][data from a peripheral][Sufix]
       The Prefix and the Sufix can contain any characters and or commands that you want.
       *see possible commands section in the bill redirect manual

The Remove ASCII section (optional):
       With this section you can remove ASCII characters directly from the received measure.
       With the button Add you can add a new ASCII characters from 0 to 255.
       *For example: To remove Enter, ADD: 13
       *For example: To remove Line Feed, ADD: 10
       *For example: To remove Spaces, ADD: 32




                                                                                                                               9
Step #8 (Optional Filtering examples)




           Click on button ADD to add a rule
and move this new rule in first position with the UP arrow
     Example 1: On all data received: From the position 6 extract 7 characters
                   Search                               Replace by

            {SERIAL_RX}               {STRING_MID[RX_DATA,6,7]}



                           Example 2: To remove the spaces
                   Search                               Replace by

               {ASCII:32}

                            Example 3: To remove text: inch
                   Search                               Replace by

                    inch

                  Example 4: To remove carriage return line feed
                   Search                               Replace by

              {ASCII:13}
              {ASCII:10}

                       Example 5: To receive only the value
                   Search                               Replace by

           { SERIAL _RX}                 {MULTIPLY[RX_DATA,1,#.00]}

      Example 6: On all data received: From the right extract last 5 characters
                   Search                               Replace by

           { SERIAL _RX}                 {STRING_RIGHT[RX_DATA,5]}




                                                                                  10
To receive the data in real time to a existing Excel file,



      install our Excel Plugin: http://www.billproduction.com/Plugin_DDE.zip
Use this documentation: http://www.billproduction.com/Bill_DDE_over_Ethernet.pdf




               For more documentation visit:
     http://www.billproduction.com/documentation.html




                                   If a problem persist or to do more
                                                       use our
                               Software configuration and integration service
                                It's free, fast (usually the same day), and efficient !
                               Submit your case to info@billproduction.com
                                      and receive a customized solution !




                                                                                          11

Contenu connexe

Similaire à Digital Calipers Software Mitutoyo / Logiciel pour Pied à coulisse Mitutoyo (Serial Port RS232)

Automatic dimmer package dimensioning RS-232
Automatic dimmer package dimensioning RS-232Automatic dimmer package dimensioning RS-232
Automatic dimmer package dimensioning RS-232
topomax
 
Control Relays via RS-232 / USB
Control Relays via RS-232 / USBControl Relays via RS-232 / USB
Control Relays via RS-232 / USB
topomax
 
How support caller Id phone number with a modem
How support caller Id phone number with a modemHow support caller Id phone number with a modem
How support caller Id phone number with a modem
topomax
 
How support caller ID phone number
How support caller ID phone numberHow support caller ID phone number
How support caller ID phone number
topomax
 
Your peripherals RS232 USB and Excel
Your peripherals RS232 USB and ExcelYour peripherals RS232 USB and Excel
Your peripherals RS232 USB and Excel
topomax
 
Control relay via schedule time
Control relay via schedule timeControl relay via schedule time
Control relay via schedule time
topomax
 
Full screen Web Browser support RS-232 / TCPIP peripheral (plugin)
Full screen Web Browser support RS-232 / TCPIP peripheral (plugin)Full screen Web Browser support RS-232 / TCPIP peripheral (plugin)
Full screen Web Browser support RS-232 / TCPIP peripheral (plugin)
topomax
 
Bill serial monitor_manual_en
Bill serial monitor_manual_enBill serial monitor_manual_en
Bill serial monitor_manual_en
danysaju_1
 
Bill redirect manual
Bill redirect manualBill redirect manual
Bill redirect manual
topomax
 
RS232 barcode scanner Proximity reader on a specific field in your application
RS232 barcode scanner Proximity reader on a specific field in your applicationRS232 barcode scanner Proximity reader on a specific field in your application
RS232 barcode scanner Proximity reader on a specific field in your application
topomax
 
Bill redirect multiply
Bill redirect multiplyBill redirect multiply
Bill redirect multiply
topomax
 
Microsoft Excel and peripheral via VBA DDE (RS-232, TCPIP, USB, UDP ...)
Microsoft Excel and peripheral via VBA DDE (RS-232, TCPIP, USB, UDP ...)Microsoft Excel and peripheral via VBA DDE (RS-232, TCPIP, USB, UDP ...)
Microsoft Excel and peripheral via VBA DDE (RS-232, TCPIP, USB, UDP ...)
topomax
 
Support Awid proximity reader
Support Awid proximity readerSupport Awid proximity reader
Support Awid proximity reader
topomax
 
Review chapter 1 3 part 2
Review chapter 1 3 part 2Review chapter 1 3 part 2
Review chapter 1 3 part 2
cbrmiller
 
Windows Virtual Keyboard modification
Windows Virtual Keyboard modificationWindows Virtual Keyboard modification
Windows Virtual Keyboard modification
topomax
 

Similaire à Digital Calipers Software Mitutoyo / Logiciel pour Pied à coulisse Mitutoyo (Serial Port RS232) (20)

Automatic dimmer package dimensioning RS-232
Automatic dimmer package dimensioning RS-232Automatic dimmer package dimensioning RS-232
Automatic dimmer package dimensioning RS-232
 
Control Relays via RS-232 / USB
Control Relays via RS-232 / USBControl Relays via RS-232 / USB
Control Relays via RS-232 / USB
 
How support caller Id phone number with a modem
How support caller Id phone number with a modemHow support caller Id phone number with a modem
How support caller Id phone number with a modem
 
How support caller ID phone number
How support caller ID phone numberHow support caller ID phone number
How support caller ID phone number
 
Your peripherals RS232 USB and Excel
Your peripherals RS232 USB and ExcelYour peripherals RS232 USB and Excel
Your peripherals RS232 USB and Excel
 
Control relay via schedule time
Control relay via schedule timeControl relay via schedule time
Control relay via schedule time
 
Full screen Web Browser support RS-232 / TCPIP peripheral (plugin)
Full screen Web Browser support RS-232 / TCPIP peripheral (plugin)Full screen Web Browser support RS-232 / TCPIP peripheral (plugin)
Full screen Web Browser support RS-232 / TCPIP peripheral (plugin)
 
Bill serial monitor_manual_en
Bill serial monitor_manual_enBill serial monitor_manual_en
Bill serial monitor_manual_en
 
Bill redirect manual
Bill redirect manualBill redirect manual
Bill redirect manual
 
RS232 barcode scanner Proximity reader on a specific field in your application
RS232 barcode scanner Proximity reader on a specific field in your applicationRS232 barcode scanner Proximity reader on a specific field in your application
RS232 barcode scanner Proximity reader on a specific field in your application
 
Bill redirect multiply
Bill redirect multiplyBill redirect multiply
Bill redirect multiply
 
Microsoft Excel and peripheral via VBA DDE (RS-232, TCPIP, USB, UDP ...)
Microsoft Excel and peripheral via VBA DDE (RS-232, TCPIP, USB, UDP ...)Microsoft Excel and peripheral via VBA DDE (RS-232, TCPIP, USB, UDP ...)
Microsoft Excel and peripheral via VBA DDE (RS-232, TCPIP, USB, UDP ...)
 
Support Awid proximity reader
Support Awid proximity readerSupport Awid proximity reader
Support Awid proximity reader
 
CodePool Liverpool 2013 - Microsoft Gadgeteer Presentation
CodePool Liverpool 2013 - Microsoft Gadgeteer PresentationCodePool Liverpool 2013 - Microsoft Gadgeteer Presentation
CodePool Liverpool 2013 - Microsoft Gadgeteer Presentation
 
Review chapter 1 3 part 2
Review chapter 1 3 part 2Review chapter 1 3 part 2
Review chapter 1 3 part 2
 
Windows Virtual Keyboard modification
Windows Virtual Keyboard modificationWindows Virtual Keyboard modification
Windows Virtual Keyboard modification
 
Remote control adding
Remote control addingRemote control adding
Remote control adding
 
RCCreator Guidance. Remote control adding (copy codes from your original remo...
RCCreator Guidance. Remote control adding (copy codes from your original remo...RCCreator Guidance. Remote control adding (copy codes from your original remo...
RCCreator Guidance. Remote control adding (copy codes from your original remo...
 
CIS 170 Become Exceptional--cis170.com
CIS 170 Become Exceptional--cis170.comCIS 170 Become Exceptional--cis170.com
CIS 170 Become Exceptional--cis170.com
 
Toyotaotcvimgtssoftwareoverview 160525025652
Toyotaotcvimgtssoftwareoverview 160525025652Toyotaotcvimgtssoftwareoverview 160525025652
Toyotaotcvimgtssoftwareoverview 160525025652
 

Plus de topomax

Windows Telnet Server for your mobile devices, RF Terminal data acquisiiton B...
Windows Telnet Server for your mobile devices, RF Terminal data acquisiiton B...Windows Telnet Server for your mobile devices, RF Terminal data acquisiiton B...
Windows Telnet Server for your mobile devices, RF Terminal data acquisiiton B...
topomax
 
Serial RS232 to Keyboard wedge software
Serial RS232 to Keyboard wedge softwareSerial RS232 to Keyboard wedge software
Serial RS232 to Keyboard wedge software
topomax
 
Bill redirect manual_fr
Bill redirect manual_frBill redirect manual_fr
Bill redirect manual_fr
topomax
 
Microsoft Excel and RS-232 peripherals protocol communication DDE
Microsoft Excel and RS-232 peripherals protocol communication DDEMicrosoft Excel and RS-232 peripherals protocol communication DDE
Microsoft Excel and RS-232 peripherals protocol communication DDE
topomax
 
iPod iPhone iPod Remote control via TCPIP
iPod iPhone iPod Remote control via TCPIPiPod iPhone iPod Remote control via TCPIP
iPod iPhone iPod Remote control via TCPIP
topomax
 
Storm Keyboard / Keypad RS-232 Wedge keyboard solution
Storm Keyboard / Keypad RS-232  Wedge keyboard solutionStorm Keyboard / Keypad RS-232  Wedge keyboard solution
Storm Keyboard / Keypad RS-232 Wedge keyboard solution
topomax
 
Microsoft access VBA communication with RS232 Peripherals
Microsoft access VBA  communication with RS232 PeripheralsMicrosoft access VBA  communication with RS232 Peripherals
Microsoft access VBA communication with RS232 Peripherals
topomax
 
Bill redirect field
Bill redirect fieldBill redirect field
Bill redirect field
topomax
 

Plus de topomax (9)

Logiciel pour Balance RS232 redirige le poids dans votre application
Logiciel pour Balance RS232 redirige le poids dans votre applicationLogiciel pour Balance RS232 redirige le poids dans votre application
Logiciel pour Balance RS232 redirige le poids dans votre application
 
Windows Telnet Server for your mobile devices, RF Terminal data acquisiiton B...
Windows Telnet Server for your mobile devices, RF Terminal data acquisiiton B...Windows Telnet Server for your mobile devices, RF Terminal data acquisiiton B...
Windows Telnet Server for your mobile devices, RF Terminal data acquisiiton B...
 
Serial RS232 to Keyboard wedge software
Serial RS232 to Keyboard wedge softwareSerial RS232 to Keyboard wedge software
Serial RS232 to Keyboard wedge software
 
Bill redirect manual_fr
Bill redirect manual_frBill redirect manual_fr
Bill redirect manual_fr
 
Microsoft Excel and RS-232 peripherals protocol communication DDE
Microsoft Excel and RS-232 peripherals protocol communication DDEMicrosoft Excel and RS-232 peripherals protocol communication DDE
Microsoft Excel and RS-232 peripherals protocol communication DDE
 
iPod iPhone iPod Remote control via TCPIP
iPod iPhone iPod Remote control via TCPIPiPod iPhone iPod Remote control via TCPIP
iPod iPhone iPod Remote control via TCPIP
 
Storm Keyboard / Keypad RS-232 Wedge keyboard solution
Storm Keyboard / Keypad RS-232  Wedge keyboard solutionStorm Keyboard / Keypad RS-232  Wedge keyboard solution
Storm Keyboard / Keypad RS-232 Wedge keyboard solution
 
Microsoft access VBA communication with RS232 Peripherals
Microsoft access VBA  communication with RS232 PeripheralsMicrosoft access VBA  communication with RS232 Peripherals
Microsoft access VBA communication with RS232 Peripherals
 
Bill redirect field
Bill redirect fieldBill redirect field
Bill redirect field
 

Digital Calipers Software Mitutoyo / Logiciel pour Pied à coulisse Mitutoyo (Serial Port RS232)

  • 1. Bill Redirect Software How redirect Digital Calipers or Micrometer Gage Compatible with Mitutoyo products (Pied à Coulisse digital) Use this documentation with the product : Bill Redirect Version 5.0X or more (Rev.: 07/02/2013) Digital Calipers Software Mitutoyo / Logiciel pour Pied à coulisse Mitutoyo (Serial Port RS232): http://www.billproduction.com/Digital%20Calipers%20-%20Pied%20a%20Coulisse%20Digital/index.html Email: info@BillProduction.com
  • 2. SOFTWARE DESCRIPTION BillRedirect software support all kind of RS232 Digital Calipers ! This professional multi serial port software enables RS232/WiFi Calipers to communicate with your current Windows applications. Bill Redirect allows information to be entered directly into Windows programs as if it was typed in using the keyboard. • The measure will appear on a virtual button. • When this button is clicked, • The measure will be sent to your application. • Compatible with Mitutoyo products. No programming or additional hardware required ! Supported Operating Systems: Windows 98,Me,2000,3000,XP,NT4, Vista, Win 7, Win 8 Simply the best Digital Calipers software available ! 1
  • 3. GENERAL INFORMATION To configure this software you have to enter in the field password www.billproduction.com, In the configuration options you have the possibility to change this password for what you want. To close this software, type END in the password field. To use some peripheral, for example 2 Calipers, start some instance of the software. Use this syntax: Bill_Redirect_Serial_to_KB.exe /#INSTANCE_NAME# Each instance can have a different configuration ! Example: Create a Shortcut instance Caliper_001 - Create a shortcut on your desktop to start BillRedirect software Shortcut properties: - In the first field (Target) enter: "C:Program FilesBillProductionBill Redirect Serial COM Port to Keyboard BufferBill_Redirect_Serial_to_KB.exe" /#Caliper_001# - Start my software with this shortcut Example: Create a Shortcut instance Caliper_002 - Create a shortcut on your desktop to start BillRedirect software Shortcut properties: - In the first field (Target) enter: "C:Program FilesBillProductionBill Redirect Serial COM Port to Keyboard BufferBill_Redirect_Serial_to_KB.exe" /#Caliper_002# - Start my software with this shortcut Don’t forget to push the Save Configuration button to save your current setting. If a problem persist or to do more use our Software configuration and integration service It's free, fast (usually the same day), and efficient ! Submit your case to info@billproduction.com and receive a customized solution ! Contact by email: info@billproduction.com 2
  • 4. Configuration step by step To redirect a Serial RS232 Digital Caliper or Micrometer Gage to your application (Compatible with Mitutoyo products) (If your peripheral is USB you must install the Virtual Serial Port provided by the manufacturer) Step #1 (General) Disable all except the Serial Port and Virtual Keyboard sections Set to OFF Serial Port 3
  • 5. Step #2 (Serial Port Configuration) Click on button: Configuration Set the HandShaking to: NONE Activate the options: DTR and RTS Enter the Serial Port Number where your Caliper is connected If the back color field is GREEN, it’s because the COM is present and available. 4
  • 6. Step #3 (Virtual Button) Create a Virtual Button to receive the Measure from your Caliper Click on button: Configuration To add a New button, click on button: Add Enter in field “String to send if this button is push”: {TX_KEYB[{BUTTON_TXT[0]}]} 5
  • 7. Step #4 (Appearance **Optional) Virtual button appearance: Button Text: Use this field to set what you want to see on the button. Button Position: Use this section to change button position. * Tips: Activate the NumLock Click the button and use the number 4,6,2 and 8 to change the position. Button Size : Use this section to change the button size. Window Title (optional): Option “Window Title” Description: With this option each button of your Virtual Keyboard can appear and disappear when a specific window title is activate. *Example: If the window title is “Application measure expert Version 1.2b” and in the field “Window Title” you enter “Measure EXPERT” then each time that this window take the focus this button is visible. * To enter more of one window title, separate the title name by a comas: Example: Measure EXPERT, NOTEPAD, PAGE COUNT * If this the field “Window Title” is blank, then the button is always visible. Color (optional): Use this option to change the button back color. Font (optional): Use this option to change the button text font. Picture (optional): Use this section to: Paste the picture from the ClipBoard to the button. Clear the picture button. Load the picture button. 6
  • 8. Step #5 Click on: Configuration Click on button: ADD and choose one of two options To receive the value on the virtual button: In the field “Search” enter: {SERIAL_RX} In the field “Replace by” enter: {TX_BUTTON_TXT[0,RX_DATA]} or To receive the value on Keyboard Buffer as if it had been typed at the keyboard: In the field “Search” enter: {SERIAL_RX} In the field “Replace by” enter: {TX_KEYB[RX_DATA]} *Disable the section Virtual Keyboard on Main Screen 7
  • 9. Step #6 (Test) TEST YOUR Digital Caliper On Main Screen click on: Save Configuration Click on button: Minimize button Connect and start your Caliper If everything works well, you should see the measure in real-time directly on the virtual button. Open the Windows: NotePad Click on your: Virtual Button Examples of what you should receive on the button: 01A+001.8735 47, 1.8735, ,01 1.8735,inch,A If nothing appear, try to click on button directly on your Caliper • The measure should appear on the virtual button. • When this button is clicked, • The measure should be sent to the current application. If a problem persist or to do more use our Software configuration and integration service It's free, fast (usually the same day), and efficient ! Submit your case to info@billproduction.com and receive a customized solution ! 8
  • 10. Step #7 (Optional) DATA FILTERING CONFIGURATION Click on: Configuration The Prefix/Sufix (optional): When the software receive data from the Caliper, it add the PREFIX at the beginning of data and the Sufix at the end. [Prefix][data from a peripheral][Sufix] The Prefix and the Sufix can contain any characters and or commands that you want. *see possible commands section in the bill redirect manual The Remove ASCII section (optional): With this section you can remove ASCII characters directly from the received measure. With the button Add you can add a new ASCII characters from 0 to 255. *For example: To remove Enter, ADD: 13 *For example: To remove Line Feed, ADD: 10 *For example: To remove Spaces, ADD: 32 9
  • 11. Step #8 (Optional Filtering examples) Click on button ADD to add a rule and move this new rule in first position with the UP arrow Example 1: On all data received: From the position 6 extract 7 characters Search Replace by {SERIAL_RX} {STRING_MID[RX_DATA,6,7]} Example 2: To remove the spaces Search Replace by {ASCII:32} Example 3: To remove text: inch Search Replace by inch Example 4: To remove carriage return line feed Search Replace by {ASCII:13} {ASCII:10} Example 5: To receive only the value Search Replace by { SERIAL _RX} {MULTIPLY[RX_DATA,1,#.00]} Example 6: On all data received: From the right extract last 5 characters Search Replace by { SERIAL _RX} {STRING_RIGHT[RX_DATA,5]} 10
  • 12. To receive the data in real time to a existing Excel file, install our Excel Plugin: http://www.billproduction.com/Plugin_DDE.zip Use this documentation: http://www.billproduction.com/Bill_DDE_over_Ethernet.pdf For more documentation visit: http://www.billproduction.com/documentation.html If a problem persist or to do more use our Software configuration and integration service It's free, fast (usually the same day), and efficient ! Submit your case to info@billproduction.com and receive a customized solution ! 11