La tecnología de soporte extracorpóreo se desarrolló en el campo de la cirugía cardiaca hacia finales de la década del 40.
Dr. Alberto Díaz Seminario
Médico Intensivista
alberto06ds@yahoo.es
1. Extracorporeal LifeExtracorporeal Life
Suport (ECLS) for AdultSuport (ECLS) for Adult
Respiratory FailureRespiratory Failure
Dr. Alberto Díaz SeminarioDr. Alberto Díaz Seminario
Médico IntensivistaMédico Intensivista
Hospital Nacional Edgardo RebagliatiHospital Nacional Edgardo Rebagliati
UCI 2° C – – ESSALUDUCI 2° C – – ESSALUD
alberto06ds@yahoo.es
2. Evolución del ECLS
La tecnología de soporte
extracorpóreo se desarrolló en el
campo de la cirugía cardiaca hacia
finales de la década del 40.
Gibbon y col. Sistema de soporte
Cardiovascular durante cirugía
cardiaca:
Bomba con rodillos: perfusión
Cilindro verticalmente montado
sobre el flujo sanguineo:
intercambiador de CO2 y O2
entre una fina capa de sangre y
el aire ambiental
(1937 Arch Surg 34: 1105)
3. Evolución del ECLS
El intercambio gaseoso a través de
oxigenadores de burbuja o de
membrana permite el soporte
cardiopulmonar total por algunas
horas
La producción de hemólisis debido al
contacto directo entre la sangre y la
fase gaseosa constituye el mayor
factor limitante del tiempo de
exposición
Busqueda del mejor oxigenador:
De burbujas
De disco
De membrana
De fibra hueca
4. Evolución del ECLS
Década del ’60, la investigación en
oxigenación extracorpórea con oxigenador de
membrana (ECMO) se dedicó a desarrollar
varios oxigenadores de membrana que
permitieran la mejor interface en términos de
intercambio gaseoso y biocompatibilidad.
Separación de las faces hemática y gaseosa
por un oxigenador de membrana
Disminuye el daño de los componentes de
la sangre
Permite un tiempo más prolongado de
perfusión.
La aplicación del soporte extracorpóreo se
extendió a la asistencia prolongada de
pacientes con insuficiencia respiratoria aguda.
5. Evolución del ECLS
1972: Hill y col. Primer éxito en un adulto con
soporte Extracorporeo prolongado (75 horas).
Politraumatizado de 24 años IRA
postoperatoria de reparación de aorta
N Engl J Med 1972; 286: 629
1976: Barlett. Preimer éxito en RN con SDRN
1979: Zapol y col. Multicéntrico avalado por
NIH (ECMO vs. VM convencional en
Insuficiencia Respiratoria).
JAMA 1979; 242: 2193
Mortalidad de 90% en ambos grupos
Se abandono el uso de ECMO para falla
respiratoria
6. Evolución del ECLS
1986: Gattinoni y col. Técnica de
perfusión extracorporea con criterios
de inclusión similares a los de Zapol.
Umbral de entrada con mortalidad
predecible del 80%
Bajo flujo
Acceso vascular percutáneo
Eliminación aumentada de CO2
(ECCO2R)
Supervivencia 48.8%
Se retoma uso de ECLS para falla
respiratoria
JAMA 1986; 256: 881
7. Extracorporeal Life Support Organization
1989 se formó The Extracorporeal
Life Support Organization (ELSO)
Grupo de centros que utilizan en
forma activa el soporte vital
extracorpóreo (ECLS) en el manejo
de la falla cardiopulmonar.
Dentro de las funciones del ELSO
se encuentran:
aumentar la comunicación
desarrollar guías para soporte
extracorpóreo
mantener un registro de los
casos de ECLS
9. Terminologia
ECMO: Oxigenación extracorpórea con oxigenador de membrana se refiere al empleo
de un bypass de alto flujo que destaca los aspectos de la oxigenación durante el soporte
extracorpóreo.
VA-ECMO: El bypass es veno-arterial
VV-ECMO: El bypass es veno-venoso
10. Terminologia
ECMO: Oxigenación extracorpórea con oxigenador de membrana se refiere al empleo
de un bypass de alto flujo que destaca los aspectos de la oxigenación durante el soporte
extracorpóreo.
VA-ECMO: El bypass es veno-arterial
VV-ECMO: El bypass es veno-venoso
ECCO2R : Remoción extracorpórea de CO2. Empleo de un bypass veno-venoso de
bajo flujo, que utiliza el 20-30% del volumen minuto cardíaco, requerido para remover
totalmente el CO2 producido.
PECCO2R: Si se realiza sólo una remoción parcial del CO2, como ocurre en pacientes
que respiran espontáneamente con enfermedades pulmonares crónicas,
11. Terminologia
ECMO: Oxigenación extracorpórea con oxigenador de membrana se refiere al empleo
de un bypass de alto flujo que destaca los aspectos de la oxigenación durante el soporte
extracorpóreo.
VA-ECMO: El bypass es veno-arterial
VV-ECMO: El bypass es veno-venoso
ECCO2R : Remoción extracorpórea de CO2. Empleo de un bypass veno-venoso de
bajo flujo, que utiliza el 20-30% del volumen minuto cardíaco, requerido para remover
totalmente el CO2 producido.
PECCO2R: Si se realiza sólo una remoción parcial del CO2, como ocurre en pacientes
que respiran espontáneamente con enfermedades pulmonares crónicas,
ECLS: Tratando de uniformar la terminología, Bartlett acuñó el término soporte vital
extracorpóreo , que incluye todas las técnicas que utilizan un pulmón artificial para
soportara pacientes con insuficiencia respiratoria o cardiaca
12. Fisiología de la oxigenación por
membrana extracorporea
Objetivo: transporte adecuado de
oxígeno a los tejidos.
ECMO garantiza, el contenido de
oxígeno en la sangre al poder
saturarse la hemoglobina
extracorporalmente y no depender
de la función pulmonar primitiva del
paciente.
La cantidad de sangre oxigenada que
el ECMO envía al torrente
sanguíneo asegura el transporte de
oxígeno
Ambas variables del transporte de
oxígeno se aseguran en ECMO de forma
independiente.
Éste depende en circunstancias normales
de un adecuado contenido de oxígeno en
la sangre y de un gasto cardiaco suficiente.
La capacidad de transportar oxígeno por
la sangre es función de la concentración
de la hemoglobina y de su saturación de
oxígeno, no teniendo apenas
trascendencia la cantidad de oxígeno
disuelto en la sangre (PaO2).
El lavado de CO2 se realiza
también extracorporalmente y es
función de la relación ventilación-
perfusión del oxigenador, de tal
manera que puede también
regularse independientemente y
mantener el pulmón del paciente
en apnea o ventilación mínima
para reducir injuria pulmonar
13. Fisiología de la oxigenación por
membrana extracorporea
En ECMO, a diferencia de la circulación
extracorpórea, se mantiene la fisiología normal del
paciente en normotermia, con un consumo de
oxígeno normal.
El asegurar el consumo de O2 es el objetivo
durante el manejo del ECMO.
Varias son las variables que indican de manera
indirecta este adecuado consumo de O2.
La medición continua de la saturación en la
línea de retorno venoso del paciente es una
forma indirecta de conocer la saturación venosa
mixta y, por lo tanto, de conocer el porcentaje
de extracción periférica de O2.
En condiciones normales, el transporte de O2
es superior al necesario para asegurar el
consumo celular de oxígeno y puede descender
sin que el consumo se encuentre limitado.
14. Fisiología de la oxigenación por
membrana extracorporea
El mantenimiento de un flujo suficiente de
sangre oxigenada con ECMO garantiza el
transporte de O2 cuando el paciente es incapaz
de realizarlo, y el marcador de que este flujo
de sangre oxigenada desde ECMO es
suficiente es una saturación de O2 en el
retorno venoso superior al 75%.
En situaciones de gasto cardiaco elevado como
shock séptico es necesario mantener flujos
mayores con saturaciones venosas superiores
en ocasiones al 80%.
En pacientes con cardiopatías con mezcla
interauricular o corazón univentricular, este
marcador no es tan adecuado ya que la
contaminación de sangre que procede del
retorno de las venas pulmonares interfiere con
la interpretación de la saturación venosa.
Canulación V-A
15. Fisiología de la oxigenación por
membrana extracorporea
ECMO veno-venoso: objetivo es sustituir la
función respiratoria.
Debido a la alta capacidad de eliminar CO2
por el ECMO, el paciente puede quedar en
apnea durante el tiempo de ECMO veno-
venoso.
Al entregarse la sangre oxigenada al territorio
sistémico venoso, la saturación del paciente en
ECMO veno-venoso con incapacidad de
oxigenar por su pulmón primitivo es en
general próxima al 85-88%, suficiente para
garantizar un adecuado transporte de O2.
Según la función del pulmón primitivo va
mejorando, la saturación arterial de oxígeno
del paciente va aumentando, siendo éste el
marcador, junto con el incremento del CO2
espirado en la vía aérea, de la mejoría
respiratoria.
16.
17. Metodología
Cualquiera que sea la técnica utilizada, un circuito de
asistencia extracorpórea incluye:
El acceso vascular utilizado: venoarterial (VA) o
venovenoso (VV).
En caso de requerirse exclusivamente
soporte respiratorio, se prefiere el acceso
VV
Si se requiere un soporte hemodinámico,
se recurre a un acceso VA
La cantidad de flujo sanguíneo extracorpóreo
(ECBF) en relación con el volumen minuto
cardíaco (CO). Cuanto mayor sea la relación
ECBF/CO mayor será la contribución del
sistema extracorpóreo a la oxigenación.
El manejo ventilatorio asociado del paciente
18. Metodologia actual más empleada
En la actualidad se tienden a utilizar
sistemas con bypass venovenoso de
bajo flujo
La sangre venosa es drenada desde la
vena cava inferior a través de catéteres
insertados por vía percutanea a nivel de
las venas femorales.
La sangre oxigenada es retornada a la
vena cava superior a través de un
catéter que se avanza por vía
percutanea a través de la vena yugular
interna hasta la vena cava superior.
Se establece un bypass venovenoso
femoral-yugular utilizando bombas de
circulación y oxigenadores en línea.
19. RESULTADOSRESULTADOS
¿ Es el ECLS mejor que el¿ Es el ECLS mejor que el
tratamiento convencional ?tratamiento convencional ?
20. Pacientes
ECMO blood gas criteria
Established by the ECMO trial.
ECMO blood gas criteria included the following:
1. PaO, 50 mm Hg for at least 2 hours at an inspired oxygen fraction (Flo,) of
1.0 and positive end-expiratory pressure (PEEP) of 5 cm H,O (fast entry
criteria),
or
2. PaO, 50 mm Hg for at least 12 hours at an Flo, 0.6 and PEEP 5 cm H,O after
48 hours of ICU care with attention to all correctable problems (slow entry
criteria).
21. 1979
Extracorporeal membrane oxygenation in
severe acute respiratory failure. A
randomized prospective study
JAMA, Vol. 242 No. 20, November 16, 1979
W. M. Zapol, M. T. Snider, J. D. Hill, R. J. Fallat, R. H. Bartlett, L. H.
Edmunds, A. H. Morris, E. C. Peirce 2nd, A. N. Thomas, H. J. Proctor,
P. A. Drinker, P. C. Pratt, A. Bagniewski and R. G. Miller Jr
22. Nine medical centers collaborated in a
prospective randomized study to
evaluate prolonged extracorporeal
membrane oxygenation (ECMO) as a
therapyfor severe acute respiratory
failure (ARF).
Ninety adult patients wereselected by
common criteria of arterial hypoxemia
and treated with eitherconventional
mechanical ventilation (48 patients) or
mechanical ventilationsupplemented
with partial venoarterial bypass (42
patients).
Four patientsin each group survived.
We conclude that ECMO can support
respiratory gas exchange butdid not
increase the probability of long-term
survival in patients withsevere ARF
Extracorporeal membrane oxygenation
in severe acute respiratory failure. A
randomized prospective study
The majority of patients suffered
acute bacterial or viral pneumonia
(57%).
All nine patients with pulmonary
embolism and six patients with
posttraumatic acute respiratory
failure died.
The majority of patients died of
progressive reduction of
transpulmonary gas exchange and
decreased compliance due to diffuse
pulmonary inflammation, necrosis,
and fibrosis.
We conclude that ECMO can support
respiratory gas exchange but did not
increase the probability of long-term
survival in patients with severe ARF
23. Extracorporeal membrane oxygenation
in severe acute respiratory failure. A
randomized prospective study
Multicentrico: 11
Avalado por NIH
ECMO vs. VM convencional en SDRA
Técnica: By-pass veno-arterial
300 pacientes IRA
48 pacientes
VM CONVENCIONAL
42 pacientes
VM + By-pass VA(ECMO)
92 90 pacientes IRA severa (ARDS)
4 pacientes 4 pacientesSupervivientes :
24. Low-frequency positive-pressure ventilation
with extracorporeal CO2 removal in severe
acute respiratory failure
Vol. 256 No. 7, August 15, 1986
L. Gattinoni, A. Pesenti, D. Mascheroni, R. Marcolin, R. Fumagalli, F.
Rossi, G. Iapichino, G. Romagnoli, L. Uziel, A. Agostoni and al. et
1986
25. Low-frequency positive-pressure ventilation with
extracorporeal CO2 removal in severe acute
respiratory failure
43 patients were entered in an uncontrolled study designed toevaluate
extracorporeal membrane lung support in severe ARF of parenchymal origin.
Most of the metabolic carbon dioxideproduction was cleared through a low-flow
venovenous bypass.
To avoid lunginjury from conventional mechanical ventilation, the lungs were kept
"atrest" (three to five breaths per minute) at a low peak airway pressure of35 to
45 cm H2O.
The entry criteria were based on gasexchange under standard ventilatory
conditions (expected mortality rate > 90%).
Lung function improved in 31 patients (72.8%),and 21 patients (48.8%)
eventually survived.
The mean time on bypass forthe survivors was 5.4 +/- 3.5 days. Improvement in
lung function, whenpresent, always occurred within 48 hours. Blood loss averaged
1800 +/- 850mL/d.
No major technical accidents occurred in more than 8000 hours ofperfusion.
Extracorporeal carbon dioxide removal with low-frequencyventilation proved a
safe technique, and we suggest it as a valuable tooland an alternative to treating
severe acute respiratory failure byconventional means.
26. Low-frequency positive-pressure ventilation with
extracorporeal CO2 removal in severe acute
respiratory failure
Estudio no controlado
Técnica: perfusión extracorporea de bajo flujo con acceso
vascular percutáneo
Eliminación aumentada de dióxido de carbono (ECCO2)
Umbral de entrada: mortalidad predecible mayor de 90%
43 pacientes ECMO V-V +
VM: FR: 3-5
PP: 35 -45
SUPERVIVIENTES:
21 PACIENTES
48.8%
29. Extracorporeal Life Support
The University of Michigan Experience
2000;283:904-908.
Robert H. Bartlett, MD; Dietrich W. Roloff, MD; Joseph R. Custer, MD;
John G. Younger, MD; Ronald B. Hirschl, MD
30. Extracorporeal Life Support
The University of Michigan Experience
The University of Michigan experience with extracorporeal life
support (ECLS)
1000 consecutive patients between 1980 and1998
Survival to hospital discharge
Respiratory failure
88% in 586neonates
70% in 132 children
56% in 146 adults.
Cardiac failure
48% in 105
children
33% in 31
adults.
31. Extracorporeal Life Support
The University of Michigan Experience
Universidad de Michigan
Grupo trabaja especificamente
con técnica V-A (Hemmila y
col.)
Son tratados aproximadamente
20 pacientes por año con SDRA
severo
Criterio principal de ingreso:
PaO2/FiO2 ≤ 100
Con una sobrevida estimada del
52%.VA-ECMO
32. Soporte vital extracorpóreo para la falla respiratoria en
adultos
Extracorporeal Life Support Organization
(Julio 2004, registro ELSO)
33. ECLS/ECMO - Randomised
Controlled Trials
Sólo dos enzayos controlados y randomizados han sido reportados
Ambos en Estados Unidos
Diferentes aproximaciones
No han sido combinados como un meta-análisis formal
34. • Adult patients (18-65 years)
• Severe, but potentially reversible
respiratory failure:
•Murray score >3.0, or
• uncompensated hypercapnoea with
a pH <7.20.
• The Murray score using all 4
parameters
• The Murray score of 3.0 is a
MINIMUM entry criterion
• Duration of high pressure and/or
high FIO2 ventilation < 7 days
• no intra-cranial bleeding
• no contra-indication to
heparinisation
35. Conventional Management
Plateau pressure <30 cm H2O
(or if plateau pressure is not
measured the peak inspiratory
pressure).
This will usually mean a
tidal volume of 4-8ml/kg body
weight as defined in the low tidal
volume ventilation strategy
according to the ARDS Network
group
36. Veno-venous ECMO via percutaneous cannulation
Blood is drained from the right atrium through a cannula introduced via
the right jugular or femoral veins, and is returned via the contra-lateral
femoral vein.
Circuits are designed to allow full support of gas exchange i.e. blood
flow of 120 ml/kg/min.
Medos Hi-Lite 7000LT poly-methyl pentene lungs with heat exchangers
are arranged in parallel with counter current gas flow
100% oxygen is used as the sweep gas.
Stockert (Sorin Biomedical) roller pumps with bladder box servo control
or venous pressure servo-regulation are used. Blood raceway tubing is
Tygon S-65-HL (Norton Performance Plastics).
Normothermia is maintained.
37. Ventilator settings are gradually reduced to allow lung rest
Peak inspiratory pressure 20 cm H2O
PEEP 10 cm H2O
Rrate 10 breaths per minute
FIO2 30%.
Anticoagulation is maintained with heparin
Patients are fed enterally or parenterally
Invasive procedures are avoided to reduce the risk of haemorrhage
Patients are diuresed to dry weight.
Haemoglobin concentrations are maintained at 14g/dl, and platelet counts
are kept >100,000 ml.
Patients are weaned from ECMO and decannulated when chest X-ray
appearance and lung compliance have improved, and adequate gas
exchange without excessive ventilation (peak pressure less than 30 cmH2O,
and FIO2 less than 60%
38. ECLS - ARF
La aplicación de ECLS para el
tratamiento del fallo respiratorio en
adultos creció rápidamente hasta 1996
ha permanecido casi constante en
aproximadamente 100 casos por año a
partir de esta fecha en los centros de
EE.UU.
La sobrevida total ha permanecido
relativamente estable en
aproximadamente 50%, pero es
variable y depende del diagnóstico
La mejor evolución parece estar
relacionada con la neumonía viral, la
neumonía por aspiración y la falla
respiratoria no imputable a SDRA
39. Complicaciones
En los estudios realizados en Europa la sobrevida
global fue del 53%, variando entre el 29 y el 70%,
según los centros.
Se admite que uno de los factores más importantes en la
determinación de los resultados es la curva de
aprendizaje del equipo tratante. Disminución de la
mortalidad con el paso del tiempo.
La complicación más importante de la técnica de
soporte extracorpóreo es la hemorragia.
40. Esta es más significativa cuando el paciente requiere
maniobras quirúrgicas tales como la colocación de tubos de
tórax o procedimientos más invasivos. En muchos casos
puede hacer necesaria la interrupción del tratamiento.
Gattinoni refiere que en 1986 los pacientes tratados en su
servicio requerían un promedio de 1,8 L de sangre por día,
mientras que a partir de la introducción de la canulación
percutánea, los requerimientos disminuyeron dramáticamente
a 200-300 ml/día.
En el registro ELSO, las complicaciones más frecuentes son
la hemorragia en el sitio quirúrgico y en el sitio de
implantación de la cánula, la hemólisis, la hemorragia
gastrointestinal y en casos aislados convulsiones
Complicaciones
43. Evolution of the Concept of
Extracorporeal CO2 Removal
Luciano Gattinoni worked with Kolobow at the National
Institutes of Health, hypotheses: The purpose of ventilation
is to excrete CO2; oxygenation can be achieved by inflation and
airway oxygenation alone. Progressive lung injury in adult
respiratory distress syndrome is caused in part by ventilator-
induced high pressure injury of the most normal alveoli. When
functional residual capacity is severely decreased, the
remaining alveoli can be overinflated if high tidal volumes are
used, leading quickly to alveolar injury and fibrosis.
An extracorporeal support system should eliminate the need
for high airway pressure and high FiO2, although this was not
always done in the NIH-sponsored ECMO study.
44. If the emphasis is on CO2removal to eliminate the need for high
pressure ventilation, this could be accomplished with
venovenous access, using relatively low flow and large
membrane-oxygenator surface area. This system would allow for
normal pulmonary blood flow, even if the lung is severely
injured with large amounts of transpulmonary shunting. The
venoarterial bypass used in the NIH ECMO study caused
decreased pulmonary blood flow which might have contributed
to microthrombosis or inhibition of lung healing.
Gattinoni and his colleagues used these principles in venovenous
extracorporeal gas exchange in a variety of adult patients selected
by the same criteria used for the NIH ECMO study. In 1986 they
reported 21 survivors in 43 patients (49 percent).
Evolution of the Concept of
Extracorporeal CO2 Removal
45. Experiencia con ECCO2R
La técnica ECCO2R ha sido utilizada ampliamente en el tratamiento de
pacientes con SDRA en Europa.
Esta técnica disminuye la ventilación alveolar, permitiendo reducir la
ventilación mecánica y con ello la injuria producida por el ventilador.
Aproximadamente el 30% del volumen minuto cardíaco es derivado al
circuito extracorpóreo.
La frecuencia respiratoria puede reducirse a dos a cuatro respiraciones por
minuto, la presión pico en la vía aérea se limita a 35 cm H2O.
El propósito de esta respiración de baja frecuencia no es remover CO2 sino
adicionar oxígeno para prevenir las atelectasias.
La oxigenación se obtiene insuflando oxígeno (2-4 l/min.) a través de un
catéter intratraqueal.
48. OXIGENADOR INTRAVENOSO EN
LA VENA CAVA (IVOX)
El IVOX es un dispositivo consistente en una gran
cantidad de fibras huecas semipermeables agrupadas
en un cilindro de pequeño diámetro, que permite su
inserción por vía venosa.
Una vez que el catéter se encuentra en la vena cava
inferior, las fibras son expuestas a la sangre venosa.
La sangre fluye alrededor de las fibras mientras se
adiciona oxígeno al interior de las mismas a presión
subatmosférica.
De esta manera, se produce el intercambio gaseoso
entre la sangre venosa y el gas que transcurre por la
membrana IVOX.
La sangre venosa se oxigena parcialmente, y se
remueven pequeñas cantidades de CO2.
Los dispositivos corrientes pueden asumir hasta el
30% del intercambio gaseoso total en un adulto con
insuficiencia respiratoria.
49. OXIGENADOR INTRAVENOSO EN
LA VENA CAVA (IVOX)
La performance del IVOX se puede cuantificar midiendo los
flujos de CO2 y O2 a través del dispositivo. Una segunda
medida de la eficacia es observar la disminución en la
saturación de la sangre venosa mixta cuando el flujo de gas a
través del IVOX se suspende.
Si bien se obtiene cierta protección contra la trombosis por la
heparina que se encuentra en el dispositivo, siempre se requiere
anticoagulación total para su aplicación.
La inserción del IVOX requiere un acceso quirúrgico, con
control radiológico durante la inserción para lograr una
adecuada localización dentro de la vena cava.
El tiempo mayor de empleo del IVOX en humanos ha sido de
18 días.
La capacidad de intercambio limitada del dispositivo, así como
el requerimiento de un implante quirúrgico y anticoagulación
sistémica, restringen su utilidad clínica
52. Artificial lungs: a new inspiration
Perfusion, Vol. 17, No. 4, 253-268 (2002)
Joseph B Zwischenberger , Scott K Alpard . Division of Cardiothoracic
Surgery, University of Texas Medical Branch, Galveston, Texas, USA
53. Artificial lungs: a new inspiration
An estimated 16 million Americans are afflictedwith
some degree of chronic obstructivepulmonary
disease (COPD), accounting for 100,000 deaths per
year. The only current treatment for chronic
irreversible pulmonary failure is lung
transplantation.
Since the widespread success of single and double
lung transplantation in the early 1990s, demand for
donor lungs has steadily outgrown the supply.Unlike
dialysis, which functions as a bridge to renal
transplantation, or a ventricular assist device(VAD),
which serves as a bridge to cardiactransplantation,
no suitable bridge to lung transplantationexists.
The current methods for supportingpatients with
lung disease, however, are not adequate or efficient
enough to act as a bridge to transplantation.
54. Artificial lungs: a new inspiration
Although occasionally successful as a bridgeto
transplant, ECMO requires multiple
transfusionsand is complex, labor-intensive,
time-limited, costly, non-ambulatory and prone
to infection.
Intravenacavaldevices, such as the intravascular
oxygenator(IVOX) and the intravenous
membrane oxygenator (IMO), are surface area
limited and currently provideinadequate gas
exchange to function as abridge-to-recovery or
transplant.
A successful artificial lungcould realize a
substantial clinical impactas a bridge to lung
transplantation, a supportdevice immediately
post-lung transplant, and as rescue and//or
supplement to mechanical ventilation duringthe
treatment of severe respiratory failure.
57. Extracorporeal LifeExtracorporeal Life
Suport (ECLS) for AdultSuport (ECLS) for Adult
Respiratory FailureRespiratory Failure
Dr. Alberto Díaz SeminarioDr. Alberto Díaz Seminario
Médico IntensivistaMédico Intensivista
UCI 2° C – Hospital Nacional EdgardoUCI 2° C – Hospital Nacional Edgardo
Rebagliati – ESSALUDRebagliati – ESSALUD
alberto06ds@yahoo.esalberto06ds@yahoo.es