SlideShare une entreprise Scribd logo
1  sur  8
Télécharger pour lire hors ligne
TYPICAL APPLICATIONS
• CRT Monitors
• X-Ray Machines
• Service Columns
• Microscopes
• Surgical Lighting
• Gas Columns
• Injector Systems
System strength, integrity and
Medical Equipment Support Systems



flexibility
                          Unistrut Corporation       demands of the most advanced medical
  PROVIDING                 has been involved in     equipment. With its inherent strength and
  A WORLD                   the engineering,         versatility, the Unistrut system adapts easily
                             design and installa-    to a wide range of environments and design
  OF SUPPORT                 tion of medical         parameters. Dur-
                           equipment support         ing installation,
                         systems for over five       built-in adjustment
                      decades. Our proven            capabilities allow
  systems support X-ray equipment, surgical          the system to be
  lighting, service columns, microsurgery units,     fine-tuned to
  as well as other specialized medical equip-        precisely match
  ment in healthcare facilities worldwide.           site conditions.
     Unistrut support extends well beyond               With manufactur-
  quality products to include in-depth plan-         ing plants on three
  ning, engineering, computer-aided design,          continents and
  fabrication, distribution and installation…        more than a hun-
  a full range of services only Unistrut can         dred authorized
  provide.                                           service centers, we
     Our expertise is built on a solid foundation.   can provide the
  Since 1935, Unistrut has been helping con-         resources and
  struction and design professionals build a         expertise to stay
  better world. Specifiers worldwide choose          with you from
  Unistrut metal framing and related Unistrut        conception to job
  systems for an infinite variety of structural      completion.
  and secondary-support applications.                Whether you’re
     You can count on Unistrut quality from          planning a new
  point of manufacture all the way through           wing, upgrading an
  project installation. The result is reliable,      existing facility, or
  consistent performance wherever Unistrut           coordinating a
  medical support systems are used. That’s           multi-location
  why we can issue an identification tag             construction
  backed by a full two-year limited war-             program, Unistrut
  ranty that assures the high quality of             professionals can
  your medical support system.                       help you meet
     Unlike other support materials, our             virtually every equipment-support need with
  system features components designed                proven, dependable, flexible solutions.
  specifically to meet the performance
Complete-system support for
Medical Equipment Support Systems



your equipment
  INFINITE                      Unistrut Medical
                                Support Systems
  ADJUSTABILITY                 allow both basic
  and micro adjustments, so installations can
  be quickly and easily adapted to specific site
  conditions. Changes, slight adjustments and
  precise “fit” are easy to achieve, simplifying
  both initial installation and future updates.



  VERSATILITY                   The Unistrut
                                system is strong
  WITH                          from top to
  AESTHETIC                     bottom providing
                               dependable and
  APPEAL                       precise support
  for all your medical equipment needs.
     For instance, the unique Telespar® vertical
  support combines the strength of square
  tubing with simple adjustability. The Unistrut
  “K” channel, with its vertical back-to-back
  design, reduces the load at weld points.
  Together, these components provide supe-
  rior strength with maximum adjustability—
  primary requirements for proper operation
  of today’s precision medical equipment.
     Ceiling tiles are installed directly on the
  “K” channel flange, flush with the bottom
  channel opening. This creates a clean,
  unobtrusive look consistent with equipment
  and room aesthetics.


  From basic X-ray machines to integrated multi-
  unit systems, Unistrut medical equipment                              Designed-in
                                                                        Designed-in
  support systems are the proven way to meet
  today’s demanding equipment support
  requirements.
                                                                        strength and
                                                                        strength and
                                                                        versatility
                                                                        versatility


                   Optional ceiling tile flange shown
Typical Room Layouts
                                                                                                                                      Prescribed by
                                                                                                                                        X-Ray Mfr.
TWO RAIL SYSTEM (In-Line)

Can be used for supporting any overhead
X-ray machine using two rails spaced




                                                                  Rail Length Determined by Architect




                                                                                                                                                 RAIL
                                                                                                                               RAIL
between 3' and 6' apart.




                                                                                                                        Prescribed by X-Ray Mfr.

THREE RAIL SYSTEM (In-Line)

Can be used for supporting any overhead
                                                                                                        CABLE TAKE-UP




X-ray machine using three rails.
                                          Rail Length Determined by Architect




                                                                                                                             RAIL




                                                                                                                                                 RAIL
Medical Equipment Support Systems

                                                                                                  Variable
UNIVERSAL GRID (Transverse)

Can be used for supporting any overhead
X-ray machine with any number of rails
because of its unique adjustability feature.




                                                                                           RAIL




                                                                                                             RAIL
                                                                        Preferred O.C.
                                                                         26'' to 265⁄8''
                                                             Variable
RIGID MOUNT

Can be used for rigid-mounting of various
medical apparatus such as medical
lights or rigid-mounted pendent
type microscopes.




ISOLATED MOUNT

Features vibration-absorbing isolators and is
a perfect choice for supporting pendent
mounted microscopes.
General Specifications
I. GENERAL                                         2. Manufacturer’s Brochure: Brochure shall          4. Seismic Bracing: Medical system shall be
A. SCOPE                                              show materials, strengths, finishes and             adequately braced to meet all code
1. Contractor shall provide and install a             sizes. Sufficient engineering information           requirements.
   medical support system(s) as indicated on          shall be provided to permit stress calcula-      5. Loading:The support structure shall be
   the reflected ceiling plans, in rooms              tions. Materials listed should conform to           designed to support a concentrated load of
   ____________________________________               the appropriate specifications from ASTM,           ______ lbs. , at any single point along the
   located at ___________________________.            AISI, AISC, and/or AWS.                             exposed rails. The concentrated load shall
   System shall be a “Universal Grid” type         3. Calculations (optional):The medical                 be the maximum that will be encountered
   when possible, with rails extending wall to        support system shall lend itself to a rational      by positioning the equipment at the
   wall, perpendicular to the path of travel of       structural analysis with section properties         extremities of its travel (maximal load
   the equipment. Rail shall be on centers as         of framing members demonstrated by                  configuration).
   required by equipment manufacturer and             calculations. Structural calculations and        6. Safety Factor:The system shall be designed
   allow continuous attachment along any              drawings shall be furnished with a stamp            with a minimum safety factor of 21⁄2 based
   point on the rail. System shall be true,           by a licensed engineer complying with all           on ultimate strength under static loading
   plumb and level to the tolerances indi-            applicable codes and regulatory require-            conditions.
   cated, with no more than 1/720th of the            ments.
   span maximum deflection in either plane,                                                            III. INSTALLATION
   when maximum loading conditions are             II. MATERIAL AND DESIGN                             A. FIELD MEASUREMENTS
   applied due to equipment operation.             A. MATERIAL                                           The contractor shall make field measure-
                                                   1. Materials used shall conform to the                ments to assure that the medical support
2. Work of others sections                            following ASTM specifications:                     can be installed according to plans, and
   a) Ceiling                                         ASTM 653SQ33,ASTM A570 Grade 33,                   without interference with structural
   b) Painting                                        ASTM A575, ASTM 675 Grade 50, SAE J429             framing, mechanical systems, plumbing or
   c) Electrical                                      Grade 2.                                           other obstructions. Any interferences shall
   d) _____________                                2. All materials shall be protected from              be reported to the architect.
                                                      corrosion with a factory applied finish.
B. QUALITY ASSURANCE                               3. All materials shall be stamped and               B. SEQUENCING
1. Material and installation shall be provided        identifiable by manufacturer and part              The contractor shall assure that the
   by a qualified vendor, with at least five (5)      number (where appropriate). Materials              support system is installed in a timely and
   years experience in the manufacture and            that appear damaged, distressed, unidentifi-       practical sequence, ahead of any extensive
   installation of adjustable metal framing           able or rusted shall not be used and will          electrical, mechanical or HVAC work in the
   supports. Vendor shall demonstrate                 not be accepted.                                   area, and prior to any ceiling framing or
   experience of projects of similar scope and                                                           room finishes.
   size, and shall maintain a continuing quality   B. DESIGN
   assurance program for both its material and     1. Support Structure:The support members at         C. PAINTING
   installation crews.                                the ceiling plane shall be located as              All exposed members shall be painted by
2. Vendor shall provide the single source             indicated on the drawings. They shall              the painting contractor with paint
   responsibility for materials and workman-          consist of Unistrut “K” series x-ray channel.      compatible to the support systems.
   ship, and shall provide a warranty period of       The spacing shall allow installation of
   one (1) year from date of acceptance by            standard modular 24" ceiling fixtures and        D. MODIFICATIONS
   architect/owner.                                   equipment. It shall be possible to attach          Any changes or modifications from
3. Acceptable Vendors: Unistrut Corporation           the medical equipment at any point on the          approved shop drawings shall require
   and/or its authorized representative.              support system.                                    approval from the architect and engineer,
                                                   2. Ceiling Anchorage:Whenever possible,               and shall be noted on the final drawings.
C. SUBMITTAL                                          attachment to ceiling structure above shall
1. Shop Drawings: Successful vendor shall             be done by means of imbedded concrete            E. LIABILITY
   submit shop drawings showing the                   inserts, through bolts, or by direct               Installing contractor shall be able to
   complete system, including plans, sections         attachment to the structural framing of the        furnish coverage liability insurance with
   and details of the system. Plans shall show        building.                                          limitation of no less than one million
   all manufactured parts, by catalog numbers,     3. Vertical supports: The exposed “K” series          dollars. Material, design and installations
   all fabricated parts, and all fasteners and        rails and the ceiling anchorage shall be           shall be furnished by a single source to
   hardware.                                          connected by a series of 12 Gauge                  minimize total liability.
                                                      Telespar® vertical supports as indicated on
                                                      the drawings. Vertical supports shall
                                                      provide for both basic and micro vertical
                                                      adjustment.




  Unistrut Corporation • 1140 West Thorndale Ave. • Itasca, IL 60143 • (800) 468-9510 FAX (630) 773-4214

   UMMS 300      Printed in USA 5/99    © Unistrut Corporation

Contenu connexe

Similaire à MEDICAL EQUIPMENT SUPPORT SYSTEMS

Anritsu Linecard
Anritsu LinecardAnritsu Linecard
Anritsu LinecardMike Bruhns
 
MAST Mobile Autonomous Surveillance Trailer: 24/7 Day Night Imaging Off Grid ...
MAST Mobile Autonomous Surveillance Trailer: 24/7 Day Night Imaging Off Grid ...MAST Mobile Autonomous Surveillance Trailer: 24/7 Day Night Imaging Off Grid ...
MAST Mobile Autonomous Surveillance Trailer: 24/7 Day Night Imaging Off Grid ...Tim Troxel
 
Linear Accelerator- Commercial Specification & Comparison
Linear Accelerator- Commercial Specification & ComparisonLinear Accelerator- Commercial Specification & Comparison
Linear Accelerator- Commercial Specification & ComparisonArindham Debbarma
 
Suspended Platform Systems (EN)
Suspended Platform Systems (EN)Suspended Platform Systems (EN)
Suspended Platform Systems (EN)XSPlatforms
 
Extricom Corporate Brochure 2009
Extricom Corporate Brochure 2009Extricom Corporate Brochure 2009
Extricom Corporate Brochure 2009MathewEdwards
 
Inclinometer sensors
Inclinometer sensorsInclinometer sensors
Inclinometer sensorsDavid M.Blass
 
POSITAL Product Catalog
POSITAL Product CatalogPOSITAL Product Catalog
POSITAL Product Catalogposital
 
Vendor Highlights from the AHRA 2014 Conference l MD Buyline
Vendor Highlights from the AHRA 2014 Conference l MD BuylineVendor Highlights from the AHRA 2014 Conference l MD Buyline
Vendor Highlights from the AHRA 2014 Conference l MD BuylineMD Buyline
 
Setting a new radiotherapy facility-steps involved
Setting a new radiotherapy facility-steps involvedSetting a new radiotherapy facility-steps involved
Setting a new radiotherapy facility-steps involvedAnil Gupta
 
Kensington Robot Repairing & Automation Solutions
Kensington Robot Repairing & Automation SolutionsKensington Robot Repairing & Automation Solutions
Kensington Robot Repairing & Automation Solutionskensington labs
 
Catalogo Examion Produvet
Catalogo Examion ProduvetCatalogo Examion Produvet
Catalogo Examion Produvetproduvet
 
LabVIEW Based Monitoring the Building in wireless communication
LabVIEW Based Monitoring the Building in wireless communicationLabVIEW Based Monitoring the Building in wireless communication
LabVIEW Based Monitoring the Building in wireless communicationSathish Kumar
 
CorrosionRADAR applications
CorrosionRADAR applicationsCorrosionRADAR applications
CorrosionRADAR applicationsPrafull Sharma
 
Application of Automation in different sectors
Application of Automation in different sectorsApplication of Automation in different sectors
Application of Automation in different sectorsGouthamarajan NT
 

Similaire à MEDICAL EQUIPMENT SUPPORT SYSTEMS (20)

Anritsu Linecard
Anritsu LinecardAnritsu Linecard
Anritsu Linecard
 
Catalogo rx digital
Catalogo rx digitalCatalogo rx digital
Catalogo rx digital
 
Posital catalog
Posital catalogPosital catalog
Posital catalog
 
MAST Mobile Autonomous Surveillance Trailer: 24/7 Day Night Imaging Off Grid ...
MAST Mobile Autonomous Surveillance Trailer: 24/7 Day Night Imaging Off Grid ...MAST Mobile Autonomous Surveillance Trailer: 24/7 Day Night Imaging Off Grid ...
MAST Mobile Autonomous Surveillance Trailer: 24/7 Day Night Imaging Off Grid ...
 
Linear Accelerator- Commercial Specification & Comparison
Linear Accelerator- Commercial Specification & ComparisonLinear Accelerator- Commercial Specification & Comparison
Linear Accelerator- Commercial Specification & Comparison
 
Suspended Platform Systems (EN)
Suspended Platform Systems (EN)Suspended Platform Systems (EN)
Suspended Platform Systems (EN)
 
UNITILE, DATA CENTER
UNITILE, DATA CENTER UNITILE, DATA CENTER
UNITILE, DATA CENTER
 
Extricom Corporate Brochure 2009
Extricom Corporate Brochure 2009Extricom Corporate Brochure 2009
Extricom Corporate Brochure 2009
 
Inclinometer sensors
Inclinometer sensorsInclinometer sensors
Inclinometer sensors
 
POSITAL Product Catalog
POSITAL Product CatalogPOSITAL Product Catalog
POSITAL Product Catalog
 
Vendor Highlights from the AHRA 2014 Conference l MD Buyline
Vendor Highlights from the AHRA 2014 Conference l MD BuylineVendor Highlights from the AHRA 2014 Conference l MD Buyline
Vendor Highlights from the AHRA 2014 Conference l MD Buyline
 
Setting a new radiotherapy facility-steps involved
Setting a new radiotherapy facility-steps involvedSetting a new radiotherapy facility-steps involved
Setting a new radiotherapy facility-steps involved
 
Kensington Robot Repairing & Automation Solutions
Kensington Robot Repairing & Automation SolutionsKensington Robot Repairing & Automation Solutions
Kensington Robot Repairing & Automation Solutions
 
Catalogo Examion Produvet
Catalogo Examion ProduvetCatalogo Examion Produvet
Catalogo Examion Produvet
 
NX-ERA XPRESS THE COMPACT MICRO PLC..pdf
NX-ERA XPRESS THE COMPACT MICRO PLC..pdfNX-ERA XPRESS THE COMPACT MICRO PLC..pdf
NX-ERA XPRESS THE COMPACT MICRO PLC..pdf
 
LabVIEW Based Monitoring the Building in wireless communication
LabVIEW Based Monitoring the Building in wireless communicationLabVIEW Based Monitoring the Building in wireless communication
LabVIEW Based Monitoring the Building in wireless communication
 
CorrosionRADAR applications
CorrosionRADAR applicationsCorrosionRADAR applications
CorrosionRADAR applications
 
LinkedPro (US)
LinkedPro (US)LinkedPro (US)
LinkedPro (US)
 
Application of Automation in different sectors
Application of Automation in different sectorsApplication of Automation in different sectors
Application of Automation in different sectors
 
BELT TESTING MACHINE WITH MESSUNG'S NX-ERA XPRESS PLC SERIES.pdf
BELT TESTING MACHINE WITH MESSUNG'S NX-ERA XPRESS PLC SERIES.pdfBELT TESTING MACHINE WITH MESSUNG'S NX-ERA XPRESS PLC SERIES.pdf
BELT TESTING MACHINE WITH MESSUNG'S NX-ERA XPRESS PLC SERIES.pdf
 

Plus de unistrutbc (10)

Zrccat2
Zrccat2Zrccat2
Zrccat2
 
Mfsc4
Mfsc4Mfsc4
Mfsc4
 
Tcat1
Tcat1Tcat1
Tcat1
 
Zrccat1
Zrccat1Zrccat1
Zrccat1
 
Tcat2
Tcat2Tcat2
Tcat2
 
Mfsc7
Mfsc7Mfsc7
Mfsc7
 
Mfsc6
Mfsc6Mfsc6
Mfsc6
 
Mfsc8
Mfsc8Mfsc8
Mfsc8
 
Mfsc2
Mfsc2Mfsc2
Mfsc2
 
Mfsc1
Mfsc1Mfsc1
Mfsc1
 

MEDICAL EQUIPMENT SUPPORT SYSTEMS

  • 1. TYPICAL APPLICATIONS • CRT Monitors • X-Ray Machines • Service Columns • Microscopes • Surgical Lighting • Gas Columns • Injector Systems
  • 3. Medical Equipment Support Systems flexibility Unistrut Corporation demands of the most advanced medical PROVIDING has been involved in equipment. With its inherent strength and A WORLD the engineering, versatility, the Unistrut system adapts easily design and installa- to a wide range of environments and design OF SUPPORT tion of medical parameters. Dur- equipment support ing installation, systems for over five built-in adjustment decades. Our proven capabilities allow systems support X-ray equipment, surgical the system to be lighting, service columns, microsurgery units, fine-tuned to as well as other specialized medical equip- precisely match ment in healthcare facilities worldwide. site conditions. Unistrut support extends well beyond With manufactur- quality products to include in-depth plan- ing plants on three ning, engineering, computer-aided design, continents and fabrication, distribution and installation… more than a hun- a full range of services only Unistrut can dred authorized provide. service centers, we Our expertise is built on a solid foundation. can provide the Since 1935, Unistrut has been helping con- resources and struction and design professionals build a expertise to stay better world. Specifiers worldwide choose with you from Unistrut metal framing and related Unistrut conception to job systems for an infinite variety of structural completion. and secondary-support applications. Whether you’re You can count on Unistrut quality from planning a new point of manufacture all the way through wing, upgrading an project installation. The result is reliable, existing facility, or consistent performance wherever Unistrut coordinating a medical support systems are used. That’s multi-location why we can issue an identification tag construction backed by a full two-year limited war- program, Unistrut ranty that assures the high quality of professionals can your medical support system. help you meet Unlike other support materials, our virtually every equipment-support need with system features components designed proven, dependable, flexible solutions. specifically to meet the performance
  • 5. Medical Equipment Support Systems your equipment INFINITE Unistrut Medical Support Systems ADJUSTABILITY allow both basic and micro adjustments, so installations can be quickly and easily adapted to specific site conditions. Changes, slight adjustments and precise “fit” are easy to achieve, simplifying both initial installation and future updates. VERSATILITY The Unistrut system is strong WITH from top to AESTHETIC bottom providing dependable and APPEAL precise support for all your medical equipment needs. For instance, the unique Telespar® vertical support combines the strength of square tubing with simple adjustability. The Unistrut “K” channel, with its vertical back-to-back design, reduces the load at weld points. Together, these components provide supe- rior strength with maximum adjustability— primary requirements for proper operation of today’s precision medical equipment. Ceiling tiles are installed directly on the “K” channel flange, flush with the bottom channel opening. This creates a clean, unobtrusive look consistent with equipment and room aesthetics. From basic X-ray machines to integrated multi- unit systems, Unistrut medical equipment Designed-in Designed-in support systems are the proven way to meet today’s demanding equipment support requirements. strength and strength and versatility versatility Optional ceiling tile flange shown
  • 6. Typical Room Layouts Prescribed by X-Ray Mfr. TWO RAIL SYSTEM (In-Line) Can be used for supporting any overhead X-ray machine using two rails spaced Rail Length Determined by Architect RAIL RAIL between 3' and 6' apart. Prescribed by X-Ray Mfr. THREE RAIL SYSTEM (In-Line) Can be used for supporting any overhead CABLE TAKE-UP X-ray machine using three rails. Rail Length Determined by Architect RAIL RAIL
  • 7. Medical Equipment Support Systems Variable UNIVERSAL GRID (Transverse) Can be used for supporting any overhead X-ray machine with any number of rails because of its unique adjustability feature. RAIL RAIL Preferred O.C. 26'' to 265⁄8'' Variable RIGID MOUNT Can be used for rigid-mounting of various medical apparatus such as medical lights or rigid-mounted pendent type microscopes. ISOLATED MOUNT Features vibration-absorbing isolators and is a perfect choice for supporting pendent mounted microscopes.
  • 8. General Specifications I. GENERAL 2. Manufacturer’s Brochure: Brochure shall 4. Seismic Bracing: Medical system shall be A. SCOPE show materials, strengths, finishes and adequately braced to meet all code 1. Contractor shall provide and install a sizes. Sufficient engineering information requirements. medical support system(s) as indicated on shall be provided to permit stress calcula- 5. Loading:The support structure shall be the reflected ceiling plans, in rooms tions. Materials listed should conform to designed to support a concentrated load of ____________________________________ the appropriate specifications from ASTM, ______ lbs. , at any single point along the located at ___________________________. AISI, AISC, and/or AWS. exposed rails. The concentrated load shall System shall be a “Universal Grid” type 3. Calculations (optional):The medical be the maximum that will be encountered when possible, with rails extending wall to support system shall lend itself to a rational by positioning the equipment at the wall, perpendicular to the path of travel of structural analysis with section properties extremities of its travel (maximal load the equipment. Rail shall be on centers as of framing members demonstrated by configuration). required by equipment manufacturer and calculations. Structural calculations and 6. Safety Factor:The system shall be designed allow continuous attachment along any drawings shall be furnished with a stamp with a minimum safety factor of 21⁄2 based point on the rail. System shall be true, by a licensed engineer complying with all on ultimate strength under static loading plumb and level to the tolerances indi- applicable codes and regulatory require- conditions. cated, with no more than 1/720th of the ments. span maximum deflection in either plane, III. INSTALLATION when maximum loading conditions are II. MATERIAL AND DESIGN A. FIELD MEASUREMENTS applied due to equipment operation. A. MATERIAL The contractor shall make field measure- 1. Materials used shall conform to the ments to assure that the medical support 2. Work of others sections following ASTM specifications: can be installed according to plans, and a) Ceiling ASTM 653SQ33,ASTM A570 Grade 33, without interference with structural b) Painting ASTM A575, ASTM 675 Grade 50, SAE J429 framing, mechanical systems, plumbing or c) Electrical Grade 2. other obstructions. Any interferences shall d) _____________ 2. All materials shall be protected from be reported to the architect. corrosion with a factory applied finish. B. QUALITY ASSURANCE 3. All materials shall be stamped and B. SEQUENCING 1. Material and installation shall be provided identifiable by manufacturer and part The contractor shall assure that the by a qualified vendor, with at least five (5) number (where appropriate). Materials support system is installed in a timely and years experience in the manufacture and that appear damaged, distressed, unidentifi- practical sequence, ahead of any extensive installation of adjustable metal framing able or rusted shall not be used and will electrical, mechanical or HVAC work in the supports. Vendor shall demonstrate not be accepted. area, and prior to any ceiling framing or experience of projects of similar scope and room finishes. size, and shall maintain a continuing quality B. DESIGN assurance program for both its material and 1. Support Structure:The support members at C. PAINTING installation crews. the ceiling plane shall be located as All exposed members shall be painted by 2. Vendor shall provide the single source indicated on the drawings. They shall the painting contractor with paint responsibility for materials and workman- consist of Unistrut “K” series x-ray channel. compatible to the support systems. ship, and shall provide a warranty period of The spacing shall allow installation of one (1) year from date of acceptance by standard modular 24" ceiling fixtures and D. MODIFICATIONS architect/owner. equipment. It shall be possible to attach Any changes or modifications from 3. Acceptable Vendors: Unistrut Corporation the medical equipment at any point on the approved shop drawings shall require and/or its authorized representative. support system. approval from the architect and engineer, 2. Ceiling Anchorage:Whenever possible, and shall be noted on the final drawings. C. SUBMITTAL attachment to ceiling structure above shall 1. Shop Drawings: Successful vendor shall be done by means of imbedded concrete E. LIABILITY submit shop drawings showing the inserts, through bolts, or by direct Installing contractor shall be able to complete system, including plans, sections attachment to the structural framing of the furnish coverage liability insurance with and details of the system. Plans shall show building. limitation of no less than one million all manufactured parts, by catalog numbers, 3. Vertical supports: The exposed “K” series dollars. Material, design and installations all fabricated parts, and all fasteners and rails and the ceiling anchorage shall be shall be furnished by a single source to hardware. connected by a series of 12 Gauge minimize total liability. Telespar® vertical supports as indicated on the drawings. Vertical supports shall provide for both basic and micro vertical adjustment. Unistrut Corporation • 1140 West Thorndale Ave. • Itasca, IL 60143 • (800) 468-9510 FAX (630) 773-4214 UMMS 300 Printed in USA 5/99 © Unistrut Corporation