I’m Walt Boyes, and if you are like most automation
professionals, you don’t do flow measurement design daily
or even weekly. So some of the basics may be new to you…
especially in the area of open channel flow.

1
The picture you see is of a “Nilometer.” It is one of many
devices built since 3000 BC to measure the height (and
calculate the flow) of the Nile river in Egypt. It is very likely
the first flowmeter, and it measures open channel flow.
For the next few minutes, we are going to look at the theory
and practice of open channel flow, and by the end of our
time together, you will be able to “Flow Like an Egyptian.”

2
There are two basic ways to measure flow in an open
channel or conduit.
The first is to use one of the formulas like Manning’s
Equation, which have been developed for open channel flow
in ditches, rivers, and canals. You must calculate a wetted
perimeter, and know the slope of the conduit, and guess at
the roughness of the bottom of the conduit, or pipe.
The second method is to measure the height of the flowing
stream at a known distance behind (upstream) of a
predictable hydraulic jump, such as a flume or weir.

3
In 1889, Irish engineer Robert Manning produced an
equation for calculating flow in open conduits from the level
in the channel.
Manning's equation works best in man-made conduits because the hydraulic
radius, slope and coefficient of friction can be better known or estimated. It will
work in any open channel, but the error expands as these terms are less well
known. Manning's equation, and its successors, are often used for calculating the
flow in sewers and in man-made irrigation channels.
Although tables of Manning's "n" are common, it is nearly impossible to
accurately calculate "n," so it is almost always an educated guess, based on the
engineer's experience and expertise. A small change in "n" can result in a large
change in "V" and thus a large change in "Q."

4
For real accuracy, the use of a primary device is required. These are restrictive
devices placed in the flow stream that raise the height of the water behind the
restriction to a predictable level based on volumetric flow. Typically, these
devices are flumes and weirs. Weirs have been known for centuries, and were
used as primitive spillways from small earthen dams. Measurement weirs come
in several configurations: v-notch, rectangular and trapezoidal, among others.
The U. S. Department of the Interior’s Bureau of Reclamation publishes an
online version of its comprehensive "Water Measurement Manual" which details
all the various types of weirs and flumes, and how to install them and maintain
them.
In a v-notch weir, all the water flows through the weir, and the level is measured
at a known point behind (upstream) of the weir. This level forms the "H" in our
formula.
Sometimes, if very high accuracy is required at the lowest flow rates, a
compound weir can be used. This is often a rectangular weir with a sharp vnotch forming the bottom of the weir. Thus, the rectangular weir equation can be
used for high flows, and once the flow reduces to below the zero point of the
rectangular weir, the v-notch equation is used. Many open channel flow
transmitters have the ability to switch equations like this.

5
Note that I said flow transmitter not flow meter. That’s because the primary
device is itself the flow meter. All the transmitter does is to automate the staff
gauge. As with the Nilometer, a primary device can measure flow using the
calibrated Mark 1 eyeball. What the various types of flow transmitters do is to
make it unnecessary for somebody to stand there and eyeball the primary device.

6
Flumes have a constriction in the flow, and a "hydraulic jump" that causes the
head height to be linear and repeatable. There are dozens of kinds of flumes. In
modern times, the most common are the Parshall and the Palmer-Bowlus flumes.
Parshall flumes are commonly used for flow measurement at the inlet and outlet
to wastewater treatment plants and surface water intakes for treatment plants and
power plants. Typically, a Parshall flume is supplied as a fiberglas "liner" that is
installed and then cemented in place. In this picture, the flume is cutaway so you
can clearly see the hydraulic jump.

7
Palmer-Bowlus flumes were originally developed for measurement in sewers
and other open conduits with relatively low flow. There is no constriction, as
with a Parshall flume, but there is a complex hydraulic jump that forms the point
where the height is directly proportional to flow rate, the "H" in our equation.

8
Here’s the equation for flumes and weirs. Note how critical the measurement of
H, liquid level, is. There are many tables of coefficients and examples of how to
calculate flow. Flow transmitters all have equations built into them.

9
For a flume or weir to be accurate, it must be installed properly. Most error
problems with open channel flow measurements are traceable to the accuracy of
the flume or weir, not the level measurement or the flow transmitter.
All flumes and weirs must be installed as close to perfectly level inlet-to-outlet
as possible, and side-to-side, too. Fiberglass flumes often "bow in" when
concrete is poured behind them, and this produces unexpected inaccuracies,
which may not be able to be calibrated out, except by in-situ flow testing and the
use of a strapping table in the flow transmitter.
All flumes and weirs have what is called the "submergence point" where the
level goes above the measurement range of the device. Flow may continue to be
moving in either direction during submergence, but the measurement is
meaningless during that condition.

10
11
A small compressor pumps air into a reservoir. This air is released slowly by a
needle valve into a bubble line, a length of small diameter flexible tubing. The
other end of this tube is submerged in the flow stream. Inside the flow
transmitter, the bubble line also connects to one side of a differential pressure
transducer. As air is released slowly into the bubble line by the needle valve,
pressure builds inside the line to force the air out of the line into the flow stream.
When there is enough pressure to counteract the hydrostatic pressure of the flow
stream, a bubble is forced from the end of the line. The amount of pressure
required to force the bubble from the end of the line is directly dependent on the
hydrostatic pressure of the flow stream over the end of the bubble line. The
pressure transducer inside the flow meter senses this pressure and converts it into
an electrical signal that the flow transmitter converts into level. From the
measured level detected by the bubbler the flow meter then calculates flow rate
and total flow.

12
You can still find capacitance or RF Admittance Flow Transmitters for open
channel flow, like this one. The capacitance or admittance changes with the level
on the sensor, and the level signal is then converted to flow. These sensors have
lots of issues, especially with grease or foam in wastewater or irrigation, but they
work very well in small flumes and weirs.

13
Originally a purely mechanical measurement, with a windup chart recorder, float
and tape flowmeters are still in use all over the world, mostly for stream gauging
for organizations like USGS. The movement of the float drives a cam operated
pen across the chart. Simple, effective, accurate, and doesn’t require power. The
operator winds the chart motor every week or so, when he comes to change the
chart.

14
Ultrasonic open channel flowmeters have become the workhorse of the industry.
They are non-contacting, and they are very accurate if installed correctly. Note
that the picture shows that it isn’t just a matter of sticking a sensor over a flume
or weir. For example, the plastic condolet and the flex conduit are there not to
make the mounting easy but to damp ringing of the sensor. Think of the sensor as
a drum that is struck every n times a second. It beats, then listens for the echo.
The time difference between the time the drumbeat left the sensor and the time
the return signal arrives gives the distance to the liquid height. The key to good
applications is to mount the sensor so that it is absolutely vertical, and far
enough away from the channel wall so it doesn’t get a signal back from the hard
surface. Such signals sometimes overpower the circuitry in the flow transmitter.
Wind, foam, steam and other off-gases interfere, sometimes terminally, with
ultrasonic open channel flowmeters.

15
Both guided wave and downlooking radar transmitters have been used for open
channel flow where wind or other interference makes it impossible to use
ultrasonic flow sensors.

16
Just like its ancient predecessor, the Nilometer, the staff gauge is a ruler stuck in
the flow with its end point at the arbitrary zero flow point. It is read by the
calibrated MK I Eyeball.

17
Area-velocity flow meters are based on the theory that there is a point in the flow
in an open conduit where the measured flow is equal to the average flow rate in
the fluid. These flow meters are usually used for sewer flow and sewer capacity
and surcharge studies, since the velocity sensor is designed to be bidirectional.
Sensors that have been used include differential pressure, ultrasonic and radar for
the top level, and ultrasonic (doppler type) and electromagnetic for the velocity.
Proponents of this theory say that Q=VA works with this methodology. However,
a cautionary tale. Quite a few years ago, a consulting engineer doing a flow
study for a large city in New Jersey found data from one A-V flowmeter that
indicated that Manhattan had been underwater up to the top of the Empire State
Building.

18
Area-velocity flow meters being problematic, a flow meter was designed with a
special purpose (and highly calibratable) primary device for measuring sewer
flows and surcharges. It was called the DataGator, and is still available from
Renaissance Instruments. It won an R&D100 award the year it was introduced. It
is the only third-party calibratable flow meter for use in sewers. There are four
categories of flow that the DataGator works in. For free flow, it works like a
standard flume. In submerged flow, it operates using its proprietary flume
design. In full pipe flow at transition (from submerged to pressurized) it works
like a calibrated venturi tube. And the venturi measurement continues when the
pipe is full and the measurement is fully bidirectional.

19
If you’ve followed me so far, you get a gold star…and
Continuing Education Units!

20

Contenu connexe

Tendances

Estimate coefficient of discharge for rectangular and V notches weirs
Estimate coefficient of discharge for rectangular and V notches weirsEstimate coefficient of discharge for rectangular and V notches weirs
Estimate coefficient of discharge for rectangular and V notches weirsNabeel Afzal
 
Flow Measuring Device
Flow  Measuring Device Flow  Measuring Device
Flow Measuring Device PREM BAGADE
 
notch and its types
 notch and its types notch and its types
notch and its typesUsama Pervaiz
 
Lecture 4 flow_measurements
Lecture 4 flow_measurementsLecture 4 flow_measurements
Lecture 4 flow_measurementsRaghubir Singh
 
measurement of the flow of fluid by the venturimeter and the pitot tube and ...
 measurement of the flow of fluid by the venturimeter and the pitot tube and ... measurement of the flow of fluid by the venturimeter and the pitot tube and ...
measurement of the flow of fluid by the venturimeter and the pitot tube and ...AshishBhadani4
 
fluid flow measuring instruments
fluid flow measuring instrumentsfluid flow measuring instruments
fluid flow measuring instrumentsGaurav Dave
 
Flow measurement - It contents all type of Flow Measuring devices like Orifi...
Flow measurement -  It contents all type of Flow Measuring devices like Orifi...Flow measurement -  It contents all type of Flow Measuring devices like Orifi...
Flow measurement - It contents all type of Flow Measuring devices like Orifi...Prof. S D Yadav, MGM,S JNEC AURANGABAD
 
Variable Headmeter
Variable HeadmeterVariable Headmeter
Variable HeadmeterShivang258
 

Tendances (20)

Estimate coefficient of discharge for rectangular and V notches weirs
Estimate coefficient of discharge for rectangular and V notches weirsEstimate coefficient of discharge for rectangular and V notches weirs
Estimate coefficient of discharge for rectangular and V notches weirs
 
Flow Measuring Device
Flow  Measuring Device Flow  Measuring Device
Flow Measuring Device
 
Current meter, cup type
Current meter, cup typeCurrent meter, cup type
Current meter, cup type
 
Venturimeter
VenturimeterVenturimeter
Venturimeter
 
Flow measurement
Flow measurementFlow measurement
Flow measurement
 
notch and its types
 notch and its types notch and its types
notch and its types
 
Lecture 4 flow_measurements
Lecture 4 flow_measurementsLecture 4 flow_measurements
Lecture 4 flow_measurements
 
Range of Coriolis Mass Flow Meters - Rheonik
Range of Coriolis Mass Flow Meters - RheonikRange of Coriolis Mass Flow Meters - Rheonik
Range of Coriolis Mass Flow Meters - Rheonik
 
Flow standards
Flow standards Flow standards
Flow standards
 
Flow meter
Flow meterFlow meter
Flow meter
 
measurement of the flow of fluid by the venturimeter and the pitot tube and ...
 measurement of the flow of fluid by the venturimeter and the pitot tube and ... measurement of the flow of fluid by the venturimeter and the pitot tube and ...
measurement of the flow of fluid by the venturimeter and the pitot tube and ...
 
fluid flow measuring instruments
fluid flow measuring instrumentsfluid flow measuring instruments
fluid flow measuring instruments
 
Level Measurement
Level MeasurementLevel Measurement
Level Measurement
 
Flow measurement part i
Flow measurement   part iFlow measurement   part i
Flow measurement part i
 
Flow measurement - It contents all type of Flow Measuring devices like Orifi...
Flow measurement -  It contents all type of Flow Measuring devices like Orifi...Flow measurement -  It contents all type of Flow Measuring devices like Orifi...
Flow measurement - It contents all type of Flow Measuring devices like Orifi...
 
Vortex flow Meter
Vortex flow MeterVortex flow Meter
Vortex flow Meter
 
Variable Headmeter
Variable HeadmeterVariable Headmeter
Variable Headmeter
 
various flow meter
various flow metervarious flow meter
various flow meter
 
Electromagnetic flow measurement
Electromagnetic flow measurementElectromagnetic flow measurement
Electromagnetic flow measurement
 
Flow measurement
Flow measurementFlow measurement
Flow measurement
 

En vedette (6)

Hidro
HidroHidro
Hidro
 
Open channel flow
Open channel flowOpen channel flow
Open channel flow
 
(Part ii)- open channels
(Part ii)- open channels(Part ii)- open channels
(Part ii)- open channels
 
open channel flow
open channel flowopen channel flow
open channel flow
 
Open Channel Flow
Open Channel FlowOpen Channel Flow
Open Channel Flow
 
Chap1 open channel flow
Chap1 open channel flowChap1 open channel flow
Chap1 open channel flow
 

Similaire à Flow Like an Egyptian: The Basics of Open Channel Flow

Design & analysis of laminar flow meter
Design & analysis of laminar flow meterDesign & analysis of laminar flow meter
Design & analysis of laminar flow meterAbhijit Roy
 
Water measurement
Water measurementWater measurement
Water measurementHina Bhatu
 
McCrometer V Cone Flowmeter Installation, Operations, Maintenace
McCrometer V Cone Flowmeter Installation, Operations, MaintenaceMcCrometer V Cone Flowmeter Installation, Operations, Maintenace
McCrometer V Cone Flowmeter Installation, Operations, MaintenaceFlow-Tech, Inc.
 
12 Flow measurement.ppt
12 Flow measurement.ppt12 Flow measurement.ppt
12 Flow measurement.pptMoazamAmin
 
A Presentation on Field Instrumentation .pdf
A Presentation on Field Instrumentation .pdfA Presentation on Field Instrumentation .pdf
A Presentation on Field Instrumentation .pdfEmmanuelMatutu
 
Importance and Practical application of Fluid Mechanics sessional
Importance and Practical application of  Fluid Mechanics sessionalImportance and Practical application of  Fluid Mechanics sessional
Importance and Practical application of Fluid Mechanics sessionalEmranHossainEmon1
 
unit-5-flowmeasurement.pdf
unit-5-flowmeasurement.pdfunit-5-flowmeasurement.pdf
unit-5-flowmeasurement.pdfPravinaMistry2
 
Flow measurement
Flow measurementFlow measurement
Flow measurementKarnav Rana
 
orifice meter and its application_ppt
orifice meter and its application_pptorifice meter and its application_ppt
orifice meter and its application_pptKrishna Peshivadiya
 
Flow measuring devices - It contents all type of Flow Measuring devices like ...
Flow measuring devices - It contents all type of Flow Measuring devices like ...Flow measuring devices - It contents all type of Flow Measuring devices like ...
Flow measuring devices - It contents all type of Flow Measuring devices like ...Prof. S D Yadav, MGM,S JNEC AURANGABAD
 
Flow measurement in industries
Flow measurement in industriesFlow measurement in industries
Flow measurement in industriesMohsin Mulla
 
UNIT 1 UNIFORM FLOW.pptx
UNIT 1 UNIFORM FLOW.pptxUNIT 1 UNIFORM FLOW.pptx
UNIT 1 UNIFORM FLOW.pptxreenarana28
 
UNIFORM FLOW OCF.pptx
UNIFORM FLOW OCF.pptxUNIFORM FLOW OCF.pptx
UNIFORM FLOW OCF.pptxreenarana28
 

Similaire à Flow Like an Egyptian: The Basics of Open Channel Flow (20)

Stream gauging ppt
Stream gauging pptStream gauging ppt
Stream gauging ppt
 
Design & analysis of laminar flow meter
Design & analysis of laminar flow meterDesign & analysis of laminar flow meter
Design & analysis of laminar flow meter
 
Water measurement
Water measurementWater measurement
Water measurement
 
McCrometer V Cone Flowmeter Installation, Operations, Maintenace
McCrometer V Cone Flowmeter Installation, Operations, MaintenaceMcCrometer V Cone Flowmeter Installation, Operations, Maintenace
McCrometer V Cone Flowmeter Installation, Operations, Maintenace
 
12 Flow measurement.ppt
12 Flow measurement.ppt12 Flow measurement.ppt
12 Flow measurement.ppt
 
Flow measuring devices
Flow measuring devicesFlow measuring devices
Flow measuring devices
 
CH28.PDF
CH28.PDFCH28.PDF
CH28.PDF
 
A Presentation on Field Instrumentation.
A Presentation on Field Instrumentation.A Presentation on Field Instrumentation.
A Presentation on Field Instrumentation.
 
A Presentation on Field Instrumentation .pdf
A Presentation on Field Instrumentation .pdfA Presentation on Field Instrumentation .pdf
A Presentation on Field Instrumentation .pdf
 
Importance and Practical application of Fluid Mechanics sessional
Importance and Practical application of  Fluid Mechanics sessionalImportance and Practical application of  Fluid Mechanics sessional
Importance and Practical application of Fluid Mechanics sessional
 
unit-5-flowmeasurement.pdf
unit-5-flowmeasurement.pdfunit-5-flowmeasurement.pdf
unit-5-flowmeasurement.pdf
 
Flow measurement
Flow measurementFlow measurement
Flow measurement
 
orifice meter and its application_ppt
orifice meter and its application_pptorifice meter and its application_ppt
orifice meter and its application_ppt
 
FLOW(NEW).pptx .
FLOW(NEW).pptx                          .FLOW(NEW).pptx                          .
FLOW(NEW).pptx .
 
Flow measuring devices - It contents all type of Flow Measuring devices like ...
Flow measuring devices - It contents all type of Flow Measuring devices like ...Flow measuring devices - It contents all type of Flow Measuring devices like ...
Flow measuring devices - It contents all type of Flow Measuring devices like ...
 
CHAPTER NO 2
CHAPTER NO 2 CHAPTER NO 2
CHAPTER NO 2
 
Flow measurement in industries
Flow measurement in industriesFlow measurement in industries
Flow measurement in industries
 
Stream flow
Stream flow Stream flow
Stream flow
 
UNIT 1 UNIFORM FLOW.pptx
UNIT 1 UNIFORM FLOW.pptxUNIT 1 UNIFORM FLOW.pptx
UNIT 1 UNIFORM FLOW.pptx
 
UNIFORM FLOW OCF.pptx
UNIFORM FLOW OCF.pptxUNIFORM FLOW OCF.pptx
UNIFORM FLOW OCF.pptx
 

Dernier

UiPath Studio Web workshop series - Day 6
UiPath Studio Web workshop series - Day 6UiPath Studio Web workshop series - Day 6
UiPath Studio Web workshop series - Day 6DianaGray10
 
AI Fame Rush Review – Virtual Influencer Creation In Just Minutes
AI Fame Rush Review – Virtual Influencer Creation In Just MinutesAI Fame Rush Review – Virtual Influencer Creation In Just Minutes
AI Fame Rush Review – Virtual Influencer Creation In Just MinutesMd Hossain Ali
 
Cybersecurity Workshop #1.pptx
Cybersecurity Workshop #1.pptxCybersecurity Workshop #1.pptx
Cybersecurity Workshop #1.pptxGDSC PJATK
 
ADOPTING WEB 3 FOR YOUR BUSINESS: A STEP-BY-STEP GUIDE
ADOPTING WEB 3 FOR YOUR BUSINESS: A STEP-BY-STEP GUIDEADOPTING WEB 3 FOR YOUR BUSINESS: A STEP-BY-STEP GUIDE
ADOPTING WEB 3 FOR YOUR BUSINESS: A STEP-BY-STEP GUIDELiveplex
 
20230202 - Introduction to tis-py
20230202 - Introduction to tis-py20230202 - Introduction to tis-py
20230202 - Introduction to tis-pyJamie (Taka) Wang
 
Nanopower In Semiconductor Industry.pdf
Nanopower  In Semiconductor Industry.pdfNanopower  In Semiconductor Industry.pdf
Nanopower In Semiconductor Industry.pdfPedro Manuel
 
Bird eye's view on Camunda open source ecosystem
Bird eye's view on Camunda open source ecosystemBird eye's view on Camunda open source ecosystem
Bird eye's view on Camunda open source ecosystemAsko Soukka
 
Videogame localization & technology_ how to enhance the power of translation.pdf
Videogame localization & technology_ how to enhance the power of translation.pdfVideogame localization & technology_ how to enhance the power of translation.pdf
Videogame localization & technology_ how to enhance the power of translation.pdfinfogdgmi
 
VoIP Service and Marketing using Odoo and Asterisk PBX
VoIP Service and Marketing using Odoo and Asterisk PBXVoIP Service and Marketing using Odoo and Asterisk PBX
VoIP Service and Marketing using Odoo and Asterisk PBXTarek Kalaji
 
Artificial Intelligence & SEO Trends for 2024
Artificial Intelligence & SEO Trends for 2024Artificial Intelligence & SEO Trends for 2024
Artificial Intelligence & SEO Trends for 2024D Cloud Solutions
 
IaC & GitOps in a Nutshell - a FridayInANuthshell Episode.pdf
IaC & GitOps in a Nutshell - a FridayInANuthshell Episode.pdfIaC & GitOps in a Nutshell - a FridayInANuthshell Episode.pdf
IaC & GitOps in a Nutshell - a FridayInANuthshell Episode.pdfDaniel Santiago Silva Capera
 
Igniting Next Level Productivity with AI-Infused Data Integration Workflows
Igniting Next Level Productivity with AI-Infused Data Integration WorkflowsIgniting Next Level Productivity with AI-Infused Data Integration Workflows
Igniting Next Level Productivity with AI-Infused Data Integration WorkflowsSafe Software
 
Anypoint Code Builder , Google Pub sub connector and MuleSoft RPA
Anypoint Code Builder , Google Pub sub connector and MuleSoft RPAAnypoint Code Builder , Google Pub sub connector and MuleSoft RPA
Anypoint Code Builder , Google Pub sub connector and MuleSoft RPAshyamraj55
 
UiPath Studio Web workshop series - Day 8
UiPath Studio Web workshop series - Day 8UiPath Studio Web workshop series - Day 8
UiPath Studio Web workshop series - Day 8DianaGray10
 
OpenShift Commons Paris - Choose Your Own Observability Adventure
OpenShift Commons Paris - Choose Your Own Observability AdventureOpenShift Commons Paris - Choose Your Own Observability Adventure
OpenShift Commons Paris - Choose Your Own Observability AdventureEric D. Schabell
 
Building Your Own AI Instance (TBLC AI )
Building Your Own AI Instance (TBLC AI )Building Your Own AI Instance (TBLC AI )
Building Your Own AI Instance (TBLC AI )Brian Pichman
 
The Data Metaverse: Unpacking the Roles, Use Cases, and Tech Trends in Data a...
The Data Metaverse: Unpacking the Roles, Use Cases, and Tech Trends in Data a...The Data Metaverse: Unpacking the Roles, Use Cases, and Tech Trends in Data a...
The Data Metaverse: Unpacking the Roles, Use Cases, and Tech Trends in Data a...Aggregage
 

Dernier (20)

UiPath Studio Web workshop series - Day 6
UiPath Studio Web workshop series - Day 6UiPath Studio Web workshop series - Day 6
UiPath Studio Web workshop series - Day 6
 
AI Fame Rush Review – Virtual Influencer Creation In Just Minutes
AI Fame Rush Review – Virtual Influencer Creation In Just MinutesAI Fame Rush Review – Virtual Influencer Creation In Just Minutes
AI Fame Rush Review – Virtual Influencer Creation In Just Minutes
 
Cybersecurity Workshop #1.pptx
Cybersecurity Workshop #1.pptxCybersecurity Workshop #1.pptx
Cybersecurity Workshop #1.pptx
 
ADOPTING WEB 3 FOR YOUR BUSINESS: A STEP-BY-STEP GUIDE
ADOPTING WEB 3 FOR YOUR BUSINESS: A STEP-BY-STEP GUIDEADOPTING WEB 3 FOR YOUR BUSINESS: A STEP-BY-STEP GUIDE
ADOPTING WEB 3 FOR YOUR BUSINESS: A STEP-BY-STEP GUIDE
 
20230202 - Introduction to tis-py
20230202 - Introduction to tis-py20230202 - Introduction to tis-py
20230202 - Introduction to tis-py
 
Nanopower In Semiconductor Industry.pdf
Nanopower  In Semiconductor Industry.pdfNanopower  In Semiconductor Industry.pdf
Nanopower In Semiconductor Industry.pdf
 
20230104 - machine vision
20230104 - machine vision20230104 - machine vision
20230104 - machine vision
 
20150722 - AGV
20150722 - AGV20150722 - AGV
20150722 - AGV
 
Bird eye's view on Camunda open source ecosystem
Bird eye's view on Camunda open source ecosystemBird eye's view on Camunda open source ecosystem
Bird eye's view on Camunda open source ecosystem
 
Videogame localization & technology_ how to enhance the power of translation.pdf
Videogame localization & technology_ how to enhance the power of translation.pdfVideogame localization & technology_ how to enhance the power of translation.pdf
Videogame localization & technology_ how to enhance the power of translation.pdf
 
VoIP Service and Marketing using Odoo and Asterisk PBX
VoIP Service and Marketing using Odoo and Asterisk PBXVoIP Service and Marketing using Odoo and Asterisk PBX
VoIP Service and Marketing using Odoo and Asterisk PBX
 
Artificial Intelligence & SEO Trends for 2024
Artificial Intelligence & SEO Trends for 2024Artificial Intelligence & SEO Trends for 2024
Artificial Intelligence & SEO Trends for 2024
 
IaC & GitOps in a Nutshell - a FridayInANuthshell Episode.pdf
IaC & GitOps in a Nutshell - a FridayInANuthshell Episode.pdfIaC & GitOps in a Nutshell - a FridayInANuthshell Episode.pdf
IaC & GitOps in a Nutshell - a FridayInANuthshell Episode.pdf
 
Igniting Next Level Productivity with AI-Infused Data Integration Workflows
Igniting Next Level Productivity with AI-Infused Data Integration WorkflowsIgniting Next Level Productivity with AI-Infused Data Integration Workflows
Igniting Next Level Productivity with AI-Infused Data Integration Workflows
 
Anypoint Code Builder , Google Pub sub connector and MuleSoft RPA
Anypoint Code Builder , Google Pub sub connector and MuleSoft RPAAnypoint Code Builder , Google Pub sub connector and MuleSoft RPA
Anypoint Code Builder , Google Pub sub connector and MuleSoft RPA
 
201610817 - edge part1
201610817 - edge part1201610817 - edge part1
201610817 - edge part1
 
UiPath Studio Web workshop series - Day 8
UiPath Studio Web workshop series - Day 8UiPath Studio Web workshop series - Day 8
UiPath Studio Web workshop series - Day 8
 
OpenShift Commons Paris - Choose Your Own Observability Adventure
OpenShift Commons Paris - Choose Your Own Observability AdventureOpenShift Commons Paris - Choose Your Own Observability Adventure
OpenShift Commons Paris - Choose Your Own Observability Adventure
 
Building Your Own AI Instance (TBLC AI )
Building Your Own AI Instance (TBLC AI )Building Your Own AI Instance (TBLC AI )
Building Your Own AI Instance (TBLC AI )
 
The Data Metaverse: Unpacking the Roles, Use Cases, and Tech Trends in Data a...
The Data Metaverse: Unpacking the Roles, Use Cases, and Tech Trends in Data a...The Data Metaverse: Unpacking the Roles, Use Cases, and Tech Trends in Data a...
The Data Metaverse: Unpacking the Roles, Use Cases, and Tech Trends in Data a...
 

Flow Like an Egyptian: The Basics of Open Channel Flow

  • 1. I’m Walt Boyes, and if you are like most automation professionals, you don’t do flow measurement design daily or even weekly. So some of the basics may be new to you… especially in the area of open channel flow. 1
  • 2. The picture you see is of a “Nilometer.” It is one of many devices built since 3000 BC to measure the height (and calculate the flow) of the Nile river in Egypt. It is very likely the first flowmeter, and it measures open channel flow. For the next few minutes, we are going to look at the theory and practice of open channel flow, and by the end of our time together, you will be able to “Flow Like an Egyptian.” 2
  • 3. There are two basic ways to measure flow in an open channel or conduit. The first is to use one of the formulas like Manning’s Equation, which have been developed for open channel flow in ditches, rivers, and canals. You must calculate a wetted perimeter, and know the slope of the conduit, and guess at the roughness of the bottom of the conduit, or pipe. The second method is to measure the height of the flowing stream at a known distance behind (upstream) of a predictable hydraulic jump, such as a flume or weir. 3
  • 4. In 1889, Irish engineer Robert Manning produced an equation for calculating flow in open conduits from the level in the channel. Manning's equation works best in man-made conduits because the hydraulic radius, slope and coefficient of friction can be better known or estimated. It will work in any open channel, but the error expands as these terms are less well known. Manning's equation, and its successors, are often used for calculating the flow in sewers and in man-made irrigation channels. Although tables of Manning's "n" are common, it is nearly impossible to accurately calculate "n," so it is almost always an educated guess, based on the engineer's experience and expertise. A small change in "n" can result in a large change in "V" and thus a large change in "Q." 4
  • 5. For real accuracy, the use of a primary device is required. These are restrictive devices placed in the flow stream that raise the height of the water behind the restriction to a predictable level based on volumetric flow. Typically, these devices are flumes and weirs. Weirs have been known for centuries, and were used as primitive spillways from small earthen dams. Measurement weirs come in several configurations: v-notch, rectangular and trapezoidal, among others. The U. S. Department of the Interior’s Bureau of Reclamation publishes an online version of its comprehensive "Water Measurement Manual" which details all the various types of weirs and flumes, and how to install them and maintain them. In a v-notch weir, all the water flows through the weir, and the level is measured at a known point behind (upstream) of the weir. This level forms the "H" in our formula. Sometimes, if very high accuracy is required at the lowest flow rates, a compound weir can be used. This is often a rectangular weir with a sharp vnotch forming the bottom of the weir. Thus, the rectangular weir equation can be used for high flows, and once the flow reduces to below the zero point of the rectangular weir, the v-notch equation is used. Many open channel flow transmitters have the ability to switch equations like this. 5
  • 6. Note that I said flow transmitter not flow meter. That’s because the primary device is itself the flow meter. All the transmitter does is to automate the staff gauge. As with the Nilometer, a primary device can measure flow using the calibrated Mark 1 eyeball. What the various types of flow transmitters do is to make it unnecessary for somebody to stand there and eyeball the primary device. 6
  • 7. Flumes have a constriction in the flow, and a "hydraulic jump" that causes the head height to be linear and repeatable. There are dozens of kinds of flumes. In modern times, the most common are the Parshall and the Palmer-Bowlus flumes. Parshall flumes are commonly used for flow measurement at the inlet and outlet to wastewater treatment plants and surface water intakes for treatment plants and power plants. Typically, a Parshall flume is supplied as a fiberglas "liner" that is installed and then cemented in place. In this picture, the flume is cutaway so you can clearly see the hydraulic jump. 7
  • 8. Palmer-Bowlus flumes were originally developed for measurement in sewers and other open conduits with relatively low flow. There is no constriction, as with a Parshall flume, but there is a complex hydraulic jump that forms the point where the height is directly proportional to flow rate, the "H" in our equation. 8
  • 9. Here’s the equation for flumes and weirs. Note how critical the measurement of H, liquid level, is. There are many tables of coefficients and examples of how to calculate flow. Flow transmitters all have equations built into them. 9
  • 10. For a flume or weir to be accurate, it must be installed properly. Most error problems with open channel flow measurements are traceable to the accuracy of the flume or weir, not the level measurement or the flow transmitter. All flumes and weirs must be installed as close to perfectly level inlet-to-outlet as possible, and side-to-side, too. Fiberglass flumes often "bow in" when concrete is poured behind them, and this produces unexpected inaccuracies, which may not be able to be calibrated out, except by in-situ flow testing and the use of a strapping table in the flow transmitter. All flumes and weirs have what is called the "submergence point" where the level goes above the measurement range of the device. Flow may continue to be moving in either direction during submergence, but the measurement is meaningless during that condition. 10
  • 11. 11
  • 12. A small compressor pumps air into a reservoir. This air is released slowly by a needle valve into a bubble line, a length of small diameter flexible tubing. The other end of this tube is submerged in the flow stream. Inside the flow transmitter, the bubble line also connects to one side of a differential pressure transducer. As air is released slowly into the bubble line by the needle valve, pressure builds inside the line to force the air out of the line into the flow stream. When there is enough pressure to counteract the hydrostatic pressure of the flow stream, a bubble is forced from the end of the line. The amount of pressure required to force the bubble from the end of the line is directly dependent on the hydrostatic pressure of the flow stream over the end of the bubble line. The pressure transducer inside the flow meter senses this pressure and converts it into an electrical signal that the flow transmitter converts into level. From the measured level detected by the bubbler the flow meter then calculates flow rate and total flow. 12
  • 13. You can still find capacitance or RF Admittance Flow Transmitters for open channel flow, like this one. The capacitance or admittance changes with the level on the sensor, and the level signal is then converted to flow. These sensors have lots of issues, especially with grease or foam in wastewater or irrigation, but they work very well in small flumes and weirs. 13
  • 14. Originally a purely mechanical measurement, with a windup chart recorder, float and tape flowmeters are still in use all over the world, mostly for stream gauging for organizations like USGS. The movement of the float drives a cam operated pen across the chart. Simple, effective, accurate, and doesn’t require power. The operator winds the chart motor every week or so, when he comes to change the chart. 14
  • 15. Ultrasonic open channel flowmeters have become the workhorse of the industry. They are non-contacting, and they are very accurate if installed correctly. Note that the picture shows that it isn’t just a matter of sticking a sensor over a flume or weir. For example, the plastic condolet and the flex conduit are there not to make the mounting easy but to damp ringing of the sensor. Think of the sensor as a drum that is struck every n times a second. It beats, then listens for the echo. The time difference between the time the drumbeat left the sensor and the time the return signal arrives gives the distance to the liquid height. The key to good applications is to mount the sensor so that it is absolutely vertical, and far enough away from the channel wall so it doesn’t get a signal back from the hard surface. Such signals sometimes overpower the circuitry in the flow transmitter. Wind, foam, steam and other off-gases interfere, sometimes terminally, with ultrasonic open channel flowmeters. 15
  • 16. Both guided wave and downlooking radar transmitters have been used for open channel flow where wind or other interference makes it impossible to use ultrasonic flow sensors. 16
  • 17. Just like its ancient predecessor, the Nilometer, the staff gauge is a ruler stuck in the flow with its end point at the arbitrary zero flow point. It is read by the calibrated MK I Eyeball. 17
  • 18. Area-velocity flow meters are based on the theory that there is a point in the flow in an open conduit where the measured flow is equal to the average flow rate in the fluid. These flow meters are usually used for sewer flow and sewer capacity and surcharge studies, since the velocity sensor is designed to be bidirectional. Sensors that have been used include differential pressure, ultrasonic and radar for the top level, and ultrasonic (doppler type) and electromagnetic for the velocity. Proponents of this theory say that Q=VA works with this methodology. However, a cautionary tale. Quite a few years ago, a consulting engineer doing a flow study for a large city in New Jersey found data from one A-V flowmeter that indicated that Manhattan had been underwater up to the top of the Empire State Building. 18
  • 19. Area-velocity flow meters being problematic, a flow meter was designed with a special purpose (and highly calibratable) primary device for measuring sewer flows and surcharges. It was called the DataGator, and is still available from Renaissance Instruments. It won an R&D100 award the year it was introduced. It is the only third-party calibratable flow meter for use in sewers. There are four categories of flow that the DataGator works in. For free flow, it works like a standard flume. In submerged flow, it operates using its proprietary flume design. In full pipe flow at transition (from submerged to pressurized) it works like a calibrated venturi tube. And the venturi measurement continues when the pipe is full and the measurement is fully bidirectional. 19
  • 20. If you’ve followed me so far, you get a gold star…and Continuing Education Units! 20