UltraSPARC T2:                                                                              • Up to 8 cores @1.2GHz or 1.4GHz
TrueSystem On a Chip                                                                        • Up to 64 threads per CPU
                                                                                            • Up to 16 FB-DIMMs, 4 memory
                                                                                              controllers
       FB DIMM       FB DIMM      FB DIMM        FB DIMM
                                                                                                 > Up to 64GB memory (4GB DIMMs)
                                                                                                 > 2.5x memory BW of UltraSPARC T1
       FB DIMM       FB DIMM      FB DIMM        FB DIMM                                    • 8 x fully pipelined Floating Point units /
                                                                                              core, 1 per core
           MCU       MCU            MCU           MCU
                                                                                            • Dual 10Gbit Ethernet and PCI-E
                                                                                              integrated onto chip
      L2$ L2$ L2$ L2$ L2$ L2$ L2$ L2$
                                                                                            • 4MB L2 (8 banks) 16 way associative
                         Full Cross Bar                                                     • Enhanced MAU/Security co-processor
      C0     C1    C2      C3    C4       C5    C6       C7                                   per core
     FPU     FPU   FPU     FPU   FPU      FPU   FPU     FPU
     MAU     MAU   MAU     MAU   MAU      MAU   MAU     MAU
                                                                                                 > DES, 3DES, AES, RC4, SHA1,
                     DMA Sub-System                                                                SHA256, MD5, RSA to 2048 key,
                                                                                                   ECC,CRC32
        NIU                 Sys I/F
                                                                                            • Advanced Power saving features
      (E-net+)        Buffer Switch Core              PCI-E
                                                                                            • 65nm process technology
                         Power ~95W
                         <1.5W/thread         x8 @2.5GHz
  2x 10GE Ethernet                        4GBytes/s bi-directional
                                                              Sun Internal and Approved Partners Only                                      2
UltraSPARC T2 Processor
                                                                                                                  SPC SPARCv9 CMT Core
             L2 Data                                                                          L2 Data

             Bank 0                                                                           Bank 4              CCX Core-Cache Crossbar
              L2B0           SPARC    SPARC           SPARC              SPARC                 L2B4               L2$ Level 2 Cache Bank
             L2 Data
                             Core 0   Core 1          Core 5             Core 4
                                                                                              L2 Data             CLC Coherence & Link Controller
             Bank 1                                                                           Bank 5              MCU Memory Control Unit
              L2B1                                                                             L2B5               SIU System Interface Unit
                              L2       L2              L2                  L2
           MCU0                                                                                    MCU2           NCU Non-cacheable Unit
                       NCU




                             TAG0     TAG1            TAG5               TAG4                               FSR
                                                                                                                  MAC Media Access Controller




                                                                                       EFU
           MCU1                                                                                    MCU3

                                                                                                                  DMU Data Management Unit




                                                                   SIO
                                SII




              L2B3                             CCX                                             L2B7
     FSR                                                                    CCU                                   PEU PCI Express Unit
             L2 Data                                                                          L2 Data
             Bank 3                                                                           Bank 7
                              L2       L2              L2                  L2
              L2B2                                                                             L2B6
                             TAG2     TAG3            TAG7                TAG6
             L2 Data                                                                          L2 Data

             Bank 2                                                                           Bank 6


                             SPARC    SPARC           SPARC              SPARC
              DMU
                             Core 2   Core 3          Core 7             Core 6              RDP          TDS


              PEU


                                                                                                   RTX
             PSR               ESR              FSR                      MAC


For a video tour with Rick Hetherington, go to http://www.youtube.com/watch?v=B8DNexYcsa4
                                                 Sun Internal and Approved Partners Only                                                     3
UltraSPARC T2 Plus:                                                                                • Per Socket
   Multi-Socket US T2                                                                                   > Up to 8 cores @1.2GHz or
Each Coherency Link 6.4GBytes/s per direction, 12.8GB/s total
                                                                                                           1.4GHz
   4 x Coherency links give Snoop bandwidth of 51.2GB/s                                                 > Up to 64 Threads per socket
                                                                          4x
                                                                       Coherency                        > 4MB L2$ 8 banks x 16 Way SA
                                                                         Links
                                                                                                        > Up to 8 FPU's, 1 per core
             FB-DIMM   FB-DIMM              FB-DIMM   FB-DIMM
                                                                                                        > Up to 8 Crypto cores, 1 per core
             FB-DIMM   FB-DIMM              FB-DIMM   FB-DIMM                                                    > DES, 3DES, AES, RC4, SHA1, SHA256,
                                                                                                                   MD5, RSA to 2048 key, ECC,CRC32

                   MCU                            MCU
                                                                                                             > 2 memory Controllers, 16 DIMMS
             CU              CU             CU              CU                                               > 25Read+13WriteGB/s Memory BW
        L2$ L2$ L2$ L2$ L2$ L2$ L2$ L2$                                                                      > One x8 PCIe interface
                          Full Cross Bar                                                            • Per system
        CO        C1    C2        C3   C4        C5    C6        C7                                     > 2 sockets glue-less
        FPU    FPU     FPU       FPU   FPU    FPU     FPU       FPU                                     > 4 sockets using UST2 Plus XBR
        MAU    MAU     MAU       MAU   MAU    MAU     MAU       MAU
                                                                                                        > 16 or 32 PCIe lanes on 2 or 4
        System I/F                     PCI-Express                                                         Socket systems
                                                                                                    • 65nm process technology
             SSI                                      x8 @2.5GHz
             Bus        Power ~105W                    4GBytes/s
                        <1.5W/thread                  bi-directional

                                                                       Sun Internal and Approved Partners Only                                          4
UltraSPARC T2 Plus Processor
                                                         SPC SPARCv9 CMT Core
                                                         CCX Core-Cache Crossbar
                                                         L2$ Level 2 Cache Bank
                                                         CLC Coherence & Link Controller
                                                         MCU Memory Control Unit
                                                         SIU System Interface Unit
                                                         NCU Non-cacheable Unit
                                                         NCX Non-cacheable Crossbar
                                                         DMU Data Management Unit
                                                         PEU PCI Express Unit




               Sun Internal and Approved Partners Only                                 5
CMT Processor Comparison
                                  UltraSPARC T1              UltraSPARC T2      UltraSPARC T2 Plus
Technology                             90nm                       65nm                  65nm
# of Cores                                 8                         8                     8
# of Threads                              32                        64                     64
# of Sockets                               1                         1                   1–4
Core Frequency (Ghz)                   1 – 1.4                   1.2 – 1.4             1.2 – 1.4
Execution pipelines per core               1                         2                     2
Instructions per cycle per pipe            1                         1                     1
FPUs per chip                              1                         8                     8
I$ size (per core)                      16KB                       16KB                  16KB
D$ size (per core)                       8KB                       8KB                    8KB
L2$ size/Set Association           3MB/12-Way                 4MB/16-Way            4MB/16-Way
Memory Type                            DDR2                    FBDIMM-1               FBDIMM-1
Memory Bandwidth (GB/s)                  21.3                42READ + 21WRITE      25READ + 13WRITE
Coherence Bandwdth (GB/s)                  -                         -          4 x (6.4READ +6.4WRITE)
IO Bus                                  JBUS                     x8 PCIe               x8 PCIe
IO Bandwidth (GB/s)                       2.5                      2+2                   2+2
On-chip Networking                         -                    2 x 10GE                    -
Crypto Acceleration                      RSA              RSA, RC4, DES, 3DES, AES, SHA1-256, MD5
Power (Watts, Watts/thread)           72, 2.25                     95, 1.5           105, 1.6 *



                                    Sun Internal and Approved Partners Only                               6
UltraSPARC T2 Plus 2-Socket System

                                                               Coherency Links
       Dual Channel                Dual Channel                                              Dual Channel                 Dual Channel
         FBDIMM                      FBDIMM                                                       FBDIMM                    FBDIMM




      Memory Controller           Memory Controller                                              Memory Controller        Memory Controller

   Coherence      Coherence    Coherence   Coherence                                   Coherence           Coherence   Coherence   Coherence
     Unit             Unit        Unit          Unit                                       Unit              Unit        Unit            Unit


  UltraSPARC T2 Plus Cores, Crossbar, L2$                                            UltraSPARC T2 Plus Cores, Crossbar, L2$
               (8 cores, 64 threads, 4MB L2$)                                                         (8 cores, 64 threads, 4MB L2$)



            PCI-Express             NCU, DMU           NCX                                          PCI-Express            NCU, DMU             NCX




                                  System IO (Network, Disk, etc.)

                                                       Sun Internal and Approved Partners Only                                                        7
UltraSPARC T2/Plus CPU Core Block Diagram
                                                            • IFU – Instruction Fetch Unit
                                                               > 16 KB I$, 32B lines, 8-way SA
    TLU          IFU                                           > 64-entry fully-associative ITLB
                                                            • EXU0/1 – Integer Execution Units
                                                              > 4 threads share each unit
                                                              > Executes one integer
                                                                instruction/cycle
          EXU0         EXU1
                                                            • LSU – Load/Store Unit
                                                              > 8KB D$, 16B lines, 4-way SA
                                 MMU/                         > 128-entry fully-associative DTLB
                                 HWTW                       • FGU – Floating/Graphics Unit
                                                            • SPU – Stream Processing Unit
                                                              > Cryptographic acceleration
  SPU     FGU      LSU
                                                            • TLU – Trap Logic Unit
                                                              > Updates machine state, handles
                                                                 exceptions and interrupts
                                                            • MMU – Memory Management Unit
                                                              > Hardware tablewalk (HWTW)
                   Gasket                                        – TLB miss handled by hardware
                                                              > 8KB, 64KB, 4MB, 256MB pages
                  xbar/L2
                              Sun Internal and Approved Partners Only                              8
Floating Point Unit

    • Each Core has its own Floating Point Unit. This removes
      completely the 2% FP restriction of T1.
    • Only a 6 cycle penalty to the FPU
      > T1 required upwards of 28 cycles
    • Fully-pipelined (except divide/sqrt)
            Data
      > Divide/sqrt in parallel with add or multiply operations of other
         threads
    • Full VIS 2.0 implementation in hardware, no emulation
    • FPU performs integer multiply, divide, population count
    • Multiplier incorporates enhancements for offloading modular
      arithmetic operations to the Crypto Unit



●


●                           Sun Internal and Approved Partners Only        9
FB-DIMM Memory Interface


             Feature        UltraSPARC T1                       UltraSPARC T2          UltraSPARC T2 Plus
     Require Pins                1000                                440                         208
     Available Bandwidth    23GBytes/second                  50Gbytes/second          37.5Gbytes/second/socket
                                                            Up to 64x DIMM slots     Up to 32x DIMM slots/socket
     Memory Capacity       up to 16x DIMM slots
                                                          T5x20 uses 16 DIMM slots   T5x40 uses 8/16 DIMM slots
              Data
     Memory Controllers            4                                  4                           2
     Memory Latency              96ns                               126ns                       126ns
     DIMM speeds                400MHz                             667MHz                      667MHz
     DIMM Power               7watts/DIMM                     12.5Watts/DIMM               12.5Watts/DIMM




●


●                                      Sun Internal and Approved Partners Only                                     10
10/100/1000/10GbE Network Interfaces
    • Uses the Neptune Chip on the Motherboard which provides
      > Two RJ-45 ports dedicated for 10/100/1000
      > Two RJ-45 ports capable of 10/100/1000
         – Fitting a XAUI adapter disables the one of these ports per XAUI
    • Same 10 GbE XAUI cards as T5x20 server
    • 16 Rx and 24 Tx DMA channels for virtualization
         – Integrated NIU in T2 has 16 Tx channels
            Data
               – Raw UDP Tx performance on Neptune > T2 NIU
         – T2 processor network typically outperforms Neptune on most network
           benchmarks
    • Packet classification
      > Rx data can be HW classified at layer 2 ,3 and 4
         – Put into the separate Rx DMA buffers by classification rules
    • Same 'nxge' device driver as T2 NIU.
    • Performance estimates, testing/tuning ongoing
         – 1 port 10GbE TX/RX = 9.3 Gbps with CPUs still 65-75% idle
●
         – 2 port 10GbE TX/RX = 12-19Gbps (better if dedicate RX/TX ports)
●                              Sun Internal and Approved Partners Only          11
T5140/T5240                                                  Extreme Rackmount Density
 Dual UltraSPARC T2 Plus                                          • 1 / 2RU chassis, 28” depth
                                                                  • Two sockets
                                                                     > Up to 8 cores @ 1.2GHz at RR
                                                                                   – 1.4GHz to follow
                                                                     > Up to 128 threads
                                                                  • 161U/2U/ 322U FB-DIMM memory slots
                                                                     > 64/128GB of memory, 4GB DIMMs
                                                                  High Reliability
• Up to 128 threads / 128GB memory / 128                          • Up to 4 (1U) or 8/16 (2U) Hot-Plug
  LDoms in a 1U / 2U redundant chassis                              SATA/SAS 2.5” HDD (Raid 0,1)
                                                                        > RAID 5 BBWC card post-RR
• Over 5,100 threads per rack !
                                                                  • Redundant, hot-swappable PSUs and
• High RAS and I/O bandwidth                                        Fans. DC Option for 2U
                                                                  • Certain Configs are 'Hi-Line Power' only
• Scale-Up / Scale-Out of application
  infrastructure                                                  Expandable
                                                                  • 3/6 PCI-E expansion slots
                                                                        > including 2 x 10 GBE I/0 XAUI slots
                                                                  • 4 x 1GbE Ethernet as standard
                                                                  • 4 USB ports
                                Sun Internal and Approved Partners Only                                     12
T5x40 Standard Configurations (PTO)
   Part Number                     Description 1RU
                 2 x 4 Core, 64 Threads, 1.2Ghz, 8GB (8 X 1GB),
    SETPAAE1Z
                 4 disk capable, 2x 146GB disks, 2x 720W PSU, DVD
                 2 x 6 Core, 96 Threads, 1.2Ghz, 16GB (8 X 2GB),
    SETPBGE1Z
                 4 disk capable, 2x 146GB disks, 2x 720W PSU, DVD
                 2 x 8 Core, 128 Threads, 1.2Ghz, 32GB (16 X 2GB),
    SETPCJE1Z
                 4 disk capable, 2x 146GB disks, 2x 720W PSU, DVD
                 2 x 8 Core, 128 Threads, 1.2Ghz, 64GB (16 X 4GB),
    SETPCPE1Z
                 4 disk capable, 2x 146GB disks, 2x 720W PSU, DVD
   Part Number                     Description 2RU
                 2 x 6 Core, 96 Threads, 1.2Ghz, 8GB (8 X 1GB),
    SEUPBAE1Z
                 8 disk capable, 2x 146GB disks, 2x 1100W PSU, DVD
                 2 x 8 Core, 128 Threads, 1.2Ghz, 32GB (16 X 2GB),
    SEUPCJE1Z
                 8 disk capable, 2x 146GB disks, 2x 1100W PSU, DVD
                 2 x 8 Core, 128 Threads, 1.2Ghz, 64GB (16 X 4GB),
    SEUPCPE1Z
                 8 disk capable, 2x 146GB disks, 2x 1100W PSU, DVD
                 2 x 8 Core, 128 Threads, 1.2Ghz, 64GB (16 X 4GB),
    SEUPCPE2Z    16 disk capable, 2x 146GB disks, 2x 1100W PSU, DVD
                 HIGHLINE POWER ONLY (220VAC)
                 2 x 8 Core, 128 Threads, 1.4Ghz, 64GB (16 X 4GB),
    SEUPDPE1Z    16 disk capable, 2x 146GB disks, 2x 1100W PSU, DVD
                 HIGHLINE POWER ONLY (220VAC)

                              Sun Internal and Approved Partners Only   13
Sun Fire T1000/T5120/T5140 Differences


         Feature           Sun Fire T1000                 SPARC Enterprise T5120 SPARC Enterprise T5140
  Form Factor               1U, 18¾” deep                          1U, 28” deep                 1U, 28” deep
                            UltraSPARC T1                         UltraSPARC T2           2x UltraSPARC T2 Plus
  CPU
                        1.0 GHz, 16-32 threads              1.2/1.4 GHz 32-64 threads   1.2/1.4 GHz 64-128 threads
                           DDR2 32GB Max                       FB-DIMM 64GB MAX            FB-DIMM 64GB MAX
  Memory
                                8x slots                             16x slots                   16x slots
                                                                                                4 x 1GbE or
  Network                      4 x GbE                          4 x GbE + 2 x 10GbE      3 x 1Gbe + 1 x 10GbE or
                                                                                           2 x 1GbE + 2 x 10GbE
                      1x 3.5” SATA, non-hot-swap
  Internal Storage                               Up to 8 x 2.5” SAS, hot-swap Up to 4 x 2.5” SAS, hot-swap
                            OR 2x 2.5” SAS
  Removable Media                 None                   1x DVD-RW                    1x DVD-RW
  Serial                   1x RS-232, No USB          1x RS-232, 4x USB            1x RS-232, 4x USB
  PCI Express slots          1x (low profile)           3x(low profile)              3x(low profile)
                              1x 300W AC          2x 650W AC & DC option               2x 720W AC
  Power Supply
                            Non-Redundant           Redundant/Hot-Swap           Redundant/Hot-Swap
  Fans                       Non-Hot-Swap         4 x Redundant/Hot-Swap       6 x Redundant/Hot-Swap

                                      Sun Internal and Approved Partners Only                                        14
Sun Fire T2000/T5220/T5240 Differences


        Feature         Sun Fire T2000                SPARC Enterprise T5220 SPARC Enterprise T5240
 Form Factor                2U, 24” deep                       2U, 28” deep                 2U, 28” deep
                          UltraSPARC T1                       UltraSPARC T2           2x UltraSPARC T2 Plus
 CPU
                     1.0 - 1.4GHz 32 threads              1.2/1.4 GHz 64 threads    1.2/1.4 GHz 64-128 threads
                        DDR2, 64GB MAX                     FB-DIMM, 64GB MAX           FB-DIMM 128GB MAX
 Memory
                              16x Slots                          16x Slots                    32x slots
                                                                                             4 x GbE or
 Network                     4x GbE                                                   3 x GbE + 1 x 10GbE or
                                                             4x GbE + 2x 10GbE          2 x GbE + 2 x 10GbE
 Internal Storage     4x 2.5” SAS, hot-swap               8 x 2.5” SAS, hot-swap   Up to 16 x 2.5” SAS, hot-swap
 Removable Media           1x DVD-ROM                         1x DVD-RW                    1x DVD-RW
 Serial                 1x RS-232, 4x USB                  1x RS-232, 4x USB            1x RS-232, 4x USB
 PCI Express slots        3x (low profile)                   6x (low profile)             6x (low profile)
 PCI-X slots              2x (low profile)                        None                         None
                            2x 450W AC                        2x 750W AC           2x 1100W AC/2 x1200Watt DC
 Power Supply
                       Redundant/Hot-Swap                 Redundant/Hot-Swap           Redundant/Hot-Swap
 Fans                3 x Redundant Hot-Swap             3 x Redundant Hot-Swap       5x Redundant/Hot-Swap


                                      Sun Internal and Approved Partners Only                                      15
Front Panel
                                                                                      Dual USB 2.0 ports


 Locator LED
         /Button
                                                                      DVD-RW                                  Disk Drive Map
 Fault LED                                                                                                    Top Fault LED
 Status LED
 Power Button         DISK 0   DISK 1                                       DISK 2     DISK 3                 PSU Fault LED
                                                                                                              Temp Fault LED


Serial Number label




 Locator LED
         /Button
 Fault LED
 Status LED                                                                                                   Top Fault LED
 Power Button                                                                                                 PSU Fault LED
                                                                                                              Temp Fault LED
                      DISK 1   DISK 3               DISK 5            DVD-ROM
                                                                                                              Disk Drive Map
Serial Number         DISK 0   DISK 2               DISK 4                  DISK 6     DISK 7

                                                                                                           Dual USB 2.0 ports
                      DISK 3   DISK 7                                       DISK 12    DISK 15
                      DISK 2   DISK 6                                       DISK 11    DISK 14
                      DISK 1   DISK 5                DISK 9           DVD-RW
                      DISK 0   DISK 4                DISK 8                 DISK 10    DISK 13
                                  Sun Internal and Approved Partners Only                                                  16
Rear Panel

                                           PCI/XAUI 0                           PCI/XAUI 1             PCI 2
PSU      PSU 0       PSU 1
Status
LED's

                          Chassis
                        Status LED's                                        Quad Gigabit        Dual   POSIX DB-9
                     and Locator Button                                     Ethernet Ports     USB 2.0 Serial Port
                                             SP           SP                                    Ports
                                            Serial      Network
                                             Port        Port




            PSU 1
                                             PCI 3                               PCI 4            PCI 5
                                          PCI/XAUI 0                         PCI/XAUI 1           PCI 2
            PSU 0


                        Chassis
          PSU         Status LED's                                       Quad Gigabit                   POSIX DB-9
          Status                                                                              Dual
                   and Locator Button                                    Ethernet Ports      USB 2.0     Serial Port
          LED's
                                           SP          SP                                     Ports
                                          Serial     Network
                                           Port       Port


                                                   Sun Internal and Approved Partners Only                             17
T5140 Block Diagram
                                                                                             CL
                                                                                                                                                                     1RU=16 DIMMS




                                                                          x8          SSI                  x8         SSI

                                                                x4
                                      x4                                PCIe          x8          x8
                                                                                                         PCIe
                                            LSI                 x1
                                                                       Switch                           Switch
Disk Chassis                               1068E                      PLX 8548                         PLX 8548                                         FPGA
1RU=4 Disks
                                                                                                          x8    x8
                                                       PCIe          x8
                                                        to x4                                                                 NEPTUNE
                                                       PCI
                                                                                                                               Ethernet
                                             33MHz                             XAUI                XAUI                        2 x 10/100/1000
                                                                                                                            2 x 10/100/1000/10000
                                             32bit


               USB      2.0
              to IDE            PCI
                                 to                                                                                                                            MPC885
   DVD                          USB                                                                                                                              ILOM
              USB 2.0     2.0                                                                                                   QUAD GbE                        Service
               Hub
                                                                                                                                  PHY
                                                                                                                                BCM5466R
                                                                                                                                                               Processor
   USB
                              2.0



Front Panel                                                                                                             0        1         2        3
                         USB                         PCIe                 PCIe                 PCIe                               Quad GbE                     Serial Network POSIX
 Rear Panel                                           x16                  x8                   x8                                Connectors                    Mgt    Mgt Serial DB-9
                                                     Slot2                Slot1 Internal and Approved Partners Only
                                                                            Sun                Slot0                                                                                18
T5240 Block Diagram
                                        2RU Memory Mezzanine Tray                                       2RU=16 DIMMS without Mezannine, 32 DIMMS with mezannine
                                                Option
                                                                                                  CL




                                                                              x8           SSI                 x8         SSI

                                                                 x4
                                       x4                                   PCIe           x8          x8
                                                                                                              PCIe
                                             LSI                 x1
                                                                           Switch                            Switch
Disk Chassis                           x4   1068E                         PLX 8548                          PLX 8548                                        FPGA
2RU = 8 or 16 Disks
                                                                                                       x8     x8     x8
                                                        PCIe             x8    x8    x8
                                                         to x4                                                                    NEPTUNE
                                                        PCI
                                                                                                                                   Ethernet
                                              33MHz                                 XAUI               XAUI                        2 x 10/100/1000
                                                                                                                                2 x 10/100/1000/10000
                                              32bit


                 USB     2.0
                to IDE           PCI
                                  to                                                                                                                               MPC885
   DVD                           USB                                                                                                                                 ILOM
                                                                      2RU                   2RU                2RU
               USB 2.0     2.0                                                                                                      QUAD GbE                        Service
                Hub
                                                                                                                                      PHY
                                                                                                                                    BCM5466R
                                                                                                                                                                   Processor
   USB
                               2.0



Front Panel                                                                                                                 0        1         2        3
                          USB                         PCIe       PCIe         PCIe      PCIe       PCIe PCI-                          Quad GbE                     Serial Network POSIX
 Rear Panel                                            x16        x8           x8        x8         x8     ex8                        Connectors                    Mgt    Mgt Serial DB-9
                                                      Slot2      Slot5        Slot1 Internal and Approved Partners Only
                                                                                Sun Slot4          Slot0 Slot3                                                                        19
Internal View (T5140)                                                                                      Fault Remind   System Configuration      Service Processor
                                                                                                                   Button      Card (SCC)EEPROM




                                          FB0/FM0

                                                     FB1/FM0
                                          FB0/FM0




                                                                      UltraSPARC UltraSPARC
                                                                      UltraSPARC UltraSPARC
                                                                                                                                                                       PCIe Slot 2




                                                                       T2 Plus 0
                                                                       T2 Plus 0
                                                                                                                                                                      x16(m)/x8(e)
                                                                                                      FB-DIMMs

                                          FB0/FM1

                                                     FB1/FM1
                                          FB0/FM1
                                                                                                                                                                      PCIe Slot 1
                                                                                                                                                                      x8(m)/x8(e)
                                                                                                                                                                          or
                                                                                                                                                                        XAUI 1




                                                                                  T2 Plus 1
                                                                                  T2 Plus 1
                   Disk
                  Chassis                                                                            FB-DIMMs
                                                     FB1/FM2
                                           FB0/FM2




                                                                                                                                                                      PCIe Slot 0
                                                                                                                                                                      x8(m)/x8(e)
                                                                                                                                                                          or
                                                                                                                                                                        XAUI 0



                                                                                                                                                                     Neptune
                                                                                                                                             PSU1                  Network ASIC
                                                                      Power                                       Power
                                                                      Board                                      Supplies
                                                                                                                                             PSU0


SAS x4 cable to                                                Power BUS Bars                             Memory Mezannine Connectors
 Disk Chassis     6 Fan Assemblies are required                                                                                              X4 SAS Connector 0 (cable attached)
                                                               RED = +12Volts                                 (not used on T5140)           X4 SAS Connector 1 (not used in 1RU)
                    (chassis can take up to 8)                 BLUE = Ground
                                                                                              Chassis Intrusion Reed Switch
                                                                                               (magnet on underside of lid)
                                                                   Sun Internal and Approved Partners Only                                                                    20
Internal View (T5240 without Mezzanine)                                                           Fault Remind   System Configuration      Service Processor
                                                                                                     Button      Card (SCC)EEPROM




                            FB0/FM0

                                       FB1/FM0
                            FB0/FM0
                                                                                                                                                          PCIe Slot 2




                                                        UltraSPARC UltraSPARC
                                                        UltraSPARC UltraSPARC
                                                                                                                                                          x8(m)/x8(e)




                                                         T2 Plus 0
                                                         T2 Plus 0
                                                                                                                                                         x16(m)/x8(e)
                                                                                     FB-DIMMs


                                                                                                                                                         PCIe Slot 1
                                                                                                                                                         x8(m)/x8(e)
                                                                                                                                                         x8(m)/x8(e)
                           FB0/FM1

                                      FB1/FM1
                           FB0/FM1

                                      FB1/FM1
                                                                                                                                                             or



                                                                    T2 Plus 1
                                                                    T2 Plus 1
                                                                                                                                                           XAUI 1

     Disk
    Chassis                                                                          FB-DIMMs
                                                                                                                                                        PCIe Slot 0
                                                                                                                                                        x8(m)/x8(e)
                                                                                                                                                        x8(m)/x8(e)
                                                                                                                                                            or
                                                                                                                                                          XAUI 0
                          FB0/FM2
                          FB0/FM2




                                                               Power                                Power                  PSU's
                                                               Board                               Supplies               Vertically
                                                                                                                          Stacked


                                                 Power BUS Bars                             Memory Mezannine Connectors        X4 SAS Connector 0 (cable attached)
    5 Fan Assemblies are required                RED = +12Volts                                                               X4 SAS Connector 1 (not used in 1RU)
      (chassis can take up to 6)                 BLUE = Ground
                                                                                Chassis Intrusion Reed Switch
                                                                                 (magnet on underside of lid)
                                                     Sun Internal and Approved Partners Only                                                                     21
Internal View (T5240 with Mezzanine)                           Mezzanine Air           Fault Remind   System Configuration   Service Processor
                                                                  Guide                   Button      Card (SCC)EEPROM




                           FB0/FM0

                                     FB1/FM0
                                     FB1/FM0
                                                                                                                                           PCIe Slot 2
                                                                                                                                           x8(m)/x8(e)
                                                                                                                                          x16(m)/x8(e)
                                                                       FB-DIMMs


                                                                                                                                          PCIe Slot 1
                                                                                                                                          x8(m)/x8(e)
                                                                                                                                          x8(m)/x8(e)
                           FB0/FM1

                                     FB1/FM1
                           FB0/FM1

                                     FB1/FM1
                                                                                                                                              or
                                                                                                                                            XAUI 1

     Disk
    Chassis                                                            FB-DIMMs
                                                                                                                                          PCIe Slot 0
                                                                                                                                          x8(m)/x8(e)
                                                                                                                                          x8(m)/x8(e)
                                                                                                                                              or
                                                                                                                                            XAUI 0
                          FB0/FM2
                          FB0/FM2




                                                         Power                           Power                  PSU's
                                                         Board                          Supplies               Vertically
                                                                                                               Stacked


                                               Power BUS Bars                  Memory Mezannine Handles
    5 Fan Assemblies are required              RED = +12Volts
      (chassis can take up to 6)               BLUE = Ground
                                                                Chassis Intrusion Reed Switch
                                                                 (magnet on underside of lid)
                                                   Sun Internal and Approved Partners Only                                                        22
Motherboard Memory Physical Layout
Chassis                                                                                                                              Chassis
Front                                                                                                                                Rear
                                                               Channel0/DIMM 1/Branch 1
                                                                   CMP0/Branch1/Channel1/DIMM0              1
                                                               Channel0/DIMM 1/Branch 1
                                                                   CMP0/Branch1/Channel1/DIMM1
                                                                           3                                2

                                                              Channel0/DIMM 1/Branch 1
                                                                  CMP0/Branch1/Channel0/DIMM1           2
                                                              Channel0/DIMM 1/Branch 1
                                                                  CMP0/Branch1/Channel0/DIMM0           1                       SECOND
                                                                                                                          Install ALL DIMMs in




                                                 UltraSPARC
                                                              Channel0/DIMM 1/Branch 1
                                                                  CMP0/Branch0/Channel0/DIMM0           1                         Group 2




                                                  T2 Plus 0
                                                              Channel0/DIMM 1/Branch 1
                                                                  CMP0/Branch0/Channel0/DIMM1           2                   12 DIMM Config
                                                              Channel0/DIMM 1/Branch 1
                                                                  CMP0/Branch0/Channel1/DIMM1           2
                                                              Channel0/DIMM 1/Branch 1
                                                                  CMP0/Branch0/Channel1/DIMM0           1
                                                                                                                                  FIRST
                                                                                                                          Install ALL DIMMs in
                                                                                                                                  Group 1
                                                                                                                            8 DIMM Minimum
                                                 UltraSPARC

                                                              Channel0/DIMM 1/Branch 1
                                                                  CMP1/Branch1/Channel1/DIMM0           1                        Config
                                                  T2 Plus 1



                                                              Channel0/DIMM 1/Branch 1
                                                                  CMP1/Branch1/Channel1/DIMM1           3

                                                              Channel0/DIMM 1/Branch 1
                                                                  CMP1/Branch1/Channel0/DIMM1           3
                                                              Channel0/DIMM 1/Branch 1                  1                         THIRD
                                                                  CMP1/Branch1/Channel0/DIMM0                             Install ALL DIMMs in
                                                              Channel0/DIMM 1/Branch 1
                                                                  CMP1/Branch0/Channel0/DIMM0           1                         Group 3
                                                              Channel0/DIMM 1/Branch 1
                                                                  CMP1/Branch0/Channel0/DIMM1           3                   16 DIMM Config

                                                               Channel0/DIMM 1/Branch 1
                                                                   CMP1/Branch0/Channel1/DIMM1           3
                                                               Channel0/DIMM 1/Branch 1
                                                                   CMP1/Branch0/Channel1/DIMM0           1


          At RR, Supported configs will be ...                    All DIMMs MUST be the same Size i.e 1GB, 2GB, 4GB, no mixing
     Fully Populate Group 1 and 2 (8 DIMMS)                          All DIMMs in a Branch must be the same Sun Part Number
   Fully Populate Groups 1, 2 and 3 (16 DIMMS)                          Unused DIMM locations must be occupied with DIMM Fillers
                                                 Sun Internal and Approved Partners Only                                                         23
Mezzanine Memory Physical Layout
Chassis                                                                                                                                     Chassis
Front                                                                                                                                       Rear
                                                                     Channel0/DIMM 1/Branch 1
                                                                        CMP0/MR0/BR1/CH1/DIMM3                 4
                                                                     Channel0/DIMM 1/Branch 1
                                                                        CMP0/MR0/BR1/CH1/DIMM2
                                                                                 3                             4

                                                                         CMP0/MR0/BR1/CH0/DIMM2                4
                                                                         CMP0/MR0/BR1/CH0/DIMM3                4                       FOURTH
                                                                                                                                 Install ALL DIMMs in
                                                                         CMP0/MR0/BR0/CH0/DIMM3                4                         Group 4
                                                                         CMP0/MR0/BR0/CH0/DIMM2                4                   24 DIMM Config

                                                                         CMP0/MR0/BR0/CH1/DIMM2                4
                                                                         CMP0/MR0/BR1/CH1/DIMM3                4




                                                                         CMP1/MR1/BR1/CH1/DIMM3                5
                                                                         CMP1/MR1/BR1/CH1/DIMM2                5

                                                                         CMP1/MR1/BR1/CH0/DIMM2                5
                                                                                                               5                         FIFTH
                                                                         CMP1/MR1/BR1/CH0/DIMM3                                  Install ALL DIMMs in
                                                                         CMP1/MR1/BR0/CH0/DIMM3                5                         Group 5
                                                                         CMP1/MR1/BR0/CH0/DIMM2                5                   32 DIMM Config

                                                                        CMP1/MR1/BR0/CH1/DIMM2                 5
                                                                     Channel0/DIMM 1/Branch 1
                                                                        CMP1/MR1/BR0/CH1/DIMM3                 5


           At RR, Supported configs will be ...                         All DIMMs MUST be the same Size i.e 1GB, 2GB, 4GB, no mixing
   Fully Populate Groups 1, 2, 3 , 4 and 5 (32 DIMMS)                      All DIMMs in a Branch must be the same Sun Part Number
                                                                               Unused DIMM locations must be occupied with DIMM Fillers
                                                        Sun Internal and Approved Partners Only                                                         24
Memory Configuration Rules
• Populate at least 4 DIMMS at a time
• Populate by complete group only (set 1, 2, 3, 4, 5)
    > Groups may be 4 or 8 DIMMs, check service labels on lid
• Ensure proper installation of Airflow Guides
    > All Configs require DIMM fillers for correct air-flow
    > 1RU has no Airflow Guide
    > 2RU has two configurations
        – No Mezzanine
              – Install Lower Air Guide
        – With Mezzanine
              – Install Lower PDB Guide and Mezzanine Guide

•   All DIMMS must be the same size(i.e all 1GB, 2GB or 4GB, no mixing)
•   In a Group all DIMMS must have the same SUN Part No.
•   No clocking down of memory in any config.
•   8GB DIMMs will be qualified/evaluated after RR
                                          Sun Internal and Approved Partners Only   25
Network Ports and Options

                                   XAUI 0                                                 XAUI 1




 Device         NET 0           NET 1           NET 2           NET 3           XAUI 0          XAUI 1
 Driver         nxge0           nxge1           nxge2           nxge3           nxge0*          nxge1*
 PCI Device PCI@300/0/8/0,0 PCI@300/0/8/0,1 PCI@300/0/8/0,2 PCI@300/0/8/0,3 PCI@300/0/8/0,0 PCI@300/0/8/0,1


                                                          NOTES
                          All Ethernet ports provided by a single Neptune Chip on the motherboard
               NET 0 and NET 1 are disabled by XAUI cards if installed to take advantage of 10GbE networking
                               * If a XAUI card is installed, the matching RJ-45 port is disabled
                               XAUI cards take one of three current Fibre 10GbE transceivers
                                Short Reach(SR), Long Reach(LR) and Long Reach Multimode(LRM)
                                  Copper versions of the XAUI card are expected Post-RR
             XAUI Cards consume the same physical space in the chassis as a PCI card, so are mutually exclusive
                                          with PCI cards in the same location


                                                    Sun Internal and Approved Partners Only                       26
10GbE XAUI Option Cards
• Interface to the Neptune chip to upgrade two of its ports to 10GbE
• Cards each consume a PCIe slot if installed
• Attach to dedicated XAUI sockets on special risers
• 10Gbe XAUI Card
             – SESY7XA1Z
   > Requires Fibre Tranceivers
       – 10GbE Short Reach(SR)
             – SESY7XT1Z
       – 10GbE Long Reach (LR)
             – SESY7XT2Z
       – 10GbE Long Reach multimode (LRM)
             – part No. TBD

• Copper connector XAUI versions to follow post-RR


                                Sun Internal and Approved Partners Only   27
PCI Riser Cards
• Various Riser Cards are used
• Risers should not be moved between slots
• All slots accommodate low Profile PCI-Express cards
• T5140 – 25 Watts per card, 75 Watts Max (3 Slots)
• T5240 – 25 Watts per card, 102 Watts Max (6 Slots)

   > Riser Card Mechanical and Electrical widths for T5140 and T5240


            T5140                Slot 0                                    Slot 1                  Slot 2
            Only Slot     x8/XAUI(m)             x8(e) x8/XAUI(m)                   x8(e) x16(m)            x8(e)


            T5240                Slot 1                                    Slot 1                  Slot 2
           Top Slot       x8(m)                  x8(e) x8(m)                        x8(e) x8(m)             x8(e)
          Bottom Slot     x8/XAUI(m)             x8(e) x8/XAUI(m)                   x8(e) x16(m)            x8(e)


                                 Sun Internal and Approved Partners Only                                            28
Disk Cage
• Disk chassis is a FRU
       – 4 screws and disconnect cables
• Contains DVD-RW/Dual USB module as a
  sub-FRU/CRU
       – Standard in all default configs
       – remove disk 3/7 to access release latch, pre-RR
• Non-DVD module available as X-Option
      – Still provides Dual USB ports                                           Remove Disk and locate latch
                                                                                      beneath DVD
                                                                                 Press up and pull DVD out
• T5140 will be available with only a 4
  disk chassis (8 disk may be post RR)
  > Only uses one of the x4 SAS links
• T5240 will be available with 8 or 16 disk chassis
  > 16 Disk systems requires High-Line Power (220VAC)




                                      Sun Internal and Approved Partners Only                                  29
Disk Drives
• Disk drives are all 2.5” form factor
• Chassis support both SAS and SATA (post-RR)
• SAS Drives
      – 73GB @ 10K RPM
      – 146GB @ 10K RPM
      – 73GB @ 15K RPM                                                                            Improved
                                                                                                Airflow above
                                                                                                 and below
      – 146GB @ 15K RPM (post-RR)                                                                    disks


• SATA Drives
      – 300GB @ 5400 RPM (H2CY08)
      – 500GB @ 7200 RPM (end CY08)
                                                                                   Disk LED's
• New mounting bracket “Marlin”                                             Ready to
                                                                            Remove
  > Allows better cooling in denser chassis                                    Fault
                                                                              Status
• Same disks as T5x20 systems



                                         Sun Internal and Approved Partners Only                                30
Disk Controller Options
• T5x40 has embedded LSI1068E on the motherboard
      – JBOD up to 8 disks
      – Controls internal disks only
      – RAID 0 (striping) and RAID 1(mirroring), using 'radictl'
      – Hot-plug supported
      – Hot-swap in non-RAID configs is done with 'cfgadm'
• Optional Extended RAID functionality cards
  > SPARC Drivers are available, SAS cables are being produced now
  > SGXPCIESAS-R-INT-Z
       – 8 port SAS RAID 0,1,1E,5,5EE,6,10,50,60 (depending on number of disks available)
       – Adaptec Card and Firmware with Intel SunRiseLake chipset
       – Battery Backed Write Cache (BBWC) of 256MB
       – BBWC battery at least 72 hours (much longer when new/fully charged)
       – Only for internal disks, replaces cables to route to standard disk chassis
  > SGXPCIESAS-R-EXT-Z
       – External port version, for external disk arrays only (no internal ports)
  > Not available for T5440 due to chassis design and only 4 disk capacity
                                      Sun Internal and Approved Partners Only               31
Fans and Cooling
• T5140                                                    Unused Fan slots can be populated, but not recommended, fans will
                                                                run and wear, so not a great way of keeping spares....
  > Requires 6 Fan modules
      – Main System Cooling




                                                                                                    FBD1

                                                                                                           FBD0
                                                                            PSU's




                                                                                                    FM3

                                                                                                           FM3
                                                                                                           FM3
            – FANBD0/FM0




                                                                                                                      Disk Chassis
                                                                                                                      Disk Chassis
                                                                                                    FBD1
            – FANBD0/FM1




                                                                                                           FBD0
                                                                                                    FM2

                                                                                                           FM2
                                                                                                           FM2
            – FANBD0/FM2
            – FANBD1/FM0




                                                                                                    FBD1

                                                                                                           FBD0
                                                                         Motherboard




                                                                                                    FM1

                                                                                                           FM1
                                                                                                           FM1
            – FANBD1/FM1
            – FANBD1/FM2




                                                                                                    FBD1

                                                                                                           FBD0
                                                                                                    FM0

                                                                                                           FM0
                                                                                                           FM0
      – No Modules in FM3
• T5240                                                    Back                                                                      Front
  > Requires 5 Fan Modules
      – Main system Cooling                                                 PSU's




                                                                                                   FBD1

                                                                                                           FBD0
                                                                                                   FM2

                                                                                                           FM2
                                                                                                   FM2

                                                                                                           FM2
            – FANBD0/FM0




                                                                                                                      Disk Chassis
                                                                                                                      Disk Chassis
            – FANBD0/FM1




                                                                                                   FBD1

                                                                                                           FBD0
                                                                                                   FM1

                                                                                                           FM1
                                                                                                   FM1

                                                                                                           FM1
            – FANBD0/FM2
                                                                         Motherboard
            – FANBD1/FM0
            – FANBD1/FM1




                                                                                                    FBD1

                                                                                                           FBD0
                                                                                                    FM0

                                                                                                           FM0
                                                                                                           FM0
      – No Modules in FANBD1/FM2
                               Sun Internal and Approved Partners Only                                                                       32
Fans modules and boards
• Fans are speed controlled by the Service Processor
• Each fan has an Amber FAULT LED
      – if lit the fan module is faulty
• 1RU modules
      – 2 Fans at 15K RPM Max.
                                                                                 Fan Fault
• 2RU modules                                                                   Amber LED

      – 2 Fans at 12K RPM Max                                                  Lit if fan faulty


• Monitored through ILOM/IPMI/Web




                                                            Vibration
                                                            Absorbing
                                                             Silicon
                                                            Dampers




                                     Sun Internal and Approved Partners Only                       33
Power Supplies
•   PSU's are high efficiency
•   Output 12V (and 3.3v standby)                                                        PSU LED's
•   Most DC-DC conversion done in MBD                                                            Ready to
                                                                                                 Remove
                                                                                         Fault
•   Shared with Doradi/o, Tucani/a                                                 AC
                                                                               Present

•   Integrated Fan
•   T5140
    > Side-by-Side
    > AC 720Watts
• T5240
    >   Vertically Stacked
    >   1100Watts
    >   DC 1200 Watts option coming post-RR
    >   DC or AC, no sharing
    >   BEWARE...
         – Same form factor as SunFire X4200 PSU's ... DO NOT MIX
         – 1.4Ghz and 16 Disk configs require 220VAC (called “High Line Power”)
                                     Sun Internal and Approved Partners Only                                34
Rack Mounting Options
• Two Rack mounting options are available..
• Standard Rack Mount (4 post)SESY9RK1Z
  > Standard configs contain this kit
     – ATO : SESY9RK1Z, X-ATO : SESY9RK1Z
• Tool-less Rack Kit (4 post)
  > Optional kit, purchased seperately
  > Snaps into most 3rd party Racks
  > Requires no tools to fit or remove
     – ATO : SESY9RK2Z, X-ATO : SESX9RK2Z




                         Sun Internal and Approved Partners Only   35
Solaris for Sun SPARC Enterprise T5x40
• T5x40 servers will require Solaris10 8/07 (update 4) with
  patches
  > A Patch CD is supplied in the box
     – Mandatory patches = 127111-08,126434-05,125416-05
     – Available patches = 124235-02, 125369-13,125476-02,127111-07
     – Likely to be out of date, so customers should check SunSolve...
• This incorporates several specific UltraSPARC T2/T2 Plus
  optimizations and for CMT servers in general
• Also includes some specific T5x40 optimisations
  >   UltraSPARC T2 Plus MPO optimisations
  >   nxge driver tweaks for 10GbE devices
  >   MMU DMA relaxed scheduling
  >   LDOMs pre-install upgrade to version 1.0.2 (US T2 Plus support)
                             Sun Internal and Approved Partners Only     36
Solaris FMA
•   Now aware of CPU Core offlining
•   PCIe Fabric diagnostics improved
•   Crypto Unit offlining
•   Neptune awareness (though XAUI's not diagnosed)
•   POST memory CE tolerance improved
•   FRU identity info improved in fault reports (part/ser #)
•   Diagnostic Engines (DE)
        – Existing DE have been extended for T5x40
        – New Eversholt DE used for HostBridge, PCIe diagnostics
• Limitations...
              –   Can't isolate Uncorrectable Errors to a single DIMM
              –   PCIe riser cards not in topology
              –   XAUI card and XFP not in the topology
              –   SouthBridge chip is not diagnosed at this time (DVD, USB,...)
              –   IO Expansion box is not diagnosed via FMA
                                      Sun Internal and Approved Partners Only     37
ILOM Features at a Glance
•   Hardware Control, Inventory, Monitoring
•   Host Configuration and Administration
•   SP Configuration and Administration
•   Logging, Auditing and Alerting
•   Authentication :
       – LDAP, RADIUS, Active Directory, Local Users
• Services :
       – SSH, HTTP(S), NTP, Syslog, SMTP
• Out-of-Band
       – Via Serial port, or dedicated Ethernet port
• In-Band
       – Via Host OS, firmware upload, Explorer, Syslog

                                   Sun Internal and Approved Partners Only   38
ILOM – Industry Standard Manageability
 • ILOM enables Sun systems to be easily integrated into third
   party management infrastructures
 • Key functionality
   >   IPMI 2.0
   >   SNMP V1, V2c, V3
   >   SSH 2.0
   >   LDAP, RADIUS & MS Active Directory authentication
   >   Browser UI, SMASH DMTF CLP + ALOM style CLI
 • NOTE : No RKVMS functionality like Galaxy ILOM
    > No Java plugin required
 • Browsers tested include, these base versions an later
   releases
       – Mozilla 1.7 on Solaris 10, IE 6.0 on W2K Server, Firefox
         1.0 and 1.5 on W2K server
                               Sun Internal and Approved Partners Only   39
ILOM – Industry Standard Manageability

 • Identical to ILOM 2.0 for T5x20
 • Default user is 'root' with password 'changeme'
    > Use for ILOM WEB GUI access and SSH access and IPMI
 • The ALOM 'admin' user is not defined by default, create this
   user with an ALOM CLI
 • Lost 'root' password and ILOM config is reset using jumpers
    > T5140/T5240 - Motherboard Jumper J10401 (short pins 1-2)
 • Note... 'sunservice' user shares the password of the 'root'
   user           ONLY FOR SERVICE ACCESS*
 • Passwords must be 8 to 16 chars (used to be max 8)
 • Max of 10 users allowed (used to be 16)

                           Sun Internal and Approved Partners Only   40
ILOM Common Tasks
• Setting up an ALOM 'admin' user from the ILOM CLI
  >   SUNSP00144F4641BD login: root
      Password: changeme
      Waiting for daemons to initialize...
      Daemons ready
      Sun(TM) Integrated Lights Out Manager
      Version 2.0.4.0
      Copyright 2007 Sun Microsystems, Inc. All rights reserved.
      Use is subject to license terms.
      Warning: password is set to factory default.
      ->create /SP/users/admin role=Administrator cli_mode=alom
      Creating user...
      Enter new password: ********
      Enter new password again: ********
      Created /SP/users/admin2
      -> exit
      SUNSP00144F4641BD login: admin
      Password: ********
      Waiting for daemons to initialize...
      Daemons ready
      Sun(TM) Integrated Lights Out Manager
      Version 2.0.4.0
      Copyright 2007 Sun Microsystems, Inc. All rights reserved.
      Use is subject to license terms.
      sc>




                                         Sun Internal and Approved Partners Only   41
ILOM Common Tasks
• Setting up ILOM IP configuration from the ILOM CLI
  >   SUNSP00144F4641BD login: root
      Password: changeme
      Waiting for daemons to initialize...
      Daemons ready
      Sun(TM) Integrated Lights Out Manager
      Version 2.0.4.0
      Copyright 2007 Sun Microsystems, Inc. All rights reserved.
      Use is subject to license terms.
      Warning: password is set to factory default.
      -> set /SP/network state=enabled
      Set ’state’ to ’enabled’
      -> set /SP/network pendingipaddress=10.8.31.163
      Set ’pendingipaddress’ to ’10.8.31.163’
      -> set /SP/network pendingipdiscovery=static
      Set ’pendingipdiscovery’ to ’static’
      -> set /SP/network pendingipnetmask=255.255.252.0
      Set ’pendingipnetmask’ to ’255.255.252.0’
      -> set /SP/network pendingipgateway=10.8.31.248                                Static IP
      Set ’pendingipgateway’ to ’10.8.31.248’                                      configuration
      -> set /SP/network commitpending=true
      Set ’commitpending’ to ’true’
      ->

      -> set/SP/pendingipdiscovery=dhcp
      Set ’pendingipdiscovery’ to ’dhcp’
      -> set /SP/network commitpending=true
      Set ’commitpending’ to ’true’
      ->
                                                                                   Dynamic IP
                                                                                     (DHCP)
                                                                                   configuration



                                         Sun Internal and Approved Partners Only                   42
ILOM IPMI functionality
• IPMI is a widely used management protocol for x86 servers
• ... But its new for SPARC boxes...
• Download the required tools from
  > The Solaris Supplemental CD (an older binary package)
  > Latest is available at http://ipmitool.sourceforge.net
     – Binary packages (usually older versions) are available for Solaris x86 and SPARC,
       as well as Linux, Windows, Mac...etc
  > There is a Blueprint available from Sun also (mainly x64 centric, but applies to SPARC
    now too)
            – http://www.sun.com/blueprints/0107/820-1011.pdf


       -bash-ventus2$ /opt/ipmitool/bin/ipmitool     -U root -P changeme -H 10.10.10.10 sdr
       /MB/V_+1V0_VDD   | 1.01 Volts        | ok
       /MB/V_+3V3_STBY | 3.36 Volts         | ok                                                             Get the Sensor
       /MB/V_+3V3_MAIN | 3.36 Volts         | ok                                                                  Data
       /MB/V_+5V0_VCC   | 4.97 Volts        | ok                                                              Repository
       /MB/V_+12V0_MAIN | 12.16 Volts       | ok
       ..
       ..
       -bash-ventus2$ /opt/ipmitool/bin/ipmitool     -U root -P changeme -H 10.10.10.10 sunoem sbled set
       /SYS/LOCATE on
       /SYS/LOCATE      | ON                                                                               Set the System
       -bash-ventus2$                                                                                       Locator LED
                                                                                                               flashing

                                          Sun Internal and Approved Partners Only                                      43
ILOM Common Tasks
• Logging into the ILOM Web GUI
                                                               •   Point Web Browser at the IP address of
                                                                   the ILOM
                                                                    > Will automatically redirect to a
                                                                        secure HTTPS port
                                                                    > Best to disable any Web Proxies for
                                                                        best performance
                                                                    > Make sure port 80, 443 are open on
                                                                        any firewall
                                                               •   Log in as any defined user, default
                                                                   Administration user is 'root'




                     Sun Internal and Approved Partners Only                                                44
ILOM/ALOM Common Tasks
• A Tour of the ILOM Web GUI                                   •   GUI provides ways to set up IP address
                                                                   configurations for ILOM
                                                               •   Configure additional ILOM/ALOM users
                                                               •   Access Sensor Readings
                                                               •   Control System configurations
                                                               •   Carry out firmware updates.
                                                               •   etc....




                     Sun Internal and Approved Partners Only                                                45
ALOM 2.0 vs. 1.4 CLI Differences
• Default CLI appearance is ILOM
      – User is 'root'
      – Must create an 'admin' Administrator user with the ALOM CLI
• Flashupdate in new ALOM expects a TFTP server not an FTP server
• ALOM IP address changes now active only after running ...
      – 'setsc netsc_commit true             '
      – Previously changes were active only after SC reset
      – DHCP is enabled by default
• View firmware versions with
      – 'showhost version        '                      sc> showhost version
                                                         Sun System Firmware 7.0.0_build_13 2007/08/10 23:44


• Only Admin and Operator roles                         Host flash versions:
                                                           Hypervisor 1.5.0.build_13**PROTOTYPE** 2007/08/10 22:54
                                                           OBP 4.27.0.build_04***PROTOTYPE BUILD*** 2007/08/10 13:25

  are defined                                              Sun Fire[TM] Huron POST 4.27.0.build_04***PROTOTYPE BUILD***
                                                        2007/08/10 13:51




                             Sun Internal and Approved Partners Only                                                      46
ALOM backward Compatibilty CLI
• Uses ALOM-CMT 1.2 for a base feature set
• Includes ALOM-CMT 1.4 features...
  >   break -d
  >   Host Watchdog Timer
  >   Bootmode LDOMs awareness
  >   Forward SP events to Hot/Solaris syslog via inband channel




                           Sun Internal and Approved Partners Only   47
Logical Domains 1.0.2 Features
Release in Q1CY08 aligned with UltraSPARC T2 Plus launch
• UltraSPARC T2 Plus Platform Support
  > 128 domains supported at RR
     – 256 domains work on T5440, may be qualified later, requires Solaris fixes
• Feature Set very similar to 1.0.1
• I/O domain can reboot while the other domains keep running
  > Dependant domains would wait for IO transactions to complete
• LDoms SNMP MIB
  > Modeled after industry standard DMTF CIM (Common Information Model)
  > Running on control domain to enable remote SNMP monitoring
• Domain minimization support
  > Minimal/reduced Solaris installation
  > Base minimal packages plus optional ones for guest, control, I/O or service
    domains
                              Sun Internal and Approved Partners Only              48
Logical Domains 1.0.2 Requirements
 • Solaris 10 08/07 (update 4) and required patches
 • Systems firmware version
      – T5x40 Firmware 7.1.0 = SP FW 2.0.4.20+
      – T5x20/SB6320 Firmware 7.0.4+ = SP FW 2.0.4.0+
      – T2000/T1000/T6300/Pelton Firmware 6.5.x
 • SUNWldm.v LDOMs Manager Package
      – Version 1.0.2




                           Sun Internal and Approved Partners Only   49
CRU/FRU List - T5140
• Lots shared with other Jake and Elwood systems
                     Item                                            Description                                   FRU/CRU
    Disk Backplane 4 drive                             Disk Backplane to support 4 Drives only                       FRU
    Disk Backplane 8 drive                          Disk Backplane to support 8 Drives (post -RR)                    FRU
    Fan Module 1U                                      Dual Fan module, 4 populated in system                        CRU
    Fan Board 1U                           Fan connector board to accommodate Fan Modules, 2 per system              FRU
    DVD Assembly                                      DVD Assembly including front USB board                         FRU
    Paddle board 1U                            Conection between PDB, fan boards and Disk Backplane                  FRU
    PDB 1U                                 Power distribution board, contains master chassis serial number           FRU
    PSU 1U                                                    Power supply (720 Watts)                               CRU
    X8 &XAUI, 1U PCIe Riser                    PCI Riser assembly for left and centre motherboard slots              CRU
    x16 1U PCIe Riser                                    PCI Riser for right motherboard slot                        CRU
    Rack mount kit (requires tools)                                 Rack mount kit                                   CRU
    Rack Mount Kit (tooless)                       Rack mount kit, no tools required for installation                CRU
    CMA                                                        Cable management arm                                  CRU
    Bus Bars                                       Power Bus Bars between PDB and Motherboard                        FRU
    PDB to MB Ribbon Cable               Ribbon cable for control connections between PDB abd Motherboard            FRU
    Light pipe kit                               Light pipe assemblies for left and right of disk cage               FRU
    Motherboard assembly                    Motherboard assembly, part no varies depending on Core count             FRU
    DIMMs                                     FBDIMMs (three different part numbers for 1GB, 2GB, 4GB)               CRU
    XAUI board optical/copper                  XAUI Adapter card (two different parts for copper/optical)            CRU
    XFP module                        XFP GBIC module for use in XAUI cards (three different parts SR, HR, HRMM)     CRU
    Battery                                        Battery backup for NVRAM of Service Processor                     CRU
    HDD 73GB/146GB                            SAS Hard Disk drive, different part numbers for capacities             CRU
    System Configurations PROM                               System Configuration PROM                               FRU
    Maramba Cable Kit                                               SAS Cable kit                                    FRU




                                                    Sun Internal and Approved Partners Only                                  50
CRU/FRU List - T5240
• Lots shared with other Jake and Elwood systems
                     Item                                            Description                                  FRU/CRU
   Disk Backplane 16 drive                            Disk Backplane to support 16 Drives only                      FRU
   Disk Backplane 8 drive                             Disk Backplane to support 8 Drives only                       FRU
   Fan Module 2U                                      Dual Fan module, 3 populated in system                        CRU
   Fan Board 2U                           Fan connector board to accommodate Fan Modules, 2 per system              FRU
   DVD Assembly                                      DVD Assembly including front USB board                         FRU
   Paddle board 2U                           Connection between PDB, fan boards and Disk Backplane                  FRU
   PDB 2U                                 Power distribution board, contains master chassis serial number           FRU
   PSU 2U                                                    Power supply (1100 Watts)                              CRU
   X8,X8, XAUI, 2U PCIe Riser                 PCI Riser assembly for left and centre motherboard slots              CRU
   X8, x16 2U PCIe Riser                                 PCI Riser for right motherboard slot                       CRU
   Rack mount kit (requires tools)                                  Rack mount kit                                  CRU
   Rack Mount Kit (tooless)                       Rack mount kit, no tools required for installation                CRU
   CMA                                                         Cable management arm                                 CRU
   Bus Bars                                       Power Bus Bars between PDB and Motherboard                        FRU
   PDB to MB Ribbon Cable               Ribbon cable for control connections between PDB abd Motherboard            FRU
   Light pipe kit                               Light pipe assemblies for left and right of disk cage               FRU
   Motherboard assembly                   Motherboard assembly, part no varies depending on Core count              FRU
   DIMMs                                     FBDIMMs (three different part numbers for 1GB, 2GB, 4GB)               CRU
   XAUI board optical/copper                  XAUI Adapter card (two different parts for copper/optical)            CRU
   XFP module                        XFP GBIC module for use in XAUI cards (three different parts SR, HR, HRMM)     CRU
   Battery                                        Battery backup for NVRAM of Service Processor                     CRU
   HDD 73GB/146GB                            SAS Hard Disk drive, different part numbers for capacities             CRU
   System Configurations PROM                               System Configuration PROM                               FRU
   Maramba Cable Kit                                                SAS Cable kit                                   FRU




                                                    Sun Internal and Approved Partners Only                                 51
Option Parts List for T5140/T5240
 Part Number   Option Description                                            Available
  SECY9PS41Z   AC PSU 1RU (720 Watts)                                        RR
  SEDY9PS51Z   AC PSU 2RU (1100 Watts)                                       RR
  -            DC PSU 2RU (1200Watts)                                        post-RR
  SESY2A1Z     2GB Memory (2x1GB)                                            RR
  SESY2B1Z     4GB memory (2x2GB)                                            RR
  SESY2C1Z     8GB Memory (2x4GB)                                            RR
  SESY9FF1Z    FB-DIMM Filler panel                                          RR
  SEUY2MM1Z    Memory Mezzanine Assembly 2U only                             RR
  SEU9AD1Z     Memory Mezzanine Air Duct                                     RR
  SETY9BA1Z    4 Disk Backplane for 1U                                       RR
  SETY9BB1Z    8 Disk Backplane for 1U                                       post-RR
  SEUY9BB1Z    8 Disk Backplane for 2U                                       RR
  SEUY9BC1Z    16 Disk Backplane for 2U (High Line only (220VAC)             RR
  SESY3A11Z    73GB, 10KRpm 2.5” SAS Drive                                   RR
  SESY3C11Z    146GB, 10KRpm 2.5” SAS Drive                                  RR
  SESX3A21Z    73GB, 15KRpm, 2.5” SAS Drive                                  RR
  -            SATA Drives (300,500GB)                                       post-RR
  SESY9MF1Z    HDD Filler Panel                                              RR
  SESY9DV1Z    DVD, 8X RW, Slot Load                                         RR
  SESY9RK1Z    Slide Rail Kit, requires screwdriver (1RU and 2RU)            RR
  SESY9RK2Z    Slide Rail Kit, Tool-less (1RU and 2RU)                       RR




                                   Sun Internal and Approved Partners Only               52
Option Parts List for T5140/T5240 (cont..)
         Part Number                         Option Description                         Avialable   Max no.(1RU/2RU)
SG-PCIE1FC-QF4                        Qlogic, 4Gb, PCI-E Single Port                       RR             3/6
SG-PCIE2FC-QF4                         Qlogic, 4Gb, PCI-E Dual Port                        RR             3/6
SG-PCIE1FC-EM4                       Emulex, 4Gb, PCI-E Single Port                        RR             3/6
SG-PCIE2FC-EM4                         Emulex, 4Gb, PCI-E Dual Port                        RR             3/6
SG-PCIE2SCSI-U320Z                      U320 SCSI, PCI-E Dual Port                         RR             3/6
SG-PCIE8SAS-E-Z                              SAS, 8 Port, PCI-E                            RR             3/6
SGCPCIESAS-R-INT-Z          SAS, 8 Port, RAID, PCI-E, External Drive Controller            RR             1/1
SGCPCIESAS-R-EXT-Z          SAS, 8 Port, RAID, PCI-E, External Drive Controller            RR             1/1
SECX9SA1Z                                 Cable X-option for T5140                         RR             1/1
SECX9SA2Z                                 Cable X-option for T5240                         RR             1/1
7281A-2                      Northstar Dual port GigE MMF Low profile PCI-E                RR             3/6
7280A-2                      Northstar Dual port GigE UTP Low profile PCI-E                RR             3/6
1236A-Z                            Infiniband HBA, Dual 4x ports, PCI-E                    RR             3/6
4447A-X                      Atlas Quad Port, GigE Copper, PCI-E (up to 3/6)               RR             3/3
X1027A-Z                               Atlas Dual Port, 10GigE, PCI-E                      RR             3/3
X5558A                            Tranceiver 10GE SR XFP (XAUI/Atlas)                      RR               -
X5560A-Z                           Tranceiver 10GE LR XFP (XAUI/Atlas)                     RR               -
X3000A                              XVR-300, PCI-E x8 Graphics cards                      TBD             1/1
X4240A                 XVR-300, PCI-E x16 Graphics cards, requires 605-4668-04 cable      TBD             1/1
SESY7XA1Z                                     10GbE XAUI card                              RR             2/2
TBD                                   10GbE XAUI Copper 10g Base-T                        TBD             2/2
X6000A                                  Sun Crypto Accelerator 6000                        RR             1/ 2




                                              Sun Internal and Approved Partners Only                                  53
Sun sparc enterprise t5140 and t5240 servers technical presentation
Sun sparc enterprise t5140 and t5240 servers technical presentation
Sun sparc enterprise t5140 and t5240 servers technical presentation
Sun sparc enterprise t5140 and t5240 servers technical presentation
Sun sparc enterprise t5140 and t5240 servers technical presentation
Sun sparc enterprise t5140 and t5240 servers technical presentation
Sun sparc enterprise t5140 and t5240 servers technical presentation
Sun sparc enterprise t5140 and t5240 servers technical presentation
Sun sparc enterprise t5140 and t5240 servers technical presentation
Sun sparc enterprise t5140 and t5240 servers technical presentation
Sun sparc enterprise t5140 and t5240 servers technical presentation
Sun sparc enterprise t5140 and t5240 servers technical presentation

Contenu connexe

Tendances

“見てわかる” ファイバーチャネルSAN基礎講座(第3弾)~間違わない!FC SAN導入のヒントとコツ~
“見てわかる” ファイバーチャネルSAN基礎講座(第3弾)~間違わない!FC SAN導入のヒントとコツ~“見てわかる” ファイバーチャネルSAN基礎講座(第3弾)~間違わない!FC SAN導入のヒントとコツ~
“見てわかる” ファイバーチャネルSAN基礎講座(第3弾)~間違わない!FC SAN導入のヒントとコツ~Brocade
 
“見てわかる” ファイバーチャネルSAN基礎講座(第2弾)~FC SAN設計における勘所とは?~
“見てわかる” ファイバーチャネルSAN基礎講座(第2弾)~FC SAN設計における勘所とは?~“見てわかる” ファイバーチャネルSAN基礎講座(第2弾)~FC SAN設計における勘所とは?~
“見てわかる” ファイバーチャネルSAN基礎講座(第2弾)~FC SAN設計における勘所とは?~Brocade
 
ここまできた! ”第6世代”ファイバーチャネルがもたらす ストレージ・ネットワークの 新たな可能性とは?
ここまできた! ”第6世代”ファイバーチャネルがもたらす ストレージ・ネットワークの 新たな可能性とは?ここまできた! ”第6世代”ファイバーチャネルがもたらす ストレージ・ネットワークの 新たな可能性とは?
ここまできた! ”第6世代”ファイバーチャネルがもたらす ストレージ・ネットワークの 新たな可能性とは?Brocade
 
Brocade SAN 製品概要
Brocade SAN 製品概要Brocade SAN 製品概要
Brocade SAN 製品概要Brocade
 
Tipos de Cablagens de Rede
Tipos de Cablagens de RedeTipos de Cablagens de Rede
Tipos de Cablagens de Redescb.carlos
 
JunOS Jumstart 01 - JunOS Overview.ppt
JunOS Jumstart 01 - JunOS Overview.pptJunOS Jumstart 01 - JunOS Overview.ppt
JunOS Jumstart 01 - JunOS Overview.pptLucTieuPhung1
 
ブロケード FC ファブリックスイッチ オペレーション講座(後編)
ブロケード FC  ファブリックスイッチ オペレーション講座(後編)ブロケード FC  ファブリックスイッチ オペレーション講座(後編)
ブロケード FC ファブリックスイッチ オペレーション講座(後編)Brocade
 
Vlan lab
Vlan labVlan lab
Vlan labtmim8
 
“見てわかる” ファイバーチャネルSAN基礎講座(第5弾)~さあ、いよいよ、運用です!~
“見てわかる” ファイバーチャネルSAN基礎講座(第5弾)~さあ、いよいよ、運用です!~“見てわかる” ファイバーチャネルSAN基礎講座(第5弾)~さあ、いよいよ、運用です!~
“見てわかる” ファイバーチャネルSAN基礎講座(第5弾)~さあ、いよいよ、運用です!~Brocade
 
CCNAv5 - S2: Chapter5 Inter Vlan Routing
CCNAv5 - S2: Chapter5 Inter Vlan RoutingCCNAv5 - S2: Chapter5 Inter Vlan Routing
CCNAv5 - S2: Chapter5 Inter Vlan RoutingVuz Dở Hơi
 
OpenSPARC T1 Processor
OpenSPARC T1 ProcessorOpenSPARC T1 Processor
OpenSPARC T1 ProcessorDVClub
 
DOCSIS 3.0 SCTE Piedmont Chapter January 18th
DOCSIS 3.0 SCTE Piedmont Chapter January 18thDOCSIS 3.0 SCTE Piedmont Chapter January 18th
DOCSIS 3.0 SCTE Piedmont Chapter January 18thThe Volpe Firm, Inc.
 
Cisco-Press-CCNP-and-CCIE-Enterprise-Core-ENCOR-350-401-Official-Cert-Guide.pdf
Cisco-Press-CCNP-and-CCIE-Enterprise-Core-ENCOR-350-401-Official-Cert-Guide.pdfCisco-Press-CCNP-and-CCIE-Enterprise-Core-ENCOR-350-401-Official-Cert-Guide.pdf
Cisco-Press-CCNP-and-CCIE-Enterprise-Core-ENCOR-350-401-Official-Cert-Guide.pdfLeeRonald2
 
Архитектура маршрутизатора ASR1k и его применение в сетях операторов связи.
Архитектура маршрутизатора ASR1k и его применение в сетях операторов связи. Архитектура маршрутизатора ASR1k и его применение в сетях операторов связи.
Архитектура маршрутизатора ASR1k и его применение в сетях операторов связи. Cisco Russia
 
Introduction to Wi-Fi Direct
Introduction to Wi-Fi DirectIntroduction to Wi-Fi Direct
Introduction to Wi-Fi DirectWei-Tsung Su
 
TV y video multicast en redes LAN. Trucos y recomendaciones
TV y video multicast en redes LAN. Trucos y recomendacionesTV y video multicast en redes LAN. Trucos y recomendaciones
TV y video multicast en redes LAN. Trucos y recomendacionesNETGEAR Iberia
 
“見てわかる” ファイバーチャネルSAN基礎講座(第4弾)~続・間違わない!FC SAN導入のヒントとコツ~
“見てわかる” ファイバーチャネルSAN基礎講座(第4弾)~続・間違わない!FC SAN導入のヒントとコツ~“見てわかる” ファイバーチャネルSAN基礎講座(第4弾)~続・間違わない!FC SAN導入のヒントとコツ~
“見てわかる” ファイバーチャネルSAN基礎講座(第4弾)~続・間違わない!FC SAN導入のヒントとコツ~Brocade
 

Tendances (20)

“見てわかる” ファイバーチャネルSAN基礎講座(第3弾)~間違わない!FC SAN導入のヒントとコツ~
“見てわかる” ファイバーチャネルSAN基礎講座(第3弾)~間違わない!FC SAN導入のヒントとコツ~“見てわかる” ファイバーチャネルSAN基礎講座(第3弾)~間違わない!FC SAN導入のヒントとコツ~
“見てわかる” ファイバーチャネルSAN基礎講座(第3弾)~間違わない!FC SAN導入のヒントとコツ~
 
“見てわかる” ファイバーチャネルSAN基礎講座(第2弾)~FC SAN設計における勘所とは?~
“見てわかる” ファイバーチャネルSAN基礎講座(第2弾)~FC SAN設計における勘所とは?~“見てわかる” ファイバーチャネルSAN基礎講座(第2弾)~FC SAN設計における勘所とは?~
“見てわかる” ファイバーチャネルSAN基礎講座(第2弾)~FC SAN設計における勘所とは?~
 
ここまできた! ”第6世代”ファイバーチャネルがもたらす ストレージ・ネットワークの 新たな可能性とは?
ここまできた! ”第6世代”ファイバーチャネルがもたらす ストレージ・ネットワークの 新たな可能性とは?ここまできた! ”第6世代”ファイバーチャネルがもたらす ストレージ・ネットワークの 新たな可能性とは?
ここまできた! ”第6世代”ファイバーチャネルがもたらす ストレージ・ネットワークの 新たな可能性とは?
 
Aruba instant iap setup rev3
Aruba instant iap setup rev3Aruba instant iap setup rev3
Aruba instant iap setup rev3
 
4 1 1 ethernet base
4 1 1 ethernet base 4 1 1 ethernet base
4 1 1 ethernet base
 
Brocade SAN 製品概要
Brocade SAN 製品概要Brocade SAN 製品概要
Brocade SAN 製品概要
 
Tipos de Cablagens de Rede
Tipos de Cablagens de RedeTipos de Cablagens de Rede
Tipos de Cablagens de Rede
 
JunOS Jumstart 01 - JunOS Overview.ppt
JunOS Jumstart 01 - JunOS Overview.pptJunOS Jumstart 01 - JunOS Overview.ppt
JunOS Jumstart 01 - JunOS Overview.ppt
 
ブロケード FC ファブリックスイッチ オペレーション講座(後編)
ブロケード FC  ファブリックスイッチ オペレーション講座(後編)ブロケード FC  ファブリックスイッチ オペレーション講座(後編)
ブロケード FC ファブリックスイッチ オペレーション講座(後編)
 
Cisco ASA Firewalls
Cisco ASA FirewallsCisco ASA Firewalls
Cisco ASA Firewalls
 
Vlan lab
Vlan labVlan lab
Vlan lab
 
“見てわかる” ファイバーチャネルSAN基礎講座(第5弾)~さあ、いよいよ、運用です!~
“見てわかる” ファイバーチャネルSAN基礎講座(第5弾)~さあ、いよいよ、運用です!~“見てわかる” ファイバーチャネルSAN基礎講座(第5弾)~さあ、いよいよ、運用です!~
“見てわかる” ファイバーチャネルSAN基礎講座(第5弾)~さあ、いよいよ、運用です!~
 
CCNAv5 - S2: Chapter5 Inter Vlan Routing
CCNAv5 - S2: Chapter5 Inter Vlan RoutingCCNAv5 - S2: Chapter5 Inter Vlan Routing
CCNAv5 - S2: Chapter5 Inter Vlan Routing
 
OpenSPARC T1 Processor
OpenSPARC T1 ProcessorOpenSPARC T1 Processor
OpenSPARC T1 Processor
 
DOCSIS 3.0 SCTE Piedmont Chapter January 18th
DOCSIS 3.0 SCTE Piedmont Chapter January 18thDOCSIS 3.0 SCTE Piedmont Chapter January 18th
DOCSIS 3.0 SCTE Piedmont Chapter January 18th
 
Cisco-Press-CCNP-and-CCIE-Enterprise-Core-ENCOR-350-401-Official-Cert-Guide.pdf
Cisco-Press-CCNP-and-CCIE-Enterprise-Core-ENCOR-350-401-Official-Cert-Guide.pdfCisco-Press-CCNP-and-CCIE-Enterprise-Core-ENCOR-350-401-Official-Cert-Guide.pdf
Cisco-Press-CCNP-and-CCIE-Enterprise-Core-ENCOR-350-401-Official-Cert-Guide.pdf
 
Архитектура маршрутизатора ASR1k и его применение в сетях операторов связи.
Архитектура маршрутизатора ASR1k и его применение в сетях операторов связи. Архитектура маршрутизатора ASR1k и его применение в сетях операторов связи.
Архитектура маршрутизатора ASR1k и его применение в сетях операторов связи.
 
Introduction to Wi-Fi Direct
Introduction to Wi-Fi DirectIntroduction to Wi-Fi Direct
Introduction to Wi-Fi Direct
 
TV y video multicast en redes LAN. Trucos y recomendaciones
TV y video multicast en redes LAN. Trucos y recomendacionesTV y video multicast en redes LAN. Trucos y recomendaciones
TV y video multicast en redes LAN. Trucos y recomendaciones
 
“見てわかる” ファイバーチャネルSAN基礎講座(第4弾)~続・間違わない!FC SAN導入のヒントとコツ~
“見てわかる” ファイバーチャネルSAN基礎講座(第4弾)~続・間違わない!FC SAN導入のヒントとコツ~“見てわかる” ファイバーチャネルSAN基礎講座(第4弾)~続・間違わない!FC SAN導入のヒントとコツ~
“見てわかる” ファイバーチャネルSAN基礎講座(第4弾)~続・間違わない!FC SAN導入のヒントとコツ~
 

En vedette

Sun sparc enterprise t5120 and t5220 servers technical presentation
Sun sparc enterprise t5120 and t5220 servers technical presentationSun sparc enterprise t5120 and t5220 servers technical presentation
Sun sparc enterprise t5120 and t5220 servers technical presentationxKinAnx
 
Sun sparc enterprise t5440 server technical presentation
Sun sparc enterprise t5440 server technical presentationSun sparc enterprise t5440 server technical presentation
Sun sparc enterprise t5440 server technical presentationxKinAnx
 
Haiku os
Haiku osHaiku os
Haiku osnarca
 
Open Solaris 2008.05
Open Solaris 2008.05Open Solaris 2008.05
Open Solaris 2008.05Angad Singh
 
Game Based Learning for Language Learners
Game Based Learning for Language LearnersGame Based Learning for Language Learners
Game Based Learning for Language LearnersShelly Sanchez Terrell
 
Connecting With the Disconnected
Connecting With the DisconnectedConnecting With the Disconnected
Connecting With the DisconnectedChris Wejr
 

En vedette (6)

Sun sparc enterprise t5120 and t5220 servers technical presentation
Sun sparc enterprise t5120 and t5220 servers technical presentationSun sparc enterprise t5120 and t5220 servers technical presentation
Sun sparc enterprise t5120 and t5220 servers technical presentation
 
Sun sparc enterprise t5440 server technical presentation
Sun sparc enterprise t5440 server technical presentationSun sparc enterprise t5440 server technical presentation
Sun sparc enterprise t5440 server technical presentation
 
Haiku os
Haiku osHaiku os
Haiku os
 
Open Solaris 2008.05
Open Solaris 2008.05Open Solaris 2008.05
Open Solaris 2008.05
 
Game Based Learning for Language Learners
Game Based Learning for Language LearnersGame Based Learning for Language Learners
Game Based Learning for Language Learners
 
Connecting With the Disconnected
Connecting With the DisconnectedConnecting With the Disconnected
Connecting With the Disconnected
 

Similaire à Sun sparc enterprise t5140 and t5240 servers technical presentation

Maximizing Application Performance on Cray XT6 and XE6 Supercomputers DOD-MOD...
Maximizing Application Performance on Cray XT6 and XE6 Supercomputers DOD-MOD...Maximizing Application Performance on Cray XT6 and XE6 Supercomputers DOD-MOD...
Maximizing Application Performance on Cray XT6 and XE6 Supercomputers DOD-MOD...Jeff Larkin
 
Embedded Solutions 2010 : ARM-Cortex Based MCU's , by ARROW-ISRAEL
Embedded Solutions 2010 : ARM-Cortex Based MCU's , by ARROW-ISRAEL Embedded Solutions 2010 : ARM-Cortex Based MCU's , by ARROW-ISRAEL
Embedded Solutions 2010 : ARM-Cortex Based MCU's , by ARROW-ISRAEL New-Tech Magazine
 
Introducing the ADSP BF609 Blackfin Processors
Introducing the ADSP BF609 Blackfin ProcessorsIntroducing the ADSP BF609 Blackfin Processors
Introducing the ADSP BF609 Blackfin ProcessorsAnalog Devices, Inc.
 
Challenges in mixed signal
Challenges in mixed signal Challenges in mixed signal
Challenges in mixed signal chiportal
 
Sears Point Racetrack
Sears Point RacetrackSears Point Racetrack
Sears Point RacetrackDino, llc
 
Trend - HPC-29mai2012
Trend - HPC-29mai2012Trend - HPC-29mai2012
Trend - HPC-29mai2012Agora Group
 
Tablet in 2012
Tablet in 2012Tablet in 2012
Tablet in 2012JJ Wu
 
Mpc5121 econfs
Mpc5121 econfsMpc5121 econfs
Mpc5121 econfsDino, llc
 
Fujitsu Presents Post-K CPU Specifications
Fujitsu Presents Post-K CPU SpecificationsFujitsu Presents Post-K CPU Specifications
Fujitsu Presents Post-K CPU Specificationsinside-BigData.com
 
Lpc1769 68 67_66_65_64
Lpc1769 68 67_66_65_64Lpc1769 68 67_66_65_64
Lpc1769 68 67_66_65_64trowftd
 
Power Blades Implementation
Power Blades ImplementationPower Blades Implementation
Power Blades ImplementationAndrey Klyachkin
 
SUN主机产品介绍.ppt
SUN主机产品介绍.pptSUN主机产品介绍.ppt
SUN主机产品介绍.pptPencilData
 
ADVANCED DVB-C,DVB-S STB DEMOD
ADVANCED DVB-C,DVB-S STB DEMODADVANCED DVB-C,DVB-S STB DEMOD
ADVANCED DVB-C,DVB-S STB DEMODaniruddh Tyagi
 
ADVANCED DVB-C,DVB-S STB DEMOD
ADVANCED DVB-C,DVB-S STB DEMODADVANCED DVB-C,DVB-S STB DEMOD
ADVANCED DVB-C,DVB-S STB DEMODaniruddh Tyagi
 
ADVANCED DVB-C,DVB-S STB DEMOD
ADVANCED DVB-C,DVB-S STB DEMODADVANCED DVB-C,DVB-S STB DEMOD
ADVANCED DVB-C,DVB-S STB DEMODAniruddh Tyagi
 

Similaire à Sun sparc enterprise t5140 and t5240 servers technical presentation (20)

Maximizing Application Performance on Cray XT6 and XE6 Supercomputers DOD-MOD...
Maximizing Application Performance on Cray XT6 and XE6 Supercomputers DOD-MOD...Maximizing Application Performance on Cray XT6 and XE6 Supercomputers DOD-MOD...
Maximizing Application Performance on Cray XT6 and XE6 Supercomputers DOD-MOD...
 
Embedded Solutions 2010 : ARM-Cortex Based MCU's , by ARROW-ISRAEL
Embedded Solutions 2010 : ARM-Cortex Based MCU's , by ARROW-ISRAEL Embedded Solutions 2010 : ARM-Cortex Based MCU's , by ARROW-ISRAEL
Embedded Solutions 2010 : ARM-Cortex Based MCU's , by ARROW-ISRAEL
 
Introducing the ADSP BF609 Blackfin Processors
Introducing the ADSP BF609 Blackfin ProcessorsIntroducing the ADSP BF609 Blackfin Processors
Introducing the ADSP BF609 Blackfin Processors
 
Challenges in mixed signal
Challenges in mixed signal Challenges in mixed signal
Challenges in mixed signal
 
Ibm power7
Ibm power7Ibm power7
Ibm power7
 
Sears Point Racetrack
Sears Point RacetrackSears Point Racetrack
Sears Point Racetrack
 
Trend - HPC-29mai2012
Trend - HPC-29mai2012Trend - HPC-29mai2012
Trend - HPC-29mai2012
 
Tablet in 2012
Tablet in 2012Tablet in 2012
Tablet in 2012
 
Mpc5121 econfs
Mpc5121 econfsMpc5121 econfs
Mpc5121 econfs
 
Fpga technology
Fpga technologyFpga technology
Fpga technology
 
Fujitsu Presents Post-K CPU Specifications
Fujitsu Presents Post-K CPU SpecificationsFujitsu Presents Post-K CPU Specifications
Fujitsu Presents Post-K CPU Specifications
 
Gpu archi
Gpu archiGpu archi
Gpu archi
 
Nxp jul1311
Nxp jul1311Nxp jul1311
Nxp jul1311
 
Lpc1769 68 67_66_65_64
Lpc1769 68 67_66_65_64Lpc1769 68 67_66_65_64
Lpc1769 68 67_66_65_64
 
Power Blades Implementation
Power Blades ImplementationPower Blades Implementation
Power Blades Implementation
 
SUN主机产品介绍.ppt
SUN主机产品介绍.pptSUN主机产品介绍.ppt
SUN主机产品介绍.ppt
 
Lpc1768
Lpc1768Lpc1768
Lpc1768
 
ADVANCED DVB-C,DVB-S STB DEMOD
ADVANCED DVB-C,DVB-S STB DEMODADVANCED DVB-C,DVB-S STB DEMOD
ADVANCED DVB-C,DVB-S STB DEMOD
 
ADVANCED DVB-C,DVB-S STB DEMOD
ADVANCED DVB-C,DVB-S STB DEMODADVANCED DVB-C,DVB-S STB DEMOD
ADVANCED DVB-C,DVB-S STB DEMOD
 
ADVANCED DVB-C,DVB-S STB DEMOD
ADVANCED DVB-C,DVB-S STB DEMODADVANCED DVB-C,DVB-S STB DEMOD
ADVANCED DVB-C,DVB-S STB DEMOD
 

Plus de xKinAnx

Engage for success ibm spectrum accelerate 2
Engage for success   ibm spectrum accelerate 2Engage for success   ibm spectrum accelerate 2
Engage for success ibm spectrum accelerate 2xKinAnx
 
Accelerate with ibm storage ibm spectrum virtualize hyper swap deep dive
Accelerate with ibm storage  ibm spectrum virtualize hyper swap deep diveAccelerate with ibm storage  ibm spectrum virtualize hyper swap deep dive
Accelerate with ibm storage ibm spectrum virtualize hyper swap deep divexKinAnx
 
Software defined storage provisioning using ibm smart cloud
Software defined storage provisioning using ibm smart cloudSoftware defined storage provisioning using ibm smart cloud
Software defined storage provisioning using ibm smart cloudxKinAnx
 
Ibm spectrum virtualize 101
Ibm spectrum virtualize 101 Ibm spectrum virtualize 101
Ibm spectrum virtualize 101 xKinAnx
 
Accelerate with ibm storage ibm spectrum virtualize hyper swap deep dive dee...
Accelerate with ibm storage  ibm spectrum virtualize hyper swap deep dive dee...Accelerate with ibm storage  ibm spectrum virtualize hyper swap deep dive dee...
Accelerate with ibm storage ibm spectrum virtualize hyper swap deep dive dee...xKinAnx
 
04 empalis -ibm_spectrum_protect_-_strategy_and_directions
04 empalis -ibm_spectrum_protect_-_strategy_and_directions04 empalis -ibm_spectrum_protect_-_strategy_and_directions
04 empalis -ibm_spectrum_protect_-_strategy_and_directionsxKinAnx
 
Ibm spectrum scale fundamentals workshop for americas part 1 components archi...
Ibm spectrum scale fundamentals workshop for americas part 1 components archi...Ibm spectrum scale fundamentals workshop for americas part 1 components archi...
Ibm spectrum scale fundamentals workshop for americas part 1 components archi...xKinAnx
 
Ibm spectrum scale fundamentals workshop for americas part 2 IBM Spectrum Sca...
Ibm spectrum scale fundamentals workshop for americas part 2 IBM Spectrum Sca...Ibm spectrum scale fundamentals workshop for americas part 2 IBM Spectrum Sca...
Ibm spectrum scale fundamentals workshop for americas part 2 IBM Spectrum Sca...xKinAnx
 
Ibm spectrum scale fundamentals workshop for americas part 3 Information Life...
Ibm spectrum scale fundamentals workshop for americas part 3 Information Life...Ibm spectrum scale fundamentals workshop for americas part 3 Information Life...
Ibm spectrum scale fundamentals workshop for americas part 3 Information Life...xKinAnx
 
Ibm spectrum scale fundamentals workshop for americas part 4 Replication, Str...
Ibm spectrum scale fundamentals workshop for americas part 4 Replication, Str...Ibm spectrum scale fundamentals workshop for americas part 4 Replication, Str...
Ibm spectrum scale fundamentals workshop for americas part 4 Replication, Str...xKinAnx
 
Ibm spectrum scale fundamentals workshop for americas part 4 spectrum scale_r...
Ibm spectrum scale fundamentals workshop for americas part 4 spectrum scale_r...Ibm spectrum scale fundamentals workshop for americas part 4 spectrum scale_r...
Ibm spectrum scale fundamentals workshop for americas part 4 spectrum scale_r...xKinAnx
 
Ibm spectrum scale fundamentals workshop for americas part 5 spectrum scale_c...
Ibm spectrum scale fundamentals workshop for americas part 5 spectrum scale_c...Ibm spectrum scale fundamentals workshop for americas part 5 spectrum scale_c...
Ibm spectrum scale fundamentals workshop for americas part 5 spectrum scale_c...xKinAnx
 
Ibm spectrum scale fundamentals workshop for americas part 6 spectrumscale el...
Ibm spectrum scale fundamentals workshop for americas part 6 spectrumscale el...Ibm spectrum scale fundamentals workshop for americas part 6 spectrumscale el...
Ibm spectrum scale fundamentals workshop for americas part 6 spectrumscale el...xKinAnx
 
Ibm spectrum scale fundamentals workshop for americas part 7 spectrumscale el...
Ibm spectrum scale fundamentals workshop for americas part 7 spectrumscale el...Ibm spectrum scale fundamentals workshop for americas part 7 spectrumscale el...
Ibm spectrum scale fundamentals workshop for americas part 7 spectrumscale el...xKinAnx
 
Ibm spectrum scale fundamentals workshop for americas part 8 spectrumscale ba...
Ibm spectrum scale fundamentals workshop for americas part 8 spectrumscale ba...Ibm spectrum scale fundamentals workshop for americas part 8 spectrumscale ba...
Ibm spectrum scale fundamentals workshop for americas part 8 spectrumscale ba...xKinAnx
 
Ibm spectrum scale fundamentals workshop for americas part 5 ess gnr-usecases...
Ibm spectrum scale fundamentals workshop for americas part 5 ess gnr-usecases...Ibm spectrum scale fundamentals workshop for americas part 5 ess gnr-usecases...
Ibm spectrum scale fundamentals workshop for americas part 5 ess gnr-usecases...xKinAnx
 
Presentation disaster recovery in virtualization and cloud
Presentation   disaster recovery in virtualization and cloudPresentation   disaster recovery in virtualization and cloud
Presentation disaster recovery in virtualization and cloudxKinAnx
 
Presentation disaster recovery for oracle fusion middleware with the zfs st...
Presentation   disaster recovery for oracle fusion middleware with the zfs st...Presentation   disaster recovery for oracle fusion middleware with the zfs st...
Presentation disaster recovery for oracle fusion middleware with the zfs st...xKinAnx
 
Presentation differentiated virtualization for enterprise clouds, large and...
Presentation   differentiated virtualization for enterprise clouds, large and...Presentation   differentiated virtualization for enterprise clouds, large and...
Presentation differentiated virtualization for enterprise clouds, large and...xKinAnx
 
Presentation desktops for the cloud the view rollout
Presentation   desktops for the cloud the view rolloutPresentation   desktops for the cloud the view rollout
Presentation desktops for the cloud the view rolloutxKinAnx
 

Plus de xKinAnx (20)

Engage for success ibm spectrum accelerate 2
Engage for success   ibm spectrum accelerate 2Engage for success   ibm spectrum accelerate 2
Engage for success ibm spectrum accelerate 2
 
Accelerate with ibm storage ibm spectrum virtualize hyper swap deep dive
Accelerate with ibm storage  ibm spectrum virtualize hyper swap deep diveAccelerate with ibm storage  ibm spectrum virtualize hyper swap deep dive
Accelerate with ibm storage ibm spectrum virtualize hyper swap deep dive
 
Software defined storage provisioning using ibm smart cloud
Software defined storage provisioning using ibm smart cloudSoftware defined storage provisioning using ibm smart cloud
Software defined storage provisioning using ibm smart cloud
 
Ibm spectrum virtualize 101
Ibm spectrum virtualize 101 Ibm spectrum virtualize 101
Ibm spectrum virtualize 101
 
Accelerate with ibm storage ibm spectrum virtualize hyper swap deep dive dee...
Accelerate with ibm storage  ibm spectrum virtualize hyper swap deep dive dee...Accelerate with ibm storage  ibm spectrum virtualize hyper swap deep dive dee...
Accelerate with ibm storage ibm spectrum virtualize hyper swap deep dive dee...
 
04 empalis -ibm_spectrum_protect_-_strategy_and_directions
04 empalis -ibm_spectrum_protect_-_strategy_and_directions04 empalis -ibm_spectrum_protect_-_strategy_and_directions
04 empalis -ibm_spectrum_protect_-_strategy_and_directions
 
Ibm spectrum scale fundamentals workshop for americas part 1 components archi...
Ibm spectrum scale fundamentals workshop for americas part 1 components archi...Ibm spectrum scale fundamentals workshop for americas part 1 components archi...
Ibm spectrum scale fundamentals workshop for americas part 1 components archi...
 
Ibm spectrum scale fundamentals workshop for americas part 2 IBM Spectrum Sca...
Ibm spectrum scale fundamentals workshop for americas part 2 IBM Spectrum Sca...Ibm spectrum scale fundamentals workshop for americas part 2 IBM Spectrum Sca...
Ibm spectrum scale fundamentals workshop for americas part 2 IBM Spectrum Sca...
 
Ibm spectrum scale fundamentals workshop for americas part 3 Information Life...
Ibm spectrum scale fundamentals workshop for americas part 3 Information Life...Ibm spectrum scale fundamentals workshop for americas part 3 Information Life...
Ibm spectrum scale fundamentals workshop for americas part 3 Information Life...
 
Ibm spectrum scale fundamentals workshop for americas part 4 Replication, Str...
Ibm spectrum scale fundamentals workshop for americas part 4 Replication, Str...Ibm spectrum scale fundamentals workshop for americas part 4 Replication, Str...
Ibm spectrum scale fundamentals workshop for americas part 4 Replication, Str...
 
Ibm spectrum scale fundamentals workshop for americas part 4 spectrum scale_r...
Ibm spectrum scale fundamentals workshop for americas part 4 spectrum scale_r...Ibm spectrum scale fundamentals workshop for americas part 4 spectrum scale_r...
Ibm spectrum scale fundamentals workshop for americas part 4 spectrum scale_r...
 
Ibm spectrum scale fundamentals workshop for americas part 5 spectrum scale_c...
Ibm spectrum scale fundamentals workshop for americas part 5 spectrum scale_c...Ibm spectrum scale fundamentals workshop for americas part 5 spectrum scale_c...
Ibm spectrum scale fundamentals workshop for americas part 5 spectrum scale_c...
 
Ibm spectrum scale fundamentals workshop for americas part 6 spectrumscale el...
Ibm spectrum scale fundamentals workshop for americas part 6 spectrumscale el...Ibm spectrum scale fundamentals workshop for americas part 6 spectrumscale el...
Ibm spectrum scale fundamentals workshop for americas part 6 spectrumscale el...
 
Ibm spectrum scale fundamentals workshop for americas part 7 spectrumscale el...
Ibm spectrum scale fundamentals workshop for americas part 7 spectrumscale el...Ibm spectrum scale fundamentals workshop for americas part 7 spectrumscale el...
Ibm spectrum scale fundamentals workshop for americas part 7 spectrumscale el...
 
Ibm spectrum scale fundamentals workshop for americas part 8 spectrumscale ba...
Ibm spectrum scale fundamentals workshop for americas part 8 spectrumscale ba...Ibm spectrum scale fundamentals workshop for americas part 8 spectrumscale ba...
Ibm spectrum scale fundamentals workshop for americas part 8 spectrumscale ba...
 
Ibm spectrum scale fundamentals workshop for americas part 5 ess gnr-usecases...
Ibm spectrum scale fundamentals workshop for americas part 5 ess gnr-usecases...Ibm spectrum scale fundamentals workshop for americas part 5 ess gnr-usecases...
Ibm spectrum scale fundamentals workshop for americas part 5 ess gnr-usecases...
 
Presentation disaster recovery in virtualization and cloud
Presentation   disaster recovery in virtualization and cloudPresentation   disaster recovery in virtualization and cloud
Presentation disaster recovery in virtualization and cloud
 
Presentation disaster recovery for oracle fusion middleware with the zfs st...
Presentation   disaster recovery for oracle fusion middleware with the zfs st...Presentation   disaster recovery for oracle fusion middleware with the zfs st...
Presentation disaster recovery for oracle fusion middleware with the zfs st...
 
Presentation differentiated virtualization for enterprise clouds, large and...
Presentation   differentiated virtualization for enterprise clouds, large and...Presentation   differentiated virtualization for enterprise clouds, large and...
Presentation differentiated virtualization for enterprise clouds, large and...
 
Presentation desktops for the cloud the view rollout
Presentation   desktops for the cloud the view rolloutPresentation   desktops for the cloud the view rollout
Presentation desktops for the cloud the view rollout
 

Dernier

The Codex of Business Writing Software for Real-World Solutions 2.pptx
The Codex of Business Writing Software for Real-World Solutions 2.pptxThe Codex of Business Writing Software for Real-World Solutions 2.pptx
The Codex of Business Writing Software for Real-World Solutions 2.pptxMalak Abu Hammad
 
Finology Group – Insurtech Innovation Award 2024
Finology Group – Insurtech Innovation Award 2024Finology Group – Insurtech Innovation Award 2024
Finology Group – Insurtech Innovation Award 2024The Digital Insurer
 
IAC 2024 - IA Fast Track to Search Focused AI Solutions
IAC 2024 - IA Fast Track to Search Focused AI SolutionsIAC 2024 - IA Fast Track to Search Focused AI Solutions
IAC 2024 - IA Fast Track to Search Focused AI SolutionsEnterprise Knowledge
 
Driving Behavioral Change for Information Management through Data-Driven Gree...
Driving Behavioral Change for Information Management through Data-Driven Gree...Driving Behavioral Change for Information Management through Data-Driven Gree...
Driving Behavioral Change for Information Management through Data-Driven Gree...Enterprise Knowledge
 
Tata AIG General Insurance Company - Insurer Innovation Award 2024
Tata AIG General Insurance Company - Insurer Innovation Award 2024Tata AIG General Insurance Company - Insurer Innovation Award 2024
Tata AIG General Insurance Company - Insurer Innovation Award 2024The Digital Insurer
 
2024: Domino Containers - The Next Step. News from the Domino Container commu...
2024: Domino Containers - The Next Step. News from the Domino Container commu...2024: Domino Containers - The Next Step. News from the Domino Container commu...
2024: Domino Containers - The Next Step. News from the Domino Container commu...Martijn de Jong
 
How to convert PDF to text with Nanonets
How to convert PDF to text with NanonetsHow to convert PDF to text with Nanonets
How to convert PDF to text with Nanonetsnaman860154
 
Data Cloud, More than a CDP by Matt Robison
Data Cloud, More than a CDP by Matt RobisonData Cloud, More than a CDP by Matt Robison
Data Cloud, More than a CDP by Matt RobisonAnna Loughnan Colquhoun
 
EIS-Webinar-Prompt-Knowledge-Eng-2024-04-08.pptx
EIS-Webinar-Prompt-Knowledge-Eng-2024-04-08.pptxEIS-Webinar-Prompt-Knowledge-Eng-2024-04-08.pptx
EIS-Webinar-Prompt-Knowledge-Eng-2024-04-08.pptxEarley Information Science
 
Apidays Singapore 2024 - Building Digital Trust in a Digital Economy by Veron...
Apidays Singapore 2024 - Building Digital Trust in a Digital Economy by Veron...Apidays Singapore 2024 - Building Digital Trust in a Digital Economy by Veron...
Apidays Singapore 2024 - Building Digital Trust in a Digital Economy by Veron...apidays
 
A Call to Action for Generative AI in 2024
A Call to Action for Generative AI in 2024A Call to Action for Generative AI in 2024
A Call to Action for Generative AI in 2024Results
 
Handwritten Text Recognition for manuscripts and early printed texts
Handwritten Text Recognition for manuscripts and early printed textsHandwritten Text Recognition for manuscripts and early printed texts
Handwritten Text Recognition for manuscripts and early printed textsMaria Levchenko
 
Unblocking The Main Thread Solving ANRs and Frozen Frames
Unblocking The Main Thread Solving ANRs and Frozen FramesUnblocking The Main Thread Solving ANRs and Frozen Frames
Unblocking The Main Thread Solving ANRs and Frozen FramesSinan KOZAK
 
08448380779 Call Girls In Friends Colony Women Seeking Men
08448380779 Call Girls In Friends Colony Women Seeking Men08448380779 Call Girls In Friends Colony Women Seeking Men
08448380779 Call Girls In Friends Colony Women Seeking MenDelhi Call girls
 
08448380779 Call Girls In Diplomatic Enclave Women Seeking Men
08448380779 Call Girls In Diplomatic Enclave Women Seeking Men08448380779 Call Girls In Diplomatic Enclave Women Seeking Men
08448380779 Call Girls In Diplomatic Enclave Women Seeking MenDelhi Call girls
 
Axa Assurance Maroc - Insurer Innovation Award 2024
Axa Assurance Maroc - Insurer Innovation Award 2024Axa Assurance Maroc - Insurer Innovation Award 2024
Axa Assurance Maroc - Insurer Innovation Award 2024The Digital Insurer
 
Strategies for Unlocking Knowledge Management in Microsoft 365 in the Copilot...
Strategies for Unlocking Knowledge Management in Microsoft 365 in the Copilot...Strategies for Unlocking Knowledge Management in Microsoft 365 in the Copilot...
Strategies for Unlocking Knowledge Management in Microsoft 365 in the Copilot...Drew Madelung
 
Kalyanpur ) Call Girls in Lucknow Finest Escorts Service 🍸 8923113531 🎰 Avail...
Kalyanpur ) Call Girls in Lucknow Finest Escorts Service 🍸 8923113531 🎰 Avail...Kalyanpur ) Call Girls in Lucknow Finest Escorts Service 🍸 8923113531 🎰 Avail...
Kalyanpur ) Call Girls in Lucknow Finest Escorts Service 🍸 8923113531 🎰 Avail...gurkirankumar98700
 
Histor y of HAM Radio presentation slide
Histor y of HAM Radio presentation slideHistor y of HAM Radio presentation slide
Histor y of HAM Radio presentation slidevu2urc
 
Presentation on how to chat with PDF using ChatGPT code interpreter
Presentation on how to chat with PDF using ChatGPT code interpreterPresentation on how to chat with PDF using ChatGPT code interpreter
Presentation on how to chat with PDF using ChatGPT code interpreternaman860154
 

Dernier (20)

The Codex of Business Writing Software for Real-World Solutions 2.pptx
The Codex of Business Writing Software for Real-World Solutions 2.pptxThe Codex of Business Writing Software for Real-World Solutions 2.pptx
The Codex of Business Writing Software for Real-World Solutions 2.pptx
 
Finology Group – Insurtech Innovation Award 2024
Finology Group – Insurtech Innovation Award 2024Finology Group – Insurtech Innovation Award 2024
Finology Group – Insurtech Innovation Award 2024
 
IAC 2024 - IA Fast Track to Search Focused AI Solutions
IAC 2024 - IA Fast Track to Search Focused AI SolutionsIAC 2024 - IA Fast Track to Search Focused AI Solutions
IAC 2024 - IA Fast Track to Search Focused AI Solutions
 
Driving Behavioral Change for Information Management through Data-Driven Gree...
Driving Behavioral Change for Information Management through Data-Driven Gree...Driving Behavioral Change for Information Management through Data-Driven Gree...
Driving Behavioral Change for Information Management through Data-Driven Gree...
 
Tata AIG General Insurance Company - Insurer Innovation Award 2024
Tata AIG General Insurance Company - Insurer Innovation Award 2024Tata AIG General Insurance Company - Insurer Innovation Award 2024
Tata AIG General Insurance Company - Insurer Innovation Award 2024
 
2024: Domino Containers - The Next Step. News from the Domino Container commu...
2024: Domino Containers - The Next Step. News from the Domino Container commu...2024: Domino Containers - The Next Step. News from the Domino Container commu...
2024: Domino Containers - The Next Step. News from the Domino Container commu...
 
How to convert PDF to text with Nanonets
How to convert PDF to text with NanonetsHow to convert PDF to text with Nanonets
How to convert PDF to text with Nanonets
 
Data Cloud, More than a CDP by Matt Robison
Data Cloud, More than a CDP by Matt RobisonData Cloud, More than a CDP by Matt Robison
Data Cloud, More than a CDP by Matt Robison
 
EIS-Webinar-Prompt-Knowledge-Eng-2024-04-08.pptx
EIS-Webinar-Prompt-Knowledge-Eng-2024-04-08.pptxEIS-Webinar-Prompt-Knowledge-Eng-2024-04-08.pptx
EIS-Webinar-Prompt-Knowledge-Eng-2024-04-08.pptx
 
Apidays Singapore 2024 - Building Digital Trust in a Digital Economy by Veron...
Apidays Singapore 2024 - Building Digital Trust in a Digital Economy by Veron...Apidays Singapore 2024 - Building Digital Trust in a Digital Economy by Veron...
Apidays Singapore 2024 - Building Digital Trust in a Digital Economy by Veron...
 
A Call to Action for Generative AI in 2024
A Call to Action for Generative AI in 2024A Call to Action for Generative AI in 2024
A Call to Action for Generative AI in 2024
 
Handwritten Text Recognition for manuscripts and early printed texts
Handwritten Text Recognition for manuscripts and early printed textsHandwritten Text Recognition for manuscripts and early printed texts
Handwritten Text Recognition for manuscripts and early printed texts
 
Unblocking The Main Thread Solving ANRs and Frozen Frames
Unblocking The Main Thread Solving ANRs and Frozen FramesUnblocking The Main Thread Solving ANRs and Frozen Frames
Unblocking The Main Thread Solving ANRs and Frozen Frames
 
08448380779 Call Girls In Friends Colony Women Seeking Men
08448380779 Call Girls In Friends Colony Women Seeking Men08448380779 Call Girls In Friends Colony Women Seeking Men
08448380779 Call Girls In Friends Colony Women Seeking Men
 
08448380779 Call Girls In Diplomatic Enclave Women Seeking Men
08448380779 Call Girls In Diplomatic Enclave Women Seeking Men08448380779 Call Girls In Diplomatic Enclave Women Seeking Men
08448380779 Call Girls In Diplomatic Enclave Women Seeking Men
 
Axa Assurance Maroc - Insurer Innovation Award 2024
Axa Assurance Maroc - Insurer Innovation Award 2024Axa Assurance Maroc - Insurer Innovation Award 2024
Axa Assurance Maroc - Insurer Innovation Award 2024
 
Strategies for Unlocking Knowledge Management in Microsoft 365 in the Copilot...
Strategies for Unlocking Knowledge Management in Microsoft 365 in the Copilot...Strategies for Unlocking Knowledge Management in Microsoft 365 in the Copilot...
Strategies for Unlocking Knowledge Management in Microsoft 365 in the Copilot...
 
Kalyanpur ) Call Girls in Lucknow Finest Escorts Service 🍸 8923113531 🎰 Avail...
Kalyanpur ) Call Girls in Lucknow Finest Escorts Service 🍸 8923113531 🎰 Avail...Kalyanpur ) Call Girls in Lucknow Finest Escorts Service 🍸 8923113531 🎰 Avail...
Kalyanpur ) Call Girls in Lucknow Finest Escorts Service 🍸 8923113531 🎰 Avail...
 
Histor y of HAM Radio presentation slide
Histor y of HAM Radio presentation slideHistor y of HAM Radio presentation slide
Histor y of HAM Radio presentation slide
 
Presentation on how to chat with PDF using ChatGPT code interpreter
Presentation on how to chat with PDF using ChatGPT code interpreterPresentation on how to chat with PDF using ChatGPT code interpreter
Presentation on how to chat with PDF using ChatGPT code interpreter
 

Sun sparc enterprise t5140 and t5240 servers technical presentation

  • 1. Sun SPARC Enterprise T5140 and T5240 Rack Servers Technical Training Course <Name> <Job Title> Sun Microsystems, Inc. 1
  • 2. UltraSPARC T2: • Up to 8 cores @1.2GHz or 1.4GHz TrueSystem On a Chip • Up to 64 threads per CPU • Up to 16 FB-DIMMs, 4 memory controllers FB DIMM FB DIMM FB DIMM FB DIMM > Up to 64GB memory (4GB DIMMs) > 2.5x memory BW of UltraSPARC T1 FB DIMM FB DIMM FB DIMM FB DIMM • 8 x fully pipelined Floating Point units / core, 1 per core MCU MCU MCU MCU • Dual 10Gbit Ethernet and PCI-E integrated onto chip L2$ L2$ L2$ L2$ L2$ L2$ L2$ L2$ • 4MB L2 (8 banks) 16 way associative Full Cross Bar • Enhanced MAU/Security co-processor C0 C1 C2 C3 C4 C5 C6 C7 per core FPU FPU FPU FPU FPU FPU FPU FPU MAU MAU MAU MAU MAU MAU MAU MAU > DES, 3DES, AES, RC4, SHA1, DMA Sub-System SHA256, MD5, RSA to 2048 key, ECC,CRC32 NIU Sys I/F • Advanced Power saving features (E-net+) Buffer Switch Core PCI-E • 65nm process technology Power ~95W <1.5W/thread x8 @2.5GHz 2x 10GE Ethernet 4GBytes/s bi-directional Sun Internal and Approved Partners Only 2
  • 3. UltraSPARC T2 Processor SPC SPARCv9 CMT Core L2 Data L2 Data Bank 0 Bank 4 CCX Core-Cache Crossbar L2B0 SPARC SPARC SPARC SPARC L2B4 L2$ Level 2 Cache Bank L2 Data Core 0 Core 1 Core 5 Core 4 L2 Data CLC Coherence & Link Controller Bank 1 Bank 5 MCU Memory Control Unit L2B1 L2B5 SIU System Interface Unit L2 L2 L2 L2 MCU0 MCU2 NCU Non-cacheable Unit NCU TAG0 TAG1 TAG5 TAG4 FSR MAC Media Access Controller EFU MCU1 MCU3 DMU Data Management Unit SIO SII L2B3 CCX L2B7 FSR CCU PEU PCI Express Unit L2 Data L2 Data Bank 3 Bank 7 L2 L2 L2 L2 L2B2 L2B6 TAG2 TAG3 TAG7 TAG6 L2 Data L2 Data Bank 2 Bank 6 SPARC SPARC SPARC SPARC DMU Core 2 Core 3 Core 7 Core 6 RDP TDS PEU RTX PSR ESR FSR MAC For a video tour with Rick Hetherington, go to http://www.youtube.com/watch?v=B8DNexYcsa4 Sun Internal and Approved Partners Only 3
  • 4. UltraSPARC T2 Plus: • Per Socket Multi-Socket US T2 > Up to 8 cores @1.2GHz or Each Coherency Link 6.4GBytes/s per direction, 12.8GB/s total 1.4GHz 4 x Coherency links give Snoop bandwidth of 51.2GB/s > Up to 64 Threads per socket 4x Coherency > 4MB L2$ 8 banks x 16 Way SA Links > Up to 8 FPU's, 1 per core FB-DIMM FB-DIMM FB-DIMM FB-DIMM > Up to 8 Crypto cores, 1 per core FB-DIMM FB-DIMM FB-DIMM FB-DIMM > DES, 3DES, AES, RC4, SHA1, SHA256, MD5, RSA to 2048 key, ECC,CRC32 MCU MCU > 2 memory Controllers, 16 DIMMS CU CU CU CU > 25Read+13WriteGB/s Memory BW L2$ L2$ L2$ L2$ L2$ L2$ L2$ L2$ > One x8 PCIe interface Full Cross Bar • Per system CO C1 C2 C3 C4 C5 C6 C7 > 2 sockets glue-less FPU FPU FPU FPU FPU FPU FPU FPU > 4 sockets using UST2 Plus XBR MAU MAU MAU MAU MAU MAU MAU MAU > 16 or 32 PCIe lanes on 2 or 4 System I/F PCI-Express Socket systems • 65nm process technology SSI x8 @2.5GHz Bus Power ~105W 4GBytes/s <1.5W/thread bi-directional Sun Internal and Approved Partners Only 4
  • 5. UltraSPARC T2 Plus Processor SPC SPARCv9 CMT Core CCX Core-Cache Crossbar L2$ Level 2 Cache Bank CLC Coherence & Link Controller MCU Memory Control Unit SIU System Interface Unit NCU Non-cacheable Unit NCX Non-cacheable Crossbar DMU Data Management Unit PEU PCI Express Unit Sun Internal and Approved Partners Only 5
  • 6. CMT Processor Comparison UltraSPARC T1 UltraSPARC T2 UltraSPARC T2 Plus Technology 90nm 65nm 65nm # of Cores 8 8 8 # of Threads 32 64 64 # of Sockets 1 1 1–4 Core Frequency (Ghz) 1 – 1.4 1.2 – 1.4 1.2 – 1.4 Execution pipelines per core 1 2 2 Instructions per cycle per pipe 1 1 1 FPUs per chip 1 8 8 I$ size (per core) 16KB 16KB 16KB D$ size (per core) 8KB 8KB 8KB L2$ size/Set Association 3MB/12-Way 4MB/16-Way 4MB/16-Way Memory Type DDR2 FBDIMM-1 FBDIMM-1 Memory Bandwidth (GB/s) 21.3 42READ + 21WRITE 25READ + 13WRITE Coherence Bandwdth (GB/s) - - 4 x (6.4READ +6.4WRITE) IO Bus JBUS x8 PCIe x8 PCIe IO Bandwidth (GB/s) 2.5 2+2 2+2 On-chip Networking - 2 x 10GE - Crypto Acceleration RSA RSA, RC4, DES, 3DES, AES, SHA1-256, MD5 Power (Watts, Watts/thread) 72, 2.25 95, 1.5 105, 1.6 * Sun Internal and Approved Partners Only 6
  • 7. UltraSPARC T2 Plus 2-Socket System Coherency Links Dual Channel Dual Channel Dual Channel Dual Channel FBDIMM FBDIMM FBDIMM FBDIMM Memory Controller Memory Controller Memory Controller Memory Controller Coherence Coherence Coherence Coherence Coherence Coherence Coherence Coherence Unit Unit Unit Unit Unit Unit Unit Unit UltraSPARC T2 Plus Cores, Crossbar, L2$ UltraSPARC T2 Plus Cores, Crossbar, L2$ (8 cores, 64 threads, 4MB L2$) (8 cores, 64 threads, 4MB L2$) PCI-Express NCU, DMU NCX PCI-Express NCU, DMU NCX System IO (Network, Disk, etc.) Sun Internal and Approved Partners Only 7
  • 8. UltraSPARC T2/Plus CPU Core Block Diagram • IFU – Instruction Fetch Unit > 16 KB I$, 32B lines, 8-way SA TLU IFU > 64-entry fully-associative ITLB • EXU0/1 – Integer Execution Units > 4 threads share each unit > Executes one integer instruction/cycle EXU0 EXU1 • LSU – Load/Store Unit > 8KB D$, 16B lines, 4-way SA MMU/ > 128-entry fully-associative DTLB HWTW • FGU – Floating/Graphics Unit • SPU – Stream Processing Unit > Cryptographic acceleration SPU FGU LSU • TLU – Trap Logic Unit > Updates machine state, handles exceptions and interrupts • MMU – Memory Management Unit > Hardware tablewalk (HWTW) Gasket – TLB miss handled by hardware > 8KB, 64KB, 4MB, 256MB pages xbar/L2 Sun Internal and Approved Partners Only 8
  • 9. Floating Point Unit • Each Core has its own Floating Point Unit. This removes completely the 2% FP restriction of T1. • Only a 6 cycle penalty to the FPU > T1 required upwards of 28 cycles • Fully-pipelined (except divide/sqrt) Data > Divide/sqrt in parallel with add or multiply operations of other threads • Full VIS 2.0 implementation in hardware, no emulation • FPU performs integer multiply, divide, population count • Multiplier incorporates enhancements for offloading modular arithmetic operations to the Crypto Unit ● ● Sun Internal and Approved Partners Only 9
  • 10. FB-DIMM Memory Interface Feature UltraSPARC T1 UltraSPARC T2 UltraSPARC T2 Plus Require Pins 1000 440 208 Available Bandwidth 23GBytes/second 50Gbytes/second 37.5Gbytes/second/socket Up to 64x DIMM slots Up to 32x DIMM slots/socket Memory Capacity up to 16x DIMM slots T5x20 uses 16 DIMM slots T5x40 uses 8/16 DIMM slots Data Memory Controllers 4 4 2 Memory Latency 96ns 126ns 126ns DIMM speeds 400MHz 667MHz 667MHz DIMM Power 7watts/DIMM 12.5Watts/DIMM 12.5Watts/DIMM ● ● Sun Internal and Approved Partners Only 10
  • 11. 10/100/1000/10GbE Network Interfaces • Uses the Neptune Chip on the Motherboard which provides > Two RJ-45 ports dedicated for 10/100/1000 > Two RJ-45 ports capable of 10/100/1000 – Fitting a XAUI adapter disables the one of these ports per XAUI • Same 10 GbE XAUI cards as T5x20 server • 16 Rx and 24 Tx DMA channels for virtualization – Integrated NIU in T2 has 16 Tx channels Data – Raw UDP Tx performance on Neptune > T2 NIU – T2 processor network typically outperforms Neptune on most network benchmarks • Packet classification > Rx data can be HW classified at layer 2 ,3 and 4 – Put into the separate Rx DMA buffers by classification rules • Same 'nxge' device driver as T2 NIU. • Performance estimates, testing/tuning ongoing – 1 port 10GbE TX/RX = 9.3 Gbps with CPUs still 65-75% idle ● – 2 port 10GbE TX/RX = 12-19Gbps (better if dedicate RX/TX ports) ● Sun Internal and Approved Partners Only 11
  • 12. T5140/T5240 Extreme Rackmount Density Dual UltraSPARC T2 Plus • 1 / 2RU chassis, 28” depth • Two sockets > Up to 8 cores @ 1.2GHz at RR – 1.4GHz to follow > Up to 128 threads • 161U/2U/ 322U FB-DIMM memory slots > 64/128GB of memory, 4GB DIMMs High Reliability • Up to 128 threads / 128GB memory / 128 • Up to 4 (1U) or 8/16 (2U) Hot-Plug LDoms in a 1U / 2U redundant chassis SATA/SAS 2.5” HDD (Raid 0,1) > RAID 5 BBWC card post-RR • Over 5,100 threads per rack ! • Redundant, hot-swappable PSUs and • High RAS and I/O bandwidth Fans. DC Option for 2U • Certain Configs are 'Hi-Line Power' only • Scale-Up / Scale-Out of application infrastructure Expandable • 3/6 PCI-E expansion slots > including 2 x 10 GBE I/0 XAUI slots • 4 x 1GbE Ethernet as standard • 4 USB ports Sun Internal and Approved Partners Only 12
  • 13. T5x40 Standard Configurations (PTO) Part Number Description 1RU 2 x 4 Core, 64 Threads, 1.2Ghz, 8GB (8 X 1GB), SETPAAE1Z 4 disk capable, 2x 146GB disks, 2x 720W PSU, DVD 2 x 6 Core, 96 Threads, 1.2Ghz, 16GB (8 X 2GB), SETPBGE1Z 4 disk capable, 2x 146GB disks, 2x 720W PSU, DVD 2 x 8 Core, 128 Threads, 1.2Ghz, 32GB (16 X 2GB), SETPCJE1Z 4 disk capable, 2x 146GB disks, 2x 720W PSU, DVD 2 x 8 Core, 128 Threads, 1.2Ghz, 64GB (16 X 4GB), SETPCPE1Z 4 disk capable, 2x 146GB disks, 2x 720W PSU, DVD Part Number Description 2RU 2 x 6 Core, 96 Threads, 1.2Ghz, 8GB (8 X 1GB), SEUPBAE1Z 8 disk capable, 2x 146GB disks, 2x 1100W PSU, DVD 2 x 8 Core, 128 Threads, 1.2Ghz, 32GB (16 X 2GB), SEUPCJE1Z 8 disk capable, 2x 146GB disks, 2x 1100W PSU, DVD 2 x 8 Core, 128 Threads, 1.2Ghz, 64GB (16 X 4GB), SEUPCPE1Z 8 disk capable, 2x 146GB disks, 2x 1100W PSU, DVD 2 x 8 Core, 128 Threads, 1.2Ghz, 64GB (16 X 4GB), SEUPCPE2Z 16 disk capable, 2x 146GB disks, 2x 1100W PSU, DVD HIGHLINE POWER ONLY (220VAC) 2 x 8 Core, 128 Threads, 1.4Ghz, 64GB (16 X 4GB), SEUPDPE1Z 16 disk capable, 2x 146GB disks, 2x 1100W PSU, DVD HIGHLINE POWER ONLY (220VAC) Sun Internal and Approved Partners Only 13
  • 14. Sun Fire T1000/T5120/T5140 Differences Feature Sun Fire T1000 SPARC Enterprise T5120 SPARC Enterprise T5140 Form Factor 1U, 18¾” deep 1U, 28” deep 1U, 28” deep UltraSPARC T1 UltraSPARC T2 2x UltraSPARC T2 Plus CPU 1.0 GHz, 16-32 threads 1.2/1.4 GHz 32-64 threads 1.2/1.4 GHz 64-128 threads DDR2 32GB Max FB-DIMM 64GB MAX FB-DIMM 64GB MAX Memory 8x slots 16x slots 16x slots 4 x 1GbE or Network 4 x GbE 4 x GbE + 2 x 10GbE 3 x 1Gbe + 1 x 10GbE or 2 x 1GbE + 2 x 10GbE 1x 3.5” SATA, non-hot-swap Internal Storage Up to 8 x 2.5” SAS, hot-swap Up to 4 x 2.5” SAS, hot-swap OR 2x 2.5” SAS Removable Media None 1x DVD-RW 1x DVD-RW Serial 1x RS-232, No USB 1x RS-232, 4x USB 1x RS-232, 4x USB PCI Express slots 1x (low profile) 3x(low profile) 3x(low profile) 1x 300W AC 2x 650W AC & DC option 2x 720W AC Power Supply Non-Redundant Redundant/Hot-Swap Redundant/Hot-Swap Fans Non-Hot-Swap 4 x Redundant/Hot-Swap 6 x Redundant/Hot-Swap Sun Internal and Approved Partners Only 14
  • 15. Sun Fire T2000/T5220/T5240 Differences Feature Sun Fire T2000 SPARC Enterprise T5220 SPARC Enterprise T5240 Form Factor 2U, 24” deep 2U, 28” deep 2U, 28” deep UltraSPARC T1 UltraSPARC T2 2x UltraSPARC T2 Plus CPU 1.0 - 1.4GHz 32 threads 1.2/1.4 GHz 64 threads 1.2/1.4 GHz 64-128 threads DDR2, 64GB MAX FB-DIMM, 64GB MAX FB-DIMM 128GB MAX Memory 16x Slots 16x Slots 32x slots 4 x GbE or Network 4x GbE 3 x GbE + 1 x 10GbE or 4x GbE + 2x 10GbE 2 x GbE + 2 x 10GbE Internal Storage 4x 2.5” SAS, hot-swap 8 x 2.5” SAS, hot-swap Up to 16 x 2.5” SAS, hot-swap Removable Media 1x DVD-ROM 1x DVD-RW 1x DVD-RW Serial 1x RS-232, 4x USB 1x RS-232, 4x USB 1x RS-232, 4x USB PCI Express slots 3x (low profile) 6x (low profile) 6x (low profile) PCI-X slots 2x (low profile) None None 2x 450W AC 2x 750W AC 2x 1100W AC/2 x1200Watt DC Power Supply Redundant/Hot-Swap Redundant/Hot-Swap Redundant/Hot-Swap Fans 3 x Redundant Hot-Swap 3 x Redundant Hot-Swap 5x Redundant/Hot-Swap Sun Internal and Approved Partners Only 15
  • 16. Front Panel Dual USB 2.0 ports Locator LED /Button DVD-RW Disk Drive Map Fault LED Top Fault LED Status LED Power Button DISK 0 DISK 1 DISK 2 DISK 3 PSU Fault LED Temp Fault LED Serial Number label Locator LED /Button Fault LED Status LED Top Fault LED Power Button PSU Fault LED Temp Fault LED DISK 1 DISK 3 DISK 5 DVD-ROM Disk Drive Map Serial Number DISK 0 DISK 2 DISK 4 DISK 6 DISK 7 Dual USB 2.0 ports DISK 3 DISK 7 DISK 12 DISK 15 DISK 2 DISK 6 DISK 11 DISK 14 DISK 1 DISK 5 DISK 9 DVD-RW DISK 0 DISK 4 DISK 8 DISK 10 DISK 13 Sun Internal and Approved Partners Only 16
  • 17. Rear Panel PCI/XAUI 0 PCI/XAUI 1 PCI 2 PSU PSU 0 PSU 1 Status LED's Chassis Status LED's Quad Gigabit Dual POSIX DB-9 and Locator Button Ethernet Ports USB 2.0 Serial Port SP SP Ports Serial Network Port Port PSU 1 PCI 3 PCI 4 PCI 5 PCI/XAUI 0 PCI/XAUI 1 PCI 2 PSU 0 Chassis PSU Status LED's Quad Gigabit POSIX DB-9 Status Dual and Locator Button Ethernet Ports USB 2.0 Serial Port LED's SP SP Ports Serial Network Port Port Sun Internal and Approved Partners Only 17
  • 18. T5140 Block Diagram CL 1RU=16 DIMMS x8 SSI x8 SSI x4 x4 PCIe x8 x8 PCIe LSI x1 Switch Switch Disk Chassis 1068E PLX 8548 PLX 8548 FPGA 1RU=4 Disks x8 x8 PCIe x8 to x4 NEPTUNE PCI Ethernet 33MHz XAUI XAUI 2 x 10/100/1000 2 x 10/100/1000/10000 32bit USB 2.0 to IDE PCI to MPC885 DVD USB ILOM USB 2.0 2.0 QUAD GbE Service Hub PHY BCM5466R Processor USB 2.0 Front Panel 0 1 2 3 USB PCIe PCIe PCIe Quad GbE Serial Network POSIX Rear Panel x16 x8 x8 Connectors Mgt Mgt Serial DB-9 Slot2 Slot1 Internal and Approved Partners Only Sun Slot0 18
  • 19. T5240 Block Diagram 2RU Memory Mezzanine Tray 2RU=16 DIMMS without Mezannine, 32 DIMMS with mezannine Option CL x8 SSI x8 SSI x4 x4 PCIe x8 x8 PCIe LSI x1 Switch Switch Disk Chassis x4 1068E PLX 8548 PLX 8548 FPGA 2RU = 8 or 16 Disks x8 x8 x8 PCIe x8 x8 x8 to x4 NEPTUNE PCI Ethernet 33MHz XAUI XAUI 2 x 10/100/1000 2 x 10/100/1000/10000 32bit USB 2.0 to IDE PCI to MPC885 DVD USB ILOM 2RU 2RU 2RU USB 2.0 2.0 QUAD GbE Service Hub PHY BCM5466R Processor USB 2.0 Front Panel 0 1 2 3 USB PCIe PCIe PCIe PCIe PCIe PCI- Quad GbE Serial Network POSIX Rear Panel x16 x8 x8 x8 x8 ex8 Connectors Mgt Mgt Serial DB-9 Slot2 Slot5 Slot1 Internal and Approved Partners Only Sun Slot4 Slot0 Slot3 19
  • 20. Internal View (T5140) Fault Remind System Configuration Service Processor Button Card (SCC)EEPROM FB0/FM0 FB1/FM0 FB0/FM0 UltraSPARC UltraSPARC UltraSPARC UltraSPARC PCIe Slot 2 T2 Plus 0 T2 Plus 0 x16(m)/x8(e) FB-DIMMs FB0/FM1 FB1/FM1 FB0/FM1 PCIe Slot 1 x8(m)/x8(e) or XAUI 1 T2 Plus 1 T2 Plus 1 Disk Chassis FB-DIMMs FB1/FM2 FB0/FM2 PCIe Slot 0 x8(m)/x8(e) or XAUI 0 Neptune PSU1 Network ASIC Power Power Board Supplies PSU0 SAS x4 cable to Power BUS Bars Memory Mezannine Connectors Disk Chassis 6 Fan Assemblies are required X4 SAS Connector 0 (cable attached) RED = +12Volts (not used on T5140) X4 SAS Connector 1 (not used in 1RU) (chassis can take up to 8) BLUE = Ground Chassis Intrusion Reed Switch (magnet on underside of lid) Sun Internal and Approved Partners Only 20
  • 21. Internal View (T5240 without Mezzanine) Fault Remind System Configuration Service Processor Button Card (SCC)EEPROM FB0/FM0 FB1/FM0 FB0/FM0 PCIe Slot 2 UltraSPARC UltraSPARC UltraSPARC UltraSPARC x8(m)/x8(e) T2 Plus 0 T2 Plus 0 x16(m)/x8(e) FB-DIMMs PCIe Slot 1 x8(m)/x8(e) x8(m)/x8(e) FB0/FM1 FB1/FM1 FB0/FM1 FB1/FM1 or T2 Plus 1 T2 Plus 1 XAUI 1 Disk Chassis FB-DIMMs PCIe Slot 0 x8(m)/x8(e) x8(m)/x8(e) or XAUI 0 FB0/FM2 FB0/FM2 Power Power PSU's Board Supplies Vertically Stacked Power BUS Bars Memory Mezannine Connectors X4 SAS Connector 0 (cable attached) 5 Fan Assemblies are required RED = +12Volts X4 SAS Connector 1 (not used in 1RU) (chassis can take up to 6) BLUE = Ground Chassis Intrusion Reed Switch (magnet on underside of lid) Sun Internal and Approved Partners Only 21
  • 22. Internal View (T5240 with Mezzanine) Mezzanine Air Fault Remind System Configuration Service Processor Guide Button Card (SCC)EEPROM FB0/FM0 FB1/FM0 FB1/FM0 PCIe Slot 2 x8(m)/x8(e) x16(m)/x8(e) FB-DIMMs PCIe Slot 1 x8(m)/x8(e) x8(m)/x8(e) FB0/FM1 FB1/FM1 FB0/FM1 FB1/FM1 or XAUI 1 Disk Chassis FB-DIMMs PCIe Slot 0 x8(m)/x8(e) x8(m)/x8(e) or XAUI 0 FB0/FM2 FB0/FM2 Power Power PSU's Board Supplies Vertically Stacked Power BUS Bars Memory Mezannine Handles 5 Fan Assemblies are required RED = +12Volts (chassis can take up to 6) BLUE = Ground Chassis Intrusion Reed Switch (magnet on underside of lid) Sun Internal and Approved Partners Only 22
  • 23. Motherboard Memory Physical Layout Chassis Chassis Front Rear Channel0/DIMM 1/Branch 1 CMP0/Branch1/Channel1/DIMM0 1 Channel0/DIMM 1/Branch 1 CMP0/Branch1/Channel1/DIMM1 3 2 Channel0/DIMM 1/Branch 1 CMP0/Branch1/Channel0/DIMM1 2 Channel0/DIMM 1/Branch 1 CMP0/Branch1/Channel0/DIMM0 1 SECOND Install ALL DIMMs in UltraSPARC Channel0/DIMM 1/Branch 1 CMP0/Branch0/Channel0/DIMM0 1 Group 2 T2 Plus 0 Channel0/DIMM 1/Branch 1 CMP0/Branch0/Channel0/DIMM1 2 12 DIMM Config Channel0/DIMM 1/Branch 1 CMP0/Branch0/Channel1/DIMM1 2 Channel0/DIMM 1/Branch 1 CMP0/Branch0/Channel1/DIMM0 1 FIRST Install ALL DIMMs in Group 1 8 DIMM Minimum UltraSPARC Channel0/DIMM 1/Branch 1 CMP1/Branch1/Channel1/DIMM0 1 Config T2 Plus 1 Channel0/DIMM 1/Branch 1 CMP1/Branch1/Channel1/DIMM1 3 Channel0/DIMM 1/Branch 1 CMP1/Branch1/Channel0/DIMM1 3 Channel0/DIMM 1/Branch 1 1 THIRD CMP1/Branch1/Channel0/DIMM0 Install ALL DIMMs in Channel0/DIMM 1/Branch 1 CMP1/Branch0/Channel0/DIMM0 1 Group 3 Channel0/DIMM 1/Branch 1 CMP1/Branch0/Channel0/DIMM1 3 16 DIMM Config Channel0/DIMM 1/Branch 1 CMP1/Branch0/Channel1/DIMM1 3 Channel0/DIMM 1/Branch 1 CMP1/Branch0/Channel1/DIMM0 1 At RR, Supported configs will be ... All DIMMs MUST be the same Size i.e 1GB, 2GB, 4GB, no mixing Fully Populate Group 1 and 2 (8 DIMMS) All DIMMs in a Branch must be the same Sun Part Number Fully Populate Groups 1, 2 and 3 (16 DIMMS) Unused DIMM locations must be occupied with DIMM Fillers Sun Internal and Approved Partners Only 23
  • 24. Mezzanine Memory Physical Layout Chassis Chassis Front Rear Channel0/DIMM 1/Branch 1 CMP0/MR0/BR1/CH1/DIMM3 4 Channel0/DIMM 1/Branch 1 CMP0/MR0/BR1/CH1/DIMM2 3 4 CMP0/MR0/BR1/CH0/DIMM2 4 CMP0/MR0/BR1/CH0/DIMM3 4 FOURTH Install ALL DIMMs in CMP0/MR0/BR0/CH0/DIMM3 4 Group 4 CMP0/MR0/BR0/CH0/DIMM2 4 24 DIMM Config CMP0/MR0/BR0/CH1/DIMM2 4 CMP0/MR0/BR1/CH1/DIMM3 4 CMP1/MR1/BR1/CH1/DIMM3 5 CMP1/MR1/BR1/CH1/DIMM2 5 CMP1/MR1/BR1/CH0/DIMM2 5 5 FIFTH CMP1/MR1/BR1/CH0/DIMM3 Install ALL DIMMs in CMP1/MR1/BR0/CH0/DIMM3 5 Group 5 CMP1/MR1/BR0/CH0/DIMM2 5 32 DIMM Config CMP1/MR1/BR0/CH1/DIMM2 5 Channel0/DIMM 1/Branch 1 CMP1/MR1/BR0/CH1/DIMM3 5 At RR, Supported configs will be ... All DIMMs MUST be the same Size i.e 1GB, 2GB, 4GB, no mixing Fully Populate Groups 1, 2, 3 , 4 and 5 (32 DIMMS) All DIMMs in a Branch must be the same Sun Part Number Unused DIMM locations must be occupied with DIMM Fillers Sun Internal and Approved Partners Only 24
  • 25. Memory Configuration Rules • Populate at least 4 DIMMS at a time • Populate by complete group only (set 1, 2, 3, 4, 5) > Groups may be 4 or 8 DIMMs, check service labels on lid • Ensure proper installation of Airflow Guides > All Configs require DIMM fillers for correct air-flow > 1RU has no Airflow Guide > 2RU has two configurations – No Mezzanine – Install Lower Air Guide – With Mezzanine – Install Lower PDB Guide and Mezzanine Guide • All DIMMS must be the same size(i.e all 1GB, 2GB or 4GB, no mixing) • In a Group all DIMMS must have the same SUN Part No. • No clocking down of memory in any config. • 8GB DIMMs will be qualified/evaluated after RR Sun Internal and Approved Partners Only 25
  • 26. Network Ports and Options XAUI 0 XAUI 1 Device NET 0 NET 1 NET 2 NET 3 XAUI 0 XAUI 1 Driver nxge0 nxge1 nxge2 nxge3 nxge0* nxge1* PCI Device PCI@300/0/8/0,0 PCI@300/0/8/0,1 PCI@300/0/8/0,2 PCI@300/0/8/0,3 PCI@300/0/8/0,0 PCI@300/0/8/0,1 NOTES All Ethernet ports provided by a single Neptune Chip on the motherboard NET 0 and NET 1 are disabled by XAUI cards if installed to take advantage of 10GbE networking * If a XAUI card is installed, the matching RJ-45 port is disabled XAUI cards take one of three current Fibre 10GbE transceivers Short Reach(SR), Long Reach(LR) and Long Reach Multimode(LRM) Copper versions of the XAUI card are expected Post-RR XAUI Cards consume the same physical space in the chassis as a PCI card, so are mutually exclusive with PCI cards in the same location Sun Internal and Approved Partners Only 26
  • 27. 10GbE XAUI Option Cards • Interface to the Neptune chip to upgrade two of its ports to 10GbE • Cards each consume a PCIe slot if installed • Attach to dedicated XAUI sockets on special risers • 10Gbe XAUI Card – SESY7XA1Z > Requires Fibre Tranceivers – 10GbE Short Reach(SR) – SESY7XT1Z – 10GbE Long Reach (LR) – SESY7XT2Z – 10GbE Long Reach multimode (LRM) – part No. TBD • Copper connector XAUI versions to follow post-RR Sun Internal and Approved Partners Only 27
  • 28. PCI Riser Cards • Various Riser Cards are used • Risers should not be moved between slots • All slots accommodate low Profile PCI-Express cards • T5140 – 25 Watts per card, 75 Watts Max (3 Slots) • T5240 – 25 Watts per card, 102 Watts Max (6 Slots) > Riser Card Mechanical and Electrical widths for T5140 and T5240 T5140 Slot 0 Slot 1 Slot 2 Only Slot x8/XAUI(m) x8(e) x8/XAUI(m) x8(e) x16(m) x8(e) T5240 Slot 1 Slot 1 Slot 2 Top Slot x8(m) x8(e) x8(m) x8(e) x8(m) x8(e) Bottom Slot x8/XAUI(m) x8(e) x8/XAUI(m) x8(e) x16(m) x8(e) Sun Internal and Approved Partners Only 28
  • 29. Disk Cage • Disk chassis is a FRU – 4 screws and disconnect cables • Contains DVD-RW/Dual USB module as a sub-FRU/CRU – Standard in all default configs – remove disk 3/7 to access release latch, pre-RR • Non-DVD module available as X-Option – Still provides Dual USB ports Remove Disk and locate latch beneath DVD Press up and pull DVD out • T5140 will be available with only a 4 disk chassis (8 disk may be post RR) > Only uses one of the x4 SAS links • T5240 will be available with 8 or 16 disk chassis > 16 Disk systems requires High-Line Power (220VAC) Sun Internal and Approved Partners Only 29
  • 30. Disk Drives • Disk drives are all 2.5” form factor • Chassis support both SAS and SATA (post-RR) • SAS Drives – 73GB @ 10K RPM – 146GB @ 10K RPM – 73GB @ 15K RPM Improved Airflow above and below – 146GB @ 15K RPM (post-RR) disks • SATA Drives – 300GB @ 5400 RPM (H2CY08) – 500GB @ 7200 RPM (end CY08) Disk LED's • New mounting bracket “Marlin” Ready to Remove > Allows better cooling in denser chassis Fault Status • Same disks as T5x20 systems Sun Internal and Approved Partners Only 30
  • 31. Disk Controller Options • T5x40 has embedded LSI1068E on the motherboard – JBOD up to 8 disks – Controls internal disks only – RAID 0 (striping) and RAID 1(mirroring), using 'radictl' – Hot-plug supported – Hot-swap in non-RAID configs is done with 'cfgadm' • Optional Extended RAID functionality cards > SPARC Drivers are available, SAS cables are being produced now > SGXPCIESAS-R-INT-Z – 8 port SAS RAID 0,1,1E,5,5EE,6,10,50,60 (depending on number of disks available) – Adaptec Card and Firmware with Intel SunRiseLake chipset – Battery Backed Write Cache (BBWC) of 256MB – BBWC battery at least 72 hours (much longer when new/fully charged) – Only for internal disks, replaces cables to route to standard disk chassis > SGXPCIESAS-R-EXT-Z – External port version, for external disk arrays only (no internal ports) > Not available for T5440 due to chassis design and only 4 disk capacity Sun Internal and Approved Partners Only 31
  • 32. Fans and Cooling • T5140 Unused Fan slots can be populated, but not recommended, fans will run and wear, so not a great way of keeping spares.... > Requires 6 Fan modules – Main System Cooling FBD1 FBD0 PSU's FM3 FM3 FM3 – FANBD0/FM0 Disk Chassis Disk Chassis FBD1 – FANBD0/FM1 FBD0 FM2 FM2 FM2 – FANBD0/FM2 – FANBD1/FM0 FBD1 FBD0 Motherboard FM1 FM1 FM1 – FANBD1/FM1 – FANBD1/FM2 FBD1 FBD0 FM0 FM0 FM0 – No Modules in FM3 • T5240 Back Front > Requires 5 Fan Modules – Main system Cooling PSU's FBD1 FBD0 FM2 FM2 FM2 FM2 – FANBD0/FM0 Disk Chassis Disk Chassis – FANBD0/FM1 FBD1 FBD0 FM1 FM1 FM1 FM1 – FANBD0/FM2 Motherboard – FANBD1/FM0 – FANBD1/FM1 FBD1 FBD0 FM0 FM0 FM0 – No Modules in FANBD1/FM2 Sun Internal and Approved Partners Only 32
  • 33. Fans modules and boards • Fans are speed controlled by the Service Processor • Each fan has an Amber FAULT LED – if lit the fan module is faulty • 1RU modules – 2 Fans at 15K RPM Max. Fan Fault • 2RU modules Amber LED – 2 Fans at 12K RPM Max Lit if fan faulty • Monitored through ILOM/IPMI/Web Vibration Absorbing Silicon Dampers Sun Internal and Approved Partners Only 33
  • 34. Power Supplies • PSU's are high efficiency • Output 12V (and 3.3v standby) PSU LED's • Most DC-DC conversion done in MBD Ready to Remove Fault • Shared with Doradi/o, Tucani/a AC Present • Integrated Fan • T5140 > Side-by-Side > AC 720Watts • T5240 > Vertically Stacked > 1100Watts > DC 1200 Watts option coming post-RR > DC or AC, no sharing > BEWARE... – Same form factor as SunFire X4200 PSU's ... DO NOT MIX – 1.4Ghz and 16 Disk configs require 220VAC (called “High Line Power”) Sun Internal and Approved Partners Only 34
  • 35. Rack Mounting Options • Two Rack mounting options are available.. • Standard Rack Mount (4 post)SESY9RK1Z > Standard configs contain this kit – ATO : SESY9RK1Z, X-ATO : SESY9RK1Z • Tool-less Rack Kit (4 post) > Optional kit, purchased seperately > Snaps into most 3rd party Racks > Requires no tools to fit or remove – ATO : SESY9RK2Z, X-ATO : SESX9RK2Z Sun Internal and Approved Partners Only 35
  • 36. Solaris for Sun SPARC Enterprise T5x40 • T5x40 servers will require Solaris10 8/07 (update 4) with patches > A Patch CD is supplied in the box – Mandatory patches = 127111-08,126434-05,125416-05 – Available patches = 124235-02, 125369-13,125476-02,127111-07 – Likely to be out of date, so customers should check SunSolve... • This incorporates several specific UltraSPARC T2/T2 Plus optimizations and for CMT servers in general • Also includes some specific T5x40 optimisations > UltraSPARC T2 Plus MPO optimisations > nxge driver tweaks for 10GbE devices > MMU DMA relaxed scheduling > LDOMs pre-install upgrade to version 1.0.2 (US T2 Plus support) Sun Internal and Approved Partners Only 36
  • 37. Solaris FMA • Now aware of CPU Core offlining • PCIe Fabric diagnostics improved • Crypto Unit offlining • Neptune awareness (though XAUI's not diagnosed) • POST memory CE tolerance improved • FRU identity info improved in fault reports (part/ser #) • Diagnostic Engines (DE) – Existing DE have been extended for T5x40 – New Eversholt DE used for HostBridge, PCIe diagnostics • Limitations... – Can't isolate Uncorrectable Errors to a single DIMM – PCIe riser cards not in topology – XAUI card and XFP not in the topology – SouthBridge chip is not diagnosed at this time (DVD, USB,...) – IO Expansion box is not diagnosed via FMA Sun Internal and Approved Partners Only 37
  • 38. ILOM Features at a Glance • Hardware Control, Inventory, Monitoring • Host Configuration and Administration • SP Configuration and Administration • Logging, Auditing and Alerting • Authentication : – LDAP, RADIUS, Active Directory, Local Users • Services : – SSH, HTTP(S), NTP, Syslog, SMTP • Out-of-Band – Via Serial port, or dedicated Ethernet port • In-Band – Via Host OS, firmware upload, Explorer, Syslog Sun Internal and Approved Partners Only 38
  • 39. ILOM – Industry Standard Manageability • ILOM enables Sun systems to be easily integrated into third party management infrastructures • Key functionality > IPMI 2.0 > SNMP V1, V2c, V3 > SSH 2.0 > LDAP, RADIUS & MS Active Directory authentication > Browser UI, SMASH DMTF CLP + ALOM style CLI • NOTE : No RKVMS functionality like Galaxy ILOM > No Java plugin required • Browsers tested include, these base versions an later releases – Mozilla 1.7 on Solaris 10, IE 6.0 on W2K Server, Firefox 1.0 and 1.5 on W2K server Sun Internal and Approved Partners Only 39
  • 40. ILOM – Industry Standard Manageability • Identical to ILOM 2.0 for T5x20 • Default user is 'root' with password 'changeme' > Use for ILOM WEB GUI access and SSH access and IPMI • The ALOM 'admin' user is not defined by default, create this user with an ALOM CLI • Lost 'root' password and ILOM config is reset using jumpers > T5140/T5240 - Motherboard Jumper J10401 (short pins 1-2) • Note... 'sunservice' user shares the password of the 'root' user ONLY FOR SERVICE ACCESS* • Passwords must be 8 to 16 chars (used to be max 8) • Max of 10 users allowed (used to be 16) Sun Internal and Approved Partners Only 40
  • 41. ILOM Common Tasks • Setting up an ALOM 'admin' user from the ILOM CLI > SUNSP00144F4641BD login: root Password: changeme Waiting for daemons to initialize... Daemons ready Sun(TM) Integrated Lights Out Manager Version 2.0.4.0 Copyright 2007 Sun Microsystems, Inc. All rights reserved. Use is subject to license terms. Warning: password is set to factory default. ->create /SP/users/admin role=Administrator cli_mode=alom Creating user... Enter new password: ******** Enter new password again: ******** Created /SP/users/admin2 -> exit SUNSP00144F4641BD login: admin Password: ******** Waiting for daemons to initialize... Daemons ready Sun(TM) Integrated Lights Out Manager Version 2.0.4.0 Copyright 2007 Sun Microsystems, Inc. All rights reserved. Use is subject to license terms. sc> Sun Internal and Approved Partners Only 41
  • 42. ILOM Common Tasks • Setting up ILOM IP configuration from the ILOM CLI > SUNSP00144F4641BD login: root Password: changeme Waiting for daemons to initialize... Daemons ready Sun(TM) Integrated Lights Out Manager Version 2.0.4.0 Copyright 2007 Sun Microsystems, Inc. All rights reserved. Use is subject to license terms. Warning: password is set to factory default. -> set /SP/network state=enabled Set ’state’ to ’enabled’ -> set /SP/network pendingipaddress=10.8.31.163 Set ’pendingipaddress’ to ’10.8.31.163’ -> set /SP/network pendingipdiscovery=static Set ’pendingipdiscovery’ to ’static’ -> set /SP/network pendingipnetmask=255.255.252.0 Set ’pendingipnetmask’ to ’255.255.252.0’ -> set /SP/network pendingipgateway=10.8.31.248 Static IP Set ’pendingipgateway’ to ’10.8.31.248’ configuration -> set /SP/network commitpending=true Set ’commitpending’ to ’true’ -> -> set/SP/pendingipdiscovery=dhcp Set ’pendingipdiscovery’ to ’dhcp’ -> set /SP/network commitpending=true Set ’commitpending’ to ’true’ -> Dynamic IP (DHCP) configuration Sun Internal and Approved Partners Only 42
  • 43. ILOM IPMI functionality • IPMI is a widely used management protocol for x86 servers • ... But its new for SPARC boxes... • Download the required tools from > The Solaris Supplemental CD (an older binary package) > Latest is available at http://ipmitool.sourceforge.net – Binary packages (usually older versions) are available for Solaris x86 and SPARC, as well as Linux, Windows, Mac...etc > There is a Blueprint available from Sun also (mainly x64 centric, but applies to SPARC now too) – http://www.sun.com/blueprints/0107/820-1011.pdf -bash-ventus2$ /opt/ipmitool/bin/ipmitool -U root -P changeme -H 10.10.10.10 sdr /MB/V_+1V0_VDD | 1.01 Volts | ok /MB/V_+3V3_STBY | 3.36 Volts | ok Get the Sensor /MB/V_+3V3_MAIN | 3.36 Volts | ok Data /MB/V_+5V0_VCC | 4.97 Volts | ok Repository /MB/V_+12V0_MAIN | 12.16 Volts | ok .. .. -bash-ventus2$ /opt/ipmitool/bin/ipmitool -U root -P changeme -H 10.10.10.10 sunoem sbled set /SYS/LOCATE on /SYS/LOCATE | ON Set the System -bash-ventus2$ Locator LED flashing Sun Internal and Approved Partners Only 43
  • 44. ILOM Common Tasks • Logging into the ILOM Web GUI • Point Web Browser at the IP address of the ILOM > Will automatically redirect to a secure HTTPS port > Best to disable any Web Proxies for best performance > Make sure port 80, 443 are open on any firewall • Log in as any defined user, default Administration user is 'root' Sun Internal and Approved Partners Only 44
  • 45. ILOM/ALOM Common Tasks • A Tour of the ILOM Web GUI • GUI provides ways to set up IP address configurations for ILOM • Configure additional ILOM/ALOM users • Access Sensor Readings • Control System configurations • Carry out firmware updates. • etc.... Sun Internal and Approved Partners Only 45
  • 46. ALOM 2.0 vs. 1.4 CLI Differences • Default CLI appearance is ILOM – User is 'root' – Must create an 'admin' Administrator user with the ALOM CLI • Flashupdate in new ALOM expects a TFTP server not an FTP server • ALOM IP address changes now active only after running ... – 'setsc netsc_commit true ' – Previously changes were active only after SC reset – DHCP is enabled by default • View firmware versions with – 'showhost version ' sc> showhost version Sun System Firmware 7.0.0_build_13 2007/08/10 23:44 • Only Admin and Operator roles Host flash versions: Hypervisor 1.5.0.build_13**PROTOTYPE** 2007/08/10 22:54 OBP 4.27.0.build_04***PROTOTYPE BUILD*** 2007/08/10 13:25 are defined Sun Fire[TM] Huron POST 4.27.0.build_04***PROTOTYPE BUILD*** 2007/08/10 13:51 Sun Internal and Approved Partners Only 46
  • 47. ALOM backward Compatibilty CLI • Uses ALOM-CMT 1.2 for a base feature set • Includes ALOM-CMT 1.4 features... > break -d > Host Watchdog Timer > Bootmode LDOMs awareness > Forward SP events to Hot/Solaris syslog via inband channel Sun Internal and Approved Partners Only 47
  • 48. Logical Domains 1.0.2 Features Release in Q1CY08 aligned with UltraSPARC T2 Plus launch • UltraSPARC T2 Plus Platform Support > 128 domains supported at RR – 256 domains work on T5440, may be qualified later, requires Solaris fixes • Feature Set very similar to 1.0.1 • I/O domain can reboot while the other domains keep running > Dependant domains would wait for IO transactions to complete • LDoms SNMP MIB > Modeled after industry standard DMTF CIM (Common Information Model) > Running on control domain to enable remote SNMP monitoring • Domain minimization support > Minimal/reduced Solaris installation > Base minimal packages plus optional ones for guest, control, I/O or service domains Sun Internal and Approved Partners Only 48
  • 49. Logical Domains 1.0.2 Requirements • Solaris 10 08/07 (update 4) and required patches • Systems firmware version – T5x40 Firmware 7.1.0 = SP FW 2.0.4.20+ – T5x20/SB6320 Firmware 7.0.4+ = SP FW 2.0.4.0+ – T2000/T1000/T6300/Pelton Firmware 6.5.x • SUNWldm.v LDOMs Manager Package – Version 1.0.2 Sun Internal and Approved Partners Only 49
  • 50. CRU/FRU List - T5140 • Lots shared with other Jake and Elwood systems Item Description FRU/CRU Disk Backplane 4 drive Disk Backplane to support 4 Drives only FRU Disk Backplane 8 drive Disk Backplane to support 8 Drives (post -RR) FRU Fan Module 1U Dual Fan module, 4 populated in system CRU Fan Board 1U Fan connector board to accommodate Fan Modules, 2 per system FRU DVD Assembly DVD Assembly including front USB board FRU Paddle board 1U Conection between PDB, fan boards and Disk Backplane FRU PDB 1U Power distribution board, contains master chassis serial number FRU PSU 1U Power supply (720 Watts) CRU X8 &XAUI, 1U PCIe Riser PCI Riser assembly for left and centre motherboard slots CRU x16 1U PCIe Riser PCI Riser for right motherboard slot CRU Rack mount kit (requires tools) Rack mount kit CRU Rack Mount Kit (tooless) Rack mount kit, no tools required for installation CRU CMA Cable management arm CRU Bus Bars Power Bus Bars between PDB and Motherboard FRU PDB to MB Ribbon Cable Ribbon cable for control connections between PDB abd Motherboard FRU Light pipe kit Light pipe assemblies for left and right of disk cage FRU Motherboard assembly Motherboard assembly, part no varies depending on Core count FRU DIMMs FBDIMMs (three different part numbers for 1GB, 2GB, 4GB) CRU XAUI board optical/copper XAUI Adapter card (two different parts for copper/optical) CRU XFP module XFP GBIC module for use in XAUI cards (three different parts SR, HR, HRMM) CRU Battery Battery backup for NVRAM of Service Processor CRU HDD 73GB/146GB SAS Hard Disk drive, different part numbers for capacities CRU System Configurations PROM System Configuration PROM FRU Maramba Cable Kit SAS Cable kit FRU Sun Internal and Approved Partners Only 50
  • 51. CRU/FRU List - T5240 • Lots shared with other Jake and Elwood systems Item Description FRU/CRU Disk Backplane 16 drive Disk Backplane to support 16 Drives only FRU Disk Backplane 8 drive Disk Backplane to support 8 Drives only FRU Fan Module 2U Dual Fan module, 3 populated in system CRU Fan Board 2U Fan connector board to accommodate Fan Modules, 2 per system FRU DVD Assembly DVD Assembly including front USB board FRU Paddle board 2U Connection between PDB, fan boards and Disk Backplane FRU PDB 2U Power distribution board, contains master chassis serial number FRU PSU 2U Power supply (1100 Watts) CRU X8,X8, XAUI, 2U PCIe Riser PCI Riser assembly for left and centre motherboard slots CRU X8, x16 2U PCIe Riser PCI Riser for right motherboard slot CRU Rack mount kit (requires tools) Rack mount kit CRU Rack Mount Kit (tooless) Rack mount kit, no tools required for installation CRU CMA Cable management arm CRU Bus Bars Power Bus Bars between PDB and Motherboard FRU PDB to MB Ribbon Cable Ribbon cable for control connections between PDB abd Motherboard FRU Light pipe kit Light pipe assemblies for left and right of disk cage FRU Motherboard assembly Motherboard assembly, part no varies depending on Core count FRU DIMMs FBDIMMs (three different part numbers for 1GB, 2GB, 4GB) CRU XAUI board optical/copper XAUI Adapter card (two different parts for copper/optical) CRU XFP module XFP GBIC module for use in XAUI cards (three different parts SR, HR, HRMM) CRU Battery Battery backup for NVRAM of Service Processor CRU HDD 73GB/146GB SAS Hard Disk drive, different part numbers for capacities CRU System Configurations PROM System Configuration PROM FRU Maramba Cable Kit SAS Cable kit FRU Sun Internal and Approved Partners Only 51
  • 52. Option Parts List for T5140/T5240 Part Number Option Description Available SECY9PS41Z AC PSU 1RU (720 Watts) RR SEDY9PS51Z AC PSU 2RU (1100 Watts) RR - DC PSU 2RU (1200Watts) post-RR SESY2A1Z 2GB Memory (2x1GB) RR SESY2B1Z 4GB memory (2x2GB) RR SESY2C1Z 8GB Memory (2x4GB) RR SESY9FF1Z FB-DIMM Filler panel RR SEUY2MM1Z Memory Mezzanine Assembly 2U only RR SEU9AD1Z Memory Mezzanine Air Duct RR SETY9BA1Z 4 Disk Backplane for 1U RR SETY9BB1Z 8 Disk Backplane for 1U post-RR SEUY9BB1Z 8 Disk Backplane for 2U RR SEUY9BC1Z 16 Disk Backplane for 2U (High Line only (220VAC) RR SESY3A11Z 73GB, 10KRpm 2.5” SAS Drive RR SESY3C11Z 146GB, 10KRpm 2.5” SAS Drive RR SESX3A21Z 73GB, 15KRpm, 2.5” SAS Drive RR - SATA Drives (300,500GB) post-RR SESY9MF1Z HDD Filler Panel RR SESY9DV1Z DVD, 8X RW, Slot Load RR SESY9RK1Z Slide Rail Kit, requires screwdriver (1RU and 2RU) RR SESY9RK2Z Slide Rail Kit, Tool-less (1RU and 2RU) RR Sun Internal and Approved Partners Only 52
  • 53. Option Parts List for T5140/T5240 (cont..) Part Number Option Description Avialable Max no.(1RU/2RU) SG-PCIE1FC-QF4 Qlogic, 4Gb, PCI-E Single Port RR 3/6 SG-PCIE2FC-QF4 Qlogic, 4Gb, PCI-E Dual Port RR 3/6 SG-PCIE1FC-EM4 Emulex, 4Gb, PCI-E Single Port RR 3/6 SG-PCIE2FC-EM4 Emulex, 4Gb, PCI-E Dual Port RR 3/6 SG-PCIE2SCSI-U320Z U320 SCSI, PCI-E Dual Port RR 3/6 SG-PCIE8SAS-E-Z SAS, 8 Port, PCI-E RR 3/6 SGCPCIESAS-R-INT-Z SAS, 8 Port, RAID, PCI-E, External Drive Controller RR 1/1 SGCPCIESAS-R-EXT-Z SAS, 8 Port, RAID, PCI-E, External Drive Controller RR 1/1 SECX9SA1Z Cable X-option for T5140 RR 1/1 SECX9SA2Z Cable X-option for T5240 RR 1/1 7281A-2 Northstar Dual port GigE MMF Low profile PCI-E RR 3/6 7280A-2 Northstar Dual port GigE UTP Low profile PCI-E RR 3/6 1236A-Z Infiniband HBA, Dual 4x ports, PCI-E RR 3/6 4447A-X Atlas Quad Port, GigE Copper, PCI-E (up to 3/6) RR 3/3 X1027A-Z Atlas Dual Port, 10GigE, PCI-E RR 3/3 X5558A Tranceiver 10GE SR XFP (XAUI/Atlas) RR - X5560A-Z Tranceiver 10GE LR XFP (XAUI/Atlas) RR - X3000A XVR-300, PCI-E x8 Graphics cards TBD 1/1 X4240A XVR-300, PCI-E x16 Graphics cards, requires 605-4668-04 cable TBD 1/1 SESY7XA1Z 10GbE XAUI card RR 2/2 TBD 10GbE XAUI Copper 10g Base-T TBD 2/2 X6000A Sun Crypto Accelerator 6000 RR 1/ 2 Sun Internal and Approved Partners Only 53