Technical data sheet heat exchanger BOUL

Technical data sheet heat exchanger BOUL. Supply and exhaust ventilation unit with heat recovery BOUL RECUPERATORS

ENERGY SAVING SUPPLY & EXHAUST VENTILATION UNIT
WITH HEAT RECOVERY
TECHNICAL DATA SHEET
PIONEER 30 PIONEER 30+ PIONEER 60
PIONEER 60+ PIONEER Evolution
Supply and exhaust ventilation unit
with heat recovery
TECHNICAL DATA SHEET / MAITENANCE MANUAL
1. General data.
1.1. Supply and exhaust ventilation unit with heat recovery (hereafter referred to as
recuperator) is an electric device manufactured as a decentralized ventilation monoblock,
which does not require connecting ducts and is designed to create and maintain a
comfortable microclimate in rooms of various functional purposes.
1.2. The recuperator circulates air between the room and the outdoor air environment
(street), while being located in the outer wall of the building (in-wall installation).
1.3. The efficiency of the ventilation device is achieved due to the application of high-quality
and environmentally friendly components, which allows it to be highly rationally used for
household objects, as well as facilities with increased requirements for sanitary conditions:
apartments, private houses, cottages, offices, rooms for various purposes, educational
institutions, kindergartens, workshops, stores, production premises, etc.
1.4. Recuperator countercurrent aluminium heat exchanger has high coefficient of heat
exchange efficiency in both directions. The technical solution of the recuperator operation is
based on the principle of heat exchange between the exhaust air flow from the room and
the supply air from the street. In winter, warm and exhaust extract air transfers its heat to
the supply air, heating it through the plates of the heat exchanger installed in the ventilation
device. In fact, heat is recovered from the extract air, which effectively heats the fresh air
supplied from the street. The heat exchanger of the device is designed in such a way that
oppositely directed flows do not mix, which can significantly increase the efficiency of
recuperation. In summer, the recuperator significantly reduces the temperature of the
supply air from the outside, working in tandem with the indoor air conditioner. This process
is directly opposite to the winter mode: the cooler air stream removed from the room cools
partially the supply air.
1.5. In addition to high-efficiency heat exchange, the recuperator allows to reduce the
amount of moisture in the room, removing it together with exhaust air. This helps to prevent
the appearance of damp in the room, condensate on the windows, fungus and mold on the
walls.
1.6. "BOUL" supply and exhaust recuperators are produced by the manufacturer in various
modifications, differing mainly in productive capacity (air exchange m³/ hour), the number of
operating modes and the principle of the unit control.
1.7. “BOUL” recuperators are manufactured in compliance with the requirements of TU U
27.5-39682956-002: 2021.
2. Main technical characteristics.
2.1. The devices are connected to the electrical network with parameters of 110-240V,
60/50 Hz.
2.2. The devices are equipped with fans with power supply 12V DC.
2.3. The productive capacity of the device (if such a parameter is provided by a particular
model) is controlled via the remote control.
2.4. The main dimensions of the device: see the Figure above.
Indoor view
(from the room):
Outdoor view
(from the street):
Side view:
3. "BOUL" recuperators model range.
- The manufacturer reserves the right to change the color of the fan blades. It is black by
default. Additional accessories are presented in the manufacturer's advertising catalogues.
- The manufacturer has the right to expand the range of models, complementing the basic
models presented above with minor characteristics. Such changes will have the prefix "+"
(Pioneer 30 +, Pioneer 60 +, etc.).
- The device is equipped with an automatic valve on the exhaust channel and a mechanical
valve on the supply channel. Control of the valve of the supply channel is mechanical. By
turning the control wheel clockwise as far as it will go, the user has the option of blocking the
supply channel.
- Insulation class: II.
- Protection degree: IP24.
- The established operation life of the system: 10 years.
- Warranty period: 24 months.
- Operation of the unit: at the temperatures from -30°C to + 40°C.
Model name Pioneer 30 Pioneer 30+ Pioneer 60 Pioneer 60+ Evolution
Diameter of
working module
with insulation, mm
170 170 170 170 170
Mounting hole
diameter, mm
182 182 182 182 182
Recommended
space area, m² (at
residential ceiling
height)
up to 12 up to 12 up to 25-30 up to 25-30 up to 40
Number of people
in the room
up to 2 up to 3 up to 4 up to 4 up to 5
Air volume
(m³/hour)
up to 30 up to 30 up to 65 up to 65 up to 110
Number of
operating modes
1: Recovery (both
supply and
exhaust
simultaneously
1: Recovery (both
supply and
exhaust
simultaneously
1: Recovery (both
supply and
exhaust
simultaneously
3: Recovery,
Supply,
Exhaust
4: Recovery,
Supply,
Exhaust,
Smooth speed
adjustment
Power consumption
(W/h)
0-7 0-7 0-15 0-15 10-30
Control Manual Remote control Remote control Remote control Remote control
Noise level, dB 18-20 20-22 22-24 22-24 28-36
Device weight, kg 3,2 3,2 3,5 3,5 3,5
Packing box size,
mm
720*260*260 720*260*260 720*260*260 720*260*260 720*260*260
4. Installation.
"BOUL" supply and exhaust ventilation system with heat recovery is a monoblock that is
ready to use in accordance with design and layout tasks and conditions. The system is
mounted into the hole of the corresponding diameter (182 mm) in the upper part of the wall,
which borders the street, at a distance of at least 100-150 mm from the ceiling or wall.
The inclination towards the street is implemented constructively in the device. There is no
need to make a hole in the wall at an angle (!).
The working module of the ventilation system is mounted into the hole on the seal (Fig.1).
Fig.1. Mounting “BOUL” into the hole:
The length of the working module must correspond to the thickness of the wall in which the
installation is carried out (minimum 440 mm). To ensure the correct operation of the system,
it is necessary that its housing, which faces the street, protrudes 1-2 cm beyond the wall till of
the outlet flow canals (Exhaust air).
Fig.2. Hole preparation:
Other preparatory work includes preparation of the
hole for the installation of the switch and grooves for
the electrical network between the system, the
switch and the place where the system is connected
to the power source.
CONNECTION
of the recuperator to the electrical network, system control from the remote.
Fig.3. Connection of recuperator to the electrical network in case of its
regulation by remote control unit.
Disconnect the electricity supply to the electrical network to which the ventilation system will
be connected.
Attention! Make sure that the power supply is actually cut off!
The ventilation system is connected to a stationary electric network with 110-240V.
Connection of the ventilation system to the mains is provided by an electric cable, which goes
from the working module (standard configuration). If the electrical network is not connected
to the mounting hole, the electrical cable from the recuperator should be connected to the
mains in the junction box as shown in Fig.3. Connect the contact terminals 1 and 2 in parallel,
or install the electrical connector on the cable that meets the above parameters for fast
connection and disconnection of electrical devices. Electrical connectors are not included in
standard configuration. If the cable of the stationary network was previously connected to
the mounting hole, then the power is connected to the cable of the working module in close
proximity to the recuperator housing. Сut the recuperator electric cable to the length that is
convenient for electrical connection.
All electrical cables used in the installation must be 0.5-0.75 mm² in section. The operation of
the system is regulated by remote control unit (except BOUL «Pioneer 30» model). Remote
control unit controls the operation of fans built into the housing of the ventilation system
≈110-240V
(turns on, regulates, turns off).
Recuperators BOUL are adapted to the existing electrical network in automatic mode without
the use of software. This reduces significantly the noise parameters of the equipment and
allows to provide the noise characteristics of the ventilation system declared in the technical
data sheet.
Attention! After the ventilation system is connected to the mains, it is necessary to:
1. Supply power to the system.
2. Check fan operation in different modes, using control options.
5. Operation. Maintenance.
5.1. Do not block and obscure the device with interior objects.
5.2. While exploitation, it is necessary to purge the recuperator once a year (possibly by
connecting a hose to the back of the vacuum cleaner). But before it, first remove the interior
part of the recuperator by pulling it towards you.
6. Transportation. Storage.
6.1. Transportation of the ventilation unit in its original packaging is allowed by any type of
transport that ensures its safety from mechanical damage.
6.2. Ventilation units must be stored indoors or under a canopy and must be protected from
moisture and corrosive chemicals.
7. Warranty.
Warranty exploitation period, subject to the requirements of this passport for storage,
transportation, installation and operation, is established for 2 years from the date of commissioning
of the device, but not more than 2.5 years from the date of shipment from the manufacturer.
WARRANTY CARD № ________________
Seller:
Buyer:
Equipment name:
Quantity:
Warranty support period: 24 months
I agree with the warranty condition Sale date
___________________________ (Buyer's full name) _______ 20___
___________________________ (Buyer's signature)
Selling company __________________________________
Seller's full name ___________________________________________ Stamp
21A, Avtostradna Naberezhna, Kharkiv, 61038, Ukraine
tel.: +38 (057) 780-03-28; +38 (067) 421 46 86
E-mail: trade@boul.com.ua
Web: www.boul.com.ua

Recommandé

Vento expert a50_1_wen par
Vento expert a50_1_wenVento expert a50_1_wen
Vento expert a50_1_wenOliverh Kalprit
197 vues4 diapositives
Ventoergoa251proen par
Ventoergoa251proenVentoergoa251proen
Ventoergoa251proenOliverh Kalprit
41 vues4 diapositives
Ventilation system par
Ventilation systemVentilation system
Ventilation systemNoorule Inie Osman
109.7K vues22 diapositives
Rittal - İklimlendirme ve Soğutma Ürünleri 144 161 par
Rittal - İklimlendirme ve Soğutma Ürünleri 144 161 Rittal - İklimlendirme ve Soğutma Ürünleri 144 161
Rittal - İklimlendirme ve Soğutma Ürünleri 144 161 erdinc klima
634 vues18 diapositives
Smart Fans for Smarter White Good par
Smart Fans for Smarter White GoodSmart Fans for Smarter White Good
Smart Fans for Smarter White GoodKarl Kruse GmbH & Co.KG
82 vues4 diapositives
Mechanical ventilation par
Mechanical ventilationMechanical ventilation
Mechanical ventilationAnupama Krishnan
31 vues10 diapositives

Contenu connexe

Similaire à Technical data sheet heat exchanger BOUL

Building services.pptx par
Building services.pptxBuilding services.pptx
Building services.pptxpriyanka415514
23 vues64 diapositives
AIR CONDITIONING par
AIR CONDITIONINGAIR CONDITIONING
AIR CONDITIONINGNavedKhan133
266 vues24 diapositives
window natural ventilation brochure par
window natural ventilation brochurewindow natural ventilation brochure
window natural ventilation brochureAirtherm Engineering
520 vues8 diapositives
Xenon lamp-aging-test-chamber par
Xenon lamp-aging-test-chamberXenon lamp-aging-test-chamber
Xenon lamp-aging-test-chamber世满 江
21 vues6 diapositives
Xenon lamp-aging-test-chamber par
Xenon lamp-aging-test-chamberXenon lamp-aging-test-chamber
Xenon lamp-aging-test-chamber世满 江
18 vues6 diapositives
Presentation emb and industrial ventilation par
Presentation emb and industrial ventilationPresentation emb and industrial ventilation
Presentation emb and industrial ventilationjkborade
669 vues48 diapositives

Similaire à Technical data sheet heat exchanger BOUL(20)

Xenon lamp-aging-test-chamber par 世满 江
Xenon lamp-aging-test-chamberXenon lamp-aging-test-chamber
Xenon lamp-aging-test-chamber
世满 江21 vues
Xenon lamp-aging-test-chamber par 世满 江
Xenon lamp-aging-test-chamberXenon lamp-aging-test-chamber
Xenon lamp-aging-test-chamber
世满 江18 vues
Presentation emb and industrial ventilation par jkborade
Presentation emb and industrial ventilationPresentation emb and industrial ventilation
Presentation emb and industrial ventilation
jkborade669 vues
Presentation industrial ventilation roda par Eeu SC
Presentation industrial ventilation rodaPresentation industrial ventilation roda
Presentation industrial ventilation roda
Eeu SC367 vues
Img gas-water-heater-user-manuel-pdoc-975742227286282959 par Daxom/Navidens
Img gas-water-heater-user-manuel-pdoc-975742227286282959Img gas-water-heater-user-manuel-pdoc-975742227286282959
Img gas-water-heater-user-manuel-pdoc-975742227286282959
Daxom/Navidens16 vues
Rittal - İklimlendirme ve Soğutma Ürünleri 024 075 par erdinc klima
Rittal - İklimlendirme ve Soğutma Ürünleri 024 075Rittal - İklimlendirme ve Soğutma Ürünleri 024 075
Rittal - İklimlendirme ve Soğutma Ürünleri 024 075
erdinc klima1.4K vues
Ventilation par Dantherm
VentilationVentilation
Ventilation
Dantherm1.6K vues

Dernier

Ansari: Practical experiences with an LLM-based Islamic Assistant par
Ansari: Practical experiences with an LLM-based Islamic AssistantAnsari: Practical experiences with an LLM-based Islamic Assistant
Ansari: Practical experiences with an LLM-based Islamic AssistantM Waleed Kadous
11 vues29 diapositives
Integrating Sustainable Development Goals (SDGs) in School Education par
Integrating Sustainable Development Goals (SDGs) in School EducationIntegrating Sustainable Development Goals (SDGs) in School Education
Integrating Sustainable Development Goals (SDGs) in School EducationSheetalTank1
11 vues29 diapositives
MongoDB.pdf par
MongoDB.pdfMongoDB.pdf
MongoDB.pdfArthyR3
51 vues6 diapositives
Global airborne satcom market report par
Global airborne satcom market reportGlobal airborne satcom market report
Global airborne satcom market reportdefencereport78
7 vues13 diapositives
Unlocking Research Visibility.pdf par
Unlocking Research Visibility.pdfUnlocking Research Visibility.pdf
Unlocking Research Visibility.pdfKhatirNaima
11 vues19 diapositives
Design_Discover_Develop_Campaign.pptx par
Design_Discover_Develop_Campaign.pptxDesign_Discover_Develop_Campaign.pptx
Design_Discover_Develop_Campaign.pptxShivanshSeth6
55 vues20 diapositives

Dernier(20)

Ansari: Practical experiences with an LLM-based Islamic Assistant par M Waleed Kadous
Ansari: Practical experiences with an LLM-based Islamic AssistantAnsari: Practical experiences with an LLM-based Islamic Assistant
Ansari: Practical experiences with an LLM-based Islamic Assistant
M Waleed Kadous11 vues
Integrating Sustainable Development Goals (SDGs) in School Education par SheetalTank1
Integrating Sustainable Development Goals (SDGs) in School EducationIntegrating Sustainable Development Goals (SDGs) in School Education
Integrating Sustainable Development Goals (SDGs) in School Education
SheetalTank111 vues
MongoDB.pdf par ArthyR3
MongoDB.pdfMongoDB.pdf
MongoDB.pdf
ArthyR351 vues
Unlocking Research Visibility.pdf par KhatirNaima
Unlocking Research Visibility.pdfUnlocking Research Visibility.pdf
Unlocking Research Visibility.pdf
KhatirNaima11 vues
Design_Discover_Develop_Campaign.pptx par ShivanshSeth6
Design_Discover_Develop_Campaign.pptxDesign_Discover_Develop_Campaign.pptx
Design_Discover_Develop_Campaign.pptx
ShivanshSeth655 vues
GDSC Mikroskil Members Onboarding 2023.pdf par gdscmikroskil
GDSC Mikroskil Members Onboarding 2023.pdfGDSC Mikroskil Members Onboarding 2023.pdf
GDSC Mikroskil Members Onboarding 2023.pdf
gdscmikroskil68 vues
2023Dec ASU Wang NETR Group Research Focus and Facility Overview.pptx par lwang78
2023Dec ASU Wang NETR Group Research Focus and Facility Overview.pptx2023Dec ASU Wang NETR Group Research Focus and Facility Overview.pptx
2023Dec ASU Wang NETR Group Research Focus and Facility Overview.pptx
lwang78188 vues
REACTJS.pdf par ArthyR3
REACTJS.pdfREACTJS.pdf
REACTJS.pdf
ArthyR337 vues
Design of Structures and Foundations for Vibrating Machines, Arya-ONeill-Pinc... par csegroupvn
Design of Structures and Foundations for Vibrating Machines, Arya-ONeill-Pinc...Design of Structures and Foundations for Vibrating Machines, Arya-ONeill-Pinc...
Design of Structures and Foundations for Vibrating Machines, Arya-ONeill-Pinc...
csegroupvn13 vues
Créativité dans le design mécanique à l’aide de l’optimisation topologique par LIEGE CREATIVE
Créativité dans le design mécanique à l’aide de l’optimisation topologiqueCréativité dans le design mécanique à l’aide de l’optimisation topologique
Créativité dans le design mécanique à l’aide de l’optimisation topologique
BCIC - Manufacturing Conclave - Technology-Driven Manufacturing for Growth par Innomantra
BCIC - Manufacturing Conclave -  Technology-Driven Manufacturing for GrowthBCIC - Manufacturing Conclave -  Technology-Driven Manufacturing for Growth
BCIC - Manufacturing Conclave - Technology-Driven Manufacturing for Growth
Innomantra 20 vues

Technical data sheet heat exchanger BOUL

  • 1. ENERGY SAVING SUPPLY & EXHAUST VENTILATION UNIT WITH HEAT RECOVERY TECHNICAL DATA SHEET PIONEER 30 PIONEER 30+ PIONEER 60 PIONEER 60+ PIONEER Evolution
  • 2. Supply and exhaust ventilation unit with heat recovery TECHNICAL DATA SHEET / MAITENANCE MANUAL 1. General data. 1.1. Supply and exhaust ventilation unit with heat recovery (hereafter referred to as recuperator) is an electric device manufactured as a decentralized ventilation monoblock, which does not require connecting ducts and is designed to create and maintain a comfortable microclimate in rooms of various functional purposes. 1.2. The recuperator circulates air between the room and the outdoor air environment (street), while being located in the outer wall of the building (in-wall installation). 1.3. The efficiency of the ventilation device is achieved due to the application of high-quality and environmentally friendly components, which allows it to be highly rationally used for household objects, as well as facilities with increased requirements for sanitary conditions: apartments, private houses, cottages, offices, rooms for various purposes, educational institutions, kindergartens, workshops, stores, production premises, etc. 1.4. Recuperator countercurrent aluminium heat exchanger has high coefficient of heat exchange efficiency in both directions. The technical solution of the recuperator operation is based on the principle of heat exchange between the exhaust air flow from the room and the supply air from the street. In winter, warm and exhaust extract air transfers its heat to the supply air, heating it through the plates of the heat exchanger installed in the ventilation device. In fact, heat is recovered from the extract air, which effectively heats the fresh air supplied from the street. The heat exchanger of the device is designed in such a way that oppositely directed flows do not mix, which can significantly increase the efficiency of recuperation. In summer, the recuperator significantly reduces the temperature of the supply air from the outside, working in tandem with the indoor air conditioner. This process is directly opposite to the winter mode: the cooler air stream removed from the room cools partially the supply air. 1.5. In addition to high-efficiency heat exchange, the recuperator allows to reduce the amount of moisture in the room, removing it together with exhaust air. This helps to prevent the appearance of damp in the room, condensate on the windows, fungus and mold on the walls. 1.6. "BOUL" supply and exhaust recuperators are produced by the manufacturer in various modifications, differing mainly in productive capacity (air exchange m³/ hour), the number of operating modes and the principle of the unit control. 1.7. “BOUL” recuperators are manufactured in compliance with the requirements of TU U 27.5-39682956-002: 2021.
  • 3. 2. Main technical characteristics. 2.1. The devices are connected to the electrical network with parameters of 110-240V, 60/50 Hz. 2.2. The devices are equipped with fans with power supply 12V DC. 2.3. The productive capacity of the device (if such a parameter is provided by a particular model) is controlled via the remote control. 2.4. The main dimensions of the device: see the Figure above. Indoor view (from the room): Outdoor view (from the street): Side view:
  • 4. 3. "BOUL" recuperators model range. - The manufacturer reserves the right to change the color of the fan blades. It is black by default. Additional accessories are presented in the manufacturer's advertising catalogues. - The manufacturer has the right to expand the range of models, complementing the basic models presented above with minor characteristics. Such changes will have the prefix "+" (Pioneer 30 +, Pioneer 60 +, etc.). - The device is equipped with an automatic valve on the exhaust channel and a mechanical valve on the supply channel. Control of the valve of the supply channel is mechanical. By turning the control wheel clockwise as far as it will go, the user has the option of blocking the supply channel. - Insulation class: II. - Protection degree: IP24. - The established operation life of the system: 10 years. - Warranty period: 24 months. - Operation of the unit: at the temperatures from -30°C to + 40°C. Model name Pioneer 30 Pioneer 30+ Pioneer 60 Pioneer 60+ Evolution Diameter of working module with insulation, mm 170 170 170 170 170 Mounting hole diameter, mm 182 182 182 182 182 Recommended space area, m² (at residential ceiling height) up to 12 up to 12 up to 25-30 up to 25-30 up to 40 Number of people in the room up to 2 up to 3 up to 4 up to 4 up to 5 Air volume (m³/hour) up to 30 up to 30 up to 65 up to 65 up to 110 Number of operating modes 1: Recovery (both supply and exhaust simultaneously 1: Recovery (both supply and exhaust simultaneously 1: Recovery (both supply and exhaust simultaneously 3: Recovery, Supply, Exhaust 4: Recovery, Supply, Exhaust, Smooth speed adjustment Power consumption (W/h) 0-7 0-7 0-15 0-15 10-30 Control Manual Remote control Remote control Remote control Remote control Noise level, dB 18-20 20-22 22-24 22-24 28-36 Device weight, kg 3,2 3,2 3,5 3,5 3,5 Packing box size, mm 720*260*260 720*260*260 720*260*260 720*260*260 720*260*260
  • 5. 4. Installation. "BOUL" supply and exhaust ventilation system with heat recovery is a monoblock that is ready to use in accordance with design and layout tasks and conditions. The system is mounted into the hole of the corresponding diameter (182 mm) in the upper part of the wall, which borders the street, at a distance of at least 100-150 mm from the ceiling or wall. The inclination towards the street is implemented constructively in the device. There is no need to make a hole in the wall at an angle (!). The working module of the ventilation system is mounted into the hole on the seal (Fig.1). Fig.1. Mounting “BOUL” into the hole: The length of the working module must correspond to the thickness of the wall in which the installation is carried out (minimum 440 mm). To ensure the correct operation of the system, it is necessary that its housing, which faces the street, protrudes 1-2 cm beyond the wall till of the outlet flow canals (Exhaust air). Fig.2. Hole preparation:
  • 6. Other preparatory work includes preparation of the hole for the installation of the switch and grooves for the electrical network between the system, the switch and the place where the system is connected to the power source. CONNECTION of the recuperator to the electrical network, system control from the remote. Fig.3. Connection of recuperator to the electrical network in case of its regulation by remote control unit. Disconnect the electricity supply to the electrical network to which the ventilation system will be connected. Attention! Make sure that the power supply is actually cut off! The ventilation system is connected to a stationary electric network with 110-240V. Connection of the ventilation system to the mains is provided by an electric cable, which goes from the working module (standard configuration). If the electrical network is not connected to the mounting hole, the electrical cable from the recuperator should be connected to the mains in the junction box as shown in Fig.3. Connect the contact terminals 1 and 2 in parallel, or install the electrical connector on the cable that meets the above parameters for fast connection and disconnection of electrical devices. Electrical connectors are not included in standard configuration. If the cable of the stationary network was previously connected to the mounting hole, then the power is connected to the cable of the working module in close proximity to the recuperator housing. Сut the recuperator electric cable to the length that is convenient for electrical connection. All electrical cables used in the installation must be 0.5-0.75 mm² in section. The operation of the system is regulated by remote control unit (except BOUL «Pioneer 30» model). Remote control unit controls the operation of fans built into the housing of the ventilation system ≈110-240V
  • 7. (turns on, regulates, turns off). Recuperators BOUL are adapted to the existing electrical network in automatic mode without the use of software. This reduces significantly the noise parameters of the equipment and allows to provide the noise characteristics of the ventilation system declared in the technical data sheet. Attention! After the ventilation system is connected to the mains, it is necessary to: 1. Supply power to the system. 2. Check fan operation in different modes, using control options. 5. Operation. Maintenance. 5.1. Do not block and obscure the device with interior objects. 5.2. While exploitation, it is necessary to purge the recuperator once a year (possibly by connecting a hose to the back of the vacuum cleaner). But before it, first remove the interior part of the recuperator by pulling it towards you. 6. Transportation. Storage. 6.1. Transportation of the ventilation unit in its original packaging is allowed by any type of transport that ensures its safety from mechanical damage. 6.2. Ventilation units must be stored indoors or under a canopy and must be protected from moisture and corrosive chemicals. 7. Warranty. Warranty exploitation period, subject to the requirements of this passport for storage, transportation, installation and operation, is established for 2 years from the date of commissioning of the device, but not more than 2.5 years from the date of shipment from the manufacturer.
  • 8. WARRANTY CARD № ________________ Seller: Buyer: Equipment name: Quantity: Warranty support period: 24 months I agree with the warranty condition Sale date ___________________________ (Buyer's full name) _______ 20___ ___________________________ (Buyer's signature) Selling company __________________________________ Seller's full name ___________________________________________ Stamp 21A, Avtostradna Naberezhna, Kharkiv, 61038, Ukraine tel.: +38 (057) 780-03-28; +38 (067) 421 46 86 E-mail: trade@boul.com.ua Web: www.boul.com.ua