  1. KOBELCO Dealer name: Rao Constructions Prepared by: Suresh Vishwkarma Complain: Electric Problems Machine Model: SK220xDLC-10 ( YQ15 -B6343 ) HMR: 12869 hours Symptoms: the Display stays, on even after turning the key off Application: stone work Attachment: Bucket Trouble Shooting steps Data sheet/ Circuit ref./ Parts Photo 1 Check the machine, the Current is reaching the Display (monitor) even after the switch is off. 2 Display turns off when the relay is removed. 3 All fuses relay check, wiring check found ok 4 Suspected Alternator Regulator to not be working properly.
  2. Cause: Internal failure of regulator (faulty regular) Correction: another alternator fitment for temporary work Trouble Shooting steps Data sheet/ Circuit ref./ Parts Photo 5 Took the Alternator of Another machine and installed it in this machine (for checking purpose) 6 After fitting this Alternator, Display turns on/off as per the switch. 7. Advice the customer to Buy and Replace the Regulator at the earliest, (proud) KOBELCO CONSTRUCTION EQUIPENT INDIA PVT. LTD. KOBELCO