SlideShare a Scribd company logo
1 of 20
Download to read offline
Danso Emmanuel
Fraga Oil Gh Ltd
FUEL DISPENSING TECHNOLOGY
FUEL DISPENSORY TECHNOLOGY AT OIL MARKETING STATIONS
o Design
A modern fuel dispenser is logically divided into two main parts [1]:
 An electronic "head" containing an embedded computer to control the action of the
pump, drive the pump's displays, and communicate to an indoor sales system;
 Secondly, the mechanical section which in a ‘self-contained’ unit has an electric motor,
pumping unit, meters, pulsers and valves to physically pump and control the fuel flow.
o Vapor Recovery
Petrol contains volatile organic compounds (VOCs), which evaporate inside the fuel tank of a
vehicle and fill the air space above the liquid fuel. When a vehicle is refueled, these vapors are
forced out from the fuel tank by the incoming fuel and, unless controlled, escape into the
atmosphere through the filler neck of the fuel tank. Almost 5% is released into the environment,
which may affect the human health [2].
Fig 1 Vapor Recovery Mechanism
The ‘Stage I’ vapor recovery has been in place for a number of years at storage terminals and at
filling stations, to recover vapors that would escape into the atmosphere during the filling of
storage tanks. ‘Stage II’ controls will capture the majority of the emissions emitted from vehicle
refueling at petrol filling stations.
Fig 2 Typical Vapor Recovery System
o Reducing Dripping from Fuel Nozzle
According to the company survey, drippy fuel nozzles result in approximately half a billion liters
(132 million US gallons) of fuel falling to ground globally, every year. Not only does that
represent waste to consumers, but it is also a source of pollution – the spilled fuel evaporates into
the atmosphere, or is washed into storm sewers by rainfall [3]. Consequently, several attempts
have been made in the past to prevent pumps from dripping fuel after flow of liquid has been
stopped. So need is to give dripless experience to customer by ensuring less fuel into the
environment and more into tank.
Sunlight reacts with the air containing the volatile organic compounds and nitrous oxides
resulting in the formation of ozone directly at the source of the waste.
Fig 3 Fuel Dispenser
o Fuel Dispensing System
The design of fuel dispensing system for a gas station depends on number of factors, including
the size of the facility, its volume of business, number of grades, blends, or separate motor fuel
products sold, etc. But all retail fuel dispensing systems have three basic components:
 Storage tank
 Pipelines
 Dispenser
Fig 4 Basic Components of Fuel Dispensing System
1. Storage Tank
When the tank is filled, the rising liquid level acts as a piston, pressurizing air and vapor
in the upper portion of the tank. Conversely falling liquid level reduces the pressure as
liquid is drained during delivery. Without venting excessive pressure could strain the tank
and possibly cause leaks and pressure deficiency could strain the pumping mechanism
and even make the delivery through the system impossible, or encourage vaporization in
the delivery lines. To prevent these conditions, storage tanks have vent pipes which allow
the pressure within the tank to be maintained at a desired level. The vent line is generally
equipped with a relief valve. Fuel travels from storage tank to dispenser through
underground pipelines, which rise to the surface directly beneath the dispenser.
Fig 5 Components of Storage Tank
2. Pipelines
Pipelines must be buried far below the surface (about 18 inches) to avoid a significant
temperature differential between them and the tank. Liquid fuels tend to vaporize when
heated. This is more predominant in particular dispenser called as self-contained pump, in
which fuel in pipeline is under suction (negative pressure). Under these conditions, fuel
traveling from relatively cold storage tank through warmer pipelines may vaporize,
resulting in a condition called 'vapor lock'. This can occur in fuel dispensing systems that
have not been properly installed.
3. Dispenser
The Fuel dispenser simultaneously delivers fuel and calculates the price of the fuel
delivered. The dispenser also consists of variety of control mechanisms, which regulate
the rate of delivery, prevent over-filling and siphoning, and assures that the components
that register the volume and price are reset to zero at beginning of each delivery.
o Components of the Fuel Dispensing System
The types of retail motor-fuel dispensing systems include the following:
 Self-contained systems;
 Remote pump (or dispenser) systems; and
 Mechanical and electronic systems.
The purpose and function of each of these major components are considered
The fuel-dispensing systems performs several interrelated functions. The purpose of
some components is to maintain hydraulic continuity, to regulate the direction of flow
and fluid pressure. Others are responsible for pressurizing the fuel and moving it through
the system. Still others, of course, are involved in metering the liquid fuel, registering
accurately the quantity delivered, and computing the price of the delivery. Finally, some
components serve to control the operation of the system, switching it on and off, resetting
the volume and price indicators, regulating the delivery, and others.
1) Hydraulic Continuity
Fuel-dispensing systems are designed to measure, register, and deliver accurately the
desired quantities of fuel product. Gases such as air and fuel vapor must be prevented
from entering the dispenser’s metering device.
The most practical means of eliminating these gases is to keep the entire system-from
the storage tank to the delivery nozzle- filled with liquid at all times, even when the
system is temporarily idle. The most practical design incorporates a simple automatic
valve, called a check valve. In a fuel-dispensing system, a check valve permits liquid
fuel to flow toward the delivery nozzle, but never back toward the storage tank. There
are other automatic valves that operate in a much similar way, functioning to regulate
the direction of flow or fluid pressure of the product as it makes its way toward the
meter and discharge hose. A similar valve, located at the opposite end of the system,
prevents fuel from draining from the discharge hose, assuring delivery of the full
metered amount of fuel.
Fig 6: Automatic Check Valve
2) Pressurizing and Moving the Fuel
In retail fuel-dispensing systems, a motor-driven pump furnishes the hydraulic
pressure that moves fuel from the storage tank to the dispenser, through the metering
device, and to the discharge hose and nozzle.
Two basic types of systems are in common use – Self-contained and remote pump
systems. Most of the systems in the contemporary will be remote pump systems.
These lend themselves to larger multiple dispenser installations.
o Self-contained Systems
In self-contained systems, the pumping unit is located inside the dispenser. Its
major components are:
 A pump
 An electric motor
 An air eliminator
 Flow regulating valves
Several manufacturers produce a self-contained unit, which includes the pump, air
eliminator, valves, and flow passages connecting them, all enclosed in a single
casing, as in fig 7. The electric motor is separate, and drives the pump by means of
a belt and pulleys. Typical module is as shown in fig 8. When the dispenser’s on-
off switch is placed in the “on” position, the electric motor is activated, and begins
to turn the rotary-vane pump (other pump types may be used). As the pump turns
(say clockwise), it propels fuel forward from its outlet. This displacement of the
liquid creates a partial vacuum at the pump inlet.
As long as the discharge nozzle remains closed, this vacuum is relieved by fuel
circulating continuously through the unit. But when the nozzle is opened, suction
pressure is transferred instantaneously from the pump inlet all the way back
through the pipeline to the storage tank. There, atmospheric pressure bearing on
the surface of fuel forces it to flow through the inlet pipe and check valve into the
pipeline, and toward the dispenser. The strainer/filter removes any solid
contaminants, and is drawn into the pump inlet.
Small quantities of trapped air and fuel vapor must be removed from the fuel
before it passes to the meter. So, as it flows from the pump outlet, the fuel, now
under pressure (typically 18-25 psi) enters the air separator chamber. The shape of
this chamber forces the rapidly flowing fuel to swirl, with the result that the air and
vapor, along with a small amount of liquid fuel, are forced through an orifice into
the atmospheric chamber. Here the fuel comes to rest at atmospheric pressure. This
allows the air and vapor to rise to the portion of the chamber, where they leave the
dispenser through a vent tube. The level of the liquid that remains in the bottom of
the chamber rises until it raises the float, thereby opening a valve that allows it to
leave the chamber and be drawn along a passageway back to the pump inlet.
At the same time, the main body of fuel, free of air and vapor, passes from the
separating chamber to the automatic control valve. This valve, similar to the earlier
one, permits fuel to flow only in the direction of the meter, never back toward the
pump. It also regulates the pressure of the fuel as it leaves the pumping unit and
enters the meter, buy closing when the pressure on both sides has equalized (when
the dispenser has been turned on but the nozzle remains closed, for example)
preventing excess pressure from building I the meter and hose.
The control valve also has a built-in relief valve, which normally operates only
when the dispenser is shut off. It relieves excess pressure caused by expansion of
fuel on the discharge side of the valve by allowing a small amount to pass back
through an orifice in the center of the control valve into the air separator chamber,
where pressure can be relieved into the atmospheric chamber if necessary. The
relief valve is very important, especially in warm-weather climates, because fuel
expands when heated, and this expansion could raise pressure sufficiently to cause
seals to fail, resulting in fuel leaks, or even burst the discharge hose if not relieved.
When the pump is operating (dispenser switch is in the “on” position) but the
nozzle remains closed, the control valve will also close, as soon as pressure is
equalized. The resulting increase in pressure in the separator chamber will open the
bypass valve, permitting fuel to flow back to the pump inlet, thus relieving suction
pressure and preventing additional fuel from being drawn from the storage tank.
Fig7: Self-contained pumping unit and motor
Fig 8: Cutaway of typical Self-contained Pumping unit
o Remote Pump (or Remote Dispenser) Systems
In this type of system, fuel is pressurized and propelled toward the dispenser by a
pumping unit located at or in the storage tank. The basic components of the
pumping systems are:
 A Motor and Pump assembly and discharge head,
 An Emergency Shut-off valve, located in each dispenser, and
 A Control Valve, also located at each dispenser
Most remote systems employ a submerged pump. Thus, the pump and motor
assembly are completely submerged in the storage tank. As seen in the fig. 9, the
pump – usually a multi-stage vertical turbine – is at the very bottom of the
assembly. The intake of the submerged pump is located approximately four inches
from the bottom of the storage tank to reduce the possibility of pumping water or
sediment into the fuel system.
Fig 9: Submerged Pump and Discharge Head
Fuel is drawn into it through a metal strainer and flows from the turbine around the
outside of the motor casing and through a section of the pipe to the discharge manifold
(head), which usually sits on top of the tank. The system check valve and the air
eliminator are located inside the discharge head (manifold). The air eliminator functions
in much the same way as its counterpart in a self-contained unit: air and vapor, along
with a small quantity of fuel, are separated from the main body of fuel and drawn through
an orifice. But in this type of system, the gases and fuel drain directly back into the
storage tank; the tank itself functions as the atmospheric chamber.
In remote systems, several dispensers are often served by the same pump. When the on-
off switch at any of these dispensers is placed in the on position, the pumping unit is
activated, and all pipelines connected to the pump are pressurized (to 24-28 psi, pounds
per square inch, for a typical unit). To prevent the discharge nozzles of all the dispensers
from being pressurized, each dispenser is equipped with its own control valve.
The control valve in a remote system is not automatic: it is actuated by the dispenser's on-
off switch, or is controlled by the electronic computer system. A removable filter/strainer
at the inlet to the valve (or at the fuel inlet to the dispenser) traps solid contaminants in
the fuel flow before they enter the valve. When the piston is retracted, the valve is open
and product flows through it toward the meter; when the piston is seated, product cannot
pass through the valve.
In older systems, the control valve may be operated mechanically, by means of a linkage
between the valve and the dispenser on-off switch. Today, however, a more sophisticated
electrical operator, including a solenoid and pilot valve, has been incorporated in most
designs, as depicted in fig 10. In some systems both the main valve and the pilot valve
are incorporated into the same valve body. The device operates the valve by regulating
the fluid pressure in the cylinder behind the piston or diaphragm (the area marked “B” in
the drawing). When the dispenser is not being used (that is, the dispenser switch is in the
“off” position), the solenoid is not energized and the pilot valve rests in such a position as
to connect fluid lines (1) and (2). This maintains equal pressure on all sides of the valve
piston, allowing the spring to keep the valve tightly closed.
When the dispenser switch is turned “on” or when the electronic computer sends power
to the valve, the solenoid is energized, opening the pilot valve. This has the effect of
opening a passageway between lines (2) and (3), and simultaneously closing off line (1).
As long as the discharge nozzle remains closed, pressure remains the same in regions (A),
(B), and (C), and the control valve remains closed.
However, when the nozzle is opened, pressure at the outlet (C) falls, bleeding pressure
from the space behind the cylinder (B). Pressure is now higher at (A) than at (B), and
pressure on the head of the valve piston pushes it off its seat. When the dispenser is shut
off, the solenoid is once again de-energized, closing the pilot valve and thereby shutting
off the connection between (2) and (3) and opening the connection between (1) and (2).
When pressure is once again equal at (A), (B), and (C), the spring (or diaphragm) forces
the piston onto its seat, closing the valve.
Fig. 10 Remote-Dispenser Control Valve
The control valve prevents a remote dispenser from delivering product unless it has been
switched on, and thus prevents accidental discharge under normal conditions.
However, if a remote dispenser were to be struck with sufficient force, as might happen if
a moving vehicle collided with it, even at relatively slow speed, piping in the dispenser
could quite easily be ruptured. Since the fuel entering the dispenser is pressurized, this
situation could cause fuel to flow uncontrollably from the ruptured pipe, creating an
extreme safety hazard. To prevent this, every remote dispenser is equipped with an
automatic emergency shut-off valve, also called an impact valve or shear valve because of
its function, or a fire valve.
Fig. 11 Remote System Emergency Shut-Off (Impact or Fire) Valve
This valve is located at the bottom of the dispenser, connected to the pipeline at the point
where it enters the unit. The operation of this valve is very simple. In the event of
damaging impact, the top portion of the valve shears away, isolating the damaged
dispenser, and a spring valve automatically closes off the pipeline, preventing any further
flow of fuel from that source. If it has not been too severely damaged by the collision, the
control valve in the dispenser should then respond to the sudden drop in system pressure
and close automatically, keeping fuel loss from the dispenser also to a minimum.
Self-contained systems do not require an emergency shut-off valve because fuel is
pressurized inside the dispenser. So, a damaging collision will not result in uncontrolled
flow from the storage tank pipeline, since suction pressure will cease immediately when a
severe rupture occurs.
o Blended Dispensers
The components that pressurize and move product in a blended-product system are
essentially the same as those described above. However, the control valves in a blended-
product system serve an additional function: they must be capable of controlling the
volume flow rate of product, so that the blend will contain the correct proportions of
component products. Such devices are commonly called metering or proportioning
valves, and are somewhat more complex in operation than the basic on/off control valve
described above.
With blenders a retail outlet can provide three or more products to the consumer from
only two underground storage tanks. Thus, the environmental hazard is reduced by
having fewer underground tanks. When taking a sample for fuel quality (octane), special
notice needs to be given to the flushing recommendations made in EPO 22. (European
Patent Office)
o Multi-Product Dispensers
Prior discussion on pressurizing and moving fuel has concentrated on single and dual
product dispensers. Many, if not most, dispensers used in fuel outlets today are of the
multi-product design. Here three or more fuel products are available from a single
dispenser. Usually only one product at a time is available for delivery from each side of
the dispenser. Like the blended-product dispenser only one computer is provided on each
face of the multi-product dispenser.
The multi-product dispenser may have a hose and nozzle assembly for each product, or
there may be only one hose per dispenser side (face). In the case of the single hose multi-
product dispenser the three (or more) product discharge lines are manifolded into one
casting at or near the hose outlet fitting. Special notice should be made of the
requirements in EPO 21 for flushing the line before taking samples for fuel quality
(octane) testing.
o Metering and Indicating Fuel Delivery, and Computing Price
Two major components are involved in metering and indicating the quantity of fuel
delivered and computing the price of the delivery. In both self-contained and remote
pump (or dispenser) systems, pressurized fuel flows from the pumping unit (self-
contained systems) or control valve (remote systems) through a meter, which measures
the fuel as it is being delivered.
In the case of mechanical, analog computing systems the meter is connected directly to,
and drives, the computer through by mechanical linkage.
In the case of electronic digital computers the computer receives its information in form
of an electrical signal (pulse) from the pulsing mechanism (pulser) which is mechanically
driven by the meter. The computer indicates the amount of product delivered, the price
per gallon, and may perform other functions as well. The meter is typically a mechanical
device, but the computer may be mechanical, electronic, or both.
 The Meter
Metering devices in most gasoline and diesel retail fuel-dispensing systems are positive-
displacement meters, so called after the basic principle of their operation. In a positive
displacement meter finite quantities of fuel are separated into compartments of known
volume. These compartments may be cylinders within a piston meter, segments between
two vanes in a vane type meter, or the space between rotors in other meters. The most
popular type meter in retail fuel-dispensing systems is the piston meter.
A piston moving through a cylinder filled with liquid will displace a quantity of liquid
ahead of it. The amount of this displacement is determined by the bore of the cylinder
(it’s inside diameter) and the stroke of the piston (the maximum distance that it travels in
one direction). The positive displacement method of metering is employed in fuel
dispensers because it is capable of highly accurate measurement.
References
[1] Fuel Dispenser, Wikipedia
[2] Fuel Dispensing and Vapor Recovery Valves, ASCO, X020GB-2009/R0
[3] NIKHIL ASHOK TILAKPURE, Non Dripping Nozzle for Fuel Dispenser Pump,
Birla Institute of Technology and Science, Pilani Hyderabad Campus, Nov 2014

More Related Content

What's hot

What's hot (20)

Stratified-charge-engine-ppt
Stratified-charge-engine-pptStratified-charge-engine-ppt
Stratified-charge-engine-ppt
 
7 power brakes
7 power brakes7 power brakes
7 power brakes
 
vacuum braking system
vacuum braking systemvacuum braking system
vacuum braking system
 
Fuel injector
Fuel injectorFuel injector
Fuel injector
 
types of fuel injection system and nozzles
types of fuel injection system and nozzlestypes of fuel injection system and nozzles
types of fuel injection system and nozzles
 
EFI system
EFI systemEFI system
EFI system
 
Chap70
Chap70Chap70
Chap70
 
ppt of fuel injection system
ppt of fuel injection systemppt of fuel injection system
ppt of fuel injection system
 
Lesson - Air Brake System.ppt
Lesson - Air Brake System.pptLesson - Air Brake System.ppt
Lesson - Air Brake System.ppt
 
Ch 33 oil separators
Ch 33   oil separatorsCh 33   oil separators
Ch 33 oil separators
 
EFI system
EFI systemEFI system
EFI system
 
Common rail diesel fuel systems
Common rail diesel fuel systemsCommon rail diesel fuel systems
Common rail diesel fuel systems
 
Fuel pump dispensing machine
Fuel pump dispensing machineFuel pump dispensing machine
Fuel pump dispensing machine
 
TYPES OF CARBURETORS
TYPES OF CARBURETORSTYPES OF CARBURETORS
TYPES OF CARBURETORS
 
Air Brake System .pdf
Air Brake System .pdfAir Brake System .pdf
Air Brake System .pdf
 
Types of compressor and application in oil and gas industry
Types of compressor and application in oil and gas industryTypes of compressor and application in oil and gas industry
Types of compressor and application in oil and gas industry
 
Ignition systems
Ignition systemsIgnition systems
Ignition systems
 
Air breaking system in indian railway
Air breaking system in indian railwayAir breaking system in indian railway
Air breaking system in indian railway
 
Carburetors types
Carburetors typesCarburetors types
Carburetors types
 
MPFI & CRDI
MPFI & CRDIMPFI & CRDI
MPFI & CRDI
 

Similar to Fuel Dispensing Technology

CIE injection ver 3 spring 2100000.ppsx
CIE injection  ver 3 spring 2100000.ppsxCIE injection  ver 3 spring 2100000.ppsx
CIE injection ver 3 spring 2100000.ppsx
BfhfHdhg
 
Archive for the ‘refrigerator commissioning’ tag
Archive for the ‘refrigerator commissioning’ tagArchive for the ‘refrigerator commissioning’ tag
Archive for the ‘refrigerator commissioning’ tag
Muhammad Awais
 

Similar to Fuel Dispensing Technology (20)

Fundamental of hydraulics
Fundamental of hydraulicsFundamental of hydraulics
Fundamental of hydraulics
 
Basic Carburetor Design
Basic Carburetor DesignBasic Carburetor Design
Basic Carburetor Design
 
SIAUT_Fuel_Injection_Systems-Gasoline.pdf
SIAUT_Fuel_Injection_Systems-Gasoline.pdfSIAUT_Fuel_Injection_Systems-Gasoline.pdf
SIAUT_Fuel_Injection_Systems-Gasoline.pdf
 
CIE injection ver 3 spring 2100000.ppsx
CIE injection  ver 3 spring 2100000.ppsxCIE injection  ver 3 spring 2100000.ppsx
CIE injection ver 3 spring 2100000.ppsx
 
Hydraulics-fundamentals of hydraulics.ppt
Hydraulics-fundamentals of hydraulics.pptHydraulics-fundamentals of hydraulics.ppt
Hydraulics-fundamentals of hydraulics.ppt
 
Airframe 1 (done)
Airframe 1 (done)Airframe 1 (done)
Airframe 1 (done)
 
40266484-Fundamentals-of-Hydraulics.pdf
40266484-Fundamentals-of-Hydraulics.pdf40266484-Fundamentals-of-Hydraulics.pdf
40266484-Fundamentals-of-Hydraulics.pdf
 
Principles of carburetion
Principles of carburetionPrinciples of carburetion
Principles of carburetion
 
Theory 3.pptx
Theory 3.pptxTheory 3.pptx
Theory 3.pptx
 
UNIT-II-ENGINE AUXILIARY SYSTEMS.pptx
UNIT-II-ENGINE AUXILIARY SYSTEMS.pptxUNIT-II-ENGINE AUXILIARY SYSTEMS.pptx
UNIT-II-ENGINE AUXILIARY SYSTEMS.pptx
 
UNIT-II-ENGINE AUXILIARY SYSTEMS.pptx
UNIT-II-ENGINE AUXILIARY SYSTEMS.pptxUNIT-II-ENGINE AUXILIARY SYSTEMS.pptx
UNIT-II-ENGINE AUXILIARY SYSTEMS.pptx
 
THIS PPT ON ELECTRONIC FUEL INJECTION SYSTEM
THIS PPT ON ELECTRONIC FUEL INJECTION SYSTEMTHIS PPT ON ELECTRONIC FUEL INJECTION SYSTEM
THIS PPT ON ELECTRONIC FUEL INJECTION SYSTEM
 
Unit 2.pdf
Unit 2.pdfUnit 2.pdf
Unit 2.pdf
 
Engine Systems.pptx
Engine Systems.pptxEngine Systems.pptx
Engine Systems.pptx
 
Chapter 9 Mechanical Injection Systems.pdf
Chapter 9 Mechanical Injection Systems.pdfChapter 9 Mechanical Injection Systems.pdf
Chapter 9 Mechanical Injection Systems.pdf
 
Archive for the ‘refrigerator commissioning’ tag
Archive for the ‘refrigerator commissioning’ tagArchive for the ‘refrigerator commissioning’ tag
Archive for the ‘refrigerator commissioning’ tag
 
Power Plant
Power PlantPower Plant
Power Plant
 
Automotive fuel System-- Part II.pptx
Automotive fuel System-- Part II.pptxAutomotive fuel System-- Part II.pptx
Automotive fuel System-- Part II.pptx
 
Aircraft Fuel System
Aircraft Fuel System Aircraft Fuel System
Aircraft Fuel System
 
Automotive System presentation
Automotive System presentationAutomotive System presentation
Automotive System presentation
 

Recently uploaded

Recently uploaded (20)

GenCyber Cyber Security Day Presentation
GenCyber Cyber Security Day PresentationGenCyber Cyber Security Day Presentation
GenCyber Cyber Security Day Presentation
 
AWS Community Day CPH - Three problems of Terraform
AWS Community Day CPH - Three problems of TerraformAWS Community Day CPH - Three problems of Terraform
AWS Community Day CPH - Three problems of Terraform
 
HTML Injection Attacks: Impact and Mitigation Strategies
HTML Injection Attacks: Impact and Mitigation StrategiesHTML Injection Attacks: Impact and Mitigation Strategies
HTML Injection Attacks: Impact and Mitigation Strategies
 
Tata AIG General Insurance Company - Insurer Innovation Award 2024
Tata AIG General Insurance Company - Insurer Innovation Award 2024Tata AIG General Insurance Company - Insurer Innovation Award 2024
Tata AIG General Insurance Company - Insurer Innovation Award 2024
 
presentation ICT roal in 21st century education
presentation ICT roal in 21st century educationpresentation ICT roal in 21st century education
presentation ICT roal in 21st century education
 
Boost PC performance: How more available memory can improve productivity
Boost PC performance: How more available memory can improve productivityBoost PC performance: How more available memory can improve productivity
Boost PC performance: How more available memory can improve productivity
 
Finology Group – Insurtech Innovation Award 2024
Finology Group – Insurtech Innovation Award 2024Finology Group – Insurtech Innovation Award 2024
Finology Group – Insurtech Innovation Award 2024
 
The 7 Things I Know About Cyber Security After 25 Years | April 2024
The 7 Things I Know About Cyber Security After 25 Years | April 2024The 7 Things I Know About Cyber Security After 25 Years | April 2024
The 7 Things I Know About Cyber Security After 25 Years | April 2024
 
Understanding Discord NSFW Servers A Guide for Responsible Users.pdf
Understanding Discord NSFW Servers A Guide for Responsible Users.pdfUnderstanding Discord NSFW Servers A Guide for Responsible Users.pdf
Understanding Discord NSFW Servers A Guide for Responsible Users.pdf
 
A Year of the Servo Reboot: Where Are We Now?
A Year of the Servo Reboot: Where Are We Now?A Year of the Servo Reboot: Where Are We Now?
A Year of the Servo Reboot: Where Are We Now?
 
Bajaj Allianz Life Insurance Company - Insurer Innovation Award 2024
Bajaj Allianz Life Insurance Company - Insurer Innovation Award 2024Bajaj Allianz Life Insurance Company - Insurer Innovation Award 2024
Bajaj Allianz Life Insurance Company - Insurer Innovation Award 2024
 
Real Time Object Detection Using Open CV
Real Time Object Detection Using Open CVReal Time Object Detection Using Open CV
Real Time Object Detection Using Open CV
 
TrustArc Webinar - Unlock the Power of AI-Driven Data Discovery
TrustArc Webinar - Unlock the Power of AI-Driven Data DiscoveryTrustArc Webinar - Unlock the Power of AI-Driven Data Discovery
TrustArc Webinar - Unlock the Power of AI-Driven Data Discovery
 
A Domino Admins Adventures (Engage 2024)
A Domino Admins Adventures (Engage 2024)A Domino Admins Adventures (Engage 2024)
A Domino Admins Adventures (Engage 2024)
 
Workshop - Best of Both Worlds_ Combine KG and Vector search for enhanced R...
Workshop - Best of Both Worlds_ Combine  KG and Vector search for  enhanced R...Workshop - Best of Both Worlds_ Combine  KG and Vector search for  enhanced R...
Workshop - Best of Both Worlds_ Combine KG and Vector search for enhanced R...
 
Advantages of Hiring UIUX Design Service Providers for Your Business
Advantages of Hiring UIUX Design Service Providers for Your BusinessAdvantages of Hiring UIUX Design Service Providers for Your Business
Advantages of Hiring UIUX Design Service Providers for Your Business
 
Mastering MySQL Database Architecture: Deep Dive into MySQL Shell and MySQL R...
Mastering MySQL Database Architecture: Deep Dive into MySQL Shell and MySQL R...Mastering MySQL Database Architecture: Deep Dive into MySQL Shell and MySQL R...
Mastering MySQL Database Architecture: Deep Dive into MySQL Shell and MySQL R...
 
Automating Google Workspace (GWS) & more with Apps Script
Automating Google Workspace (GWS) & more with Apps ScriptAutomating Google Workspace (GWS) & more with Apps Script
Automating Google Workspace (GWS) & more with Apps Script
 
Powerful Google developer tools for immediate impact! (2023-24 C)
Powerful Google developer tools for immediate impact! (2023-24 C)Powerful Google developer tools for immediate impact! (2023-24 C)
Powerful Google developer tools for immediate impact! (2023-24 C)
 
2024: Domino Containers - The Next Step. News from the Domino Container commu...
2024: Domino Containers - The Next Step. News from the Domino Container commu...2024: Domino Containers - The Next Step. News from the Domino Container commu...
2024: Domino Containers - The Next Step. News from the Domino Container commu...
 

Fuel Dispensing Technology

  • 1. Danso Emmanuel Fraga Oil Gh Ltd FUEL DISPENSING TECHNOLOGY
  • 2. FUEL DISPENSORY TECHNOLOGY AT OIL MARKETING STATIONS o Design A modern fuel dispenser is logically divided into two main parts [1]:  An electronic "head" containing an embedded computer to control the action of the pump, drive the pump's displays, and communicate to an indoor sales system;  Secondly, the mechanical section which in a ‘self-contained’ unit has an electric motor, pumping unit, meters, pulsers and valves to physically pump and control the fuel flow. o Vapor Recovery Petrol contains volatile organic compounds (VOCs), which evaporate inside the fuel tank of a vehicle and fill the air space above the liquid fuel. When a vehicle is refueled, these vapors are forced out from the fuel tank by the incoming fuel and, unless controlled, escape into the atmosphere through the filler neck of the fuel tank. Almost 5% is released into the environment, which may affect the human health [2].
  • 3. Fig 1 Vapor Recovery Mechanism The ‘Stage I’ vapor recovery has been in place for a number of years at storage terminals and at filling stations, to recover vapors that would escape into the atmosphere during the filling of storage tanks. ‘Stage II’ controls will capture the majority of the emissions emitted from vehicle refueling at petrol filling stations.
  • 4. Fig 2 Typical Vapor Recovery System o Reducing Dripping from Fuel Nozzle According to the company survey, drippy fuel nozzles result in approximately half a billion liters (132 million US gallons) of fuel falling to ground globally, every year. Not only does that
  • 5. represent waste to consumers, but it is also a source of pollution – the spilled fuel evaporates into the atmosphere, or is washed into storm sewers by rainfall [3]. Consequently, several attempts have been made in the past to prevent pumps from dripping fuel after flow of liquid has been stopped. So need is to give dripless experience to customer by ensuring less fuel into the environment and more into tank. Sunlight reacts with the air containing the volatile organic compounds and nitrous oxides resulting in the formation of ozone directly at the source of the waste. Fig 3 Fuel Dispenser
  • 6. o Fuel Dispensing System The design of fuel dispensing system for a gas station depends on number of factors, including the size of the facility, its volume of business, number of grades, blends, or separate motor fuel products sold, etc. But all retail fuel dispensing systems have three basic components:  Storage tank  Pipelines  Dispenser Fig 4 Basic Components of Fuel Dispensing System 1. Storage Tank When the tank is filled, the rising liquid level acts as a piston, pressurizing air and vapor in the upper portion of the tank. Conversely falling liquid level reduces the pressure as liquid is drained during delivery. Without venting excessive pressure could strain the tank and possibly cause leaks and pressure deficiency could strain the pumping mechanism and even make the delivery through the system impossible, or encourage vaporization in the delivery lines. To prevent these conditions, storage tanks have vent pipes which allow the pressure within the tank to be maintained at a desired level. The vent line is generally equipped with a relief valve. Fuel travels from storage tank to dispenser through underground pipelines, which rise to the surface directly beneath the dispenser.
  • 7. Fig 5 Components of Storage Tank 2. Pipelines Pipelines must be buried far below the surface (about 18 inches) to avoid a significant temperature differential between them and the tank. Liquid fuels tend to vaporize when heated. This is more predominant in particular dispenser called as self-contained pump, in which fuel in pipeline is under suction (negative pressure). Under these conditions, fuel traveling from relatively cold storage tank through warmer pipelines may vaporize, resulting in a condition called 'vapor lock'. This can occur in fuel dispensing systems that have not been properly installed. 3. Dispenser The Fuel dispenser simultaneously delivers fuel and calculates the price of the fuel delivered. The dispenser also consists of variety of control mechanisms, which regulate
  • 8. the rate of delivery, prevent over-filling and siphoning, and assures that the components that register the volume and price are reset to zero at beginning of each delivery. o Components of the Fuel Dispensing System The types of retail motor-fuel dispensing systems include the following:  Self-contained systems;  Remote pump (or dispenser) systems; and  Mechanical and electronic systems. The purpose and function of each of these major components are considered The fuel-dispensing systems performs several interrelated functions. The purpose of some components is to maintain hydraulic continuity, to regulate the direction of flow and fluid pressure. Others are responsible for pressurizing the fuel and moving it through the system. Still others, of course, are involved in metering the liquid fuel, registering accurately the quantity delivered, and computing the price of the delivery. Finally, some components serve to control the operation of the system, switching it on and off, resetting the volume and price indicators, regulating the delivery, and others. 1) Hydraulic Continuity Fuel-dispensing systems are designed to measure, register, and deliver accurately the desired quantities of fuel product. Gases such as air and fuel vapor must be prevented from entering the dispenser’s metering device. The most practical means of eliminating these gases is to keep the entire system-from the storage tank to the delivery nozzle- filled with liquid at all times, even when the system is temporarily idle. The most practical design incorporates a simple automatic valve, called a check valve. In a fuel-dispensing system, a check valve permits liquid fuel to flow toward the delivery nozzle, but never back toward the storage tank. There are other automatic valves that operate in a much similar way, functioning to regulate the direction of flow or fluid pressure of the product as it makes its way toward the meter and discharge hose. A similar valve, located at the opposite end of the system, prevents fuel from draining from the discharge hose, assuring delivery of the full metered amount of fuel.
  • 9. Fig 6: Automatic Check Valve
  • 10. 2) Pressurizing and Moving the Fuel In retail fuel-dispensing systems, a motor-driven pump furnishes the hydraulic pressure that moves fuel from the storage tank to the dispenser, through the metering device, and to the discharge hose and nozzle. Two basic types of systems are in common use – Self-contained and remote pump systems. Most of the systems in the contemporary will be remote pump systems. These lend themselves to larger multiple dispenser installations. o Self-contained Systems In self-contained systems, the pumping unit is located inside the dispenser. Its major components are:  A pump  An electric motor  An air eliminator  Flow regulating valves Several manufacturers produce a self-contained unit, which includes the pump, air eliminator, valves, and flow passages connecting them, all enclosed in a single casing, as in fig 7. The electric motor is separate, and drives the pump by means of a belt and pulleys. Typical module is as shown in fig 8. When the dispenser’s on- off switch is placed in the “on” position, the electric motor is activated, and begins to turn the rotary-vane pump (other pump types may be used). As the pump turns (say clockwise), it propels fuel forward from its outlet. This displacement of the liquid creates a partial vacuum at the pump inlet. As long as the discharge nozzle remains closed, this vacuum is relieved by fuel circulating continuously through the unit. But when the nozzle is opened, suction pressure is transferred instantaneously from the pump inlet all the way back through the pipeline to the storage tank. There, atmospheric pressure bearing on the surface of fuel forces it to flow through the inlet pipe and check valve into the
  • 11. pipeline, and toward the dispenser. The strainer/filter removes any solid contaminants, and is drawn into the pump inlet. Small quantities of trapped air and fuel vapor must be removed from the fuel before it passes to the meter. So, as it flows from the pump outlet, the fuel, now under pressure (typically 18-25 psi) enters the air separator chamber. The shape of this chamber forces the rapidly flowing fuel to swirl, with the result that the air and vapor, along with a small amount of liquid fuel, are forced through an orifice into the atmospheric chamber. Here the fuel comes to rest at atmospheric pressure. This allows the air and vapor to rise to the portion of the chamber, where they leave the dispenser through a vent tube. The level of the liquid that remains in the bottom of the chamber rises until it raises the float, thereby opening a valve that allows it to leave the chamber and be drawn along a passageway back to the pump inlet. At the same time, the main body of fuel, free of air and vapor, passes from the separating chamber to the automatic control valve. This valve, similar to the earlier one, permits fuel to flow only in the direction of the meter, never back toward the pump. It also regulates the pressure of the fuel as it leaves the pumping unit and enters the meter, buy closing when the pressure on both sides has equalized (when the dispenser has been turned on but the nozzle remains closed, for example) preventing excess pressure from building I the meter and hose. The control valve also has a built-in relief valve, which normally operates only when the dispenser is shut off. It relieves excess pressure caused by expansion of fuel on the discharge side of the valve by allowing a small amount to pass back through an orifice in the center of the control valve into the air separator chamber, where pressure can be relieved into the atmospheric chamber if necessary. The relief valve is very important, especially in warm-weather climates, because fuel expands when heated, and this expansion could raise pressure sufficiently to cause seals to fail, resulting in fuel leaks, or even burst the discharge hose if not relieved. When the pump is operating (dispenser switch is in the “on” position) but the nozzle remains closed, the control valve will also close, as soon as pressure is
  • 12. equalized. The resulting increase in pressure in the separator chamber will open the bypass valve, permitting fuel to flow back to the pump inlet, thus relieving suction pressure and preventing additional fuel from being drawn from the storage tank. Fig7: Self-contained pumping unit and motor
  • 13. Fig 8: Cutaway of typical Self-contained Pumping unit o Remote Pump (or Remote Dispenser) Systems In this type of system, fuel is pressurized and propelled toward the dispenser by a pumping unit located at or in the storage tank. The basic components of the pumping systems are:  A Motor and Pump assembly and discharge head,  An Emergency Shut-off valve, located in each dispenser, and
  • 14.  A Control Valve, also located at each dispenser Most remote systems employ a submerged pump. Thus, the pump and motor assembly are completely submerged in the storage tank. As seen in the fig. 9, the pump – usually a multi-stage vertical turbine – is at the very bottom of the assembly. The intake of the submerged pump is located approximately four inches from the bottom of the storage tank to reduce the possibility of pumping water or sediment into the fuel system. Fig 9: Submerged Pump and Discharge Head Fuel is drawn into it through a metal strainer and flows from the turbine around the outside of the motor casing and through a section of the pipe to the discharge manifold (head), which usually sits on top of the tank. The system check valve and the air eliminator are located inside the discharge head (manifold). The air eliminator functions in much the same way as its counterpart in a self-contained unit: air and vapor, along
  • 15. with a small quantity of fuel, are separated from the main body of fuel and drawn through an orifice. But in this type of system, the gases and fuel drain directly back into the storage tank; the tank itself functions as the atmospheric chamber. In remote systems, several dispensers are often served by the same pump. When the on- off switch at any of these dispensers is placed in the on position, the pumping unit is activated, and all pipelines connected to the pump are pressurized (to 24-28 psi, pounds per square inch, for a typical unit). To prevent the discharge nozzles of all the dispensers from being pressurized, each dispenser is equipped with its own control valve. The control valve in a remote system is not automatic: it is actuated by the dispenser's on- off switch, or is controlled by the electronic computer system. A removable filter/strainer at the inlet to the valve (or at the fuel inlet to the dispenser) traps solid contaminants in the fuel flow before they enter the valve. When the piston is retracted, the valve is open and product flows through it toward the meter; when the piston is seated, product cannot pass through the valve. In older systems, the control valve may be operated mechanically, by means of a linkage between the valve and the dispenser on-off switch. Today, however, a more sophisticated electrical operator, including a solenoid and pilot valve, has been incorporated in most designs, as depicted in fig 10. In some systems both the main valve and the pilot valve are incorporated into the same valve body. The device operates the valve by regulating the fluid pressure in the cylinder behind the piston or diaphragm (the area marked “B” in the drawing). When the dispenser is not being used (that is, the dispenser switch is in the “off” position), the solenoid is not energized and the pilot valve rests in such a position as to connect fluid lines (1) and (2). This maintains equal pressure on all sides of the valve piston, allowing the spring to keep the valve tightly closed. When the dispenser switch is turned “on” or when the electronic computer sends power to the valve, the solenoid is energized, opening the pilot valve. This has the effect of opening a passageway between lines (2) and (3), and simultaneously closing off line (1). As long as the discharge nozzle remains closed, pressure remains the same in regions (A), (B), and (C), and the control valve remains closed.
  • 16. However, when the nozzle is opened, pressure at the outlet (C) falls, bleeding pressure from the space behind the cylinder (B). Pressure is now higher at (A) than at (B), and pressure on the head of the valve piston pushes it off its seat. When the dispenser is shut off, the solenoid is once again de-energized, closing the pilot valve and thereby shutting off the connection between (2) and (3) and opening the connection between (1) and (2). When pressure is once again equal at (A), (B), and (C), the spring (or diaphragm) forces the piston onto its seat, closing the valve. Fig. 10 Remote-Dispenser Control Valve The control valve prevents a remote dispenser from delivering product unless it has been switched on, and thus prevents accidental discharge under normal conditions.
  • 17. However, if a remote dispenser were to be struck with sufficient force, as might happen if a moving vehicle collided with it, even at relatively slow speed, piping in the dispenser could quite easily be ruptured. Since the fuel entering the dispenser is pressurized, this situation could cause fuel to flow uncontrollably from the ruptured pipe, creating an extreme safety hazard. To prevent this, every remote dispenser is equipped with an automatic emergency shut-off valve, also called an impact valve or shear valve because of its function, or a fire valve. Fig. 11 Remote System Emergency Shut-Off (Impact or Fire) Valve This valve is located at the bottom of the dispenser, connected to the pipeline at the point where it enters the unit. The operation of this valve is very simple. In the event of damaging impact, the top portion of the valve shears away, isolating the damaged dispenser, and a spring valve automatically closes off the pipeline, preventing any further flow of fuel from that source. If it has not been too severely damaged by the collision, the control valve in the dispenser should then respond to the sudden drop in system pressure and close automatically, keeping fuel loss from the dispenser also to a minimum. Self-contained systems do not require an emergency shut-off valve because fuel is pressurized inside the dispenser. So, a damaging collision will not result in uncontrolled
  • 18. flow from the storage tank pipeline, since suction pressure will cease immediately when a severe rupture occurs. o Blended Dispensers The components that pressurize and move product in a blended-product system are essentially the same as those described above. However, the control valves in a blended- product system serve an additional function: they must be capable of controlling the volume flow rate of product, so that the blend will contain the correct proportions of component products. Such devices are commonly called metering or proportioning valves, and are somewhat more complex in operation than the basic on/off control valve described above. With blenders a retail outlet can provide three or more products to the consumer from only two underground storage tanks. Thus, the environmental hazard is reduced by having fewer underground tanks. When taking a sample for fuel quality (octane), special notice needs to be given to the flushing recommendations made in EPO 22. (European Patent Office) o Multi-Product Dispensers Prior discussion on pressurizing and moving fuel has concentrated on single and dual product dispensers. Many, if not most, dispensers used in fuel outlets today are of the multi-product design. Here three or more fuel products are available from a single dispenser. Usually only one product at a time is available for delivery from each side of the dispenser. Like the blended-product dispenser only one computer is provided on each face of the multi-product dispenser. The multi-product dispenser may have a hose and nozzle assembly for each product, or there may be only one hose per dispenser side (face). In the case of the single hose multi- product dispenser the three (or more) product discharge lines are manifolded into one casting at or near the hose outlet fitting. Special notice should be made of the requirements in EPO 21 for flushing the line before taking samples for fuel quality (octane) testing. o Metering and Indicating Fuel Delivery, and Computing Price
  • 19. Two major components are involved in metering and indicating the quantity of fuel delivered and computing the price of the delivery. In both self-contained and remote pump (or dispenser) systems, pressurized fuel flows from the pumping unit (self- contained systems) or control valve (remote systems) through a meter, which measures the fuel as it is being delivered. In the case of mechanical, analog computing systems the meter is connected directly to, and drives, the computer through by mechanical linkage. In the case of electronic digital computers the computer receives its information in form of an electrical signal (pulse) from the pulsing mechanism (pulser) which is mechanically driven by the meter. The computer indicates the amount of product delivered, the price per gallon, and may perform other functions as well. The meter is typically a mechanical device, but the computer may be mechanical, electronic, or both.  The Meter Metering devices in most gasoline and diesel retail fuel-dispensing systems are positive- displacement meters, so called after the basic principle of their operation. In a positive displacement meter finite quantities of fuel are separated into compartments of known volume. These compartments may be cylinders within a piston meter, segments between two vanes in a vane type meter, or the space between rotors in other meters. The most popular type meter in retail fuel-dispensing systems is the piston meter. A piston moving through a cylinder filled with liquid will displace a quantity of liquid ahead of it. The amount of this displacement is determined by the bore of the cylinder (it’s inside diameter) and the stroke of the piston (the maximum distance that it travels in one direction). The positive displacement method of metering is employed in fuel dispensers because it is capable of highly accurate measurement.
  • 20. References [1] Fuel Dispenser, Wikipedia [2] Fuel Dispensing and Vapor Recovery Valves, ASCO, X020GB-2009/R0 [3] NIKHIL ASHOK TILAKPURE, Non Dripping Nozzle for Fuel Dispenser Pump, Birla Institute of Technology and Science, Pilani Hyderabad Campus, Nov 2014