Ce diaporama a bien été signalé.
Nous utilisons votre profil LinkedIn et vos données d’activité pour vous proposer des publicités personnalisées et pertinentes. Vous pouvez changer vos préférences de publicités à tout moment.

Data Center Modernization for Fibre Channel SAN

310 vues

Publié le

While we do not naturally associate Fibre Channel SAN as a “modern” environment, there have been significant recent developments that greatly improve its performance, availability, reach, and management for storage. This is particularly true of network connectivity options, specifically the Gen 6 Fibre Channel protocol. This session will cover the Brocade family of high-performance, energy-efficient, highly scalable Fibre Channel SAN products available for connection to Fujitsu storage environments. We will also discuss advanced fabric capabilities such as distance extension and network analytics, and offer a glimpse into promising new technologies such as NVMe over Fibre Channel.
Speaker:
Kyle Roblyer
Frank Reichart

Publié dans : Technologie
  • Soyez le premier à commenter

Data Center Modernization for Fibre Channel SAN

  1. 1. 0 © Copyright 2017 FUJITSU Fujitsu Forum 2017 #FujitsuForum
  2. 2. 1 © Copyright 2017 FUJITSU Data Center Modernization for Fibre Channel SAN Kyle Roblyer Director, Global Partner Marketing Brocade Frank Reichart Sen. Dir. Product Marketing Storage Fujitsu
  3. 3. 2 © Copyright 2017 FUJITSU Modern!
  4. 4. 3 © Copyright 2017 FUJITSU Modern?
  5. 5. 4 © Copyright 2017 FUJITSU Modern!
  6. 6. 5 © Copyright 2017 FUJITSU Storage Trends: Total Market by Company Revenue Small Businesses are buying storage 44% 19% 7% <$100M $100 – 500M $500M – 1B $1 – 6B $6 – 16B >$16B of Buyers are Small Businesses 65% Plan to Increase Storage Spending 63%
  7. 7. 6 © Copyright 2017 FUJITSU Storage Trends: Network & Capacity Planning Fibre Channel Dominates And Is Growing! 55% 55% 74% NFS/SMB iSCSI Fibre Channel 52% 45% 59% 31% 29% 27% 17% 26% 15% NFS/SMB iSCSI Fibre Channel Increase Stay the same Decrease In Use Today 2 Years Forward
  8. 8. 7 © Copyright 2017 FUJITSU The DC IT architecture becomes bi-modal Flexible functional scalability SAN Network Servers All-flash storage Integrated scalability IP network Servers JBOD/int. storage IP network Servers JBOD/int. storage IP network Servers JBOD/int. storage Robust IT 3-tier or converged IT tailored core applications Fast IT hyperconverged, SW-defined IT edge applications
  9. 9. 8 © Copyright 2017 FUJITSU The right system platforms for all IT architectures Robust IT 3-tier architecture SAN Fast IT Hyperconverged architecture IP Mission critical servers Scale-out serversRack servers All-flash and hybrid, controller-based storage Software-defined, server based storage
  10. 10. 9 © Copyright 2017 FUJITSU The economics of all-flash storage 5× 3× 100× 10× 500× 10× 5× 80% More IOPS More effective data reduction Better reliability Higher density Lower response time Less power consumption Faster rebuilds Less main- tenance costs 5× Better $/IOPS ratio
  11. 11. 10 © Copyright 2017 FUJITSU ETERNUS AF: fast, dense, reliable, efficient Leads in response time (04ms under full load) Fully integrated in ETERNUS DX hybrid storage line Full Disaster Recovery with mirroring, replication and transparent failover Flexible use of deduplication and compression where it makes sense Automated Quality of Service management ETERNUS AF250 ETERNUS AF650  Up to 730 TB in 8 HU  430+ k IOPS  32 G FC  Up to 2,930 TB in 19 HU  620+ k IOPS  32 G FC
  12. 12. 11 © Copyright 2017 FUJITSU Older Networks Will Bottleneck Flash Flash storage demands maximum network speed and throughput 0 300 600 900 1200 1500 1800 Query Time 8 Gbps 16 Gbps 32 Gbps less time 71% Connectivity to 8 Gbps flash storage Emulex/Broadcom TPC-H benchmark Testing 4× Complete more database queries 71% Complete queries faster
  13. 13. 12 © Copyright 2017 FUJITSU All-Flash Storage Requires Gen 6 Fibre Channel 1 As compared to 8 GFC Emulex/Broadcom TPC-H benchmark Testing Workload Completion Time Improvement with 32 GFC1 ~4× Workload Completion Time Improvement with 16 GFC1 ~2× 0 200 400 600 800 VDI Bootstorm Data Warehouse Storage vMotion 0 50 100 150 0 1000 2000 3000 Lower is better VDI “Bootstorm” Time Data Warehouse DSS Query Time Storage vMotion Time 0 2000 4000 6000 8000 Data Warehouse Storage Migration Storage XenMotion 0 20 40 60 80 100 0 20 40 60 80 100 Data Warehouse DSS Query Time Storage Migration Storage XenMotion Time 8 GFC 16 GFC 32 GFC
  14. 14. 13 © Copyright 2017 FUJITSU Storage modernization starts with Gen 6 Fibre Channel Greater predictability and proven reliability drives non- stop operations Unmatched performance powers critical applications and flash architectures Purpose-built simplicity enables scalability without complexity Brocade Gen 6 Portfolio Brocade G610 Brocade G620 Brocade Analytics Monitoring Platform Brocade X6 Port and Extension Blades Brocade X6 Directors
  15. 15. 14 © Copyright 2017 FUJITSU Flash investments need to go hand in and with network upgrades The impact of all-flash on networks Make sure the network doesn’t become a bottleneck 26% 44% 21% Strongly agree Agree Maybe Disagree Strongly disagree Unsure 70% strongly agree or agree But while AFAs clearly improve performance within the array itself, it is important to recognise that removing a bottleneck in one location could move it somewhere else. In particular it is essential to ensure that the network can support the additional performance enabled by generation two flash storage technologies.
  16. 16. 15 © Copyright 2017 FUJITSU Redefine the Economics of Storage Networking The Brocade G610 is a low-entry-cost, no-compromise storage switch that delivers a flash-ready solution for the always-on business Low Entry Cost Low-entry-cost storage switch that redefines simplicity and flexibility Always On Rely on the network that delivers always-on business operations Flash-Ready Build a high performance infrastructure that adapts to evolving storage requirements
  17. 17. 16 © Copyright 2017 FUJITSU Newest Addition to the SAN Portfolio: Brocade G610 Switch Brocade G610 Switch 24×32 Gbps SFP+ ports Affordable, entry-level switch  Start small and grow on demand from 8 to 24 ports Simple deployment  Install in three easy steps and deploy 20 years of best practices in a single click Flash-ready performance  Power up from 16 to 32 Gbps on-demand  Built-in NVMe ready New Fabric Vision Capabilities with VM Insight  Proactively deliver continuous uptime by monitoring health and performance of VMs  Identify VM anomalies and address abnormal behaviors
  18. 18. 17 © Copyright 2017 FUJITSU Simple and Scalable Install in three easy steps Brocade EZSwitchSetup  Automatically installs from CD  Easy-to-use GUI for setting up and managing a single switch  Intuitive device management Deploy a switch faster  Minutes vs. hours  Eliminates configuration errors Start small and grow on demand From 8 to 24 ports
  19. 19. 18 © Copyright 2017 FUJITSU Advanced Fabric Management: Brocade Fabric Vision
  20. 20. 19 © Copyright 2017 FUJITSU Innovation in Fabric Management: Brocade Fabric Vision Real-Time Visibility and Actionable Insights Deploy pre-defined policies, rules, and actions Simplify Monitoring Increase instrumentation and granularity Visualize network health and performance Deploy 15 years of best practices in one click Improve OpEx savings through automated actions Reduce Costs Save $ on CapEx costs from third-party tools Validate infrastructure prior to deployment Eliminate maintenance costs Automatically detect and recover from errors Increase Availability Provide early warning of potential problems Minimize downtime with faster troubleshooting Reduce common network problems
  21. 21. 20 © Copyright 2017 FUJITSU Brocade Fabric Vision Features IO Insight Automatically detects degraded storage IO performance with integrated device latency and IOPS monitoring VM Insight Seamlessly monitors VM performance throughout a storage fabric with standards-based, end-to-end VM tagging Dashboards Customizable health and performance dashboard, with all critical information on one screen Buffer Credit Recovery Automatically recovers flow control buffer credit loss at the VC level, improving availability Fabric Performance Impact Monitoring Quickly detects and clearly alerts admins to high levels of latency, helping to identify slow drain devices Forward Error Correction Automatically detects and recovers from bit errors, negating the need for retransmission MAPS Automation that simplifies policy-based monitoring and alerting ClearLink Diagnostics Cable and optic diagnostics that simplify the deployment and support of large fabrics Flow Vision Identifies, monitors, and analyzes the performance of specific flows or frame types COMPASS Simplifies SAN configuration and maintains consistency in operational behavior VM
  22. 22. 21 © Copyright 2017 FUJITSU IO Insight
  23. 23. 22 © Copyright 2017 FUJITSU Gain Deep Visibility with IO Insight Extend Standard Brocade Fabric Vision capabilities with IO Insight Proactively monitor storage device IO performance and behavior through built-in instrumentation to gain deep insight into problems and ensure service levels Advanced IO Monitoring Monitor storage device I/O workloads and behaviors IO Performance Diagnostics Identify the source of storage device performance degradation
  24. 24. 23 © Copyright 2017 FUJITSU VM VM VM VM VM VM No taps, no downtime, no disruption Non-disruptively monitor IO workloads of interest and obtain insights into storage performance VM VM
  25. 25. 24 © Copyright 2017 FUJITSU Brocade IO Monitoring Tools IO Insight compared to Fabric Vision and AMP Monitoring, management, and diagnostic tools  Dashboard views  Live monitoring  Pre-defined, threshold- based rules/policies Gen 6 storage IO-level monitoring  SCSI R/W response/latency monitoring  Alert for storage outliers  Identify latency and congestion  100% non-disruptive Use cases:  Flow-level monitoring of a storage port  Visibility to understand storage performance  Monitoring SLA compliance Gen 5 and Gen 6 end-to-end IO monitoring  Full visibility of all SCSI commands  Alert for host, fabric, and storage outliers/individual IO flows  Automatic LUN/flow learning  Direct fabric latency monitoring  100% non-disruptive Use cases:  Monitoring mission-critical workloads  Extensive diagnostics and troubleshooting  Highly scalable from device level to fabric level Fabric Vision on Gen 5 Fabric Vision with IO Insight Analytics Monitoring Platform
  26. 26. 25 © Copyright 2017 FUJITSU Date Center Extension
  27. 27. 26 © Copyright 2017 FUJITSU  Resiliency and Availability  Security  Visibility and Management of Network Connectivity and Application Performance  Performance at Scale Data Center to Data Center or to DR site Brocade’s innovative extension solution Primary Data Center Brocade Technology DR/ Secondary Site High-Speed FC and IP Storage Replication.
  28. 28. 27 © Copyright 2017 FUJITSU NVMe over Fibre Channel
  29. 29. 28 © Copyright 2017 FUJITSU Why Fibre Channel for NVMe? Brocade Fibre Channel is NVMe Ready Today! The only purpose-built fabric for storage Industry Leading Low Latency NVMe over Fibre Channel yields 55% latency reduction Scalability Beyond the Rack Low Risk Deployment Faster than 25Gb Ethernet Optimized for heavy storage workloads Leverages existing FC infrastructure and Concurrently run NVMe Speeds matched to the PCIe bus for maximum performance
  30. 30. 29 © Copyright 2017 FUJITSU NVMe over Fibre Channel “for dummies” http://www.dummies.com/go/nvmeoverfibrechannelfordummiesbrocadespecialedition
  31. 31. 30 © Copyright 2017 FUJITSU The Brocade – Fujitsu Partnership Your Partners for Data Center Modernization

×