SlideShare une entreprise Scribd logo
1  sur  53
Télécharger pour lire hors ligne
Drafting Sanitary and Plumbing Layout and Details
288
Content Standard Performance Standard
The learner demonstrates
understanding of concepts and
underlying principles in drafting
sanitary and plumbing layout and
details.
The learner independently drafts
sanitary and plumbing layout and
details following the job
requirements.
Quarter IV Time Allotment: 16 hrs.
MODULE 6
Drafting Sanitary and Plumbing Layout and Details
Introduction
This module is designed to familiarize students with the concept of
sanitary disposal of waste and the principle of introducing clean water in to the
residential unit from the source. It will also help the students understand the
intricacy of designing and planning a sanitary plumbing and sewerage layout.
It also familiarizes them with the different abbreviations and symbols used in
drafting of sanitary and plumbing layout, the specification materials used for the
construction and the different kinds of fittings intended for a sound construction
of the layout.
Plumbing drawings are prepared to a very small-scale. Therefore
schematic symbols are used for drawing plumbing lines, fixture and other
components as they actually appear. These symbols are used to show the type
and location of fixtures, valves, joints and other plumbing devices.
Objectives:
At the end of this module, you are expected to:
 draft water distribution system; and
 draft sanitary and storm drainage
Drafting Sanitary and Plumbing Layout and Details
289
At this point, you are
heading into meaningful
activities and learning
encounters. Complete the
exercises and answer the
suggested worksheets to
experience lifelong, practical
learning that awaits at the end
of this module.
ENJOY YOUR JOURNEY!
*****
Pre-assessment: Multiple Choice
Direction: Choose the letter of the correct answer. Write your answer in
the space provided before each number.
_____1. A kind of fitting used to straight section pipes.
a. elbows b. coupling c. cross d. tee
_____2. How is hot and cold water distributed from the source to the different
parts of the building?
a. by pressurizing the source c. by mixing hot and cold water
b. by raising water temperature d. by chemical means
_____3. Used to close systems and to connect pipes that have to be
disassembled occasionally.
a. unions b. plug valve c. nipples d. reducers
_____4. The preceding plumbing symbol indicates a --
a. coupling c. straight cross
b. safety valve d. gate valve
_____5. A fitting used to change direction of a pipe line either 90 degrees or
45 degrees.
a. T b. cross c. elbows d. couplings
_____6. Used to close the end of a pipe.
a. cap b. plug c. bushing d. unions
_____7. The storm drainage is considered a part of the –
a. plumbing system. c. foundation system.
b. electrical system. d. elevation system.
_____8. Used to close an opening in a fitting.
a. cap b. plug c. bushing d. unions
_____9. Which of these common plumbing symbols/abbreviations indicate a
Drafting Sanitary and Plumbing Layout and Details
290
junction box?
a. JXB b. JBox c. JB b. JBX
_____10. The ideal or suggested size in constructing the septic tank with a 15
number of people is______.
a. depth- 1:20, W-1:0, L- 2:0 c. depth 1:50 , W- 1:20, L-1:50
b. depth- 1:50, W-1:5, L-150 d. depth 2:50, W-1:50, L -2:50
_____11. Used to reduce the size of an opening.
a. bushing b. unions c. cap d. plug
_____12. A network of pipes and fittings that carry off wastes and each
plumbing fixture is titled with the appropriate pipe and fitting.
a. Sanitary installation c. Drainage system
b. Polyvinyl pipe and fittings d. Sanitary and storm drainage
_____13. Used to close systems and to connect pipes that are to be
disassembled occasionally.
a. cap b. plug c. bushing d. unions
_____14. A water distribution system shown in an elevation, on plan and on
isometric using the different symbols.
a. isometric draft c. isometric water system
b. water system diagram d. schematic drawing
_____15. Which is NOT a type of valve:
a. Gate valve c. Check valve
b. Globe valve d. Metal valve
Skills Evaluation
Direction: Listed below are some of the most important skills that you must
gain in order to draft a quality floor plan. On the right side of the matrix lists the
skills expected of you to master. Rate yourself by checking “Not much”, if you
are not so familiar yet, “A little” and/or “A lot”, if you are already familiar with the
skills. Don’t feel bad if you checked “Not Much” in all of the skills. Keep in mind
that this is being administered to determine your pre-entry knowledge of and
skills on the lesson to be presented.
Skills in drafting water distribution system Not Much A little A lot
 I can draft hot and cold water distribution
systems according to Plumbing and
Water Codes
 I can indicate signs and symbols
according to sanitary and plumbing
requirements
Drafting Sanitary and Plumbing Layout and Details
291
Learning Goals and Targets:
After reading the introduction and carefully answering the pre
assessment instrument, you might have ideas of what you will be dealing with
in this module. Now prepare to set your goals and targets for this module by
completing the activity below. Write your answer in your notebook.
My goals are:
My targets are:
Goal 4
Goal 3
Goal 2
Goal 1
Target 1
Target 2
Target 3
Drafting Sanitary and Plumbing Layout and Details
292
Lesson 1: Draft Water Distribution Systems
This lesson is designed to familiarize you to draft the proper distribution
of water system (hot and cold water) and the signs and symbols used which
are based on the standard water code of the Philippines.
Operational Definition of Terms:
Aluminum is a lightweight but relatively strong metal often alloyed with copper
to increase hardness and strength.
Gate Valve is usually chosen for locations where it is left completely open most
of the time because it offers the least resistance to the flow of water.
Diagrammatic Layout is used for drafting layout in architectural plans.
Nipples are short pieces of pipes threaded on both ends.
Plumbing refers to the water supply and drainage of wastewater sewage.
Plumbing system refers to the supply pipes that carry fresh waste water
under pressure from a public water supply or individual wells to fixtures.
Reducer is used to connect straight section pipes of different sizes.
Scale Layout is used for drafting large pipes.
Overview
One of man’s essential needs is water. He could live for days without
food but not without water. Water appears in its natural state (liquid) or solid
(ice) and gas (vapor) or steam. It is 830 times heavier than air but is 133 times
lighter in its gaseous state. This can be sourced from: rain water, natural
surface water and underground water.
Water is a necessity. It is conveyed from the source to the household
through a system of pipes.
Water distribution systems for residential and commercial buildings are
conveyed thru pipes, a PVC, Cast Iron or G.I. pipe.
Hot and cold water is supplied to the buildings by a series of pipes
connected from the source under pressure to the building fixtures thru a water
line distribution system.
Know
Drafting Sanitary and Plumbing Layout and Details
293
Pipes used for water line distribution systems may be classified as:
1. Steel and wrought iron pipe
2. Cast iron pipe
3. Seamless brass and copper pipe
4. Copper tubing
5. Special pipes such as PVC (Polyvinyl Chloride), Aluminum and Stainless
Steel pipes, and CPV’C (Chlorinated Polyvinyl Chloride) pipe
Water main refers to the public sewer system along the streets, or laid
underground where the service to the house is connected. Water coming from
it is under pressure but normally could serve only houses of moderate height.
A pump is installed to augment the pressure that forces the water to move inside
the pipe.
The size of the service pipe is determined by the demand for water. A
maximum demand is one factor, or the maximum water discharge for plumbing
fixtures and the probable demand is another, which is the peak demand or peak
load.
Connection of Pipes
Pipes are connected by methods dependent upon the material and the
demands of service. Steel, brass or bronze pipes are normally threaded and
screwed into coupling and fitting. Fittings are used to join adjacent lengths of
pipes and to provide changes of direction, and branch connections at any angle
and to effect a change in size.
Connections
1. Threaded connections
2. Soldered fittings
3. Connection by bolded flanges
4. Solvent cement weld connections
Common types of fittings
1. Screwed fittings
2. Welded joints
3. Flanged joints
4. Solder joints
5. Slip fittings (for plastic pipes)
Valves
1. Gate valves
2. Globe valves
3. Check valves
Drafting Sanitary and Plumbing Layout and Details
294
4. Pressure reducing valves
5. Safety valves
Valves are specified by giving the nominal size, material and ride.
Kinds of Fittings
1. Elbows are used to change direction of a pipeline either 90 degrees
or 45 degrees.
2. Tee connects three pipes.
3. Cross connects four pipes.
4. Couplings are used to connect straight section pipes.
5. Reducers are used to connect straight section pipes of different sizes.
6. Nipples are short pieces of pipes threaded on both ends and classified
as close nipple and short nipple.
7. Cap is used to close the end of a pipe.
8. Plug is used to close an opening in a fitting.
9. Bushing is used to reduce the size of an opening.
10. Unions are used to close systems and to connect pipes that are to be
disassembled occasionally.
Systems of Drawing Pipe Layout
1. Scale Layout are used for large pipes
2. Diagrammatic lay out are used for architectural plans.
Drafting Sanitary and Plumbing Layout and Details
295
Drafting Sanitary and Plumbing Layout and Details
296
Suggested Activity 1
Directions: Read each item carefully. Identify the correct answer and write
it on a separate sheet of paper.
__________ 1. It is used to stop or regulate the flow of fluids.
__________ 2. It is used to limit the flow of fluids to one direction only.
__________ 3. It is used to connect three pipes.
__________ 4. It is used to connect straight section pipes of different sizes.
__________ 5. They are short pieces of pipes threaded at both ends.
__________ 6. They are full sized straightway openings that offer small
resistance to the flow of fluids.
__________ 7. It is used to join adjacent length of pipes.
__________ 8. It is used to close the end of a pipe.
__________ 9. It is used to close an opening or fitting.
__________ 10. It is a kind of layout for pipes used in architectural plans.
Group Activity: Identification of pipe fittings and pipe materials
Directions:
Note: The teacher shall distribute pictures of plumbing fixtures and
fittings.
 Work in groups of 3 to 5 (depending upon the number of students in
the class) and chose a leader.
 Identify the different kinds of:
Process
Drafting Sanitary and Plumbing Layout and Details
297
o pipes used in plumbing;
o materials used; and
o different kinds of pipes fittings and flanges.
 Write a description in a piece of paper, each of the above in terms of
its characteristics and uses.
 Report your outputs to your teacher to assess and/or check your
learning of the targeted knowledge and skills.
The plumbing system is important to the designer or draftsman. Although
plumbing plans may be omitted on small residential dwellings, they are always
included in larger projects for small residences; the plumbing layout is left to the
contractor or the owner to decide.
A plumbing system performs two major functions which are:
1. For Water Distribution
2. Sewage Disposal
Water distribution systems, whether hot or
cold, are distributed by pipes from the source to
the house. Amenities as discussed earlier, when
tracing the path of the supply of water and
fixtures fittings, the architectural designer uses
symbols to indicate the distribution system and
the different fixtures. The water distribution
system is shown in an elevation, on plan and on
isometric using the different symbols, hence this
is called a schematic drawing.
In drawing the layout, here are the common
symbols used for cold water line and sanitary
layout.
Know
COMMON PLUMBING
SYMBOLS
Drafting Sanitary and Plumbing Layout and Details
298
Like most architectural drawings, plumbing drawings are drawn to a small
scale. It would be unrealistic to draw all fixtures and lines on the drawing paper.
Therefore schematic symbols are used for various plumbing fixtures and lines.
They are used to show the type and location of fixtures, joints values and other
devices.
The difference in appearance of an orthographic drawing of fixtures and
other devices with that of a schematic drawing is shown in the figure.
SANITARY & PLUMBING
SYMBOLS
LEGEND/ABBREVIATION
Water Closet WC
Vent at Ceiling VAC
Vent Stack thru Roof VSTR
Cold Water Line CWL
Hot Water Line HWL
Concrete Drain Pipe CDP
Cast Iron Soil Pipe CISP
Down Spout DS
Cast Iron Vent Stack CISS
Cast Iron Vent Stack CIVS
Vent At Ceiling VAC
Vent Stack Thru Roof VSTR
Catch Basin CB
Junction Box JB
Water Meter WM
Galvanize Iron Pipe Water Line GIPWL
Cold Water Riser CWR
Cold Water Down Feed CWDF
Fire Line FL
Deck Drain DD
Canopy Drain CD
Sprinkle Riser SPR
Dry Stand Pipe Riser DSPR
Fire Hose Cabinet FHC
Lavatory LAV
Water Closet WC
Floor Drain FD
Clean Out CO
Drafting Sanitary and Plumbing Layout and Details
299
Drafting Sanitary and Plumbing Layout and Details
300
Drafting Sanitary and Plumbing Layout and Details
301
SYMBOL ELEVATION PICTORIAL
Double Brach Elbow –
DBL EL
Straight Cross - STX
Safety valve – SFTY V
Gate Valve – GT V
Hand Valve – HND V
Pipe Outlet Up - P
Pipe Outlet Down - P
Coupling - CPLG
Elbow 90° - EL
Elbow 45° - EL
Tee 90° - T
Lateral 90° - LAT
Clean Out - CO
Reducer - RED
Drafting Sanitary and Plumbing Layout and Details
302
SYMBOL ELEVATION PICTORIAL
Flanged Fittings – FL FT
Screwed Fittings – SC FT
Bell and Spigot Fittings – BL/SP
FT
Welded Fitting – WLD FT
Soldered Fitting – SLD FT
Expansion Joint – EXP JT
Motor Operated Vehicle – MOP
V
Meter – M
Floor Drain - FD
Cess Pool – CP
Dry Well - DW
Septic Tank – SEP TNK
SEPTIC – TANK Distribution Box
– SEP TANK DIS BX
SUMP PIT - SP
Drafting Sanitary and Plumbing Layout and Details
303
Suggested Activity 2
A. Draw the symbols for the following terms on a separate sheet of paper.
1. Faucet 6. Hose bib
2. Water closet 7. Lavatory
3. Gate valve 8. Water meter
4. Shower 9. Kitchen sink
5. Floor drain 10. Clean out
B. Classification: Given the word pool below, try to find where each of these
word belongs.
PIPES PIPE CHECK
FITINGS VALLES
C. Draft a water line layout for a Toilet and Bath
Procedure:
1. From the given plan of a T&B, indicate the location of bathroom fixtures by
drawing the symbols of each on the place where they think is the best location.
Process
FLARED TEE SAFETY ELBOW CAP GATE
REDUCER FERRULE BUSHING CROSS
Drafting Sanitary and Plumbing Layout and Details
304
2. In as much as the kitchen is adjacent to the toilet and bath, naturally the source
of water supply comes from the same direction. Try to draw the layout of the water
supply line to the different fixtures they have identified.
Try to draw the water supply line to indicate the pipe fittings used and the
different fixtures and the water flow.
3. After highlighting the pipe fittings used and indicated the water supply
source and its flow, darken the supply line and indicate the pipe and fixture
specifications by writing them beside the fixtures as indicated by the arrow.
Then, write down the legend for identification.
Drafting Sanitary and Plumbing Layout and Details
305
A typical diagram of the plumbing system of a single detached one-storey
dwelling units.
The Water Line Layout
The water distribution system is the network of pipes and fittings for
conveying water to the plumbing fixtures while the system of pipes and fittings for
carrying off wastes is referred to as sanitary installation
The building water entrance pipe is connected to the street by means of a
corporation cock, if the water is supplied by the community. The amount of water
passing thru the water service is measured by the water meter. If water service is
supplied thru a deep well, a water meter is not necessary. From this, the water
pipes branch out to the fixtures inside the residential unit requiring water.
Clean water lines are represented on a plan by a visible line and two dashes,
while sanitary lines are represented by a bold continuous line. The fixtures are
indicated by their common symbols. Storm drainage lines are drawn with two
invisible lines that run parallel to each other. While vent pipes are bold hidden lines.
The operation of the basic plumbing system is readily understood through
the diagram shown here.
To get water to a structure for use by the tenants and to remove sewage
and unwanted water is the purpose of a plumbing system.
Drafting Sanitary and Plumbing Layout and Details
306
A Sample Plumbing Layout
A Typical Plumbing System
Drafting Sanitary and Plumbing Layout and Details
307
Drafting Sanitary and Plumbing Layout and Details
308
Water Pipes and Fittings Required For Installing Commonly
Used Plumbing Fixtures
Drafting Sanitary and Plumbing Layout and Details
309
A typical installation of a water distribution using PVC pipes with G.I.
Pipes for in-house is done with PVC pipes adapter fittings. To obtain
watertight joints, solvent cement is applied.
uPVC Adafter Fitting for uPVC-to-Galvanized Iron Water
Piping Connectors
Drafting Sanitary and Plumbing Layout and Details
310
Shown below are the procedure on how to lay-out the plumbing system in
the floor plan.
Procedure:
1. From the plan shown below, indicate the location of water fixtures by
drawing their symbols on the place you think is the most suitable location
for each. You too, shall indicate the water supply source from the street
water branch.
ReflectandUnderstand
Drafting Sanitary and Plumbing Layout and Details
311
2. After locating and indicating the location of the fixtures, draw the water line
connection from the water source. In addition, try to indicate the position of
the water meter and the check valve based on their layout and the source
of water supply.
3. Draw the water line layout of the pipe fittings and the fixtures to show the
different kinds of fittings use, and write down the specifications of the
material used.
BEDROOM
BEDROOM
DINE/KIT
KS
LIVING
Drafting Sanitary and Plumbing Layout and Details
312
4. After indicating and writing down the material used for the pipe and fittings,
5. Darken the water layout and write down the abbreviations on the fixtures
together with the legend to distinguish the different water fixtures.
LEGEND
F Faucet
GV Gate Valve
HB Hose Bibb
WM Water Meter
WC Water Closet
SHO Shower Head
LAV Lavatory
GIP Galvanized Iron Pipe
Drafting Sanitary and Plumbing Layout and Details
313
Directions: From the plan shown below, sketch a clean water line layout.
Specific Requirements:
1 faucet
1 shower head
1 lavatory
1 water closet
Transfer
Drafting Sanitary and Plumbing Layout and Details
314
Procedure:
1. From the preceding water line layout, determine which axis is to be used
to present the diagram
2. Indicate the height of water fixtures according to scale ratio used and
based on accepted architectural standards.
Transfer
Drafting Sanitary and Plumbing Layout and Details
315
3. Layout water distribution system and indicate location of fittings fixtures.
4. Finalize drawing and draw legend
Drafting Sanitary and Plumbing Layout and Details
316
Summative Test
Directions: From the plumbing layout drawn, draft the isometric plumbing diagram.
Use standard height.
Transfer
Drafting Sanitary and Plumbing Layout and Details
317
Lesson 2. Draft Sanitary and Storm Drainage
The sanitary installation is referred to as the network of pipes and fittings
that carry off wastes and each plumbing fixture is titled with the appropriate pipe
and fitting. The discharges are conveyed to the septic vault.
The storm drainage system, on the other hand, consists of pipes, fittings,
catch basins, area drain and is intended for getting rid of water from the building
roof and its surrounding and is conveyed to the street sewer. The storm drainage
is considered part of the plumbing system.
The pipe used for sanitary and storm drainage most common to
homeowners and contractors are the plastic pipe or Polyvinylchloride (PVC) pipes
and the concrete pipe for area drain.
Skills Evaluation
Direction: Listed below are some of the most important skills that you must gain
in order to draft a quality floor plan. On the right side of the matrix lists the skills
expected of you to master. Rate yourself by checking “Not much”, if you are not
so familiar yet, “A little” and/or “A lot”, if you are already familiar with the skills. Don’t
feel bad if you checked “Not Much” in all of the skills. Keep in mind that this is
being administered to determine your pre-entry knowledge of and skills on the
lesson to be presented.
Skills in drafting sanitary and storm drainage Not Much A little A lot
 I can draw sewerage plan layout according to
Plumbing Code
 I can draft storm drainage plan according to
Plumbing Code
 I can draw details and symbols according to
sanitary and plumbing requirements
Learning Goals and Targets:
After reading the introduction and carefully answering the instrument, you
might have ideas of what you will be dealing with in this module. Now prepare to
set your goals and targets for this module by completing the activity below. Write
your answer in your notebook.
Know
Drafting Sanitary and Plumbing Layout and Details
318
My goals are:
My targets are:
Overview
Wastewater is discharged by gravity through the disposal system. All pipes
in this system therefore must slant in a downward direction so the weight of the
waste will cause it to move down. Because of this gravity flow, waste lines are
larger than water lines. The stacks are the vertical lines while the branches are the
horizontal lines. Vents are also provided for air circulation and to permit sewer
gases to escape thru the roof. This equalizes the air pressure in the drainage
system.
The wastewater flows starting at the fixture trap, which is provided to stop
gases from entering the building and each fixture has a separate trap or seal to
prevent backflow of sewer gas, through the fixture branches to the main sewer line.
Waste stacks carry only wastewater while solid wastes runs thru the soil
lines, which are the largest in the system and are flushed with water after each use.
Goal 4
Goal 3
Goal 2
Goal 1
Target 1
Target 2
Target 3
Drafting Sanitary and Plumbing Layout and Details
319
Piping systems are vital to modern society. Some systems may be complex;
others may be simple such as in a residential dwelling unit. But they share some
common elements, whether they are steel, plastic, copper pipes or tubing.
Sanitary and storm drainage for residential dwelling are either wrought –
iron pipes, Polyvinylchloride (PVC) pipes and for drainage is either concrete pipe
or PVC pipe. The more common today is the unplasticized Polyvinylchloride (uPVC)
pipe.
Polyvinyl pipe and fittings are available in commercial length of 3.0 meters
and also available in schedule 40 and 80. They are usually assembled with slip
joint fittings and solvent, both PVC and chlorinated Polyvinylchloride (cPVC) pipes
are commonly available in sizes ranging from ½’ to 4” inside diameter.
The Sewage Disposal System
Absence of a good sewage disposal system can result to contamination of
water and water-borne diseases. It is important to value a good disposal system.
There are different types of sewage disposal system, from the old to the
more scientific ones:
1. Cesspool
2. Privy
3. Septic Tank
4. Public Sewer line
The sanitary system is of two types: the intercepting and the tributary or
contributing sewer. The intercepting type is constructed with concrete pipes while
the tributary sewer is laid in an open trench and is made of vitrified clay or bricks.
Water Lines Plumbing Elevation
Drafting Sanitary and Plumbing Layout and Details
320
Drafting Sanitary and Plumbing Layout and Details
321
Drafting Sanitary and Plumbing Layout and Details
322
The Septic Tank
The septic system converts solid wastes into liquid by bacterial action, the
wastes flow into a septic tank some distance away from the house. The liquid waste
flows thru to the sewer line while the sludge remains at the digestion chamber of
the tank.
The septic tank is constructed with reinforced concrete, and it should be
located at a safe distance from the source of potable water, and it should also be
airtight.
The size and type of the system varies according to the number of people
served, the contour and soil type.
Inlet Outlet
Inlet
Drafting Sanitary and Plumbing Layout and Details
323
Types of Sanitary Fittings used in plumbing System of Septic Vaults
SANITARY FITTING
Drafting Sanitary and Plumbing Layout and Details
324
The Size of the Septic Tank
The septic tank should be constructed as to have enough room for
accumulated sludge.
Here are some of the suggested sizes.
NUMBERS OF
PERSONS SERVED
INSIDE DIMENSION OF DIGESTION CHAMBER
D- DEPTH W- WIDTH L - LENGTH
METERS METERS METERS
10 1.20 0.90 1.30
15 1.20 1.00 2.20
20 1.20 1.25 2.50
25 1.20 1.40 2.80
30 1.30 1.50 3.00
35 1.30 1.60 3.20
40 1.40 1.65 3.30
45 1.40 1.75 3.50
50 1.50 1.80 3.60
55 1.50 1.85 3.90
70 1.50 2.00 4.00
80 1.60 2.20 4.40
90 1.80 2.30 4.50
100 1.80 2.50 5.00
Sizes of Septic Vault
The Typical Detail of a Septic Tank
Drafting Sanitary and Plumbing Layout and Details
325
A. Direction: Write down the abbreviations of the following terms on a
separate sheet of paper.
Terminologies:
1. Concrete pipe
2. Catch basin
3. Area drain
4. Septic vault
5. Galvanized iron pipe
6. Wrought iron pipe
7. Vent stack thru roof
8. Polyvinyl chloride
9. Chlorinated polyvinyl chloride
10. Outside diameter
B. Draft Household Sanitary Layout:
1. With the given floor plan, you are supposed to draw the sanitary layout for
this housing unit. Indicate first where you would locate your septic vault
outside the building.
Process
Drafting Sanitary and Plumbing Layout and Details
326
2. After locating the place where you would construct your septic vault, draw
and indicate the location of the different storm drainage fixtures.
3. Indicate the location of the different sanitary fixtures by drawing their
symbols on the area where they are best located. Then draw the layout,
connecting all these fixtures and to the septic vault with the sewer line
connecting to the street sewer.
Drafting Sanitary and Plumbing Layout and Details
327
4. After drawing the layout, indicate the different pipes and fittings used by
drawing their symbols on the sewer line layout and write down also the
material specification for the fixtures used.
Drafting Sanitary and Plumbing Layout and Details
328
The Drainage System
The drainage system is sometimes referred to as the DWV or the
drainage, the waste and the vent system. The construction and installation of this
must conform to the provisions of the building and plumbing codes. Some of the
general requirements are as follows:
1. Pipes must be fitted and tightly connected to avoid leakage.
2. Ventilation must convey gases to the atmosphere.
3. Each fixture must be provided with a suitable trap to prevent backflow or
gases.
4. The fixture must be re-vented to avoid siphoning of the water seal.
5. Drainage pipes should be sloped or graded properly.
6. Drainage pipes should be provided with adequate clean out for maintenance
purposes.
The waste pipe which receives the discharge of any fixture except water
should be installed at 2% or 20mm slope per meter run. The size of the waste pipe
is to be considered in the installation as this pipe serves fixture discharges. And
when the pipe must be opened in case of trouble, a clean-out should also be
installed and must be accessible to the plumber.
Slope or Pitch
The soil pipe receives and conveys drainage of water closets and other
fixtures to the house drain. It should be properly concealed or embedded and
should be placed in a manner that the branches should be as short as possible. As
a rule, it should extend and terminate through the roof of the building.
Know
Drafting Sanitary and Plumbing Layout and Details
329
Second Floor
First Floor
The House Drain
The sanitary drain only receives discharges of sanitary and domestic wastes
only while the storm drain receives storm, clear water or surface water wastes.
Drafting Sanitary and Plumbing Layout and Details
330
A typical house drain is shown below.
The House Sewer
The portion of the horizontal drainage system starts from the outer surface
of the dwelling and terminates at the public sewer. A minimum size of 150mm (6ӯ)
is used for residential dwellings.
Drafting Sanitary and Plumbing Layout and Details
331
The Storm Drain
It is the part of the plumbing system which conveys rain or storm water into
the street gutter. It is of two types: the inside storm drain and the outside storm
drain. Layout of the two is shown in the following illustrations.
Drafting Sanitary and Plumbing Layout and Details
332
A Typical Catch Basin Detail
The Catch Basin
The catch basin water discharges from the roof and conveys it to the
storm drainage line. It is more or less of the same use as the area drain. It
also serves as a manhole for cleaning.
Drafting Sanitary and Plumbing Layout and Details
333
Directions: From the plan shown below, sketch the sewer line from the fixtures to
the street sewer. Label the drawing.
Requirements:
1 – Kitchen Sink
1 – Water Closet
1 – Floor Drain
1 – Septic Vault
1 – Lavatory
ReflectandUnderstand
Drafting Sanitary and Plumbing Layout and Details
334
Summative Test
Directions: From the layout you drafted. Draw a sanitary and plumbing layout and
details following the job requirement. Use approved standard height of amenities.
Note: You are provided with a copy of the plan.
Requirements:
1- Kitchen Sink
1- Water Closet
1- Floor Drain
1- Septic Vault
Transfer
335
I. Enrichment Activity: Draft a septic vault for 5 – 7 persons
Procedure:
1. Refer from the table on recommended sizes of septic vaults. See if
the number of persons in the household fits in the data for
recommended size of vault.
2. Take down the measurements: width, height and length. Transfer
such measurement on your drawing paper.
3. Draw the outline of the septic vault with your pencil using light
guidelines only. As you draw the outline, draw also the thickness of
the sides of the septic vault, taking into consideration the thickness
of CHB used for walls partitions.
4. Indicate also the location of the manhole and the manhole cover.
After drawing the outline re-checked your measurements, write down
your dimensions and you are ready to draw the reinforcing bars. You
may draw your rebars covering the whole area of the vault or you can
have a portion of it only.
336
5. Draw the vertical and horizontal bars for the reinforcement of the
septic vault. The standard distances and size of the rebars are 12mm
Ø for vertical bars and 10mmØ for horizontal bars. For the slabs on
top of it would be 10mm Ø spaced at 20cm on both ways of the slab.
6. Draw only the portion you wish to show the detail of the
reinforcements. Indicate now the inlet valve, in the digestion chamber
its position or location and its size, together with the outlet valve.
7. From the plan you have already drawn, project dimensions
downward and draw a longitudinal section of your septic vault.
Remember the thickness and measurements of the plan should be
the same as your section.
337
8. With the data on its depth you have gathered, layout the depth of the
septic vault, including its foundation and footing. Indicate the location
of your inlet and outlet valves which should have a distance from the
bottom of the slab of about 30 cm. for the air space and the water
level.
9. Draw vertical and horizontal bars on the sides and on the footing.
10.Review the drawing, its dimensions and measurements. Finalize the
drawing by darkening the lines with a technical pen. Write down the
material specifications and construction notes.
CROSS
338
II. Drafting Sanitary and Plumbing Layout and Details
Directions: Draft a catch basin detail with the following requirements:
1. Indicate the size of catch basin according to structural and design standard.
2. Draft outlines of both plan and sectional elevation.
3. Draft outlines of pipes and slope of pipes
4. Darken lines or ink drawing .draft dimensions and specifications.
339
Post-Assessment
Answer the post assessment below to determine whether
there is significant increase in your understanding of the lesson on
drafting water distribution, sanitary and storm drainage systems. The
feedback to this post assessment is appended on page ____
Good Luck!
Direction: Choose the letter of the correct answer. Write your answer in the space
provided to each number.
_____1. A kind of fitting used to straight section pipes.
a. elbows b. coupling c. cross d. tee
_____2. How is hot and cold water distributed from the source to different parts of the
building?
a. by pressurizing the source c. by mixing hot and cold water
b. by raising water temperature d. by chemical means
_____3. Used to close systems and to connect pipes that have to be
disassembled occasionally.
a. unions b. plug valve c. nipples d. reducers
_____4. The preceding plumbing symbol indicates a --
a. coupling. c. straight cross
b. safety valve. d. gate valve.
_____5. A fitting used to change direction of a pipe line either 90 degrees or
45 degrees.
a. T b. cross c. elbows d. couplings
_____6. Used to close the end of a pipe.
a. cap b. plug c. bushing d. unions
_____7. The storm drainage is considered a part of the –
a. plumbing system. c. foundation system.
b. electrical system. d. elevation system.
340
_____8. Used to close an opening in a fitting.
a. cap b. plug c. bushing d. unions
_____9. Which of these common plumbing symbols/abbreviations indicate a
junction box?
a. JXB b. JBox c. JB d. JBX
_____10. The ideal or suggested size in constructing the septic tank with a 15
number of people is______.
a. depth- 1:20, W-1:0, L- 2:0 c. depth 1:50 , W- 1:20, L-1:50
b. depth- 1:50, W-1:5, L-150 d. depth 2:50, W-1:50, L -2:50
_____11. Used to reduce the size of an opening.
a. bushing b. unions c. cap d. plug
_____12. A network of pipes and fittings that carry off wastes and each plumbing fixture
is titled with the appropriate pipe and fitting.
a. Sanitary installation c. Drainage system
b. Polyvinyl pipe and fittings d. Sanitary and storm drainage
_____13. Used to close systems and to connect pipes that are to be disassembled
occasionally.
a. cap b. plug c. bushing d. unions
_____14. A water distribution system shown in an elevation, on plan and on
isometric using the different symbols is called _________.
a. isometric draft d. isometric water system
b. water system diagram c. schematic drawing
_____15. Which is NOT a type of valve:
a. Gate valve c. Check valve
b. Globe valve d. Metal valve

Contenu connexe

Tendances

Building Services Report
Building Services ReportBuilding Services Report
Building Services ReportJoanne Yunn Tze
 
Interior specifications
Interior specificationsInterior specifications
Interior specificationsmlasantosh
 
Vertical transportation important
Vertical transportation importantVertical transportation important
Vertical transportation importantMuhammad Muhyuddin
 
Temporary structures
Temporary structuresTemporary structures
Temporary structuresDivya Vishnoi
 
industrialised building systems_achah
industrialised building systems_achahindustrialised building systems_achah
industrialised building systems_achahAisyah Asyikin
 
Reading floor plans
Reading floor plansReading floor plans
Reading floor plansjayneross
 
Electrical wiring system
Electrical wiring systemElectrical wiring system
Electrical wiring systemshweta saini
 
Telecommunication for high rise building
Telecommunication for high rise buildingTelecommunication for high rise building
Telecommunication for high rise buildingJäkê Čhŷį Śêrñ
 
Building Services Electrical (MEP)
Building Services Electrical (MEP)Building Services Electrical (MEP)
Building Services Electrical (MEP)Manoj Mawle
 
BS 2 Escalators arrangement
BS 2 Escalators arrangementBS 2 Escalators arrangement
BS 2 Escalators arrangementEst
 
BTECHN PROJECT 2 Final report (GROUP)
BTECHN PROJECT 2 Final report (GROUP)BTECHN PROJECT 2 Final report (GROUP)
BTECHN PROJECT 2 Final report (GROUP)ong93
 
Module 6 module 4 draft sanitary and plumbing layout and details
Module 6   module 4 draft sanitary and plumbing layout and details Module 6   module 4 draft sanitary and plumbing layout and details
Module 6 module 4 draft sanitary and plumbing layout and details Gilbert Bautista
 
Curtain wall introduction & requirements
Curtain wall introduction & requirementsCurtain wall introduction & requirements
Curtain wall introduction & requirementsArshad khan
 
R-22 Walls and Insulating for the Future
R-22 Walls and Insulating for the FutureR-22 Walls and Insulating for the Future
R-22 Walls and Insulating for the FutureLorne Ricketts
 
Building services group report
Building services group report Building services group report
Building services group report XingYue0907
 
Roof trusses
Roof trussesRoof trusses
Roof trussesRavi Pa
 

Tendances (20)

Building Services Report
Building Services ReportBuilding Services Report
Building Services Report
 
PIPE SYSTEMS1
PIPE SYSTEMS1PIPE SYSTEMS1
PIPE SYSTEMS1
 
Interior specifications
Interior specificationsInterior specifications
Interior specifications
 
Vertical transportation important
Vertical transportation importantVertical transportation important
Vertical transportation important
 
Temporary structures
Temporary structuresTemporary structures
Temporary structures
 
industrialised building systems_achah
industrialised building systems_achahindustrialised building systems_achah
industrialised building systems_achah
 
Stairs
StairsStairs
Stairs
 
Lifts & Escalators
Lifts & EscalatorsLifts & Escalators
Lifts & Escalators
 
Reading floor plans
Reading floor plansReading floor plans
Reading floor plans
 
Electrical wiring system
Electrical wiring systemElectrical wiring system
Electrical wiring system
 
Telecommunication for high rise building
Telecommunication for high rise buildingTelecommunication for high rise building
Telecommunication for high rise building
 
Building Services Electrical (MEP)
Building Services Electrical (MEP)Building Services Electrical (MEP)
Building Services Electrical (MEP)
 
BS 2 Escalators arrangement
BS 2 Escalators arrangementBS 2 Escalators arrangement
BS 2 Escalators arrangement
 
BTECHN PROJECT 2 Final report (GROUP)
BTECHN PROJECT 2 Final report (GROUP)BTECHN PROJECT 2 Final report (GROUP)
BTECHN PROJECT 2 Final report (GROUP)
 
Module 6 module 4 draft sanitary and plumbing layout and details
Module 6   module 4 draft sanitary and plumbing layout and details Module 6   module 4 draft sanitary and plumbing layout and details
Module 6 module 4 draft sanitary and plumbing layout and details
 
Curtain wall introduction & requirements
Curtain wall introduction & requirementsCurtain wall introduction & requirements
Curtain wall introduction & requirements
 
Window topic 8
Window topic 8Window topic 8
Window topic 8
 
R-22 Walls and Insulating for the Future
R-22 Walls and Insulating for the FutureR-22 Walls and Insulating for the Future
R-22 Walls and Insulating for the Future
 
Building services group report
Building services group report Building services group report
Building services group report
 
Roof trusses
Roof trussesRoof trusses
Roof trusses
 

Similaire à Module6 module4draftsanitaryandplumbinglayoutanddetails-140806060206-phpapp02

Piping For Cooling Water Circulation between Cooling Tower and Condenser
Piping For Cooling Water Circulation between Cooling Tower and CondenserPiping For Cooling Water Circulation between Cooling Tower and Condenser
Piping For Cooling Water Circulation between Cooling Tower and CondenserIJSRD
 
How to Designate Right Types of Plumbing Pipes.pdf
How to Designate Right Types of Plumbing Pipes.pdfHow to Designate Right Types of Plumbing Pipes.pdf
How to Designate Right Types of Plumbing Pipes.pdfJamil Syed
 
Water supply system (distribution system and house water plumbing)
Water supply system (distribution system and house water plumbing)Water supply system (distribution system and house water plumbing)
Water supply system (distribution system and house water plumbing)Basant Lekhak
 
EP LAB MANUAL
EP LAB MANUALEP LAB MANUAL
EP LAB MANUALSethu Ram
 
Planning and design of building services in multi Story
Planning and design of building services in multi Story Planning and design of building services in multi Story
Planning and design of building services in multi Story Vj NiroSh
 
New Building Service.pdf
New Building Service.pdfNew Building Service.pdf
New Building Service.pdfdaniaalnaji
 
J. PLANS _ SPECS.pptx
J. PLANS _ SPECS.pptxJ. PLANS _ SPECS.pptx
J. PLANS _ SPECS.pptxssuser8eb4e1
 
Unit 5 final
Unit 5 finalUnit 5 final
Unit 5 finaliampichu
 
Pipes, fittings-fixtures and appliance
Pipes, fittings-fixtures and appliancePipes, fittings-fixtures and appliance
Pipes, fittings-fixtures and applianceHarsha Singh
 
Plumbing fittings & fixtures
Plumbing fittings & fixturesPlumbing fittings & fixtures
Plumbing fittings & fixturesJonathanCaporas
 
Plumbing fittings & fixtures
Plumbing fittings & fixturesPlumbing fittings & fixtures
Plumbing fittings & fixturesJonathanCaporas
 
presentation3-161025132139.pdf
presentation3-161025132139.pdfpresentation3-161025132139.pdf
presentation3-161025132139.pdfsakshivaswani2
 

Similaire à Module6 module4draftsanitaryandplumbinglayoutanddetails-140806060206-phpapp02 (20)

Piping For Cooling Water Circulation between Cooling Tower and Condenser
Piping For Cooling Water Circulation between Cooling Tower and CondenserPiping For Cooling Water Circulation between Cooling Tower and Condenser
Piping For Cooling Water Circulation between Cooling Tower and Condenser
 
Liquid Piping Systems
Liquid Piping SystemsLiquid Piping Systems
Liquid Piping Systems
 
How to Designate Right Types of Plumbing Pipes.pdf
How to Designate Right Types of Plumbing Pipes.pdfHow to Designate Right Types of Plumbing Pipes.pdf
How to Designate Right Types of Plumbing Pipes.pdf
 
Water supply system (distribution system and house water plumbing)
Water supply system (distribution system and house water plumbing)Water supply system (distribution system and house water plumbing)
Water supply system (distribution system and house water plumbing)
 
EP LAB MANUAL
EP LAB MANUALEP LAB MANUAL
EP LAB MANUAL
 
Planning and design of building services in multi Story
Planning and design of building services in multi Story Planning and design of building services in multi Story
Planning and design of building services in multi Story
 
New Building Service.pdf
New Building Service.pdfNew Building Service.pdf
New Building Service.pdf
 
J. PLANS _ SPECS.pptx
J. PLANS _ SPECS.pptxJ. PLANS _ SPECS.pptx
J. PLANS _ SPECS.pptx
 
Inst hidrra sanitedificio-tesis
Inst hidrra sanitedificio-tesisInst hidrra sanitedificio-tesis
Inst hidrra sanitedificio-tesis
 
Presentation - energy lose
Presentation - energy losePresentation - energy lose
Presentation - energy lose
 
Unit 5 final
Unit 5 finalUnit 5 final
Unit 5 final
 
Pipes, fittings-fixtures and appliance
Pipes, fittings-fixtures and appliancePipes, fittings-fixtures and appliance
Pipes, fittings-fixtures and appliance
 
Piping design sheets
Piping design sheetsPiping design sheets
Piping design sheets
 
Plumbing fittings & fixtures
Plumbing fittings & fixturesPlumbing fittings & fixtures
Plumbing fittings & fixtures
 
Plumbing fittings & fixtures
Plumbing fittings & fixturesPlumbing fittings & fixtures
Plumbing fittings & fixtures
 
SARA5103.pdf
SARA5103.pdfSARA5103.pdf
SARA5103.pdf
 
Unu gtp-sc-12-36
Unu gtp-sc-12-36Unu gtp-sc-12-36
Unu gtp-sc-12-36
 
6.6 pipes and unions
6.6 pipes and unions6.6 pipes and unions
6.6 pipes and unions
 
presentation3-161025132139.pdf
presentation3-161025132139.pdfpresentation3-161025132139.pdf
presentation3-161025132139.pdf
 
HOUSE DRAINAGE
 HOUSE DRAINAGE HOUSE DRAINAGE
HOUSE DRAINAGE
 

Dernier

The future of UX design support tools - talk Paris March 2024
The future of UX design support tools - talk Paris March 2024The future of UX design support tools - talk Paris March 2024
The future of UX design support tools - talk Paris March 2024Alan Dix
 
WCM Branding Agency | 210519 - Portfolio Review (F&B) -s.pptx
WCM Branding Agency | 210519 - Portfolio Review (F&B) -s.pptxWCM Branding Agency | 210519 - Portfolio Review (F&B) -s.pptx
WCM Branding Agency | 210519 - Portfolio Review (F&B) -s.pptxHasan S
 
Models of Disability - an overview by Marno Retief & Rantoa Letšosa
Models of Disability - an overview by Marno Retief & Rantoa LetšosaModels of Disability - an overview by Marno Retief & Rantoa Letšosa
Models of Disability - an overview by Marno Retief & Rantoa Letšosaannemarleenolthof1
 
Introduce Trauma-Informed Design to Your Organization - CSUN ATC 2024
Introduce Trauma-Informed Design to Your Organization - CSUN ATC 2024Introduce Trauma-Informed Design to Your Organization - CSUN ATC 2024
Introduce Trauma-Informed Design to Your Organization - CSUN ATC 2024Ted Drake
 
Embroidery design from embroidery magazine
Embroidery design from embroidery magazineEmbroidery design from embroidery magazine
Embroidery design from embroidery magazineRivanEleraki
 
Construction Documents Checklist before Construction
Construction Documents Checklist before ConstructionConstruction Documents Checklist before Construction
Construction Documents Checklist before ConstructionResDraft
 
Designing for privacy: 3 essential UX habits for product teams
Designing for privacy: 3 essential UX habits for product teamsDesigning for privacy: 3 essential UX habits for product teams
Designing for privacy: 3 essential UX habits for product teamsBlock Party
 
Create Funeral Invites Online @ feedvu.com
Create Funeral Invites Online @ feedvu.comCreate Funeral Invites Online @ feedvu.com
Create Funeral Invites Online @ feedvu.comjakyjhon00
 
UX Conference on UX Research Trends in 2024
UX Conference on UX Research Trends in 2024UX Conference on UX Research Trends in 2024
UX Conference on UX Research Trends in 2024mikailaoh
 
Math Group 3 Presentation OLOLOLOLILOOLLOLOL
Math Group 3 Presentation OLOLOLOLILOOLLOLOLMath Group 3 Presentation OLOLOLOLILOOLLOLOL
Math Group 3 Presentation OLOLOLOLILOOLLOLOLkenzukiri
 
AMBER GRAIN EMBROIDERY | Growing folklore elements | Barbara Rakovska
AMBER GRAIN EMBROIDERY | Growing folklore elements | Barbara RakovskaAMBER GRAIN EMBROIDERY | Growing folklore elements | Barbara Rakovska
AMBER GRAIN EMBROIDERY | Growing folklore elements | Barbara RakovskaBarusRa
 
Unlocking Conversion_ The Art of Turning Visitors into Loyal Customers.pdf
Unlocking Conversion_ The Art of Turning Visitors into Loyal Customers.pdfUnlocking Conversion_ The Art of Turning Visitors into Loyal Customers.pdf
Unlocking Conversion_ The Art of Turning Visitors into Loyal Customers.pdfIBM
 
Khushi sharma undergraduate portfolio...
Khushi sharma undergraduate portfolio...Khushi sharma undergraduate portfolio...
Khushi sharma undergraduate portfolio...khushisharma298853
 
LRFD Bridge Design Specifications-AASHTO (2014).pdf
LRFD Bridge Design Specifications-AASHTO (2014).pdfLRFD Bridge Design Specifications-AASHTO (2014).pdf
LRFD Bridge Design Specifications-AASHTO (2014).pdfHctorFranciscoSnchez1
 
High-Quality Faux Embroidery Services | Cre8iveSkill
High-Quality Faux Embroidery Services | Cre8iveSkillHigh-Quality Faux Embroidery Services | Cre8iveSkill
High-Quality Faux Embroidery Services | Cre8iveSkillCre8iveskill
 
UI UX Process for SaaS Product Design Success
UI UX Process for SaaS Product Design SuccessUI UX Process for SaaS Product Design Success
UI UX Process for SaaS Product Design SuccessThink 360 Studio
 
How to use Ai for UX UI Design | ChatGPT
How to use Ai for UX UI Design | ChatGPTHow to use Ai for UX UI Design | ChatGPT
How to use Ai for UX UI Design | ChatGPTThink 360 Studio
 
Design mental models for managing large-scale dbt projects. March 21, 2024 in...
Design mental models for managing large-scale dbt projects. March 21, 2024 in...Design mental models for managing large-scale dbt projects. March 21, 2024 in...
Design mental models for managing large-scale dbt projects. March 21, 2024 in...Ed Orozco
 

Dernier (18)

The future of UX design support tools - talk Paris March 2024
The future of UX design support tools - talk Paris March 2024The future of UX design support tools - talk Paris March 2024
The future of UX design support tools - talk Paris March 2024
 
WCM Branding Agency | 210519 - Portfolio Review (F&B) -s.pptx
WCM Branding Agency | 210519 - Portfolio Review (F&B) -s.pptxWCM Branding Agency | 210519 - Portfolio Review (F&B) -s.pptx
WCM Branding Agency | 210519 - Portfolio Review (F&B) -s.pptx
 
Models of Disability - an overview by Marno Retief & Rantoa Letšosa
Models of Disability - an overview by Marno Retief & Rantoa LetšosaModels of Disability - an overview by Marno Retief & Rantoa Letšosa
Models of Disability - an overview by Marno Retief & Rantoa Letšosa
 
Introduce Trauma-Informed Design to Your Organization - CSUN ATC 2024
Introduce Trauma-Informed Design to Your Organization - CSUN ATC 2024Introduce Trauma-Informed Design to Your Organization - CSUN ATC 2024
Introduce Trauma-Informed Design to Your Organization - CSUN ATC 2024
 
Embroidery design from embroidery magazine
Embroidery design from embroidery magazineEmbroidery design from embroidery magazine
Embroidery design from embroidery magazine
 
Construction Documents Checklist before Construction
Construction Documents Checklist before ConstructionConstruction Documents Checklist before Construction
Construction Documents Checklist before Construction
 
Designing for privacy: 3 essential UX habits for product teams
Designing for privacy: 3 essential UX habits for product teamsDesigning for privacy: 3 essential UX habits for product teams
Designing for privacy: 3 essential UX habits for product teams
 
Create Funeral Invites Online @ feedvu.com
Create Funeral Invites Online @ feedvu.comCreate Funeral Invites Online @ feedvu.com
Create Funeral Invites Online @ feedvu.com
 
UX Conference on UX Research Trends in 2024
UX Conference on UX Research Trends in 2024UX Conference on UX Research Trends in 2024
UX Conference on UX Research Trends in 2024
 
Math Group 3 Presentation OLOLOLOLILOOLLOLOL
Math Group 3 Presentation OLOLOLOLILOOLLOLOLMath Group 3 Presentation OLOLOLOLILOOLLOLOL
Math Group 3 Presentation OLOLOLOLILOOLLOLOL
 
AMBER GRAIN EMBROIDERY | Growing folklore elements | Barbara Rakovska
AMBER GRAIN EMBROIDERY | Growing folklore elements | Barbara RakovskaAMBER GRAIN EMBROIDERY | Growing folklore elements | Barbara Rakovska
AMBER GRAIN EMBROIDERY | Growing folklore elements | Barbara Rakovska
 
Unlocking Conversion_ The Art of Turning Visitors into Loyal Customers.pdf
Unlocking Conversion_ The Art of Turning Visitors into Loyal Customers.pdfUnlocking Conversion_ The Art of Turning Visitors into Loyal Customers.pdf
Unlocking Conversion_ The Art of Turning Visitors into Loyal Customers.pdf
 
Khushi sharma undergraduate portfolio...
Khushi sharma undergraduate portfolio...Khushi sharma undergraduate portfolio...
Khushi sharma undergraduate portfolio...
 
LRFD Bridge Design Specifications-AASHTO (2014).pdf
LRFD Bridge Design Specifications-AASHTO (2014).pdfLRFD Bridge Design Specifications-AASHTO (2014).pdf
LRFD Bridge Design Specifications-AASHTO (2014).pdf
 
High-Quality Faux Embroidery Services | Cre8iveSkill
High-Quality Faux Embroidery Services | Cre8iveSkillHigh-Quality Faux Embroidery Services | Cre8iveSkill
High-Quality Faux Embroidery Services | Cre8iveSkill
 
UI UX Process for SaaS Product Design Success
UI UX Process for SaaS Product Design SuccessUI UX Process for SaaS Product Design Success
UI UX Process for SaaS Product Design Success
 
How to use Ai for UX UI Design | ChatGPT
How to use Ai for UX UI Design | ChatGPTHow to use Ai for UX UI Design | ChatGPT
How to use Ai for UX UI Design | ChatGPT
 
Design mental models for managing large-scale dbt projects. March 21, 2024 in...
Design mental models for managing large-scale dbt projects. March 21, 2024 in...Design mental models for managing large-scale dbt projects. March 21, 2024 in...
Design mental models for managing large-scale dbt projects. March 21, 2024 in...
 

Module6 module4draftsanitaryandplumbinglayoutanddetails-140806060206-phpapp02

  • 1. Drafting Sanitary and Plumbing Layout and Details 288 Content Standard Performance Standard The learner demonstrates understanding of concepts and underlying principles in drafting sanitary and plumbing layout and details. The learner independently drafts sanitary and plumbing layout and details following the job requirements. Quarter IV Time Allotment: 16 hrs. MODULE 6 Drafting Sanitary and Plumbing Layout and Details Introduction This module is designed to familiarize students with the concept of sanitary disposal of waste and the principle of introducing clean water in to the residential unit from the source. It will also help the students understand the intricacy of designing and planning a sanitary plumbing and sewerage layout. It also familiarizes them with the different abbreviations and symbols used in drafting of sanitary and plumbing layout, the specification materials used for the construction and the different kinds of fittings intended for a sound construction of the layout. Plumbing drawings are prepared to a very small-scale. Therefore schematic symbols are used for drawing plumbing lines, fixture and other components as they actually appear. These symbols are used to show the type and location of fixtures, valves, joints and other plumbing devices. Objectives: At the end of this module, you are expected to:  draft water distribution system; and  draft sanitary and storm drainage
  • 2. Drafting Sanitary and Plumbing Layout and Details 289 At this point, you are heading into meaningful activities and learning encounters. Complete the exercises and answer the suggested worksheets to experience lifelong, practical learning that awaits at the end of this module. ENJOY YOUR JOURNEY! ***** Pre-assessment: Multiple Choice Direction: Choose the letter of the correct answer. Write your answer in the space provided before each number. _____1. A kind of fitting used to straight section pipes. a. elbows b. coupling c. cross d. tee _____2. How is hot and cold water distributed from the source to the different parts of the building? a. by pressurizing the source c. by mixing hot and cold water b. by raising water temperature d. by chemical means _____3. Used to close systems and to connect pipes that have to be disassembled occasionally. a. unions b. plug valve c. nipples d. reducers _____4. The preceding plumbing symbol indicates a -- a. coupling c. straight cross b. safety valve d. gate valve _____5. A fitting used to change direction of a pipe line either 90 degrees or 45 degrees. a. T b. cross c. elbows d. couplings _____6. Used to close the end of a pipe. a. cap b. plug c. bushing d. unions _____7. The storm drainage is considered a part of the – a. plumbing system. c. foundation system. b. electrical system. d. elevation system. _____8. Used to close an opening in a fitting. a. cap b. plug c. bushing d. unions _____9. Which of these common plumbing symbols/abbreviations indicate a
  • 3. Drafting Sanitary and Plumbing Layout and Details 290 junction box? a. JXB b. JBox c. JB b. JBX _____10. The ideal or suggested size in constructing the septic tank with a 15 number of people is______. a. depth- 1:20, W-1:0, L- 2:0 c. depth 1:50 , W- 1:20, L-1:50 b. depth- 1:50, W-1:5, L-150 d. depth 2:50, W-1:50, L -2:50 _____11. Used to reduce the size of an opening. a. bushing b. unions c. cap d. plug _____12. A network of pipes and fittings that carry off wastes and each plumbing fixture is titled with the appropriate pipe and fitting. a. Sanitary installation c. Drainage system b. Polyvinyl pipe and fittings d. Sanitary and storm drainage _____13. Used to close systems and to connect pipes that are to be disassembled occasionally. a. cap b. plug c. bushing d. unions _____14. A water distribution system shown in an elevation, on plan and on isometric using the different symbols. a. isometric draft c. isometric water system b. water system diagram d. schematic drawing _____15. Which is NOT a type of valve: a. Gate valve c. Check valve b. Globe valve d. Metal valve Skills Evaluation Direction: Listed below are some of the most important skills that you must gain in order to draft a quality floor plan. On the right side of the matrix lists the skills expected of you to master. Rate yourself by checking “Not much”, if you are not so familiar yet, “A little” and/or “A lot”, if you are already familiar with the skills. Don’t feel bad if you checked “Not Much” in all of the skills. Keep in mind that this is being administered to determine your pre-entry knowledge of and skills on the lesson to be presented. Skills in drafting water distribution system Not Much A little A lot  I can draft hot and cold water distribution systems according to Plumbing and Water Codes  I can indicate signs and symbols according to sanitary and plumbing requirements
  • 4. Drafting Sanitary and Plumbing Layout and Details 291 Learning Goals and Targets: After reading the introduction and carefully answering the pre assessment instrument, you might have ideas of what you will be dealing with in this module. Now prepare to set your goals and targets for this module by completing the activity below. Write your answer in your notebook. My goals are: My targets are: Goal 4 Goal 3 Goal 2 Goal 1 Target 1 Target 2 Target 3
  • 5. Drafting Sanitary and Plumbing Layout and Details 292 Lesson 1: Draft Water Distribution Systems This lesson is designed to familiarize you to draft the proper distribution of water system (hot and cold water) and the signs and symbols used which are based on the standard water code of the Philippines. Operational Definition of Terms: Aluminum is a lightweight but relatively strong metal often alloyed with copper to increase hardness and strength. Gate Valve is usually chosen for locations where it is left completely open most of the time because it offers the least resistance to the flow of water. Diagrammatic Layout is used for drafting layout in architectural plans. Nipples are short pieces of pipes threaded on both ends. Plumbing refers to the water supply and drainage of wastewater sewage. Plumbing system refers to the supply pipes that carry fresh waste water under pressure from a public water supply or individual wells to fixtures. Reducer is used to connect straight section pipes of different sizes. Scale Layout is used for drafting large pipes. Overview One of man’s essential needs is water. He could live for days without food but not without water. Water appears in its natural state (liquid) or solid (ice) and gas (vapor) or steam. It is 830 times heavier than air but is 133 times lighter in its gaseous state. This can be sourced from: rain water, natural surface water and underground water. Water is a necessity. It is conveyed from the source to the household through a system of pipes. Water distribution systems for residential and commercial buildings are conveyed thru pipes, a PVC, Cast Iron or G.I. pipe. Hot and cold water is supplied to the buildings by a series of pipes connected from the source under pressure to the building fixtures thru a water line distribution system. Know
  • 6. Drafting Sanitary and Plumbing Layout and Details 293 Pipes used for water line distribution systems may be classified as: 1. Steel and wrought iron pipe 2. Cast iron pipe 3. Seamless brass and copper pipe 4. Copper tubing 5. Special pipes such as PVC (Polyvinyl Chloride), Aluminum and Stainless Steel pipes, and CPV’C (Chlorinated Polyvinyl Chloride) pipe Water main refers to the public sewer system along the streets, or laid underground where the service to the house is connected. Water coming from it is under pressure but normally could serve only houses of moderate height. A pump is installed to augment the pressure that forces the water to move inside the pipe. The size of the service pipe is determined by the demand for water. A maximum demand is one factor, or the maximum water discharge for plumbing fixtures and the probable demand is another, which is the peak demand or peak load. Connection of Pipes Pipes are connected by methods dependent upon the material and the demands of service. Steel, brass or bronze pipes are normally threaded and screwed into coupling and fitting. Fittings are used to join adjacent lengths of pipes and to provide changes of direction, and branch connections at any angle and to effect a change in size. Connections 1. Threaded connections 2. Soldered fittings 3. Connection by bolded flanges 4. Solvent cement weld connections Common types of fittings 1. Screwed fittings 2. Welded joints 3. Flanged joints 4. Solder joints 5. Slip fittings (for plastic pipes) Valves 1. Gate valves 2. Globe valves 3. Check valves
  • 7. Drafting Sanitary and Plumbing Layout and Details 294 4. Pressure reducing valves 5. Safety valves Valves are specified by giving the nominal size, material and ride. Kinds of Fittings 1. Elbows are used to change direction of a pipeline either 90 degrees or 45 degrees. 2. Tee connects three pipes. 3. Cross connects four pipes. 4. Couplings are used to connect straight section pipes. 5. Reducers are used to connect straight section pipes of different sizes. 6. Nipples are short pieces of pipes threaded on both ends and classified as close nipple and short nipple. 7. Cap is used to close the end of a pipe. 8. Plug is used to close an opening in a fitting. 9. Bushing is used to reduce the size of an opening. 10. Unions are used to close systems and to connect pipes that are to be disassembled occasionally. Systems of Drawing Pipe Layout 1. Scale Layout are used for large pipes 2. Diagrammatic lay out are used for architectural plans.
  • 8. Drafting Sanitary and Plumbing Layout and Details 295
  • 9. Drafting Sanitary and Plumbing Layout and Details 296 Suggested Activity 1 Directions: Read each item carefully. Identify the correct answer and write it on a separate sheet of paper. __________ 1. It is used to stop or regulate the flow of fluids. __________ 2. It is used to limit the flow of fluids to one direction only. __________ 3. It is used to connect three pipes. __________ 4. It is used to connect straight section pipes of different sizes. __________ 5. They are short pieces of pipes threaded at both ends. __________ 6. They are full sized straightway openings that offer small resistance to the flow of fluids. __________ 7. It is used to join adjacent length of pipes. __________ 8. It is used to close the end of a pipe. __________ 9. It is used to close an opening or fitting. __________ 10. It is a kind of layout for pipes used in architectural plans. Group Activity: Identification of pipe fittings and pipe materials Directions: Note: The teacher shall distribute pictures of plumbing fixtures and fittings.  Work in groups of 3 to 5 (depending upon the number of students in the class) and chose a leader.  Identify the different kinds of: Process
  • 10. Drafting Sanitary and Plumbing Layout and Details 297 o pipes used in plumbing; o materials used; and o different kinds of pipes fittings and flanges.  Write a description in a piece of paper, each of the above in terms of its characteristics and uses.  Report your outputs to your teacher to assess and/or check your learning of the targeted knowledge and skills. The plumbing system is important to the designer or draftsman. Although plumbing plans may be omitted on small residential dwellings, they are always included in larger projects for small residences; the plumbing layout is left to the contractor or the owner to decide. A plumbing system performs two major functions which are: 1. For Water Distribution 2. Sewage Disposal Water distribution systems, whether hot or cold, are distributed by pipes from the source to the house. Amenities as discussed earlier, when tracing the path of the supply of water and fixtures fittings, the architectural designer uses symbols to indicate the distribution system and the different fixtures. The water distribution system is shown in an elevation, on plan and on isometric using the different symbols, hence this is called a schematic drawing. In drawing the layout, here are the common symbols used for cold water line and sanitary layout. Know COMMON PLUMBING SYMBOLS
  • 11. Drafting Sanitary and Plumbing Layout and Details 298 Like most architectural drawings, plumbing drawings are drawn to a small scale. It would be unrealistic to draw all fixtures and lines on the drawing paper. Therefore schematic symbols are used for various plumbing fixtures and lines. They are used to show the type and location of fixtures, joints values and other devices. The difference in appearance of an orthographic drawing of fixtures and other devices with that of a schematic drawing is shown in the figure. SANITARY & PLUMBING SYMBOLS LEGEND/ABBREVIATION Water Closet WC Vent at Ceiling VAC Vent Stack thru Roof VSTR Cold Water Line CWL Hot Water Line HWL Concrete Drain Pipe CDP Cast Iron Soil Pipe CISP Down Spout DS Cast Iron Vent Stack CISS Cast Iron Vent Stack CIVS Vent At Ceiling VAC Vent Stack Thru Roof VSTR Catch Basin CB Junction Box JB Water Meter WM Galvanize Iron Pipe Water Line GIPWL Cold Water Riser CWR Cold Water Down Feed CWDF Fire Line FL Deck Drain DD Canopy Drain CD Sprinkle Riser SPR Dry Stand Pipe Riser DSPR Fire Hose Cabinet FHC Lavatory LAV Water Closet WC Floor Drain FD Clean Out CO
  • 12. Drafting Sanitary and Plumbing Layout and Details 299
  • 13. Drafting Sanitary and Plumbing Layout and Details 300
  • 14. Drafting Sanitary and Plumbing Layout and Details 301 SYMBOL ELEVATION PICTORIAL Double Brach Elbow – DBL EL Straight Cross - STX Safety valve – SFTY V Gate Valve – GT V Hand Valve – HND V Pipe Outlet Up - P Pipe Outlet Down - P Coupling - CPLG Elbow 90° - EL Elbow 45° - EL Tee 90° - T Lateral 90° - LAT Clean Out - CO Reducer - RED
  • 15. Drafting Sanitary and Plumbing Layout and Details 302 SYMBOL ELEVATION PICTORIAL Flanged Fittings – FL FT Screwed Fittings – SC FT Bell and Spigot Fittings – BL/SP FT Welded Fitting – WLD FT Soldered Fitting – SLD FT Expansion Joint – EXP JT Motor Operated Vehicle – MOP V Meter – M Floor Drain - FD Cess Pool – CP Dry Well - DW Septic Tank – SEP TNK SEPTIC – TANK Distribution Box – SEP TANK DIS BX SUMP PIT - SP
  • 16. Drafting Sanitary and Plumbing Layout and Details 303 Suggested Activity 2 A. Draw the symbols for the following terms on a separate sheet of paper. 1. Faucet 6. Hose bib 2. Water closet 7. Lavatory 3. Gate valve 8. Water meter 4. Shower 9. Kitchen sink 5. Floor drain 10. Clean out B. Classification: Given the word pool below, try to find where each of these word belongs. PIPES PIPE CHECK FITINGS VALLES C. Draft a water line layout for a Toilet and Bath Procedure: 1. From the given plan of a T&B, indicate the location of bathroom fixtures by drawing the symbols of each on the place where they think is the best location. Process FLARED TEE SAFETY ELBOW CAP GATE REDUCER FERRULE BUSHING CROSS
  • 17. Drafting Sanitary and Plumbing Layout and Details 304 2. In as much as the kitchen is adjacent to the toilet and bath, naturally the source of water supply comes from the same direction. Try to draw the layout of the water supply line to the different fixtures they have identified. Try to draw the water supply line to indicate the pipe fittings used and the different fixtures and the water flow. 3. After highlighting the pipe fittings used and indicated the water supply source and its flow, darken the supply line and indicate the pipe and fixture specifications by writing them beside the fixtures as indicated by the arrow. Then, write down the legend for identification.
  • 18. Drafting Sanitary and Plumbing Layout and Details 305 A typical diagram of the plumbing system of a single detached one-storey dwelling units. The Water Line Layout The water distribution system is the network of pipes and fittings for conveying water to the plumbing fixtures while the system of pipes and fittings for carrying off wastes is referred to as sanitary installation The building water entrance pipe is connected to the street by means of a corporation cock, if the water is supplied by the community. The amount of water passing thru the water service is measured by the water meter. If water service is supplied thru a deep well, a water meter is not necessary. From this, the water pipes branch out to the fixtures inside the residential unit requiring water. Clean water lines are represented on a plan by a visible line and two dashes, while sanitary lines are represented by a bold continuous line. The fixtures are indicated by their common symbols. Storm drainage lines are drawn with two invisible lines that run parallel to each other. While vent pipes are bold hidden lines. The operation of the basic plumbing system is readily understood through the diagram shown here. To get water to a structure for use by the tenants and to remove sewage and unwanted water is the purpose of a plumbing system.
  • 19. Drafting Sanitary and Plumbing Layout and Details 306 A Sample Plumbing Layout A Typical Plumbing System
  • 20. Drafting Sanitary and Plumbing Layout and Details 307
  • 21. Drafting Sanitary and Plumbing Layout and Details 308 Water Pipes and Fittings Required For Installing Commonly Used Plumbing Fixtures
  • 22. Drafting Sanitary and Plumbing Layout and Details 309 A typical installation of a water distribution using PVC pipes with G.I. Pipes for in-house is done with PVC pipes adapter fittings. To obtain watertight joints, solvent cement is applied. uPVC Adafter Fitting for uPVC-to-Galvanized Iron Water Piping Connectors
  • 23. Drafting Sanitary and Plumbing Layout and Details 310 Shown below are the procedure on how to lay-out the plumbing system in the floor plan. Procedure: 1. From the plan shown below, indicate the location of water fixtures by drawing their symbols on the place you think is the most suitable location for each. You too, shall indicate the water supply source from the street water branch. ReflectandUnderstand
  • 24. Drafting Sanitary and Plumbing Layout and Details 311 2. After locating and indicating the location of the fixtures, draw the water line connection from the water source. In addition, try to indicate the position of the water meter and the check valve based on their layout and the source of water supply. 3. Draw the water line layout of the pipe fittings and the fixtures to show the different kinds of fittings use, and write down the specifications of the material used. BEDROOM BEDROOM DINE/KIT KS LIVING
  • 25. Drafting Sanitary and Plumbing Layout and Details 312 4. After indicating and writing down the material used for the pipe and fittings, 5. Darken the water layout and write down the abbreviations on the fixtures together with the legend to distinguish the different water fixtures. LEGEND F Faucet GV Gate Valve HB Hose Bibb WM Water Meter WC Water Closet SHO Shower Head LAV Lavatory GIP Galvanized Iron Pipe
  • 26. Drafting Sanitary and Plumbing Layout and Details 313 Directions: From the plan shown below, sketch a clean water line layout. Specific Requirements: 1 faucet 1 shower head 1 lavatory 1 water closet Transfer
  • 27. Drafting Sanitary and Plumbing Layout and Details 314 Procedure: 1. From the preceding water line layout, determine which axis is to be used to present the diagram 2. Indicate the height of water fixtures according to scale ratio used and based on accepted architectural standards. Transfer
  • 28. Drafting Sanitary and Plumbing Layout and Details 315 3. Layout water distribution system and indicate location of fittings fixtures. 4. Finalize drawing and draw legend
  • 29. Drafting Sanitary and Plumbing Layout and Details 316 Summative Test Directions: From the plumbing layout drawn, draft the isometric plumbing diagram. Use standard height. Transfer
  • 30. Drafting Sanitary and Plumbing Layout and Details 317 Lesson 2. Draft Sanitary and Storm Drainage The sanitary installation is referred to as the network of pipes and fittings that carry off wastes and each plumbing fixture is titled with the appropriate pipe and fitting. The discharges are conveyed to the septic vault. The storm drainage system, on the other hand, consists of pipes, fittings, catch basins, area drain and is intended for getting rid of water from the building roof and its surrounding and is conveyed to the street sewer. The storm drainage is considered part of the plumbing system. The pipe used for sanitary and storm drainage most common to homeowners and contractors are the plastic pipe or Polyvinylchloride (PVC) pipes and the concrete pipe for area drain. Skills Evaluation Direction: Listed below are some of the most important skills that you must gain in order to draft a quality floor plan. On the right side of the matrix lists the skills expected of you to master. Rate yourself by checking “Not much”, if you are not so familiar yet, “A little” and/or “A lot”, if you are already familiar with the skills. Don’t feel bad if you checked “Not Much” in all of the skills. Keep in mind that this is being administered to determine your pre-entry knowledge of and skills on the lesson to be presented. Skills in drafting sanitary and storm drainage Not Much A little A lot  I can draw sewerage plan layout according to Plumbing Code  I can draft storm drainage plan according to Plumbing Code  I can draw details and symbols according to sanitary and plumbing requirements Learning Goals and Targets: After reading the introduction and carefully answering the instrument, you might have ideas of what you will be dealing with in this module. Now prepare to set your goals and targets for this module by completing the activity below. Write your answer in your notebook. Know
  • 31. Drafting Sanitary and Plumbing Layout and Details 318 My goals are: My targets are: Overview Wastewater is discharged by gravity through the disposal system. All pipes in this system therefore must slant in a downward direction so the weight of the waste will cause it to move down. Because of this gravity flow, waste lines are larger than water lines. The stacks are the vertical lines while the branches are the horizontal lines. Vents are also provided for air circulation and to permit sewer gases to escape thru the roof. This equalizes the air pressure in the drainage system. The wastewater flows starting at the fixture trap, which is provided to stop gases from entering the building and each fixture has a separate trap or seal to prevent backflow of sewer gas, through the fixture branches to the main sewer line. Waste stacks carry only wastewater while solid wastes runs thru the soil lines, which are the largest in the system and are flushed with water after each use. Goal 4 Goal 3 Goal 2 Goal 1 Target 1 Target 2 Target 3
  • 32. Drafting Sanitary and Plumbing Layout and Details 319 Piping systems are vital to modern society. Some systems may be complex; others may be simple such as in a residential dwelling unit. But they share some common elements, whether they are steel, plastic, copper pipes or tubing. Sanitary and storm drainage for residential dwelling are either wrought – iron pipes, Polyvinylchloride (PVC) pipes and for drainage is either concrete pipe or PVC pipe. The more common today is the unplasticized Polyvinylchloride (uPVC) pipe. Polyvinyl pipe and fittings are available in commercial length of 3.0 meters and also available in schedule 40 and 80. They are usually assembled with slip joint fittings and solvent, both PVC and chlorinated Polyvinylchloride (cPVC) pipes are commonly available in sizes ranging from ½’ to 4” inside diameter. The Sewage Disposal System Absence of a good sewage disposal system can result to contamination of water and water-borne diseases. It is important to value a good disposal system. There are different types of sewage disposal system, from the old to the more scientific ones: 1. Cesspool 2. Privy 3. Septic Tank 4. Public Sewer line The sanitary system is of two types: the intercepting and the tributary or contributing sewer. The intercepting type is constructed with concrete pipes while the tributary sewer is laid in an open trench and is made of vitrified clay or bricks. Water Lines Plumbing Elevation
  • 33. Drafting Sanitary and Plumbing Layout and Details 320
  • 34. Drafting Sanitary and Plumbing Layout and Details 321
  • 35. Drafting Sanitary and Plumbing Layout and Details 322 The Septic Tank The septic system converts solid wastes into liquid by bacterial action, the wastes flow into a septic tank some distance away from the house. The liquid waste flows thru to the sewer line while the sludge remains at the digestion chamber of the tank. The septic tank is constructed with reinforced concrete, and it should be located at a safe distance from the source of potable water, and it should also be airtight. The size and type of the system varies according to the number of people served, the contour and soil type. Inlet Outlet Inlet
  • 36. Drafting Sanitary and Plumbing Layout and Details 323 Types of Sanitary Fittings used in plumbing System of Septic Vaults SANITARY FITTING
  • 37. Drafting Sanitary and Plumbing Layout and Details 324 The Size of the Septic Tank The septic tank should be constructed as to have enough room for accumulated sludge. Here are some of the suggested sizes. NUMBERS OF PERSONS SERVED INSIDE DIMENSION OF DIGESTION CHAMBER D- DEPTH W- WIDTH L - LENGTH METERS METERS METERS 10 1.20 0.90 1.30 15 1.20 1.00 2.20 20 1.20 1.25 2.50 25 1.20 1.40 2.80 30 1.30 1.50 3.00 35 1.30 1.60 3.20 40 1.40 1.65 3.30 45 1.40 1.75 3.50 50 1.50 1.80 3.60 55 1.50 1.85 3.90 70 1.50 2.00 4.00 80 1.60 2.20 4.40 90 1.80 2.30 4.50 100 1.80 2.50 5.00 Sizes of Septic Vault The Typical Detail of a Septic Tank
  • 38. Drafting Sanitary and Plumbing Layout and Details 325 A. Direction: Write down the abbreviations of the following terms on a separate sheet of paper. Terminologies: 1. Concrete pipe 2. Catch basin 3. Area drain 4. Septic vault 5. Galvanized iron pipe 6. Wrought iron pipe 7. Vent stack thru roof 8. Polyvinyl chloride 9. Chlorinated polyvinyl chloride 10. Outside diameter B. Draft Household Sanitary Layout: 1. With the given floor plan, you are supposed to draw the sanitary layout for this housing unit. Indicate first where you would locate your septic vault outside the building. Process
  • 39. Drafting Sanitary and Plumbing Layout and Details 326 2. After locating the place where you would construct your septic vault, draw and indicate the location of the different storm drainage fixtures. 3. Indicate the location of the different sanitary fixtures by drawing their symbols on the area where they are best located. Then draw the layout, connecting all these fixtures and to the septic vault with the sewer line connecting to the street sewer.
  • 40. Drafting Sanitary and Plumbing Layout and Details 327 4. After drawing the layout, indicate the different pipes and fittings used by drawing their symbols on the sewer line layout and write down also the material specification for the fixtures used.
  • 41. Drafting Sanitary and Plumbing Layout and Details 328 The Drainage System The drainage system is sometimes referred to as the DWV or the drainage, the waste and the vent system. The construction and installation of this must conform to the provisions of the building and plumbing codes. Some of the general requirements are as follows: 1. Pipes must be fitted and tightly connected to avoid leakage. 2. Ventilation must convey gases to the atmosphere. 3. Each fixture must be provided with a suitable trap to prevent backflow or gases. 4. The fixture must be re-vented to avoid siphoning of the water seal. 5. Drainage pipes should be sloped or graded properly. 6. Drainage pipes should be provided with adequate clean out for maintenance purposes. The waste pipe which receives the discharge of any fixture except water should be installed at 2% or 20mm slope per meter run. The size of the waste pipe is to be considered in the installation as this pipe serves fixture discharges. And when the pipe must be opened in case of trouble, a clean-out should also be installed and must be accessible to the plumber. Slope or Pitch The soil pipe receives and conveys drainage of water closets and other fixtures to the house drain. It should be properly concealed or embedded and should be placed in a manner that the branches should be as short as possible. As a rule, it should extend and terminate through the roof of the building. Know
  • 42. Drafting Sanitary and Plumbing Layout and Details 329 Second Floor First Floor The House Drain The sanitary drain only receives discharges of sanitary and domestic wastes only while the storm drain receives storm, clear water or surface water wastes.
  • 43. Drafting Sanitary and Plumbing Layout and Details 330 A typical house drain is shown below. The House Sewer The portion of the horizontal drainage system starts from the outer surface of the dwelling and terminates at the public sewer. A minimum size of 150mm (6”Ø) is used for residential dwellings.
  • 44. Drafting Sanitary and Plumbing Layout and Details 331 The Storm Drain It is the part of the plumbing system which conveys rain or storm water into the street gutter. It is of two types: the inside storm drain and the outside storm drain. Layout of the two is shown in the following illustrations.
  • 45. Drafting Sanitary and Plumbing Layout and Details 332 A Typical Catch Basin Detail The Catch Basin The catch basin water discharges from the roof and conveys it to the storm drainage line. It is more or less of the same use as the area drain. It also serves as a manhole for cleaning.
  • 46. Drafting Sanitary and Plumbing Layout and Details 333 Directions: From the plan shown below, sketch the sewer line from the fixtures to the street sewer. Label the drawing. Requirements: 1 – Kitchen Sink 1 – Water Closet 1 – Floor Drain 1 – Septic Vault 1 – Lavatory ReflectandUnderstand
  • 47. Drafting Sanitary and Plumbing Layout and Details 334 Summative Test Directions: From the layout you drafted. Draw a sanitary and plumbing layout and details following the job requirement. Use approved standard height of amenities. Note: You are provided with a copy of the plan. Requirements: 1- Kitchen Sink 1- Water Closet 1- Floor Drain 1- Septic Vault Transfer
  • 48. 335 I. Enrichment Activity: Draft a septic vault for 5 – 7 persons Procedure: 1. Refer from the table on recommended sizes of septic vaults. See if the number of persons in the household fits in the data for recommended size of vault. 2. Take down the measurements: width, height and length. Transfer such measurement on your drawing paper. 3. Draw the outline of the septic vault with your pencil using light guidelines only. As you draw the outline, draw also the thickness of the sides of the septic vault, taking into consideration the thickness of CHB used for walls partitions. 4. Indicate also the location of the manhole and the manhole cover. After drawing the outline re-checked your measurements, write down your dimensions and you are ready to draw the reinforcing bars. You may draw your rebars covering the whole area of the vault or you can have a portion of it only.
  • 49. 336 5. Draw the vertical and horizontal bars for the reinforcement of the septic vault. The standard distances and size of the rebars are 12mm Ø for vertical bars and 10mmØ for horizontal bars. For the slabs on top of it would be 10mm Ø spaced at 20cm on both ways of the slab. 6. Draw only the portion you wish to show the detail of the reinforcements. Indicate now the inlet valve, in the digestion chamber its position or location and its size, together with the outlet valve. 7. From the plan you have already drawn, project dimensions downward and draw a longitudinal section of your septic vault. Remember the thickness and measurements of the plan should be the same as your section.
  • 50. 337 8. With the data on its depth you have gathered, layout the depth of the septic vault, including its foundation and footing. Indicate the location of your inlet and outlet valves which should have a distance from the bottom of the slab of about 30 cm. for the air space and the water level. 9. Draw vertical and horizontal bars on the sides and on the footing. 10.Review the drawing, its dimensions and measurements. Finalize the drawing by darkening the lines with a technical pen. Write down the material specifications and construction notes. CROSS
  • 51. 338 II. Drafting Sanitary and Plumbing Layout and Details Directions: Draft a catch basin detail with the following requirements: 1. Indicate the size of catch basin according to structural and design standard. 2. Draft outlines of both plan and sectional elevation. 3. Draft outlines of pipes and slope of pipes 4. Darken lines or ink drawing .draft dimensions and specifications.
  • 52. 339 Post-Assessment Answer the post assessment below to determine whether there is significant increase in your understanding of the lesson on drafting water distribution, sanitary and storm drainage systems. The feedback to this post assessment is appended on page ____ Good Luck! Direction: Choose the letter of the correct answer. Write your answer in the space provided to each number. _____1. A kind of fitting used to straight section pipes. a. elbows b. coupling c. cross d. tee _____2. How is hot and cold water distributed from the source to different parts of the building? a. by pressurizing the source c. by mixing hot and cold water b. by raising water temperature d. by chemical means _____3. Used to close systems and to connect pipes that have to be disassembled occasionally. a. unions b. plug valve c. nipples d. reducers _____4. The preceding plumbing symbol indicates a -- a. coupling. c. straight cross b. safety valve. d. gate valve. _____5. A fitting used to change direction of a pipe line either 90 degrees or 45 degrees. a. T b. cross c. elbows d. couplings _____6. Used to close the end of a pipe. a. cap b. plug c. bushing d. unions _____7. The storm drainage is considered a part of the – a. plumbing system. c. foundation system. b. electrical system. d. elevation system.
  • 53. 340 _____8. Used to close an opening in a fitting. a. cap b. plug c. bushing d. unions _____9. Which of these common plumbing symbols/abbreviations indicate a junction box? a. JXB b. JBox c. JB d. JBX _____10. The ideal or suggested size in constructing the septic tank with a 15 number of people is______. a. depth- 1:20, W-1:0, L- 2:0 c. depth 1:50 , W- 1:20, L-1:50 b. depth- 1:50, W-1:5, L-150 d. depth 2:50, W-1:50, L -2:50 _____11. Used to reduce the size of an opening. a. bushing b. unions c. cap d. plug _____12. A network of pipes and fittings that carry off wastes and each plumbing fixture is titled with the appropriate pipe and fitting. a. Sanitary installation c. Drainage system b. Polyvinyl pipe and fittings d. Sanitary and storm drainage _____13. Used to close systems and to connect pipes that are to be disassembled occasionally. a. cap b. plug c. bushing d. unions _____14. A water distribution system shown in an elevation, on plan and on isometric using the different symbols is called _________. a. isometric draft d. isometric water system b. water system diagram c. schematic drawing _____15. Which is NOT a type of valve: a. Gate valve c. Check valve b. Globe valve d. Metal valve