Conductor : Annealed Tinned Copper Conductor
(opt : plain) according to IEC 60228, Class 5
Insulation : Elastomeric Compound
Type EI 2 (Silicon Rubber)
by Rohit Damodaran
Application Product Construction Technical Data Siechem Single Core, ATC Conductor, Silicone Insulated Unsheathed H05S-K Type Cable by Rohit Damodaran
Similaire à Application Product Construction Technical Data Siechem Single Core, ATC Conductor, Silicone Insulated Unsheathed H05S-K Type Cable by Rohit Damodaran
Similaire à Application Product Construction Technical Data Siechem Single Core, ATC Conductor, Silicone Insulated Unsheathed H05S-K Type Cable by Rohit Damodaran(20)
Application Product Construction Technical Data Siechem Single Core, ATC Conductor, Silicone Insulated Unsheathed H05S-K Type Cable by Rohit Damodaran
1. Application Product Construction Technical Data
Siechem Single Core, ATC Conductor, Silicone Insulated Unsheathed H05S-K Type Cable
Nominal
Cross Section
2
(mm )
Part Number
Cable Weight
(Kg/Km) approx.
ü Specification : BS EN 50525-2-41
2 2
(I) 0.5 mm to 2.5 mm - Class 5
2 2
(ii) 4 mm to 240 mm - Class 5
(generally as per BS EN 50525-2-41)
ü Test voltage : 2000 V
ü Operating Temperature : -55°C to +180°C
ü Rated Voltage : 300/500V
ü Max. Temperature of Short Circuit : 350° C
ü Min. Insulation Resistance constant at 27°C : 3670 M Ω. km
2D View
Note : XX* : Please add last two digits in the part number as per the colour code given hereunder replacing XX while ordering.
Red - 01 Yellow - 02 Blue - 03 Black - 04 Green - 05 Yellow-Green - 06 Grey - 07 Brown - 08 White - 09 Orange - 10 Violet - 11
Chocolate - 12 Tan - 13 Charcoal - 14 LT Blue - 15 DK Grey - 16 LT Green - 17 DK Green - 18 DK Blue - 19 Purple - 20 Pink - 21
Catalogue
No.
A063
www.siechem.com
* 16 X 0.20
24 X 0.20
32 X 0.20
30 X 0.25
50 X 0.25
56 X 0.30
84 X 0.30
80 X 0.40
126 X 0.40
196 X 0.40
276 X 0.40
396 X 0.40
360 X 0.50
475 X 0.50
608 X 0.50
756 X 0.50
925 X 0.50
1221 X0.50
Insulation thickness
( Nom.)(mm)
0.5
0.75
1
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
Conductor Construction
No.of Strands x Strand dia
Nos x mm (Nom.)
40.1
26.7
20.0
13.7
8.21
5.09
3.39
1.95
1.24
0.795
0.565
0.393
0.277
0.210
0.164
0.132
0.108
0.0817
ü Conductor : Annealed Tinned Copper Conductor
(opt : plain) according to IEC 60228, Class 5
ü Insulation : Elastomeric Compound
Type EI 2 (Silicon Rubber)
ü Colour : Black (or) as per customer order
Overall
diameter
Nom.(mm)
ü For wiring at high ambient temperature
zones like boiler house, etc.
ü Electric motor industry.
ü Air- Conditioning technology.
ü Furnace construction.
ü Thermal and heating elements.
10
13
15
21
32
48
65
106
160
246
332
468
637
856
1080
1333
1639
2112
Features
ü High temperature - resistant.
ü Halogen - free.
ü Cold resistant.
ü Flame retardant.
ü Weather resistant.
Max Conductor
Resistance
0
at 20 C Ω/km
Wires & Cables
Wires & Cables
Siechem Single Core, ATC Conductor, Silicone Insulated Unsheathed Cable
H05S-K Type
0.8
0.8
0.8
0.9
1.0
1.1
1.1
1.2
1.2
1.4
1.4
1.6
1.6
1.8
1.8
2.0
2.2
2.4
2.7
2.9
3.2
3.5
4.2
4.9
5.4
6.7
7.6
9.3
10.6
12.4
14.2
16.0
17.8
19.8
21.9
24.8
A06306XX
A06308XX
A06310XX
A06313XX
A06316XX
A06319XX
A06323XX
A06327XX
A06328XX
A06330XX
A06332XX
A06334XX
A06337XX
A06338XX
A06341XX
A06342XX
A06344XX
A06346XX
13
All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and
Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction.
OHSAS
18001
AS
9100
AS
45001
ISO
9001
ISO