Mitsubishi ,
Catalog Thiết Bị Điện Mitsubishi , Catalog Thiết Bị Điện
Catalog Phụ Kiện Mitsubishi , Catalog Phụ Kiện,
Catalog Mitsubishi , Catalog,
https://www.dienhathe.com,
Chi tiết các sản phẩm khác của Mitsubishi tại https://dienhathe.com
Xem thêm các Catalog khác của Mitsubishi tại https://dienhathe.info
Để nhận báo giá sản phẩm Mitsubishi vui lòng gọi: 0907.764.966
Double Revolving field theory-how the rotor develops torque
Mitsubishi graphic operation terminal got2000 series ethernet communication unit
1. FACTORY AUTOMATIONNov. 2016
● Design safe and secure network configuration
● Prevent unauthorized access with two physically
separate networks
● Reduce the overall communication load in the network
● Enable visualization at production site
Discover new possibilities with two Ethernet ports
Ethernet communication unit
GOT2000 Series
2. Discover new possibilities with two Ethernet ports
1) Design safe and secure network configuration
The information system network in the office is separated from control system network at the production site;
therefore the network architecture is safer and more secure. If a network error occurs in the office by a faulty network
device, production site is not affected.
Personal computer
IP: 192.168.3.1
Personal computer
IP: 192.168.3.2
Ethernet
Ethernet interface
(built-in)
IP: 192.168.3.18
Ethernet
communication unit
(option)
IP: 192.168.5.22
Ethernet
Programmable controller
IP: 192.168.5.1
Programmable controller
IP: 192.168.5.2
Personal computer
IP: 192.168.5.3
Information system
network
(office)
Control system
network
(production site)
Error!Error!
Communication
continues
!
Communication
continues
2) Prevent unauthorized access with two physically
separate networks
Access to the devices in the control system network is not allowed via GOT
from the personal computer in the information system network*. Therefore,
even in the unusual event of unauthorized access to the information system
network, you can reduce the risk of illegal copy or alteration of the data in the
control system network.
* Access is allowed from the engineering software (MELSOFT GX Works3, etc.) using the FA transparent
function (to be supported soon) and from GT SoftGOT using the SoftGOT-GOT link function. When
using the FA transparent function and the SoftGOT-GOT link function, it is recommended to use
them with the IP filter function or set passwords to various project data to enhance security.
Information system
network
(office)
Control system
network
(production site)
Personal computer
IP: 192.168.3.1
Access allowed between
personal computer and GOT
Access allowed between
GOT and programmable controller
Ethernet interface
(built-in)
IP: 192.168.3.18
Programmable controller
IP: 192.168.5.1
Ethernet communication unit
(option)
IP: 192.168.5.22
Access to other networks
not allowed
Register the IP address of the device to
prohibit access
Register the IP address of the device to
allow access
Ethernet
Ethernet
Unregistered IP address
Ethernet
Allowed IP address
Access
not accepted
Access
not accepted
Ethernet
Prohibited IP address Unregistered IP address
Prevent unauthorized access by
registering IP addresses in advance
[IP filter function]
Registering the IP address of the
device which is allowed to access
the GOT can prevent the access
from unauthorized devices.
3. 3) Reduce the overall communication load in the network
By separating the network, you can reduce the overall communication load in the network and avoid communication
performance deterioration.
Ethernetbusybusybusy
System with one network System with two networks
Ethernet
Network 1One network
Network 2
Heavy
communication
load!
Heavy
communication
load!
4) Enable visualization at production site
Using two Ethernet ports and the wireless network can offer a wide range of remote solutions for various applications!
The GOT remote solutions increase work efficiency from startup, adjustment, to maintenance with various remote
monitoring and operation functions that use mobile devices and personal computers.
Personal computer
IP: 192.168.3.1
Personal
computer
IP: 192.168.3.2
Ethernet
Ethernet
Ethernet interface
(built-in)
IP: 192.168.3.18
Personal computer
IP: 192.168.3.3
Programmable controller
IP: 192.168.5.1
Ethernet
communication unit
(option)
IP: 192.168.5.22 Wireless LAN
communication unit
(option)
IP: 192.168.4.20
Personal computer
IP: 192.168.4.4
Smartphone
IP: 192.168.4.1
Tablet
IP: 192.168.4.2
Personal computer
IP: 192.168.4.3
Information
system network
(office)
Control system network
(production site)
Wireless networkSoftGOT-GOT link function VNC server function
Personal computer
IP: 192.168.3.10
* To be
supported
soon
* To be
supported
soon
FA transparent function GOT Mobile function
VNC server function
Personal computer
IP: 192.168.4.10
FA transparent function
GOT Mobile function
* To use the GOT Mobile function, the GOT Mobile function license (GT25-WEBSKEY) is required separately.
The wireless LAN communication unit (GT25-WLAN) of the GOT can be used as an access point.
* To use the VNC server function, the license (GT25-VNCSKEY) is required separately.
* To use the SoftGOT-GOT link function, the license key (GT27-SGTKEY-U) is required separately.
For the devices that can be connected with GOT when using the Ethernet interface (built-in), the Ethernet communication unit (option), or the
wireless LAN communication unit (option), please refer to the "Connectable device list" on the back cover. For the details of remote monitoring
and operation functions, please refer to the Mitsubishi Graphic Operation Terminal GOT2000 Series Catalog (L(NA)08270ENG).
[Safety precautions]
If remote monitoring and operation functions are used to perform remote control of control equipment, the field operator may not notice the remote
control, possibly leading to an accident. In addition, a communication delay or interruption may occur depending on the network environment,
and remote control of control equipment cannot be performed normally in some cases. Before using the functions to perform remote control, fully
grasp the circumstances of the field site and ensure safety.
Data flow of remote monitoring
and operation functions
Data flow of FA transparent function
and SoftGOT-GOT link function
Data flow of the control system network
4. External dimensions
GOT
7(0.28)97.5(3.84)4.5
(0.18)
63 (2.48) 27.5
(1.08)
3
(0.12)
31.5 (1.24)
20
(0.79)
8.5
(0.33)
21.5(0.85)
Unit: mm (inch)
Specifications of Ethernet communication unit
Performance specifications
The performance specifications of the Ethernet communication unit are indicated below.
The general specifications of the Ethernet communication unit are the same as those
of the GOT. For the general specifications of the GOT, please refer to the GOT2000
Series User's Manual (Hardware).
Item Specifications
Transmission
specifications
Data transfer method 100BASE-TX 10BASE-T
Transmission method Base band Base band
Maximum node to
node distance
200m 200m
Maximum segment
length
100m 100m
Maximum number of
cascade connection*1 2 steps 4 steps
Number of units mounted to GOT
Only 1 unit can be mounted to
the extension unit interface.
Connection
conditions
Number of connectable
equipment
128 (recommend 16 or less)*2*3
Installation distance 100m*2
Internal current consumption (5 V DC) 0.14A
Weight 0.07 kg (0.15 lb)
*1 Indicates the maximum number
of connectable nodes when using
repeater hubs. For the maximum
number of cascades when using
switching hubs, contact the
switching hub manufacturer.
*2 This depends on the specifications
of the Ethernet network system to
which the GOT is connected. For
the details, refer to the manual
of Ethernet module of connected
programmable controller.
*3 If multiple pieces of network
equipment (including GOT) are
connected within a segment, the
network load would increase. In
such condition, the communication
performance between GOT and
programmable controller may be
declined. The communication
performance may be improved by
the following measures.
•Using switching hubs
•Reducing the number of
monitoring points on the GOT
Product list
Product name Model Specifications
Supported model
GT27 GT25 GT23 GT21
Ethernet
communication unit GT25-J71E71-100 Data transfer method: 100BASE-TX, 10BASE-T
Compatible software: GT Works3 Ver.1.160S or later ™ ™ − −
* BootOS version Z or higher is required to use the Ethernet communication unit.
* For the conformed standards of the product, please contact your local sales office.
*1 The FA transparent function will be supported soon for the configuration using Ethernet connection between GOT and a personal computer and
Ethernet connection between GOT and a programmable controller.
*2 The following functions will be supported soon: data transfer from GT Designer3 to GOT, the FA transparent function from engineering software
(MELSOFT GX Works3, etc.), the SoftGOT-GOT link function from GT SoftGOT.
*3 Data transfer cannot be performed from a personal computer that is connected to the programmable controller.
*4 TOSHIBA Unified Controller nv Series cannot be connected.
Connectable device list
Ethernet interface*1 (built-in)
Ethernet communication unit*1 (option)
GT25-J71E71-100
Wireless LAN
communication unit*1
(option)
GT25-WLAN
Wireless LAN access point
Wireless LAN access point
š Connectable
Ï Not connectable
Personal
computer
Mitsubishi
programmable
controller
Non-Mitsubishi
programmable
controller
GOT
GOT
GOT Microcomputer
Smartphone,
tablet
Personal
computer*2
GOT
GOT Mitsubishi
programmable
controller*3
Non-Mitsubishi
programmable
controller*4
Microcomputer
Smartphone,
tablet
Personal
computer
Mitsubishi
programmable
controller
Non-Mitsubishi
programmable
controller
Microcomputer
Smartphone,
tablet
Precautions for safe use
Precautions for safe use
To use the products given in this publication properly, always
read the relevant manuals before beginning operation.
ETHERNET is a registered trademark of Xerox Corp.
Other product and company names are either trademarks or
registered trademarks of their respective owners.
The release date varies depending on the product and your region. For details, please contact your local sales office.
The actual color may differ slightly from the pictures in this catalog. The actual display may differ from what are shown on
GOT screen images.
HEAD OFFICE: TOKYO BLDG., 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN
NAGOYA WORKS: 1-14, YADA-MINAMI 5, HIGASHI-KU, NAGOYA, JAPAN
Country/Region Sales office
USA ····················+1-847-478-2100
Mexico ················+52-55-3067-7511
Brazil ···················+55-11-4689-3000
China ··················+86-21-2322-3030
Taiwan ·················+886-2-2299-2499
Korea ··················+82-2-3660-9530
Singapore ···········+65-6473-2308
Thailand ··············+66-2682-6522 to 31
Indonesia ············+62-21-3192-6461
Vietnam ···············+84-8-3910-5945
India ····················+91-20-2710-2000
Australia ··············+61-2-9684-7777
Germany ·············+49-2102-486-0
UK ·······················+44-1707-28-8780
Italy ·····················+39-039-60531
Spain ··················+34-935-65-3131
France ················+33-1-55-68-55-68
Czech ·················+420-251-551-470
Turkey ·················+90-216-526-3990
Poland ················+48-12-347-65-00
Russia ·················+7-812-633-3497
South Africa ········+27-11-658-8100
L(NA)08424ENG-A 1611[IP]
New publication, effective Nov. 2016.
Specifications are subject to change without notice.