4. KINGSUMarketingCorporation
4631ArellanoAvenue, Palanan, Makati City;
Tel. No. (02)550-1858/ (02)552-7099 ; Fax No. (02)550-1927;
Email:kingsuco@gmail.com
Substation Structures
Valmontprovidespoles and structures thattransports anddistribute electricity. To
help meet the stringent needs of public and private utility companies, we offer a
comprehensive series of utility structures and engineering services. Valmont
operates over 100 factories in the world including 6 galvanized steel poles
factories inAsia Pacific.
Valmont, world largest manufacturer of
galvanized steel distribution poles,
transmission monopoles and substation
structures from 11kV to 500kV. We are
pioneer in the pole business supply over
100,000 steel pole every year.
5. KINGSUMarketingCorporation
4631ArellanoAvenue, Palanan, Makati City;
Tel. No. (02)550-1858/ (02)552-7099 ; Fax No. (02)550-1927;
Email:kingsuco@gmail.com
Transmission and
Distribution Steel Poles
Valmont’s poles are world renowned for their
quality, durability and reliability. Our tapered
tubular steel poles are essential for many of the
world’s high-voltage systems for a variety of
reasons: flexibility, ease of installation, uniform
material strength, low maintenance
requirements andcorrosion protection.
8. KINGSUMarketingCorporation
4631ArellanoAvenue, Palanan, Makati City;
Tel. No. (02)550-1858/ (02)552-7099 ; Fax No. (02)550-1927;
Email:kingsuco@gmail.com
PowerTransformer
Civilizations have always
required energy…
Takaoka is engaged in activities
aimed at supplying clean energy
for work in many fields, including
power plants and power
distribution systems, which are
the arteries that support the
affluent communities of today.
12. KINGSUMarketingCorporation
4631ArellanoAvenue, Palanan, Makati City;
Tel. No. (02)550-1858/ (02)552-7099 ; Fax No. (02)550-1927;
Email:kingsuco@gmail.com
CAT No. FLV08958-2
Grip-all Clampstick , Light Model; Total
Length 2.04m (6.5ft);
Insulating Length: 0.74m (2.5ft);
2.50kg. (5.51 lbs)
CAT No. RC403-0293
Grip-all Clampstick Regular Model
Dia 32 X 2,650MM (L)
Disconnect Hot Sticks
CAT No. RH3046-17
Spliced Disconnect Stick,
Light Model x32 x 3,650mm
CAT No. RH3146-12
Disconnect Stick-2 Section
Spliced
Sectional Model with Rigid Splice (2 sections)
Grip-all Clampsticks
LeverType Wire Cutters
CAT No. RH1871-6
Lever Type Wire Cutters, Max 2/0
Used for cutting aluminum ACSR, ASC and copper wires, these cutters are assembled
with Ritzglass insulating poles; Max. Conductor Size: 1/0 ACSR, dia 10.11mm (0.4"); Stick
dimensions: dia 32m (1.25"); Total length: 2.0m (6.5ft.); Insulating length: 1.16m (40ft.);
4kg (8.82 lbs)
13. KINGSUMarketingCorporation
4631ArellanoAvenue, Palanan, Makati City;
Tel. No. (02)550-1858/ (02)552-7099 ; Fax No. (02)550-1927;
Email:kingsuco@gmail.com
Hot line Ladder
LADDERSWITH ∅ 51 mm SIDERAILS
Cat. No.
(8” Hook)
Insulating Length Distance Between
Rungs
Approx. Weight
RH4904-10 3.00 10.0 0.30 1.0 22.90 50.49
m ft. m ft. kg. lb.
Insulated Rubber Blanket
CAT No. LR-4/11
SOLID TYPE,
900x900mm, Class 4
Color Orange;
Nominal Working Voltage:
36kv Nominal Test Voltage:
40kv
CAT No. LR-SP-4/11
SLOTTED TYPE,
900X900MM, Class 4
Color Orange
Nominal Working
Voltage: 36kV
Nominal Test Voltage:
40kV
14. KINGSUMarketingCorporation
4631ArellanoAvenue, Palanan, Makati City;
Tel. No. (02)550-1858/ (02)552-7099 ; Fax No. (02)550-1927;
Email:kingsuco@gmail.com
CAT No. COB08835-1(FLV3631)
CONDUCTOR PROTECTIVE COVER,
Nominal Voltage: 36.3kV (phase-to-
phase)
CAT No. RC406-0181GA
CONDUCTOR COVER –
For conductors up to 25mm (dia) (1"),
method for distance; 2.00kg (4.41 lbs)
Nominal Voltage: 26.4kV (phase-to-
phase)
CAT No. RM4931
CONDUCTOR COVER –
High Voltage Conductor Protective
Cover Up; 48kV
To be installed up to (dia) 45mm
(1.8") conductor by hot stick
CAT No.RC406-0091
PIN INSULATOR COVER-UP -
Provided with fitting system
on both ends;
Nominal Voltage: 48.3KV
(phase-to-phase)
CAT No. RC406-0046
PIN INSULATOR with holders
for stick method; 4.20kg
(9.26 lbs.);
Nominal Voltage: 48.3kV
(phase-to-phase)
ConductorCovers, Pin InsulatorCovers, Disc
InsulatorCovers & Pole Covers
15. KINGSUMarketingCorporation
4631ArellanoAvenue, Palanan, Makati City;
Tel. No. (02)550-1858/ (02)552-7099 ; Fax No. (02)550-1927;
Email:kingsuco@gmail.com
CAT No. RC406-0000
POLE COVER
1,800MM (5.9ft.)
Overall Length, Nominal Voltage
36.6kV (phase-to-phase)
CAT No. RC406-0164
DISC INSULATOR COVER-UP - Protector
to disc up to diameter 254mm (10");
ConductorCovers, Pin InsulatorCovers,
Disc InsulatorCovers & Pole Covers
CAT No. RM-4947
PIN INSULATOR PROTECTIVE
COVER-UP - With metallic bracket;
CAT No. RM-4937-6
POLE COVER,
230mm, 1,800MM Overall
Length, 36.6kv (Phase To Phase)
CAT No. RC406-0182
PIN INSULATOR COVER-UP
(H) 153mm (0.5ft.) with metallic bracket for
hot stick installation; 1.10kg (2.43 lbs.)
Super Testers
CAT No. H-1990-ST-
138
SUPER TESTER138KV
Single-pole Non-
contact High Voltage
Detector, For Systems
From 1 Through138kv
16. KINGSUMarketingCorporation
4631ArellanoAvenue, Palanan, Makati City;
Tel. No. (02)550-1858/ (02)552-7099 ; Fax No. (02)550-1927;
Email:kingsuco@gmail.com
Grounding Clamps forTransmission
Lines, High and Extra-HighVoltage
Substations
CAT No. ESR-19898-6
AERIAL DAYLIGHT WARNING SPHERE;
600mm diameter, for conventional
instalation for cable diameters ranging from
12.51mm to 13.5mm
Daylight Warning Spheres
CAT No. RHG4229-6SJ
GROUNDING CLAMP FOR TRANSMISSION LINES;
Main Body In Aluminum; Serrated Jaw; Tightening
Screw In Bronze Attached To As Ø 32 mm X 1.83 M
Ritzglas® Pole; Bronze Cable Connectors For Plain
Ferrules. Provides Operation To Continuous Angles
Of Up To 75°.
30. KINGSUMarketingCorporation
4631ArellanoAvenue, Palanan, Makati City;
Tel. No. (02)550-1858/ (02)552-7099 ; Fax No. (02)550-1927;
Email:kingsuco@gmail.com
ASTM D120 – Standard Specification for Rubber Insulating Gloves
Our gloves are labelled according to specification as per the table below:
EN60903: Live Working – Glove of Insulating Material
UnderEV60903, our glove also pass certain special properties which are classified by the additionof suffixes as follows:
37. KINGSUMarketingCorporation
4631ArellanoAvenue, Palanan, Makati City;
Tel. No. (02)550-1858/ (02)552-7099 ; Fax No. (02)550-1927;
Email:kingsuco@gmail.com
METER PLATE COVER
• For RingType Watthour Meter Socket
• With 4-dummy blades that fit to the terminal
jaws of the KWH meter socket
• Material : PlainTransparent Sheet CM 205
METER DISCONNECT SLEEVES
• MinimumThickness ofWall: 0.127
• Minimum DielectricStrength: 3,200Volts
POLYCARBONATE KWH METER COVER
• Sabic SLX 2271t
• GenericTo Fit GEI-70S, Westinghouse D4s & D5s,
Sangano/Schlumber J4S & J5S And Abb’s Ab1
• Single Phase KWH Meters
Fabricated Products for Metering
METER SEALING RING
• Slip-lock type
• SUS304-13A
• Material : PlainTransparent Sheet CM 205
38. KINGSUMarketingCorporation
4631ArellanoAvenue, Palanan, Makati City;
Tel. No. (02)550-1858/ (02)552-7099 ; Fax No. (02)550-1927;
Email:kingsuco@gmail.com
Fabricated Products for Metering
METER CRATE (Case)
• Durable, High Strength Place
• Holds up to six (6) watthour meters
• Stackable with both single phase & poly
phase meters
• Protect meters for transport of storage
• Convenient for lab or field
ELECTRONIC POLYPHASE CABINET
• Size: 565mm (L) x 342mm (W)
• Made up of 100% stainless steel sheet with
magnetic shielding
OUTDOOR CURRENTTRANSFORMER
CABINET
• For 200 to 600 amp transformer
• Made up of 100% stainless steel sheet with
phenolic board sliding