2. luto llrain Ttap
ililE milfil $olenoid Ualue
O Solenoid controlled valve receives compression pressure
directly that there are a lot of disabilities.
I Time setting by condensate volume is difficult that air loss is big.
O When discharge noise is heavy.
F1OAT TYPE
3 Nozle caliber is small structurally that is often blocked so that
there needs periodic dissolution and cleanrng (0.7@).
I lf alien substance rises at Float Nozzle is not closed that air
loss is occurred continuously,
I In case of oil supply compressor, density of oil drops
Float's bpoyancy.
iIAIIUAI lUE
I Compressed air making by expensive power
is emitting into air for condensate discharge.
Working pr re ; 7.0 ksf/crr
t diameter : 36 bi loss amount - 0,6559nr'/min)
Running time'. 24hr I day
CoS of compressed air per 1m' : About
.l0
wons
0.6559m'iminx60min/hrx24hr/dayx365dayx1 nln' =
3.2147.400w0n
IIEAN tilA$ItR
O Air leakage is so little that economic effect is excellent,
and withdrawal of early investment expense is fast.
I Outlet diameter is large (inside diameter 12Ql that
there is no block phenomenon, and it is safety
because there is restoration abilitv when converts to
emergency mode.
O All operations are automated that control is easy.
I Model is various from small to high-capacity
according to capacity of using compressor.
3. Why happens condensatefl
* Compressor inhales air from atmosphere and saturated
vapor that is flowed when compress becomes water in
compressron process.
* In the case of condensate, was polluted extremely by
dust in air, pollutant, oil etc., in the case of oil free
compressor, it is acidified that causticity is strong
Condensate! What is DroilemP
* Conodes and contaminates compressed air piping, air
tank, air filter etc., and lurthermore, it gives serious
effect to high equipment and product in production
field.
I In the case of winter. condensale is exposed to
danger of burst by frozen in piping and machine
equipment
llecessity of auto drain tran.
lTo prevent damage of condensate, there are used
existing trap of ball float method and timer method, but
these have fatal weakness that are often blocked or
flow out much expensive compressed air.
a DRAIN MASTER has equipped authoritative and
convenient nature for condensate discharoe that can
give epoch-making change to existing condensate
discharge system.
10,000
8,0m
6,000
4,000
2,000
t-
Year condensation quanl ty that is happened Air 0cmpressor(TSkWlSystem
1 2 3 4 5 6 7 B 9 10 11 12'!r.^'
0RAIll IIIASIER 0peration Principle
Figure 1 : Condensate that flowed in through lead-in line {1} is
gathered in housing O, and upper space of diaphragm rs,
through pilot control line iO becomes dynamic pressure.
lf diaphragm seat upper space becomes dynamic pressure,
diaphragm is closed by spring pressure and it prevents
escaoes ot compressed air.
Figure 1
Figure 2 : €) 11 condensate water level rises in housing, it is sensed in the high level sensor
('6t and solenoid controlled valve is begun action and close supply line,
compressed air in diaphragm upper space becomes atmospheric pressure
state bY venting.
Then, diaphragm of valve O lifting by pressure of inflow line, condensate is
discharged to outside through drain iine i-01
Figure 2
4. Electlostatic canacity $ensol
Any condensate from compression process can be sensed correctly and
discharged.
Iherc are little loss of Gom[]esscd ail.
Uses of two sensors (High level, low level) protects energy loss by air loss
discharging condensate selectively
'"*.......'''..'''-''
{'t
a)
"l::rr-
llcic
0igital Countins Indicatoil|lni0nl
- Daily, Total counting
- Counting reset
- Counting range : 999,999
0urability tHard-Anodizingl
Housing coated rigid coating applyrng for aircraft, semiconductor
equipment etc. of industrral equipment required durability is
excellent nature of rust proof durability and abrasion etc. so that life
of housing is semi-permanent.
Uariou$ model, beautiful design
Extended user's selection by subdividing into three models
according to quantity of condensate, and housing is
processed by anodizing method and die casting mold
that has beautiful design.
Automatic discharge f unction
ln case oi condensate is not discharged while 2 minutes by scale
etc., it makes recognition to user through alarm signal and it is
converted to automatic restoration function and it activates
electric motion ball valve by 5 seconds every 3 minutes. lt ts
returned by normally mode if discharge is achieved normally.
Gonuenlence 0f install and maintenanco
,:-: Put lead-in line more than 2 lines so that power connection is easy,
and pjping is convenient.
, Housing internal pollutant cleaning is simple,
.rr The built-in strainer can prevent the breakage of valve by the sludge
and phenomenon to be blocked
5. R
NCHilIGAI IIAII
::. Green : Dry and cool climate(such as in Northern Europe,
Canada. Northern states of the USA" Central Asia)
Blue : temperate climate(such as in Central and Southern
Eurooe. Central Americall
:-:,.' Red : humid, troprcal climate(such as in the coastal regrons
o[ Soutn-East Asia, Oceania. Amazon and Congo regions)
IRAIil
MASTER
TH6N
m50
drll50
u$€m
DilLl5m
Iil}IsTP
Dtit€t}|P
dlllcl}tP
0tilEilstoll
P€k Peak
Cornpressor i Dryer i npdi:atlcn
i (.)
Climate
zdle
n9
Pressure
mtn I nEx
(bar)
P
-1:
Filter
m3lmin
Green 8
Hw7
Red 5
Ct'eff 24
Sue 21
Red 15
Geen 80
Blue 70
Red 50
Green 170
Blue 150
Red 105
Geen 570
Bue 500
Red 3S
Geen 1750
Blue 1500
Red 50
C*een 170
Blue 150
i Pe{ftrrnance Perftnnance
I rn3/min rn3/min
16 80
14
'10
4
42
30
160
140
100
340
300
210
fiq
1000
700
3500
3000
21ffi
48
a
30
160
140
100
340
300
70
qn
240
210
'150
800
700
500
17ffi
1500
10s
5700
5000
3500
- - ;;---
AB
AB
AB
AB
A.B
AB
AB
AB
0.8/16
0.8/16
1,?Jffi
1.260
1
+1/80
+1/80
+1180
+1i80
+1/80
+1i80
+1180
+1/80
+1180
0 8/16
0 8/16
0 8/16
0 &16
240
210
150
800
700
1 700
1 500
H
-a
f ' ';::r-; ' "' -.
1 :
---
-.-
H L
'[;.
!i __-::-1 -),:: :i':
r
_- _
-
-i-x-
,.. .'-
-::-.--:7
;FI r.,
t
'E---
--- L,
w _ Dw-1500
i a E -' D[/-15.50150500
-*ry.1
: :..*------:-L, i
6': E a i Dtu1-1550.'150HP
-w*=
"Applic6lion: A.oii contamrnaled condensale ; B oil free. aggressive condensate
DRAINMASTER
Ccxrdensate Feed
Condensate Disdarge
Fbusing Mataial
wbrght(lQ)
Dilt.sH Di't.t5
112'x2
3/8',
1 30 1 65 220 3 30 5.30
Dir.50 Drs.tlro DM.s(xt DM-ts(xt DM.iSHP DM€O|{P DM.r50HP
314'x3 1'x1 .314x2 1i2"x2 3i4 x3
1i2' 3iB
Free voltase 90-260Vac, 24 ! 4BY dc, 24 1 48"/ ac
Aluminium, Hardcoated
195 250 405
1 63x71x1 85 1 83x8$r1 93 22ix110x204
730
Dimensbn(V&l-xHmm) li64*80*154 163x71x178 i83x80x187 22ixl10x193 2/1x160x213 349x180x247
> lvlusf attach automatic Lhermoslat(option : Heater/l10 2z}'lac) n freezing area
) Else above n,odeis are cuslonr-bui l.
) Above speclicaiion can be changed wthoui advance notrce foi rmprovemenl ol per'lormance(2013 01)
6. Head office: EnE SYSTEM CO.,Ltd #290, Goryeom-ri, Cheongbuk-myeon, Pyeongtak-si, Gyeonggi-do, Korea
URL:wwwenes!,slemcorn E-marl :enesystemldenesystemcom I.82-31-2y-4tn1 F:82-31-2U-4222