5. The air we breathe contains roughly 78% nitrogen, 21 % oxygen, .9% argon and the balance is other gases. The oxygen is separated from the air using PSA Technology. The process centers around a molecular sieve known as Zeolite. At high pressures the sieve adsorbs or attracts nitrogen, and at low pressures it desorbs or releases nitrogen. The On-Site generator consists of two tanks filled with sieve. As high pressure air (about 70 psi) is introduced into the first tank, it passes through the sieve and nitrogen is adsorbed. The remaining oxygen and argon are piped to a buffer or storage tank. Just before the first tank becomes completely saturated with nitrogen, feed air is redirected to the second tank which then repeats the above process. The first tank is then vented to atmosphere which allows the nitrogen to desorb or release from the sieve. To complete the regeneration of the first tank, a small amount of the oxygen is used to purge it. This process is completed over and over again until the demand for oxygen is met. Under normal operating conditions, which includes the use of clean dry air for separation, the sieve will last indefinitely.
6. Auto change over Cylinder Oxygen Supply for Back Up Check valve (5 psi cracking pressure) Motorized shut off valve Manual ball valve Basic System Schematic Per HTM2022 Back up Primary reserve Bacteria filter Oxygen analyzer Compressed air system Oxygen Generator Module Air compressor Air dryer Air receiver Oxygen generator O 2 receiver O 2
7.
8. Automated Control & Plant Monitoring (LCD Panel) Touch sensitive LCD Screen Start / Stop Thermal mass Flow meter Oxygen purity monitor Alarm buzzer Power on / off Phase indicator
9.
10. Project References in Oil and Gas, Medical And Hospitality N2 (NITROGEN) and O2 (OXYGEN)
11.
12. GASTEC AS-450 Non-filling Plant Flow Rate = 11.8 m3/hour Purity = 94% Output Pressure = 4.5 Bar max (As per HTM2022 standards) RSU SANTO ANTONIUS Pontianak, Kalimantan Barat INDONESIA GASTEC® POPULATION IN INDONESIA & OTHERS GasTec O2 Generators (RENTAL)
13. PAPUA NEW GUINEA GASTEC High Purity Oxygen Filling Plant Flow Rate = 60 cylinders / day Output Pressure = 150 Bar max Purity = 99% GASTEC® POPULATION IN INDONESIA & OTHERS
14. RSUD MATARAM Mataram, NUSA TENGGARA BARAT GASTEC AS-160 Filling Plant Purity 94% Flow Rate = 3.2 m3/hour or Maximum 465 cylinders per month GasTec O2 Generators (RENTAL)
15. RSUD Dr. M. YUNUS Bengkulu, Prov Bengkulu GASTEC AS-250 Filling Plant Flow Rate = 6.57 m3/hour 555 tabung (@6m3) per month Power consumption = 18.5kW Total GasTec O2 Generators (RENTAL)
16. RSUD PRAYA Lombok Tengah NUSA TENGGARA BARAT GASTEC AS80 Filling Plant Flow Rate = 2.1m3/hour or 233 cylinders (@6m3) per month
19. GAS GENERATORS PHILIPPINES INC. 1702,17th Floor, Jolibee Center. San Miguel Office, Ortigas Center, Pasing. Metro Manila. Philippines. Tel : 6326386808 Fax : 6326382590, 6326386808 Contact: Dr Francis G Lavilla, M.D., President/CEO COTMAC GASTEC PVT. LTD S-168, 'S' Block, MIDC, Bhosari, Pune - 411 026 Maharashtra, India Tel: +91-20-30687200/30687120 Fax : +91-20-27119870 Contact: Pralhad Hage, Director Contact Us: GAS GENERATORS (MALAYSIA) SDN BHD Lot 5189, Unit 2, Sg. Ramal, Off Tanming Jaya 43300 Balakong, Selangor, Malaysia Tel: 603-8961 3390 Fax : 603-8962 3390 Contact: Eric Tan, CEO PT.RINDANG PARI CAHYA BUANA Affiliated with PT GAS GENERATORS INDONESIA Wisma Rindang Pari, Jl. Perjuangan Raya, no 7 - 8 Kebon Jeruk, Jakarta 11530, Indonesia Telp. : 0813 8746 1995; 085888770081 info: mj_jkt@yahoo.com UNIVERSAL GAS GENERATORS (THAILAND) Co. Ltd. 3/3 Soi Saladaeng Road, Silom, Bangrak, Bangkok 10500, Thailand Tel: +66 2233 3546 Fax: +66 2235 5900 Contact: Lee Szu Yang, Managing Director GAS GENERATORS (JAPAN) Co. Ltd. 2- Chome, 1-18 Kitayoshizu-Cho Fukuyama, Hiroshima 720-0073, Japan Tel +81-84-973-9302 Fax +81-84-926-3367 Contact: Tateishi, Managing Director