Boiler lecture 29 JULY.pptx

R
The boiler as a steam
generator.
Steam Generators/Boilers
• “A combination of apparatus for producing, furnishing or
recovering heat together with apparatus for transferring
the heat so made available to water which would be
heated and vaporized to steam form” (ASME).
• Basis for classification of boilers
o Contents inside the tube
o Firing system
o Position of drum
o Pressure
o Nature of water circulation
Water Tube and Fire Tube Boilers
Requirements of a Good Boiler
• Low cost of installation, operation and maintenance
• Easy maintenance
• High efficiency
• Safety
• High transportability
• High steam production rate
• Good quality of steam
• Quick steam generation capacity
• Meeting fluctuating demand of steam
Cochran Boiler
Babcock and Wilcox Boiler
Locomotive Boiler
Lancashire Boiler
Boiler lecture 29 JULY.pptx
Boiler Accessories
• Economiser
• Air preheater
• Super heater
• Steam trap
• Steam separator
• Injector
Economiser
Air Preheater
Superheater
Steam Separator
Boiler Performance
Heat loss in the boiler
Heat balance sheet
E-1
E-2
E-3
ECONOMISER
EVAPORATOR
STEAM
DRUM
SUPERHEATER
• 1. Introduction,
• 2. Equivalent Evaporation
• 3. Boiler Efficiency.
• 4. Boiler Trial
• 5. Heat Losses in a boiler
• 6. Heat balance sheet
• Introduction
• The performance of a steam boiler is measured in
terms of its ‘evaporative capacity
• In actual practice, the feed water temperature and
working pressure varies considerably.
• The feed temperature usually adopted is 100° C
and the working pressure as normal atmospheric
pressure, i.e. 1.013 bar. It is assumed that the
boiler is supplied with water at the boiling
temperature (100°C) corresponding to the
atmospheric pressure.
Equivalent evaporation
• It is the amount of water evaporated from feed
water at 100° C and formed into dry and saturated
steam at 100° C at normal atmospheric pressure. It
is, usually, written as “from and at 100 °C”
• As the water is already at the boiling temperature.
it requires only latent heat at 1.013 bar to convert
it into steam at the temperature (100° C). The value
of this latent heat is taken as 2257 kJ/kg. (hfg at
100°C)
Boiler lecture 29 JULY.pptx
Equivalent evaporation E
me = Kg/h or kg/kg of fuel burnt
Is called the factor of evaporation Fe and is
always greater than unity for all boilers.
𝐹𝑒 =
ℎ − ℎ𝑓1
2257
Boiler Efficiency
• It may be defined as the ratio of heat actually used in
producing the steam to the heat liberated in the
furnace. It is also known as thermal efficiency of the
boiler.
Worked example
• A boiler was used to produce wet steam at 11 bar with a
dryness fraction of 0.8 from water at 12 C. Fuel is supplied to
the furnace of the boiler at a rate of 325 kg per hour. The
calorific value of the fuel is 35700 kJ/kg. The mass of water
supplied to the boiler in
5 hrs 23 minutes = 15630 kg.
• The mass of water was measured before and after the steam
generation process and it was discovered that in order to
restore the original level in the boiler 1200 kg of water was
required.
• Evaluate:
• Actual evaporation per kilogram of coal
• Equivalent evaporation from and at 100 C
• Thermal efficiency of the boiler.
Performance of Boilers
• Evaporation Rate: It is steam generation rate of boilers
which may be expressed in terms of kg of steam per unit
heating surface area or kg of steam per cubic metre of
furnace volume or kg of steam per kg fuel burnt.
• Equivalent Evaporation: It is equivalent of energy of
evaporation of 1 kg of water at 100°C to dry and
saturated steam at 100°C, standard atmospheric
pressure of 1.013 bar. Hence, the equivalent
evaporation of 1 kg of water at 100°C needs 2,257 kJ.
• Factor of Evaporation: It is ratio of heat absorbed by 1 kg
of feed water under working conditions to latent heat of
steam at atmospheric pressure.
• Boiler Efficiency: It is ratio of heat absorbed by
water in boiler to heat supplied to boiler per unit
time.
Thank You.
Boiler lecture 29 JULY.pptx
Worked example
• A boiler was used to produce wet steam at 11 bar with a
dryness fraction of 0.8 from water at 12 C. Fuel is supplied to
the furnace of the boiler at a rate of 325 kg per hour. The
calorific value of the fuel is 35700 kJ/kg. The mass of water
supplied to the boiler in
5 hrs 23 minutes = 15630 kg.
• The mass of water was measured before and after the steam
generation process and it was discovered that in order to
restore the original level in the boiler 1200 kg of water was
required.
• Evaluate:
• Actual evaporation per kilogram of coal
• Equivalent evaporation from and at 100 C
• Thermal efficiency of the boiler.
Boiler trial
The main objectives of a boiler trial are:
1. To determine the generating capacity of the
boiler.
2. To determine the thermal efficiency of the
boiler when working at a definite pressure.
3. To prepare heat balance sheet for the boiler.
Heat loss in a boiler
• We know that the efficiency of a boiler is the ratio
of heat utilised in producing steam to the heat
liberated in the furnace.
• The heat utilised is always less than the heat
liberated in the furnace.
• The difference of heat liberated in the furnace and
heat utilised in producing steam is known as heat
lost in the boiler.
hf1
hf2
h3 = hf + x hfg
h4 = hsup
1
2
3
4
Evaporator Economiser
Superheater
Steam Drum
Heat lost to dry flue gases per kg of
fuel
Heat lost in moisture present in the
fuel
It is assumed that the moisture is converted into superheated
steam at atmospheric pressure 1.013 bar).
•Heat lost in moisture present in the fuel
heat lost to steam formed by combustion of hydrogen
per kg of fuel
4 The heat lost due to unburned
carbon per kg of fuel
Heat lost due to incomplete combustion of carbon to
carbon monoxide.
• This loss generally occurs in the boiler due to
insufficient air supply.
Heat lost due to radiation.
• There is no direct method for finding the heat lost
due to radiation. This loss is calculated subtracting the
heat utilised in raising steam and heat losses from the
heat supplied.
• A Heat balance sheet shows the complete account of
heat supplied by 1 kg of dry fuel and heat consumed.
The heat supplied is mainly utilised for raising the
steam and the remaining heat is lost.
Heat balance sheet
Heat supplied kJ Heat consumed kJ %
Heat supplied by
1 kg of fuel
Xf 1 Heat lost to dry flue gases per kg of fuel
2 Heat lost in moisture present in the fuel.
3 heat lost to steam formed by combustion
of hydrogen per kg of fuel
4 The heat lost due to unburned carbon per
kg of fuel
5. Heat lost due to incomplete combustion
of carbon to carbon monoxide.
6. Heat lost due to radiation etc.
X6 = Xf – (x1 + x2 + x3 + x4 + x5)
X1
X2
X3
X4
X5
X6
Example
• In a boiler the following observations were made
• Pressure of steam 10 bar
• Steam condensed 540 kg/hr
• Fuel used 65 kg/hr
• Moisture in fuel 2% by mass
• Mass of dry flue gas 9 kg/kg of fuel
• Lower calorific value of fuel 32000 kJ/kg
• Temperature of flue gases 325°C
• Temperature of boiler house 28°C
• Feed water temperature 50°C
• Mean specific heat (flue gases) 1 kJ/kgK
• Dryness fraction of steam 0.95
Draw up a heat balance sheet for the boiler
• Heat supplied by 1 kg of fuel
• =(1 - 0.02) x 32000 = 31360KJ
• Heat utilised in raising steam per kg of fuel
• From steam tables, for a feed water temp of 50°C
• hf = 209.3 kJ/kg
kg
31
.
8
65
540
m
m
me
f
s



• Correspondingly for steam at 10 bar
• hf = 762.6 kJ/kg, hfg = 2013.6kJ/kg
• Heat utilised in raising steam per kg of fuel
• Heat carried away by dry flue gas
    kJ
t
t
c
m b
g
pg
g 2673
28
325
1
9 






   
  kJ
h
xh
h
m
h
h
m f
fg
f
e
f
f
e
20495
3
.
209
6
.
2013
95
.
0
6
.
762
31
.
8
1
1
2












• Heat carried away by moisture in fuel per kg of fuel
• From tables @ 28°C, hb = 117.3 kJ/kg
• Heat carried away by moisture in fuel
 
 
 
  kJ
h
t
c
m b
g
p
m
6
.
60
3
.
117
100
325
1
.
2
2676
02
.
0
100
2676










Cp for steam = 2.1 kJ/kgK
Heat balance sheet
Heat supplied kJ Heat consumed kJ %
Heat supplied
by 1 kg of
fuel
31360
1 Heat utilised in raising steam
2 Heat carried away by flue gases.
3 Heat lost in moisture present in the
fuel.
4. Heat lost due to radiation etc.
X6 = Xf – (x1 + x2 + x3)
20495
2673
60.6
= 8131.4
Totals 31360 31360
The following particulars were recorded during a steam
boiler trial
Pressure of steam = 11 bar;
mass of feed water = 4600 kg/hr;
Temperature of feed water = 75C;
dryness fraction of steam = 0.96;
coal used 490 kg/hr;
calorific value of coal 35700 kJ/kg;
Moisture in coal 4% by mass;
Mass of hydrogen in fuel 18% by mass
mass of flue gases 18.57 kg/kg coal;
temperature of flue gases = 300C;
Boiler house temperature = 16C;
specific heat of flue gases = 0.97 kJ/kg K
Draw the heat balance sheet of the boiler per kg of
In a boiler trial, the following observations were obtained.
Pressure of steam = 8.5 bar;
mass of feed water = 1520 kg/hr;
Temperature of feed water = 30C;
dryness fraction of steam = 0.95;
coal used 200 kg/hr;
Ash and unburnt coal collected = 16 kg/hr
Calorific value of ash and unburnt coal = 3780 kJ/kg
calorific value of coal 27300 kJ/kg;
Moisture in coal 4% by mass;
mass of flue gases 17.3 kg/kg coal;
temperature of flue gases = 330C;
Boiler house temperature = 17C;
specific heat of flue gases = 1 kJ/kg K
Draw the heat balance sheet of the boiler per kg of coal.
Boiler lecture 29 JULY.pptx
Heat balance sheet
Heat supplied kJ Heat consumed kJ %
Heat supplied
by 1 kg of
(dry) fuel
(1-%m)CV 1 Heat utilised in raising steam per kg of
steam
𝑚𝑒 ℎ𝑓 + 𝑥ℎ𝑓𝑔 − ℎ𝑓1
2 Heat carried away by flue gases.
𝑚𝑔𝐶𝑝𝑔 𝑡𝑔 − 𝑡𝑏
3 Heat lost in moisture present in the fuel.
𝑚𝑚 ℎ𝑔 + 𝐶𝑝𝑠 𝑡𝑔 − 100 − ℎ𝑏
4 Heat lost in water formed from
hydrogen present in the fuel.
𝑚𝐻𝑦𝑑𝑟𝑜𝑔𝑒𝑛 ℎ𝑔 + 𝐶𝑝𝑠 𝑡𝑔 − 100 − ℎ𝑏
4. Heat lost due to radiation etc.
X6 = Xf – (x1 + x2 +x3 +x4)
Totals
1 sur 48

Recommandé

Formation and properties of steam par
Formation and properties of steamFormation and properties of steam
Formation and properties of steamAnuharsh Gaur
6.3K vues21 diapositives
Boiler performance (Part 1) - Equivalent evaporation - Notes par
Boiler performance (Part 1) - Equivalent evaporation - NotesBoiler performance (Part 1) - Equivalent evaporation - Notes
Boiler performance (Part 1) - Equivalent evaporation - NotesAVDHESH TYAGI
2.4K vues18 diapositives
Chapter waste heat recovery p18 par
Chapter waste heat recovery p18Chapter waste heat recovery p18
Chapter waste heat recovery p18Nikolay Mavrodiev
1.9K vues18 diapositives
Analysis of Steam Cycles par
Analysis of Steam CyclesAnalysis of Steam Cycles
Analysis of Steam CyclesDr. Rohit Singh Lather, Ph.D.
2.3K vues39 diapositives
287649737 90325-presentation-hrsg par
287649737 90325-presentation-hrsg287649737 90325-presentation-hrsg
287649737 90325-presentation-hrsgSrikanth321
1.5K vues17 diapositives
Steam power plant par
Steam power plantSteam power plant
Steam power plantMohitSinghal71
411 vues21 diapositives

Contenu connexe

Tendances

Brayton cycle par
Brayton cycleBrayton cycle
Brayton cycleUniversity of Gujrat, Pakistan
15.1K vues21 diapositives
Boilers par
BoilersBoilers
BoilersDr. Rohit Singh Lather, Ph.D.
1.7K vues76 diapositives
performance analysis of steam boiler par
performance analysis of steam boilerperformance analysis of steam boiler
performance analysis of steam boilersathish sak
1.5K vues20 diapositives
Kota super thermal power plant,kstps ppt,RTU par
Kota super thermal power plant,kstps ppt,RTUKota super thermal power plant,kstps ppt,RTU
Kota super thermal power plant,kstps ppt,RTUManohar Nagar
2.9K vues23 diapositives
Thermal Plant report (Mechanical) par
Thermal Plant report (Mechanical)Thermal Plant report (Mechanical)
Thermal Plant report (Mechanical)sometech
1.4K vues27 diapositives
Unit 4 cogeneration par
Unit 4 cogenerationUnit 4 cogeneration
Unit 4 cogenerationprakash0712
1.1K vues52 diapositives

Tendances(20)

performance analysis of steam boiler par sathish sak
performance analysis of steam boilerperformance analysis of steam boiler
performance analysis of steam boiler
sathish sak1.5K vues
Kota super thermal power plant,kstps ppt,RTU par Manohar Nagar
Kota super thermal power plant,kstps ppt,RTUKota super thermal power plant,kstps ppt,RTU
Kota super thermal power plant,kstps ppt,RTU
Manohar Nagar2.9K vues
Thermal Plant report (Mechanical) par sometech
Thermal Plant report (Mechanical)Thermal Plant report (Mechanical)
Thermal Plant report (Mechanical)
sometech1.4K vues
Unit 4 cogeneration par prakash0712
Unit 4 cogenerationUnit 4 cogeneration
Unit 4 cogeneration
prakash07121.1K vues
High pressure boilers par MAHESH POL
High pressure boilersHigh pressure boilers
High pressure boilers
MAHESH POL203 vues
A Study of Boiler Efficiency par Ethan Grabill
A Study of Boiler EfficiencyA Study of Boiler Efficiency
A Study of Boiler Efficiency
Ethan Grabill1.7K vues
Boiler(Introduction,classification and it's types) by sujan kharel par ansaluniversity3
Boiler(Introduction,classification and it's types) by sujan kharelBoiler(Introduction,classification and it's types) by sujan kharel
Boiler(Introduction,classification and it's types) by sujan kharel
ansaluniversity329.4K vues
Rankine cycle par Akash Sood
Rankine cycleRankine cycle
Rankine cycle
Akash Sood43.7K vues
Boilers and its types & components par Yoga Sathish
Boilers and its types & componentsBoilers and its types & components
Boilers and its types & components
Yoga Sathish13.1K vues
Co-generation and trigeneration by Varun Pratap Singh par Varun Pratap Singh
Co-generation and trigeneration by Varun Pratap SinghCo-generation and trigeneration by Varun Pratap Singh
Co-generation and trigeneration by Varun Pratap Singh
Varun Pratap Singh4.7K vues

Similaire à Boiler lecture 29 JULY.pptx

Energy conservation boiler par
Energy conservation boilerEnergy conservation boiler
Energy conservation boilerMANJUNATH N
10.2K vues52 diapositives
Fossil Fuel Steam Generator (Thermal Power Plant) par
Fossil Fuel Steam Generator (Thermal Power Plant)Fossil Fuel Steam Generator (Thermal Power Plant)
Fossil Fuel Steam Generator (Thermal Power Plant)Hashim Hasnain Hadi
113 vues12 diapositives
fuel cycles.pptx par
fuel cycles.pptxfuel cycles.pptx
fuel cycles.pptxManikSharma33125
7 vues50 diapositives
CH 514 Geothermal.pptx par
CH 514 Geothermal.pptxCH 514 Geothermal.pptx
CH 514 Geothermal.pptxMUHAMMADUSAMA16272
23 vues40 diapositives
Fuel and combustion par
Fuel and combustionFuel and combustion
Fuel and combustionRaju Mirdha
20.8K vues100 diapositives
FM 3.pptx par
FM 3.pptxFM 3.pptx
FM 3.pptxKiranMayiAudina
4 vues40 diapositives

Similaire à Boiler lecture 29 JULY.pptx(20)

Energy conservation boiler par MANJUNATH N
Energy conservation boilerEnergy conservation boiler
Energy conservation boiler
MANJUNATH N10.2K vues
Fuel and combustion par Raju Mirdha
Fuel and combustionFuel and combustion
Fuel and combustion
Raju Mirdha20.8K vues
COAL BASED THERMAL POWER PLANTS (UNIT-1).pptx par CHANDRA KUMAR S
COAL BASED THERMAL POWER PLANTS (UNIT-1).pptxCOAL BASED THERMAL POWER PLANTS (UNIT-1).pptx
COAL BASED THERMAL POWER PLANTS (UNIT-1).pptx
CHANDRA KUMAR S28 vues
Generation of electricity from coal vol 1 par Sunil9009
Generation of electricity from coal vol 1Generation of electricity from coal vol 1
Generation of electricity from coal vol 1
Sunil9009908 vues
Cogeneration par GM Red
CogenerationCogeneration
Cogeneration
GM Red35 vues
Presentation on Boiler par Student
Presentation on BoilerPresentation on Boiler
Presentation on Boiler
Student23 vues
Boiler and steam system seminar short version 05 29-13 par Payden Sewell
Boiler and steam system seminar short version 05 29-13Boiler and steam system seminar short version 05 29-13
Boiler and steam system seminar short version 05 29-13
Payden Sewell4.1K vues

Dernier

Here comes the Loom - Ya!vaConf.pdf par
Here comes the Loom - Ya!vaConf.pdfHere comes the Loom - Ya!vaConf.pdf
Here comes the Loom - Ya!vaConf.pdfKrystian Zybała
7 vues134 diapositives
GPS Survery Presentation/ Slides par
GPS Survery Presentation/ SlidesGPS Survery Presentation/ Slides
GPS Survery Presentation/ SlidesOmarFarukEmon1
9 vues13 diapositives
Web Dev Session 1.pptx par
Web Dev Session 1.pptxWeb Dev Session 1.pptx
Web Dev Session 1.pptxVedVekhande
23 vues22 diapositives
Details of Acoustic Liner for selection of material par
Details of Acoustic Liner for selection of materialDetails of Acoustic Liner for selection of material
Details of Acoustic Liner for selection of materialrafiqalisyed
5 vues1 diapositive
PIT Interpretation - Use only PIT-W EN.ppt par
PIT Interpretation - Use only PIT-W EN.pptPIT Interpretation - Use only PIT-W EN.ppt
PIT Interpretation - Use only PIT-W EN.pptRabindra Shrestha
5 vues45 diapositives
Module-1, Chapter-2 Data Types, Variables, and Arrays par
Module-1, Chapter-2 Data Types, Variables, and ArraysModule-1, Chapter-2 Data Types, Variables, and Arrays
Module-1, Chapter-2 Data Types, Variables, and ArraysDemian Antony D'Mello
19 vues44 diapositives

Dernier(20)

Details of Acoustic Liner for selection of material par rafiqalisyed
Details of Acoustic Liner for selection of materialDetails of Acoustic Liner for selection of material
Details of Acoustic Liner for selection of material
rafiqalisyed5 vues
MongoDB.pdf par ArthyR3
MongoDB.pdfMongoDB.pdf
MongoDB.pdf
ArthyR353 vues
Programmable Switches for Programmable Logic Devices par Usha Mehta
Programmable Switches for Programmable Logic DevicesProgrammable Switches for Programmable Logic Devices
Programmable Switches for Programmable Logic Devices
Usha Mehta37 vues
AWS Certified Solutions Architect Associate Exam Guide_published .pdf par Kiran Kumar Malik
AWS Certified Solutions Architect Associate Exam Guide_published .pdfAWS Certified Solutions Architect Associate Exam Guide_published .pdf
AWS Certified Solutions Architect Associate Exam Guide_published .pdf
Field Programmable Gate Arrays : Architecture par Usha Mehta
Field Programmable Gate Arrays : ArchitectureField Programmable Gate Arrays : Architecture
Field Programmable Gate Arrays : Architecture
Usha Mehta33 vues
Design_Discover_Develop_Campaign.pptx par ShivanshSeth6
Design_Discover_Develop_Campaign.pptxDesign_Discover_Develop_Campaign.pptx
Design_Discover_Develop_Campaign.pptx
ShivanshSeth659 vues
REPORT Data Science EXPERT LECTURE.doc par Parulkhatri11
REPORT Data Science EXPERT LECTURE.docREPORT Data Science EXPERT LECTURE.doc
REPORT Data Science EXPERT LECTURE.doc
Parulkhatri117 vues
2023-12 Emarei MRI Tool Set E2I0501ST (TQ).pdf par Philipp Daum
2023-12 Emarei MRI Tool Set E2I0501ST (TQ).pdf2023-12 Emarei MRI Tool Set E2I0501ST (TQ).pdf
2023-12 Emarei MRI Tool Set E2I0501ST (TQ).pdf
Philipp Daum6 vues
BCIC - Manufacturing Conclave - Technology-Driven Manufacturing for Growth par Innomantra
BCIC - Manufacturing Conclave -  Technology-Driven Manufacturing for GrowthBCIC - Manufacturing Conclave -  Technology-Driven Manufacturing for Growth
BCIC - Manufacturing Conclave - Technology-Driven Manufacturing for Growth
Innomantra 28 vues
DevFest 2023 Daegu Speech_이재규, Implementing easy and simple chat with gol... par JQLEE6
DevFest 2023 Daegu Speech_이재규,  Implementing easy and simple chat with gol...DevFest 2023 Daegu Speech_이재규,  Implementing easy and simple chat with gol...
DevFest 2023 Daegu Speech_이재규, Implementing easy and simple chat with gol...
JQLEE616 vues
Different type of computer networks .pptx par nazmul1514788
Different  type of computer networks .pptxDifferent  type of computer networks .pptx
Different type of computer networks .pptx
nazmul151478820 vues

Boiler lecture 29 JULY.pptx

  • 1. The boiler as a steam generator.
  • 2. Steam Generators/Boilers • “A combination of apparatus for producing, furnishing or recovering heat together with apparatus for transferring the heat so made available to water which would be heated and vaporized to steam form” (ASME). • Basis for classification of boilers o Contents inside the tube o Firing system o Position of drum o Pressure o Nature of water circulation
  • 3. Water Tube and Fire Tube Boilers
  • 4. Requirements of a Good Boiler • Low cost of installation, operation and maintenance • Easy maintenance • High efficiency • Safety • High transportability • High steam production rate • Good quality of steam • Quick steam generation capacity • Meeting fluctuating demand of steam
  • 10. Boiler Accessories • Economiser • Air preheater • Super heater • Steam trap • Steam separator • Injector
  • 15. Boiler Performance Heat loss in the boiler Heat balance sheet
  • 17. • 1. Introduction, • 2. Equivalent Evaporation • 3. Boiler Efficiency. • 4. Boiler Trial • 5. Heat Losses in a boiler • 6. Heat balance sheet
  • 18. • Introduction • The performance of a steam boiler is measured in terms of its ‘evaporative capacity • In actual practice, the feed water temperature and working pressure varies considerably. • The feed temperature usually adopted is 100° C and the working pressure as normal atmospheric pressure, i.e. 1.013 bar. It is assumed that the boiler is supplied with water at the boiling temperature (100°C) corresponding to the atmospheric pressure.
  • 19. Equivalent evaporation • It is the amount of water evaporated from feed water at 100° C and formed into dry and saturated steam at 100° C at normal atmospheric pressure. It is, usually, written as “from and at 100 °C” • As the water is already at the boiling temperature. it requires only latent heat at 1.013 bar to convert it into steam at the temperature (100° C). The value of this latent heat is taken as 2257 kJ/kg. (hfg at 100°C)
  • 21. Equivalent evaporation E me = Kg/h or kg/kg of fuel burnt
  • 22. Is called the factor of evaporation Fe and is always greater than unity for all boilers. 𝐹𝑒 = ℎ − ℎ𝑓1 2257
  • 23. Boiler Efficiency • It may be defined as the ratio of heat actually used in producing the steam to the heat liberated in the furnace. It is also known as thermal efficiency of the boiler.
  • 24. Worked example • A boiler was used to produce wet steam at 11 bar with a dryness fraction of 0.8 from water at 12 C. Fuel is supplied to the furnace of the boiler at a rate of 325 kg per hour. The calorific value of the fuel is 35700 kJ/kg. The mass of water supplied to the boiler in 5 hrs 23 minutes = 15630 kg. • The mass of water was measured before and after the steam generation process and it was discovered that in order to restore the original level in the boiler 1200 kg of water was required. • Evaluate: • Actual evaporation per kilogram of coal • Equivalent evaporation from and at 100 C • Thermal efficiency of the boiler.
  • 25. Performance of Boilers • Evaporation Rate: It is steam generation rate of boilers which may be expressed in terms of kg of steam per unit heating surface area or kg of steam per cubic metre of furnace volume or kg of steam per kg fuel burnt. • Equivalent Evaporation: It is equivalent of energy of evaporation of 1 kg of water at 100°C to dry and saturated steam at 100°C, standard atmospheric pressure of 1.013 bar. Hence, the equivalent evaporation of 1 kg of water at 100°C needs 2,257 kJ. • Factor of Evaporation: It is ratio of heat absorbed by 1 kg of feed water under working conditions to latent heat of steam at atmospheric pressure.
  • 26. • Boiler Efficiency: It is ratio of heat absorbed by water in boiler to heat supplied to boiler per unit time.
  • 29. Worked example • A boiler was used to produce wet steam at 11 bar with a dryness fraction of 0.8 from water at 12 C. Fuel is supplied to the furnace of the boiler at a rate of 325 kg per hour. The calorific value of the fuel is 35700 kJ/kg. The mass of water supplied to the boiler in 5 hrs 23 minutes = 15630 kg. • The mass of water was measured before and after the steam generation process and it was discovered that in order to restore the original level in the boiler 1200 kg of water was required. • Evaluate: • Actual evaporation per kilogram of coal • Equivalent evaporation from and at 100 C • Thermal efficiency of the boiler.
  • 30. Boiler trial The main objectives of a boiler trial are: 1. To determine the generating capacity of the boiler. 2. To determine the thermal efficiency of the boiler when working at a definite pressure. 3. To prepare heat balance sheet for the boiler.
  • 31. Heat loss in a boiler • We know that the efficiency of a boiler is the ratio of heat utilised in producing steam to the heat liberated in the furnace. • The heat utilised is always less than the heat liberated in the furnace. • The difference of heat liberated in the furnace and heat utilised in producing steam is known as heat lost in the boiler.
  • 32. hf1 hf2 h3 = hf + x hfg h4 = hsup 1 2 3 4 Evaporator Economiser Superheater Steam Drum
  • 33. Heat lost to dry flue gases per kg of fuel
  • 34. Heat lost in moisture present in the fuel It is assumed that the moisture is converted into superheated steam at atmospheric pressure 1.013 bar). •Heat lost in moisture present in the fuel
  • 35. heat lost to steam formed by combustion of hydrogen per kg of fuel
  • 36. 4 The heat lost due to unburned carbon per kg of fuel
  • 37. Heat lost due to incomplete combustion of carbon to carbon monoxide. • This loss generally occurs in the boiler due to insufficient air supply.
  • 38. Heat lost due to radiation. • There is no direct method for finding the heat lost due to radiation. This loss is calculated subtracting the heat utilised in raising steam and heat losses from the heat supplied. • A Heat balance sheet shows the complete account of heat supplied by 1 kg of dry fuel and heat consumed. The heat supplied is mainly utilised for raising the steam and the remaining heat is lost.
  • 39. Heat balance sheet Heat supplied kJ Heat consumed kJ % Heat supplied by 1 kg of fuel Xf 1 Heat lost to dry flue gases per kg of fuel 2 Heat lost in moisture present in the fuel. 3 heat lost to steam formed by combustion of hydrogen per kg of fuel 4 The heat lost due to unburned carbon per kg of fuel 5. Heat lost due to incomplete combustion of carbon to carbon monoxide. 6. Heat lost due to radiation etc. X6 = Xf – (x1 + x2 + x3 + x4 + x5) X1 X2 X3 X4 X5 X6
  • 40. Example • In a boiler the following observations were made • Pressure of steam 10 bar • Steam condensed 540 kg/hr • Fuel used 65 kg/hr • Moisture in fuel 2% by mass • Mass of dry flue gas 9 kg/kg of fuel • Lower calorific value of fuel 32000 kJ/kg • Temperature of flue gases 325°C • Temperature of boiler house 28°C • Feed water temperature 50°C • Mean specific heat (flue gases) 1 kJ/kgK • Dryness fraction of steam 0.95 Draw up a heat balance sheet for the boiler
  • 41. • Heat supplied by 1 kg of fuel • =(1 - 0.02) x 32000 = 31360KJ • Heat utilised in raising steam per kg of fuel • From steam tables, for a feed water temp of 50°C • hf = 209.3 kJ/kg kg 31 . 8 65 540 m m me f s   
  • 42. • Correspondingly for steam at 10 bar • hf = 762.6 kJ/kg, hfg = 2013.6kJ/kg • Heat utilised in raising steam per kg of fuel • Heat carried away by dry flue gas     kJ t t c m b g pg g 2673 28 325 1 9              kJ h xh h m h h m f fg f e f f e 20495 3 . 209 6 . 2013 95 . 0 6 . 762 31 . 8 1 1 2            
  • 43. • Heat carried away by moisture in fuel per kg of fuel • From tables @ 28°C, hb = 117.3 kJ/kg • Heat carried away by moisture in fuel         kJ h t c m b g p m 6 . 60 3 . 117 100 325 1 . 2 2676 02 . 0 100 2676           Cp for steam = 2.1 kJ/kgK
  • 44. Heat balance sheet Heat supplied kJ Heat consumed kJ % Heat supplied by 1 kg of fuel 31360 1 Heat utilised in raising steam 2 Heat carried away by flue gases. 3 Heat lost in moisture present in the fuel. 4. Heat lost due to radiation etc. X6 = Xf – (x1 + x2 + x3) 20495 2673 60.6 = 8131.4 Totals 31360 31360
  • 45. The following particulars were recorded during a steam boiler trial Pressure of steam = 11 bar; mass of feed water = 4600 kg/hr; Temperature of feed water = 75C; dryness fraction of steam = 0.96; coal used 490 kg/hr; calorific value of coal 35700 kJ/kg; Moisture in coal 4% by mass; Mass of hydrogen in fuel 18% by mass mass of flue gases 18.57 kg/kg coal; temperature of flue gases = 300C; Boiler house temperature = 16C; specific heat of flue gases = 0.97 kJ/kg K Draw the heat balance sheet of the boiler per kg of
  • 46. In a boiler trial, the following observations were obtained. Pressure of steam = 8.5 bar; mass of feed water = 1520 kg/hr; Temperature of feed water = 30C; dryness fraction of steam = 0.95; coal used 200 kg/hr; Ash and unburnt coal collected = 16 kg/hr Calorific value of ash and unburnt coal = 3780 kJ/kg calorific value of coal 27300 kJ/kg; Moisture in coal 4% by mass; mass of flue gases 17.3 kg/kg coal; temperature of flue gases = 330C; Boiler house temperature = 17C; specific heat of flue gases = 1 kJ/kg K Draw the heat balance sheet of the boiler per kg of coal.
  • 48. Heat balance sheet Heat supplied kJ Heat consumed kJ % Heat supplied by 1 kg of (dry) fuel (1-%m)CV 1 Heat utilised in raising steam per kg of steam 𝑚𝑒 ℎ𝑓 + 𝑥ℎ𝑓𝑔 − ℎ𝑓1 2 Heat carried away by flue gases. 𝑚𝑔𝐶𝑝𝑔 𝑡𝑔 − 𝑡𝑏 3 Heat lost in moisture present in the fuel. 𝑚𝑚 ℎ𝑔 + 𝐶𝑝𝑠 𝑡𝑔 − 100 − ℎ𝑏 4 Heat lost in water formed from hydrogen present in the fuel. 𝑚𝐻𝑦𝑑𝑟𝑜𝑔𝑒𝑛 ℎ𝑔 + 𝐶𝑝𝑠 𝑡𝑔 − 100 − ℎ𝑏 4. Heat lost due to radiation etc. X6 = Xf – (x1 + x2 +x3 +x4) Totals