1. SMS Mobile Alert (GSM TECHNOLOGY) PLC Features
PLC Based
? Control System Make - Allen Bradley
Setting Parameters
PC Communication
? Via Ethernet
Set Master Temperature / Humidity
PLC Based
? Scanner System
Change Master / Scanner Print Frequency
Network Connection via Ethernet PLC Based
? Safety Control System to Protect the Chambers from Overshoot and Undershoot
Set Safety Temperature Higher / Lower Cut Off (°CHC1, °CHC2, °CLC1, °CLC2)
of Temperature and Humidity
Set Safety Humidity Higher / Lower Cut Off (%RH HC1, %RH HC2, %RH Lc1)
Auto Changeover
? of Master Sensor In Case of Failure
Auto Switch
? Over of Refrigeration System in Case of Failure
Safety Cut Off Details
Auto Change
? Over of Steam Generator in Case of Failure
Temperature Higher Cut Off ON / OFF
? Monitoring
Online on Graphic LCD 3.8" Touch Screen Display
Temperature Lower Cut Off ON / OFF
? for
Alarm Low Water Level with Reset System to Protect Steam Generator System.
Humidity Higher Cut Off ON / OFF
Password
? Protected Door Opening with Reason Master.
Humidity Lower Cut Off ON / OFF
Password
? Protected Chamber On / Off.
Setting Parameters
PLC System Password
? Protected Set Value Change
Crucial Controls
Password
? Protected Settable Print Frequency F or Master & Scanner
Power ON / OFF
? Password
? Protected Restore Factory Setting
Equipment Switch ON / OFF
Snooze
? Hooter System.
Cooling ON / OFF
?Logger
Event Facility.
Humidity ON / OFF
? Status
Actual Monitoring of Major Utilities (Sensor, Ref System, Steam Generation).
Heating ON / OFF
GSM Alarm
? System (Mobile Alert).
Door OPEN / CLOSE
PLC Based Password Protected Door Access System With Reason Master:
Safety Cut Off Details Events
The door access system grant permission based on password entered.
Steam Generator A FAILURE / OK
When access is granted, the door is unlocked for a predetermined time.
Steam Generator B FAILURE / OK
Touch Screen Display This transaction is recorded through DAAS software with a reason given by user.
High Temperature Thermostat ON / OFF
This record will reflect in Event Audit Trail with Date Time stamp.
Compressor Auto / Manual Mode Setting Change
Change Compressor Cycle Time Changeover
PLC Based Auto changeover Master Sensor In Case Of Failure:
Steam Generator Changeover Time Delay
Sensor measures temperature and relative humidity.
When controlling sensor fails, it automatically switches over to stand by sensor.
Crucial Controls
Password Based Door Access System
Events
For information log on: www.mackpharmatech.com Auto changeover Master Sensor For information log on: www.mackpharmatech.com