Personal breathing zone exposure monitoring
and surface contamination study of Lead at an
indoor firing range
Prasa...
#aihce
AGENDA
Background on indoor firing range
Test Environment and Activity
Methods and Evaluation criteria
Results ...
#aihce
Background
Indoor firing ranges used for
Shooting practice (Person inside firing range)
Testing Kevlar material ...
#aihce
Lead vaporized due to heat and pressure
within the cartridge (at the firing instance).
The heat of the reaction an...
#aihce
Test Environment and Activity
Indoor firing range had:
Heating and Ventilated Air Circulation (HVAC) system
(2 su...
#aihce
Operator used apron and single pair of Nitrile
gloves
Test centre cleaned daily with dry mop
followed by wet mop.
#aihce
Objective of study
To identify eight-hour/full shift personal
breathing zone exposure to lead particulates for
ope...
#aihce
Method and Sampling Strategy
Air sampling
 Three samples collected using Modified NIOSH 7300;
Inductively Coupled ...
#aihce
Wipe sampling
 Modified NIOSH 9102 (ICP-AES)
 Sampling media: Moistened Lead Dust sampling wipe
 Wipe samples co...
#aihce
Evaluation Criteria
Air samples
 Eight-Hour Time Weighted Average (TWA) exposure
compared with ACGIH TLV-TWA of 0....
#aihce
Results and observations
Range of Personal Breathing Zone exposure – 1.0
µg/m3 to 1.7 µg/m3
Exposure varies:
Bas...
#aihce
Lessons Learnt
Employee exposure, without regard to use of
respirator was below 10% of ACGIH TLV-TWA.
The surface...
#aihce
Recommendations
Clean all surfaces effectively with the use of a
High Efficiency Particulate Air (HEPA) filter
vac...
#aihce
References
• Indoor Firing Ranges Industrial Hygiene
Technical Guide (Navy Environmental Health Center)
#aihce
Thank You!
Any questions ?
Prasanth K.
Prasanth.k@issehs.com
#aihce
Vous avez terminé ce document.
Télécharger et lire hors ligne.
Prochain SlideShare
What to Upload to SlideShare
Suivant
Prochain SlideShare
What to Upload to SlideShare
Suivant
Télécharger pour lire hors ligne et voir en mode plein écran

0

Partager

Aih ce 2015 ppt pbz monitoing and wipe sampling for lead

Télécharger pour lire hors ligne

Aih ce 2015 ppt pbz monitoing and wipe sampling for lead

Livres associés

Gratuit avec un essai de 30 jours de Scribd

Tout voir

Livres audio associés

Gratuit avec un essai de 30 jours de Scribd

Tout voir
  • Soyez le premier à aimer ceci

Aih ce 2015 ppt pbz monitoing and wipe sampling for lead

  1. 1. #aihce Personal breathing zone exposure monitoring and surface contamination study of Lead at an indoor firing range Prasanth.K, Deputy Project Manager, India International Safety Systems, Inc. (ISS), India
  2. 2. #aihce AGENDA Background on indoor firing range Test Environment and Activity Methods and Evaluation criteria Results and Observations Lessons Learned Recommendations
  3. 3. #aihce Background Indoor firing ranges used for Shooting practice (Person inside firing range) Testing Kevlar material (Person can be outside) Potential Hazards (Noise and Lead) Bullets are loaded with gunpowder and have Lead based primer.
  4. 4. #aihce Lead vaporized due to heat and pressure within the cartridge (at the firing instance). The heat of the reaction and cooling results in formation of lead particles at Source Bullet trap Path way
  5. 5. #aihce Test Environment and Activity Indoor firing range had: Heating and Ventilated Air Circulation (HVAC) system (2 supply ducts from top and 4 return ducts from side walls) with 20 air changes per hour Acoustic enclosure Bullet traps Operator places Kevlar material at test stand and loads the barrel with bullet and trigger is pulled from outside the room.
  6. 6. #aihce Operator used apron and single pair of Nitrile gloves Test centre cleaned daily with dry mop followed by wet mop.
  7. 7. #aihce Objective of study To identify eight-hour/full shift personal breathing zone exposure to lead particulates for operator testing the kevlar by firing bullets in an Indoor firing range. To evaluate the level of surface contamination due to the deposition of lead particulates.
  8. 8. #aihce Method and Sampling Strategy Air sampling  Three samples collected using Modified NIOSH 7300; Inductively Coupled Argon Plasma-Atomic Emission Spectrometry (ICP-AES)  Sampling media: 37mm Matched Weight (MW) Mixed Cellulose Ester (MCE) filter  Sampling flow rate: 4 litres/minute  Sampling duration: 7 hours. (Not sampled during lunch break)  Two filters used for 3.5 hours each to avoid overloading of particulates on filter.
  9. 9. #aihce Wipe sampling  Modified NIOSH 9102 (ICP-AES)  Sampling media: Moistened Lead Dust sampling wipe  Wipe samples collected before start of the activity (beginning of shift) after completion of activity (end of shift)  Wipe samples collected at 11 locations over an area of 100 cm2
  10. 10. #aihce Evaluation Criteria Air samples  Eight-Hour Time Weighted Average (TWA) exposure compared with ACGIH TLV-TWA of 0.05 mg/m3 (50 μg/m3) Wipe samples  OSHA guideline for a level of acceptable lead loading for non-lead work areas of 0.2 μg/cm2. (Legally not applicable).
  11. 11. #aihce Results and observations Range of Personal Breathing Zone exposure – 1.0 µg/m3 to 1.7 µg/m3 Exposure varies: Based on the number of bullets fired. Duration of person inside the firing range. Wipe samples results at beginning of shift - 0.02 µg/cm2 to 4.1 µg/cm2 Wipe samples results at end of shift – 0.13 µg/cm2 to 38 µg/cm2
  12. 12. #aihce Lessons Learnt Employee exposure, without regard to use of respirator was below 10% of ACGIH TLV-TWA. The surface contamination level increased by 10 folds, after firing of bullets. Potential for ingestion risk exists due to surface contamination.
  13. 13. #aihce Recommendations Clean all surfaces effectively with the use of a High Efficiency Particulate Air (HEPA) filter vacuum cleaner. Use dual pair of disposable nitrile gloves before contacting potential contaminated surfaces. Remove the outer pair of gloves after it is contaminated. Avoid touching of door handles with contaminated gloves
  14. 14. #aihce References • Indoor Firing Ranges Industrial Hygiene Technical Guide (Navy Environmental Health Center)
  15. 15. #aihce Thank You! Any questions ? Prasanth K. Prasanth.k@issehs.com
  16. 16. #aihce

Aih ce 2015 ppt pbz monitoing and wipe sampling for lead

Vues

Nombre de vues

172

Sur Slideshare

0

À partir des intégrations

0

Nombre d'intégrations

118

Actions

Téléchargements

2

Partages

0

Commentaires

0

Mentions J'aime

0

×