Azbil MVF Series Micro Flow vortex gas flowmeters provide high sensitivity and quick response through the use of proprietary sensor technology. Temperature and pressure compensation are built in, negating the need for two additional devices.
1. The MVF series of Micro Flow vortex gas flowmeters make use of
our proprietary μF (Micro Flow) sensor, which has high sensitivity
and quick response. As a result, MVF flowmeters achieve a wide
measurement range of 100:1.
In addition, a temperature and pressure compensation function is built
in, so there is no need for a temperature sensor, pressure sensor, or
compensation device, contributing to the reduction in total cost.
Model No. configuration Ex.: MVF0500CUN0110000
Basic
model No.
MVF
Gas type
N
S
C
G
P
B
Connection
U
D
A
Power
supply
1
Communi-
cation
1
Output
0
Pipe size
050
080
100
150
Micro Flow vortex gas flowmeter
50 A (2B)
80 A (3B)
100 A (4B)
150 A (6B)
With temperature & pressure compensation
Without pressure compensation, with temperature compensation
Low pressure range (0 to 0.1 Mpa),
with temperature & pressure compensation
Medium pressure range (0 to 0.3 Mpa),
with temperature & pressure compensation
Main unit material SCS13A
Wafer connection (with spacer for JIS 10K flange)
Wafer connection (with spacer for DIN PN10 flange)
Wafer connection (with spacer for ANSI 150 flange)
Air/nitrogen, argon
Oxygen (degreasing must be selected)*1
Carbon dioxide gas
City gas 13 A (LNG base), methane
Propane
Butane
With 4 to 20 mA output + pulse output
24 Vdc power supply
RS-485 communication
Horizontal left to right flow, converter on top*2
Horizontal left to right flow, converter on bottom*2
Horizontal right to left flow, converter on top*2
Horizontal right to left flow, converter on bottom*2
Vertical below to above flow, converter on left*2
Vertical above to below flow, converter on left*2
None
Degreasing of gas-contacting parts (necessary if fluid is oxygen)*1
None
Mill sheet for main unit and vortex generator
Product version
Model
0
L
1
3
Material
C
DescriptionDirection
0
1
2
3
4
5
Option 1
0
1
Option 2
0
C
Appended
No.
0
*1. If oxygen (“S”) is selected, be sure to select “1” (Degreasing of gas-contacting parts) for Option 1.
*2. Explanation of flow direction
Specifications
Model No.
Pipe size
Gas types
Operating temperature range
Operating pressure range,
pressure sensor accuracy
Rated power supply voltage
Output signal (1)
Integrated pulse output (1)
Communication function
Gas-contacting material
Connection type
Pipe size
Protective structure
Weight
MVF050 MVF080 MVF100 MVF150
50 A 80 A 100 A 150 A
Air, nitrogen, argon, oxygen, carbon dioxide (CO2), city gas (13 A), methane, propane, butane, and other inert gases and mixed gases outside the explosion limit range
-15 to +60 °C
Model No.: MVF 1C 011 00: 0.0–0.1 MPa, ±2% FS @23 °C
Model No.: MVF 3C 011 00: 0.0–0.3 MPa, ±2% FS @23 °C
Model No.: MVF 0C 011 00: 0.0–1.0 MPa, ±1% FS @23 °C
24 Vdc. Operating range: 24 Vdc±10%, 100 mA or less
Instantaneous flow rate output: 4 to 20 mAdc (allowable load resistance 600 Ω max.), maximum current: 23.2 mA, approx. 3.5 mA downscale output during burnout
Open collector output, contact rating: 10 to 30 Vdc, 20 mA or less, pulse weight: selectable from 0.1, 1, and 10 m3
/pulse
RS-485 interface, 3-wire system
Flow passage: SCS13A, SUS304. μF sensor: silicon, gold, etc. O-ring: type 4D (Viton).
JIS 10K wafer connection
50 A (2B) 80 A (3B) 100 A (4B) 150 A (6B)
IP67 (by JIS C 0920 and IEC 529 standards, watertight structure for the assumed outdoor installation)
6.3 kg 6.6 kg 9 kg 17 kg
Left to right flow Flow direction: below to above Right to left flow Flow direction: above to below
Converter is above
Code 0
Converter is below
Code 1
Converter is on the left
Code 4
Converter is above
Code 2
Converter is below
Code 3
Converter is on the left
Code 5
[Explanation of terms] % rdg: percentage of the reading. m3
/h (normal): indicates a value converted to volumetric flow per hour at 0 °C and 101.325 kPa (1 atmosphere).
Specification method
(1) 4 to 20 mA span
After checking the measurement range for each pressure,
specify the model.
Maximum span specifications m3
/h (normal)
(2) Pulse weight
50 A: 0.01, 0.1, 1, 10 m3
/pulse
Other than 50 A: select from 0.1, 1, 10, and 100 m3
/pulse.
Sample specification
Model No. MVF0800CUN0112000
Range 0 to 500 m3
/h (normal)
Pulse weight 1 m3
/pulse
50 A
80 A
100 A
150 A
8000 m3
/h (normal)
16000 m3
/h (normal)
24000 m3
/h (normal)
48000 m3
/h (normal)
The minimum span specification is 1% of the maximum span
specification.