4. THDPM-1
THDPM-1
•- Measures all AC
parameters and THD
upto 55th harmonics
•- Reads all SMART-QC
data using RS485 port at
back
-Easily configurable
limits for Pass/Fail status
Pass/Fail
LED
5. Variac and Auto volt
switcher
Variac –
We are using two variacs for
170V and 250V.
Auto Volt Switcher-
It is a programmable switching
device. Four Buttons enable
output in any one of 4 modes:
1. Relay1-170 volt
2. Relay2-250 volt
3. Zero output
4. Auto mode- in this mode it
provides zero volt, 170V and
250V for 5 sec each.
The objective here is to check
and store all readings at two
different voltage inputs.
6. Software
Software-
-It is easy to configure limits.
-It automatically detects the
test mode from Volt-switcher.
- You can save in csv data on
two/three different voltage
levels on a single button.
7. Total testing time is one
min per SMPS/LED Driver
Connection time 25sec
Press the button 05sec
Measurement time 20sec
Checking OK 10sec
Total Time 60sec