Publicité
The simplified heat balance diagram of a real coal fired power plant i.docx
The simplified heat balance diagram of a real coal fired power plant i.docx
Prochain SlideShare
Jean-Paul Gibson:  Analysis Of An Open Feedwater Heater SystemJean-Paul Gibson: Analysis Of An Open Feedwater Heater System
Chargement dans ... 3
1 sur 2
Publicité

Contenu connexe

Plus de helenc18(20)

Publicité

The simplified heat balance diagram of a real coal fired power plant i.docx

  1. The simplified heat balance diagram of a real coal fired power plant is given bellow. What is the power output of the plant? The power plant is to undergo solar modification using Solar Aided Power Generation (SAPG) technology. There are two solar modification plans: a) solar concentration collectors are used to generate solar heat to replace extraction steam A b) Simple solar collectors are used to generate solar heat to replace extraction steam F only. What is the minimum solar fluid temperature (out of the collectors) required for plan a) and b), respectively, if the minimum temperature difference required in heat exchanger is 5oC? Solution Power output of turbine = 3400.3*407.71 - 3058.5*407.71 + 3531.9*363.105 - 3031.5*318.529 - 3299.6*24.832 - 3031.5*21.206 + 3031.5*318.529 - 2396.9*277.709 - 2561.1*18.487 - 2458.4*6.744 - 2818.2*16.045 = 500798.933 power consumed by pump = 189.9*285.36 - 187.6*285.36 +