Design And Analysis of Different Artificial Human Hip Stems Based on Fenestrations Using PEEK Material
Signaler
Partager
IRJET Journal
Fast Track Publications
Suivre
•
0 j'aime
•
28 vues
Ingénierie
https://www.irjet.net/archives/V10/i8/IRJET-V10I847.pdf
Lire la suite
Design And Analysis of Different Artificial Human Hip Stems Based on Fenestrations Using PEEK Material
•
0 j'aime
•
28 vues
IRJET Journal
Fast Track Publications
Suivre
Signaler
Partager
Ingénierie
https://www.irjet.net/archives/V10/i8/IRJET-V10I847.pdf
Lire la suite
Design And Analysis of Different Artificial Human Hip Stems Based on Fenestrations Using PEEK Material
1 sur 8
Télécharger maintenant
Recommandé
FINITE ELEMENT ANALYSIS OF FEMORAL INTRAMEDULLARY NAILING par
FINITE ELEMENT ANALYSIS OF FEMORAL INTRAMEDULLARY NAILING
Journal For Research
369 vues
•
8 diapositives
Modelling and static analysis of femur bone by using different implant materials par
Modelling and static analysis of femur bone by using different implant materials
IOSR Journals
790 vues
•
10 diapositives
H1302034856 par
H1302034856
IOSR Journals
233 vues
•
9 diapositives
Total Hip Replacement Implant Designing and its Computational Analysis using ... par
Total Hip Replacement Implant Designing and its Computational Analysis using ...
IRJET Journal
6 vues
•
5 diapositives
Finite element stress analysis of artificial femur head on hip joint par
Finite element stress analysis of artificial femur head on hip joint
SAURABH SINGH
343 vues
•
18 diapositives
Biochmical1 pdf par
Biochmical1 pdf
Kiran Kumar
20 vues
•
74 diapositives
Contenu connexe
Similaire à Design And Analysis of Different Artificial Human Hip Stems Based on Fenestrations Using PEEK Material
Evolution of Total Hip Replacement par
Evolution of Total Hip Replacement
Tejasvi Agarwal
7.4K vues
•
50 diapositives
bone and_cartilage_tissue_engineering by Sumit par
bone and_cartilage_tissue_engineering by Sumit
Dcrust
511 vues
•
22 diapositives
Extremity_Wear_Testing_-_Total_Ankle_and_Shoulder_Replacement_Testing_ par
Extremity_Wear_Testing_-_Total_Ankle_and_Shoulder_Replacement_Testing_
Evan Guilfoyle
259 vues
•
7 diapositives
Review on alternative material for prostheesis.pdf par
Review on alternative material for prostheesis.pdf
Endalkachew Gashawtena
7 vues
•
6 diapositives
Review on-alternate-materials-for-producing-low-cost-lower-limb-prosthetic-so... par
Review on-alternate-materials-for-producing-low-cost-lower-limb-prosthetic-so...
Endalkachew Gashawtena
81 vues
•
6 diapositives
Review on-alternate-materials-for-producing-low-cost-lower-limb-prosthetic-so... par
Review on-alternate-materials-for-producing-low-cost-lower-limb-prosthetic-so...
Endalkachew Gashawtena
74 vues
•
6 diapositives
Similaire à Design And Analysis of Different Artificial Human Hip Stems Based on Fenestrations Using PEEK Material
(20)
Evolution of Total Hip Replacement par Tejasvi Agarwal
Evolution of Total Hip Replacement
Tejasvi Agarwal
•
7.4K vues
bone and_cartilage_tissue_engineering by Sumit par Dcrust
bone and_cartilage_tissue_engineering by Sumit
Dcrust
•
511 vues
Extremity_Wear_Testing_-_Total_Ankle_and_Shoulder_Replacement_Testing_ par Evan Guilfoyle
Extremity_Wear_Testing_-_Total_Ankle_and_Shoulder_Replacement_Testing_
Evan Guilfoyle
•
259 vues
Review on alternative material for prostheesis.pdf par Endalkachew Gashawtena
Review on alternative material for prostheesis.pdf
Endalkachew Gashawtena
•
7 vues
Review on-alternate-materials-for-producing-low-cost-lower-limb-prosthetic-so... par Endalkachew Gashawtena
Review on-alternate-materials-for-producing-low-cost-lower-limb-prosthetic-so...
Endalkachew Gashawtena
•
81 vues
Review on-alternate-materials-for-producing-low-cost-lower-limb-prosthetic-so... par Endalkachew Gashawtena
Review on-alternate-materials-for-producing-low-cost-lower-limb-prosthetic-so...
Endalkachew Gashawtena
•
74 vues
Prosthetic Body Parts par IshwarJadhav4
Prosthetic Body Parts
IshwarJadhav4
•
593 vues
Immediate loading par Mohammed Alshehri
Immediate loading
Mohammed Alshehri
•
19.5K vues
Finite Element Investigation of Hybrid and Conventional Knee Implants par CSCJournals
Finite Element Investigation of Hybrid and Conventional Knee Implants
CSCJournals
•
389 vues
Bone Grafts /certified fixed orthodontic courses by Indian dental academy par Indian dental academy
Bone Grafts /certified fixed orthodontic courses by Indian dental academy
Indian dental academy
•
7.9K vues
Butler_0916 par Terry Butler
Butler_0916
Terry Butler
•
145 vues
Avinash bioscrew par Dr.Avinash Rao Gundavarapu
Avinash bioscrew
Dr.Avinash Rao Gundavarapu
•
118 vues
Orthopedic implants.pptx par tumainimatandala1
Orthopedic implants.pptx
tumainimatandala1
•
31 vues
Fatigue Analysis of a Bone Implant Construct par Mert G
Fatigue Analysis of a Bone Implant Construct
Mert G
•
882 vues
Biomaterials in use par Ashish Kumar Gouda
Biomaterials in use
Ashish Kumar Gouda
•
1K vues
Phd paper plain par DrMohamed Assadawy
Phd paper plain
DrMohamed Assadawy
•
172 vues
Bone grafts and Bone Substitutes/ dental implant courses par Indian dental academy
Bone grafts and Bone Substitutes/ dental implant courses
Indian dental academy
•
4.5K vues
Strontium-Coated Clay Nanoparticles in Calcium Phosphate Cement for Biomedica... par AnushaElumalai
Strontium-Coated Clay Nanoparticles in Calcium Phosphate Cement for Biomedica...
AnushaElumalai
•
84 vues
Orthopedic implants par haleeful jud
Orthopedic implants
haleeful jud
•
589 vues
Additive Manufacturing and Testing of a Prosthetic Foot Ankle Joint par ijtsrd
Additive Manufacturing and Testing of a Prosthetic Foot Ankle Joint
ijtsrd
•
337 vues
Plus de IRJET Journal
SOIL STABILIZATION USING WASTE FIBER MATERIAL par
SOIL STABILIZATION USING WASTE FIBER MATERIAL
IRJET Journal
20 vues
•
7 diapositives
Sol-gel auto-combustion produced gamma irradiated Ni1-xCdxFe2O4 nanoparticles... par
Sol-gel auto-combustion produced gamma irradiated Ni1-xCdxFe2O4 nanoparticles...
IRJET Journal
8 vues
•
7 diapositives
Identification, Discrimination and Classification of Cotton Crop by Using Mul... par
Identification, Discrimination and Classification of Cotton Crop by Using Mul...
IRJET Journal
7 vues
•
5 diapositives
“Analysis of GDP, Unemployment and Inflation rates using mathematical formula... par
“Analysis of GDP, Unemployment and Inflation rates using mathematical formula...
IRJET Journal
13 vues
•
11 diapositives
MAXIMUM POWER POINT TRACKING BASED PHOTO VOLTAIC SYSTEM FOR SMART GRID INTEGR... par
MAXIMUM POWER POINT TRACKING BASED PHOTO VOLTAIC SYSTEM FOR SMART GRID INTEGR...
IRJET Journal
14 vues
•
6 diapositives
Performance Analysis of Aerodynamic Design for Wind Turbine Blade par
Performance Analysis of Aerodynamic Design for Wind Turbine Blade
IRJET Journal
7 vues
•
5 diapositives
Plus de IRJET Journal
(20)
SOIL STABILIZATION USING WASTE FIBER MATERIAL par IRJET Journal
SOIL STABILIZATION USING WASTE FIBER MATERIAL
IRJET Journal
•
20 vues
Sol-gel auto-combustion produced gamma irradiated Ni1-xCdxFe2O4 nanoparticles... par IRJET Journal
Sol-gel auto-combustion produced gamma irradiated Ni1-xCdxFe2O4 nanoparticles...
IRJET Journal
•
8 vues
Identification, Discrimination and Classification of Cotton Crop by Using Mul... par IRJET Journal
Identification, Discrimination and Classification of Cotton Crop by Using Mul...
IRJET Journal
•
7 vues
“Analysis of GDP, Unemployment and Inflation rates using mathematical formula... par IRJET Journal
“Analysis of GDP, Unemployment and Inflation rates using mathematical formula...
IRJET Journal
•
13 vues
MAXIMUM POWER POINT TRACKING BASED PHOTO VOLTAIC SYSTEM FOR SMART GRID INTEGR... par IRJET Journal
MAXIMUM POWER POINT TRACKING BASED PHOTO VOLTAIC SYSTEM FOR SMART GRID INTEGR...
IRJET Journal
•
14 vues
Performance Analysis of Aerodynamic Design for Wind Turbine Blade par IRJET Journal
Performance Analysis of Aerodynamic Design for Wind Turbine Blade
IRJET Journal
•
7 vues
Heart Failure Prediction using Different Machine Learning Techniques par IRJET Journal
Heart Failure Prediction using Different Machine Learning Techniques
IRJET Journal
•
7 vues
Experimental Investigation of Solar Hot Case Based on Photovoltaic Panel par IRJET Journal
Experimental Investigation of Solar Hot Case Based on Photovoltaic Panel
IRJET Journal
•
3 vues
Metro Development and Pedestrian Concerns par IRJET Journal
Metro Development and Pedestrian Concerns
IRJET Journal
•
2 vues
Mapping the Crashworthiness Domains: Investigations Based on Scientometric An... par IRJET Journal
Mapping the Crashworthiness Domains: Investigations Based on Scientometric An...
IRJET Journal
•
3 vues
Data Analytics and Artificial Intelligence in Healthcare Industry par IRJET Journal
Data Analytics and Artificial Intelligence in Healthcare Industry
IRJET Journal
•
3 vues
DESIGN AND SIMULATION OF SOLAR BASED FAST CHARGING STATION FOR ELECTRIC VEHIC... par IRJET Journal
DESIGN AND SIMULATION OF SOLAR BASED FAST CHARGING STATION FOR ELECTRIC VEHIC...
IRJET Journal
•
44 vues
Efficient Design for Multi-story Building Using Pre-Fabricated Steel Structur... par IRJET Journal
Efficient Design for Multi-story Building Using Pre-Fabricated Steel Structur...
IRJET Journal
•
10 vues
Development of Effective Tomato Package for Post-Harvest Preservation par IRJET Journal
Development of Effective Tomato Package for Post-Harvest Preservation
IRJET Journal
•
4 vues
“DYNAMIC ANALYSIS OF GRAVITY RETAINING WALL WITH SOIL STRUCTURE INTERACTION” par IRJET Journal
“DYNAMIC ANALYSIS OF GRAVITY RETAINING WALL WITH SOIL STRUCTURE INTERACTION”
IRJET Journal
•
5 vues
Understanding the Nature of Consciousness with AI par IRJET Journal
Understanding the Nature of Consciousness with AI
IRJET Journal
•
12 vues
Augmented Reality App for Location based Exploration at JNTUK Kakinada par IRJET Journal
Augmented Reality App for Location based Exploration at JNTUK Kakinada
IRJET Journal
•
6 vues
Smart Traffic Congestion Control System: Leveraging Machine Learning for Urba... par IRJET Journal
Smart Traffic Congestion Control System: Leveraging Machine Learning for Urba...
IRJET Journal
•
18 vues
Enhancing Real Time Communication and Efficiency With Websocket par IRJET Journal
Enhancing Real Time Communication and Efficiency With Websocket
IRJET Journal
•
4 vues
Textile Industrial Wastewater Treatability Studies by Soil Aquifer Treatment ... par IRJET Journal
Textile Industrial Wastewater Treatability Studies by Soil Aquifer Treatment ...
IRJET Journal
•
4 vues
Dernier
Generative AI Models & Their Applications par
Generative AI Models & Their Applications
SN
6 vues
•
1 diapositive
Pull down shoulder press final report docx (1).pdf par
Pull down shoulder press final report docx (1).pdf
Comsat Universal Islamabad Wah Campus
12 vues
•
25 diapositives
Quality Manual Chaity Group.pdf par
Quality Manual Chaity Group.pdf
Mizan Rahman
5 vues
•
61 diapositives
Advances in micro milling: From tool fabrication to process outcomes par
Advances in micro milling: From tool fabrication to process outcomes
Shivendra Nandan
5 vues
•
18 diapositives
K8S Roadmap.pdf par
K8S Roadmap.pdf
MaryamTavakkoli2
6 vues
•
1 diapositive
Update 42 models(Diode/General ) in SPICE PARK(DEC2023) par
Update 42 models(Diode/General ) in SPICE PARK(DEC2023)
Tsuyoshi Horigome
23 vues
•
16 diapositives
Dernier
(20)
Generative AI Models & Their Applications par SN
Generative AI Models & Their Applications
SN
•
6 vues
Pull down shoulder press final report docx (1).pdf par Comsat Universal Islamabad Wah Campus
Pull down shoulder press final report docx (1).pdf
Comsat Universal Islamabad Wah Campus
•
12 vues
Quality Manual Chaity Group.pdf par Mizan Rahman
Quality Manual Chaity Group.pdf
Mizan Rahman
•
5 vues
Advances in micro milling: From tool fabrication to process outcomes par Shivendra Nandan
Advances in micro milling: From tool fabrication to process outcomes
Shivendra Nandan
•
5 vues
K8S Roadmap.pdf par MaryamTavakkoli2
K8S Roadmap.pdf
MaryamTavakkoli2
•
6 vues
Update 42 models(Diode/General ) in SPICE PARK(DEC2023) par Tsuyoshi Horigome
Update 42 models(Diode/General ) in SPICE PARK(DEC2023)
Tsuyoshi Horigome
•
23 vues
NEW SUPPLIERS SUPPLIES (copie).pdf par georgesradjou
NEW SUPPLIERS SUPPLIES (copie).pdf
georgesradjou
•
15 vues
An approach of ontology and knowledge base for railway maintenance par IJECEIAES
An approach of ontology and knowledge base for railway maintenance
IJECEIAES
•
12 vues
Stone Masonry and Brick Masonry.pdf par Mohammed Abdullah Laskar
Stone Masonry and Brick Masonry.pdf
Mohammed Abdullah Laskar
•
21 vues
DESIGN OF SPRINGS-UNIT4.pptx par gopinathcreddy
DESIGN OF SPRINGS-UNIT4.pptx
gopinathcreddy
•
19 vues
MK__Cert.pdf par Hassan Khan
MK__Cert.pdf
Hassan Khan
•
10 vues
Digital Watermarking Of Audio Signals.pptx par AyushJaiswal781174
Digital Watermarking Of Audio Signals.pptx
AyushJaiswal781174
•
11 vues
SUMIT SQL PROJECT SUPERSTORE 1.pptx par Sumit Jadhav
SUMIT SQL PROJECT SUPERSTORE 1.pptx
Sumit Jadhav
•
12 vues
MSA Website Slideshow (16).pdf par msaucla
MSA Website Slideshow (16).pdf
msaucla
•
64 vues
SPICE PARK DEC2023 (6,625 SPICE Models) par Tsuyoshi Horigome
SPICE PARK DEC2023 (6,625 SPICE Models)
Tsuyoshi Horigome
•
17 vues
Searching in Data Structure par raghavbirla63
Searching in Data Structure
raghavbirla63
•
5 vues
Thermal aware task assignment for multicore processors using genetic algorithm par IJECEIAES
Thermal aware task assignment for multicore processors using genetic algorithm
IJECEIAES
•
31 vues
What is Whirling Hygrometer.pdf par IIT KHARAGPUR
What is Whirling Hygrometer.pdf
IIT KHARAGPUR
•
11 vues
Effect of deep chemical mixing columns on properties of surrounding soft clay... par AltinKaradagli
Effect of deep chemical mixing columns on properties of surrounding soft clay...
AltinKaradagli
•
6 vues
Activated sludge process .pdf par 8832RafiyaAltaf
Activated sludge process .pdf
8832RafiyaAltaf
•
9 vues
Design And Analysis of Different Artificial Human Hip Stems Based on Fenestrations Using PEEK Material
1.
International Research Journal
of Engineering and Technology (IRJET) e-ISSN: 2395-0056 Volume: 10 Issue: 08 | Aug 2023 www.irjet.net p-ISSN: 2395-0072 © 2023, IRJET | Impact Factor value: 8.226 | ISO 9001:2008 Certified Journal | Page 276 Design And Analysis of Different Artificial Human Hip Stems Based on Fenestrations Using PEEK Material Mr. Rohith. N1, Dr. H. C. Chittappa2 1M. Tech Student, Department of Mechanical Engineering, University Visvesvaraya College of Engineering, Bangalore, Karnataka, India. 2Professor, Department of Mechanical Engineering, University Visvesvaraya College of Engineering, Bangalore, Karnataka, India. ---------------------------------------------------------------------***--------------------------------------------------------------------- Abstract - The Hip joint is a primary joint which provides stability to the human body. These joints will be replaced by the implants during hip replacement procedures due to wear and strain brought on by ageing and other factors. Hip joint prostheses are structural parts that still struggle with complex issues including the interaction of the hip stem's physical and biological characteristics with the human femur bone. On the commercial market, there are numerous varieties of artificial hip joints. The needs of the patients can be accommodated by choosing from a variety of materials and designs. One of them is the hip stem design with fenestrations. Titanium and stainless steel are the materials that are frequently utilised in hip joint replacement. The design and analysis of complete joint replacements and other orthopaedic devices have benefited from the use of the finite element approach in orthopaedic biomechanics. In this work, three different types of hip stems were considered viz., hip stem with out fenestration, hip stem with bigloop fenestration and hip stem with slot fenestration were modeled using SOLIDWORKS 2018 by Dassault Systems and these hip stems were analyzed for the stress– strain distribution and deformation over the hip stem prosthesis under different loading conditions like, standing, walking, jumping and running for this we used two different materials Polyether-ether-ketone (PEEK) and Ti-6Al-4V using renowned tool ANSYS Workbench 2022 R2 version to produce the hip stem with the best design and material available. Key Words: Finite Element Method, Biomaterials, Hip implant, Artificial hip joint, PEEK. 1. INTRODUCTION A biomaterial is a material that have been produced to interact with living systems for therapaeutic (treating, improving, fixing, or changing a tissue function of the body) either diagnostic purpose. Bio-materials has been a field of study for nearly 50 years. Bio-implants, which include porous bone implants, dental implants, prostheses, wearable biosensors, and drug delivery devices, are all implants used in medical or clinical therapy. Typically, they are placed within the body of a person for more than 30 days. They integrate with the human body, the qualities of materials, and the intactness of bio-implants to fix, sustain, recreate, either to improve the function of the human tissues. 1.1 Total Hip Replacement Hip joint replacement using artificial replacement surgery needs to be performed for patients with permanent hip joint damage due to, aging, necrosis, osteoarthritis, osteoporosis or accidents. Many patients with hip joint disease have difficulties carrying out for daily activities; thus, hip replacement surgery has become a standard method. THR is called as “Operation of Century” because it has revolutionised the treatment of a patient with advanced hip disorders. THR involves exchange of the morbid hip with a hip implant referred to as prosthesis, that is employed to transferring the load from socket to the leg bone by implanting a hip stem into the latter. Ideally, the stem area of a hip implant thought to be fully contact with the surrounding femure cortical bone to attain stable fixation during a THR. The hip implant is additionally responsible for getting the physiological load from the hip stem and transfers some amount of it to the surrounding tissues. These are the major surgical procedures, that are solely undertaken once the disease has proceeded to the stage where no different treatment is possible the aim is to alleviate pain and improve mobility [1]. Fig. 1 Steps of Total Hip Replacement surgery
2.
International Research Journal
of Engineering and Technology (IRJET) e-ISSN: 2395-0056 Volume: 10 Issue: 08 | Aug 2023 www.irjet.net p-ISSN: 2395-0072 © 2023, IRJET | Impact Factor value: 8.226 | ISO 9001:2008 Certified Journal | Page 277 2. LITERATURE REVIEW Solehuddin bin Shuib et al. Hip implants are prosthetic joints made of metals like titanium alloy or stainless steel. They are carried in place by lengthy stems that protrude deep into the femur canal. When a human hip joint withstands a biological injury, it is typically used. Analysis also reveals a yearly rise in the number of people who get this type of surgery, especially those who are older and fall into the 65+ age group. The objective of this study is to research hip implant advancements and to suggest a design that fully satisfies the requirements for designing a hip implant. Hip implants must take into consideration a variety of factors, including stiffness, implant characteristics, and implant size. Materials are among the most essential design considerations for a hip implant since they have a direct impact on the implant's stiffness. Titanium and stainless steel are the commonly used materials [2]. Kelechukwu Onuoha et al. The process of THR is eminent. By reducing pain and functional impairment, THR enhances the quality of life for persons with moderate to serious hip arthritis. In this analysis, only hip osteoarthritis patients were included. It was simple to identify osteoarthritis as an indication for the surgery because research also shown that arthritis was a common reason for THR. 71.4 % of the patients in this work were found to be older than 50 years [3]. Manuel Guzman et al. The femoral head and the hip stem are the two primary parts of the prosthesis utilized in THR. SS 316L, Ti alloys (Ti-6Al-4V and TMZF), and Co-Cr alloys are the most commonly utilized metal alloys for these components, despite the fact that they are prone to loose particles. These materials after implanted, plays a crucial role in the distribution of stress and strain because their high elasticity modulus which is greater than that of human bone. The requirements for a hip implant’s design are complicated because there are so many factors to be taken into an account, including the patient’s age, the geometry of the implant, the bone structure, and the biocompatibility of the material. All of these factors have an impact on how much stress and strain the implant will experience. One way to avoid future complications, including aseptic loosening or implant fracture, is to modify the shape of an existing prosthesis or use an ideal biomaterial [4]. Anthony L. Sabatini et al. This article reevaluated a number of hip stems. For all the stems, FE Analysis was carried out using different cross-sections. In addition to recording the displacement, von-Misses stress comparisons were performed for each of the stems at the predetermined places. The analysis was conducted using three materials: Ti-6Al-4V, SS316L, and Cr-Co-Mo. Ti-6Al- 4V showed less stress than the other two materials. The circular and eliptical cross-sections shaped even distribution of stresses throughout the length of the hip stem than the other cross-sections viz.; trapezoid and oval. This analysis could clarify the scenarios that should be avoided for hip implants that need stress shielding. For total hip replacements, additional anatomical designs are required [5]. M. Paglia et al. PEEK is a polyaromatic semi-crystalline thermoplastic polymer which was first developed for engineering applications by Victrex PLC in the early 1980s. It was initially made available for industrial use in the production of bearings, compressor plate valves, cable insulation, turbine blades, piston parts, and aircraft. PEEK is a polymer that is organic and colourless that is a member of the PAEK (polyaryl-ether-ketone) family. A single monomer makes it a homopolymer. This thermoplastic semi-crystalline polymer retains its outstanding chemical and mechanical characteristics even at elevated temperature. PEEK is stable at high temperatures due to its chemical compositions and structure, which facilitates simple manufacturing of PEEK implant components. When subjected to heat sterilising processes, PEEK is resistant to degradation. Due to its excellent thermal characteristics, superior wear resistance, great processability, inertness, corrosion resistance, high strength, and elastic modulus, PEEK is widely employed in both medical and engineering fields. In fact, it has an elastic modulus that is identical to human bone, indicating uniform stress distribution to the tissues around it. PEEK is a non-toxic, non-mutagenic substance that is extremely compatible with the tissues in its surrounding environment. As a result, it may be the perfect replacement for those who are allergic to titanium and other metals. PEEK has a more aesthetically pleasing appearance and doesn't have a metallic tone it seems beige with a hint of grey [6]. Jiaqi Zhang et al. Skull deformities are treated through cranioplasty, which involves raising the scalp and reshaping the skull with the original piece, titanium mesh, or solid biomaterial. Medical practitioners are increasingly using additive manufacturing technology, often known as 3D printing, to create specialized, replicas of tissues, organs, and bones, providing a viable solution with ideal anatomic fitting in the individual and skeletal reconstruction. Here, we analyze a patient from 15 years ago that had titanium mesh cranioplasty. The left eyebrow arch was weakened by the titanium mesh's unsightly appearance, which also caused a sinus tract to develop. An additively produced polyether ether ketone (PEEK) skull implant was used during cranioplasty. PEEK skull implants have been inserted successfully without any issues. To our information, this is the 1st reported case of direct use of fused filament fabrication (FFF) fabricated PEEK implant for cranial repair. The FFF-printed PEEK customized skull implant can possess simultaneously with adjustable
3.
International Research Journal
of Engineering and Technology (IRJET) e-ISSN: 2395-0056 Volume: 10 Issue: 08 | Aug 2023 www.irjet.net p-ISSN: 2395-0072 © 2023, IRJET | Impact Factor value: 8.226 | ISO 9001:2008 Certified Journal | Page 278 material thickness and more complex structure, tunable mechanical properties, and low processing cost compared to traditional manufacturing processes [7]. 3. PROBLEM IDENTIFICATION At present in medical field Titanium alloys, Stainless steel and Co-Cr alloy materials are been used for the artificial human hip stems. These materials have good mechanical and physical properties, they are very strong in nature. But the stiffness / elastic modulus of these materials are too much high when compared with the bone properties, due to this when the load applied on the hip joint the maximum load will be on the implant. When hip implant carries more load than the femur bone then there will be a wear between bone and the implant this effect is called as shield stressing, by this it gets loosen very quickly before its life span. Also, weight of the implant is more. Increases in bone porosity. Decrease in bone mass. There will be a magnetism effect and anode-cathode reactions. 4. OBJECTIVES To design for development of an artificial human hip stems based on fenestration using CAD modelling software i.e., SOLIDWORKS 2018. To perform FEA for all different types of fenestrated artificial human hip stems for Polyether–ether–ketone (PEEK) and Ti-6Al-4V materials under different conditions such as standing, walking, jumping and running using ANSYS Workbench 2022 R2. Results of the three different hip stems with PEEK and Ti-6Al-4V materials will be compared and one of the best will be suggested. To reduce the weight of human hip implant by using PEEK material instead of Titanium alloys, Stainless steel and Co-Cr alloy. To improve the strength, corrosion resistance and wear resistance of the hip stem by this stress shielding can be prevented. 5. METHODOLOGY Fig. 2 Methodology flow chart 6. DESIGN AND ANALYSIS OF HIP STEMS The CAD models have to be created in the computer environment. Here we designed a Hip Replacement of each different parts, the dimensions of each part is collected from previous record. SOLIDWORKS 2018 have been used in the modeling process. Fig. 3 Isometric view of hip implant
4.
International Research Journal
of Engineering and Technology (IRJET) e-ISSN: 2395-0056 Volume: 10 Issue: 08 | Aug 2023 www.irjet.net p-ISSN: 2395-0072 © 2023, IRJET | Impact Factor value: 8.226 | ISO 9001:2008 Certified Journal | Page 279 6.1 Different types of fenestration designs Fig. 4 Types of fenestration For hip replacement, artificial hip joints come in a variety of designs and shapes. Three different hip joint designs were used in this study, as shown in Fig. 4: a hip stem without fenestration, a hip stem with a big loop fenestration, and a hip stem with a slot fenestration [8]. The only difference in dimensions was fenestration. PEEK and Ti-6Al-4V were both employed as the materials. Materials were chosen for their high biocompatibility, durability, resistance to wear and corrosion, and strength. The material was thought to be uniform, isotropic, and linearly elastic. 7. RESULTS AND DISCUSSION The final model was assembled in SOLIDWORKS and imported to ANSYS Workbench software in .IGS format and the analysis is carried out in Static structural. So in this project we are going to consider three different types of hip stem designs namely, hip stem without fenestration, hip stem with big loop fenestration and hip stem with slot fenestration. Further these hip stems should be analyzed for different loading conditions like, standing, walking, jumping and running. Then comparing the results of PEEK material with commonly used Titanium based alloy Ti-6Al- 4V for all these hip stems. The mechanical property of these materials is given below Table 1. Table 1 Mechanical properties of the materials used for hip stems [9] We are going to use some different activities like standing, walking, etc. So the stress analysis on a hip prosthesis during various patient activities, such as standing, walking, jumping as well as in running. These loads are considered according to Aftab S et al. [10] on a patient who weighs 75 Kg, with an age group of around 35 years. Due to the symmetry of the human body, when a person is standing, their weight will be distributed evenly between their two legs. For this reason, the weight was divided in half and boundary conditions were applied to the finite element model. The analysis was performed under the assumption that the subject was standing normally, with a load of 370 N applied to the head of the femur at the hip joint and the hip stem fixed when in contact with the femoral bone. Similar to this, the hip stem was examined under a variety of situations derived from various human everyday activities, such as jumping, where a force of 750 N acting on one leg was applied, for walking an additional 800 N was applied, and running, where a load of 1463 N was applied. Also shown in the Table 2. Table 2 Loading conditions of hip joint for different daily activities [10] Activity Maximum Load (N) Standing 370 Walking 800 Jumping 750 Running 1463 The following Fig. 5 shows the meshing process which chosen to be 1mm element size. Fig. 5 Meshing process Table 3 Number of Elements used in analysis Element size: 1mm Types of hip stem Nodes Elements Without fenestration 77915 32325 With big loop fenestration 86111 36782 With slot fenestration 89874 39068 Sl.N o Material s Young’s Modulu s (GPa) Density (kg/m3 ) Poisson’ s ratio Yield strengt h (MPa) 1 PEEK 3.95 1320 0.3931 170 2 Ti-6Al-4V 120 4430 0.34 900
5.
International Research Journal
of Engineering and Technology (IRJET) e-ISSN: 2395-0056 Volume: 10 Issue: 08 | Aug 2023 www.irjet.net p-ISSN: 2395-0072 © 2023, IRJET | Impact Factor value: 8.226 | ISO 9001:2008 Certified Journal | Page 280 The below Fig. 6 indicates the fixed/support condition to the hip implant. Fig. 6 Support condition The Fig. 7 shows the applying of loading conditions which are mentioned in the Table 2. The force of 370 N magnitude is applied along the -y direction as shown in the following figure. Fig. 7 Applying the load 7.1 Computational Results 7.1.1 Masses of the different types of fenestrated hip stems These below mentioned masses are taken from the SOLIDWORKS software by applying the material properties of the PEEK and Ti-6Al-4V for the different hip stem designs. Fig. 8 Mass of the hip stem with big loop fenestration for PEEK material Fig. 9 Comparison of masses for different types of hip stem 7.1.2 Standing condition (370 N) The Fig. 10(a) refers to Von-misess stress produced in the hip stem without fenestration under standing condition when PEEK material is applied to the hip stem which is 34.106 MPa, which is similar for the remaining fenestrations. The Fig. 10(b) refers to Von-misess stress produced in the hip stem without fenestration under standing condition when Ti-6Al-4V material is applied to the hip stem which is 35.569 MPa, which is similar for the remaining fenestrations. 74.77 69.61 72.17 250.94 233.6 242.21 0 50 100 150 200 250 300 Hip stem without fenestration Hip stem with big loop fenestration Hip stem with slot fenestration MASS IN GRAMS TYPES OF HIP STEMS Masses of the hip stems in grams for PEEK Masses of the hip stems in grams for Ti-6Al-4V
6.
International Research Journal
of Engineering and Technology (IRJET) e-ISSN: 2395-0056 Volume: 10 Issue: 08 | Aug 2023 www.irjet.net p-ISSN: 2395-0072 © 2023, IRJET | Impact Factor value: 8.226 | ISO 9001:2008 Certified Journal | Page 281 (a) (b) Fig. 10 Hip stem without fenestration under standing condition for PEEK and Ti-6Al-4V material Fig. 11 Comparison of Von-Misses stress under Standing condition From Fig. 11 the von-misses stress of hip stem with slot fenestration for PEEK material is least when compared to others in standing condition. 7.1.3 Walking condition (800 N) The Fig. 12(a) refers to Von-misess stress produced in the with bigloop fenestration under walking condition when PEEK material is applied to the hip stem which is 78.393 MPa which is similar for the remaining fenestrations. The Fig. 12(b) refers to Von-misess stress produced in the hip stem with bigloop fenestration under walking condition when Ti-6Al-4V material is applied to the hip stem which is 84.475 MPa which is similar for the remaining fenestrations. (a) (b) Fig. 12 Hip stem with big loop fenestration under walking condition for PEEK and Ti-6Al-4V material Fig. 13 Comparison of Von-Misses stress under Walking condition From Fig. 13 the von-misses stress of hip stem with slot fenestration for PEEK material is least, when compared to others in walking condition. 7.1.4 Jumping condition (750 N) During jumping with the both legs 750 N load will be applied on one leg. The Fig 14(a) refers to Von-misess stress produced in the hip stem with slot fenestratation when PEEK material is applied to the hip stem which is 63.687 MPa, which is similar for the remaining fenestrations. The Fig. 14(b) refers to Von-misess stress produced in the hip stem with slot fenestratation when Ti-6Al-4V material is applied to the hip stem which is 65.48 MPa, which is similar for the remaining fenestrations. 34.106 36.257 31.419 35.569 39.07 32.303 0 5 10 15 20 25 30 35 40 45 Without fenestration With Big Loop fenestration With Slot fenestration Von-Misses Stress in MPa Types Of Hip stem PEEK Ti-6Al-4V 73.743 78.393 67.933 76.906 84.475 69.845 0 10 20 30 40 50 60 70 80 90 Without fenestration With Big Loop fenestration With Slot fenestration Von-Misses Stress in MPa Types Of Hip stem PEEK Ti-6Al-4V
7.
International Research Journal
of Engineering and Technology (IRJET) e-ISSN: 2395-0056 Volume: 10 Issue: 08 | Aug 2023 www.irjet.net p-ISSN: 2395-0072 © 2023, IRJET | Impact Factor value: 8.226 | ISO 9001:2008 Certified Journal | Page 282 (a) (b) Fig. 14 Hip stem with slot fenestration under jumping condition for PEEK and Ti-6Al-4V material Fig. 15 Comparison of Von-Misses stress under Jumping condition From Fig. 15 the von-misses stress of hip stem with slot fenestration for PEEK material is least, when compared to others jumping condition. 7.1.5 Running condition (1463 N) The Fig. 16(a) refers to Von-misess stress produced in the hip stem without fenestration under running condition when PEEK material is applied to the hip stem which is 134.86 MPa, which is similar for the remaining fenestrations. The Fig. 16(b) refers to Von-misess stress produced in the hip stem without fenestration under jumping condition when Ti-6Al-4V material is applied to the hip stem which is 140.64 MPa, which is similar for the remaining fenestrations. (a) (b) Fig. 16 Hip stem without fenestration under running condition for PEEK and Ti-6Al-4V material Fig. 17 Comparison of Von-Misses stress under Running condition From Fig. 17 the von-misses stress of hip stem with slot fenestration for PEEK material is least, when compared to others in running condition. 8. CONCLUSION In this work, three hip stem designs, namely without fenestration, with bigloop fenestration and with slot fenestration designs were modeled. For all designs, two materials PEEK and Ti-6Al-4V was used. PEEK is used because it as the similar stiffness as human femur bone and it as good wear properties, low moist absorption, low co-efficient of friction etc. All of these designs, which use materials with various physical properties, will be put through the rigours of daily activities like standing, walking, jumping, and running. Static structural analysis was carried out using ANSYS Workbench with the application of the loading boundary condition as per the work by Aftab S. et al. All three designs were found to suggest lower stress levels than the yield strength. Also, in these three designs for PEEK and Ti-6Al-4V materials under different loading conditions, the artificial human hip stem with slot fenestration for PEEK material has lesser Von-Misses stress under all different loading conditions as 69.134 73.494 63.687 72.1 79.196 65.48 0 10 20 30 40 50 60 70 80 90 Without fenestration With Big Loop fenestration With Slot fenestration Von-Misses Stress in MPa Types Of Hip stem PEEK Ti-6Al-4V 134.86 143.36 124.23 140.64 154.48 127.73 0 20 40 60 80 100 120 140 160 180 Without fenestration With Big Loop fenestration With Slot fenestration Von-Misses Stress in MPa Types Of Hip stem PEEK Ti-6Al-4V
8.
International Research Journal
of Engineering and Technology (IRJET) e-ISSN: 2395-0056 Volume: 10 Issue: 08 | Aug 2023 www.irjet.net p-ISSN: 2395-0072 © 2023, IRJET | Impact Factor value: 8.226 | ISO 9001:2008 Certified Journal | Page 283 mentioned above. Ti-6Al-4V has less deformation when compared to PEEK material for all the designs which were modeled in the current work. It is observed that for all the designs under different loading conditions the von-misses stress is almost similar for PEEK and Ti-6Al-4V material. Also, weight of the PEEK material is lesser than the Ti-6Al- 4V. So, PEEK material with slot fenestration can be suggested. REFERENCES [1] L. Guo et al., “On the design evolution of hip implants: A review,” Materials and Design, vol. 216. Elsevier Ltd, Apr. 01, 2022. doi: 10.1016/j.matdes.2022.110552. [2] S. Shuib, B. Sahari, A. Ahmed Shokri, and C. Soon Chai, “The Design Improvement of Hip Implant for Total Hip Replacement (THR),” Jurnal Kejuruteraan, vol. 20, no. 1, pp. 107–113, Dec. 2008, doi: 10.17576/jkukm-2008-20-10. [3] “Clinical Outcomes Following Total Hip Replacement,” EAS Journal of Medicine and Surgery, vol. 4, no. 6, pp. 134–139, Jun. 2022, doi: 10.36349/easjms.2022.v04i06.003. [4] M. Guzmán et al., “Finite Element Assessment of a Hybrid Proposal for Hip Stem, from a Standardized Base and Different Activities,” Applied Sciences (Switzerland), vol. 12, no. 16, Aug. 2022, doi: 10.3390/app12167963. [5] A. L. Sabatini and T. Goswami, “Hip implants VII: Finite element analysis and optimization of cross- sections,” Mater Des, vol. 29, no. 7, pp. 1438–1446, 2008, doi: 10.1016/j.matdes.2007.09.002. [6] M. Paglia, M. Beretta, V. Quinzi, and S. Colombo, “PEEK polymer in orthodontics: a scoping review,” Eur J Paediatr Dent, vol. 23, no. 2, pp. 137–139, 2022, doi: 10.23804/ejpd.2022.23.02.10. [7] J. Zhang et al., “Additively manufactured polyether ether ketone (PEEK) skull implant as an alternative to titanium mesh in cranioplasty,” Int J Bioprint, vol. 9, no. 1, Nov. 2022, doi: 10.18063/ijb.v9i1.634. [8] Ikhsan, A. R. Prabowo, J. M. Sohn, and J. Triyono, “Finite element analysis of different artificial hip stem designs based on fenestration under static loading,” in Procedia Structural Integrity, 2020, vol. 27, pp. 101–108. doi: 10.1016/j.prostr.2020.07.014. [9] Y. Jun and K. Choi, “Design of patient-specific hip implants based on the 3D geometry of the human femur,” Advances in Engineering Software, vol. 41, no. 4, pp. 537–547, 2010, doi: 10.1016/j.advengsoft.2009.10.016. [10] S. G. Aftab, A. Faisal, H. Hussain, B. Sreedhara, N. R. Babu, and B. A. Praveen, “Structural analysis of human femur bone to select an alternative composite material,” Mater Today Proc, vol. 54, pp. 141–146, Jan. 2022, doi: 10.1016/j.matpr.2021.08.197.
Télécharger maintenant