SlideShare a Scribd company logo
1 of 31
FLEXURAL BEHAVIOUR OF STEEL FIBRE 
REINFORCED AND LATEX MODIFIED 
FERROCEMENT SLABS 
BY 
ABRAHAM JAMES FINNEY 
DIVYA RUBAN 
SANTHOSH KUMAR 
GOVINDARAJ 
Project guide 
Mr.S.Sivachandran 
Asst professor 
Civil department
FERROCEMENT 
 Mixture of portland cement and sand applied over 
layers of woven or expanded steel mesh 
 Desired shape can be built. 
 Economical. 
 Lesser cross sectional area. 
 Relatively thin, compound curved sheets to make 
hulls for boats, shell roofs, water tanks, etc
LATEX 
• Latex -carboxylate styrene butadiene copolymer. 
• Improves bond strength. 
• Increases flexural & compression strength 
• Enhances impact strength. 
• Resistance to hydrolysis.
MICRO STEEL FIBER 
• Increases structural integrity. 
• It contains short discrete fibers that are uniformly 
distributed and randomly oriented. 
• Controls cracking. 
• They also reduce the permeability of slab. 
• It produce greater impact, abrasion, and shatter– 
resistance in concrete.
The Process of cutting the Welded mesh Micro Steel Fibre 
Ferrocement structure 
Construction of a Ferrocement tank
OBJECTIVES 
 To identify various ingredients used for Ferrocement slabs. 
 Preliminary study on properties of materials used in this project. 
 Mix design of cement : sand ratio is 1:2. 
 Comparison of mechanical properties of steel fibre reinforced 
cement mortar Ferrocement slabs and latex modified reinforced 
cement mortar Ferrocement slabs. 
 Comparison of Strength between two types of Ferrocement 
slabs by adding different layers of welded mesh. 
 Analysis of test results and arrive conclusions.
METHODOLOGY 
 Literature review on Ferrocement slabs. 
 Study of codal provisions. 
 Collection of welded mesh, steel fibres, latex and other ingredients. 
 Preliminary tests on materials. 
 Design of mortar mix. 
 Casting of the Ferrocement slabs. 
 Flexural strength and the mechanical properties such as ductility, 
toughness and energy of all specimens to be calculated. 
 Analysis of the test results. 
 Comparison of the results obtained. 
 Conclusion.
APPLICATIONS OF FERROCEMENT ELEMENTS 
 Strengthening of RC Beams using Ferrocement 
Laminates 
 Water Tanks 
 Secondary Roofing Slabs 
 Sunscreens 
 Hulls of boats 
 sculptures
MATERIALS SPECIFICATION 
 Cement: Portland Pozzolanic Cement of grade53 
 Fine aggregate: Ordinary river sand sieve of size 
2.36 . 
 Mortar: Cube specimens of size 70 mm x 70 mm x 
70 mm 
 Micro Steel fibres : length 13mm,dia 0.15mm 
 Steel Mesh: Diameter 1mm, grid size 1 X 1 cm.
DESIGN OF FERROCEMENT SLABS 
Batch A-Steel fibre reinforced cement mortar Ferrocement slab 
No. of 
speci 
mens 
Name of The 
Specimen 
No of layers of welded 
meshes 
Size of the slab 
(mm) 
Cement: Sand 
Mix ratio 
1 A1 4 600 × 300 1:2 
1 A2 6 600 × 300 1:2 
1 A3 8 600 × 300 1:2
Batch A- Steel fibre reinforced cement mortar Ferrocement slab 
 Weight of the cement = 20 kg 
 Weight of sand = 40 kg 
 Weight of water = 4.7 litre 
 Weight of steel fibres = 2 kg 
 Weight of the 4 layered mesh, A1 = 444gm 
 Weight of the 6layered mesh, A2 = 712gm 
 Weight of the 8 layered mesh, A3 = 1.045 kg 
 The total weight of the 4 layered slab = 9.55 kg 
 The total weight of the 6 layered slab = 11.36 kg 
 The total weight of the 8 layered slab = 11.85 kg
BATCH B: LATEX MODIFIED STEEL FIBRE 
REINFORCED FERROCEMENT SLAB 
No. of 
specimens 
Name of The 
Specimen 
No of layers of welded 
meshes 
Size of the slab 
(mm) 
Cement:Sand 
Mix ratio 
1 B1 4 600 × 300 1:2 
1 B2 6 600 × 300 1:2 
1 B3 8 600 × 300 1:2
Batch B 
 Weight of the cement = 20 kg 
 Weight of sand = 40 kg 
 Weight of water = 2.82litre 
 Weight of steel fibres = 2 kg 
 Weight of the latex = 950ml 
 Weight of the 4 layered mesh, B1 = 444gm 
 Weight of the 6layered mesh, B2 = 712 gm 
 Weight of the 8 layered mesh, B3 = 1.045 kg 
 The total weight of the 4 layered slab = 12.01 kg 
 The total weight of the 6 layered slab = 12.25 kg 
 The total weight of the 8 layered slab = 12.40 kg
TESTS ON MORTAR CUBE 
The mix proportion of the mortar cube 
Cement : sand : water ratio : 1 : 2 : 0.47 
Compressive Strength of mortar specimens 
S.no Days Compressive Strength (MPa) 
1 0 0 
2 3 21.50 
3 7 23.01 
4 28 33.22
COMPRESSIVE STRENGTH DEVELOPMENT CURVE FOR 
MORTAR CUBE
TESTING OF FERROCEMENT SLABS 
 Casting of the slabs specimen 
 Curing 
 Preparation for test specimens 
 Flexural test on Ferrocement slabs
Specimen placed in closed mould 
Casting of the slabs specimen
Deflectometer placed on the Ferrocement 
slab specimen 
The specimens are subjected to flexural 
strength test using UTM machine
DEFORMATION AND CRACKING BEHAVIOR OF 
SLABS UNDER FLEXURAL LOADING. 
Slab 
I.D 
First 
Cracking 
load 
(KN) 
1ST 
cracking 
central 
deflection 
(mm) 
No of 
cracks at 
first crack 
Spacing 
at first 
crack 
(mm) 
Ultimate 
load 
(KN) 
Ultimate 
load 
Deflection 
(mm) 
No of 
cracks at 
ultimate 
load 
Crack 
spacing at 
ultimate 
load 
(mm) 
A1 4 3.53 5 220 5.6 13.44 54 10 
A2 4 2.33 6 40 7.28 8.44 32 20 
A3 4.4 2.34 2 40 10.08 16.49 26 10 
B1 3.2 4.21 7 30 5.6 13.01 23 15 
B2 2 1.99 6 30 5.68 8.5 17 25 
B3 3 2.15 5 30 8.4 16.64 30 15
6 
5 
4 
3 
2 
1 
0 
0 5 10 15 
Load (KN) 
Deflection (mm) 
8 
7 
6 
5 
4 
3 
2 
1 
0 
0 2 4 6 8 10 
Load (KN) 
Deflection (mm) 
12 
10 
8 
6 
4 
2 
0 
0 2 4 6 8 10 12 14 16 18 
Load (KN) 
Deflection (mm) 
Batch A 
A1 A2 
A3
6 
5 
4 
3 
2 
1 
0 
0 5 10 15 
Load (KN) 
Deflection (mm) 
6 
5 
4 
3 
2 
1 
0 
0 5 10 15 20 
LOAD(Kn) 
DEFLECTION(mm) 
9 
8 
7 
6 
5 
4 
3 
2 
1 
0 
0 5 10 15 20 
LOAD (KN) 
DEFLECTION(mm) 
Batch B 
B1 
B3 
B2
FLEXURAL STRENGTH 
FORMULA USED 
R = P*L / b*푑2 
NO OF LAYERS FLEXURAL STRENGTH 
(Kn/m2) 
BATCH A BATCH B 
4 1.4388 1.5476 
6 1.7384 2.1384 
8 2.4355 4.1362
ENERGY ABSORPTION CAPACITY 
ENERGY = AREA UNDER THE LOAD DEFLECTION CURVE 
No of layers Batch A 
(KN mm) 
Batch B 
(KN mm) 
4 2.62 2.823 
6 4.977 5.83 
8 5.22 6.15
COMPARISON OF ENERGY ABSORPTION 
CAPACITY 
8 
7 
6 
5 
4 
3 
2 
1 
0 
1 2 3 4 
No of layers 
Ferro- steel fibre (J/sec) 
Ferro-latex and steel fibre (J/Sec)
CALCULATION OF DUCTILITY VALUE 
Formula used 
Ductility = Ultimate load / First cracking load 
No of layers Batch A Batch B 
4 1.4 1.875 
6 1.82 2.84 
8 2.7 3.36
COMPARISON OF DUCTILITY VALUE 
1400 
1200 
1000 
800 
600 
400 
200 
0 
1 2 3 4 
No of layers 
Ferro- steel fibre 
Ferro-latex and steel fibre
CALCULATION OF TOUGHNESS VALUE: 
Toughness = Total area of the curve/ area up to first crack obtained curve. 
No of layers Batch A Batch B 
4 382.86 589.83 
6 628.31 1026.02 
8 1180.33 1337.55
COMPARISON OF TOUGHNESS VALUE: 
1400 
1200 
1000 
800 
600 
400 
200 
0 
1 2 3 4 
No of layers 
Ferro- steel fibre (mm) 
Ferro-latex and steel fibre (mm)
RESULTS 
The below table shows the increase in percentage of the Flexural strength 
and mechanical properties of Latex modified Steel fibre reinforced 
ferrocement slabs over Steel fibre reinforced ferrocement slabs 
Specimen Flexural 
strength 
Energy 
absorption 
value 
Ductility Toughness 
B1>A1 7.69 % 7.75 % 33.9% 54.05% 
B2>A2 23.82 % 17.14% 56.04% 63.21% 
B3>A3 69.95 % 17.82% 24% 13.32%
CONCLUSION 
Thus from the above comparison it is evident that the 
latex modified steel fibre reinforced cement mortar 
Ferro cement slabs of 4, 6 and 8 layers are having a 
greater flexural strength and mechanical properties.
Thank You

More Related Content

What's hot

What's hot (20)

Ferrocement
FerrocementFerrocement
Ferrocement
 
Fibre Reinforced concrete
Fibre Reinforced concreteFibre Reinforced concrete
Fibre Reinforced concrete
 
Ferrocement
Ferrocement Ferrocement
Ferrocement
 
6. fibre reinforced concrete
6. fibre reinforced concrete6. fibre reinforced concrete
6. fibre reinforced concrete
 
Civil Engineering Internship Presentation-Anis Rahman Khokan
Civil Engineering Internship Presentation-Anis Rahman KhokanCivil Engineering Internship Presentation-Anis Rahman Khokan
Civil Engineering Internship Presentation-Anis Rahman Khokan
 
Strengthening Of Beams for flexure Using FRP
Strengthening Of Beams  for flexure Using FRPStrengthening Of Beams  for flexure Using FRP
Strengthening Of Beams for flexure Using FRP
 
Strength and durability of concrete - Repair and rehabilitation of structures...
Strength and durability of concrete - Repair and rehabilitation of structures...Strength and durability of concrete - Repair and rehabilitation of structures...
Strength and durability of concrete - Repair and rehabilitation of structures...
 
Fiber reinforced concrete application and properties
Fiber reinforced concrete application and propertiesFiber reinforced concrete application and properties
Fiber reinforced concrete application and properties
 
a project on fibre-reinforced-concrete.
a project on fibre-reinforced-concrete.a project on fibre-reinforced-concrete.
a project on fibre-reinforced-concrete.
 
Ferrocement ppt
Ferrocement pptFerrocement ppt
Ferrocement ppt
 
Cracks in concrete
Cracks in concreteCracks in concrete
Cracks in concrete
 
Ferro cement
Ferro cementFerro cement
Ferro cement
 
Polymer concrete and fiber reinforced polymer concrete
Polymer concrete and fiber reinforced polymer concretePolymer concrete and fiber reinforced polymer concrete
Polymer concrete and fiber reinforced polymer concrete
 
CONCRETE MIX DESIGN AS PER IS 10262:2009
 CONCRETE MIX DESIGN AS PER IS 10262:2009  CONCRETE MIX DESIGN AS PER IS 10262:2009
CONCRETE MIX DESIGN AS PER IS 10262:2009
 
Shri
ShriShri
Shri
 
Fibre reinforced concrete
Fibre reinforced concreteFibre reinforced concrete
Fibre reinforced concrete
 
Industrial building
Industrial buildingIndustrial building
Industrial building
 
Kiran more (retrofitting presentation)te b
Kiran more (retrofitting presentation)te bKiran more (retrofitting presentation)te b
Kiran more (retrofitting presentation)te b
 
r.c.c.
r.c.c.r.c.c.
r.c.c.
 
Fibre reinforced concrete
Fibre reinforced concreteFibre reinforced concrete
Fibre reinforced concrete
 

Similar to Flexural behaviour of fibre reinforced ferrocement concrete

Experimental behaviour and analysis of stress in rigid pavement
Experimental behaviour and analysis of stress in rigid pavementExperimental behaviour and analysis of stress in rigid pavement
Experimental behaviour and analysis of stress in rigid pavement
Vivek Loyola
 

Similar to Flexural behaviour of fibre reinforced ferrocement concrete (20)

Knowledge and Experience of Menopause - A Rural Based Study in Aligarh
Knowledge and Experience of Menopause - A Rural Based Study in AligarhKnowledge and Experience of Menopause - A Rural Based Study in Aligarh
Knowledge and Experience of Menopause - A Rural Based Study in Aligarh
 
Punching Shear Strength of High Strength Fibre Reinforced Concrete Slabs
Punching Shear Strength of High Strength Fibre Reinforced  Concrete SlabsPunching Shear Strength of High Strength Fibre Reinforced  Concrete Slabs
Punching Shear Strength of High Strength Fibre Reinforced Concrete Slabs
 
Experimental Study Compared With American Code - ConcreteFilled – Double Skin...
Experimental Study Compared With American Code - ConcreteFilled – Double Skin...Experimental Study Compared With American Code - ConcreteFilled – Double Skin...
Experimental Study Compared With American Code - ConcreteFilled – Double Skin...
 
Experimental Investigation on Effect of Curtailed reinforcement in R.C beams
Experimental Investigation on Effect of Curtailed reinforcement in R.C beamsExperimental Investigation on Effect of Curtailed reinforcement in R.C beams
Experimental Investigation on Effect of Curtailed reinforcement in R.C beams
 
IRJET- Experimental Investigation on Concrete using Perlite as Partialy Repla...
IRJET- Experimental Investigation on Concrete using Perlite as Partialy Repla...IRJET- Experimental Investigation on Concrete using Perlite as Partialy Repla...
IRJET- Experimental Investigation on Concrete using Perlite as Partialy Repla...
 
main ppt.pptx
main ppt.pptxmain ppt.pptx
main ppt.pptx
 
IRJET- Flexural Strength of Reinforced Concrete Beam with Hollow Core at Vari...
IRJET- Flexural Strength of Reinforced Concrete Beam with Hollow Core at Vari...IRJET- Flexural Strength of Reinforced Concrete Beam with Hollow Core at Vari...
IRJET- Flexural Strength of Reinforced Concrete Beam with Hollow Core at Vari...
 
IRJET- Experimental Study on Partial Replacement of Coarse Aggregate by C...
IRJET-  	  Experimental Study on Partial Replacement of Coarse Aggregate by C...IRJET-  	  Experimental Study on Partial Replacement of Coarse Aggregate by C...
IRJET- Experimental Study on Partial Replacement of Coarse Aggregate by C...
 
Wear and Tribology Experimental Lab report
Wear and Tribology Experimental Lab reportWear and Tribology Experimental Lab report
Wear and Tribology Experimental Lab report
 
Experimental behaviour and analysis of stress in rigid pavement
Experimental behaviour and analysis of stress in rigid pavementExperimental behaviour and analysis of stress in rigid pavement
Experimental behaviour and analysis of stress in rigid pavement
 
Comparative Study on Flexural Strength of M20 Grade Beam with Lapping of Bars
Comparative Study on Flexural Strength of M20 Grade Beam with Lapping of BarsComparative Study on Flexural Strength of M20 Grade Beam with Lapping of Bars
Comparative Study on Flexural Strength of M20 Grade Beam with Lapping of Bars
 
G012543846
G012543846G012543846
G012543846
 
Experimental Investigation on Replacement of Magnetic Water and Partial Repla...
Experimental Investigation on Replacement of Magnetic Water and Partial Repla...Experimental Investigation on Replacement of Magnetic Water and Partial Repla...
Experimental Investigation on Replacement of Magnetic Water and Partial Repla...
 
IRJET- An Experimental Study of Ductile Behavior of Ferrocement Slab
IRJET- An Experimental Study of Ductile Behavior of Ferrocement SlabIRJET- An Experimental Study of Ductile Behavior of Ferrocement Slab
IRJET- An Experimental Study of Ductile Behavior of Ferrocement Slab
 
IRJET- An Experimental Investigation of steel Concrete Composite Deck Slab
IRJET- An Experimental Investigation of steel Concrete Composite Deck SlabIRJET- An Experimental Investigation of steel Concrete Composite Deck Slab
IRJET- An Experimental Investigation of steel Concrete Composite Deck Slab
 
IRJET- Experimental Investigation on Partial Replacement of M-Sand by Steel Slag
IRJET- Experimental Investigation on Partial Replacement of M-Sand by Steel SlagIRJET- Experimental Investigation on Partial Replacement of M-Sand by Steel Slag
IRJET- Experimental Investigation on Partial Replacement of M-Sand by Steel Slag
 
Ijciet 10 01_002
Ijciet 10 01_002Ijciet 10 01_002
Ijciet 10 01_002
 
CFST Column Report
CFST Column ReportCFST Column Report
CFST Column Report
 
IRJET- VStudy on Strength and Durability Properties of Concrete using Steel S...
IRJET- VStudy on Strength and Durability Properties of Concrete using Steel S...IRJET- VStudy on Strength and Durability Properties of Concrete using Steel S...
IRJET- VStudy on Strength and Durability Properties of Concrete using Steel S...
 
Strength and geotechnical characterization of copper slag as partial replacem...
Strength and geotechnical characterization of copper slag as partial replacem...Strength and geotechnical characterization of copper slag as partial replacem...
Strength and geotechnical characterization of copper slag as partial replacem...
 

Recently uploaded

Kuwait City MTP kit ((+919101817206)) Buy Abortion Pills Kuwait
Kuwait City MTP kit ((+919101817206)) Buy Abortion Pills KuwaitKuwait City MTP kit ((+919101817206)) Buy Abortion Pills Kuwait
Kuwait City MTP kit ((+919101817206)) Buy Abortion Pills Kuwait
jaanualu31
 
Call Girls in South Ex (delhi) call me [🔝9953056974🔝] escort service 24X7
Call Girls in South Ex (delhi) call me [🔝9953056974🔝] escort service 24X7Call Girls in South Ex (delhi) call me [🔝9953056974🔝] escort service 24X7
Call Girls in South Ex (delhi) call me [🔝9953056974🔝] escort service 24X7
9953056974 Low Rate Call Girls In Saket, Delhi NCR
 
Verification of thevenin's theorem for BEEE Lab (1).pptx
Verification of thevenin's theorem for BEEE Lab (1).pptxVerification of thevenin's theorem for BEEE Lab (1).pptx
Verification of thevenin's theorem for BEEE Lab (1).pptx
chumtiyababu
 
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
ssuser89054b
 
Standard vs Custom Battery Packs - Decoding the Power Play
Standard vs Custom Battery Packs - Decoding the Power PlayStandard vs Custom Battery Packs - Decoding the Power Play
Standard vs Custom Battery Packs - Decoding the Power Play
Epec Engineered Technologies
 

Recently uploaded (20)

HAND TOOLS USED AT ELECTRONICS WORK PRESENTED BY KOUSTAV SARKAR
HAND TOOLS USED AT ELECTRONICS WORK PRESENTED BY KOUSTAV SARKARHAND TOOLS USED AT ELECTRONICS WORK PRESENTED BY KOUSTAV SARKAR
HAND TOOLS USED AT ELECTRONICS WORK PRESENTED BY KOUSTAV SARKAR
 
Tamil Call Girls Bhayandar WhatsApp +91-9930687706, Best Service
Tamil Call Girls Bhayandar WhatsApp +91-9930687706, Best ServiceTamil Call Girls Bhayandar WhatsApp +91-9930687706, Best Service
Tamil Call Girls Bhayandar WhatsApp +91-9930687706, Best Service
 
DC MACHINE-Motoring and generation, Armature circuit equation
DC MACHINE-Motoring and generation, Armature circuit equationDC MACHINE-Motoring and generation, Armature circuit equation
DC MACHINE-Motoring and generation, Armature circuit equation
 
Online food ordering system project report.pdf
Online food ordering system project report.pdfOnline food ordering system project report.pdf
Online food ordering system project report.pdf
 
Kuwait City MTP kit ((+919101817206)) Buy Abortion Pills Kuwait
Kuwait City MTP kit ((+919101817206)) Buy Abortion Pills KuwaitKuwait City MTP kit ((+919101817206)) Buy Abortion Pills Kuwait
Kuwait City MTP kit ((+919101817206)) Buy Abortion Pills Kuwait
 
Wadi Rum luxhotel lodge Analysis case study.pptx
Wadi Rum luxhotel lodge Analysis case study.pptxWadi Rum luxhotel lodge Analysis case study.pptx
Wadi Rum luxhotel lodge Analysis case study.pptx
 
PE 459 LECTURE 2- natural gas basic concepts and properties
PE 459 LECTURE 2- natural gas basic concepts and propertiesPE 459 LECTURE 2- natural gas basic concepts and properties
PE 459 LECTURE 2- natural gas basic concepts and properties
 
Online electricity billing project report..pdf
Online electricity billing project report..pdfOnline electricity billing project report..pdf
Online electricity billing project report..pdf
 
Call Girls in South Ex (delhi) call me [🔝9953056974🔝] escort service 24X7
Call Girls in South Ex (delhi) call me [🔝9953056974🔝] escort service 24X7Call Girls in South Ex (delhi) call me [🔝9953056974🔝] escort service 24X7
Call Girls in South Ex (delhi) call me [🔝9953056974🔝] escort service 24X7
 
Bhubaneswar🌹Call Girls Bhubaneswar ❤Komal 9777949614 💟 Full Trusted CALL GIRL...
Bhubaneswar🌹Call Girls Bhubaneswar ❤Komal 9777949614 💟 Full Trusted CALL GIRL...Bhubaneswar🌹Call Girls Bhubaneswar ❤Komal 9777949614 💟 Full Trusted CALL GIRL...
Bhubaneswar🌹Call Girls Bhubaneswar ❤Komal 9777949614 💟 Full Trusted CALL GIRL...
 
Generative AI or GenAI technology based PPT
Generative AI or GenAI technology based PPTGenerative AI or GenAI technology based PPT
Generative AI or GenAI technology based PPT
 
Verification of thevenin's theorem for BEEE Lab (1).pptx
Verification of thevenin's theorem for BEEE Lab (1).pptxVerification of thevenin's theorem for BEEE Lab (1).pptx
Verification of thevenin's theorem for BEEE Lab (1).pptx
 
School management system project Report.pdf
School management system project Report.pdfSchool management system project Report.pdf
School management system project Report.pdf
 
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
 
Thermal Engineering Unit - I & II . ppt
Thermal Engineering  Unit - I & II . pptThermal Engineering  Unit - I & II . ppt
Thermal Engineering Unit - I & II . ppt
 
Unleashing the Power of the SORA AI lastest leap
Unleashing the Power of the SORA AI lastest leapUnleashing the Power of the SORA AI lastest leap
Unleashing the Power of the SORA AI lastest leap
 
S1S2 B.Arch MGU - HOA1&2 Module 3 -Temple Architecture of Kerala.pptx
S1S2 B.Arch MGU - HOA1&2 Module 3 -Temple Architecture of Kerala.pptxS1S2 B.Arch MGU - HOA1&2 Module 3 -Temple Architecture of Kerala.pptx
S1S2 B.Arch MGU - HOA1&2 Module 3 -Temple Architecture of Kerala.pptx
 
Standard vs Custom Battery Packs - Decoding the Power Play
Standard vs Custom Battery Packs - Decoding the Power PlayStandard vs Custom Battery Packs - Decoding the Power Play
Standard vs Custom Battery Packs - Decoding the Power Play
 
Design For Accessibility: Getting it right from the start
Design For Accessibility: Getting it right from the startDesign For Accessibility: Getting it right from the start
Design For Accessibility: Getting it right from the start
 
Thermal Engineering-R & A / C - unit - V
Thermal Engineering-R & A / C - unit - VThermal Engineering-R & A / C - unit - V
Thermal Engineering-R & A / C - unit - V
 

Flexural behaviour of fibre reinforced ferrocement concrete

  • 1. FLEXURAL BEHAVIOUR OF STEEL FIBRE REINFORCED AND LATEX MODIFIED FERROCEMENT SLABS BY ABRAHAM JAMES FINNEY DIVYA RUBAN SANTHOSH KUMAR GOVINDARAJ Project guide Mr.S.Sivachandran Asst professor Civil department
  • 2. FERROCEMENT  Mixture of portland cement and sand applied over layers of woven or expanded steel mesh  Desired shape can be built.  Economical.  Lesser cross sectional area.  Relatively thin, compound curved sheets to make hulls for boats, shell roofs, water tanks, etc
  • 3. LATEX • Latex -carboxylate styrene butadiene copolymer. • Improves bond strength. • Increases flexural & compression strength • Enhances impact strength. • Resistance to hydrolysis.
  • 4. MICRO STEEL FIBER • Increases structural integrity. • It contains short discrete fibers that are uniformly distributed and randomly oriented. • Controls cracking. • They also reduce the permeability of slab. • It produce greater impact, abrasion, and shatter– resistance in concrete.
  • 5. The Process of cutting the Welded mesh Micro Steel Fibre Ferrocement structure Construction of a Ferrocement tank
  • 6. OBJECTIVES  To identify various ingredients used for Ferrocement slabs.  Preliminary study on properties of materials used in this project.  Mix design of cement : sand ratio is 1:2.  Comparison of mechanical properties of steel fibre reinforced cement mortar Ferrocement slabs and latex modified reinforced cement mortar Ferrocement slabs.  Comparison of Strength between two types of Ferrocement slabs by adding different layers of welded mesh.  Analysis of test results and arrive conclusions.
  • 7. METHODOLOGY  Literature review on Ferrocement slabs.  Study of codal provisions.  Collection of welded mesh, steel fibres, latex and other ingredients.  Preliminary tests on materials.  Design of mortar mix.  Casting of the Ferrocement slabs.  Flexural strength and the mechanical properties such as ductility, toughness and energy of all specimens to be calculated.  Analysis of the test results.  Comparison of the results obtained.  Conclusion.
  • 8. APPLICATIONS OF FERROCEMENT ELEMENTS  Strengthening of RC Beams using Ferrocement Laminates  Water Tanks  Secondary Roofing Slabs  Sunscreens  Hulls of boats  sculptures
  • 9. MATERIALS SPECIFICATION  Cement: Portland Pozzolanic Cement of grade53  Fine aggregate: Ordinary river sand sieve of size 2.36 .  Mortar: Cube specimens of size 70 mm x 70 mm x 70 mm  Micro Steel fibres : length 13mm,dia 0.15mm  Steel Mesh: Diameter 1mm, grid size 1 X 1 cm.
  • 10. DESIGN OF FERROCEMENT SLABS Batch A-Steel fibre reinforced cement mortar Ferrocement slab No. of speci mens Name of The Specimen No of layers of welded meshes Size of the slab (mm) Cement: Sand Mix ratio 1 A1 4 600 × 300 1:2 1 A2 6 600 × 300 1:2 1 A3 8 600 × 300 1:2
  • 11. Batch A- Steel fibre reinforced cement mortar Ferrocement slab  Weight of the cement = 20 kg  Weight of sand = 40 kg  Weight of water = 4.7 litre  Weight of steel fibres = 2 kg  Weight of the 4 layered mesh, A1 = 444gm  Weight of the 6layered mesh, A2 = 712gm  Weight of the 8 layered mesh, A3 = 1.045 kg  The total weight of the 4 layered slab = 9.55 kg  The total weight of the 6 layered slab = 11.36 kg  The total weight of the 8 layered slab = 11.85 kg
  • 12. BATCH B: LATEX MODIFIED STEEL FIBRE REINFORCED FERROCEMENT SLAB No. of specimens Name of The Specimen No of layers of welded meshes Size of the slab (mm) Cement:Sand Mix ratio 1 B1 4 600 × 300 1:2 1 B2 6 600 × 300 1:2 1 B3 8 600 × 300 1:2
  • 13. Batch B  Weight of the cement = 20 kg  Weight of sand = 40 kg  Weight of water = 2.82litre  Weight of steel fibres = 2 kg  Weight of the latex = 950ml  Weight of the 4 layered mesh, B1 = 444gm  Weight of the 6layered mesh, B2 = 712 gm  Weight of the 8 layered mesh, B3 = 1.045 kg  The total weight of the 4 layered slab = 12.01 kg  The total weight of the 6 layered slab = 12.25 kg  The total weight of the 8 layered slab = 12.40 kg
  • 14. TESTS ON MORTAR CUBE The mix proportion of the mortar cube Cement : sand : water ratio : 1 : 2 : 0.47 Compressive Strength of mortar specimens S.no Days Compressive Strength (MPa) 1 0 0 2 3 21.50 3 7 23.01 4 28 33.22
  • 15. COMPRESSIVE STRENGTH DEVELOPMENT CURVE FOR MORTAR CUBE
  • 16. TESTING OF FERROCEMENT SLABS  Casting of the slabs specimen  Curing  Preparation for test specimens  Flexural test on Ferrocement slabs
  • 17. Specimen placed in closed mould Casting of the slabs specimen
  • 18. Deflectometer placed on the Ferrocement slab specimen The specimens are subjected to flexural strength test using UTM machine
  • 19. DEFORMATION AND CRACKING BEHAVIOR OF SLABS UNDER FLEXURAL LOADING. Slab I.D First Cracking load (KN) 1ST cracking central deflection (mm) No of cracks at first crack Spacing at first crack (mm) Ultimate load (KN) Ultimate load Deflection (mm) No of cracks at ultimate load Crack spacing at ultimate load (mm) A1 4 3.53 5 220 5.6 13.44 54 10 A2 4 2.33 6 40 7.28 8.44 32 20 A3 4.4 2.34 2 40 10.08 16.49 26 10 B1 3.2 4.21 7 30 5.6 13.01 23 15 B2 2 1.99 6 30 5.68 8.5 17 25 B3 3 2.15 5 30 8.4 16.64 30 15
  • 20. 6 5 4 3 2 1 0 0 5 10 15 Load (KN) Deflection (mm) 8 7 6 5 4 3 2 1 0 0 2 4 6 8 10 Load (KN) Deflection (mm) 12 10 8 6 4 2 0 0 2 4 6 8 10 12 14 16 18 Load (KN) Deflection (mm) Batch A A1 A2 A3
  • 21. 6 5 4 3 2 1 0 0 5 10 15 Load (KN) Deflection (mm) 6 5 4 3 2 1 0 0 5 10 15 20 LOAD(Kn) DEFLECTION(mm) 9 8 7 6 5 4 3 2 1 0 0 5 10 15 20 LOAD (KN) DEFLECTION(mm) Batch B B1 B3 B2
  • 22. FLEXURAL STRENGTH FORMULA USED R = P*L / b*푑2 NO OF LAYERS FLEXURAL STRENGTH (Kn/m2) BATCH A BATCH B 4 1.4388 1.5476 6 1.7384 2.1384 8 2.4355 4.1362
  • 23. ENERGY ABSORPTION CAPACITY ENERGY = AREA UNDER THE LOAD DEFLECTION CURVE No of layers Batch A (KN mm) Batch B (KN mm) 4 2.62 2.823 6 4.977 5.83 8 5.22 6.15
  • 24. COMPARISON OF ENERGY ABSORPTION CAPACITY 8 7 6 5 4 3 2 1 0 1 2 3 4 No of layers Ferro- steel fibre (J/sec) Ferro-latex and steel fibre (J/Sec)
  • 25. CALCULATION OF DUCTILITY VALUE Formula used Ductility = Ultimate load / First cracking load No of layers Batch A Batch B 4 1.4 1.875 6 1.82 2.84 8 2.7 3.36
  • 26. COMPARISON OF DUCTILITY VALUE 1400 1200 1000 800 600 400 200 0 1 2 3 4 No of layers Ferro- steel fibre Ferro-latex and steel fibre
  • 27. CALCULATION OF TOUGHNESS VALUE: Toughness = Total area of the curve/ area up to first crack obtained curve. No of layers Batch A Batch B 4 382.86 589.83 6 628.31 1026.02 8 1180.33 1337.55
  • 28. COMPARISON OF TOUGHNESS VALUE: 1400 1200 1000 800 600 400 200 0 1 2 3 4 No of layers Ferro- steel fibre (mm) Ferro-latex and steel fibre (mm)
  • 29. RESULTS The below table shows the increase in percentage of the Flexural strength and mechanical properties of Latex modified Steel fibre reinforced ferrocement slabs over Steel fibre reinforced ferrocement slabs Specimen Flexural strength Energy absorption value Ductility Toughness B1>A1 7.69 % 7.75 % 33.9% 54.05% B2>A2 23.82 % 17.14% 56.04% 63.21% B3>A3 69.95 % 17.82% 24% 13.32%
  • 30. CONCLUSION Thus from the above comparison it is evident that the latex modified steel fibre reinforced cement mortar Ferro cement slabs of 4, 6 and 8 layers are having a greater flexural strength and mechanical properties.