Pushover is a static-nonlinear analysis method where a structure is subjected to gravity loading and a monotonic displacement-controlled lateral load pattern which continuously increases through elastic and inelastic behavior until an ultimate condition is reached. Lateral load may represent the range of base shear induced by earthquake loading, and its configuration may be proportional to the distribution of mass along building height, mode shapes, or another practical means.
The static pushover analysis is becoming a popular tool for seismic performance evaluation of existing and new structures. The expectation is that the pushover analysis will provide adequate information on seismic demands imposed by the design ground motion on the structural system and its components. The purpose of the paper is to summarize the basic concepts on which the pushover analysis can be based, assess the accuracy of pushover predictions, identify conditions under which the pushover will provide adequate information and, perhaps more importantly, identify cases in which the pushover predictions will be inadequate or even misleading.
2. Pushover is a static-nonlinear analysis method where a structure is
subjected to gravity loading and a monotonic displacement-
controlled lateral load pattern
Lateral load may represent the range of base shear induced by
earthquake loading
Output generates a static-pushover curve which plots a strength-
based parameter against deflection.
For example, performance may relate the strength level achieved in
certain members against displacement at the top of the structure
Results provide information about ductile capacity of the
structural system and indicate the mechanism, load level and
deflection at which failure occurs
3. Purpose
How will a structure perform when subjected to given level
of earthquake
Types of performance check:
◦ Linear static analysis
◦ Linear dynamic analysis
◦ Non Linear static analysis (Push over analysis)
◦ Non Linear dynamic analysis
4. The existing building can become seismically deficient since seismic design
code requirements are constantly upgraded and advancement in engineering
knowledge.
Further, Indian buildings built over past two decades are seismically deficient
because of lack of awareness regarding seismic behavior of structures.
The widespread damage especially to RC buildings during earthquakes
exposed the construction practices being adopted around the world and
generated a great demand for seismic evaluation and retrofitting of existing
building stocks.
5. Better understand building behavior
- Identify weak elements
- Realistic prediction of element demands
Less conservative acceptance criteria can be used
Simple to perform
6. Goal is to predict peak response of building and
components for a given earthquake
7. Construct Pushover curve
Select earthquake level(s) to check
Select performance level(s) to check
Select acceptance criteria for each performance level
Verify acceptance
◦ Capacity Spectrum Method (ATC-40)
◦ Displacement Coefficient Method (FEMA 273)
8. Define Structural Model
◦ Elements (components)
◦ Strength - deformation properties
Define Loads
◦ Gravity
◦ Lateral load pattern
Select Control Displacements or Drifts
Perform Pushover Analysis
9. Modeling the structure
Perform a series of linear analysis
Develop push over curve
Determine effective dynamic properties
Determine demand lateral displacement
Check adequacy of elements
10. Understand the structure before attempting a non
linear analysis
Identify the following things,
◦ Critical elements
◦ Probable yield failure modes
◦ Importance of torsional behavior and need for 3D
modeling
11. For best estimates design or specified strengths
should be used in determining material capacities
use of artificially low nominal strengths will result
in under estimates of strength demands on some
elements
Expected Steel yield - 1.25Fy
Expected concrete compressive strength 1.33f’c
12. Select a loading pattern for the structure
◦ Loading pattern should produce a deflected shape in the
structure similar to that it would undergo in earthquake
response
Loading Pattern Alternatives
◦ Inverse triangular
◦ Rectangular
◦ First mode
◦ Modal dynamic
◦ Modal dynamic variant
◦ Multi-mode
FEMA 356 requires use of at least:
◦ Inverse triangular or first mode
◦ Rectangular
FEMA 440 found that there is not substantial difference in the
accuracy produced by the various load patterns
13. Develop Pushover Curve
Determine Effective Dynamic Properties
◦ Initially, perform elastic modal analysis to determine
fundamental period of structure, T
◦ Determine initial stiffness, ki from pushover curve as V1/Δ1
◦ Determine effective stiffness, ke at 60% of yield force from
pushover curve
14. Determine Demand Lateral Displacement
◦ Capacity Spectrum Method - detailed in ATC-40
◦ Displacement Coefficient Method - detailed in FEMA-273
ATC 40 and FEMA 273 (FEDERAL EMERGENCY MANAGEMENT AGENCY are
the documents containing
◦ Modeling procedures
◦ Acceptance criterias
◦ Analysis procedure for pushover analysis
16. Estimate Target Displacement
oEstimate effective elastic stiffness, Ke
oEstimate post yield stiffness, Ks
oEstimate effective fundamental period, Te
oCalculate target roof displacement as
C0 Relates spectral to roof displacement
C1 Modifier for inelastic displacement
C2 Modifier for hysteresis loop shape
C3 Modifier for second order effects
)4/( 22
3210 ea TSCCCC
17. Magnitude of the structural loading is incrementally
increased, which leads to the identification of
◦ weak links
◦ Failure modes of the structure
ATC 40 and FEMA 273 are the documents containing
◦ Modeling procedures
◦ Acceptance criterias
◦ Analysis procedure for pushover analysis
18. These documents define force deformation criteria for hinges used in
pushover analysis.
Five points labeled A, B, C, D, and E are used to define the force
deflection behavior of the hinge
Three points labeled IO, LS and CP are used to define the acceptance
criteria for the hinge. (IO, LS and CP stand for Immediate Occupancy,
Life Safety and Collapse Prevention respectively.)
The values assigned to each of these points vary depending on the
type of member as well as many other parameters defined in the ATC-
40 and FEMA-273 documents.
19. Create the basic computer model (without the pushover
data)
Define properties and acceptance criteria for the pushover
hinges
The program includes several built-in default hinge
properties that are based on average values from ATC-40
for concrete members and average values from FEMA-273
for steel members.
These built in properties can be useful for preliminary
analyses, but user-defined properties are recommended
for final analyses. This example uses default properties
20. Locate the pushover hinges on the model by selecting one
or more frame members
Define the pushover load cases
o Gravity load case and lateral load case .
o Pushover load cases can be force controlled,
ie. pushed to a certain defined force level,
or they can be displacement controlled,
ie. pushed to a specified displacement.
Run the basic static analysis and, if desired, dynamic
analysis. Then run the static nonlinear pushover analysis
21. Display the pushover curve, the number of hinges in each
state as defined in Figure 1 can be viewed
Display the capacity spectrum curve. The performance
point for a given set of values is defined by the intersection
of the capacity curve (green) and the single demand
spectrum curve (yellow).
Review the pushover displaced shape and sequence of
hinge formation on a step-by-step basis