Ce diaporama a bien été signalé.
Nous utilisons votre profil LinkedIn et vos données d’activité pour vous proposer des publicités personnalisées et pertinentes. Vous pouvez changer vos préférences de publicités à tout moment.

Led corn bulb test report - www.ngtlight.com

1 241 vues

Publié le

LED Corn Bulb Test report - www.ngtlight.com
For more information,please Visit Our website:www.ngtlight.com
Email : sales@nuoguan.net

Publié dans : Sports
  • Login to see the comments

  • Soyez le premier à aimer ceci

Led corn bulb test report - www.ngtlight.com

  1. 1. Test Report Report No. SCL0lG006l77 Page 1 of9 Applicant SHENZHEN NUOGUAN TECHNOLOGY CO. ,LTD Address 902ROOM,9/F, LONGSHENG TIMES BUILDINGJNDUSTIAL WEST ROAD. LONGSHENG COMMUNITYDALANG STREET, LONGHUA NEW DISTRICT, SHENZHEN, GUANGDONG, P.R. CHlNA. The following sample(s) and sample information was/ were submitted and identified by/ on the behalf of the client Product Name LED Warehouse Light Part No WL80W14S, WLl00W14S, WLl20Wl4S, WLl40W14S, WLl50Wl4S ' WL180Wl4S, WL200W14S, WL250Wl4S Sample Received Date May. 22, 2014 Testing Period May. 22, 2014 to Jun. 12, 2014 Test Requested 1. As specified by client, to screen Lead(Pb), Cadmium(Cd), Mercury(l-lg), Chromium(Cr) and Bromine(Br) in the submitted sample(s) by XRF. 2.As specified by client, when screening results exceed the XRF screening limit in IEC 62321-3-112013 Ed. 1 .0, fiJrther use of chemical methods are required to test the Lead(Pb), Cadmium(Cd), Mercury(Hg), Hexavalent Chromium(Cr(VI)), Polybrominated Biphenyls(PBBs), Polybrominated Diphenyl Ethers(PBDEs) in the submitted samples. Test Result(s) Please refer to the following page(s). Test Method Please refer to the following page(s). Tested by 8. L Reviewed by Vie -Q‘7£“' Date Jun. 12 2014 Danny Liu Technical Manager No. R 107848300
  2. 2. CLUIFL 7[L‘l'l‘j17lT[7lltTlQ‘. l4L cf 1.: inn is in Test Report Report No. SCL0lG006l77 Page 2 of 9 Photo(s) of the Product(s) LED Warehouse Light 012145573! Ittzultlsuliiltl uzznaazsnzvn 10 20 / T‘; :-t. .. u. CLNIRL ll_5l| l~l(: ‘: ll-lILR"lAllON0-IL CU}-3l’Ul-! Al| U'x| dc-‘l G7F. f.—113 ‘ifil/ [l. i «tn III lam. I-A xw: I (’l. .l ‘Ill. -II‘ 1'-'1 ‘II-L»"I («HI l'. ':wrIm‘m". v'l| 'l"l")1 dv‘t‘. ’-iv C1.l I. '.oI*FT. .r2Ct"‘I rs um Hm. I HI: I / v*'v". .~.
  3. 3. Test Report Report No. SCL0lG006l77 Page 3 of9 Test Result(s) Sample Sample XRF Chemical Test No. Description Screening Test (mg/ kg) BL 1 Silvery metal Cr(Cr(VI) ) Br(PBBs&PBDEs) Pb Cd 2 Silvery metal Hg Cr(Cr(VI) ) Br(PBBs&PBDEs) Pb Cd 3 Blue coating Hg Cr(Cr(VI) ) Br(PBBs&PBDEs) 4 Silvery metal Cr(Cr(VI) ) / Pb BL Cd BL LED 5 Hg BL (Tested as a whole) Cr(Cr(VI) ) BL BL fl BL BL 6 Gray glue Hg BL Cr(Cr(VI) ) BL Br(PBBs&PBDEs) BL
  4. 4. cri Test Report Report No. SCL0lG006l77 Page 4 of9 Test Result(s) Sample Sample _ XRF Chemical Test _ _ Tested Items _ No. Description Screening Test (mg/ kg) BL / 7 Silvery metal Cr(Cr(VI) ) Br(PBBs&PBDEs) Pb 8 Silvery metal Hg Cr(Cr(VI) ) Br(PBBs&PBDEs) Pb Cd 9 White plastic Hg Cr(Cr(VI) ) Br(PBBs&PBDEs) Pb Cd BL 10 Silvery metal BL BL / Pb BL Cd BL 11 Black solid Hg BL Cr(Cr(VI) ) BL BL T- BL BL 12 Silvery metal l-lg BL Cr(Cr(VI) ) BL Br(PBBs&PBDEs) /
  5. 5. cri Test Report Report No. SCL0lG006l77 Note: Remark: -MDL = Method Detection Limit -N. D. = Not Detected (<MDL) -mg/ kg = ppm = parts per million -BL = Under the XRF screening limit —X= The symbol “X” marks the region where further investigation is necessary. Test Method A. Screening test by XRF spectroscopy XRF screening limits in mg/ kg for regulated elements according to IEC 62321-3-1:2013 Ed.1.0 1.The screening results are only used for reference. 2.When conducting the test for PBBs&PBDEs, XRF was introduced to screen Br Exclusively; When conducting the test for Hexavalent Chromium, XRF was introduced to screen Chromium exclusively. Page 5 of 9 Note: -BL = Under the XRF screening limit -OL = Further chemical test will be conducted while result is above the screening limit. —X= The symbol “X” marks the region where further investigation is necessary. -3o= The reproducibility of analytical instruments —LOD= Detection limit Limit ofIEC 62321-3-1:2013 Ed. l.0 (unitzmg/ kg) MDL Element other Polymers and metals Composite material Polymers _ material Pb BL$(700-30) <X <(1300+3o) BLS(500-3o)<X <(l500+3c) 10 mg/ kg 50 mg/ kg $OL <OL < _ < _ Cd BL(70 3c; )<O): <(130+3o) LOD(50 <(150+3o) 10 mg/ kg 50 mg/ kg Hg BL$(700-3o)<X <(l300+3o) BL<(500-3o)<X <(1500+3c) 10 mg/ kg 50 mg/ kg SOL £OL Cr BL$(700-3o)< X BL<(500-3o)< X 10 mg/ kg 50 mg/ kg Br BL<(300-3cs)< X BL<(250-3cs)< X 10 mg/ kg 50 mg/ kg
  6. 6. cri Test Report Report No. SCL0lG006l77 Page 6 of9 B. Chemical Test Measured Tested ltem(s) Test Method _ MDL Equipment(s) IEC 62321-522013 Ed. l.0 ICP-OES 2 mg/ kg Lead (Pb) Refer to IEC 62321-5:20l3 Ed. l.0 ICP-OES 2 mg/ kg _ IEC 62321-5:2013 Ed. l.0 ICP-OES 2 mg/ kg Cadmium (Cd) Refer to IEC 62321-522013 Ed. l.0 ICP-OES 2 mg/ kg IEC 62321-4:20l3 Ed. l.0 ICP-OES 2 mg/ kg Mercury (Hg) Refer to IEC 62321-4:20l3 Ed. l.0 ICP-OES 2 mg/ kg , IEC 6232122008 Ed. l UV-Vis / Hexavalent Chromium Cr( VI) IEC 6232122008 Ed.1 UV-Vis 2 mg/ kg Polybrominated Biphenyls (PBBS) IEC 62321 22008 Ed. l GC-MS 5 mg/ kg Polybrominated Diphenyl Ethers IEC 6232122008 Ed. l GC-MS 5 mg/ kg (PBDEs) Test Process l). Test for Pb/ Cd Content Non-plating samples Weigh Sfgliapileegsrg place it M Add digestion reagent 2; Digest the sample Dry Ashingl Alkali Fusion/ Analyzed by Acid Dissolution ICP-OES Make up with deionized water Plating samples Take out the substrate afier Take a pomon of the plating had been Z? Add digestion reagent Z? the sample Analyzed by ICP-OES Make up with deionized water dissolved flask Transfer the plating digestive solution into a volumetric
  7. 7. cri Test Report Report No. SCL0lG006l77 Page 7 of9 2). Test for Hg Content Non-plating samples Weigh sample and place it in a . . Digest sample in microwave microwave digestion vessel 1’ Add digestion reagent ’ digestion oven Alkali Fusion/ Acid Dissolution - - Analyzed by Make up with ICP-OES deionized water Plating samples Weigh Sample and _ High-temperature place it in a Crucible 1> Add assistant reagent 1> processing M k 'th - - - Analyzed by ICP_0ES .3 “’—UP W1 Dissolve with appropriate deionized water acid 3). Test for Chromium(VI) Content Non-metal samples Weigh Sample and place Heat at 90-95°C for 3 hours it in a conical flask Add test solution Cool and filter Adjust the pH_value 2, Make up with Z, Analyzed by UV_/ ls of the solution deionized water Add digestion solution Adjust the pH value of the solution
  8. 8. cri Test Report Report No. SCL0lG006l77 Page 8 of9 Plating/ Metal samples Take a portion Of Extracted with Filter and remove the sample boiling water the Sample Adjust the pH value Analyzed by UV-VlS Add test solution . of the solution 4). Test for PBBs/ PBDEs Content Weigh sample and Extracted with _ _ . _ Concentrate the extract place it in a thimble organic solvent Make up with Transfer the extract into a Analyzed by GC-MS _ _ organic solvent volumetric flask
  9. 9. c1'° tssiliiesii CFBNTRE TE illllfi lHl‘EfiHiilCIHAL Test Report Report No. SCL0lG006l77 Page 9 of 9 Photo(s) of the tested component(s) *** End ofReport *** The test report is effective only with both signature and specialized stamp. The result(s) shown in this repoit refer only to the sample(s) tested. Without written approval of CTI, this report can’t be reproduced except in full. Hn, ~.l. u.- CENTRE IESIING INIERNATIONAL CORPORATION 3400-G788-J33 (I: iii| i.-I'viIiIli'i-i| l II‘I'h. *1-‘. 'l'. ‘$E'IH1.‘[1II (IZJ1lIl. il'ri| l|ll‘-‘llHl. (!tZl‘1|)l. -111 I’-‘Dill! -Ii-! ll. l§llll l'~-FnsiI'inl. "-. "'. ‘.v: '.li-Fserl rn"i 'w'ww. cti—cen. com

×