 In substation, Transformer is the most
efficient and costly equipment. So in order
to protect from faults, Transformer o...
 Dissolved Gas In Oil Analysis (Most famous
and Required Test)
 Screen tests
 Water Content
 Metals - In – Oil
 Polyc...
Small samples of oil are taken for
this test, using a clean, moisture -
free, gas- tight container – usually a
ground – gl...
Non Combustible Gases Combustible Gases
 Oxygen
 Nitrogen
 Carbon Dioxide
 Hydrogen
 Methane
 Carbon Monoxide
 Etha...
 Assesses the Internal condition of
transformer
 Helps to calculate the probability of failure
and end of life.
 Identi...
i. Insulation overheating/overloading
ii. Insulation liquid overheating
iii. Partial discharge (Corona)
iv. Arcing in the ...
 The paper insulation which is normally used to insulate
the windings of a transformer is a cellulose product.
 If a tra...
 Overheating of the liquid insulation is slightly different
problem in transformers.
 DGA test will indicate high therma...
 Corona is considered to be a
partial discharge and occurs at
areas of high electrical stress,
such as at sharp points al...
 Corona is indicated in a DGA by indications
of Elevated Hydrogen.
 If corona is detected by a DGA test, other
methods o...
 Arcing is the most severe condition in a
transformer because it indicates a breakdown of
the insulation.
 The presence ...
 Arcing can be generated in many areas of a
transformer.
 Insulation breakdown in the windings from coil
to coil or coil...
Hydrogen (H₂) , Methane(CH₂) , Acetylene (C₂H₂) Ethylene(C₂H₄),
Ethane (C₂H₆), Carbon Monoxide(CO), Carbon Dioxide(CO₂), T...
 Condition 1 - TDCG below this level indicates
the transformer is operating satisfactorily
 Condition 2 - TDCG within th...
 The Dissolved Gas Analysis (DGA) is a
chemical test rather than an electrical test.
It does not suffer from electrical
i...
Dissolved Gas Analysis in Transformer Oil
Dissolved Gas Analysis in Transformer Oil
Dissolved Gas Analysis in Transformer Oil
Prochain SlideShare
Chargement dans…5
×
Prochain SlideShare
Dissolved gas analysis of power transformer oil
Suivant
Télécharger pour lire hors ligne et voir en mode plein écran

21

Partager

Télécharger pour lire hors ligne

Dissolved Gas Analysis in Transformer Oil

Télécharger pour lire hors ligne

Transformer Oil Testing

Dissolved Gas Analysis in Transformer Oil

  1. 1.  In substation, Transformer is the most efficient and costly equipment. So in order to protect from faults, Transformer oil testing is required.  The transformer’s fluid not only serves as a heat transfer medium, it also a part of transformer’s insulation system.  It is therefore prudent to periodically perform tests on the oil to determine whether it is capable of fulfilling its role as an insulant.
  2. 2.  Dissolved Gas In Oil Analysis (Most famous and Required Test)  Screen tests  Water Content  Metals - In – Oil  Polychlorinated Biphenyl (PCB) Content
  3. 3. Small samples of oil are taken for this test, using a clean, moisture - free, gas- tight container – usually a ground – glass 50 ml syringe. It is very important that a DGA sample is kept air tight; otherwise the gases that are dissolved in the liquid can escape into the atmosphere, or external gases can be admitted, which would invalidate the test results. The syringe is sent to laboratory for gas extraction and analysis. Gases are extracted from the oil with a vacuum pump and the gases are identified using gas chromatography.
  4. 4. Non Combustible Gases Combustible Gases  Oxygen  Nitrogen  Carbon Dioxide  Hydrogen  Methane  Carbon Monoxide  Ethane  Ethylene  Acetylene  Propylene  Propane
  5. 5.  Assesses the Internal condition of transformer  Helps to calculate the probability of failure and end of life.  Identifies degradation of insulation before failure of the life.  Low cost test process  As the name implies, this test analyzes the type and the quantity of gases that are dissolved in the transformer oil.
  6. 6. i. Insulation overheating/overloading ii. Insulation liquid overheating iii. Partial discharge (Corona) iv. Arcing in the transformer
  7. 7.  The paper insulation which is normally used to insulate the windings of a transformer is a cellulose product.  If a transformer becomes overloaded for any reason, the windings will generate more heat and deteriorate the cellulose insulation.  The DGA test can identify an overloaded transformer by a test result showing high carbon monoxide, high carbon dioxide, and in extreme cases, even elevated methane and ethylene is found.  If a transformer is overloaded for a long period of time, the deteriorating condition of the cellulose will shorten the life of the transformer.
  8. 8.  Overheating of the liquid insulation is slightly different problem in transformers.  DGA test will indicate high thermal gases (methane, ethane and ethylene) as a result of overheating of the liquid.  These gases are formed from a breakdown of the liquid caused by the heat.  Heating may be caused due to the following effects:- 1. Poor contacts on a tap changer. 2. Loose connections on a busing or a grounding strap. 3. Circulating currents in the core due to an unintended core ground.
  9. 9.  Corona is considered to be a partial discharge and occurs at areas of high electrical stress, such as at sharp points along an electrical path.  Partial discharge is commonly explained as being intermittent unsustained arcs which are sort off of the conducting material like a stream of electrons.  These arcs contact solid insulating material will cause severe damage to the equipments.  When corona occurs the Transmission Lines becomes Violet Bluish in color due to the ionization of elections.
  10. 10.  Corona is indicated in a DGA by indications of Elevated Hydrogen.  If corona is detected by a DGA test, other methods of pin-pointing the exact location of the problem can be used – a partial discharge detector can be used to detect the exact place where corona is making the hissing noise.
  11. 11.  Arcing is the most severe condition in a transformer because it indicates a breakdown of the insulation.  The presence of Acetylene is an indicator of arcing; and even low levels of this gas should cause concern.  Normally, arcing occurs only after other problems which are detected by the DGA testing. However, the high energy required to produce an arc will cause all combustibles to be elevated.  If the arc occurs in the area of cellulose insulation, carbon dioxide and carbon monoxide also will be elevated.
  12. 12.  Arcing can be generated in many areas of a transformer.  Insulation breakdown in the windings from coil to coil or coil to ground, will result in arcing. A portion of the insulation may deteriorate until it can no longer contain the stress of the electrical conductor.  If a winding shorts from turn to turn, or phase to phase, or phase to ground, arcing will occur and the transformer will fail.  When arcing occur in the area of the windings, the usual result is de-tanking of the transformer, and a rewind conducted.  A loose connection also may cause arcing, but of greater significance would be arcing due to insulation breakdown.
  13. 13. Hydrogen (H₂) , Methane(CH₂) , Acetylene (C₂H₂) Ethylene(C₂H₄), Ethane (C₂H₆), Carbon Monoxide(CO), Carbon Dioxide(CO₂), Total Dissolved Combustible Gas(TDCG) Status H₂ CH₂ C₂H₂ C₂H₄ C₂H₆ CO CO₂ TDCG Condition 1 100 120 35 50 65 350 2500 720 Condition 2 101- 700 121- 400 36-50 51-100 66-100 351-570 2501-4000 721-1920 Condition 3 701- 1800 401- 1000 51-80 101-200 101-150 571- 1400 4001- 10000 1921-4630 Condition 4 >1800 >1000 >80 >200 >150 >1400 >10000 >4630 Dissolved Gas Concentrations Limits (ppm)
  14. 14.  Condition 1 - TDCG below this level indicates the transformer is operating satisfactorily  Condition 2 - TDCG within this range indicates greater than normal combustible levels & should prompt additional investigation. (any gas exceeding specified levels)  Condition 3 - TDCG within this range indicates high level of decomposition (additional investigation required)  Condition 4 - TDCG within this range indicates excessive decomposition. Continued operation could result in failure of the transformer.
  15. 15.  The Dissolved Gas Analysis (DGA) is a chemical test rather than an electrical test. It does not suffer from electrical interference and can be done without de - energization of the transformer. The cost of each DGA is relatively inexpensive.  All these factors make DGA a powerful tool in the preventive maintenance of transformer.
  • DhanashriSonkamble

    Apr. 30, 2021
  • OmerAhmedObeidSalih

    Feb. 3, 2021
  • NaushadKhan17

    Nov. 19, 2020
  • ShivangiSoni20

    Oct. 23, 2020
  • Kamaljitkumar2

    Jun. 14, 2019
  • AttaAtta2

    Mar. 31, 2019
  • Dheerajdc

    Oct. 24, 2018
  • ShandyHarryMulyono

    Oct. 19, 2018
  • DEBBYPERKASA

    Oct. 16, 2018
  • AmirGul4

    Jul. 30, 2018
  • ambujkumarmandal

    Apr. 27, 2018
  • ambujkumar12935756

    Apr. 27, 2018
  • EddiePhiri

    Jan. 13, 2018
  • arsilvahoraa

    Nov. 24, 2017
  • HerbertDeGuzman

    Oct. 18, 2017
  • MonikaBehera1

    Sep. 15, 2017
  • h3nd12y

    Apr. 29, 2017
  • mayankparmar277

    Mar. 28, 2017
  • dhanrajchavan4

    Mar. 22, 2017
  • Gprulz

    Mar. 6, 2017

Transformer Oil Testing

Vues

Nombre de vues

8 225

Sur Slideshare

0

À partir des intégrations

0

Nombre d'intégrations

102

Actions

Téléchargements

852

Partages

0

Commentaires

0

Mentions J'aime

21

×